requirements demanded by carrier network, MAN access. S5750E-SI Series switch offers green features like IEEE
802.3az (Energy Efficient Ethernet), Fan-less design and Smart Fan feature, which can dramatically lower power
consumption, achieve green energy and save the cost for the carrier and MAN users.
S5750E-SI Series has 6 types including S5750E-28P-SI, S5750E-52P-SI, S5750E-28X-SI, S5750E-52X-SI,
S5750E-28P-P-SI and S5750E-28X-SI-24F-D. Equipped with the full GE ports and 4 SFP/SFP+ uplink ports, the
series integrates advanced management and security functions to provide performance and scalability.
Main Features
Green Energy
S5750E-SI series complies with IEEE 802.3az (Energy Efficient Ethernet Energy-Efficient Ethernet)
standard, dramatically lower power consumption
With Innovative port-LED Shut-off function, the user can automatically set the switch port-LED UP
or DOWN at a specified time period according to their needs to achieve functional, energy-saving
correct results.
Full account of low noise requirements of the environment, S5750E-28P-SI and S5750E-28X-SI use
Fanless Design and other models use Smart Fan strategies to control fan speed according to
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
1/8
real-time temperature monitoring system which can effectively reduce speed, extend fan life and
reduce noise pollution.
Enhanced Security
S5750E-SI series provides a variety of security mechanisms like SYN Flood, Land, ICMP Flood
attack prevention and other DOS class technology, BPDU Guard and Root Guard which avoid
accidental topology loops and prevent illegal edge devices become root to cause unnecessary
flapping.
IEEE 802.1X port-based access control ensures all users are authorized before being granted
access to the network. User authentication is carried out using any standard-based RADIUS server.
Access Control Lists (ACLs) can be used to restrict access to sensitive network resources by
denying packets and forward by different policies. User-defined ACL provides more flexible access
control for users.
S5750E-SI series support DHCP snooping, which prevents DHCP attacks and illegal DHCP
SERVER by setting trust ports and untrust ports. With DHCP Snooping binding and option82 enabled,
it can combine modules like dot1x and ARP, or implement user-access-control independently.
S5750E-SI series supports much more L2 security features such as ARP guard, Anti-ARP
scanning, and other ARP and MAC Security technology to protect network security and reliability.
High Reliability
S5750E-SI series supports 4 Gigabit or 10Gigabit uplink ports, which could be designed to offer
redundant uplinks with various ring protection applications, effectively raised the expansibility and
performance of network.
G.8032 provides sub-50ms protection and recovery switching for Ethernet traffic in a carrier ring
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
2/8
topology. S5750E-SI series supports G.8032 v2 and can be deployed in a variety of complex network
topologies including single ring, tangent ring, intersecting rings, double rings and other home
networking.
Multi-process MSTP*. When a new access ring can be implemented through creating a new
process of MSTP, the new ring does not affect the existing traffic. And each process may run different
spanning tree protocol.
DCN EMVTE technology (Enhanced Multi-VLAN subnet Traffic Engineering) is a multi-link backup
and load balancing solution based on multiple VLAN subnets for dual homing network. It can achieve
faster switching and convergence of the uplink through ULPP (Uplink Protection Protocol) and ULSM
(Uplink State Monitor) protocol so that network performance is guaranteed.
Built-in 6K lightning protection for ports on S5750E-SI series effectively resists lightning, reduces
equipment damage significantly.
POE+ support
The S5750E-28P-P-SI can support PoE (Power over Ethernet) technology and provide remote power
to wireless AP, IP phone and Network Camera. The network can help administrators to easily deploy
cable.
With both 802.3af and 802.3at support, the S5750E-28P-P-SI can support 24 port PoE at same time
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
3/8
and the MAX power of each port up to 15.4W or 12 ports up to 30W . The product can define the
power of each port to save the power and set port priority for each port.
