FluidFlow Designer Handbook

Download as pdf or txt
Download as pdf or txt
You are on page 1of 78

FluidFlow

DESIGNER HANDBOOK
Flite Software 2015

Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd,
Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 |
E: sales@fluidflowinfo.com | www.fluidflowinfo.com

Introduction ................................................................................................................................................... 2

FluidFlow User Interface. ............................................................................................................................... 3

Liquid Flow Modeling ..................................................................................................................................... 4

3.1

Liquid Design Exercise 1 ........................................................................................................................ 4

3.2

Liquid Design Exercise 2 Auto-Sized Pump, Pipes & Control Valve. ................................................. 14

Compressible Flow Modeling. ...................................................................................................................... 27


4.1

Calculation Settings Compressible Flow. .......................................................................................... 27

4.2

Gas System Design Exercise 1. ............................................................................................................ 28

Two-Phase (Liquid-Gas) Flow Modeling. ...................................................................................................... 38


5.1

Calculation Settings Two-Phase Flow. .............................................................................................. 38

5.2

Option 1: Two-Phase Design Exercise 1 (Changing Quality System). .................................................. 39

5.3

Option 2: Two-Phase Design Exercise 2 (Constant Quality System). .................................................. 46

5.4

Option 3: Two-Phase Design Exercise 3 (Changing Quality System). .................................................. 51

Non-Newtonian Non-Settling Slurry Flow.................................................................................................... 54


6.1

Settling Slurry Flow ...................................................................................................................................... 61


7.1

Calculation Settings Settling Slurry Flow. ......................................................................................... 61

7.2

Settling Slurry Design Exercise 1 ......................................................................................................... 62

Auto-Equipment Sizing ................................................................................................................................ 68


8.1

Non-Newtonian Design Exercise 1 ...................................................................................................... 54

Auto-Equipment Sizing Design Exercise 1 ........................................................................................... 68

FluidFlow FAQs............................................................................................................................................ 73

FluidFlow Designer Handbook

Page 1

1 Introduction
FluidFlow is designed to allow the modelling of fluid behaviour within complex piping
systems and accurately predict how the system will work for a given set of boundary
conditions. The software uses a number of well-established models and correlations to
solve the piping systems.
The purpose of this document is to give new users a brief overview of how to develop
models using the software, how to apply different design methodologies and
correlations.
This designer handbook includes a number of design examples to help you begin using
the software. The design exercises are split in accordance with the various FluidFlow
Modules available, i.e. Liquid, Gas, Two-Phase (Liquid-Gas), non-Newtonian & Settling
Slurry flow.
The software includes powerful auto-sizing functionality and to this end, a design
example is included at the end of the document.
FluidFlow is provided with a comprehensive database of fluids, pumps, valves, pipes and
components and also allows you to model non-standard fittings. This therefore means
we can model practically any pipe fitting. Users can also add new fluids and components
to the database, a task which you only need to complete once as the data will be stored
for future modeling projects.
Heat transfer functionality is also included with each Module as standard, i.e. no extra
cost.
There is no limit to the number of nodes you use to build your model, allowing greater
modeling flexibility.
This document also contains a list of FAQs which you are free to peruse at your
convenience.
FluidFlow users have reported that the software has saved approximately 80% of
engineers time vs excel when solving systems and 40% when compared to other
software applications. The highly intuitive user interface combined with database of
fluids and components has helped engineers get to grips with the program efficiently.
This combined with world class technical product support helps you model your specific
systems in an instant.
If you have a specific design application and wish to use an intuitive user friendly
program to speed up your design process, contact us at: support@fluidflowinfo.com.
Testimonial:
FluidFlow is fast, easy to use, accurate and a reliable package. The software drastically
cuts design time - these benefits apply not only to the designer but also to the peer
review team. During operation of the built systems, the agreement between running
plant pressure readings against design data was highly accurate. That bought my full
trust in the package.
Mat Landowski, Lead Process Engineer

FluidFlow Designer Handbook

Page 2

2 FluidFlow User Interface.


FluidFlow is based on a single user interface (Figure 2.1.1) which is used for all Modules,
i.e. liquids, gases, two-phase flow etc. This permits greater modeling freedom and
eliminates the need to repeatedly re-build models it you wish to calculate as a liquid,
gas, two-phase system etc.
The user interface is quite simple which promotes fast model building. Models are
developed on the flowsheet using the components available to us on the Component
Palette. We can then quickly edit default design data for each node using the Input tab
of the Data Palette. Once we calculate a model, the results can be viewed on the Results
tab of the Data Palette.
The Status Bar at the bottom of the flowsheet allows us to quickly view the calculation
settings assigned to the model.

Component Palette
Flowsheet Toolbar

Flowsheet

Data Palette

Status Bar

Figure 2.1.1: User Interface.

We have developed this user-interface based on feedback from engineers and designers
over the years and our users enjoy the simplicity of the user interface as it permits fast
and effective model development.

FluidFlow Designer Handbook

Page 3

3 Liquid Flow Modeling


3.1

Liquid Design Exercise 1

Calculate the pressure loss, flow rate and heat transfer for a 12.0 M long 4 inch schedule
40 steel pipe (uninsulated) transporting water at 82oC. The pipe inlet pressure shall be
1.5 barg with an outlet pressure of 1.0 bar g. The pipe shall include 6 bends and a single
butterfly isolation valve.
Step 1: The first step is to consider the boundary nodes to use for the system. Since we
know the inlet and outlet pressure, we can use the Known or Assigned Pressure node
available from the Boundaries tab on the Component Palette (Fig 3.1.1).

Figure 3.1.1: Known Pressure Node.

Place two of these nodes (inlet & outlet) on the flowsheet by left mouse-clicking on the
icon on the Component Palette. To place the node on the flowsheet we need to left
mouse-click in the desired location (Fig 3.1.2).

Figure 3.1.2: Known Pressure Nodes.

This represents our pipe boundaries. We can now connect the boundaries by selecting
the desired pipe material from the Component Palette. In this design case, we know the
pipe is schedule 40 steel pipe. We therefore need to select the Steel Pipe or Duct icon
from the Component Palette (Fig 3.1.3).

Figure 3.1.3: Steel Pipe of Duct Icon.

To connect the boundaries, left mouse-click directly over the inlet boundary node (node
1) and again, left mouse-click directly over the outlet boundary node (node 2). Note,
when you position the mouse selector above the boundary node on the flowsheet\, you
will see the selector change to a green tick symbol. This indicates that the software is
ready to connect our new node.

FluidFlow Designer Handbook

Page 4

Figure 3.1.4: Base Model.

As this stage, we will notice that the software automatically assigns a unique User
Number (reference Number) to each node placed on the flowsheet. All boundaries and
fittings have positive User Numbers whereas all pipe have negative User Numbers. In
Figure 3.1.4 we can see that the inlet and outlet boundaries are assigned with User
Number 1 & 2 respectively and the single pipe is assigned with the User Number -1.
The automatic assignment of User Numbers helps us differentiate each of the nodes
when we interrogate our systems post calculation. This will become more apparent
later.
To complete the model connectivity, we need to include a bend and butterfly valve node.
Select the bend icon from the Junctions tab and insert near the end of the pipeline. Now
select the butterfly valve icon from the Valves tab and insert near the beginning of the
pipeline. The final model should appear as shown in Figure 3.1.5.

Figure 3.1.5: Completed Model.

You will note how the software automatically updates the node User Numbers during the
model development.
Step 2: The next step is to edit the default data for each of the nodes placed on the
flowsheet. Lets begin with the boundaries. We know the intended pressure units are in
barg for both the inlet and outlet boundary. We can edit multiple nodes at once which
will help speed up model development.
Left mouse-click on the inlet boundary (node 1) and whilst holding the SHIFT key, left
mouse-click on the outlet boundary (node 2). You should now see both nodes
highlighted on the flowsheet. We can now edit the data-entry for both nodes at once
from the Input Inspector on the Data Palette (Fig 3.1.6).

