ANC-100e RSLINX Ethernet IP To DH+ User Manual-RevM3A2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

ANC-100e User Manual

ANC-100e
Ethernet to Data Highway Plus
Adapter
User Manual

About ANC-100e
The ANC-100e allows you to connect a computer or other Ethernet Processors or HMI to a DH+
network and communicate with various DH+ enabled devices such as Allen Bradleys PLC5, SLC5/04,
SLC5/05, ControlLogix series and other devices which might support Allen Bradley DH+ network
connectivity.
ANC-100e is designed to work utilizing the Ethernet/IP network driver available in most industrial
communication software suites, such as Allen Bradley RSLinx Classic/Gateway/Enterprise and alike. And
its auto-configuration features provide a quick and easy connection, as cable polarity, node number
and baud rate can be auto-detected. For more information on properly configuring your software suite
of choice to work with ANC-100e, please see the corresponding chapter of this manual.

ANC-100e
Ethernet to DH+ Adapter

User Manual 2

Table of contents
ANC-100E ETHERNET TO DATA HIGHWAY PLUS ADAPTER
USER MANUAL........................................................................... 1
ABOUT ANC-100E....................................................................... 1
TABLE OF CONTENTS ................................................................... 2
NETWORK ADAPTER CONFIGURATION .......................................... 3
USING ANC-100E ....................................................................... 6
Connections ........................................................................................ 6
LED Diagnostics .................................................................................. 6
Accessing ANC-100e User Interface ................................................... 6

CONFIGURATION AND INTERFACE ................................................. 8


Device Settings ................................................................................... 8
Automatic DH+ node assignment: ....................................................................... 8
Automatic DH+ Baud Rate detection: .................................................................. 8
Automatic Polarity detection ................................................................................ 8

Main Configuration Window................................................................. 8


Device Password................................................................................. 9
Firmware Upgrade..............................................................................10
Statistics .............................................................................................11
Language ...........................................................................................11

RESET TO DEFAULT FACTORY SETTINGS: ................................... 12

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 3

Network Adapter Configuration


The default IP address of the device is set to 192.168.137.2.
The first time the device is used, it is required to configure the network adapter in your computer to
use a static IP address in order to access the ANC-100e web configuration interface.
1. Open Windows Control Panel
2. Click on Network and Internet

3. Click on Network and Sharing Center

4. Click on Change adapter settings

5. Locate the network adapter where ANC-100e can be reached. Please note, Windows OS
can assign any number after Local Area Connection label, in our particular example,
Windows OS had assigned a number 2 to our network adapter, hence it is displayed as
Local Area Connection 2, but it can be different in your case
6. Right click on the corresponding network adapter
7. Click on Properties

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

8. From the list of items, select Internet Protocol Version 4 (TCP/IPv4)


9. Click Properties button

10. Select the option Use the following IP address


11. Configure the adapter to use following settings:
IP address: 192.168.137.1
Subnet Mask: 255.255.255.0
12. Leave the Default gateway and DNS server settings blank
13. Click OK button

Automation Network Inc. 2016

User Manual 4

ANC-100e
Ethernet to DH+ Adapter

User Manual 5

14. Click OK button to close Local Area Connection properties window

IMPORTANT: If your ANC-100e IP address/mask has been already configured with different values, it
will be necessary to adjust the computers Network adapters IP settings to match the IP settings of
the device. Or reset the device to factory defaults.

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 6

Using ANC-100e
Connections
To connect ANC-100e device to your existing DH+ network or directly to another DH+ device, please
use one of the connectors included with the product.
1. Connect the DH+ cable to the ANC-100e. The polarity of blue and clear cables does not
matter
2. Connect ANC-100e to the Ethernet network or Ethernet port on the computer
3. Power on the device using an 24 VDC power adapter
4. The Ethernet light should blink intermittently for a moment
5. The DH+ light will blink every 3 seconds indicating that the device is connected and
associated to a DH+ network
Due to ANC-100e unique DH+ Polarity Detection feature, the way the individual conductors (blue/clear)
of the DH+ cable are connected does not matter, since upon startup, ANC-100e will AutoDetect and
configure itself to use the correct polarity for successful communication regarding of the conductor
cables connection.

LED Diagnostics
ANC-100e is equipped with three LEDs used for visual status and diagnostic display.
The Ethernet LED indicates the data exchange between the ANC-100e and any device in the Ethernet
network. When the device sends/receives a packet, this LED blinks indicating packet exchange.
The DH+ LED indicates the current status of the DH+ network:

LED steady red indicates that the device is not currently associated with a DH+ network.
LED steady green indicates that the device is associated with the DH+ network
LED green and blinks red fast without any particular pattern indicates that the device is
associated with the DH+ network and there is ongoing communication taking place with other
nodes on the network.

The Diag LED indicates special status of the device

Accessing ANC-100e User Interface


IMPORTANT: Before proceeding, make sure that you have configured the Network adapter correctly.
Also make sure the unit is powered on and connected to your computer or Ethernet network.
In case the previously configured IP settings were forgotten or lost and connection to the device
cannot be established anymore, please perform the factory reset described in chapter Reset to
Default Factory Settings of this manual.

