INTRODUCTIONThe pellet stove is a heating device with internal combustion that take the air from the room
and transform it into hot air.
The heat process is generated by the fuel (the pellet) and combustion (the air)which combination result as:
1)
Energy, the flame, consequently heat
2)
Combustion residue that is not transformed in energy, the ash
To optimize the production of the energy, we should know the chemical composition of the pellet wood and consequently calculate the volume of air requested to burn it, optimizing the combustion. This ratio is called stoichiometric
ratio.
As much as closer we can get the stove working with the ideal stoichiometric ratio, compared to the chemical composition of the pellet, the better is the combustion and the production of energy .
WHAT IS THE RDS TECHNOLOGY AND HOW IT WORKS !?
The RDS system gives the possibility to the stove to constantly control the volume of air requested for the combustion, in relation to the ideal stoichiometric ratio preset by us.
The system adapts itself to different working conditions such as:
-
Different wood pellet quality : the stoichiometric ratio change, the RDS system feel the different requirement
of air and order the stove to reset the preset ratio
-
Different size of the chimney : the stoichiometric ratio change, the RDS system feel the different requirement
of air and order the stove to reset the preset ratio.
With the RDS system, the stoves is always working with the ideal efficiency, adapting itself to different condition of
combustion air and the chemical composition of pellet .
Is the instrument that can measure the flow of air requested for the combustion. Connected to an electronic device,
measuring the speed of the air, it can adjust the correct volume of air requested for the combustion of the stove.
There are two temperature sensors; a simple one (sensor A) and a second one , similar to the first one, but preheated
(sensor B).
The temperature values detected by the two sensors are different.
The sensor A feel the room temperature, while the sensor B, feel the temperature of the preheated sensor.
Placing the two sensors of the flow meter in a tube where a flow of air is passing, the temperature of the sensor B
will reduce depending from the speed of the air passing inside the tube; values change depending from the speed of
the air passing inside the tube.
The main electronic board can detect the temperature modification of the two sensors and can calculate the speed of
the air accordingly.
If we multiply the value by the diameter of the tube, you will get the flow of air in m3/s passing through the system. In
a volume (m3) there is a specific mass of air; multiplying this value for the flow of air, we can obtain the mass of air
entering in the combustion chamber of the stove.
Capitolo
Pagina
2
1
Cold ignition (t. smokes <= then the switch off parameter TF15 )
Hot ignition or restart (t. smokes > lower then switch off parameter TF15)
OK
-If the temperature of the smokes is higher than the parameter TF15 (Tsmoke >TF15),the stove continue the cleaning
phase.
-if the temperature of the smokes is less or equal off threshold (Tsmoke >=TF15) , a TF45 timer is activated (REIGNITION BLOCK) THE DISPLAY SHOWS FAN WAITING IGNITION: at the end of this time, the stove goes on
IGNITION phase.
IMPORTANT : the above-mentioned timer (TF45) has been introduced in order to guarantee that
there is no flame or unburned pellet inside the fire pot before the stove switch on.
DISPLAY SHOWING START : in his phase the ignitor is pre-heated for a preset time, connected to parameter TF 04. In this phase, the loading of the pellet starts according to TF01,
DISPLAY SHOWING WAITING FLAME : in this phase, while the ignitor is still workings, loading of the
pellet continue, the smoke fan starts and the flow meter starts to measure the flow of combustion air passing from the firepot and set the air volume as per the value TF 03 (the rpm of the smoke fan varies in order
to keep a constant the volume of air). In this moment, the T0 value is memorized as a reference to read the
smoke temperature increase (TF05 DELTA FLAME) and determine later the stove to pass into phase FLAME LIGTH. The loading of the pellet is regulated by TF01 which indicates the ON values of the gearmotor.
To prevent a surplus of pellet into the firepot, we activated a parameter TF02 that limit the loading time of the
pellet during all start up procedure.
Capitolo
Pagina
2
2
NB. : If in the working time set for the auger to feed the pellet (TF 02), the motherboard read an increase of
temperature equal to the value set in the parameter TF 05, the stove pass from the phase WAITING FLAME
Into the phase FLAME LIGTH, without considering this time.
NB.: if the motherboard does not feel an increase of temperature equal to the value set in TF05 within the
time of time out (TF 48), the stove pass into NO INGNITION ALARM.
B) Flame stabilization phase
DISPLAY SHOWING FLAME LIGTH : in this phase the ignitor goes automatically in OFF status; the flow of
air goes at a value set by parameter TF10. The functioning of the auger is set by parameter TF08 the flame
has few minutes (TF09) to get stabilized.
During this working phase, which duration is measured in minutes (TF09), a check is done on smoke temperature. The system memorize the smoke temperature T0 at the beginning of this phase.
Then, every one minute, a test is done to be sure that the smoke temperature increase regularly; in the contrary, the display will show AL11 WRONG FLAME.
C WORKING PHASE
DISPLAY SHOWING WORK : the stove perform all power from PT01 to PT05 and then goes to working power set by the customer, while the heat exchanger, if the parameter TF 06 fan threshold is achieved,
It goes to the working speed set by the customer.