FluidFlow Designer Handbook

Page 5

Figure 3.1.6: Input Inspector.

In this case we need to change the Pressure Unit from the default atm setting to barg.
Left mouse-click on the Pressure Unit field and you will see a down-arrow symbol appear
on the right hand side. Click on this symbol and a drop-down menu will appear showing
the various units you can choose from. Select barg from the list. We have now
successfully changed the pressure units for both nodes.

Figure 3.1.7: Pressure Units.

We can also change the design inlet pressure and fluid temperature by selecting node 1
and changing the pressure to 1.5 barg and the temperature to 82 oC.
Lets now edit the default pipe data. We have a total pipe length of 12.0 M. We are going
to assume three equal segment lengths of 4.0 M each. Once again, we can edit multiple
common nodes. Lets use a different approach.
Select the List tab on the Data Palette and place a check-mark in the field titled Pipes
(Figure 3.1.8). The software will now list all pipes in the flowsheet including their User
Numbers.

Figure 3.1.8: Pipe List.

FluidFlow Designer Handbook

Page 6

You can multi-select the pipes in the flowsheet by selecting the first pipe on the list,
holding the SHIFT key and finally, select the last pipe on the list. You will then see all
pipes marked off on the List and also on the flowsheet.
Click on the Input Inspector and enter a length of 4.0 M for all three pipes. To change
the pipe diameter, click on the field titled Nominal Size and a drop-down menu will
appear. Click on this menu as this will allow us to access the pipes database. From the
list of available pipe sizes, click on 4 inch to view the various pipe classifications for this
diameter. Select Schedule 40 followed by OK to complete this change.
Now change the Heat Loss Model for all three pipes from the Input Inspector from Ignore
Heat Loss/Gain to Do Heat Loss Calculation. A number of additional fields will now
appear. Since the pipe is uninsulated, we need to change the field for Use Insulation
from Yes to No. We can accept the default values for Heat Transfer Coefficient (U Value),
Local Ambient Temperature, Surface Emissivity & Local Wind Speed.
The final step is to complete the data-entry for the fittings. Click on the bend node and
from the Input Inspector, set the Quantity field to 6. We are going to leave all other
parameters as default for this design case.
Now select the butterfly valve on the flowsheet. From the Input Inspector, we can see
that the valve is 100% fully open and the Valve Name is Generic Butterfly Valve Miller
Data. For the purposes of this exercise, we are going to use this valve type. If however
we wished to model an alternative valve from the database, we can select the Valve
Name field, select the drop-down menu and choose the desired valve from the data
base.
Note, this entire system is horizontal and as such, we have left all node elevations as 0
M. If we wish to set changes in system elevations, we would define the elevation values
at all boundaries and fittings using the Input Inspector.
Step 3: Calculate the model using the Calculate button located at the top of the
flowsheet. You may now notice that the three pipes have been highlighted in RED,
indicating we have a warning message associated with each pipe element. If we select
the Messages tab on the Data Palette, we can view all warnings for the model including a
description of each.
Note, warnings are enunciated by the software automatically to help the user eliminate
any unwanted operating conditions and to prompt the user to develop a more efficient
system design. Warnings should always be reviewed and considered by the engineer.
You can evaluate and choose to ignore warnings if you wish.
The three warnings associated with this model are outlined in Figure 3.1.9. Each warning
is displayed together with the User Number of the node which it relates to in brackets. If
you select a warning, the node it relates to is automatically highlighted on the flowsheet.
This interaction helps us quickly troubleshoot our models.

FluidFlow Designer Handbook

Page 7

Figure 3.1.9: Warning Messages.

In this case, we have three high velocity warnings. If we review the Results tab followed
by pipe node -1, we can see all calculated values for this pipe. Figure 3.1.10 provides an
overview of these results.

FluidFlow Designer Handbook

Page 8

- Suggested Economic Pipe .


- Actual I.D. of 4 Sch. 40 Pipe.

The In values
represent the
calculated conditions
at the pipe Inlet.

The Out values


represent the
calculated conditions
at the pipe Outlet.

Figure 3.1.10: Calculated Results.

Warnings are enunciated based on the settings defined in Warnings & Hints. You can
view these set-points by selecting; Options | Warnings & Hints or alternatively, select
the Warnings & Hints icon at the top of the flowsheet.
Warnings & Hints icon:

Since we are modeling a liquid system, we are only interested in the Liquid Limits
(Figure 3.1.11).

FluidFlow Designer Handbook

Page 9

Figure 3.1.11: Warnings & Hints - Liquid Limits.

As we can see in Figure 3.1.10, the actual flowing velocity of the fluid is 4.93 m/s. The
high velocity warning is enunciated since this flowing velocity is higher than the
maximum velocity level set in our warnings (4 m/s See Figure 3.1.11).
We can therefore give some consideration to changing this pipe diameter to develop a
more efficient design. To help us, FluidFlow automatically calculates an Economic
Velocity and associated Exact Economic Size for each pipe in the model. These results
can be viewed on the Results tab (Figure 3.1.10) and are provided as a suggestion in
order to help develop an efficient system design. Note, it is down to the engineers
discretion as to whether or not the actual pipe size needs to be changed to be more in
line with that suggested by the software. Therefore, the results for Economic Velocity
and associated Exact Economic Size are suggested values only and do not have any
effect on the overall operating conditions for the system.
For the purposes of this exercise, we are going to ignore these warnings and continue
with the 4 inch schedule 40 pipework.
Results: We have established that the pressure loss across each element in this system
and that the total pressure loss will be;
Stagnation Pressure at inlet (Node 1):
Stagnation Pressure at outlet (Node 2):

251325 Pa.
201325 Pa.

Pressure Loss: 50000 Pa.


We know this is correct since we had an inlet pressure of 1.5 barg and an outlet pressure
of 1.0 barg which gives us a difference of 0.5 bar g or, 50000 Pa.
The flow rate is calculated as 39.331 kg/s. Note, we can change our units by right
mouse-clicking on the Results tab followed by selecting Results Units from the dropdown menu. Alternatively, you can select F9. This opens a new dialogue as per Figure
3.1.12.

FluidFlow Designer Handbook

Page 10

Figure 3.1.12: Set Result Units Dialogue.

Lets select volumetric flow units of m3/h followed by OK. The result for flow will change
automatically to 145.8 m3/h.
The amount of heat transferred for each pipe can be viewed on the Results tab. Pipe
node -1 as a heat loss of 1.7 kW. If we quickly view the results for the other two pipes
in the model, we can see that they also have a heat loss of 1.7 kW which is what we
would expect since they are all the same length and diameter.
If we wish to reduce this heat loss and consider the effects of adding insulation. Lets
multi-select the pipes on the flowsheet using yet another approach. Select; Edit | Select
| Select Pipes. All pipes will now be marked-off on the flowsheet. From the Input
Inspector, change the field for Use Insulation from No to Yes. We can choose from a
range of insulation materials and thicknesses, in this case, we will accept mineral wool
and the thickness of 25mm.
Based on these changes, we now need to recalculate the model to refresh our results.
Once complete, we can see that the amount of heat loss in each pipe has reduced from
1.7 kW to 0.2 kW.
FluidFlow also plots the system resistance curve for all pipes. You can view this curve
plot by selecting the Chart tab on the Data Palette. Figure 3.1.13 provides an illustration
of the resistance curve for pipe node -1. The duty-point is denoted by the red indicator.

FluidFlow Designer Handbook

Page 11

Figure 3.1.13: System Resistance Curve.