Total PoE power 370
Specifications
S5750-28X-SI-24F-D
S5750-28X-SI
S5750-52X-SI
Item
S5750E-28P-SI
S5750E-52P-SI
S5750E-28X-SI
S5750E-52X-SI
S5750E-28P-P-SI S5750E-28X-SI-24F-D
1 Console port
1 Console port
1 Console port
1 Console port
1 Console port
48 x
24 x
48 x
24 x
20 x 100/1000Base-X
+ 4 x 1000Base-X
+ 4 x 10GbE
+ 4 x 10GbE
+ 4 x 1000Base-X
Combo(RJ45/SFP) + 4
(SFP)
(SFP)
(SFP+)
(SFP+)
(SFP)
x 10GbE (SFP+)
104Gbps
128Gbps
176Gbps
56Gbps
128Gbps
Performance
Switching Capacity 56Gbps
Forwarding Rate
42Mpps
78Mpps
96Mpps
132Mpps
42Mpps
96Mpps
MAC ADDRESS
16K
16K
16K
16K
16K
16K
Jumbo Frame
9K
9K
9K
9K
9K
9K
ACL Table
1k
1k
1k
1k
1k
1.5k
128 / 128
128 / 128
128 / 128
128 / 128
128 / 128
512 / 512
4K
4K
4K
4K
4K
4K
Route Table
IPv4 / IPv6 shared
Queues per port
VLAN TABLE
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
4/8
Item
S5750E-28P-SI
S5750E-52P-SI
S5750E-28X-SI
S5750E-52X-SI
S5750E-28P-P-SI S5750E-28X-SI-24F-D
Physical
443mm x 44mm x 443mm x 44mm x 443mm x 44mm x 443mm x 44mm x 443mm x 44mm x 443mm
Dimension(WHD) 230mm
280mm
230mm
280mm
330mm
220mm
44mm
weight
2.42kg0.1kg
4.70kg0.1kg
2.42kg0.1kg
4.70kg0.1kg
4.75kg0.1kg
2.8kg0.1kg
Power Input
100~240VAC,
100~240VAC,
100~240VAC,
100~240VAC,
100~240VAC,
AC: 100~240VAC,
50~60Hz
50~60Hz
50~60Hz
50~60Hz
50~60Hz
50~60Hz
DC: Input -48V ~ -60V
Power Consumption
MTBF
37W
23W
37W
420W
42W
>80,000 hours
Temperature
Relative Humidity
EMC safety
20W
5%~95%,non-condensing
CE, RoHS
NA
NA
NA
NA
POE+ (30W)
Global / port POE
function control
Total PoE power:
370W
Main Features
Forwarding
VLAN
Voice VLAN
MAC VLAN
Normal QinQ, Selective QinQ, Flexible QinQ
VLAN Translation, N:1 VLAN Translation
IPv4/IPv6 DHCP Client,IPv4/IPv6 DHCP Relay
DHCP
Option 82,Option 37/38
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
5/8
NA
Item
S5750E-28P-SI
S5750E-52P-SI
S5750E-28X-SI
S5750E-52X-SI
S5750E-28P-P-SI S5750E-28X-SI-24F-D
Spanning
Root Guard, BPDU Guard, BPDU Forwarding
Tree
Multi-Process MSTP*
128 groups per device/8 ports per group
LACP
Load balance
MRPP
Reliability L2 Ring ITU-T G.8032
Protection Loopback Detection
Fast Link
Multi-link
Backup
Enhanced Multi-VLAN subnet Traffic Engineering (ULPP+ULSM)
and Load
Balance
IP ACL, MAC ACL, MAC-IP ACL, User-Defined ACL
Time Range ACL
ACL on VLAN interface
Storm Control based on packets and bytes
Port Security, MAC Limit based on VLAN and Port
Security
Multicast
MLD v1/v2 snooping
IPv4/IPv6 DCSCM(D)
8 Queues Per Port
Bandwidth Control
QoS
Flow Redirect
Classification based on ACL, VLAN ID, COS, TOS, DSCP, IPv6 Flow Label
Policing Based on Port and VLAN
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
6/8
Item
S5750E-28P-SI
S5750E-52P-SI
S5750E-28X-SI
S5750E-52X-SI
S5750E-28P-P-SI S5750E-28X-SI-24F-D
Single Rate Three Colors, Dual Rates Three Colors for Policing
Remark DSCP, COS/802.1p, Precedence, TOS
SP, WRR, SWRR, DWRR for Scheduling
XModem/TFTP/FTP
CLI, Telnet, Console
Web/SSL (IPv4/IPv6)
SSH (IPv4/IPv6)
SNMPv1/v2c/v3
SNMP Trap
Public & Private MIB interface
RMON 1,2,3,9
Ping, Trace Route
Maintenance and
Operation
Radius Authentication
Syslog (IPv4/IPv6)
Management
SNTP/NTP (IPv4/IPv6)
Dual IMG, Multiple Configuration Files
Port Mirror, CPU Mirror, RSPAN, ERSPAN
sFlow
OAM*
Dying GASP
VCT, DDM
ULDP(like Cisco UDLD)
LLDP/LLDP MED
OpenFlow 1.0, support open controller OpendaylightFloodlightRyuPox, etc.
IEEE 802.3az (Energy Efficient Ethernet)
Green Energy
Auto Fan Speed Control, Temperature Alarm (S5750E-28P and S5750E-28X has no fans)
LED Shut-off
Ordering information
Product
S5750E-28P-SI
Description
S5750E-52P-SI
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
7/8
S5750E-28X-SI
S5750E-52X-SI
S5750E-28P-P-SI
Gigabit
Intelligent
Ethernet
Switch
with
24
10/100/1000Base-T
and
S5750E-28X-SI-24F-D
100/1000Base-X(SFP) ports, 100-240VAC Power Input, 30w PoE+ supported and total
Connect us
For more detail information about DCN product, contact:
URL: http://www.DCNglobal.com
Email: sales@DCNglobal.com
Address: Digital Technology Plaza, NO.9 Shangdi 9th Street, Haidian District, Beijing, China
2014 Digital China Networks Inc All rights reserved. This document is DCN Public Information
All specifications are subject to change without further notice. All features with * mark will be available by firmware upgrade.
8/8