When the stove reaches the working phase , reaching the preset power, the air flow and the auger operate
according to parameters set for the working power selected (TF 17 TF 20 TF23 TF 26 TF 29) for the air,
TF16 TF19 TF 22 TF 25 TF 28 for the auger, TF 18 - TF 21 TF 24 TF 27 TF 30 for the heat exchanger)
Each time a working power is modified, the stove reaches the set power increasing or decreasing stepless,
the power as follow:
DECREASE IN POWER
INCREASE IN POWER
Power
Time
Power
Time
from P5 to P4
40
from P1 to P2
40
from P4 to P3
40
from P2 to P3
40
from P3 to P2
40
from P3 to P4
40
from P2 to P1
40
from P4 to P5
40
If, during the work phase, the smoke temperature reaches the maximum threshold (TF 42) the stove goes into ventilation
to reduce the smoke temperature. If the ventilation is not sufficient and the temperature continues to increase, reaching
269 C/ 516 F the stove automatically goes into SMOKE OVER TEMPERATURE ALARM.
If the switchboard indicates a constant decrease in temperature due to extinction of the flame, the stove goes to NO
PELLET ALARM reaching the threshold set in the parameter TF 41 (NO PELLET THRESHOLD) .
IMPORTANT!!! Even if the smoke temp. reaches the value set in the TF 06, the exchanger does not switch on
until the stove goes to WORK mode; this condition is necessary in order to avoid jumps in the Tsmoke in
FLAME LIGHT, with the risk of displaying an unusual AL 11 FLAME ANOMALY ALARM.
THE DISPLAY SHOWS FIRE POT CLEANING: in this phase the stove cleans the fire pot according to the interval between cleaning operations of TF 13. The duration of each cleaning operation is regulated by the parameter TF 12. The smoke extractor turns according to the TF 14 settings with a pellet load of TF 11.
The purpose of this function is to prevent the basket from clogging when the stove remains in operation for
many hours during the day.
Debimetro
OFF
OFF
OFF
ON
OFF
ON
T. C
TF04
TF04
TF01
TF48
TF31
TF01
TF02
TF32
TF05
(Fase A-B-C)
TF09
TF08
Accensione
TF18,21,24,27,30
TF17,20,23,26,29
TF16,19,22,25,28
Pagina
2
3
Capitolo
Pagina
2
4
D- Modulation phase
THE DISPLAY SHOWS MODULATION WORK: when the set room temperature is reached, independently
from the working power of the stove, it goes to working power 1.
E - Comfort clima
To activate the comfort clima please set a value different from OFF using
keys 1 and 2. Then confirms with OK.
Set the time during which the stove should stay in MODULATION WORK
before going into ECO STOP (default 4).
The set value (in this case 5C) has activated the function Comfort Clima.
FUNCTIONING:
The value control the restart temperature of the stove.
EXAMPLE:
-
Room temperature set at 21C.
-
Comfort clima value set at 5C.
With this regulation the stove will switch off once reached the 21C and
will switch on when the room temperature is 15C (21C-5-0,5 tolerance =
approximately 15C). on the display will appear the lines as in the picture
on the left.
The modulation phase is activated because the set room temperature has
been reached. If this temperature is keep for the set time of DELAY COMFORT CLIMA the stove switch off.
After the switching off phase the writing ECO STOP will appear on
the display. The stove will remain in this status until decrease to
15C, only at that time the starting phase will begin.
REMARK: the functioning of the stove with COMFORT CLIMA mode could activate the ignition and the
switching off phase several times during the day; this could compromise the duration of the candle for the
automatic ignition of the stove.
Capitolo
Pagina
2
5
TF46
FINAL CLEANING
OFF
OFF
TF 15
SMOKE
TEMPERATURE
OFF
ON
SMOKE ENGINE
ON
ON
WORK
STOVE
CONDITIONS
GRAFICO SPEGNIMENTO
OFF
Capitolo
Pagina
2
6
N.B. : the value relating to the restart threshold is a datum tested in the company on each of our stove models in
order to identify the optimal restart condition. This parameter should not be changed significantly by the service
centre (not over 5 C/10 F) unless Ecoteck technical centre has been consulted.
IMPORTANT!!!This method makes it possible to solve the problem with the smoke extractor, which, passing
from the OFF phase to the activation phase, could cause an anomalous increase in temperature which could
elude the TF05 FLAME DELTA when a flame is present.
N.B . : For all the other phases, the stove behaves in the same operating way as a normal ignition (See paragraph 1.2.1 from point B).
Debimetro
OFF
0000
2700
OFF
ON
OFF
ON
T. C
Estrattore
alla velocit
massima
TF32
TF04
TF04
TF01
TF48
TF31
TF01
TF02
Riaccensione
TF09
TF32
TF08
TF05
TF18,21,24,27,30
TF17,20,23,26,29
TF16,19,22,25,28
Pagina
2
7
Capitolo
Pagina
3
1
The innovation of this particular display is the communication through low voltage conveyed waves (12 volts) between the electronic motherboard and the display. The communication is made trough a bipolar cable (ex: the cable for the stereo speakers) and the novelty is the
possibility to install the display in the wall using the optional standard frame for electrical box 503.
3.1. Display with mode BASE
Calendario
Orologio
Potenza di lavoro
Temperatura ambiente
Stato stufa
Fig. 1
Fig. 2
Capitolo
Pagina
3
2
Confermare con il tasto OK due volte mantenendo deselezionata la casella (flag, vedi fig. 2) Sonda Consolle.
Al raggiungimento della temperatura, sul display verr visualizzata la scritta LAVORO MODULA, in questo caso la stufa ridurr al minimo
il consumo dei pellet diminuendo la potenza di riscaldamento.