If you wish to plot a hydraulic and energy grade line (HGL/EGL) for the system, you can
generate this plot by selecting the Setup Composite Plot icon from the flowsheet toolbar
to the left of the flowsheet.
Setup Composite Plot icon:

Selecting this option opens a new dialogue as per Figure 3.1.14.

Figure 3.1.14: Setup Composite Plot.

FluidFlow Designer Handbook

Page 12

Click on the tab titled EGL and HGL. We must now choose the starting point for the
plot. In this case, we start the plot at the inlet boundary (node 1) and end it at the main
outlet (node 2). Select Plot when this data-entry is complete and a graph shall appear as
per Figure 3.1.15.

Figure 3.1.15: EGL and HGL Graph Plot.

This graph plot helps us identify any potential trouble-spots in our system. Select Close
to exit the graph.
Note, you can improve the presentation of your model by selecting all pipes and
changing the Draw Thickness and Draw Color from the Input Inspector. We have set the
Draw Thickness to 3 and Draw Color to clRed. We also multi-selected the main inlet and
outlet boundaries (holding the SHIFT key) and from the Input Inspector, changed the
field titled Properties on Flowsheet from Hide to Show. We then selected the field titled
Properties and from the Input list. Placed a check-mark in the box for; Pressure and
Elevation. We then changed the Font to Bold and Size 11.
The model now appears as per Figure 3.1.16.

Figure 3.1.16: EGL and HGL Graph Plot.

FluidFlow Designer Handbook

Page 13

3.2

Liquid Design Exercise 2 Auto-Sized Pump, Pipes & Control Valve.

We are required to build the model as shown in Figure 3.2.1 using schedule 40 steel
pipework and automatically size the pump, pipes and butterfly flow control valve. The
system shall be provided with a single centrifugal pump to transport water at 20 oC
through a network of pipework to two outlets discharging at a pressure of 1.1 barg. The
lower outlet shall be provided with a flow control device to control the flow based on the
design requirements outlined below. The system pipework shall have a total length of
866.5 M.
The system design parameters are as follows;

Pump Design Flow Rate: 46 m3/h.


Control Valve Design Flow Rate: 10 m3/h.
Design Pipe Velocity: 1.55 m/s.

Figure 3.2.1: Auto-Sized Pump, Pipes & Control Valve.

We are required to calculate the duty pressure rise and NPSHa for the pump, the Cv for
the control valve and the optimum pipe diameter for the plant.
Step 1: Using the lessons learned from Liquid Design Exercise 1, place the three
boundaries (one inlet and two outlets) on the flowsheet. Select Steel Pipe or Duct from
the Pipes tab on the Component Palette and draw the model layout by positioning the
mouse selector directly over the inlet boundary (node 1) and left mouse-clicking in the
location of end node 2. Click directly over bend node 2 and terminate the pipe in the
location of bend node 3. Follow this procedure until the model has been developed as per
Figure 2.2.1. You will notice as you develop the model that the software automatically
assigns a bend where we have two pipe connections and a tee where we have three pipe
connections. Where we have a tee junction, it is important to correctly assign the branch
(RED DOT) position. In this case, the branch is pipe node -8.
Note, the RED DOT denotes a branch at tee junctions and the channel (combined flow)
at wye junctions. Further information on the correct assignment of the RED DOT is
available from the Nomenclature field on the Input Inspector for tee/wye junctions and
also in the Help file. Figure 3.2.2 provides an overview of the RED DOT positioning.

FluidFlow Designer Handbook

Page 14

Figure 3.2.2: Red Dot Positioning.

When the connectivity is complete, insert a pump by selecting the Boosters tab on the
Component Palette, choose the Centrifugal Pump icon and insert in the location shown
on the diagram. You will notice a RED DOT appear when we insert a pump into a model.
This simply denotes the discharge side of the pump. This can be switched using the field
titled Discharge Pipe (RED) on the Input Inspector. Take care to assign the RED DOT
correctly. Note, if this model included a check valve, we would also need to review the
Discharge Pipe (RED) assignment for this component to ensure matches that of the
pump.
Finally, we must select the Controllers tab on the Component Palette, choose the Flow
Control Valve icon and insert in the position shown. We are now ready to edit our design
data.
Step 2: The next step is to edit the default data for each of the nodes placed on the
flowsheet. Lets start with our boundaries. Select all boundaries by clicking on the List
tab on the Data Palette and placing a check-mark in the option titled Boundaries.

Figure 3.2.3: Red Dot Positioning.

You will see all boundaries in the model in a list. Select the first boundary, hold the
SHIFT key and select the last. All boundaries will now be highlighted and marked off on
the flowsheet. We can then select the Input Inspector and edit the properties for all
three nodes at once.
Lets change the Pressure Unit for all three nodes from atm to barg. Click anywhere on
the flowsheet (not on the actual model). This allows us to deselect these nodes. Now

FluidFlow Designer Handbook

Page 15

select the inlet boundary and set the inlet pressure to 1.3 barg and fluid temperature to
20oC. Select one exit boundary on the flowsheet and whilst holding the shift key, select
the second. Once again, select the Input Inspector and set the pressure to 1.1 barg for
both exit nodes at once.
Note, the only important parameter for the exit boundaries is pressure. All other
parameters such as the default temperature of 15 oC will be overwritten by the actual
flowing fluid conditions.
Now we can consider the pipes. We need to define the lengths as shown in Figure 3.2.1
and described in Table 3.2.1 using the Input Inspector.
Table 3.2.1: Pipe Lengths
Pipe User Number
-1
-6
-2
-3
-7

Pipe Length (M)


1.5
5.0
50
750
25

Pipe User Number


-4
-5
-8
-9

Pipe Length (M)


25
10
5
5

By default, all pipes are 2 inch schedule 40. As we are going to allow the software to
automatically size the pipes for this system, we are going to leave this nominal pipe size
for the moment. However, we will define the design velocity of 1.55 m/s for all pipes in
the system by multi-select all pipes.
Select; Edit | Select | Select Pipes. All pipes will now be marked-off on the flowsheet.
From the Input Inspector, change the field for Sizing Model from Economic Velocity to By
Velocity. We can then enter a value of 1.55 for the Design Velocity and m/s for Velocity
Unit.
Select the pump node followed by the Input Inspector. From here we can set the
Automatically Size function from Off to On. Set the Sizing Model to Size for Flow and
enter a value of 46 for Design Flow and m3/h for the field Flow Unit.
Finally, select the control valve on the flowsheet and from the Input Inspector, set the
Automatically Size function from Off to On. As the control valve is a butterfly valve, we
need to set the Control Valve Type to Butterfly (Xt=0.38). The default Design Flow and
Flow Unit is 10 m3/h which matches our design requirement. We shall therefore retain
this value.
This system is based on all nodes having an elevation of zero and as such, we can retain
the default values.
Step 3: Calculate the model using the Calculate button located at the top of the
flowsheet. You may now notice that all pipes have been highlighted in RED, indicating we
have a warning message associated with each pipe element. If we select the Messages
tab on the Data Palette, we can view all warnings for the model including a description of
each.
In this case, we have seven high velocity warnings. If we select pipe -1 on the flowsheet
followed by the Results tab, we can see all calculated values for this specific pipe. Figure
3.2.4 provides an overview of these results.

FluidFlow Designer Handbook

Page 16

Figure 3.2.4: Pipe -1 Calculated Results.

As we can see in Figure 3.2.4, based on the default 2 inch schedule 40 pipe, the actual
flowing velocity of the fluid is 5.90 m/s. The high velocity warning is enunciated since
this flowing velocity is higher than the maximum velocity level (4 m/s) set under;
Options | Warnings & Hints | Liquid Limits.
As we have defined a design velocity for each pipe of 1.55 m/s, the software has
automatically calculated the Exact Velocity Size required to match this design
requirement. In the case of pipe -1, the Exact Velocity Size is 102.5 mm and we can see
that the 2 inch schedule 40 pipe equates to an internal diameter of just 52.5mm.
We can now view the results for each pipe and consider changing the actual pipe
diameter to the next closest standard pipe size to that suggested by the software. The
pipe sizes suggested by the software are summarised in Table 3.2.2.

