MATERIAL SAFETY DATA SHEET (MSDS)

PRODUCT
IDENTIFICATION

PHYSICAL DATA

FIRE AND
EXPLOSION
HAZARD DATA

D.O.T. SHIPPING NAME


SYNONYM (S)
D.O.T. I.D. NUMBER
D.O.T. HAZZARD CLASS
D.O.T. LABEL (S)
C.A.S. NUMBER
CHEMICAL FORMULA
MOLECULAR WEIGHT
FREEZING POINT
BOILING POINT
VAPOR PRESSURE
SPECIFIC VOLUME
RELATIVE DENSITY, (air=1)
SOLUBILITY IN WATER
DESCRIPTION

FLAMMABLE LIMITS IN AIR


AUTO-IGNITION
TEMPERATURE

FIRE FIGHTING
PROCEDURES

ISOBUTYLENE
Isobutylene
Liquefied Petroleum Gas, Isobutene, 2 Methylpropene
UN-1055
2.1 Flammable Gas
Flammable Gas
115-11-7
C4H8 or (CH3)2C:CH2

56.108
-140.4C, -220.6F
-6.9C, 19.6F
168 kPa (gauge), 24.3 psig @21.1C
0.418m3/kg, 6.7 ft3/lb @ 1 atm, 21.1C
1.947 @ 1 atm, 25C
Negligible
At room temperature and atmospheric pressure
isobutene is a colorless, flammable gas, with an
unpleasant odor. It is shipped as a liquefied gas
under its own vapor pressure.

1.8 9.6 % by volume


465C, 869F
The only safe way to extinguish an isobutylene
fire is to stop the flow of gas. If the flow cannot be stopped, let
the fire burn out while cooling the cylinder and the
surroundings using a water spray. Personnel may have to
wear approach type protective suits and positive pressure selfcontained breathing apparatus. Firefighters turnout gear may
be inadequate. Small secondary fires may be brought under
control by using carbon dioxide or a dry chemical fire
extinguisher and stopping the flow.

Date prepared: September 7, 2007

18005 E. Hwy 225 La Porte, TX 77571 www.gasinnovations.com Ph: 281-471-2200 Fax: 281-471-2201

MSDS-ISOBUTYLENE
PAGE 2 OF 3

HEALTH
HAZARD DATA

UNUSUAL HAZARDS

1. Cylinders exposed to fire may rupture with violent force.


Extinguish surrounding fire and keep cylinders cool by applying
water from a maximum possible distance with a water spray.
2. Flammable gases may spread from a spill after the fire is
extinguished and be subject to re-ignition.

PERMISSIBLE EXPOSURE

OSHA TWA None established.


ASGIH TWA None established.
Isobutylene is a simple asphyxiant.
Inhalation of high concentrations may cause rapid respiration,
dizziness, fatigue, and nausea. Massive exposure may cause
unconsciousness and death. Contact with the liquid phase or
with the cold has escaping from a cylinder may cause frostbite.
None known.

LIMITS
ACCUTE EFFECTS
OVEREXPOSURE

CHRONIC EFFECTS
OF OVEREXPOSURE

FIRST AID
INFORMATION

INHALATION
CONTACT

REACTIVITY
DATE

SPILL OR
LEAKAGE
PROCEDURE

STABILITY
INCOMPATIBILITY

Move victim to fresh air. If not breathing, give artificial


respiration, preferably mouth-to-mouth. If breathing is difficult,
give oxygen. Call a physician.
Treat for frostbite.

HAZARDOUS

( X ) Stable. ( ) Unstable.
Oxidizing materials and compounds that can add
double bonds.
Carbon monoxide, carbon dioxide.

DECOMPOSITION/
OXIDATION PRODUCTS
POLYMERIZATION

( X ) Will not occur ( ) May occur

across

Shut off all ignition sources and ventilate the area. For controlling large flow, personnel may have
to wear approach-type protective suits and positive pressure self-contained breathing apparatus.

Date prepared: September 7, 2007

18005 E. Hwy 225 La Porte, TX 77571 www.gasinnovations.com Ph: 281-471-2200 Fax: 281-471-2201

MSDS ISOBUTYLENE
PAGE 3 OF 3

PRECAUTIONS

STORAGE
RECOMMENDATIONS
PERSONAL PROTECTIVE
EQUIPMENT

BEFORE USING THE GAS

Cylinders should be stored and used in dry, cool, wellventilated areas away from sources of heat or ignition. Do not
store with oxidizers
1. Eye protection Safety glasses should be worn.
2. Respiratory protection Approved respiratory equipment
must be worn when airborne concentrations exceed safe
levels.
2. Skin protection No specific equipment is required.
Gloves are recommended for cylinder handling.
1. Secure the cylinder to prevent it from failing or being
Knocked over.
2. Leak check the lines and equipment.
3. Have an emergency plan covering steps to be taken in the
event of an accidental release.

DISCLAIMER
The information, recommendations, and suggestions herein were compiled form reference material and other sources believed to be
reliable. However, the MSDSs accuracy or completeness is not guaranteed by Gas Innovations or its affiliates, nor is any responsibility
assumed or implied for any loss or damage resulting from inaccuracies or omissions. Since conditions of use are beyond our control,
no warranties of merchantability or fitness for a particular purpose are expressed or implied. This MSDS is not intended as a license to
operate under, or recommendation to infringe on, any patents. Appropriate warnings and safe handling procedures should be provided
to handlers and users.

Date prepared: September 7, 2007

18005 E. Hwy 225 La Porte, TX 77571 www.gasinnovations.com Ph: 281-471-2200 Fax: 281-471-2201