Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Brosur Aeon8600A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Aeon8600A

Anaesthesia Workstation

PCV and SIMV+PS modes ensure flexibility in ventilation,


machine doable for both pediatric and adult operation
Optional functions monitoring O 2, CO 2 ,and anesthetic gas
Flowmeter provides minimum 25% concentration of oxygen
in O 2 /N 2O mixture
Absorb system sterilized with high temperature and high
pressure
Enhances usability with auxiliary oxygen, suction, auxiliary
power source, monitor arm, infusion pump etc.

CE marked, meets EU clinical requirement

An ISO9001/13485 Company

Technical Specifications
Physical & Environment Specifications
Dimensions(WHD):
Weight:
Operation Temperature:
Operation Humidity:
Storage Temperature:
Storage Humidity:

704mm 1403mm 750mm


115kg (including trolley base and 2 vaporizers, without cylinder)
+10~+40C
80% (noncondensing)
-20~+55C
93%(noncondensing)

Electrical Specifications
Mains:
Battery:

100-240V AC, 50-60Hz


24V 5Ah, minimum 120 min

Pneumatic Specifications
Gas Supply :
Flowmeters:

Gas System:

Air,O 2 ,N 2 O; 280kPa - 600kPa


O 2 Range: 0-1L/min; 1-10L/min
N 2 O Range: 0-1L/min; 1-10L/min
Air Range: 0-1L/min; 1-12L/min
Auxiliary O 2 Range: 0 -15 L/min
Flowmeter backlight
Low O 2 signal
N 2 O-cut-off system
O 2 flush: 25-75L/min

Breathing System Specifications


Operational Modes:
Closed, Semi-closed, Semi-open
Carbon Dioxide Absorbent Canister: 2 Loose fill(3L) or 2 prepacks
APL Range:
Spontaneous breathing (SP) -70 cmH 2 O
Material:
Autoclavable (except flow sensors, O 2 fell cell and mechanical pressure meter)

Ventilator Specifications
Driven Modes:
Pneumatically driven and electronically control
Patient Types:
Adult, Pediatric
Ventilation Modes:
IPPV, PCV, SIMV, PS, and Manual
Setting Modes:
Touch key & navigator wheel knob
Tidal Volume:
20-1500ml
Ventilation Frequency:
4-100bpm
I:E Ratio:
4:1-1:8
Pressure (inspired) Range:5-70cmH 2 O
Pressure (support) Range: 3- 50cmH 2 O
Ppeep:
off,3-30 cmH 2 O
Tslope:
0-2s
Inspiratory Plateau:
off, 5%-60%Ti,
Trigger Sensitivity:
1-15L/min
Peak Gas Flow:
75 L/min
Compensation:
Compliance compensation, fresh gas compensation

Ventilator Monitoring
Display:
Pressure:
Volumes:
Gas:
Graph Display:

10.4 TFT color screen


Paw, Peak, Pplat, Pmean, PEEP
MV, Vt
O 2 Concentration, CO 2 Concentration, Anaesthesia Agent Concentration
P-T, F-T&P-V,F-V loops(can be saved), Wave of CO 2

Alarm
Pressure:
Paw high/low limit
Volumes:
MV high/low limit,
Gas:
FiO 2 high/low limit
Power failure
Apnea Alarm: 60 seconds
Alarm Silence:110 seconds

Vaporizer
Support two vaporizers
Agent:
Halothane, Enflurane, Isoflurane , Sevoflurane.
Installation Mode: Selectatec with interlock
Filling Type:
Pour Fill, Key Fill, Quik-Fil
Remark: Above configurations include standard and option. Please check price with your Aeonmed sales representative.

Beijing Aeonmed Co.,Ltd.

Office (Headquarters):
Add:11B2, Fengtai Science Park,(100070) Beijing, China
Tel: +86-10-8368 1616
Fax: +86-10-6371 8989
http: //www.aeonmed.com
E-mail:int@aeonmed.com

Information contained in this leaflet is correct at the date to publication. The policy of Beijing Aeonmed Co., Ltd. is one of the continued improvement to its products .
Because of this policy Beijing Aeonmed Co., Ltd. reserves the right to make any change, which may affect the information in this leaflet without giving prior notices.
Print in July.2012