FluidFlow Designer Handbook

Page 17

Table 3.2.2: Auto-Sized Pipes.


Pipe User
Number

-1
-6
-2
-3
-7

Exact
Velocity
Pipe Size
(mm)
102.5
102.5
102.5
102.5
102.5

Standard
Pipe Size
Selected
4
4
4
4
4

Inch
Inch
Inch
Inch
Inch

Pipe User
Number

-4
-5
-8
-9

Exact
Velocity
Pipe Size
(mm)
90.8
90.8
47.8
47.8

Standard
Pipe Size
Selected
3
3
2
2

Inch
Inch
Inch
Inch

We can multi-select pipes -1 to -7 by holding the SHIFT key and left mouse-clicking on
each pipe and change the Nominal Size to on the Input Inspector to 4 inch Schedule 40.
When you select the field Nominal Size, click on the drop-down menu which appears on
the right hand side as this will open the pipes database. From this database, click on the
arrow adjacent 4 Inch as this will expand the list of available pipe classifications for
this size. Select Schedule 40 followed by, OK.
We can follow the same steps when changing the Nominal Size for pipes -4 & -5 (3
Inch). Note, pipes -8 & -9 shall be retained as 2 inch Schedule 40.
Now we can recalculate the model to study the effects of these changes. The pipe
warnings should have disappeared and we should now only have a single warning
associated with tee junction, node 9. This warning indicates that the calculated K value
for the tee junction is outside the range of experimental data based on Idlechik
relationships.
Note, FluidFlow calculates correctly for reducing Tees, provided that you are using
Idelchik, Miller or SAE types. This tee junction has connecting pipe sizes 4 Inch, 3 Inch
and 2 Inch and pressure conversion effects from velocity to static or vice versa are taken
into account when calculating pressure losses at the tee. Click on the tee, select the
Input Tab and click the Nomenclature row in the Input Inspector if you need further
information. For tees having 3 different branch sizes, the loss relationships need to be
extrapolated and you may find that you have warning messages to this effect.
Warning messages are there to help you decide if you need to make design changes. In
this case the warning messages refer to the possible loss of calculation accuracy in the
tee junctions because relationship data has been extrapolated. Since there are no other
available pressure loss relationships available for these types of reducing tees we have
no choice but to accept this warning. Still it is worthwhile checking on the calculated K
values to ensure these are within an expected range (-2 to 10). You can also cross-check
by using another tee definition/loss relationship (say Miller type) and verify that the
calculated K values and pressure losses are similar. This is the case here and so we can
safely ignore the warnings.
We can now review the calculated results for the pump (Figure 3.2.5).

FluidFlow Designer Handbook

Page 18

Figure 3.2.5: Pump Results.

Based on our design flow rate and system configuration, the pump will have a duty
pressure rise of 189778 Pa. The NPSHa is calculated as 23.4 m fluid. If we wished to
view the duty pressure rise using m fluid (head units), we can simply, right mouse-click
on the Results tab and select Results Units. Change the field for Pressure/Head Drop to
m fluid and set the desired decimal point position. In this case, the duty pressure rise is
19 m fluid. We know this to be true since H = P/*g (H = 189778/998.4*9.80665 = 19
m fluid).
We now have enough information to approach a pump vendor to select a suitable pump
for our system.
The calculated Cv for the control valve is 30.0 usgm/psi and we know the flow rate and
pressure loss. Figure 3.2.6 outlines the results for the control valve.

FluidFlow Designer Handbook

Page 19

Figure 3.2.6: Control Valve Results.

We therefore also have enough information to approach a vendor to select a suitable


valve for our system.
Once the suppler has provided us with the performance data (curve relationships etc),
we can define this information into the software database and model these specific
component in our system. Note, you only need to add a component to the database once
as it will be stored for all future modeling projects.
We can also complete a quick check on the pumps and valves already stored in the
database with the view to selecting a suitable element. Lets start with the control valve.
Select; Tools | Equipment Performance | Control Valve Performance. A new dialogue will
appear as per Figure 3.2.7.

FluidFlow Designer Handbook

Page 20

Figure 3.2.7: Control Valve Performance.

As we can see, having viewed a number of valves, the Keystone 2 Inch Butterfly Valve
represents a reasonable valve selection which will have a valve opening position of
approximately 43.6%.
Lets view this valve in the database by selecting; Database | Control Valves | Keystone
| 2 Inch Butterfly Valve. Select the field titled Curve Data as this will open the Curve-Fit
data as per Figure 3.2.8.

FluidFlow Designer Handbook

Page 21

Figure 3.2.8: 2 keystone Butterfly Valve Curve Relationship

We can actually see from this curve that, a Cv of 30 (y axis) would represent a valve
position of approximately 46% (x axis) which is what the software has determined.
We can close this data by selecting OK on the Curve Fit dialogue and OK on the
Database Editor - Controllers.
Now lets consider the pump. Select; Tools | Equipment Performance | Pump
Performance. Enter a value of 46.0 m3/h for the Design Flow. As we can see in Figure
3.2.9, having viewed a number of pumps, the Peerless Pump (Model 8196 2x3x6)
represents a reasonable selection. Based on this design flow rate, the pump will have an
efficiency of approximately 76.03% whilst the pump BEP is 76.88%. The duty head
would be 23.54 m fluid with a NPSHr of 2.44 m fluid.

FluidFlow Designer Handbook

Page 22

Figure 3.2.9: Pump Performance.

Lets model this specific valve and pump in the system. Firstly, select the valve on the
flowsheet and set Automatically Size to Off. By coincidence, the 2 Butterfly Valve
provided by default is the actual Keystone valve we wish to model. You can check this by
clicking on the drop-down menu which appears when you select the field titled Valve
Model on the Input Inspector. We will therefore retain this default selection.
Finally, select the pump node in the model and from the Input Inspector, set
Automatically Size to Off. The Pump Model provided by default is the actual Peerless
pump we wish to model. Once again, we will retain this default selection. Note, if you
wished to model an alternative pump from the database, you simply select the Pump
Model field, access the pumps database and choose the desired alternative pump.
Now we have selected our pump and valve, select Calculate to refresh the results based
on these design changes. Select the pump on the flowsheet followed by the Results tab.
Note the software has established the pump flow rate, duty pressure rise, efficiency,
power NPSHa and NPSHr. This data can be seen in Figure 3.2.10.

FluidFlow Designer Handbook

Page 23

Figure 3.2.10: Pump Results.

The flow rate is higher than what we require, i.e. 50 m 3/h as opposed to 46 m 3/h. We
may therefore be in a position to optimise the performance of this pump. Before we do
so, lets view the Chart Tab on the Data Palette. Figure 3.2.11 provides an illustration of
the duty point on the pump performance curves.

Figure 3.2.11: Pump Performance Curves.

Note, if the system curve doesnt appear on your Chart plot, select the icon on the top
left corner of the chart (
) as this will allow you to turn on/off the various curves
and also change the flow and head units.
Lets now attempt to optimise the plant. Select the pump on the flowsheet and from the
Input Inspector, we can see the Impeller Diameter is set to 5.5 (inches) and the
Operating Speed is set to 2850 (RPM). If we click on either of these fields, a new
dialogue appears titled Set Booster Changes (Figure 3.2.12).

FluidFlow Designer Handbook

Page 24

Figure 3.2.12: Pump Speed & Impeller Diameter Range.