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 7

1. Open any web browser and enter the ANC-100e IP address in the address bar. Default IP
address of the device is set to 192.168.137.2
2. Press Enter key

3. Enter the username and password in the corresponding fields. By default, the username is set
to admin and password to password
4. Click OK button.

5. If you entered the correct login credentials, you will be presented with the main configuration
window.

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 8

Configuration and Interface


Device Settings
ANC-100e comes with several unique and innovative features designed to maximize the efficiency of
the device usage under different scenarios. The paragraphs below explain those features in detail.
Automatic DH+ node assignment:
When Auto is selected in the DH+ Node drop down menu, ANC-100e will scan the DH+ network it is
currently connected to, and will assign itself a free, unused node on the network to be used for all
further communication. This unique feature is very convenient when the user needs to communicate
with different DH+ devices on different networks, and allows simple usage without the need to
reconfigure the device using the web interface.
Automatic DH+ Baud Rate detection:
When Auto is selected in the DH+ Baud Rate drop down menu, ANC-100e will scan the DH+
network it is currently connected to, and will automatically detect and configure itself to use the
correct network Baud Rate. This unique feature is very convenient when the user needs to
communicate with different DH+ devices moving between different networks, and allows simple usage
without the need to reconfigure the device by the web interface.
Automatic Polarity detection
This unique feature allows connecting a DH+ cable without worrying about correct cable polarity.

Main Configuration Window


The following information is displayed in the main configuration window:

Fw Version: field displays the current Firmware version of the device


Serial #: field displays the unique serial number of the device
IP address: field displays the current IP address of the device, and allows the user to modify it
is desired
IP Mask: field displays the current network mask of the device, and allows the user to modify
it if desired
DH+ Node: drop down menu displays the current DH+ node settings for the device, and
allows the user to change it if desired. By default, device is set to automatic DH+ node
assignment; please see the description of this feature at the beginning of this chapter
DH+ Baud Rate: drop down menu displays the current DH+ network speed the device is
configured to use, and allows the user to change it if desired.By default, device is set to
automatic DH+ speed detection; please see the description of this feature at the beginning of
this chapter

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 9

1. Select the desired settings on the main configuration page


2. Press the Apply button
3. The device will reboot automatically and new settings will take effect

IMPORTANT: ANC-100e IP address/mask settings must match the Computers Network adapters IP
settings. If you change the ANC-100e or the adapters IP settings, you also need to adjust its
communication partner.

Device Password
IMPORTANT: It is strongly recommended to change the default device password default value to
prevent unauthorized access and reconfiguration of the device.
To change the default web interface login password, please follow the steps below:
1. Type in the current password of the device into the Current Password: field. The default
password is set to password from the factory
2. Type in the desired new password into the New Password: field
3. Type in the same new password into the Confirm Password: field
4. Click on Apply button
5. The device will reboot automatically and the new password will take effect

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 10

Firmware Upgrade
IMPORTANT: Only upgrade the firmware with the firmware image provided by Automation
Networks Inc. support staff and only when it is necessary to do so.
Make sure that the unit is disconnected from the DH+ network by unplugging the cable from the unit
before proceeding with the firmware upgrade.
1. Open any web browser and enter the ANC-100e IP address in the address bar, default IP
address of the device is set to 192.168.137.2
2. Enter the username and password in the corresponding fields, by default, the username is set
to admin and password is set to password
3. Click OK button

4. If you entered the correct login credentials, you will be presented with the main configuration
window

5. Navigate to the Upgrade Firmware tab


6. Click on the Upgrade Button
7. When asked, navigate to the location of the firmware file in your computer

8. Click Open
9. After the file is uploaded, the device will automatically reboot and start up in normal operation
mode using the new firmware

Firmware upgrades will ensure that all the currently configured device settings are preserved and there
is no need to reconfigure the device after the firmware upgrade.

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 11

Statistics
Statistics screen provides a real time statistics data about the health of the device and the network it is
operating on.

Language
Language tab offers English or Spanish language for the web interface. Changing the current web
interface language does not require a device reboot.

Automation Network Inc. 2016

ANC-100e
Ethernet to DH+ Adapter

User Manual 12

Reset to Default Factory Settings:


To reset the device to factory default settings:
1. Power on the device and wait approximately 5 seconds
2. Use a paper clip or similar to press and hold the reset button located under the little hole next
to the DH+ LED indicator light
3. Release the button when all three LEDs light up
4. Device will reboot restoring its factory default settings
IMPORTANT: Factory default settings for the device are:
IP address
Network Mask
DH+ node
DH+ speed
Interface Language
Username
Password

192.168.137.2
255.255.255.0
AUTO
AUTO
English
admin
password

Automation Networks and Solutions LLC


http://automation-networks.com
info@automation-networks.com

Automation Network Inc. 2016