OXYFLEX - MT Membrane Disc Diffusers consist of a flat, heavily ribbed and fibreglass-reinforced polypropylene base plate and a mounted
membrane (e.g. EPDM).
The OXYFLEX - MT Membrane Disc Diffuser is manufactured in two sizes: OXYFLEX - MT 235 (free membrane diameter of 235 mm) and
OXYFLEX - MT 300 (free membrane diameter of 300 mm).
The base construction is a fibreglass-reinforced polypropylene disc. The membrane is form-fitted to this disc with a plastic ring made of fibreglassreinforced polypropylene.
The OXYFLEX - MT - MT is supplied with a robust 1 thread connector as standard. It is also available with a connector on request.
The OXYFLEX - MT - MTAS design includes a clamp saddle for the assembly on round pipes.
MEMBRANE VARIANTS
Our disc diffusers are equipped with a robust EPDM membrane as standard. For special requirements, the MT300 is also available with silicon
membranes.
The membrane has a special slot arrangement. The size and arrangement of the slots are such that the perfect oxygen transfer or minimum
pressure loss is achieved for high specific loads depending on the application.
All OXYFLEX - MT disc diffusers are available with both a fine bubble and coarse bubble membrane perforation.
PRODUCT CHARACTERISTICS
OXYFLEX - MT Membrane Disc Diffuser
[ have a low pressure loss,
[ are resistant against contamination,
[ in the fine-bubble design, they produce gas bubbles with a diameter < 1-3 mm.
Since, in contrast to the tube diffusers, the entire diffuser surface is on the same hydraulic level, the gas through put is even across the entire
membrane surface and control range.As a result, both the service life and performance are optimised.
OPERATING RANGE AND PERFORMANCE
OXYFLEX - MT Membrane Disc Diffusers are suited for the installation on plastic or steel pipes and for all tank shapes, but they are particularly
suited for small tank volumes, grit chambers and first high loaded stages.
OXYFLEX - MT Membrane Disc Diffusers have successfully proven their capabilities in communal and industrial plants in all parts of the world.
The membrane diffuser element can easily be changed if required.
OXYFLEX - MT Membrane Disc Diffusers can be operated intermittently.
OXYFLEX - MT Membrane Disc Diffusers have a very broad control range between 0 and 15 /h.
For normal specific loads please refer to the data sheets of the relevant variant.
OXYFLEX - MT Membrane Disc Diffusers achieve very high oxygen transfer rates in pure water of more than 25 g O2/ x mET for a flat layout and
suitable water depths.
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
Gesellschaft fr Umweltund Verfahrenstechnik mbH
Polypropylene (PP-GF)
EPDM / silicon
EPDM
30
25
1
()
300
The recommended minimum distance
between the bores in the pipe is 360 mm.
345
30
Polypropylene (PP-GF)
EPDM
EPDM
25
1
()
235
280
The recommended minimum distance
between the bores in the pipe is 295 mm.
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
Gesellschaft fr Umweltund Verfahrenstechnik mbH
30
25
20
10
0
0
10
12
14
16
18
16
18
/h]
Pressure loss*
Comparsion between the fine bubble and coarse bubble
OXYFLEX - MT300 Dp
50
45
40
Pressure loss
Dp [hPa]
35
30
25
20
10
12
14
/h]
* The oxygen transfer values were determined for common installation situations and vary depending on the plant. The characteristics, which
are shown here, do not entitle the user to warranty claims. We will be pleased to prepare plant-specific characteristic curves for you on
request. Pressure losses were determined without the installation of an additional return flow prevention unit.
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
Gesellschaft fr Umweltund Verfahrenstechnik mbH
30
25
15
10
0
0
10
12
16
14
18
/h]
Pressure loss*
Comparsion between the fine bubble and coarse bubble
OXYFLEX - MT235 Dp
50
45
Pressure loss
Dp [hPa]
35
30
25
20
10
12
14
/h]
* The oxygen transfer values were determined for common installation situations and vary depending on the plant. The characteristics, which
are shown here, do not entitle the user to warranty claims. We will be pleased to prepare plant-specific characteristic curves for you on
request.
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
INSTALLATION INSTRUCTIONS
PREPARATION
Before the installation of the OXYFLEX - MT Membrane Disc Diffusers you must check that the pipes are clean. All drilling chippings, dirt, etc.
must be removed when the fans are switched on, otherwise they get carried into the diffusers. Here they can cause significant impairment or even
damage to the diffusers.
LEVELLING
OXYFLEX - MT Membrane Disc Diffusers are assembled to round and square pipes. The pipe system must be levelled to a maximum of 10 mm.
INSTALLATION
The OXYFLEX - MT Membrane Disc Diffuser is to be assembled on a distribution pipe. The assembly can be carried out using an integrated
thread socket or a clamp saddle.
The clamp has a hinge so that it can be swung open. The clamp is inserted into the existing 20-mm diameter bore with the supply air
connector (16 mm diameter) from above.
Now the clamp is closed and screwed using an M8 x 65 mm hexagonal screw (10 Nm) and a self-locking nut.
Possible dimensions of the round distribution pipe:
Special steel design: DN 50 / 60.3 mm, DN 65 / 76.1 mm, DN 80 / 88.9 mm
Plastic design: OD 63 mm, OD 75 mm / OD 90 mm / OD 110 mm
(Further sizes are available on request.)