From here we can see that this pump has a minimum speed of 1450 and a maximum
speed of 3600 RPM. The impeller diameter has a minimum size of 4.0 inches and a
maximum of 6.1 inches. We can therefore set about modeling changes in either impeller
diameter size or pump operating speed.
Lets try reducing the pump speed to 2600 RPM and select OK. Once again, select
Calculate to refresh our results. Figure 3.2.13 provides details of the updated results.

Figure 3.2.13: Pump Results 2600 RPM.

As we can see, the flow rate now matches our requirement, the duty pressure rise is 19
m fluid which again, matches the auto-sized pump requirements and the duty power has
reduced from 4 kW to just 3.1 kW. The NPSHa is also still within limits. We have
therefore optimised the system and you will note we have an additional warning
message for the pump indicating that the booster affinity laws have been applied.
If we select the control valve on the flowsheet followed by the Results tab, we can see
the updated results for the valve (Figure 3.2.14). The valve is still controlling the desired
flow rate to 10 m3/h with a opening position of 43 %.

Figure 3.2.14: Control Valve Results @ 2600 RPM Pump Speed.

We can also view the duty point on the control valve curve by selecting the Chart tab
(Figure 3.2.15).

FluidFlow Designer Handbook

Page 25

Figure 3.2.15: Control Valve Duty Point.

If we view the results for pipe -4, we can see that the remainder of the flow 36 m3/h is
now passing through this section of the plant which is what we would expect to see (46
10 = 36 m3/h ).
This model has demonstrated how we can auto-size pumps, control valves and pipes.
The software allows us to auto-size relief devices, pressure control valves, fans, PD
pumps, rotating PD pumps, orifice plates, nozzles and venturi tubes.

FluidFlow Designer Handbook

Page 26

4 Compressible Flow Modeling.


4.1

Calculation Settings Compressible Flow.

When modeling liquid systems, we can immediately start building the model on the
flowsheet, edit default data and run the calculation. When modeling gas flow systems,
we firstly need to consider the Calculation Settings we wish to use for the simulation.
If we are modeling a system where we intend to define a flow rate using volumetric units
(m3/h, ft3/min) on the flowsheet, we need to give due consideration to the reference
volumetric flow units used.
Generally the density of a gas flowing in any piping system is not constant. This means
that it is not meaningful to specify gas flowrate in actual volume flow units without
providing the temperature and pressure base at which the actual volume is referred to.
It is common practice to refer to gas volume flow against a specified basis.
There are many bases available for referencing gas volumes. Today the most universally
accepted reference is metric Standard Conditions (STP) which is defined by ISO 5024 at
15C and 101325 Pascals. The American Gas Association and the International Gas
Union both support the use of this reference.
Normal conditions (NTP), defined as 0C and 101325 Pascals, is still used throughout
Europe and FluidFlow can use either basis for your gas system. By setting the reference
volumetric flow units, FluidFlow will establish the gas density and estimate all fluid
physical properties.
FluidFlow also allows us to model gas flow systems using mass flow units, i.e. kg/h, lb/h
etc. This removes any ambiguity in relation to the gas flow rate, density etc and is often
a useful approach to use when modeling gas systems.
To set your reference gas volumetric flow units, select; Options | Calculation | Gas.

Figure 4.1.1: Gas Calculation Settings.

FluidFlow Designer Handbook

Page 27

When developing your model, you can always take a quick glance at the Status Bar at
the bottom of the flowsheet as this allows us to quickly determine which reference gas
volume flow units have been assigned to the open flowsheet. Figure 4.1.2 shows that,
for this particular example, the flow units assigned are STP (15C and 101325 Pascals).

Figure 4.1.2: Status Bar.

Note, this section of the Status Bar will only be present if the Gas Module is activated.
4.2

Gas System Design Exercise 1.

In this example system, we have an offshore natural gas production platform exporting
gas at 70 bara and 80oC via a 100.15 km (100150 M) of 20 buried sea-bed pipeline.
The pipeline is modelled in three sections as follows;
Table 4.2.1: Pipe Data.
Description

Pipe
Length
(M)

Overall Heat
Transfer
Coefficients
(W/m2 oC)

Insulation
Thickness
(mm)

19

Local
(Air/Sea)
Ambient
Temperature
(oC)
10

Pipe segment
exposed to air (no
coating)
Pipe segment
exposed to sea
coated in 3mm
polyethylene
Pipe segment
running along the
sea bed coated with
1.5mm PVC and
75mm concrete

50

100

92

25

100000

14

25

25

The design flow rate at the system outlet is 6000000 Sm3/day.


The gas composition is as set out in Table 4.2.2.
Table 4.2.2: Gas Composition.
Mol %
4.0
3.0
82.0
8.0
2.0
1.0

Component Fluid
Nitrogen
Carbon Dioxide
Methane
Ethane
Propane
Isobutane

Step 1: Create this new fluid mixture in the fluids database. Select; Database | Fluids.
This will open a new dialogue titled Fluid Editor (Figure 4.2.1).

FluidFlow Designer Handbook

Page 28

Figure 4.2.1: Fluid Editor.

Select the option titled New Mix from the bottom left hand corner. We will now be
presented with a dialogue box asking us to give our new fluid a unique name. Enter the
name Gas Exercise 1 and select OK. A new dialogue will appear titled New Mixture - Gas
Exercise 1 (Figure 4.2.2).

FluidFlow Designer Handbook

Page 29

Figure 4.2.2: New Mixture Dialogue.

We can now choose any of the fluids already in the fluids database and assign them to
the new mixture. You can scroll up/down through the list of fluids and double click on the
fluid to add it to the mixture. When you double-click the fluid on the left hand side, it will
automatically be moved across to the right hand side where we create the mixture.
We have added each of the fluids to the mixture together with the percentage of each.
We also set the Mixture Type to Mole %, unchecked the option Allow Phase Change and
placed a check-mark in the box titled Gas Phase Only. This simply means that we dont
wish to model the fluid in two-phase but in gas phase only.
The final fluid mixture should appear as per Figure 4.2.3.

FluidFlow Designer Handbook

Page 30

Figure 4.2.3: New Gas Mixture.

Select OK on the New Mixture - Gas Exercise 1 dialogue and OK on the Fluid Editor
dialogue. We have now added this new mixture to the database.
Step 2: The next step is to set the Calculation Settings for the flowsheet where we will
build the model. We know the design flow rate in in volumetric units and is 6000000
Sm3/day. This corresponds to a flow rate based on STP conditions. WE can therefore set
our gas volumetric flow units accordingly.
Step 3: The next step is to lay out the model as per Figure 4.2.4.

FluidFlow Designer Handbook

Page 31

Figure 4.2.4: Buried Seabed Natural Gas System.

Place a Known or Assigned Pressure node (available from the Boundaries tab) on the
flowsheet to represent the system inlet. Then, place a Known or Assigned Flow node
(available from the Boundaries tab) on the flowsheet to represent the system outlet.
Select Steel Pipe or Duct from the Pipes tab on the Component Palette and place the
mouse selector directly over the Known or Assigned Pressure node. Left mouse-click on
this inlet boundary to connect the pipe. Then, left mouse-click in the position of the first
bend (sea level) in Figure 4.2.4. The pipe will have terminated with an Open Pipe node.
Continue developing the model connectivity by left mouse-clicking on the Open Pipe
node and terminate this second pipe in the position of the second bend. This pipe will
also have terminated with an Open Pipe node but you should see the first Open Pipe
node has now changed to a bend automatically.
Continue developing the model connectivity by left mouse-clicking on the latest Open
Pipe node and terminate this final pipe in the position of the outlet boundary. The model
connectivity should now be complete.
Step 4: Now we have completed the model connectivity, we can begin to edit the default
design input information.
The data-entry for the main inlet node (node 1) should appear as per Figure 4.2.5.

