Directional spool valves, direct operated,

with solenoid actuation


RE 23178
Edition: 2013-06
Replaces: 04.09

Type WE

Size 6
Component series 6X
Maximum operating pressure 350 bar [5076 psi]
Maximum flow: 80 l/min [21 US gpm] DC

60 l/min [15.8 US gpm] AC

H7564

Features

Contents

Features1
Ordering code
24
Mating connectors
4
Symbols5
Function, section
6
Technical data
7, 8
Characteristic curves 
9
Performance limits
10 12
Dimensions
13 18
Circuit breakers
19
More information
19

4/3, 4/2 or 3/2 directional design


High-power solenoid
Porting pattern according to DIN 24340 form A
Porting pattern according to ISO 4401-03-02-0-05 and
NFPA T3.5.1 R2-2002 D03
Wet-pin DC or AC solenoids with detachable coil
Solenoid coil can be rotated by 90
The coil can be changed without having to open the
pressure-tight chamber
Electrical connection as individual or central connection
Manual override, optional
Spool position monitoring, optional

RE 23178, edition: 2013-06, Bosch Rexroth AG

2/20

WE | Directional spool valve

Ordering code
01

01

02

03

WE

04

05

6X

06

07

08

09

10

11

12

13

14

15

16

3 main ports

4 main ports

4
WE

02

Directional valve

03

Size 6

04

Symbols e.g. C, E, EA, EB, etc; for the possible version, see page 5

05

Component series 60 to 69 (60 to 69: Unchanged installation and connection dimensions)

06

With spring return

6X
no code

Without spring return

Without spring return with detent

OF

07

High-power wet-pin solenoid with detachable coil

08

Direct voltage 24 V

E
G24
W230

AC voltage 230 V 50/60 Hz

W110
W + voltage

AC voltage 120 V or 110 V 50/60 Hz

G205

Direct voltage 205 V

W110R

DC solenoid with rectifier for AC voltage


(not frequency-related; only available with plug-in connection with cover, see page 17)
Connection to AC voltage mains via control with rectifier (see table below and page 4) 1)
For further ordering codes for other voltages and frequencies, see page 8
09

Without manual override

no code

With concealed manual override (standard)

N9 2)

With manual override

N 2)

With lockable manual override "mushroom button" (small)

N4 2)

With lockable manual override "mushroom button" (big)

N5 2; 3)

With manual override "mushroom button" (big), not lockable

N6 2)

With lockable manual override "nut"

N7 2)

Electrical connection
10

Individual connection
Without mating connector, with connector according to DIN EN 175301-803

K4 4)

Without mating connector, with connector AMP Junior-Timer

C4

4)

Without mating connector, with connector DT 04-2PA (Deutsch plug)

K40

Without mating connector, 4-pole with connector M12x1 according to IEC60947-5-2, integrated interference protection circuit and status LED

K72L 5)

Without mating connector, 4-pole with connector M12x1 according to IEC60947-5-2, integrated interference protection circuit and status LED (no connection pin 1 to pin 2)

K73L 5)

4; 7)

Central connection
DL

Cable entry at the cover, with indicator light

DK6L 6)

Central plug-in connection at the cover, with indicator light (without mating connector); connector according
toDIN EN 175201-804
For further electrical connections, see data sheet 08010

AC voltage mains
(admissible voltage tolerance 10%)

Nominal voltage of the DC solenoid in case of


operation with alternating voltage

Ordering code

110 V - 50/60 Hz

96 V

G96

230 V - 50/60 Hz

205 V

G205

Bosch Rexroth AG, RE 23178, edition: 2013-06

Directional spool valve | WE 3/20

Ordering code
01

02

03

WE

04

05

6X

06

07

08

09

10

11

12

13

14

15

16

Spool position monitoring


11

Without position switch

no code

Inductive position switch type QM


Monitored spool position "a"

QMAG24

Monitored spool position "b"

QMBG24

Monitored rest position

QM0G24

Inductive position switch type QR


QR0G24S

Monitored rest position

QRABG24E

Monitored spool position "a" and "b"


