Cooker Hood: Operating and Installation Instructions
Cooker Hood: Operating and Installation Instructions
Cooker Hood: Operating and Installation Instructions
Cooker Hood
Operating and Installation
Instructions
Installation Instructions
Technical Information
Your Appliance
Electrical Connections
Electrical Requirements
Electrical Connection
Operating Instructions
Cooker Hood Controls
To Operate
Recirculation
Extraction
Installation Requirements
Unpacking
Clearance Height
Selecting the Type of Installation
Fixing the Chimney to the Canopy
Fitting the Hood to the Wall
Drilling the Shelves
Bottom Shelf
Top Shelf
Installation in Recirculation Mode
Installation with Air Outlet Turned to the Wall
Installation with Air Outlet Turned Left or Right
Final Fixing and Adjustment of Hood
Ducting
Recirculation
Guarantee Conditions
Installation
Child Safety
During Use
YOUR APPLIANCE
OPERATING INSTRUCTIONS
This cooker hood is designed to extract unpleasant
odours from the kitchen, it will not extract steam.
To obtain the best performance it is advisable to switch
on the hood a few minutes before you start cooking and
leave it running for approximately 15 minutes after
finishing.
OPERATING INSTRUCTIONS
This cooker hood can be used to recirculate or extract
contaminated air.
Recirculation
The cooker hood is supplied specified for use in the
recirculation mode with the charcoal filter fitted.
The contaminated air is cleaned by passing through the
filters and than back into the kitchen.
S07_29
Extraction
The contamined air enters the cooker hood passing
through the grease filter and out through the ducting into
the atmosphere.
When used in the extraction mode the charcoal filter is
not required and must be removed.
S07_03
S07_30
External Cleaning
S07_06
Charcoal Filter
The charcoal filter cannot be cleaned, it should be
replaced approximately every three months or more often
if the hood is used for more than three hours per day.
S07_27
S07_31
Worktop Lighting
The lamps should be replaced with a 220-240V 20W
halogen spot lamp.
S07_28
When fitting the new lamp ensure the two pins are
correctly inserted into the slots in the lamp holder.
Charcoal filters, grease filters and lamps can be
obtained from your local Service Force Centre.
Solution
Symptom
The cooker hood will not start
08705 929929
Your telephone call will be routed to the Service Force
Centre covering your postcode area.
GUARANTEE CONDITIONS
Standard Guarantee Conditions
We, AEG, undertake that if within 12 months of the date of the purchase this AEG built-in appliance or any part
thereof is proved to be defective by reason only of faulty workmanship or materials, the company will, at our option,
repair or replace the same FREE OF ANY CHARGE for labour, materials and carriage on condition that:
The appliance has been correctly installed and used only on the electrical supply stated on the rating plate.
The appliance has been used for normal domestic purposes only, and in accordance with the manufacturers
operating and maintenance instructions.
The appliance has not been serviced, maintained, repaired, taken apart or tampered with by any person not
authorised by us.
All service work under this guarantee must be undertaken by an AEG Service Force Centre.
Any appliances or defective parts replaced shall become the property of this company.
Home visits are made between 8.30am and 5.30pm Monday to Friday. Visits may be available outside these hours
in which case a premium will be charged.
EXCLUSIONS
This Guarantee does not cover:
Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or
removable parts of glass or plastic.
Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United
Kingdom.
Appliances found to be in use within a commercial environment, plus those which are the subject of rental
agreements.
Products of AEG manufacture which were not marketed by AEG. This guarantee is in addition to your statutory
and legal rights.
EUROPEAN GUARANTEE
If you move to another country within Europe then your guarantee moves with you to your new home subject to the
following qualifications:
The guarantee starts from the date you first purchased your product.
The guarantee is for the same period and to the same extent for labour and parts as exists in the new country
of use for this brand or range of products.
The product is installed and used in accordance with our instructions and is only used domestically, i.e. a
normal household.
The product is installed taking into account regulations in your new country.
Before you move please contact your nearest Customer Care centre, listed below, to give them details of
your new home. They will ensure that the local Service organisation is aware of your move and able to look
after you and your appliance.
