Fourth-Axis Beta-I Drive Kit User Manual B-165A
Fourth-Axis Beta-I Drive Kit User Manual B-165A
Fourth-Axis Beta-I Drive Kit User Manual B-165A
Installation Instructions
for the Hardinge
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Table of Contents
Safety Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1. Introduction
1.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Set Up
2.4 Mounting the fourth-axis Beta-i drive and dynamic brake resistor. . . . . . . . . . . . . . . . . . . . . 9.
2.6 Connecting the dynamic brake resistor and fiber optic cable. . . . . . . . . . . . . . . . . . . . . . . . 12
2.8 Installing the chassis ground wire and connecting the shield wire of the feedback cable. . . 14
2.11 Preparing the machine for a Hardinge fourth-axis rotary with a 24vdc clamp solenoid . . . 18
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
DONT TOUCH ELECTRICAL EQUIPMENT when hands are wet or when standing on a wet surface.
(Where Applicable)
REPLACE BLOWN FUSES with fuses of the same size and type as originally furnished. (Where Applicable)
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Remove power from the unit by unplugging the power cord before attempting repair or maintenance.
(Where Applicable)
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
VERIFY that the electrical cables are not restrained or pinched during full travel movement of the machine.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Figure
A
B
C
D
E
F
G
Part Number
A06B6130H002
A06B6130H402
Description
20-Amp Beta-i Servo Drive
Dynamic Brake Resistor
Connectors (shown attached)
Chassis Ground Wire
A66L60010026L2R003 Fiber Optic Cable
CI 0003011I36I
Three-Phase Power Cable
CI 0003011I36F
24-Volt Power Cable
CI 0003011I36J
Drive Enable Cable for CE machine
CI 0003011I36E
Drive Enable Cable for non-CE machine
Wire-Joint (not shown)
Large Ty-wrap (not shown)
Small Ty-wrap (not shown)
M4 x .7 x 8mm SHCS (not shown)
Qty
1
1
2
1
1
1
1
1
1
2
2
10
7
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
2. Set Up
2.1 Back up the original machine parameters from the CNC control
Insert a card into the card slot.
The Setting Screen should be set to Channel 4 and set Parameter Write to 1.
(You may need to hit Cancel & Reset to clear an alarm)
Push the System key.
Right arrow until you see the All IO screen, click on All IO screen and go into Edit mode.
Save parameters by selecting parameter, push OPRT, and File Output.
Name the file using the keypad incorporating a (.txt) suffix.
Push F Name to store the name in the alpha file.
Push Execute to save the parameters on the card.
2.2 Powering Down the Machine
E-STOP OFF
Push the E-Stop button on the operator control panel in the front of the machine.
Turn off the control by pushing the OFF button.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Before adding the fourth-axis Beta-i drive, you must power down the machine:
CAUTION: Wait for the light to go out under the Fanuc Beta-I SVPM3 drive package, indicating that the drives have
discharged and the DC output bus has gone to zero. Discharge time could take over two minutes.
2.3 Locating the Fiber Optic Port
NOTE: If the combination drive package on the machine does NOT have a COP10A connection (many older
machines do not), then the fiber optic cable must be removed from the COP10B port on the SVMP3 drive package and
re-attached to the COP10B port on the fourth-axis Beta-i drive. Then the kit provided fiber optic cable is run from
the COP10A port on the fourth-axis Beta-i drive to the COP10B connector on the SVMP3 drive package. This inserts
the fourth-axis Beta-i drive between the Fanuc CNC control and the SVMP3 drive package. In this case there is only
one fiber optic cable on the combination drive package and there are two fiber optic cables connected to the fourthaxis Beta-i drive. The FSSB drive allocation table in the control must then be re-assigned. Please call the factory for
complete instructions.
8
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
The newer Fanuc SVMP3 drive packages have a COP10A and a COP10B fiber optic port to the right of the SVPM3
drive package (yellow box). The COP10A optic port provides the ability to add a fourth-axis after the SVMP3 package.
There are four pre-drilled holes to the left of the yellow SVMP3 drive package that match the footprint of the Beta-i
drive. This is where you will mount the drive. Mount the Beta-i drive using four M4 SHCS screws. Hand-tighten using
an M4 ball-nosed Allen wrench or an 8-inch M4 T-handle Allen wrench.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Crimp pins on the wires and mount them into the plugs
10
Punch indents in the panel on your two marks to aid in the drilling process.
Drill each hole using a #30 tap drill size to thread for M4 x .7 SHCS screws.
Tap each hole.
Screw in the top M4 SHCS screw and slide the resistor into position.
Screw in the bottom screw and hand tighten both screws using an M4 Allen wrench.
Lift the wires and carefully remove the shop rag so that no metal filings are left on the ledge in the power panel.