MODE WITH ROOM SENSOR INTEGRATED TO THE DISPLAY
in case you want to install the display on the wall instead of on the stove as from the factory, please reference to the functioning with
supplied room sensor (as above explicated) with just one difference: the box (flag) SENSOR CONSOLLE, if you work in this mode,
should be selected by using key 2. Then confirm with the key OK ( reference ti
o pic. 1 paragraph 7.1.2.)
MODALITA TERMOSTATO ESTERNO
if you use an external thermostat correctly connected as shown in the electrical scheme ( reference paragraph 10), the display will not show
the room temperature but the writing T ON ( when the contact is closed) or T OFF ( when the contact is open).
REMARK: TO ENABLE THE EXTERNAL THERMOSTAT ENTER IN THE SET TEMPERATURE USING KEY 1 AND THEN PRESS REPEATEDLY TO REACH THE VALUE EST ON THE DISPLAY; CONFIRM TWO TIMES WITH THE KEY OK KEEPING DESELECTED THE
BOX (FLAG) SENSOR CONSOLLE.
Once reached the set temperature of the thermostat the display will show MODULATION WORK, so the stove will reduce to minimum the
pellet consumption and the power as well. If activated the mode COMFORT CLIMA, the stove will switch on and off automatically (for details
reference paragraph 8.2.)
N.PEL.
N.H2O
N.AMB. TERM.
N.AMB. TERM.
-TC1+
Nero
Nero
Rosso
Blu
SONDA
AMBIENTE
-TC1+
9
10
REMARK: if you want to use the CONFORT CLIMA is advisable an external thermostat with OFF-SET of at
least 3C.
3.1.3. set of the working power
To modify the working power press key 2 to enter in the dedicated menu and with keys 1 and 2 to set the power you desire from 1 to 5
and confirm with key OK. Increasing the power also the pellet consumption and the speed of the fan increase as well.
It is not possible to modify the set power during the phase of MODULATION WORK.
3.2. Display with mode ADVANCED
Calendario
Orologio
Potenza di lavoro
Temperatura ambiente
Stato stufa
Key OK: access key to the complete menu and confirmation of the settings chosen
Key 1: scroll key and modification of the settings
Key 2: scroll key and modification of the settings
The stove is equipped with many functions available in each menu programming. Some of these menu are accessible for the end user ,
other are protected with a password so they are accessible only for the After sales center.
Capitolo
Pagina
3
3
The three pictures which follow show the menu with all its icons for the advanced functionalities
The use of the display in advanced mode provides the view of three main menus:
-USER MENU
-DEFAULT SETTINGS (protected by a password)
-BASIC PARAMETERS (protected by a password)
The submenus of the USER MENU (the only one accessible for the end user) are the following:
-Menu STOVE STATUS
-Menu SET ROOM TEMPERATURE
-Menu SET POWER
-Menu SET CLOCK
-Menu CHRONOTHERMOSTAT
-Menu LANGUAGE
-Menu COMFORT CLIMA
-Mode SILENCE
-Mode SELF CONTROL SYSTEM
-Menu VIEW SETTINGS
-Menu VIEW WORKING HOURS
-Menu SET DRAUGHT/PELLET
3.2.1 Menu STOVE STATUS
In this menu you can check the correct functioning of the most important components of the pellet stove, and some values which distinguish
its correct functioning.
To enter in this menu press 3 times the key OK after having selected the icon with the writing Stove status.
This menu is used both by the after sale center to understand the reason of the malfunctioning of the stove and by the end user as well for
the pellet loading in the tank.
3.2.2. menu SET ROOM TEMPERATURE
To enter in the USER MENU press two times key OK.
To enter in the menu SET ROOM TEMPERATURE press once key 2 and confirm with OK.
TO MODIFY THE SETTING PLEASE REFERENCE TO PARAGRAPH 7.1.2.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
Capitolo
Pagina
3
4
Il simbolo indicato seganla che attiva la funzione crono. E comunque possibile effettuare la
programmazione del crono anche se questo risulta disattivato. Per renderla funzionante fare
riferimento al capitolo dedicato allimpostazione dellorologio (5.2.4 MENU OROLOGIO).
Capitolo
Pagina
3
5
Valori impostabili
Da OFF a 23:50 a step di 10
Da OFF a 23:50 a step di 10
Tra on/off per i giorni da luned a domenica
POTENZA PROG - 1
Da 01 a 05
Da EST a MAN
START PROG - 2
STOP PROG - 2
GIORNO PROG - 2
POTENZA PROG - 2
Da 01 a 05
Da EST a MAN
ESEMPIO:
Suppose that the user want to switch on the stove at 08:30 with set switch off at 21:30 all days of the week with the exception of the weekend
(PROGRAM 1), suppose moreover that the user want a room temperature of 21C and to reach this temperature he sets a working power of
3. The passages to do will be the following:
-
From the MENU CHRONO confirm with key OK and set the program you want to modify using key 1 and 2;
-
By confirming with key OK you go to the set of the switch on hour, set the hour (hh:mm) using keys 1 and 2;
-
By confirming with key OK you go to the set of the switch off hour, set the hour (hh:mm) using keys 1 and 2;
-
By confirming with key OK you go to the scroll of the days, with keys 1 and 2 activate/deactivate the days (ex: Monday, Tuesday,
Wednesday, Thursday and Friday active).
