DTS Py2 01-2013 Eng
DTS Py2 01-2013 Eng
DTS Py2 01-2013 Eng
RECTILINEARDISPLACEMENTTRANSDUCER
WITHBALLTIP
Principal characteristics
The side connection creates a through-rod structure with
double rod support, guaranteeing greater overall strength
of the transducer.
The return spring automatically returns the rod to zero
position, making the transducer suitable for comparator
applications.
The tip with stainless steel ball is suitable for applications
where the object to be measured is not subject to shifts
transverse to the transducer axle.
Ideal for checking the flatness or thickness of panels
of various materials. Can also be used for valves or
mechanical parts when the rod cannot be attached to the
moving object.
MECHANICALDIMENSIONS
10/25/50/75/100
Resolution
Infinite
Independent linearity
(within C.E.U.)
see table
Displacement speed
10 m/s
Displacement force
4N
Life
Vibrations
Shock
50 g, 11ms.
Tolerance on resistance
20%
Recommended cursor
current
< 0,1 mA
10mA
Maximum applicable
voltage
see table
Electrical isolation
Dielectric strength
Dissipation at 40C
(0W at 120C)
see table
Actual Temperature
Coefficient of the output
voltage
< 1,5ppm/C
Working temperature
-30...+100C
Storage temperature
-50...+120C
Case material
Fixing
3 pole Cable
TECHNICALDATA
Important: all the data reported in the catalogue linearity, lifetime, temperature coefficient are valid for a sensor utilization as a ratiometric device with a max
current across the cursor Ic 0.1 mA.
MECHANICAL/ELECTRICALDATA
Model
10
50
75
100
25
50
76
101
76
101
mm
mm
Resistance (C.E.T.)
0.3
0.2
0.1
0.1
0.1
0.2
0.6
1.2
1.8
2.4
14
25
60
60
60
10
25
C.E.U. +1
mm
C.E.U. + 5
mm
C.E.U. + 38
mm
32
32
40
40
40
mm
108
138
196
251
307
Quote (D)
mm
11
ELECTRICALCONNECTIONS
Connector
output
Cable
output
Blue
Yellow
Brown
Connection
Side
INSTALLATION INSTRUCTIONS
Respect the indicated electrical connections (DO NOT
use the transducer as a variable resistance)
When calibrating the transducer, be careful to set the
stroke so that the output does not drop below 1% or rise
beyond 99% of the supply voltage.
ORDER CODE
Displacement transducer PY2
3 pole PVC cable
output 3x0.25 1m
5 pole connector
output DIN 43322
Model
Cable length
(in metres)
This part of the code only
applies to the model with
cable output
No certificate
attached
Linearity curve to be
attached
Standard mounting
brackets (PKIT005)
Optional mounting
brackets (PKIT006)
0 X
Ex.:PY2 - C - 100
Displacement transducer model PY2, 5-pole connector output, useful electrical stroke (C.E.U.) 100mm.
ACCESSORIES
STANDARDACCESSORIES
Fixing kit: 4 brackets, M4x10 screws, washer
PKIT005
PKIT006
PTAS000
OPTIONALACCESSORIES
5-pin axial female PCB connector DIN43322 IP40 clamp for wire 4 - 6 mm
CON011
5-pin axial female PCB connector DIN43322 IP65 clamp PG7 for wire 4 - 6 mm
CON012
5-pin 90 radial female PCB connector DIN43322 IP40 clamp for wire 4 - 6 mm
CON013
GEFRANspa reserves the right to make any kind of design or functional modification at any moment without prior notice
GEFRAN spa
via Sebina, 74
25050 PROVAGLIO DISEO (BS) - ITALIA
tel. 0309888.1 - fax. 0309839063
Internet: http://www.gefran.com
DTS_PY2_01-2013_ENG