Analysing The Results: Versus Log H Is Plotted. by Comparing This Equation of Log
Analysing The Results: Versus Log H Is Plotted. by Comparing This Equation of Log
Analysing The Results: Versus Log H Is Plotted. by Comparing This Equation of Log
The graph
log Qactual
Cd A3
2g
A 2
1( 3 )
A1
graph. This proved that the graph plotted is correct. Next, the gradient from the
equation is 0.5 while the gradient obtained from the graph is 0.5461. The
theoretical gradient value and the gradient value obtained from the graph are
slightly different. While the y-intercept obtained from the graph is -3.3432. From
y-intercept, we are able to calculate the value for
Log n
-3.3432
log C d A 3
= Log
2g
A 2
1( 3 )
A1
C d (7.854 x 105
C d as below:
= -3.3432
2 ( 9.81 )
7.854 x 105
1
3.269 x 104
2 ( 9.81 )
7.854 x 105
1
3.269 x 104
3.3432
Cd=
= 0.9672
Average
Cd =
Cd
and average
Cd
Thus, the overall result that we obtained for venturi meter is incorrect. This is
due to some errors made while conducting the experiment and also errors that
might come from the apparatus been used in experiment. This will further
discuss in question (v).
The graph of Qact against h for method D and 1/D and method upstream and
downstream is plotted.
Theoritically,
aA
Q act C
d
A2 - a2
2g h
...........where
aA
meter coefficien t
A2 - a 2
aA
C
2g
d
A2 - a 2
Qact =MX+c, m =
.
For the D and 1/2D tappings method, the m=1.3539, therefore;
aA
A2 - a 2
C
d
2g
=1.3539
Cd
= 1.3539
= 1.3539
A a
aA
)
2
0.00038 0.0001
0.000380.0001 29.81
=1.081
For method D and 1/2D, the average coefficient discharged Cd is,
Average
Cd =
1.7449+1.7228+1.7813+
3
= 1.750
Cd
1.3777+ 1.5856+1.7472
3
= 1.570
higher, this shows that the data collected during the experiment was not
significantly accurate. The data collected using the orifcee plate meter was
having a greater variation than the accurate value, this shows that there
were some errors while conducting the experiment.
Conclusion
The objective of this experiment was to determine and compared the coefficient of
discharged, Cd for a series of flow measuring devices.
From the experiment, we can conclude that the logarithm value for Qactual is directly
proportional with the increasing logarithm value for
slopes of graphs are seen to be deviate from the theoretical value Cd. From the graph that we
constructed, we can measure the coefficient discharged, C d by measuring the slope of the Q actual
versus
h . The height of the manometer reading will effects the coefficient discharged, C d.
And also, Qtheoritical is inversely proportional to coefficient discharge, C d. so the higher the Qtheoritical,
the lower the Cd.
However, this experiment involved with some errors that will affect the accuracy of the
result, hence, we should take the measurements repeatedly and carefully throughout the
experiment to minimize the error in the experiment.
Appendices
1
2g h
2
1- m
Qth = a
2
= (3.14159 x 10-4)
2 x 9.81 x 0.397
10.0256
Logarithm h = Log h
= Log 0.397
= -0.4012