-
By confirming with key OK you go to the set of the power, with keys 1 and 2 set the value (ex: Power 3).
-
By confirming with key OK you go to the set of the room temperature, with keys 1 and 2 set set the degrees (ex: 20C).
When the stove is working and the set room temperature is reached the stove goes into MODULATION or COMFORT CLIAMA (if activated).
! IMPORTANT
Capitolo
Pagina
3
6
Capitolo
Pagina
3
7
Capitolo
Pagina
3
8
! IMPORTANT
Values
from 0 to -5
0
from 0 to 5
Values
from 0 to -5
0
from 0 to 5
REMARK: by each step of modification corresponds variation of 5% on the pellet loading and a variation of
0,05 m/s on the flux exclusively during the working phase (TF 16, TF19, TF 22, TF 25, TF 28 fort the screw
TF 17, TF20, TF 23, TF 26, TF 29 for the flux).
3.3. Automatic loading of the screw
To load automatically the screw (when the stove is new or the loading scew is empty) please do following operations:
Coclea ferma
Coclea attivata
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
Repeat the operation several times until you see the pellet fall into the firepot.
It is possible to do this operation only if the stove is in FINAL CLEANING phase or OFF.
Capitolo
Pagina
3
1
The innovation of this particular display is the communication through low voltage conveyed waves (12 volts) between the electronic motherboard and the display. The communication is made trough a bipolar cable (ex: the cable for the stereo speakers) and the novelty is the
possibility to install the display in the wall using the optional standard frame for electrical box 503.
3.1. Display with mode BASE
Calendario
Orologio
Potenza di lavoro
Temperatura ambiente
Stato stufa
Fig. 1
Fig. 2
Capitolo
Pagina
3
2
Confermare con il tasto OK due volte mantenendo deselezionata la casella (flag, vedi fig. 2) Sonda Consolle.
Al raggiungimento della temperatura, sul display verr visualizzata la scritta LAVORO MODULA, in questo caso la stufa ridurr al minimo
il consumo dei pellet diminuendo la potenza di riscaldamento.
MODE WITH ROOM SENSOR INTEGRATED TO THE DISPLAY
in case you want to install the display on the wall instead of on the stove as from the factory, please reference to the functioning with
supplied room sensor (as above explicated) with just one difference: the box (flag) SENSOR CONSOLLE, if you work in this mode,
should be selected by using key 2. Then confirm with the key OK ( reference ti
o pic. 1 paragraph 7.1.2.)
MODALITA TERMOSTATO ESTERNO
if you use an external thermostat correctly connected as shown in the electrical scheme ( reference paragraph 10), the display will not show
the room temperature but the writing T ON ( when the contact is closed) or T OFF ( when the contact is open).
REMARK: TO ENABLE THE EXTERNAL THERMOSTAT ENTER IN THE SET TEMPERATURE USING KEY 1 AND THEN PRESS REPEATEDLY TO REACH THE VALUE EST ON THE DISPLAY; CONFIRM TWO TIMES WITH THE KEY OK KEEPING DESELECTED THE
BOX (FLAG) SENSOR CONSOLLE.
Once reached the set temperature of the thermostat the display will show MODULATION WORK, so the stove will reduce to minimum the
pellet consumption and the power as well. If activated the mode COMFORT CLIMA, the stove will switch on and off automatically (for details
reference paragraph 8.2.)
N.PEL.
N.H2O
N.AMB. TERM.
N.AMB. TERM.
-TC1+
Nero
Nero
Rosso
Blu
SONDA
AMBIENTE
-TC1+
9
10
REMARK: if you want to use the CONFORT CLIMA is advisable an external thermostat with OFF-SET of at
least 3C.
3.1.3. set of the working power
To modify the working power press key 2 to enter in the dedicated menu and with keys 1 and 2 to set the power you desire from 1 to 5
and confirm with key OK. Increasing the power also the pellet consumption and the speed of the fan increase as well.
It is not possible to modify the set power during the phase of MODULATION WORK.
3.2. Display with mode ADVANCED
Calendario
Orologio
Potenza di lavoro
Temperatura ambiente
Stato stufa
Key OK: access key to the complete menu and confirmation of the settings chosen
Key 1: scroll key and modification of the settings
Key 2: scroll key and modification of the settings
The stove is equipped with many functions available in each menu programming. Some of these menu are accessible for the end user ,
other are protected with a password so they are accessible only for the After sales center.
Capitolo
Pagina
3
3
The three pictures which follow show the menu with all its icons for the advanced functionalities
The use of the display in advanced mode provides the view of three main menus:
-USER MENU
-DEFAULT SETTINGS (protected by a password)
-BASIC PARAMETERS (protected by a password)
The submenus of the USER MENU (the only one accessible for the end user) are the following:
-Menu STOVE STATUS
-Menu SET ROOM TEMPERATURE
-Menu SET POWER
-Menu SET CLOCK
-Menu CHRONOTHERMOSTAT
-Menu LANGUAGE
-Menu COMFORT CLIMA
-Mode SILENCE
-Mode SELF CONTROL SYSTEM
-Menu VIEW SETTINGS
-Menu VIEW WORKING HOURS
-Menu SET DRAUGHT/PELLET
3.2.1 Menu STOVE STATUS
In this menu you can check the correct functioning of the most important components of the pellet stove, and some values which distinguish
its correct functioning.
To enter in this menu press 3 times the key OK after having selected the icon with the writing Stove status.
