Composites 2006 PDF
Composites 2006 PDF
Composites 2006 PDF
L5221:P91
Cl/Sfb
(4-)
EPIC
E111:X82
Ry
May 2006
Introduction
Special lining
panels
The total
envelope
solution
every application.
Product Selector
Product Selector
Product Selector
Trisomet and Trimapanel foam-filled composite panels
acoustic performance.
through fix.
to your projects.
and the joint detail, together with the foam formulation, provide
an economical price.
(LPCB)
Panel Engineering - Weather tight and thermally efficient
System: Trimapanel
Cheltenham racecourse.
System: Guardian
and reassurance
Colorcoat
pre-finished steel
Confidex Guarantee
guidance.
Topcoat
Primer
Pre-treatment
Metallic coating
Substrate
Metallic coating
Pre-treatment
Primer
Backing coat
Colorcoat Celestia
Colorcoat Prisma
Colorcoat Armacor
Confidex
Guarantee
to leathergrain plastisols.
System: Trimapanel
Colorcoat Product: Celestia in Aquarius
Trisomet
Trisomet
Trisomet
Trisomet Specification
Application
External Finish
Internal Finish
External Face
Profiled (1000/32)
Internal Face
Planked
Standard Width
1000mm
Max Length
14000mm
External Gauge
0.5mm Steel
Internal Gauge
0.4mm Steel
Thickness U Value
Weight
Insulant
Acoustic Properties
Robust Details
Robust Details
Extension plate
1.6mm galvanised
standard 3m length
Parapet
Rooflight
Trisomet
10mm
10 x 5mm PE foam
tape, laid continuously
to ensure air tightness
Profiled filler
sealed top
and bottom
Site applied
Insulation
board
10mm
End lap
150mm
minimum
End lap
150mm
minimum
Rooflight
Trisomet
4o min
pitch
4o min
pitch
80mm
Purlin
by others
50 x 5mm PE foam
tape, continuously
laid to ensure air
tightness
10 x 5mm PE foam
tape (3 runs). Do not
lay over the top of the
end crown (as shown
layout on page 18)
Purlin
by others
50 x 5mm PE
foam tape,
continuously
laid to ensure air
tightness
Extension plate
1.6mm
galvanised
standard 3m
length
Roof Ridge
Purlin by
others
Profiled
Filler sealed
top and
bottom
= 0.009 W/mK
f = 0.975
= 0.071 W/mK
f = 0.95
10mm
End lap
150mm
minimum
25mm
60mm
minimum
4o min
pitch
50 x 5mm PE foam
tape, continuously
laid to ensure air
tightness
Injected
foam
10 x 5mm PE
foam tape,
continuously
laid to ensure
air tightness
Insulated membrane
lined gutter
10 x 5mm PE foam
tape, continuously
laid to ensure air
tightness
Robust Details
Robust Details
Eaves
Gutter and eaves
flashing fixing in
every trough
Internal Corner
Gutter support bracket 1 metre spacing and
either side of gutter joint. Rivets/Stitching
Screws 3 per Support Bracket
External Corner
Top sheet cut
back on site
to avoid cold
bridge
= 0.041 W/mK
f = 0.96
= 0.019 W/mK
f = 0.94
= 0.126 W/mK
f = 0.97
Loose laid
insulation
External corner
flashing butt or lap
jointed with two
continuous beads of
high performance
strip sealant 9 x 3mm
Flashing to be stitched
using sealed rivets or self
drilling fasteners with
sealing washers no greater
than 400mm centres
Profiled filler
sealed top and
bottom
Internal flashing
stitched to
underside of the
panel using rivets
at a minimum of
400mm centres.
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 450mm centres
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 450mm centres
Continuous PVC
expandable foam seal
between wall and
internal flashing
Masonry
fastener
Continuous PVC
expandable foam
seal between wall
and internal flashing
Lead flashing/
Cover
Flashing
= 0.26 W/mK
f = 0.84
= 0.26 W/mK
f = 0.84
Cantilever gutter
ref. CCG
Sealed using
10 x 5mm
PE foam tape,
continuously laid
to ensure air
tightness
Closure flashing
butt or lap jointed.