FluidFlow Designer Handbook

Page 32

Figure 4.2.5: System Inlet Data-Entry.

Note, this node has taken account of the inlet elevation.


The data-entry for the main outlet node (node 4) should appear as per Figure 4.2.6.

Figure 4.2.6: System Outlet Data-Entry.

Lets now consider the bends. The data-entry for the bend located at sea level is set out
in Figure 4.2.7.

Figure 4.2.7: Sea Level Bend Data-Entry.

The data-entry for the final bend located at the sea floor is set out in Figure 4.2.8.

FluidFlow Designer Handbook

Page 33

Figure 4.2.8: Sea Floor Bend Data-Entry.

Now we can consider the pipes. We need to define the lengths as shown in Figure 4.2.4
and described in Table 4.2.1 using the Input Inspector.
The data-entry for the first pipe (shown in red) is set out in Figure 4.2.9.

Figure 4.2.9: Pipe Node -1 Data-Entry (Red Pipe).

The data-entry for the second pipe (shown in green) is set out in Figure 4.2.10.

FluidFlow Designer Handbook

Page 34

Figure 4.2.10: Pipe Node -2 Data-Entry (Green Pipe).

The data-entry for the final horizontal pipe (shown in orange) is set out in Figure 4.2.11.

FluidFlow Designer Handbook

Page 35

Figure 4.2.11: Pipe Node -3 Data-Entry (Orange Pipe).

Step 3: Calculate the model using the Calculate button located at the top of the
flowsheet. The model solves without any warnings.
We can see that FluidFlow has estimated the outlet temperature and pressure of the gas
to be 3.7oC and 50.1 bara. This correlates well as a test conducted by others produced
an outlet temperature and pressure of 4.1oC and 50.9 bara
Note, you can also view the gas density profile as the gas flows along the length of the
100km buried pipeline. Lets consider pipe node -3. Select this pipe on the flowsheet and
select the Chart tab on the Data Palette. Select the drop down menu as shown in Figure
4.2.12.

Figure 4.2.12: Chart Options.

FluidFlow Designer Handbook

Page 36

Choose the Density option. You should now see a curve relationship as outlined in Figure
4.2.13.

Figure 4.2.13: Density vs Pipe Length.

The above graph provides a classic representation of a density profile along a gas
pipeline.

FluidFlow Designer Handbook

Page 37

5 Two-Phase (Liquid-Gas) Flow Modeling.


There are essentially three different approaches you can take to modelling two-phase
systems in FluidFlow.
Option 1: Specify the quality (vapor quality) and design pressure of the two-phase fluid
at the inlet boundaries in which case, FluidFlow will automatically determine the fluid
physical properties, i.e. temperature etc.
Option 2: Create liquid and gas mixtures dynamically on the flowsheet. When we adopt
this approach, FluidFlow will automatically establish where the fluids mix, detect any
changes in fluid phase state and apply the appropriate pressure loss correlation.
Option 3: Specify the design inlet pressure and temperature of the fluid in which case,
FluidFlow will automatically determine the fluid physical properties, i.e. vapor quality etc.
Note, FluidFlow will automatically track fluid phase state throughout your system and
apply the appropriate pressure loss correlation. This section shall detail each of these
three approaches.
Before we consider these design approaches, we must firstly consider the Calculation
Settings we wish to apply to the system.
5.1

Calculation Settings Two-Phase Flow.

When modeling two-phase systems, we firstly need to consider the Calculation Settings
we wish to use for the simulation.
FluidFlow includes eight different correlation options for two-phase systems which are
outlined in Figure 5.1.1. To view or select any of these options select; Options |
Calculation | Two Phase.

Figure 5.1.1: FluidFlow Two-Phase Correlations.

The default two-phase correlation setting is Whalley Criteria. The Whalley Criteria option
means the software will automatically consider the fluid physical properties (viscosity,
mass flux etc) and apply the most appropriate correlation from the three available

FluidFlow Designer Handbook

Page 38

(Friedel, Chisholm or Lockhart Martinelli) as part of the Whalley Criteria. You can
however select any of the correlations shown.
Note, when building or reviewing any model, we can quickly glance at the Status Bar at
the bottom of the flowsheet to determine what calculation settings have been selected
for the model we are developing. As we can see in Figure 5.1.2, the Whalley Criteria has
been selected in this particular sample case.

Figure 5.1.2: FluidFlow Status Bar.

Another key point to note is that, if we are creating liquid-gas mixtures dynamically on
the flowsheet and we intend to define a volumetric flow rate for the gas, we need to
consider the STP and NTP settings. Note, there is further information on this topic in the
gas flow modeling section of this handbook.
To set your reference gas volumetric flow units, select; Options | Calculation | Gas.
Lets now consider the different means of modeling our two phase systems.
5.2

Option 1: Two-Phase Design Exercise 1 (Changing Quality System).

In this example we have a single fluid (R-152a) flowing through a system from a known
pressure (node 1) at 1.18 atm through a shell and tube heat exchanger via a network of
pipework. In developing this model, a fluid vapor quality of 18% (0.18) has been set at
the inlet of the system - an approach which is often used for steam systems. When we
use this approach, the software automatically calculates the fluid temperature which will
be shown in the Results tab.
Lets build the model as shown in Figure 5.1.1 using schedule 40 steel pipework. The
system contains a single shell and tube heat exchanger with 30kW of heat energy being
added to the system. The system includes elevation changes which are noted on the
illustration below.

Figure 5.1.1: Changing Quality R152a Refrigerant System.

FluidFlow Designer Handbook

Page 39

Step 1: The first step is to lay out the model as per Figure 5.1.1. Place a Known or
Assigned Pressure node (available from the Boundaries tab) on the flowsheet to
represent the system inlet. Select Steel Pipe or Duct from the Pipes tab and develop the
model connectivity as shown. Notice when you terminate the pipe at the end of the
model, the software automatically fits an Open Pipe node which of course assumes the
pipe outlet is at atmospheric pressure. If you had planned to set a design pressure in
this location then, we would need to change this Open Pipe node to a Known or Assigned
Pressure node. We are going to proceed with an Open Pipe node in this design case.
Lets add the heat exchanger. Select the Heat Exchangers tab on the Component Palette
followed by Shell and Tube Heat Exchanger and insert into the model in the location
shown.
Step 2: Now we have completed the model connectivity, we can begin to edit the default
design input information.
The data-entry for the main inlet node (node 1) should appear as per Figure 5.1.2.

Figure 5.1.2: System Inlet Data-Entry.

Now we can consider the pipes. We need to define the lengths as shown in Figure 5.1.1
and described in Table 5.1.1 using the Input Inspector.
Table 5.1.1: Pipe Lengths
Pipe User
Number

Pipe
Length (M)

-1
-2
-3
-4

10
8
8
5

Nominal
Size
2
2
2
2

Inch
Inch
Inch
Inch

Pipe User
Number

Pipe
Length (M)

Nominal
Size

-5
-6
-7

10
10
5

3 Inch
3 Inch
3 Inch

Now we need to consider changes in elevation. We set elevation changes at boundaries


and fittings. We have already set the elevation for the main inlet boundary node. Lets
set the elevation of all other fittings in the model in as shown in Figure 5.1.1 and
described in Table 5.1.2. We can complete this data-entry using the Input Inspector.