This menu is used both by the after sale center to understand the reason of the malfunctioning of the stove and by the end user as well for
the pellet loading in the tank.
3.2.2. menu SET ROOM TEMPERATURE
To enter in the USER MENU press two times key OK.
To enter in the menu SET ROOM TEMPERATURE press once key 2 and confirm with OK.
TO MODIFY THE SETTING PLEASE REFERENCE TO PARAGRAPH 7.1.2.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
Capitolo
Pagina
3
4
Il simbolo indicato seganla che attiva la funzione crono. E comunque possibile effettuare la
programmazione del crono anche se questo risulta disattivato. Per renderla funzionante fare
riferimento al capitolo dedicato allimpostazione dellorologio (5.2.4 MENU OROLOGIO).
Capitolo
Pagina
3
5
Valori impostabili
Da OFF a 23:50 a step di 10
Da OFF a 23:50 a step di 10
Tra on/off per i giorni da luned a domenica
POTENZA PROG - 1
Da 01 a 05
Da EST a MAN
START PROG - 2
STOP PROG - 2
GIORNO PROG - 2
POTENZA PROG - 2
Da 01 a 05
Da EST a MAN
ESEMPIO:
Suppose that the user want to switch on the stove at 08:30 with set switch off at 21:30 all days of the week with the exception of the weekend
(PROGRAM 1), suppose moreover that the user want a room temperature of 21C and to reach this temperature he sets a working power of
3. The passages to do will be the following:
-
From the MENU CHRONO confirm with key OK and set the program you want to modify using key 1 and 2;
-
By confirming with key OK you go to the set of the switch on hour, set the hour (hh:mm) using keys 1 and 2;
-
By confirming with key OK you go to the set of the switch off hour, set the hour (hh:mm) using keys 1 and 2;
-
By confirming with key OK you go to the scroll of the days, with keys 1 and 2 activate/deactivate the days (ex: Monday, Tuesday,
Wednesday, Thursday and Friday active).
-
By confirming with key OK you go to the set of the power, with keys 1 and 2 set the value (ex: Power 3).
-
By confirming with key OK you go to the set of the room temperature, with keys 1 and 2 set set the degrees (ex: 20C).
When the stove is working and the set room temperature is reached the stove goes into MODULATION or COMFORT CLIAMA (if activated).
! IMPORTANT
Capitolo
Pagina
3
6
Capitolo
Pagina
3
7
Capitolo
Pagina
3
8
! IMPORTANT
Values
from 0 to -5
0
from 0 to 5
Values
from 0 to -5
0
from 0 to 5
REMARK: by each step of modification corresponds variation of 5% on the pellet loading and a variation of
0,05 m/s on the flux exclusively during the working phase (TF 16, TF19, TF 22, TF 25, TF 28 fort the screw
TF 17, TF20, TF 23, TF 26, TF 29 for the flux).
3.3. Automatic loading of the screw
To load automatically the screw (when the stove is new or the loading scew is empty) please do following operations:
Coclea ferma
Coclea attivata
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
Repeat the operation several times until you see the pellet fall into the firepot.
It is possible to do this operation only if the stove is in FINAL CLEANING phase or OFF.
Capitolo
Pagina
4
1
Automatic Function
Manual Function
As described before, the user can easily set on the display the percentage of the hot air to deliver in
a room. Here is described the procedure for the modification of the canalization following the needs of
the user.
- At chapter 7.2 of the user and maintenance manual , follow the procedure to enter in the
menu USER , go to the icon (fig.1) with key 2 and get access with key OK to the function Air front/
rear to display the setting (fig.3)
Fig.3
Fig.2
Fig.1
- Once entered in the function, choose the canalization with key 1 and 2 as described in the previous
table.
b) Automatic function (symbol on the display
):With this function, if activated, is possible
to let manage independently to the stove the 5 levels of canalization. The important premise is that, by
activating the automatic function, is necessary to install a room sensor (optional) or an external thermostat in the room to canalize and follow the procedure on the display:
-
Enter in the page for the setting of the room temperature (reference fig. 4 and paragra
ph 7.2.2 of the user and maintenance manual);
-
Confirm twice with key OK till the room setting of the canalization appears (fig.5)
Fig.4
Fig.5
Capitolo
Pagina
4
2
Modify the room setting with key 1 and 2 , the values goes from OFF-EST -07 -40-MAN
OFF: manual function with the setting of the canalization levels done by the user
EST: automatic function with automatic management of the levels of the canalization
following the request of an external thermostat installed in the room to canalize.
VALUE: automatic function with automatic management of the levels of canalization fol
lowing the request of the two set room temperatures (reading of the room sensors).
MAN: automatic function with automatic management of the levels of canalization; the
temperature of the canalization is never reached so that the canalization is always activa
ted;
he wiring of the sensor in the motherboard should be made as in the following scheme:
N.PEL.
N.H2O
N.AMB. TERM.
-TC1+
N.AMB. TERM.
Rosso
Blu
Nero
Nero
Nero
-TC1+
9
10
Nero
SONDA
AMBIENTE
REAR
o
TERMOSTATO
ESTERNO
REAR
SONDA
AMBIENTE
FRONT
TERMOSTATO
SONDA FUMI
ESTERNO
FRONT
Once the room sensor of the canalization is connected to the motherboard, as well as the standard display of the room temperature as in fig. nr. 6, you can read the room sensor of the canalization (fig.7).
the system let modulate the stove once the set temperatures in the rooms are reached.