Sealed with two
runs of continuous
high performance
strip sealant 9 x
3mm
Sealed using
10 x 5mm
PE foam tape,
continuously laid
to ensure air
tightness
Internal flashing
Flashing to be
Primary fastener,
stitched to
stitched using sealed 5.5mm diameter self
underside of the
rivets or self drilling
drilling austenitic
panel using rivets fasteners with sealing
S.S. high thread
at a minimum of
washers no greater fastener with 19mm
400mm centres. than 450mm centres
sealing washer
Robust Details
Robust Details
Window Sill
Window/Door Head
Primary fastener, 5.5mm
diameter self drilling austenitic
S.S. high thread fastener with
15mm sealing washer
Double
seal
Sill flashing
Window
frame
Mineral
wool
insulation
Mineral
wool
insulation
= 0.72 W/mK
f = 0.62
= 0.28 W/mK
f = 0.69
= 0.30 W/mK
f = 0.82
= 0.352 W/mK
f = 0.73
Drip flashing
Window
frame
Seal between
window and rail
Window Jamb
Primary fastener, 5.5mm
diameter self drilling austenitic
S.S. high thread fastener with
15mm sealing washer
Primary fastener,
5.5mm diameter self
drilling austenitic S.S.
high thread fastener
with 15mm sealing
washer
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 400mm centres
Drip
flashing
fixed to
panel using
a colour
match rivet
at 400mm
centres
Primary fastener,
5.5mm diameter
self drilling
austenitic S.S.
high thread
fastener with
sealing washer
Support
angle
0.7mm
galvanised
Angle flashing
1.6mm
galvanised
sealed with gun
applied sealant
to base as
shown
Insulation
retaining
flashing
0.7mm
standards
white liner
internal flash
Drip
flashing
fixed to
panel using
a colour
match rivet
at 400mm
centres
Primary fastener,
5.5mm diameter
self drilling
austenitic S.S.
high thread
fastener with
sealing washer
Soffit
flashing
Support
angle
0.7mm
galvanised
Insulation retaining
flashing 0.7mm
standards white
liner internal flash
Verge Detail
Sealed using
10 x 5mm PE foam
tape, continuously laid
to ensure air tightness
Continuous high
performance strip
sealant 3mm
diameter bead
= 0.019 W/mK
f = 0.95
= 0.466 W/mK
f = 0.73
Jamb flashing
Window
frame
Profiled filler
sealed top
and bottom
Cleader
Sealed using
10 x 5mm PE foam
tape, continuously laid
to ensure air tightness
Purlin
Internal flashing
stitched using rivets
no greater than
450mm centres
Trisomet
Trisomet RTS
Roof Tile Support
Trisomet RTS, roof tile support system offers an
Below: Warehouse,
Port Talbot, South Wales.
Frequency(Hz)
AR1-LP
Trisomet
50
45
5000
Span Tables
4
2
1
2
Thickness
Steel Gauge
Self Weight
Span Condition
1.2m
1.4m
1.6m
1.8m
2.0m
2.2m
2.4m
2.6m
2.8m
3.0m
3.2m
3.4m
3.6m
3.8m
4.0m
4.2m
4.4m
5.56
4.85
4.26
3.78
3.37
3.03
2.73
2.47
2.19
1.94
1.73
1.55
1.40
5.00
4.21
3.61
3.15
2.79
2.49
2.25
2.04
1.87
1.72
1.59
1.48
1.38
5.56
4.71
4.04
3.52
3.11
2.79
2.52
2.29
2.10
1.93
1.73
1.55
1.40
5.44
4.87
4.38
3.96
3.55
3.08
2.70
2.38
2.13
1.19
1.72
1.57
1.43
4.02
3.53
3.14
2.82
2.55
2.33
2.14
1.97
1.83
1.71
1.60
1.50
1.41
4.42
3.88
3.45
3.10
2.81
2.57
2.31
2.19
2.04
1.90
1.72
1.57
1.43
Trimapanel
Trimapanel
Trimapanel
Trimapanel Specification
Application
External Finish
Internal Finish
External Face
Micro-rib or planked
Internal Face
Planked
Standard Width
1000mm
Non-standard Width
600mm, 900mm
Max Length
10000mm
External Gauge
Internal Gauge
0.4mm Steel
*Thickness U Value
Weight
Insulant
Acoustic Properties
steel in Europe.
The inner face is bright white polyester.