FluidFlow Designer Handbook

Page 40

Table 5.1.2: Plant Elevations


Description

Elevation (M)

Description

Elevation (M)

Known Pressure
Node 1
Bend Node 2
Bend Node 3
Bend Node 4

Heat Exchanger
Node 8
Bend Node 5
Bend Node 6
Open Pipe Node 7

6
12
6

0
0
4

Note, all other Input properties for the bends and open pipe node shall remain as
default.
The final data-entry step is for the heat exchanger node. In this case, we will leave the
Pressure Loss Model as Standard Relationships. This model allows you to enter the
geometric characteristics of the heat exchanger in which case, FluidFlow will solve the
equations noted in the Help file under; Shell and Tube Exchanger | Calculation Method.
For simplicity, we shall retain the default values for Number of Tubes, Tube Diameter
etc.
As we know we have 30 kW of heat being added to the plant via the heat exchanger, we
can select the heat exchanger on the flowsheet and from the Input Inspector of the Data
Palette, set the field titled Heat Loss Model from Ignore Heat Loss/Gain to Fixed Heat
Transfer. This reveals a number of additional fields where we can define the heat
transfer direction to/from the plant.
The data-entry for this heat exchanger should be completed as set out in Figure 5.1.3.

Figure 5.1.3: Heat Exchanger Data-Entry.

Step 3: Calculate the model using the Calculate button located at the top of the
flowsheet. The model solves without any warnings.
Note, this system will be solved using the Whalley Criteria. The Whalley Criteria is the
default two-phase correlation. Note, you can choose from eight correlation options
available in FluidFlow by selecting; Options | Calculation | Two Phase (Figure 5.1.4).

FluidFlow Designer Handbook

Page 41

By choosing Whalley Criteria, the software will automatically consider the fluid physical
properties (viscosity, mass flux etc) and apply the most appropriate correlation from the
three available (Friedel, Chisholm or Lockhart Martinelli) as part of the Whalley Criteria.

Figure 5.1.4: FluidFlow Two-Phase Correlations.

Note, when building or reviewing a model, we can quickly glance at the Status Bar at the
bottom of the flowsheet to determine what calculation settings have been selected for
the model we are developing. As we can see in Figure 5.1.5, the Whalley Criteria has
been selected for this particular design case.

Figure 5.1.5: FluidFlow Status Bar.

If we select the first pipe in the model (node -1) and view the results, we can see that it
has solved using the Friedel correlation and the liquid and gas superficial velocities are
also calculated at the inlet and outlet of each pipe/element. Figure 5.1.6 provides an
overview of the results calculated for this pipe.

FluidFlow Designer Handbook

Page 42

Figure 5.1.6: Pipe -1 Calculated Results.

This is an example of two-phase flow with changing quality. This means that the vapor
mass fraction is not constant and there is mass transfer between the fluid phases. You
can see this in the results of all flowsheet elements.
Examine the vapor quality entering and leaving each node or pipe and you will see that
quality is increasing as we flow through the system. This is because the pressure falls as
the fluid flows down a pipe (or across a bend) and as a result, some of the liquid boils to
form additional vapor. This is called flashing, and FluidFlow assumes that instantaneous
isenthalpic flashing occurs. You should also notice that velocities are increasing and that
mixture densities are decreasing.
At the heat exchanger we are adding some 30,000 watts of heat and this has the effect
of vaporising additional liquid across this element. The vapor quality therefore increases
from 0.1982 (19.82%) to 0.4605 (46.05%).
As an exercise change the Heat Loss Model at the exchanger from Fixed Transfer Rate to
Ignore Heat Loss. What would you expect to happen to the vapor quality leaving the
exchanger ? It should decrease. You should also note that system flow will increase as a
result.

FluidFlow Designer Handbook

Page 43

FluidFlow also allows you to view the flow pattern map for any pipe in your two-phase
model. For instance, select pipe -1 and on the Chart tab, select the flow pattern map
option (Figure 5.1.7).

Figure 5.1.7: Flow Pattern Map Selection.

The software will automatically generate a flow pattern map for the pipe. The flow
pattern map for pipe node -1 should appear as per Figure 5.1.8.

Figure 5.1.8: Flow Pattern Map Selection (Pipe -1).

FluidFlow Designer Handbook

Page 44

We can see that the flow pattern for this pipe is just on the border of the stratified wavy
flow regime. Lets consider the following pipe in the model (node -2).
This is an inclined pipe which changes from an elevation of 6 M to 12 M. If we view the
flow pattern map, we can see that the flow pattern is now annular mist (Figure 5.1.9).
This is because the gas superficial velocity has increased as a result of the pipe
inclination. A quick check of the results for both pipes should confirm this.

Figure 5.1.9: Flow Pattern Map Selection (Pipe -2).

FluidFlow Designer Handbook

Page 45

5.3

Option 2: Two-Phase Design Exercise 2 (Constant Quality System).

In this example we shall create a two-phase mixture dynamically on the flowsheet. This
requires a minimum of two inlet boundaries. One shall include a liquid and the other a
gas. At the point where the two fluids mix, the software will automatically detect the two
phase conditions and apply the two phase correlation. The design flow rate for the liquid
(water) shall be 25 usgpm and 0.08023 kg/s for the air. The design temperature of the
water shall be 29oC and for the 29oC air.
Note, this is an example of a constant quality system whereby the vapor quality of the
fluid doesnt change as the fluid flows through the system. This is attributed to the fact
that we have a fixed flow of gas and liquid entering the system.
Lets build the model as shown in Figure 5.2.1 using schedule 40 steel pipework. The
system contains a single plate heat exchanger with a design temperature increase of
30oC across element. The elevation of all nodes in this system will be zero (default
setting).

Figure 5.2.1: Constant Quality Air/Water System.

Step 1: The first step is to lay out the model as per Figure 5.2.1. Place two Known or
Assigned Flow nodes (available from the Boundaries tab) on the flowsheet to represent
the two system inlets.
Place two Known or Assigned Pressure nodes (available from the Boundaries tab) on the
flowsheet to represent the two system outlets.
Place a single Connector node (available from the Junctions tab) on the flowsheet to
represent the point where the two system fluids mix.
Add a Knock-Out Pot (liquid/vapor separator) to the flowsheet in the position shown.
This node is available from the Heat Exchangers tab.
Select Steel Pipe or Duct from the Pipes tab and develop the model connectivity as
shown.
Step 2: Now we have completed the model connectivity, we can begin to edit the default
design input information.

FluidFlow Designer Handbook

Page 46

The data-entry for the main inlet nodes (node 1 & 2) should appear as per Figures 5.2.2
& 5.2.3.

Figure 5.2.2: Data-Entry - Node 1 (Water Inlet).

Figure 5.2.2: Data-Entry - Node 2 (Air Inlet).

The data-entry for both outlet boundary nodes shall be based on the default data, i.e. 1
ATM Stagnation Pressure etc. We therefore dont need to edit the design input data
these nodes.
Now we can consider the pipes. We need to define the lengths as shown in Figure 5.2.1
and described in Table 5.2.1 using the Input Inspector.
Table 5.2.1: Pipe Lengths
Pipe User
Number

Pipe
Length (M)

Nominal
Size

Pipe User
Number

Pipe
Length (M)

Nominal
Size

-1
-2
-6
-3

0.5
0.5
60
60

2 Inch
2 Inch
50.8mm ID
50.8mm ID

-4
-5
-7

5
10
10

6 Inch
2 Inch
2 Inch

When completing the data-entry for the pipes, we shall set the Status of both pipe nodes
-1 & -2 to Ignore Pressure Loss on the Input Inspector. This means that the pressure
loss for these pipes will be excluded from the calculation.

FluidFlow Designer Handbook

Page 47

We shall retain the default settings for the Connector node which means, we just need to
complete the data-entry for the heat exchanger and Knock-Out Pot.
Lets edit the heat exchanger data. In this case, we will leave the Pressure Loss Model as
Standard Relationships. This model allows you to enter the geometric characteristics of
the heat exchanger in which case, FluidFlow will solve the equations noted in the Help
file under; Plate Exchanger | Calculation Method. For simplicity, we shall retain the
default values for Number of Plates, Plate Width etc.
As we know we have 30oC of heat being added to the plant via the heat exchanger, we
can select the heat exchanger on the flowsheet and from the Input Inspector of the Data
Palette, set the field titled Heat Loss Model from Ignore Heat Loss/Gain to Fixed
Temperature Change. This reveals a number of additional fields where we can define the
heat transfer direction to/from the plant. The data-entry for the heat exchanger is as set
out in Figure 5.2.3.

