Datasheet Solar Panels
Datasheet Solar Panels
Datasheet Solar Panels
STP300 - 24/Ve
305 Watt
15.7%
0/+5%
3800Pa
5400Pa
Weak light
2%
PID
Resistant
**
Certifications and standards:
IEC 61215, IEC 61730, conformity to CE
Indus
100%
try lea
97%
10
ding li
near w
arran
ty
90%
80,2%
80%
25
10
* Please refer to Suntech Standard Module Installation Manual for details. **PV Cycle only for EU market.
*** Please refer to Suntech Product Near-coast Installation Manual for details. **** Please refer to Suntech Product Warranty for details.
www.suntech-power.com
IEC-STP-Ve-NO1.01-Rev 2014
STP305 - 24/Ve
STP300 - 24/Ve
Electrical Characteristics
992[39.1] 2[0.08]
942[37.1] 1[0.04]
STC
Junction box
Drainage holes
Product label
Barcode
(Back View)
1956[77] 2[0.08]
1176[46.3] 1[0.04]
580[22.8]
1100[43.3]
149[0.550.35]
Mounting slots
4 places
STP305-24/Ve
STP300-24/Ve
305 W
300 W
36.2 V
35.9 V
8.43 A
8.36 A
44.7 V
44.5 V
8.89 A
8.83 A
Module Efficiency
15.7%
-40 C to +85 C
1000 V DC (IEC)
20 A
Power Tolerance
0/+5 %
ww
STC: lrradiance 1000 W/m2, module temperature 25 C, AM=1.5;
Best in Class AAA solar simulator (IEC 60904-9) used, power measurement uncertainty is within +/- 3%
NOCT
4-5.1[0.2]
Grounding holes
40[1.57]
11[0.4]
1.5[0.06]
(Front View)
35[1.4]
15.5%
STP305-24/Ve
STP300-24/Ve
222 W
219 W
32.6 V
32.4 V
6.80 A
6.75 A
40.8 V
40.6 V
7.19 A
7.14 A
NOCT: Irradiance 800 W/m2, ambient temperature 20 C, AM=1.5, wind speed 1 m/s;
Best in Class AAA solar simulator (IEC 60904-9) used, power measurement uncertainty is within +/- 3%
Note: mm[inch]
Temperature Characteristics
9
8
200
-0.33 %/C
0.067 %/C
5
150
Power (W)
Current (A)
452C
250
-0.43 %/C
100
3
2
50
1
0
0
0
10
20
30
40
50
Voltage (V)
1000 W/m2
800 W/m2
600 W/m2
400 W/m2
200 W/m2
Excellent performance under weak light conditions: at an irradiation intensity of 200 W/m2
(AM 1.5, 25 C), 95.5% or higher of the STC efficiency (1000 W/m2 ) is achieved
Dealer information
Mechanical Characteristics
Solar Cell
No. of Cells
72 (6 12)
Dimensions
Weight
Front Glass
Frame
Junction Box
Output Cables
TUV (2Pfg1169:2007)
4.0 mm2 (0.006 inches2), symmetrical lengths (-) 1100mm (43.3
inches) and (+) 1100 mm (43.3 inches)
Connectors
Packing Configuration
Container
20 GP
40 GP
40 HC
25
25
25
12
24
125
300
600
Information on how to install and operate this product is available in the installation instruction. All values indicated in this data sheet are subject to change without prior announcement. The specifications may vary slightly. All specifications are in
accordance with standard EN 50380. Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification.
E-mail: sales@suntech-power.com
www.suntech-power.com
IEC-STP-Ve-NO1.01-Rev 2014