Fig.6
Fig.7
Attention: F means FRONT and shows the temperature measured by the sensor or the external thermostat placed in the same room where the stove is installed.
R means REAR and shows the temperature measured by the sensor or the external thermostat placed
in the same room where the canalization is installed.
IMPORTANT: During the installation it is necessary to set the difference of the cubic volume of the
rooms if you want to use in the better way the automatic function of the canalization.
The setting of the cubic volume is on three levels as in fig. 9:
= (SAME): IF THE CUBIc VOLUME OF THE TWO ROOMS IS MORE OR LESS SIMILAR
+ REAR: if the cubic volume of the room where is installed the canalization is more than the one where
the stove is installed;
+ FRONT: if the cubic volume of the room where is installed the canalization is less than the one where the stove is installed.
To get access to the function please follow this procedure:
-
At chapter 7.2 of the user and maintenance manual , follow the procedure to enter in the
menu USER , go to the icon (fig.8) with key 2 and get access with key OK to the fun
ction (fig.9)
Fig.8
Fig.9
Modify the cubic volume with key 1 and 2: confirm with key OK.
Capitolo
Pagina
4
3
Capitolo
Pagina
4
4
4.1.1
Single duct
The single duct has 2 air ducts , one for the heating from the front and another for the heating from the back of the stove, which are
completely independent one from the other.
The heat exchanger, divided in three levels of stainless steel tubes, is based on a brand new concept for the managing of the air ,
which does not work anymore blowing toward the duct but with a second fan that works in aspiration, in the way that is possible to
recover a bigger percentage of heat produced by the stove.
See picture above.
In the single Flow stove the firmware does not include the possibility to switch off the front vent ( on back mode the front vent
works on minimum power).
Moreover , to prevent the risk of overheating of the stove ( hot fumi) caused by wrong settings, is not possible to set up the voltage.
Capitolo
Pagina
4
5
Funzione AUTOMATICA
Funzione MANUALE
):
As described before, the user can easily set on the display the percentage of the hot air to deliver in
a room. Here is described the procedure for the modification of the canalization following the needs of
the user.
- At chapter 7.2 of the user and maintenance manual , follow the procedure to enter in the
menu USER , go to the icon (fig.1) with key 2 and get access with key OK to the function Air front/
rear to display the setting (fig.3)
Fig.1
Fig.2
Fig.3
- -Once entered in the function, choose the canalization with key 1 and 2 as described in the
previous table.
B)
):
With this function, if activated, is possible to let manage independently to the stove the 5 levels of
canalization. The important premise is that, by activating the automatic function, is necessary to install
a room sensor (optional) or an external thermostat in the room to canalize and follow the procedure on
the display:
- Enter in the page for the setting of the room temperature (reference fig. 4 and paragra
ph 7.2.2 of the user and maintenance manual);
- Confirm twice with key OK till the room setting of the canalization appears (fig.5)
Fig.4
Fig.5
Capitolo
Pagina
4
6
Modify the room setting with key 1 and 2 , the values goes from OFF-EST -07 -40-MAN
OFF: manual function with the setting of the canalization levels done by the user
EST: automatic function with automatic management of the levels of the canalization
following the request of an external thermostat installed in the room to canalize.
VALUE: automatic function with automatic management of the levels of canalization fol
lowing the request of the two set room temperatures (reading of the room sensors).
MAN: automatic function with automatic management of the levels of canalization; the
temperature of the canalization is never reached so that the canalization is always activa
ted;
N.PEL.
N.H2O
N.AMB. TERM.
-TC1+
N.AMB. TERM.
Nero
Rosso
Blu
Nero
Nero
Nero
o
o
STANZA
REAR LEFT
-TC1+
9
10
Nero
SONDA
SONDA
AMBIENTE
AMBIENTE
REAR LEFT REAR RIGHT
SONDA
o
o
AMBIENTE
TERMOSTATO TERMOSTATO
FRONT
ESTERNO
ESTERNO
REAR LEFT REAR RIGHT
TERMOSTATO
SONDA FUMI
ESTERNO
FRONT
STANZA
REAR RIGHT
Once the room sensor of the canalization is connected to the motherboard, as well as the standard display of the room temperature as in fig. nr. 6, you can read the room sensor of the canalization (fig.7).
the system let modulate the stove once the set temperatures in the rooms are reached.
Fig.6
Fig.7
Fig.8
Attention: F means FRONT and shows the temperature measured by the sensor or the external ther
mostat placed in the same room where the stove is installed.
RR means REAR RIGHT and shows the temperature measured by the sensor or the external thermostat placed in the same room where the right canalization is installed.
RL means REAR LEFT and shows the temperature measured by the sensor or the external thermostat placed in the same room where the LEFT canalization is installed.
IMPORTANT: : During the installation it is necessary to set the difference of the cubic volume of
the rooms if you want to use in the better way the automatic function of the canalization.
The setting of the cubic volume is on three levels as in fig. 10:
= (sAME): IF THE CUBIc VOLUME OF THE TWO ROOMS IS MORE OR LESS SIMILAR;
+ REAR RIGHT: if the cubic volume of the room where is installed the RIGHT canalization is more than
At chapter 7.2 of the user and maintenance manual , follow the procedure to enter in the
menu USER , go to the icon (fig.9) with key 2 and get access with key OK to the fun
ction (fig.10)
Fig.9
Capitolo
Pagina
4
7
Fig.10
- Modify the cubic volume with key 1 and 2: confirm with key OK.
