Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Sphere

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 5

DOCUMENT NUMBER

R
E
V
I
S
I

CLIENTE

ITEM

REV.

DATA SHEET SPHERE


PRESSURE

UBICACIN

SERVICE

LPG

UNIT

PAGE. 3 OF 6

DESIGN INTERNAL PRESSURE

300 psig @ 140 F

DESIGN EXTERNAL PRESSURE

FULL VACUUM

MINIMUM DESIGN METAL TEMPERATURE

14 F

DESIGN S.G. OF LIQUID AND LIQUID LEVEL

0,5063@90F

INTERNAL OPERATING PRESSURE

250 psig @ 90 F

EXTERNAL OPERATING PRESSURE

FULL VACUUM

CONSTRUCTION CODE

ASME SEC. VIII, DIV. 1, LAST EDITION AND SPECIFICATION PDVSA D-211

STAMPING

REQUIRED "U" STAMP

MAWP BASIS

BY VENDOR

NATIONAL BOARD REGISTRATION

REQUIRED

SPECIFICATIONS ANS STANDARDS

ASME SEC. VIII DIV. 1 AND SPECIFICATION PDVC-SVG02-DME-85000

CORROSION ALLOWANCE

SHELL & HEADS: 1/8"

RADIOGRAPHING REQUIREMENTS

FULL

WELD PRESSURE JOINT REQUIREMENTS

ACCORDING TO SPECIFICATION PDVC-SVG02-DME-85000 AND PDVSA D-211, PTO. 6.2

IMPACT TESTING

PER CODE & PDVSA D-211

PWHT

PER CODE & PDVSA D-211

HYDROTEST PRESSURE

ACCORDING TO SPECIFICATION PDVC-SVG02-DME-85000 AND PDVSA D 211, PTO. 9

WELD METAL HARDNESS

PER ASME CODE & PDVSA D-211

SERVICE

LETHAL-CRITICAL

PRODUCT

LPG

NOZZLES: 1/8"

COLUMN: 1/16"

MATERIAL
SHELL:

SA-516 Gr. 70

HEADS:

NOZZLE REINFORCING PADS:

SA-516 Gr. 70

STIFFINING RINGS:
PIPE:

NOZZLE / MANWAY NECKS:


FORGINGS:

WELD FITTINGS:

SA-105

CLADDING:

SA-516 Gr. 70

N/A

N/A
PLATE: N/A

SA-106 Gr B / SA-53 Gr. B


SA-105 / SA-234 Gr B

PRESSURE RETAINING BOLTING:

BOLTS:

SA-193 B7

NUTS:

SA-194 2H

INTERNAL BOLTING:

BOLTS:

N/A

NUTS:

N/A

GASKETS:

SPIRAL WOUND WITH SS AND NON-ASBESTO FILLED

INTERNALS

PIPE:

SA-106 Gr B / SA-53 Gr. B

STRU. SHAPES: SA-516 Gr. 70

PLATE:

SA-516 Gr. 70

EXTERNALS

PIPE:

SA-106 Gr B / SA-53 Gr. B

STRUC. SHAPES: SA-516 Gr. 70

PLATE:

SA-516 Gr. 70

VESSEL SUPPORT:
SUPPORTS:

DEMISTER:

SA-516 Gr. 70

LIFTING LUGS: N/A

N/A

LADDERS & PLATFORMS CARBON STEEL

OTHER REQUIREMENTS
LADDER AND PLATFORMS
SHOP PAINT SYSTEM

REQUIRED: STAIRWAYS AROUND OF THE EQUIPMENT AND PLATFORM ON THE TOP


VESSEL: ACCORDING TO PDVSA O-201 (SYSTEM 9)
SUPPORTS: ACCORDING TO PDVSA O-201 (SYSTEM 9)

INSULATION

THICKNESS:

N/A

DENSITY:

N/A

FIREPROOFING

THICKNESS:

2"

DENSITY:

BY SPHERE SUPPLIER OR CONTRACTOR

EXTERNAL LOADING
WIND DESIGN

145 KPH (90MPH) ACCORDING TO UBC 1997

SEISMIC DESIGN

ACCORDING TO SPECIFICATIONS PDVC-SVG02-DME-85000 AND UBC 1997

PRELIMINARY LOADS (TO BE CONFIRMED BY VENDOR)

WEIGHTS ( LBS)

SHIPPING

EMPTY

OPERATING

TEST

207,262

207,262

575,207

1,004,113

WIND LOADING

SHEAR AT BASE =

11233,216 LBS

MOMENT AT BASE =

69730 LBS X FT

EARTHQUAKE LOADING

SHEAR AT BASE =

69730 LBS

MOMENT AT BASE =

1008000 LBS X FT

R
E
V
I
S
I

DOCUMENT NUMBER

REV.