Inductive position switch type QL
Monitored spool position "a"

QLAG24

Monitored spool position "b"

QLBG24

Inductive proximity sensor type QS


Monitored spool position "a"

QSAG24W

Monitored spool position "b"

QSBG24W
QS0G24W

Monitored spool position "0"

QS0AG24W

Monitored spool position "0" and "a"


Monitored spool position "0" and "b"

QS0BG24W

Monitored spool position "a" and "b"

QSABG24W

For more information, see data sheet 24830


12

Without throttle insert

no code

With throttle insert see table:


Port

Throttle in mm [inch]
0.8 [0.031]

1.0 [0.039]

= B08

= B10

1.2 [0.047]
= B12

= H08

= H10

= H12

= R08

= R10

= R12

A and B

= N08

= N10

= N12

= X08

= X10

= X12

Use with flows which exceed the performance limit of the valve (see page 6).
Clamping length
13

no code

42 mm [1.65 inch] (standard)

22 mm [0.87 inch]
Seal material
14

NBR seals

no code

FKM seals

Attention: Observe compatibility of seals with hydraulic fluid used! (Other seals upon request)
15

Without locating hole


With locating hole
With locating hole and locking pin ISO 8752-3x8-St

16

no code
/60 8)
/62

Further details in the plain text

Explanation of the footnotes see page 4.

Preferred types and standard units are contained in


the EPS (standard price list).

RE 23178, edition: 2013-06, Bosch Rexroth AG

4/20

WE | Directional spool valve

Ordering code
1)

Only for version "individual connection"

7)

2)

The manual override cannot be allocated a safety function. The


manual override units may only be used up to a tank pressure
of50 bar.

8)

3)

With tank pressures above 50 bar, it cannot be guaranteed that


the valve remains in the position switched by the
manualoverrideN5.

4)

Mating connectors, separate order, see below and data


sheet08006

5)

Only version "G24", see data sheet 08010

6)

Mating connector, separate order, material no. R900005538

Only possible in connection with the symbols G, J, D and E as


well a reduced performance limit.
Locking pin ISO 8752-3x8-St, material no. R900005694
(separateorder)

Mating connectors according to DIN EN 175301-803

For details and more mating


connectors, see data
sheet08006

Valve side

Material number

1/2" NPT
(Pg 16)

With
rectifier
12 240 V

With
indicator light and
Zener diode suppression circuit
24 V

Color

Without
circuitry

Gray

R901017010

Black

R901017011

a/b

Black

R901017022

R901017029

R901017025

R901017026

Red/
brown

R900004823

Black

R900011039

a/b

Black

R900057453

R900057455

R900842566

Port
M16 x 1.5

With
indicator light
12 240 V

With
indicator light and
rectifier
12 240 V

Bosch Rexroth AG, RE 23178, edition: 2013-06

Directional spool valve | WE 5/20

Symbols

 

 

 


 

 

 

 

 

 



 


 
 

 

 

 

 

 

 

 


 

 

 















 

 

 



 

 

 

 











 





1)

Example:
Symbol E with spool position "a", ordering code ..EA..

2)

Symbol E1-: P A/B pre-opening,


Caution in conjunction with differential cylinders due to
pressure intensification!

Notices!
Representation according to DIN ISO 1219-1.
Hydraulic interim positions are shown by dashes.





RE 23178, edition: 2013-06, Bosch Rexroth AG

6/20

WE | Directional spool valve

Function, section
Directional valves of type WE are solenoid operated directional spool valves. They control the start, stop and direction of a flow.
The directional valves basically consist of the housing (1),
one or two electronic solenoids (2), the control spool (3),
and one or two return springs (4).
In the de-energized condition, the control spool (3) is held
in the central position or in the initial position by the
return springs (4) (except for impulse spools). The control
spool (3) is actuated by wet-pin electronic solenoids (2).
To ensure proper functioning, care must be taken that
the pressure chamber of the electronic solenoid is filled
with oil.
The force of the electronic solenoid (2) acts via the
plunger (5) on the control spool (3) and pushes the latter
from its rest position to the required end position. This
enables the necessary direction of flow from P to A and
Bto T or P to B and A to T.
When the electronic solenoid (2) is de-energized, the
return spring (4) pushes the control spool (3) back to its
rest position.
An optional manual override (6) allows the control
spool(3) to be moved without solenoid energization.

