Busway Systems

Sentron Busway Overview


Sentron Busway for Global
Power Distribution Applications

Plating
All bus bars are electroplated with tin.
This unique tin plating provides excellent
conductivity and resists outside
elements from attaching to the bars.
Optional silver plating is also available.
Insulation
Sentron Busway is insulated with an
Epoxy Powder Coating system designed
by Siemens Engineers, Epoxy System
Engineers and Epoxy Powder
Specialists, specifically for Siemens
Busway products.
The Siemens exclusive Electrostatic
Spray insulation process produces
uniform application of Epoxy powder
over the entire conductor bar. This is
further enhanced by the inline filter
process and magnetic separator that
helps to eliminate contaminants
common to fluidized bed systems. The
electrostatic application also provides a
better coating consistency than that of
the older fluidized bed process. The
combination of electrostatic spray and
lower oven temperatures produces a
consistent coverage with fewer
impurities and pinholes in the insulation.
The lower oven temperatures reduce the
risk of bar annealing, which affects the
overall quality of the system.
Sentron Busway insulation is Class B,
130C Rated. Every bus bar and
completed assembly is dielectricly
tested to ensure the insulation is free
of defects.

Siemens Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

14-21

BUSWAY
SYSTEMS

Housing
Sentron Busway incorporates an all
aluminum housing. This lightweight
totally enclosed, non-ventilated housing
resists rust and other elements,
distributes heat away from the
conductors, and provides an excellent
ground path. The totally enclosed design
also eliminates the need for derating of
the system regardless of installation
orientation. The housing is covered with
an electrostatically applied light gray
ANSI 61 polyester urethane powder
paint that is scratch resistant and has a
1,000-hour salt spray resistance rating.
Conductors
Sentron Busway conductors have a
compact construction and can be
configured as 3-phase 3-wire, 3-phase
4-wire or 3-phase 4-wire with 200%
neutral. The conductors may be ordered
in copper (98% conductivity), 1000A/in2
M-Rated Copper, Aluminum (58%
conductivity) and 750A/in2 L-Rated
Aluminum. The optional 200% neutral
helps to handle harmonic conditions that
may exist. This system is especially
useful with discharge lighting
(fluorescent) and computer installations.
This will help to minimize overheating
and prolong the life cycle of your power
distribution equipment.
Ground
Sentron Busway offers ground options
to meet your specifications: standard
integral aluminum housing ground and
optional internal grounding bars. An
optional isolated ground is also available
which is especially useful in applications
where a clean ground is needed.

14

Building on a solid foundation of


advanced products for the construction
industry, the Siemens Sentron name is
recognized worldwide as synonymous
with quality and consistent performance.
Sentron Busway delivers impressive
features and benefits that make it ideal
for many types of industrial and
construction implementations.
Engineered to ensure the safe and
efficient distribution of power in
industrial, commercial and institutional
environments world-wide, Sentron
ampacities range from 225A to 5000A
UL and IEC. Thanks to an innovative
design, you benefit from labor-saving
installation and a flexible, compact bus
system that is an ideal fit for most
applications. In fact, Sentron Busway is
one of the industry's least laborintensive systems.
Sentron Busway installs with minimal
hardware and often costs less than
cable and conduit installations. The
lightweight aluminum housing acts as an
integral ground, joint stacks connect
with splice plates featuring a single-bolt
design, and bus plugs and cable tap
boxes offer the industry's largest wire
bending space. An optional 200%
neutral within the bus bar housing
accommodates harmonics common in
today's power systems.
Sentron Busway conductors are
insulated with a state-of-the-art epoxy
insulation system, which is applied using
an electrostatic spray process for
optimal insulation integrity.
Exemplifying the spirit of continuing
innovation, Sentron Busway is now
available with economical and
convenient elbow stacks for changing
left, right, up or down directions at 90
degrees.
And, of course, Sentron Busway is
certified to design standards worldwide,
including UL, NEMA, IEC, CSA, VDE
and BS.
Siemens Busway Business uses
industry leading technology in all its
manufacturing processes. From bus bar
fabrication to Electrostatic Spray Epoxy
insulation, all the processes used in the
manufacturing of Siemens Sentron
Busway are electronically controlled to
provide for consistent, high quality
results, making Sentron Busway
products best in its class.