Robust Details
Robust Details
Base Detail
Wall Abutment
Masonry
fastener
Continuous PVC
Internal flashing stitched to underside of the
expandable foam
panel using rivets at a minimum of 400mm
seal between wall
centres. Sealed using continuous high
and internal flashing performance strip sealant 6mm diameter bead
= 0.241 W/mK
f = 0.775
Continuous high
performance
sealant strip,
factory fitted
PIR LPCB
approved core
Material to be
0.40mm thick steel,
with bright white
lining enamel finish
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 500mm centres
Vertical Joint
Trimapanel panel
Primary fastener,
5.5mm diameter
self-drilling austenitic S.S.
high thread fastener for
composite panels with
sealing washer
PIR board
insulation
Gasket (90mm)
Support steelwork
by others
Trimapanel panel
PIR board
insulation
Continuous high
performance strip sealant
6mm diameter bead
Mineral
wool
insulation
= 0.31 W/mK
f = 0.69
Drip flashing
Support steelwork
by others
Mineral
wool
insulation
= 0.31 W/mK
f = 0.80
Angle flashing
1.6mm
galvanised
sealed with gun
applied sealant
to base as
shown
Insulation
retaining
flashing
0.7mm
standards
white liner
internal flash
External Corner
Gasket (90mm)
Continuous high
performance strip sealant
6mm diameter bead
Drip
flashing
Soffit
flashing
Insulation retaining
flashing 0.7mm
standards white
liner internal flash
Internal Corner
Continuous high
performance strip sealant
6mm diameter bead
Support
steelwork
by others.
Continuous high
performance strip sealant
6mm diameter bead
Support
steelwork
by others
As shown
= 0.019 W/mK
f = 0.950
Without Liner
cut back
= 0.177 W/mK
f = 0.775
As shown
= 0.001 W/mK
f = 0.975
Without External
Sheet cut back
= 0.147 W/mK
f = 0.805
= 0.001 W/mK
f = 0.975
Primary fastener,
5.5mm diameter
self-drilling austenitic
S.S. high thread
fastener for
composite panels
with sealing washer
35mm crown
gasket, site
applied.
= 0.001 W/mK
f = 0.975
Primary fastener,
5.5mm diameter
self-drilling austenitic
S.S. high thread
fastener for
composite panels
with sealing washer
CP&P flashing to be
stitched using sealed rivets
or self drilling fasteners with
sealing washers at not
more than 450mm centres
Continuous high
performance strip
sealant 6mm
diameter bead
CP&P flashing to be
stitched using sealed rivets
or self drilling fasteners with
sealing washers at not
more than 450mm centres
Continuous high
performance strip
sealant 6mm
diameter bead
Robust Details
Span Tables
Window Sill
Window/Door Head
Primary fastener, 5.5mm
diameter self drilling austenitic
S.S. high thread fastener with
15mm sealing washer
Continuous high
performance strip
sealant 6mm
diameter bead
Ferrules
use to fit
window
Internal head
flashing with no
connection to
external soffit
Window
frame
Ferrules
use to fit
window
25mm
PIR
insulation
= 0.72 W/mK
f = 0.62
= 0.352 W/mK
f = 0.73
Head flashing
5 slope for
drainage
25mm PIR
insulation
External soffit
flashing with
no connection
to internal
flashing
CP&P stainless
steel base
support clip at
ends of panels
and 1500 centres
max between
Window
frame
Window Jamb
Primary fastener, 5.5mm
diameter self drilling
austenitic S.S. high thread
fastener with sealing washer
Sill flashing
5 slope for
drainage
(no connection
to internal
flashing)
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 400mm centres
Continuous high
performance
strip sealant
6mm diameter
bead
PIR
insulation
Parapet
Ferrules
use to fit
window
25mm
PIR
insulation
Reveal flashing
with no connection
to external reveal
flashing
Site
Parapet flashing butt or lap
Primary fastener, 5.5mm
Profiled applied jointed sealed with two runs of
diameter self drilling
Insulation continuous high performance austenitic S.S. high thread
filler
board
block
strip sealant 9 x 3mm
fastener with sealing washer
Window
frame
= 0.466 W/mK
f = 0.73
Window reveal
flashing with
no connection
to internal
flashing
Trisomet panels