Handling of the front fan: the blower that is blowing the hot air in the front part of the stove is
working independently from the set of the automatic set up of the two rear blowers for the canalization. In case the stove should be set to work in Power 5 with the canalization in position Middle, the
power of the front blower can be set as follow:
0 front blower not activated (if the front blower is deactivated during the automatic set up, the
temperature value set for the front room, is no longer considered as a value that will lead the stove
into modulation.
Value 1 to 5 - power of the front blower that can be adjusted independently from the power of
the stove, provided in not higher than the same (only exception when the stove enter in Modulation;
also the front blower goes ALWAYS at minimum power)
A The front blower ALWAYS follow the power set in the stove.
Remark: With the automatic set of the canalization activated and front blower in working condition, if
the two rooms temperature of the canalization is reached, but the temperature of the main room where the stove is set is not reached, the blower goes in A and when this condition is reached, the blower
power can no longer be modified (can only be deactivated setting the 0
Capitolo
Pagina
4
8
4.2.1
RC - Double duct :
The double duct stove has three air ducts , one for the heating from the front and another two for the heating from the back of the
stove, which are completely independent one from the others.
The heat exchanger, divided in two levels of stainless steel tubes, is based on a brand new concept for the managing of the air ,
which does not work anymore blowing toward the duct, but with two fan working in aspiration, in the way that is possible to recover
a bigger percentage of heat produced by the stove.
See picture above.
In the single Flow stove the firmware does not include the possibility to switch off the front vent ( on back mode the front vent
works on minimum power).
Moreover , to prevent the risk of overheating of the stove ( hot fumi) caused by wrong settings, is not possible to set up the voltage.
Ver 1 of 12/03/2012
Chapter
Page
8
1
ALARMS
In the event that a functional anomaly is verified, the card intervenes, signals the irregularity and operates in different modes according to the type of alarm. The following alarms are foreseen.
Alarm origin
Code
Screen display
02
Smoke over-temperature
03
Failure to light
05
Flame anomaly
11
06
01
BLACK-OUT
08
DEPRESURIZATION ALARM
07
TEMPERATURE ALARM
04
12
Door open
13
Brazier obstruction
13
Unserviceable debimeter
09
15
Defective cabling
14
16 rate-determining
step
PRESSURE ALARM
10
OUT
any
SWITCHING ON
any
BLACK-OUT ALARM
WORK
< TF44
WORK (*)
WORK
> TF44
BLACK-OUT ALARM
FINAL CLEANING
any
ECO-STOP
any
ECO-STOP (*)
Ver 1 of 12/03/2012
Chapter
Page
8
2
NB: Each alarm condition (excluding alarm 09) causes the immediate switching off of the stove, with
the extactor active at maximum power and the exchanger at PT5 speed until reaching the dedicated
TF06 threshold. The alarm status is reached after TF43 time can be zeroed by pressing the OK button.
IMPORTANT! Each alarm is only displayed after a time has elapsed as established in
the TF 43 timer Alarm Delay parameter, with the exception of the PELLET FINISHED, BLACK-OUT
e DEBIMETER UNSERVICEABLE alarms.
IMPORTANT! When an alarm is activated, it is no longer possible to start the stove until that alarm
is reset by holding the OK button pressed.
AIR MODULATION
WATER MODULATION
WORK MODULA
CLEANING BRAZIER
SWITCHING OFF
WORK
With RDS disabled
WORK MODULA
ECO STOP
TF33-37
TF15/TF06/TF46
TF14/TF18/TF27orTF21
CLEANING BRAZIER
CLEANER ACTIVE
TF16/TF17
TF16/TF17
TF16/TF17/TF18 TF16/TF17
TF16/19/22/25/28 TF17/20/23/26/29
TF18/21/24/27/30 TF06
TF09/TF08/TF32
TF48/TF31/TF02/TF05/TF01
TF48/TF32/TF04/TF02/TF01
WORK MODULA
WATER MODULE
MODULA AIR
WORK
THIS FLAME
COLOUR BLUE --> Function phases relating to gamma HYDRO stoves and related involved parameters.
TF39
NONE
CLIMATE COMFORT
DELAY SELECTED ON
MENU
TF07/TF15/TF45
TF12/TF11
TF13
NONE
NONE
NONE
TF09
TF05
DELAY FLAME
LIGHT UP - RESET
TF48/TF49/TF04/TF02/TF01
PARAMETERS
INVOLVED
IN OFF
Page
Legend:
After switching
by OK
ATTEMPT
RESTART
FINAL CLEANING
FAN START DELAY
NONE
TF15/TF45
With Keystroke P3
WORK
TF12
TF 04
THIS FLAME
After PRE-HEATING
TF07/TF15
if T. SMOKE> TF15
& T. SMOKE <TF07
LIGHT
DELAY FLAME
TF15
if T. SMOKE <TF15
STATUS
MESSAGE
DISPLAYED
ON /
PRE-HEATING
TF15/TF46
PARAMETER
INVOLVED IN
CONDITION
CONDITION
Code
STATUS
STATUS
Ver 1 of 12/03/2012
9
1
10
1
Capitolo
Pagina
EXTINCTION
REQUEST
-OK for 4 seconds
- Shut off
CHRONOTHERMOSTAT
ECO STOP
CONDITIONS
OPERATION
SMOKE
TEMP.>TF15
SMOKE
TEMP.<=TF15
T.FUMI<TF 15
after TIMER TF 46
DISPLAY
EFFECT
FINAL CLEANING
OFF
FINAL CLEANING
OFF
OFF
//
After the smoke probe has reached the value set in the TF15, the TIMER TF46 (T-MIN EXTINCTION) is activated in
order to check that the flame has gone out completely.