Without spring return "O" (only possible with symbols A,


C and D)
This version is a directional valve with 2 spool positions
and 2 electronic solenoids without detent. The valve
without spring return at the control spool (3) has no
defined basic position in the de-energized condition.
Without spring return with "OF" detent (only possible
with symbols A, C and D)
This version is a directional valve with 2 spool positions
and 2 electronic solenoids with detent. The detents are
used to fix the control spool (3) in the relevant spool
position. During operation, continuous application of
current to the electronic solenoid can thus be omitted
which contributes to energy-efficient operation.
Notices!
Pressure peaks in the tank line to two or several valves
can result in unintended control spool movements in
the case of valves with detent! We therefore recommend that separate return lines be provided or a check
valve installed in the tank line.
Due to the design principle, internal leakage is inherent
to the valves, which may increase over the life cycle.







Type 4WE 6 E6X/...E...



 


Throttle insert
The use of the throttle insert is required when, due to
prevailing operating conditions, flows occur during the
switching processes which exceed the performance limit
of the valve.

Bosch Rexroth AG, RE 23178, edition: 2013-06

Directional spool valve | WE 7/20

Technical data
(for applications outside these parameters, please consult us!)
general
Weight

Valve with one solenoid

kg [lbs] 1.45 [3.2]

Valve with two solenoids

kg [lbs] 1.95 [4.3]

Installation position

Any

Ambient temperature range

C [F] 30 +50 [22 +122] (NBR seals)


20 +50 [4 +122] (FKM seals)
Years 150 (for further details see data sheet 08012)

MTTFd values according to EN ISO 13849


hydraulic
Maximum operating pressure

Ports A, B, P

bar [psi] 350 [5076]

Port T

bar [psi] 210 [3050] (DC); 160 [2320] (AC)


With symbols A and B, port T must be used as leakage oil connection.

Maximum flow
Flow cross-section
(spool position 0)

l/min [US gpm] 80 [21] (DC); 60 [15.8] (AC)


Symbol Q

mm2 Approx. 6% of nominal cross-section

Symbol W

mm2 Approx. 3% of nominal cross-section

Hydraulic fluid

See table below

Hydraulic fluid temperature range

C [F] 30 +80 [22 +176] (NBR seals)


15 +80 [4 +176] (FKM seals)
mm2/s [SUS] 2.8 500 [35 2320]

Viscosity range

Maximum admissible degree of contamination of the hydraulic fluid cleanliness class according to ISO 4406 (c)

Class 20/18/15

1)

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM

DIN 51524

HETG

NBR, FKM

VDMA24568

HEES

FKM

soluble in water

HEPG

FKM

VDMA24568

water-free

HFDU, HFDR

FKM

ISO 12922

containing water

HFC (Fuchs Hydrotherm 46M,


Petrofer Ultra Safe 620)

NBR

ISO 12922

Bio-degradable

Flame-resistant

insoluble in water

Important information on hydraulic fluids!


For more information and data on the use of other hydraulic
fluids, refer to data sheet 90220 or contact us!
There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals,etc.)!
The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.

1)

The cleanliness classes specified for the components must be


adhered to in hydraulic systems. Effective filtration prevents faults
and at the same time increases the life cycle of the components.

For maintenance requirements of the hydraulic fluid and contamination limit values, see data sheet 07300.

For the selection of the filters, see www.boschrexroth.com/filter.

Flame-resistant containing water:


Maximum pressure difference per control edge 50 bar
Pressure pre-loading at the tank port >20% of the pressure
differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP
50 to 100%
Bio-degradable: When using bio-degradable hydraulic fluids that
are simultaneously zinc-solving, zinc may accumulate in the fluid
(per pole tube 700mg zinc).