NOTE: All connectors on the Fourth-Axis Beta-i Drive are keyed and will only plug in one way.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Connect the power cable in the upper two connections labeled L1 and L3 on the left side of the Beta-i fourthaxis drive at connector location CZ7.
Remove the gray terminal cover just below the main terminal box on the SVPM3 drive package and connect the
four terminal connectors as indicated below:
Unscrew the earth terminal and screw in the E (green earth) wire connector to it.
Continue connecting the R8 (black wire), S8 (white wire) and T8 (red wire).
Snap the terminal cover back into position.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
11
Remove the (2) protective vinyl covers from each end of the fiber optic cable.
Remove the COP10B port cover on the Beta-i fourth-axis drive and insert one end of the fiber optic cable
(both ends of the cable are identical).
12
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
The wide connector (black wire) plugs into DCP port or slot 3 of connector CZ7 on the
Beta-i fourth-axis drive.
The thermostat wire connector (white wire) plugs into the bottom left connector labeled CXA20/DCOH
on the Beta-i fourth-axis drive.
Remove the COP10A port cover on the SVMP3 drive package and connect the other end of the fiber optic
cable into the COP10A port.
2.7 Locating and connecting the machine's fourth-axis cables
The machine comes pre-wired with a motor power cable and a feedback cable for the fourth-axis Beta-i drive.
Remove the central wire-way cover and open the plastic bag to locate the two fourth-axis cables.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
NOTE: Early GX production machine prewire kits came with a 40-amp drive motor plug connector on them.
This will have to be removed and replaced with the proper 20-amp drive - motor plug connector. Contact your
machine distributor for a plug replacement kit.
13
The motor power cable plugs into the remaining lower three slots of the CZ7 plug and the feedback cable plugs into
the JF1 terminal on the Beta-i fourth-axis drive. The light green shield wire will be connected in the next section.
Push the two cables in between the wireway fingers and snap the wireway cover back temporarily into position
to prevent other cables and wires from falling out.
2.8 Installing the Chassis Ground Wire and connecting the Shield Wire of the Feedback Cable
Attach one end of the ground wire to the ground screw connection under the base of the Beta-i Drive using
an M4 SHCS screw.
Attach the other end to the ground screw on the SVMP3 drive package as shown. The SVMP3 ground screw
will have another ground wire with the E (earth) wire label.
14
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Snip the nylon ty-wrap to release the light green shield cable from the feedback cable that is connected in the JF1 port
of the Beta-i Drive. Wrap the wire around the feedback cable a couple of times and connect it to any available terminal on the ground terminal block located below the wireway cover to ground the shielding of the feedback cable.
Plug the single connector into the CXA19B connector on the upper right side of the Beta-i fourth-axis drive.
Run the wire through the wireway fingers and run them down to the lower plastic covered terminal block in the
bottom left area of the power panel. Remove the plastic terminal cover and the wireway cover.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
15
Hook the red wire to the P24 terminal and the black wire to the 0VP terminal, and tighten them down with
a screwdriver.
16
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
Plug the appropriate drive enable cable into the CX30 connector on the lower left side of the Beta-i fourth-axis
drive. Run the cable down through the wireway fingers and over to the top row of terminals on the relay module
located on the left wall of the main enclosure.
The red wire from the cable must be connected with a wire joint to either 212 (non-CE) or 225 (CE).
The black wire from the cable must be connected with a wire joint to wire 216 in either the CE or non CE machine.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
17
18
Remove the wireway cover of the vertical wireway located on the left wall of the power panel.
Fish out the cable labeled 4 Axis Power and trace the wire that is plugged into the #211 terminal on the bottom
row of terminals on the relay module.
Remove the wire from terminal #211 and move it to the 0VC terminal to the left of the original position.
Hardinge geared tables other than the 5C use a 24vdc clamp solenoid.
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
2.11 Preparing the machine for a fourth-axis Hardinge Rotary with 24vdc clamp solenoid
(skip this section if installing a 5C rotary indexer with no clamp)
There are two jumpers on the relay module that must be set.
Set JP1 to 190B for geared rotary tables.
Set JP7 for +24VA.
Clean up all wire routing.
______________________________________________
______________________________________________
______________________________________________
Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 (Canada 800.468.5946) www.shophardinge.com
A separate setup sheet is included that applies to GX 480 machine and your specific rotary table model.
19
Hardinge Inc. One Hardinge Drive | P.O. Box 1507 | Elmira, New York 14902-1507 USA
USA: 800-843-8801 | Canada: 800-468-5946 | Fax: 607-734-3886
To Order Online: www.shophardinge.com | Corporate Homepage: www.hardinge.com | E-mail: info@shophardinge.com | Live Online Support: www.shophardinge.com
All specifications are subject to change without notice due to ongoing continuous improvement. All marks indicated by and are trademarks of Hardinge Inc.
Instruction Manual B-165 Litho in USA Hardinge Inc. 2012