You are on page 1of 4

BP SX 80

80-Watt
Multicrystalline Photovoltaic Modules
BP Solars SX series provides cost-effective photovoltaic power for
general use, operating DC loads directly or, in an inverter-equipped
system, AC loads. With 80 watts of nominal maximum power, the BP SX 80
is well-suited to traditional applications of photovoltaics such as telecommunications, remote villages and clinics, pumping, and land-based aids
to navigation. Its 36 series-connected cells charge batteries efficiently in
virtually any climate.

Proven Materials
and Construction
BP Solars quarter-century of field
experience shows in every aspect
of this modules construction and
materials:
Frame strength exceeds requirements of certifying agencies;
36 multicrystalline silicon solar
cells configured as two 18-cell
series strings with two bypass
diodes installed;
Cells are laminated between
sheets of ethylene vinyl acetate
(EVA) and high-transmissivity
low-iron 3 mm tempered glass.

Clear Anodized
Universal Frame
Limited Warranties
Power output for 20 years;
Freedom from defects in
materials and workmanship
for 1 year.
See our website or your local
representative for full terms of
these warranties.

High-Capacity Versatile
Junction Box
The junction box is raintight (IP54
rated) and accepts PG13.5 or 1/2
nominal conduit or cable fittings. Its
volume (411cc, 25 cubic inches) and
6-terminal connection block enable
most system array connections (putting modules in series or parallel) to
be made right in the junction box.
Options include:
oversize terminal block which
accepts conductors up to 25mm2
(AWG #4); standard terminals
accept up to 6mm2 (AWG #10);

SolarstateTM charge regulator.


Shipped in 12V configuration, modules may easily be switched to 6V
configuration by moving leads in
the junction box. Six-volt modules
are intended to support 6V loads,
and are not recommended as series
elements in higher voltage arrays.

Quality and Safety


Manufactured in ISO 9001certified factories;
Listed by Underwriters
Laboratories for electrical and fire
safety (Class C fire rating);
Certified by TV Rheinland as
Class II equipment for use in
systems with voltage up to
1000VDC;
Approved by Factory Mutual
Research for application in NEC
Class 1, Division 2, Groups C &
D hazardous locations;
Compliant with the requirements
of IEC 61215, including:
repetitive cycling between
-40C and 85C at 85% relative
humidity;
simulated impact of 25 mm
(one-inch) hail at terminal
velocity;
a damp heat test, consisting
of 1000 hours of exposure to
85C and 85% relative humidity;
a hot-spot test, which determines a modules ability to
tolerate localized shadowing
(which can cause reversebiased operation and localized
heating);
static loading, front and back,
of 2400 pascals (50 psf); front
loading (e.g. snow) of 5400
pascals (113 psf).

BP SX 80
TV

BP Solar 2001 01-4005-1 2/01

2.54 [0.100] max.


screw head
projection, typ.

502 [19.75]

11.2 [0.44]

Front view
X

2.3 [0.09]

50 [1.98]
26.9 [1.06]

Section X-X

1456 [57.31]

1461 [57.51]
(includes screwheads)

965 [38.00]
Grounding hole,
2 places.

Back view

Junction box
9.6 [0.38] X 12.7 [0.50] dia.
mtg. holes, typ.

17 [0.69]

245 [9.66]

467 [18.37]

BP SX 75U, 80U, 85U

Mechanical Characteristics
Weight
BP SX 80

9.5 kg (20.9 pounds)

Dimensions
Unbracketed dimensions are
in milimeters. Bracketed
dimensions are in inches.
Overall tolerances 3mm (1/8")

Grounding Detail

17 [0.69] typ.

Typical Electrical Specifications(1)

BP SX 75

BP SX 80

75W

80W

85W

16.5W

16.8V

17.1V

Current at Pmax (lmp)


Warranted minimum Pmax

4.54A

4.75A

4.97A

70W

75W

80W

Short-circuit current (Isc)


Open-circuit voltage (Voc)

4.97A

5.17A

5.3A

20.7V

21.0V

21.3V

Maximum Power (Pmax)


Voltage at Pmax (Vmp)

Temperature coefficient of Isc


Temperature coefficient of Voc

(0.0650.015)%/C

Temperature coefficient of Power

-(0.50.05)%/C

NOCT

BP SX 85

-(8010)mV/C
472C

Maximum system voltage

600V

Notes
1. These data represent the performance of typical modules in 12V
configuration as measured at their output terminals, and do not
include the effect of such additional equipment as diodes or cables.
The data are based on measurements made in accordance with ASTM
E1036-85 corrected to SRC (Standard Reporting Conditions, also
known as STC or Standard Test Conditions), which are:
illumination of 1 kW/m2 (1 sun) at spectral distribution of AM 1.5
(ASTM E892-87 global spectral irradiance);
cell temperature of 25C.
2. During the stabilization process which occurs during the first few
months of deployment, module power may decrease approximately
3% from typical Pmax.
3. The cells in an illuminated module operate hotter than the ambient
temperature. NOCT (Nominal Operating Cell Temperature) is an indicator of this temperature differential, and is the cell temperature under
Standard Operating Conditions: ambient temperature of 20C, solar
irradiation of 0.8 kW/m2, and wind speed of 1 m/s.
4. U.S. NEC rating.

BP SX 80 I-V Curves
6.0

5.0

T=0C
4.0

T=25C
T=50C

Current (A)

T=75C
3.0

2.0

1.0

0
0

10
15
Voltage (V)

20

25

This publication summarizes product specifications and


warranty. For details of construction, performance, and
warranty, see our website www.bpsolar.com or contact
your local representative. Specifications subject to change
without notice.

BP Solar uses recycled and recyclable materials in its operation to the fullest extent.