RE 23178, edition: 2013-06, Bosch Rexroth AG

8/20

WE | Directional spool valve

Technical data
(for applications outside these parameters, please consult us!)
electric
Voltage type
Available voltages 2)
(For ordering codes for AC voltage solenoids, see below)

Direct voltage

Alternating voltage 50/60 Hz

12, 24, 96, 205

110, 230

Voltage tolerance (nominal voltage)

% 10

Power consumption

30

Holding power

VA

50

Switch-on power

VA

220

Duty cycle

% 100

Switching time according ON


to ISO 6403 3)
OFF
Maximum switching frequency
Maximum surface temperature of the coil
Protection class according to DIN EN 60529

ms

25 45

10 20

ms

10 25

15 40

1/h
4)

C [F]

With connector "K4", "K72L", "K73L"

15000

7200

120 [248]

180 [356]

IP 65 (with mating connector mounted and locked)

With connector "C4"

IP 66A (with mating connector mounted and locked)

With connector "K40"

IP 69K (with mating connector mounted and locked)

2)

Special voltages available upon request

3)

The switching times were determined at a hydraulic fluid temperature of 40 C [104 F] and a viscosity of 46cSt. Deviating
hydraulic fluid temperatures can result in different switching
times! Switching times change depending on operating time and
application conditions.

4)

Due to the temperatures occurring at the surfaces of the solenoid


coils, the standards ISO13732-1 and ISO 4413 need to be
adhered to!
The specified surface temperature in AC solenoids is valid for the
faultless operation. In case of error (e.g. blocking of the control
spool), the surface temperature may rise to above 180 C [356 F].
Thus, the system must be checked for possible dangers considering the flash point (see page 7).
As fuse protection, circuit breakers (see table on page 19)
must be used, unless the creation of an ignitable atmosphere can
be excluded in a different way. Thus, the surface temperature can
in case of error be limited to maximally 220 C [428 F].
The tripping current must lie within a time interval of 0.6 s
with8to 10 times the nominal power supply. (tripping characteristics"K").
The necessary non-tripping current of the fuse must not fall
below the value I1 (see table on page 19). The maximum
tripping current of the fuse must not exceed the value I2
(seetable on page 19).
The temperature dependence of the tripping behavior of the
circuit breakers has to be considered according to the manufacturer's specifications.

Bosch Rexroth AG, RE 23178, edition: 2013-06

Notices!
The actuation of the manual override is only possible up to
a tank pressure of approx. 50 bar [725 psi]. Avoid damage to
the bore of the manual override! (Special tool for the
operation, separate order, material no. R900024943).
When the manual override is blocked, actuation of the
opposite solenoid must be ruled out!
The simultaneous actuation of 2 solenoids of one valve
must be ruled out!

Notice!
AC solenoids can be used for 2 or 3 mains; e.g. solenoid
typeW110 for:
110 V, 50 Hz; 110 V, 60 Hz; 120V, 60 Hz
Ordering code

Mains

W110

110 V, 50 Hz
110 V, 60 Hz
120 V, 60 Hz

W230

230 V, 50 Hz
230 V, 60 Hz

When establishing the electrical connection, the protective


earthing conductor (PE ) has to be connected correctly.

Directional spool valve | WE 9/20

Characteristic curves
(measured with HLP46,

oil

= 40 5 C [104 9 F])

Pressure differential in bar [psi]

p-qV characteristic curves












 

  

Symbol



































Flow in l/min [US gpm]


7 Symbol "R" in spool position B A










Direction of flow
P A

P B

A T

B T

A; B

D; Y

J; Q

8 Symbol "G" and "T" in central position P T


9 Symbol "H" in central position P T

RE 23178, edition: 2013-06, Bosch Rexroth AG

10/20

WE | Directional spool valve

Performance limits
(measured with HLP46,

oil

= 40 5 C [104 9 F])
with only one direction of flow (e.g. from P to A while
port B is blocked).
In such cases of application, please consult us!
The performance limit was determined when the solenoids were at operating temperature, at 10% undervoltage and without tank preloading.

