A250 3
A250 3
A250 3
3-2007 (R2011)
Revision of ANSI A250.3-1999
ANSI/SDI A250.3-2007
STEEL
DOOR
INSTITUTE
SPONSOR
ANSI/SDI
A250.3-2007 (R2011)
Revision of
ANSI/SDI A250.3-1999
Secretariat
American
National
Standard
Published by
Contents
Page
Foreword............................................................................................. ii
1 General..........................................................................................1
1.1 Scope......................................................................................1
1.2 Reference Documents..............................................................1
2 Material. . ........................................................................................1
3 Testing...........................................................................................2
3.1 Salt spray test. . ........................................................................2
3.2 Condensation testing (humidity)...............................................2
3.3 Accelerated weathering test.....................................................2
3.4 Impact test...............................................................................2
3.5 Film adhesion test....................................................................2
3.6 Abrasion test............................................................................2
4 Acceptance criteria........................................................................2
4.1 Salt spray resistance................................................................2
4.2 Condensation resistance..........................................................3
4.3 Accelerated weathering resistance...........................................3
4.4 Impact test...............................................................................3
4.5 Film adhesion...........................................................................3
4.6 Abrasion resistance..................................................................3
5 Report.. ..........................................................................................3
6 General..........................................................................................3
6.1 Testing laboratory. . ...................................................................3
6.2 Certification. . ............................................................................3
Tables
1 Rust grades...................................................................................4
2 Classification of adhesive test results............................................8
Figures
1 Visual reference for percentage of rust.. .........................................4
2 Blister size #2 . . .............................................................................5
3 Blister size #4 . . .............................................................................5
4 Blister size #6 . . .............................................................................6
5 Blister size #8 . . .............................................................................6
6 Photographic reference standard for degree of chalking ...............7
ii
iii
ANSI/SDI A250.3-2007
2 Material
ASTM G154-04, Standard Practice for Operating Fluorescent Light Apparatus for UV
Exposure of Nonmetallic Materials.
ANSI/SDI A250.3-2007
UV-Condensation Exposures of Paint and Related Coatings For a test period of 300 hours
duration. The cycle schedule for operating this
type of equipment shall be 18 hours of light
exposure at 140F (60C) followed by a 6 hour
condensation cycle at 120F (49C).
3 Testing
The coating shall be tested per ASTM D279493(2004), Standard Test Method for Resistance
of Organic Coatings to the Effects of Rapid
Deformation (Impact), with 20 inch pounds of
direct impact using a Gardner Impact Tester with
a 1/2" (12.7 mm) diameter ball or punch at room
temperature of 70-75F (21C-24C). The test
specimen shall be impacted at three locations
on the panel that have a dry film thickness within
the tolerance range for the coating process.
Apply one-inch (25.4 mm) wide, #600 Scotch
cellophane pressure-sensitive tape firmly to the
impact area and pull off sharply.
4 Acceptance criteria
a) Apparatus The apparatus used for accelerated weathering testing shall be of such
design as to conform to ASTM G154-04,
Standard Practice for Operating Fluorescent
Light Apparatus for UV Exposure of Nonmetallic Materials. The bulb type used shall be a
UVA340.
ANSI/SDI A250.3-2007
6 on each side of the scribe line when evaluated in accordance with ASTM D1654-92 and
rated per ASTM D1654-92, Table 1. Rating of
Failure at Scribe (Procedure A).
4.2 Condensation resistance
The coating film shall be allowed to exhibit the
dense pattern of #8 blisters, but shall have no
more than the few pattern of #6 blisters as
illustrated in the photographic reference ASTM
D714-02, Standard Test Method for Evaluating Degree of Blistering of Paints. Testing
shall be in accordance with Paragraph 3.2.
Visual representations of the various degrees
of blistering are shown in Figures 2 through 5
of this document.
4.3 Accelerated weathering resistance
When tested in accordance with Paragraph
3.3 herein, the paint film shall exhibit the following traits:
4.3.1 No rust, checking, cracking, erosion or
flaking shall be present.
4.3.2 No more than a few #6 blisters as illustrated in Figure 4 and in ASTM D714-02,
Standard Test Method for Evaluating Degree
of Blistering of Paint.