IMPORTANT!!! the TIMER mentioned above, that can be set manually by the PR40, must have a value equal to
the time needed to extinguish the flame, even after the WAIT FLAME phase where the firepot must consume
a large amount of pellets before the OFF status.
10.2 FINAL CLEAN with Re-ignition attempt
If a Re-ignition is requested after the FINAL CLEAN, the switchboard must behave as follows:
EXTINCTION
REQUEST
CONDITIONS
OPERATION
SMOKE
FINAL CLEANING (until next
TEMP.>TF07
condition)
- OK for 4 seconds
T.SMOKE<=TF07
- Ignition with
& SMOKE
FINAL CLEAN (until TF45
CRONOTHERMOSTAT
TEMP.>TF15
- Ignition with COMFORT
FINAL CLEAN (until TF45
T.SMOKE<TF07
timer)
DISPLAY
EFFECT
FAN WAIT
RE-START
RE-START
FAN WAIT
RE-START
RE-START
FAN WAIT
RE-START
START
Before every START - RE-START phase, the stove carries out a further final clean according to TIMER TF45 (REIGNITION BLOCKAGE) in order to burn all pellets inside the fire pot.
.
IMPORTANT!!! the TIMER mentioned above, that can be set manually by the TF45, must have a value equal to
the time needed to extinguish the flame, even at high temperatures.
Blu
Marrone
DEBIMETRO
AUX3
Termostato esterno
NON FORNITO
BLU
GND
MICROPROC.
+5V
INTEGRATO
ENC
N.PEL.
N.H2O
Nero
Nero
N.AMB. TERM.
Marrone
Rosso
Blu
Blu
Nero
Bianco
Bianco
Blu
Nero
Blu
Blu
Nero
Marrone
Blu
-TC1+
RELE
N
F
SCAMB. FUMI
COC.
ACC.
AL1 AL2
N
V2/PO
AL3
SERIALE
AUX2
Condensatore
CONNETTORE
Marrone
Nero
Marrone
AUX1
Giallo / Verde
Nero
Blu
Blu
Nero
Blu
Blu
Marrone
Bianco
Bianco
Bianco
Giallo / Verde
Blu
Nero
Marrone
Giallo / Verde
Giallo / Verde
Blu
Marrone
Nero
Marrone
Blu
Giallo / Verde
Nero
Blu
Marrone
Bianco
Rosso
Nero
Encoder
Pagina
11.1 Air
11
1
Blu
Marrone
DEBIMETRO
AUX3
Sonda ambiente
NON FORNITA
Termostato esterno
NON FORNITO
BLU
GND
MICROPROC.
+5V
INTEGRATO
ENC
N.H2O
T.amb. Rear o
T.ext. Rear
Marrone
T.amb. Front
Blu
Rosso
Blu
Nero
Bianco
Bianco
Blu
Nero
Blu
Blu
Nero
Marrone
Blu
-TC1+
Nero
Nero
N.AMB. TERM.
Nero
Nero
T.ext. Front
N.PEL.
RELE
N
F
SCAMB. FUMI
COC.
ACC.
AL1 AL2
N
V2/PO
Condensatore
CONNETTORE
Marrone
Nero
Marrone
SERIALE
AL3
Giallo / Verde
AUX2
AUX1
Giallo / Verde
T.fumi
Nero
Blu
Blu
Nero
Blu
Blu
Marrone
Bianco
Bianco
Giallo / Verde
Blu
Nero
Giallo / Verde
Giallo / Verde
Blu
Marrone
Nero
Marrone
Blu
Giallo / Verde
Nero
Blu
Marrone
Bianco
Rosso
Nero
Encoder
Pagina
11
2
Blu
GND
+5V
ENC
CONNETTORE
DEBIMETRO
AUX3
Rear Left
Marrone
Front
T.ext.
Termostato esterno
NON FORNITO
T.amb. Rear
Right o T.ext.
Rear Right
Blu
Rosso
Blu
Nero
Bianco
Bianco
Blu
Front
T.amb.
Marrone
Blu
Blu
Blu
Nero
Nero
-TC1+
RELE
N.AMB. TERM.
T.amb. Rear
Left o T.ext.
N.H2O
Sonda ambiente
NON FORNITA
N.PEL.
Canalizzata DX
BLU
MICROPROC.
Condensatore
INTEGRATO
N
F
SCAMB. FUMI
COC.
ACC.
AL1 AL2
N
V2/PO
Marrone
SERIALE
AL3
Canalizzata SX
Marrone
Nero
Scheda madre
Cod. L023_1
Marrone
Giallo / Verde
AUX2
AUX1
Giallo / Verde
T.fumi
Nero
Blu
Blu
Nero
Blu
Blu
Marrone
Bianco
Bianco
Giallo / Verde
Blu
Nero
Giallo / Verde
Giallo / Verde
Blu
Marrone
Nero
Marrone
Blu
Giallo / Verde
Nero
Blu
Marrone
Bianco
Rosso
Nero
Encoder
Pagina
11
3