Notice!
The specified performance limits are valid for operation
with two directions of flow (e.g. from P to A and simultaneous return flow from B to T).
Due to the flow forces acting within the valves, the
admissible performance limit may be considerably lower

Operating pressure
inbar [psi]



















DC solenoid
Characteristic
curve

Symbol

A; B1)






















 



 

Flow in l/min [US gpm]

Solenoid voltage (DC solenoid)


12; 24; 48; 96; 125; 205 V
(other voltages, see page 11)

Bosch Rexroth AG, RE 23178, edition: 2013-06









A; B

F; P

G; H; T

A/O; A/OF; L; U

C; D; Y

10

E; E12); R3); C/O; C/OF; D/O;


D/OF; Q; W

1) With
2) P

manual override

A/B pre-opening

3) Return

flow from actuator to tank

Directional spool valve | WE 11/20

Performance limits
(measured with HLP46,

oil

= 40 5 C [104 9 F])

See notice on page 10.

Operating pressure
inbar [psi]


















































    

Flow in l/min [US gpm]



Solenoid voltage (DC solenoid)


110; 180 V

Operating pressure
inbar [psi]







































A; B

F; P

J; L; U

D; C

10

C/O; C/OF; D/O; D/OF;


E; E1; R, Q; W

11

A/O; A/OF

DC solenoid

Symbol






DC solenoid
Characteristic
curve












    

Flow in l/min [US gpm]




Characteristic
curve

Symbol

A; B

F; P

J; L; U

A/O; A/OF

10

D; C

Solenoid voltage (DC solenoid)

11

42; 80; 220 V

12

C/O; C/OF; D/O; D/OF;


E1; R, Q; W

RE 23178, edition: 2013-06, Bosch Rexroth AG

WE | Directional spool valve

12/20

Performance limits
(measured with HLP46,

oil

= 40 5 C [104 9 F])

See notice on page 10.

Operating pressure
inbar [psi]













Characteristic
curve

Symbol

11

A; B1)

























AC solenoid 50 Hz





















1) With

Solenoid voltage (AC solenoid)


110 V; 50 Hz
120 V; 60 Hz

W230

230 V; 50 Hz

13

A; B

14

F; P

15

G; T

16

17

A/O; A/OF; C/O; C/OF; D/O; D/OF;


E; E12); J; L; M; Q; R3); U; W

18

C; D; Y

   

Flow in l/min [US gpm]

W110

12

2) P

manual override

A/B pre-opening

3) Return

flow from actuator to tank

(other voltages upon request)

Operating pressure
inbar [psi]




















AC solenoid 60 Hz



Characteristic
curve

Symbol

19

A; B1)






























Solenoid voltage (AC solenoid)


110 V; 60 Hz

W230

230 V; 60 Hz

(other voltages upon request)

Bosch Rexroth AG, RE 23178, edition: 2013-06



   

Flow in l/min [US gpm]

W110



1) With
2) P

20

21

A; B

22

F; P

23

G; T

24

J; L; U

25

A/O; A/OF; Q; W

26

C; D; Y

27

28

C/O; C/OF; D/O; D/OF; E; E12); M; R3)

manual override

A/B pre-opening

3) Return

flow from actuator to tank

Directional spool valve | WE 13/20



Dimensions: Valve with DC solenoid Individual connection


(dimensions in mm [inch])







 










 







 

 










 
 

 





 



 

 



 



 

 



 






 



 







 

 




 

 

Dimensions for manual overrides see page 15.


Item explanations, valve mounting screws and subplates
see page 18.

0,01/100

[0.0004/4.0]

Rzmax 4
Required surface quality of
the valve contact surface

RE 23178, edition: 2013-06, Bosch Rexroth AG

14/20

WE | Directional spool valve

Dimensions: Valve with DC solenoid Central connection


(dimensions in mm [inch])








 

 












 


 




 









 
 

 

 



 


 



 







 

0,01/100

[0.0004/4.0]

Rzmax 4
Required surface quality of
the valve contact surface










 



 

 

Terminal assignment with central connection:


1 solenoid:
Always connect the solenoid to terminals 1 and 2,
the protective earthing connector to terminal
PE
2 solenoids:
Always connect solenoid "a" to terminals 1 and 2,
solenoid "b" to terminals 3 and 4,
the protective earthing conductor to terminal
PE

Dimensions for manual overrides see page 15.