0
CLIENTE
UBICACIN

DATA SHEET SPHERE


PRESSURE

ITEM

UNIT

SERVICE

LPG

01

PAGE. 4 OF 6

CONNECTION SCHEDULE
MARK

QTY

SIZE

FACING / TYPE

RATING

SERVICE

ORIENTATION

PROJECTION (IN)

REMARKS

N1

3"

WN / RF

300#

OUTLET

BOTTOM

NOTE 2

N2

2"

WN / RF

300#

LEVEL SWITCH

270

NOTE 2

N3

3"

WN / RF

300#

LEVEL TRANSMITTER

45

NOTE 2

N4

1 1/2"

WN / RF

300#

PRESSURE TRANSMITER

45

NOTE 2

N5

4"

WN / RF

300#

RELIEF VALVE

285

NOTE 2

N6

4"

WN / RF

300#

RELIEF VALVE

285

NOTE 2

N7

4"

WN / RF

300#

INLET

270

NOTE 2

N8

1 1/2"

WN / RF

300#

THERMOWELL

NOTE 2

N9

1 1/2"

WN / RF

300#

THERMOWELL

180

NOTE 2

N10

2"

WN / RF

300#

LEVEL SWITCH

180

NOTE 2

N11

2"

WN / RF

300#

RECIRCULATION

90

NOTE 2

MH

24"

WN / RF

300#

MANHOLE

TOP

12

NOTE 2 AND 3

0o

PLANT
NORTH

N8

285o

MH
N3

N6

45o

N5

3' 7"

N4

N2
N7
270o

2' 5"

2' 1"

1' 7"

2' 4"

2' 4"

3' 8"

180o

PLANT

90o

N11

R
E
V

DOCUMENT NUMBER

REV.

I
S
I

CLIENTE

UBICACIN

DATA SHEET SPHERE


PRESSURE

ITEM

UNIT

SERVICE

LPG

01

PAGE. 5 OF 6

MH
DISTRIBUTOR WITH SPRAYERS
(NOTE 17)
N5

N3

N2

N8

N11

N4
N6

N7

HLL = 7' 4"


THICKNESS MIN. 1,5"
INT. DIA. 29'

TANGENT LINE 0' - 0"


REFERENCE LINE (NOTE 4)

11'-4''
LLL = - 9' 4"
HEIGHT
23'-6''
(NOTE 14)

9'- 6''

8 - 48" LEGS SUPPORTS

(2) ELECTRICAL
GROUNDING

(NOTE 14)
N9

N10
N1

BASE 48" X 48"; WITH BOLTS OF


2 1/2" DIAMETER
(NOTE 14)

COLUMNS BASE
CIRC. DIA. 28'-6''

ELEVATION

R
E
V

DOCUMENT NUMBER

REV.

I
S
I

CLIENTE

UBICACIN

N
ITEM

DATA SHEET SPHERE


PRESSURE

0
0

UNIT

SERVICE

LPG

01

PAGE. 6 OF 6

NOTES
1) ALL THE NOZZLES HOLES AND ANCHOR BOLTS SHALL BE EQUAL SPACED TO THE EQUIPMENTS MAIN AXES
2) ALL THE NOZZLES PROJECTIONS ARE REFERRED FROM THE OUTSIDE OF THE SPHERE, UP TO THE FLANGE FACE
3) WITH BLIND FLANGE, GASKET, BOLTS AND NUTS (DAVIT SHALL BE DESIGNED ACCORDING TO PDVSA 10603.2.102).
4) HLL AND LLL ELEVATIONS SHALL BE FROM THE REFERENCE LINE
5) NOMINAL CAPACITY: 2300 Bbls. WORKING CAPACITY: 2140 Bbls
6) ALL THE NOZZLES ELEVATIONS AND LEVELS ARE REFERRED TO THE REFERENCE LINE.
7) THE STAIRWAY, PLATFORMS AND CLIPS WELDED TO THE EQUIPMENT SHALL BE MANUFACTURERED
AND INSTALLED BY THE CONTRACTOR
8) STAIRWAY SALL BE MANUFACTURED AT THE CONTRACTORS SHOP.
9) THE EQUIPMENTS EMPTY, SHIPPING, OPERATING AND TESTING WEIGHTS SHALL BE CONFIRMED BY CONTRACTOR.
10) THE WIND AND SEISMIC LOADS SHALL BE CONFIRMED BY CONTRACTOR.
11) CONTRACTOR SHALL APPLY FULL PENETRATION WELDING FOR ALL THE EXTERNAL ACCESSORIES WELDED TO THE SPHERE.
12) THE STRUCTURAL CALCULATIONS FOR THE SPHERE SHALL BE MADE BY THE CONTRACTOR.
13) CONTRACTOR SHALL INSTALL THE DISTRIBUTOR, INCLUDING THE SPRAYS. CIRCULAR SPRAY WITH 26 ORIFICES
APPROXIMATED OF 3/8" (10 mm) INTERNAL DIAMETER.
14) THE LEGS SUPPORTS AND THE BOTTOM PLATES JOINTS SHALL BE DESIGNED BY CONTRACTOR (INCLUDING ANCHORES).
15) CONTRACTOR SHALL PROVIDE THE FIRE PROTECTION SYSTEM ACCORDING TO NFPA15. SHALL BE CONSIDERED PIPE RING
AND SPRAYS AROUND OF THE SPHERE
16) CONTRACTOR SHALL PROVIDE PIPES FOR FIRE PROTECTION SYSTEM UP TO 3' 6" OF DISTANCE FROM THE SPHERE
(INCLUDING SUPPORTS,ACCESORIES, ETC.)
17) MAXIMUM FILLING RATE = 375 GPM
MAXIMUM EMPTYING RATE = 225 GPM

NORMAL FILLING RATE = 250 GPM


NORMAL EMPTYING RATE = 150 GPM

You might also like