Nalco ACT® Provides Regulatory
Nalco ACT® Provides Regulatory
Nalco ACT® Provides Regulatory
Situation
Performance
By passing a liter of water through a
0.45 filter pad and comparing the
pad to a set of standards, the amount
of iron present in the sample can be
determined. Samples were collected
before starting the Nalco ACT
program and then the improvement
was tracked. After one week using
the Nalco ACT program, we saw
positive results. Before, we saw iron
levels at 500 ppb. Today, the filter pad
results show 10 ppb on the main
condensate system and 25 ppb from
36.3
160
Frequency
Program
200
120
80
14.1
10.0
10.8
10.0
40
3.8
3.6
3.6
3.4
2.4
1.4
0.8
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 More
Corrosion rate (mpy)
Figure 1 Review of over 500 condensate corrosion coupons revealed that almost 50% of
Nalco customers maintain mild steel corrosion rates less than 1 mpy.
Return on Investment
The Nalco ACT program provided
Brewster Dairy with regulatory, safety,
technical and economic benefits not
provided by their prior treatment,
aqueous ammonia. Those benefits
translate into quantifiable Return on
Investment (ROI) for Brewster Dairy.
Eliminating the risk of Lost Time
Accidents was the most important
benefit of the Nalco ACT program.
Because the new treatment is so
inherently safe composed of
materials used in cake frostings and
dairy treats all safety concerns
presented by the ammonia were
eliminated. Estimated savings to
Brewster Dairy: $40,000.
Based on corrosion studies, which
showed corrosion rates in excess of 30