Item explanations, valve mounting screws and subplates
see page 18.

Bosch Rexroth AG, RE 23178, edition: 2013-06

Directional spool valve | WE 15/20

Dimensions: Valve with DC solenoid Manual overrides


(dimensions in mm [inch])








 
 




 
 




 

 




 

 

 

Item explanations, valve mounting screws and subplates


see page 18.

 

0,01/100

[0.0004/4.0]

Rzmax 4
Required surface quality of
the valve contact surface

RE 23178, edition: 2013-06, Bosch Rexroth AG

WE | Directional spool valve

16/20





 










 

  
















0,01/100

[0.0004/4.0]

Rzmax 4
Required surface quality of
the valve contact surface

Item explanations, valve mounting screws and subplates


see page 18.

Bosch Rexroth AG, RE 23178, edition: 2013-06

 

 
 


 



 





 





 
 



 




 





 



 

 



 











Dimensions: Valve with AC solenoid Individual connection


(dimensions in mm [inch])

Directional spool valve | WE 17/20

Dimensions: Valve with AC solenoid Central connection


(dimensions in mm [inch])





  


 

 


 



 


 




 


 





 

 




 










 









 



 



   







 

0,01/100

[0.0004/4.0]

Rzmax 4
Required surface quality of
the valve contact surface

 



 

 

Terminal assignment with central connection:


1 solenoid:
Always connect the solenoid to terminals 1 and 2,
the protective earthing connector to terminal
PE
2 solenoids:
Always connect solenoid "a" to terminals 1 and 2,
solenoid "b" to terminals 3 and 4,
the protective earthing to terminal
PE

Item explanations, valve mounting screws and subplates


see page 18.

RE 23178, edition: 2013-06, Bosch Rexroth AG

18/20

WE | Directional spool valve

Dimensions
1.1 Solenoid "a"
1.2 Solenoid "b"
2 Dimension for solenoid with concealed manual override "N9"
(standard)
3 Dimension for solenoid with manual override "N"
4 Dimension for solenoid without manual override
5 Dimension for solenoid with manual override "N7"
6 Dimension for solenoid with manual override "N5" and "N6"
6.1 Manual override "N5"
6.2 Manual override "N6"
7.1 Mating connector without circuitry for connector "K4"
(separate order, see page 4 and data sheet08006)
7.2 Mating connector (AMP Junior Timer) with connector "C4"
(separate order, see data sheet 08006)
7.3 Mating connector DT 04-2PA (Deutsch plug) with connector "K40"
(separate order, see data sheet 08006)
7.4 Mating connector angled with M12x1 plug-in connection
with status LED "K72L" (separate order, see data
sheet08006)
8 Mating connector with circuitry for connector "K4"
(separate order, see page 4 and data sheet 08006)
9 Cable gland Pg 16 [1/2" NPT] "DL"

Subplates according to data sheet 45052


(separate order)
(without locating hole)
G 341/01 (G1/4)

G 342/01 (G3/8)

G 502/01 (G1/2)
(with locating hole)
G 341/60 (G1/4)

G 342/60 (G3/8)

G 502/60 (G1/2)

G 341/12 (SAE-6) 1)

G 342/12 (SAE-8) 1)

G 502/12 (SAE-10) 1)
1) Upon request
Valve mounting screws (separate order)
Clamping length 42 mm:
4 metric hexagon socket head cap screws
ISO 4762 - M5 x 50 - 10.9-flZn-240h-L
(friction coefficient total = 0.09 to 0.14);
tightening torque MA = 7 Nm [5.2 ft-lbs] 10%,
material no. R913000064

or
4 hexagon socket head cap screws
ISO 4762 - M5 x 50 - 10.9 2)
(friction coefficient total = 0.12 to 0.17);
tightening torque MA = 8.1 Nm [6 ft-lbs] 10%