Insulated
membrane
lined gutter
Continuous high
performance
strip sealant
6mm diameter
bead
Flashing to be stitched
using sealed rivets or
self drilling fasteners
with sealing washers
no greater than
450mm centres
Section heading
(running
Guardian
Rockfibre
panelsheader)
Introduction
Guardian
Product
Fire resistant
LPCB approved system
Weather-tight and thermally
efficient construction
Acoustically efficient
Building regulations L2 compliant
Aesthetically pleasing appearance
Comprehensive and robust warranties
Quality assured manufacture
Guardian TF
120mm
135mm
120mm
Application
135mm
Colorcoat Prisma ,
Colorcoat HPS200,
Colorcoat Celestia,
Smooth Bright
White Polyester
Colorcoat Prisma ,
Colorcoat HPS200,
Colorcoat Celestia,
Smooth Bright
White Polyester
Colorcoat Prisma,
Colorcoat HPS200,
Colorcoat Celestia,
Smooth Bright
White Polyester
External Face
Microrib or Planked
Microrib or Planked
Microrib or Planked
Microrib or Planked
Internal Face
Planked
Planked
Planked
Planked
Standard Width
1000mm
1000mm
1150mm
1150mm
Non-Standard Width(mm)
600mm or 900mm
600mm or 900mm
1000mm
1000mm
9000mm
9000mm
9000mm
9000mm
0.7mm
0.7mm
0.7mm
0.7mm
0.6mm
Thermal Conductivity
0.35W/m K
Weight
24.88kg/m
Insulant
Rockfibre
Acoustic Properties*
34db
Fire Performance**
60 minutes insulation
and integrity
LPS 1181 Grade A
0.6mm
2
0.6mm
2
0.6mm
2
0.30W/m K
0.35W/m K
0.30W/m K
26.53kg/m
24.88kg/m
Rockfibre
34db
Colorcoat Prisma ,
Colorcoat HPS200,
Colorcoat Celestia,
Smooth Bright
White Polyester
External Finish
Internal Finish
Guardian SF
Thickness
26.53kg/m
Rockfibre
34db
90 minutes insulation
and integrity
LPS 1181 Grade A
Rockfibre
34db
60 minutes insulation
and integrity
LPS 1181 Grade A
90 minutes insulation
and integrity
LPS 1181 Grade A
Calculated figures.
**
Guardian SF
Guardian TF
1000mm
cover width
1150mm
cover width
120mm
120mm
Robust Details
Robust Details
Base Detail
Continuous high
performance strip sealant
6mm diameter bead
Mineral
wool
insulation
= 0.29 W/mK
f = 0.69
Insulation core to
be conrock 10,
110kg/m3 density
Rockfibre
Material to be
0.6mm thick steel,
with bright white
lining enamel finish
Wall Abutment
Continuous PVC
expandable foam seal
between wall and flashing
Material to be
0.6mm thick steel,
with bright white
lining enamel finish
Insulation core to
be conrock 10,
110kg/m3 density
Rockfibre
Vertical Joint
Site seal horizontal joint at
position perpendicular with inner
seal with gun mastic to create air
seal between steel interlocks
Support
steelwork
by others
Trimapanel panel
Drip flashing
Gasket (90mm)
Support steelwork
by others
Mineral
wool
insulation
= 0.30 W/mK
f = 0.78
CP&P support
angle flashing
1.6mm
galvanised
sealed with gun
applied sealant
to base as
shown
Insulation
retaining
flashing
0.7mm
standards
white liner
internal flash
Continuous high
performance strip sealant
6mm diameter bead
Drip
flashing
Soffit
flashing
Insulation retaining
flashing 0.7mm
standards white
liner internal flash
Support
steelwork
by others.
Support
steelwork
by others.
Continuous high
performance strip
sealant 6mm
diameter bead
Insulation
infill
As shown
= 0.019 W/mK
f = 0.950
Without Liner
cut back
= 0.177 W/mK
f = 0.775
= 0.241 W/mK
f = 0.775
As shown
= 0.001 W/mK
f = 0.975
Without External
Sheet cut back
= 0.147 W/mK
f = 0.805
= 0.001 W/mK
f = 0.975
Gun applied
silicone
sealant
CP&P flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers at not more
than 500mm centres
Primary fastener,
5.5mm diameter
self-drilling austenitic
S.S. high thread
fastener for
composite panels
with sealing washer
Primary fastener,
5.5mm diameter
self-drilling austenitic
S.S. high thread
fastener for
composite panels
with sealing washer
CP&P flashing to be
stitched using sealed rivets
or self drilling fasteners with
sealing washers at not
more than 500mm centres
Continuous high
performance strip
sealant 6mm
diameter bead.