Overview

Busway Systems

BUSWAY
SYSTEMS

14

Sentron Busway Overview


Joint Stack
Each Sentron Busway piece is shipped
with a joint stack and joint covers
installed at one end of the busway and a
shipping end protector at the other end.
The joint stacks feature a single bolt
design and a special, torque indicating,
double headed break-off bolt. This
eliminates the need for torque wrenches
and assures proper torque at installation
of 55 ft.-lbs.(68 N-m). When the proper
torque value is achieved, the top bolt
head will shear off. Each joint stack
allows for +/- .625 inches (15.8mm)
adjustability at each joint. Over
adjustment is prevented by the joint
covers, which will only allow a .625 inch
(15.8mm) adjustment when the
knockouts on the joint cover are
removed. It is possible to remove any
joint connection assembly to allow
electrical isolation or removal of a
busway length without disturbing
adjacent busway lengths. Isolation joint
stacks are available and used to
electrically isolate a busway section(s)
within a busway run. For easy visual
identification, isolation joint stack
assemblies are painted white.

Overview
Plug-in Opening
Sentron Busway offer plug-in style
busway which feature plug-in openings
rated for finger safety to IP2X in
accordance with IEC 529 and BS EN
60439-1, -2 and BS EN 60529.
Each plug-in opening has a reversible
hinged dead front designed to protect
the contact surfaces from dirt, dust or
moisture. Gasketing is used where
applications require a splash proof
(IP55) rating.
IP Ratings
Sentron Busway is available in a variety
of IP ratings. Use the chart below to
determine the IP rating that best fits
your application needs.
Testing
Each piece of Sentron Busway is factory
tested before shipping. Tests performed
include dielectric tests, which are used
to insure integrity of insulation. In
addition, Sentron Busway is tested in
accordance with both UL and IEC
standards. All Sentron Busway is
manufactured and inspected in an ISO
9001:2000 registered facility.

Standards
All Sentron Busway products meet the
following standards:
UL 857
NEMA BU1
CSA C22.2
IEC 439-1(1993), IEC 439-2 (1993),
IEC 529 (1989)
BS EN 60529
BS EN 60439-1, 60439-2
UL 1479
DIN 4102 Parts 9&12
BS 6387 Parts 11.1 and 11.2
Labor Savings
Using Sentron Busway instead of cable
and conduit can create savings of up to
20 - 30% on total installed costs. Sentron
busway is lightweight, compact and
takes half the time to install as cable and
conduit. Siemens Sentron Busway Cable/Conduit Conversion Software
Program will show you side by side
comparisons of busway vs. cable/conduit.
These comparisons include material
costs, labor costs, bill of materials, and
technical information between busway
and cable/conduit. Contact your local
Siemens sales office to find out more
information, or visit our web site at
www.sea.siemens.com.

Joint Assembly

Plug-In Opening and Cover

Levels of Protection Description


Sentron Busway
Code

Description

Feeder

Plug-In

Sentron Bus Plugs

IP 2X

Plug-In outlet protects against access to live parts by .472 in. (12 mm) test probe, even with cover
opened. Finger Safe

IP 40

Enclosure protects against entry of .039 in. (1.0 mm) test probe. Indoor (Typical UL Designation)

IP 55

Enclosure protects against entry of dust and water jets. Splash Proof

IP 66

Enclosure is dust tight and protects against powerful water jets. Outdoor (International Only)

NEMA 3R

Enclosure protects against rain, sleet and damage from ice formation. Outdoor - NAFTA