10 Central plug-in connection "DKL"

4 hexagon socket head cap screws UNC 10-24 UNC x 2" ASTM-A574
(friction coefficient total = 0.19 bis 0.24);
tightening torque MA = 11 Nm [8.2 ft-lbs] 15%,
(friction coefficient total = 0.12 to 0.17);
tightening torque MA = 8 Nm [5.9 ft-lbs] 10%,
material no. R978800693

10.1 Angled socket (red, separate order)


Material no. R900005538)
11 Name plate
12 Identical seal rings for ports A, B, P, T
Notice! The ports are clearly determined according to
their tasks and must not be arbitrarily interchanged
orclosed.
13 Plug screw for valves with one solenoid
14 Space required to remove the mating connector/
angledsocket
15 Space required to remove the coil
16 Mounting nut, tightening torque MA = 4+1Nm [2.95+ 0.74ft-lbs]
17 Porting pattern according to DIN 24340 form A (without
locating hole), or ISO 4401-03-02-0-05 and
NFPA T3.5.1 R2-2002 D03 (with locating hole for locking pin
ISO 8752-3x8-St, material no. R900005694, separate order)

Clamping length 22 mm:


4 metric hexagon socket head cap screws
ISO 4762 - M5 x 30 - 10.9-flZn-240h-L
(friction coefficient total = 0.09 to 0.14);
tightening torque MA = 7 Nm [5.2 ft-lbs] 10%,
material no. R913000316

or
4 hexagon socket head cap screws
ISO 4762 - M5 x 30 - 10.9 2)
(friction coefficient total = 0.12 to 0.17);
tightening torque MA = 8.1 Nm [6 ft-lbs] 10%
4 hexagon socket head cap screws UNC 10-24 UNC x 1 1/4"
(friction coefficient total = 0.19 to 0.24);
tightening torque MA = 11 Nm [8.2 ft-lbs] 15%,
(friction coefficient total = 0.12 to 0.17);
tightening torque MA = 8 Nm [5.9 ft-lbs] 10%,
material no. R978802879

18 Alternative clamping length (): 22 mm [0.87 inch]


19 Cover
Attention!
The valve may only be operated with properly mountedcover.

2)

Bosch Rexroth AG, RE 23178, edition: 2013-06

Not included in the Rexroth delivery range

Directional spool valve | WE 19/20

Circuit breakers with tripping characteristic "K"


according to EN60898-1 (VDE 0641-11), EN60947-2 (VDE 0660-101), IEC60898 and IEC60947-2

Lower rated current


I1 in A

Upper rated current


I2 in A

AC solenoid

Lower rated current


I1 in A

Upper rated current


I2 in A

W24

2.30

3.60

W42

1.45

1.92

W24

1.73

2.40

W42

1.13

W48

1.15

1.92

1.92

W48

1.09

W100

1.92

0.64

0.90

W100

0.58

0.90

W110

0.60

0.90

W110

0.52

0.90

W115

0.52

0.90

W115

0.43

0.90

W127

0.48

0.60

W127

0.37

0.60

W200

0.33

0.60

W200

0.30

0.60

W220

0.31

0.60

W220

0.26

0.36

W230

0.26

0.36

W230

0.20

0.36

W240

0.26

0.36

W240

0.22

0.36

AC solenoid
50 Hz

50 Hz

More information
Subplates

Data sheet 45052

Inductive position switch and proximity sensors (contactless)

Data sheet 24830

Smoothly switching version

Data sheet 23183

Mineral oil-based hydraulic fluids

Data sheet 90220

Reliability characteristics according to EN ISO 13849

Data sheet 08012

General product information on hydraulic products

Data sheet 07008

Installation, commissioning and maintenance of industrial valves

Data sheet 07300

Hydraulic valves for industrial applications

Data sheet 07600-B

Selection of the filters

www.boschrexroth.com/filter

RE 23178, edition: 2013-06, Bosch Rexroth AG

20/20

WE | Directional spool valve

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52/18-0
documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG, RE 23178, edition: 2013-06

This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the user
from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.