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
Gesellschaft fr Umweltund Verfahrenstechnik mbH
After the OXYFLEX - MT Membrane Disc Diffusers have been installed, their functioning and leak-tightness must be checked. For this purpose,
the tank is filled with clean water to a maximum 10 cm above the diffuser top edge and the recommended air volume is applied to the diffusers
according to tables I + II. Make sure that you start with the maximum specific load and move across the control range down to the minimum
specific load. Then check and document the leak-tightness and function of the diffusers.
DIFFUSER RUN-IN
After the functional check and leakage check have been completed, we recommend that the OXYFLEX - MT Membrane Disc Diffusers are
operated continuously with the recommended specific load according to tables I + II for at least another 60 minutes.
You need to increase the water level to at least 100 cm above the diffuser top edge as quickly as possible.
IMPORTANT:
The diffusers must not be shut down during this process. The maximum specific load of the respective model variants according to tables I + II
(product data sheet) must not be exceeded during this process.
CHECKING THE BUBBLE IMAGE
The bubble image should be assessed at the earliest after the run-in of the diffusers has been completed. For this purpose, operate the diffusers
from the maximum specific load down to the minimum specific load and check the following items, in particular:
Evenness of the aeration (bubble image test) for a tank filling up to at least 60-100 cm of water above the diffuser top edge and a specific load
according to tables I + II. The evenness of the aeration for minimum specific loads can only be achieved at a water temperature of above 10 C.
OXYGEN TRANSFER TEST
Prior to carrying out an oxygen transfer test as proof of efficiency of the OXYFLEX - MT Membrane Disc Diffuser, the above steps must have
been completed. The oxygen transfer test can be carried out according to acknowledged regulations (e.g. ATV guideline) subject to the clean
water method or waste water method. The warranty values must be specifically operated and tested. A calibrated and exact measurement of the
air volume is required.
COMMISSIONING
The diffuser can be commissioned after a successful oxygen transfer test has been completed. If commissioning is delayed, make sure that the
diffusers are sufficiently covered by water (at least 100 cm) so that the OXYFLEX - MT Membrane Disc Diffusers are protected against strong
sunlight and/or frost.
MT300
fine bubble
MT300-CB
coarse bubble
0 - 10
0 - 16
Run-in
Bubble Image
12
MT235
fine bubble
MT235-CB
coarse bubble
0-6
0 - 12
Run-in
Bubble image
Table I
Operation range
Table II
Operation range
von-Drais-Strae 7 D-55469 Simmern Tel.: +49 6761 / 9 65 09-00 Fax: +49 6761 / 9 65 09-01 info@oxyflex.de
(January 2014)
Supratec
Gesellschaft fr Umweltund Verfahrenstechnik mbH
MAINTENANCE INSTRUCTIONS
MAINTENANCE
The OXYFLEX - MT Membrane Disc Diffusers are low-maintenance units and are partly self-cleaning due to different specific air loads during the
normal operating cycle.
However, we recommend that you only operate the diffusers during regular full-load operation for a maximum of 15 minutes (see tables I + II).
In order to do this it might be sufficient to slide-clean individual strings.
This is also used for removing deposits after longer periods of inactivity and long-term operation with low specific loads.
MONITORING
Before every emptying of the tanks, the diffusers must be visually inspected to check that they are in good condition. During this inspection you
should pay special attention to possible deposits. If deposits are present, these must be carefully removed. The bubble image must be checked and
documented daily and the pressure loss monthly. Any obvious changes of the bubble image and/or pressure loss must be reported immediately to
SUPRATEC Gesellschaft fr Umwelt- und Verfahrenstechnik mbH.
For plants with an intermittent operating mode, in particular, damaged OXYFLEX - MT Membrane Disc Diffusers bear the risk that live sludge
ingresses into the entire pipework system. As a result, the functioning and service life of all OXYFLEX - MT Membrane Disc Diffusers will be
impaired.
CLEANING
In general, dirt and contamination (deposits, sludge, plaque, etc.) on the membranes can easily be removed. Depending on the type and
composition of the dirt, one of the following methods or a combination of several methods may be required: These solvents must always be tested
for compatibility and successful results for the individual membranes.
Manually: Cleaning with water and a soft brush
Alkaline solutions: In general, alkaline cleaning agents can be used in a diluted form. The compatibility must always be checked first,
otherwise contact Supratec GmbH.
Acids: In some cases, it might be necessary to add weak acids to the compressed air (see below) or to clean the membranes with diluted acids.
Please contact SUPRATEC for further information.
Oil-containing solvents and other solvents: None of the membrane types are resistant against a wide range of oil-containing solvents
and other solvents.
If you are unsure how to proceed, please do not hesitate to contact us. We are always here to help you.
ACID DOSING
The compressed air can be dosed with diluted acid if required. This acid dosing may extend the cleaning intervals and reduce the pressure loss of
the membranes, which is particularly useful for waste water types that precipitate lime.
Please contact SUPRATEC for detailed information about acid dosing and ask for our dosing station product.
STORAGE
Always store the diffusers in their packaging in a dry and ventilated room. DIN 7716 provisions must be observed.
GENERAL
Supratec Gesellschaft fr Umwelt- und Verfahrenstechnik mbH manufactures state-of-the-art and highly efficient aeration systems, which are
predominantly used for supplying biological waste water treatment processes with oxygen. However, the products can equally be used for the
aeration of liquids of all kinds.
Membrane diffusers (plate, tube and disc diffusers) with a plastic body are marketed under the OXYFLEX brand.
The special characteristics of the OXYFLEX - MT Membrane Disc Diffusers are due to their shape and choice of materials.
We will also carry out the installation of our products for you if required.