4.3.3 A degree of chalking not to exceed #8
as illustrated in Figure 6 and in test method
B of ASTM D4214-98, Standard Test Method
for Evaluating Degree of Chalking of Exterior
Paint Films.
5 Report
5.1 The report shall cover the date the test was
performed and the issue date of the report.
5.2 Identification of the specimen tested,
source of supply, manufacturer, model or series number, or both, and any other pertinent
information.
5.3 A detailed description of the specimen
or specimens tested shall include the type of
prime or barrier coating if used, the method
of coating application, the procedure used to
cure it and the dry film thickness.
5.4 Any modifications made on the test specimen to obtain the values of acceptance shall
be noted and described.
5.5 A statement that the test or tests were
conducted in accordance with the methods
and procedures as specified herein. If deviations from these methods and procedures were
made, they shall be described in the report.
6 General
ANSI/SDI A250.3-2007
10
00.01
00.03
00.10
00.30
01.00
03.00
10.00
16.67
33.33
50.00
100.00
MEDIUM
MEDIUM
FEW
FEW
MEDIUM DENSE
MEDIUM DENSE
DENSE
DENSE
ANSI/SDI A250.3-2007
6
MEDIUM
MEDIUM
FEW
FEW
MEDIUM DENSE
MEDIUM DENSE
DENSE
DENSE
ANSI/SDI A250.3-2007
ANSI/SDI A250.3-2007
ANSI/SDI A250.3-2007
Classification
5B
Rate of adhesion
None
4B
3B
2B
1B
0B
MEMBERS OF THE
STEEL DOOR INSTITUTE
AVAILABLE PUBLICATIONS
Specifications
ANSI/SDI A250.6 Recommended Practice for Hardware Reinforcings on Standard
Steel Doors and Frames
ANSI/SDI A250.8 SDI 100 Specifications for Standard Steel Doors & Frames
SDI-108
SDI-118
SDI-128
SDI-129
Test Procedures
ANSI/SDI A250.3 Test Procedure & Acceptance Criteria for Factory Applied Finish
Coatings for Steel Doors & Frames
ANSI/SDI A250.4 Test Procedure & Acceptance Criteria for Physical Endurance for
Steel Doors, Frames and Frame Anchors
ANSI/SDI A250.10 Test Procedure & Acceptance Criteria for Prime Painted Steel
Surfaces for Steel Doors & Frames
ANSI/SDI A250.13 Testing and Rating of Severe Windstorm Resistant Components
for Swinging Door Assemblies for Protection of Building Envelopes
(Not applicable for FEMA 320/361 or ICC-500 Shelters)
SDI-113
SDI-131
Construction Details
ANSI/SDI A250.11 Recommended Erection Instructions for Steel Frames
SDI-110
SDI-111
SDI-122
Miscellaneous Documents
SDI-112
SDI-117
SDI-124
SDI-127
SDI-130
SDI-134
Ceco Door
9159 Telecom Drive
Milan, TN 38358
(731) 686-8345
www.cecodoor.com
Curries
P.O. Box 1648
Mason City, IA 50402-1648
(641) 423-1334
www.curries.com
Deansteel Manufacturing Co.
931 S. Flores Street
San Antonio, TX 78204-1406
(210) 226-8271
www.deansteel.com
DOOR COMPONENTS INC.
7980 Redwood Avenue
Fontana, CA 92336-1638
(909) 770-5700
www.doorcomponents.com
HOLLOW METAL XPRESS
602 S. 65th Avenue
Phoenix, AZ 85043
623-936-7000
www.HMXpress.com
Mesker Door, Inc.
3440 Stanwood Boulevard
Huntsville, AL 35811-9021
(256) 851-6670
www.meskerdoor.com
MPI
319 North Hills Road
Corbin, KY 40701
(606) 523-0173
www.metalproductsinc.com
Pioneer Industries, Inc.
171 South Newman Street
Hackensack, NJ 07601
(201) 933-1900
www.pioneerindustries.com
Republic Doors & Frames
155 Republic Drive
McKenzie, TN 38201-0580
(731) 352-3383
www.republicdoor.com
Security Metal Products
5700 Hannum Avenue, Suite 250
Culver City, CA 90230
(310) 641-6690
www.secmet.com
Steelcraft
9017 Blue Ash Road
Cincinnati, OH 45242
(513) 745-6400
www.steelcraft.com