Factory made,
external corner
mitred composite
panel piece
35mm crown
gasket, site
applied.
Aluminium
top hat extrusion.
Robust Details
Span Tables
Internal Corner
Internal flashing sealed
at all joints to ensure
continuation of air seal
Window/Door Head
Primary fastener, 5.5mm
diameter self drilling austenitic
S.S. high thread fastener with
15mm sealing washer
Continuous high
performance strip
sealant 6mm
diameter bead
Continuous high
performance strip
sealant 6mm
diameter bead
Span
(m)
= 0.72 W/mK
f = 0.62
2.0
As shown
= 0.001 W/mK
f = 0.975
Without External
Sheet cut back
= 0.147 W/mK
f = 0.805
Suction Loads
Imposed Loads
2
Single Span
L/150
Loads kN/m
Double Span
L/150
Multi Span
L/150
4.07
3.85
3.60
CP&P flashing to be
stitched using sealed rivets
or self drilling fasteners with
sealing washers at not
more than 450mm centres
Continuous high
performance strip
sealant 6mm
diameter bead
Window Sill
Window
frame
Head flashing
5 slope for
drainage
Rockfibre
slab
External soffit
flashing with
no connection
to internal
flashing
CP&P stainless
steel base
support clip at
ends of panels
and 1500 centres
max between
Loads kN/m2
Double Span
L/150
Multi Span
L/150
2.0
4.07
3.85
3.60
3.90
3.26
2.88
2.5
3.90
3.26
2.88
2.5
3.0
3.27
2.31
2.35
3.0
3.27
2.31
2.35
2.39
1.72
NA
3.5
2.39
1.72
NA
3.5
4.0
1.81
1.31
NA
4.0
1.81
1.31
NA
1.40
1.03
NA
4.5
1.40
1.03
NA
4.5
5.0
1.11
0.82
NA
5.0
1.11
0.82
NA
0.89
0.40
NA
5.5
0.89
0.40
NA
5.5
6.0
0.71
0.30
NA
6.0
0.71
0.30
NA
6.5
0.58
0.24
NA
7.0
0.47
0.19
NA
6.5
0.58
0.24
NA
7.0
0.47
0.19
NA
Single Span
L/150
Span
(m)
Window
frame
Window Jamb
Loose laid
insulation
Ferrules
use to fit
window
Rockfibre
slab
Ferrules
use to fit
window
= 0.352 W/mK
f = 0.73
Rockfibre
slab
Reveal flashing
with no connection
to external reveal
flashing
Window
frame
= 0.466 W/mK
f = 0.73
Sill flashing
5 slope for
drainage
(no connection
to internal
flashing)
Flashing to be
stitched using sealed
rivets or self drilling
fasteners with sealing
washers no greater
than 400mm centres
Continuous high
performance
strip sealant
6mm diameter
bead
Rockfibre
slab
Flashing to be stitched
using sealed rivets or
self drilling fasteners
with sealing washers
no greater than
450mm centres
Continuous
high
performance
strip sealant
6mm diameter
bead
Window reveal
flashing with
no connection
to internal
flashing
Handling
Handling
Corus Guarantees
to materials.
period.
requirements.
including:
Contractors.
Corus Guarantees
Corus Guarantees
Guardian SF & TF
insured buildings.
Profiles Composite
stage.
LPS 1181
(Loss Prevention
LPS1181:2003
Certificate No. 460A/07,
08, 09, 10, 11, 12 & 13
be acceptable in a combustible
areas.
vertically.
Certification Board)
Construction Methods.
Factory Mutual
0.9kN.
requirement.
area.
areas:
impactor.
www.coruspanelsandprofiles.co.uk
Care has been taken to ensure that this
information is accurate, but Corus Group Plc,
including its subsidiaries, does not accept
responsibility or liability for errors or
information which is found to be misleading.
Suggestions for, or descriptions of, the end
use or application of products or methods of
working are for information only and Corus
UK Limited and its subsidiaries accept no
liability thereof. Before using products
supplied or manufactured by Corus UK Ltd
and its subsidiaries the customer should
satisfy themselves of their suitability.
Trisomet, Trimapanel, Guardian,
Celestia, Colorcoat, Confidex, HPS200,
Prisma, Armacor, Colorcoat connection and
Repertoire are registered trademarks of
Corus.
Copyright 2006
Corus
Designed by Plum Design & Advertising
CP&PR&W09:3000:UK:05/2006