France
Germany
Italy
Sweden
UK
Senlis
Nurnberg
Pordenone
Stockholm
Slough
+33 (0)3 44 62 29 99
+49 (0)911 323 2600
+39 (0)01678 47053
+46 (0)8 738 79 50
+44 (0)1753 219899
INSTALLATION INSTRUCTIONS
It is dangerous to alter the specifications or attempt to modify this product in any way.
Technical Information
DIMENSIONS
HEIGHT (CANOPY):
HEIGHT (CHIMNEY):
WIDTH (CANOPY):
WIDTH (CHIMNEY):
GROSS:
NET:
ELECTRICAL SUPPLY:
POWER CONSUMPTION:
FAN MOTOR:
LAMP:
73 mm
450-850 mm
898 mm
200-270 mm
24.00 kg
19,40 kg
220-240 V (50 Hz)
215 W
175 W
40 W
ELECTRIC HOB:
GAS HOB:
SLOT-IN GAS COOKER
SLOT-IN ELECTRIC COOKER
7 KW
10 KW
13.5 KW
12.4 KW
Note: CE Marking certifies that this appliance complies with the requirements
laid down in EEC directive 89:336. (Electromagnetic compatibility) and
subsequent modifications and Low Voltage directive 72/23/E.
ELECTRICAL CONNECTIONS
This appliance must be earthed
Electrical Requirements
This appliance is fitted with a 3 core mains
cable and must be permanently connected to
the electricity supply via a double-pole switch
having 3mm minimum contact gap on each
pole. A Switched Fuse Connection Unit to
BS1363 Part 4, fitted with a 3 Amp fuse, is a
recommended mains supply connection
accessory to ensure compliance with the Safety
Requirements applicable to fixed wiring
instructions.
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
hood.
10
Installation Requirements
Before installation check the wall to
which the cooker hood is to be fitted for
electric cables, water pipes or gas.
The cooker hood is designed to be fixed to any rigid
vertical surface over a cooking area, and can be used in
the extraction (ducted to the outside) or recirculation
(internal recycling) mode.
The Installation work must be undertaken by a qualified
and competent person. The manufacturer disclaims any
responsibility to damages due to incorrect installation of
the cooker hood or if the cooker hood is not installed in
compliance with relevant regulations controlling this type
of installation.
Unpacking
Before unpacking the cooker hood position the carton
with the arrows pointing upwards as illustrated on the
carton.
S
F
11
Hob
S07_03
2a
2.
3.
4b
W
S07_30
1.
12
4a
INSTALLING INSTRUCTIONS
Fixing the Chimney to the Canopy
1.
2.
3.
4.
5.
G1
C
E
E
A08_TL
S07_08
1.
2.
13
INSTALLING INSTRUCTIONS
3.
Top Shelf
The top shelf only requires drilling if the hood is to be
installed with the air outlet turned upwards.
1.
2.
4.
2
X
1
20
1
48
650
3.
2.
50
20
1.
S07_05
14
100 100
INSTALLING INSTRUCTIONS
Fix the round eyelet screws provided tightly into
the holes (1).
6.
7.
8.
S07_11
5.
4.
20
1
1
20
1
100 100
S07_05
S07_23
3.
48
650
2.
50
1.
15
6.
7.
8.
9.
S07_16
5.
S07_14
INSTALLING INSTRUCTIONS
48
3.
S07_20
35
2.
16
INSTALLING INSTRUCTIONS
(A)
(B)
6.
7.
8.
9.
10.
11.
S
S07_18
5.
S07_22
S07_19
4.
17
INSTALLING INSTRUCTIONS
Final fixing and adjustment of the
hood:
Two adjustable connectors are provided at the rear of
the hood.
(b)
(c)
(d)
(e)
V1
F
S07_21
(a)
2.
3.
S07_22
Ducting
Recirculation
The hood is supplied in the recirculation mode,
with the charcoal filter and the recirculation grille
(G) fitted (over the outlet in the top of the fan
assembly) ready for use.
2.
S07_19
1.
18
V2
INSTALLING INSTRUCTIONS
Electrical connection and working
test:
1.
2.
3.
4.
5.
S07_24
S07_34
19
4329477 01 - 001013