Montavimo Technika Armaturos Strypams
Montavimo Technika Armaturos Strypams
Montavimo Technika Armaturos Strypams
Rebar connections
Professional rebar connections
Rebar connections
Rebar connections
BUILDING MATERIALS
APPROVALS
Approved for:
Concrete C12/15 to C50/60,
cracked and non-cracked
ADVANTAGES
APPLICATIONS
FUNCTIONING
FIS V mortar
see page 71
FIS VS mortar
see page 79
123
Chemical fixings
Rebar connections
INSTALLATION WITH FIS V / FIS VS
TECHNICAL DATA
Art.-No.
Approval
Combination
of materials
Total length
Max. xing
thickness
Drill-hole
Fill quantity
Sales unit
DIBt
ETA
[mm]
tfix
[mm]
d0
[ mm]
[scale units]
[pcs]
975
1180
1485
60
60
60
16
20
25
50
81
160
8
8
4
Item
Reinforcement bar welded with threaded part made of stainless stell A4.
124
Chemical fixings
Rebar connections
TECHNICAL DATA
Approval
Item
Art.-No.
DIBt
Contents
Sales unit
ETA
FIS-Rebar case D
505941
505942
[pcs]
ACCESSORIES
Cleaning brush with thread M 8
Item
Colour
Length
[mm]
white
blue
red
yellow
green
black
grey
brown
-
420
-
Art.-No.
001490
001491
001492
001493
001494
001495
090063
090071
505061
506254
505062
508791
511961
Sales unit
[pcs]
1
1
1
1
1
1
1
1
1
1
1
1
2
ACCESSORIES
Injection adapter for drill 12 - 25 mm
Extension tube
Item
Colour
Sales unit
[pcs]
white
blue
red
yellow
green
green
10
10
10
10
10
10
Art.-No.
001497
001498
001499
001483
001506
001508
125
Chemical fixings
Rebar connections
ACCESSORIES
Injection adapter for drill 12 - 25 mm
Extension tube
Item
Colour
Sales unit
[pcs]
black
black
grey
grey
brown
brown
-
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Art.-No.
001507
001509
090689
090700
090699
090701
505077
505079
508909
508910
505078
505080
048983
001489
ACCESSORIES
Drilling aid
Item
Sales unit
[pcs]
Art.-No.
090819
ACCESSORIES
SDS-max scrabbeling tool to roughen the connection surface
Item
Fits
Dimensions
[mm]
Sales unit
[pcs]
45 x 240
Art.-No.
Stocker
001253
ACCESSORIES
Fits
Item
126
Art.-No.
511956
511957
511958
511959
511960
Drill diameter 12 - 15 mm
Drill diameter 16 - 19 mm
Drill diameter 20 - 25 mm
Drill diameter 30 - 35 mm
Drill diameter 40 - 45 mm
Sales unit
[pcs]
2
2
2
2
2
LOADS
Injection system FIS V, FIS VS and FIS EM with Rebars from steel type BSt 500 S5)
Design resistant loads and permissible tensile loads1) 6) of a single post-installed Rebar in concrete C20/252).
For the design and planning the complete approval ETA - 09/0089 and ETA - 08/0266 have to be considered.
Rebar
8 mm
10 mm
12 mm
14 mm
16 mm
20 mm
25 mm
28 mm
32 mm
36 mm
40 mm
1)
2)
3)
4)
5)
[mm]
[mm]
[mm]
[kN]
[kN]
378
473
567
662
756
945
1181
1323
-
378
473
567
662
756
945
1181
1323
1512
1701
1890
1800
1800
1800
1800
1800
1800
2000
2000
2000
2000
2000
21,9
34,1
49,2
66,9
87,4
136,6
213,4
267,7
349,7
442,6
546,4
15,6
24,4
35,1
47,8
62,4
97,6
152,4
191,2
249,8
316,1
390,3
The partial safety factors for material resistance as regulated in the European Standard EN 19921-1 as well as a partial safety factor for load actions of JL = 1,4 are considered.
The ETA-approvals for FIS V and FIS EM allow post-installed rebar connections in concrete C12/15
up to C50/60. When using another concrete strength class the given basic anchorage length will
change.
When using the full steel capacity.
Basic anchorage length" according EN 1992-1-1, chapter 8.4.3 for concrete strength class
C20/25 for "good bond conditions"
Rebars with a characteristic yield strength fyk = 400 - 600 N/mm according EN 1992-1-1
6)
7)
Max. permissible
embedment depth
max lv
Chemical fixings
Rebar connections
AnnexC,Table C.1 and C.2N are permitted. When using an other steel quality the given basic
anchorage length as well as the steel capacity (see foot note 3) will change.
Fixations with post-installed rebars with FIS V and FIS EM are permitted in dry and wet concrete
for temperatures in the substrate up to +50C (resp. short term up to 80C) and best possible
drillhole cleaning according approval.
For determination of the installation measures (minimum concrete cover, spacings e.g.) as well
as an eventually required transverse reinforcement see EN 1992-1-1 and the general instruction
rules of the approvals.
LOADS
Injection system FIS V, FIS VS and FIS EM with Rebar anchor FRA5)
Highest permissible tensile loads1) 6) for a single Rebar anchor in concrete C20/252).
For the design and planning the complete approvals ETA - 09/0089 and ETA - 08/0266 have to be considered.
Type
2)
3)
4)
Basic
anchorage length4)
lb,rqd
Max. effective
embedment depth
max lv
Max.
embedment depth
max le,ges
[mm]
[mm]
[mm]
[Nm]
[kN]
[kN]
567
756
945
800
1000
1300
900
1100
1400
50,0
100,0
150,0
49,2
87,4
136,6
35,1
62,4
97,6
The partial safety factors for material resistance as regulated in the European Standard EN 19921-1 as well as a partial safety factor for load actions of JL = 1,4 are considered.
The ETA-approvals for FIS V and FIS EM allow post-installed rebar connections in concrete C12/15
up to C50/60. When using another concrete strength class the given basic anchorage length will
change.
When using the full steel capacity.
Basic anchorage length according EN 1992-1-1, chapter 8.4.3 for concrete strength class C20/25
for good bond conditions
5)
6)
7)
Reinforcement bar BSt 500 S according EN 1992-1-1 Annex C,Table C.1 and C.2N.
Fixations with post-installed Rebars anchors FRA with FIS V and FIS EM are permitted in dry and
wet concrete for temperatures in the substrate up to +50C (resp. short term up to 80C) and
best possible drillhole cleaning according approval.
For determination of the installation measures (minimum concrete cover, spacings e.g.) as well
as an eventually required transverse reinforcement see EN 1992-1-1 and the general instruction
rules of the approvals.
127