Figure 5.2.3: Heat Exchanger Data-Entry.

The last element to define is the Knock-Out Pot. The data-entry for this node is set out in
Figure 5.2.4.

Figure 5.2.4: Knock Out Pot Data-Entry.

Note, in this design case, the pipe outlet at the top of the Knock-Out Pot is pipe -4 and
the pipe connected to the bottom of the Knock-Out Pot is pipe node -5. We have
therefore assigned the liquid and gas outlets in accordance with this connectivity.

FluidFlow Designer Handbook

Page 48

Step 3: Before we solve the model, we need to consider the Calculation Settings. In this
particular design case, we are going to solve the system using the Beggs Brill
correlation. To assign this correlation to the system, select; Option | Calculation | Two
Phase (Figure 5.2.5).

Figure 5.2.5: Calculation Settings - Beggs Brill.

Calculate the model using the Calculate button located at the top of the flowsheet. The
model solves without any warnings.
Once again, we can quickly glance at the Status Bar at the bottom of the flowsheet to
determine what calculation settings have been selected for the model we are developing.
As we can see in Figure 5.2.6, the Beggs Brill correlation has been selected for this
particular design case.

Figure 5.2.6: Status Bar.

If we select pipe node -3 in the model and view the results, we can see that it has solved
using the Beggs Brill correlation and the flow pattern is Distributed (Figure 5.2.7).

FluidFlow Designer Handbook

Page 49

Figure 5.2.7: Pipe -3 Calculated Results.

This is an example of two-phase flow with constant quality. This means that the vapor
mass fraction is constant and there is no mass transfer between the fluid phases. It
doesnt mean that the pressure loss per unit length is constant or that the velocity
between the two phases is constant.
In the first pipe section after mixing (pipe -6) you can see that the gas superficial
velocity increases from the start to the end of pipe -6. For 60m of pipe -6, the total
pressure loss is 146790 Pa, but the friction loss is 145349 Pa. Since the pipe is
horizontal the difference is the acceleration loss. After the exchanger the mixture has
experienced a temperature increase of 30 C. The total pressure loss in the pipe after
the exchanger (-3) is 208629 Pa (pipe -3 is identical in length and diameter to -6).
This is because gas volume and velocity as well as other fluid properties have changed
with the increase in temperature in the outlet pipe. You can get a feel for the differences
by displaying the Beggs Brill flow pattern map. To do this click on the pipe, then click on
the chart tab in the Data Palette and then use the display button to select the flow
pattern map. The flow pattern map for pipe -3 can be seen in Figure 5.2.8.

FluidFlow Designer Handbook

Page 50

Figure 5.2.8: Flow Pattern Map Selection (Pipe -3).

5.4

Option 3: Two-Phase Design Exercise 3 (Changing Quality System).

The main difference between this changing quality system and that in the example titled
Two-Phase Design Exercise is that, in this system, we have specified the design fluid
temperature and pressure at the inlet whereas in the latter case, we specified the actual
vapor quality.
Before we begin, we need to consider the two-phase calculation settings. In this
example, we are going to set the two-phase correlation to Whalley Criteria (Options |
Calculation | Two Phase | Whalley Criteria.
In the following example we have a single fluid (water) flowing through a pressure
control valve from a known pressure inlet (node 1) at 2 ATM & 120oC to a second known
pressure outlet node at 1 ATM.
Lets build the model as shown in Figure 5.3.1 using schedule 40 steel pipework.

FluidFlow Designer Handbook

Page 51

Figure 5.3.1: Changing Quality Water System.

Step 1: The first step is to lay out the model as per Figure 5.3.1. Place two Known or
Assigned Pressure nodes (available from the Boundaries tab) on the flowsheet to
represent the system inlet and outlet. Select Steel Pipe or Duct from the Pipes tab and
develop the model connectivity as shown.
Lets add the control valve. Select the Controllers tab from the Component Palette and
select the Pressure Control Valve icon (Figure 5.3.2).

Figure 5.3.2: Pressure Control Valve.

Insert the element into the pipe as shown in Figure 5.3.1.


Step 2: Now we have completed the model connectivity, we can begin to edit the default
design input information.
The data-entry for the main inlet node (node 1) should appear as per Figure 5.3.3.

Figure 5.3.3: System Inlet Data-Entry.

The data-entry for the outlet boundary node shall be based on the default data, i.e. 1
ATM Stagnation Pressure etc. We therefore dont need to edit the design input data this
node.
Now we can consider the pipes. We need to define the lengths as shown in Figure 5.3.1
and described in Table 5.3.1 using the Input Inspector.

FluidFlow Designer Handbook

Page 52

Table 5.3.1: Pipe Lengths


Pipe User
Number

Pipe
Length (M)

Nominal
Size

Pipe User
Number

Pipe
Length (M)

Nominal
Size

-2

10.0

2 Inch

-1

10.0

2 Inch

Now we need to consider node elevations. This model doesnt include any elevation
changes and as such, we can retain the default value of 0 M for each node.
The final data-entry step is for the pressure control valve node (Figure 5.3.4).

Figure 5.3.4: Data Entry - Pressure Control Valve.

Step 3: Calculate the model using the Calculate button located at the top of the
flowsheet. The model solves without any warnings.
If we view the calculated results for the pipe node connected to the valve inlet, we can
see the fluid is in liquid phase and the software has applied the Moody correlation. If we
view the results for the pipe node connected to the valve outlet, we can see the fluid is
in two-phase and the software has applied the Friedel correlation.
In this case, the hot water enters the valve at 120oC and drops 82 kPa across the valve.
This reduces the pressure to below the saturation pressure for water and some of the
hot water vaporises. The vapor quality (wt fraction of steam) leaving the control valve is
0.0287. As the two-phase mixture flows down the pipe, the pressure reduces further and
additional liquid flashes. The final vapor quality leaving the system is 0.0385.

FluidFlow Designer Handbook

Page 53

6 Non-Newtonian Non-Settling Slurry Flow


FluidFlow includes the following non-Newtonian viscosity correlations; Power Law,
Herschel Bulkley, Bingham Plastic & Casson. Viscosity can be defined using two methods.
We can Directly Define Constants or enter a table of Shear Stress vs Shear Rate. You
can select the option which is more applicable based on the rheology data you have.
When we enter the table of values for Shear Stress vs Shear Rate, we can check the
validity of each of the four correlations as the software automatically fits the curve to the
co-ordinates defined. You can then clearly see which option represents the most
accurate curve-fit.
6.1

Non-Newtonian Design Exercise 1

Calculate the pressure gradient due to friction along a 1.0 M long 5.7 cm diameter pipe
with a chalk slurry flow rate of 2.23 x 10-3 m3/s into the pipeline. The discharge pressure
shall be 1 atm. The fluid viscosity data has been provided as a table of shear rate vs
shear strain (Table 6.1.1). The fluid is described as a Power Law fluid and has a yield
stress of 0.04 Pa and the fluid density is given as 1427 kg/m 3.
Table 6.1.1: Fluid Viscosity Data.
Shear Rate
(s-1)
1
10
40
100

Shear Stress
(Pa)
0.04
0.18
0.4
0.8

Step 1: The first step is to add the new fluid to the fluids database. Select; Database |
Fluids | Add. We will now be presented with a dialogue box asking us to give our new
fluid a unique name. Enter the name power law example and select OK. A new dialogue
will appear titled Fluid Editor (Figure 6.1.1). Select Non Newtonian Liquid as the Fluid
Type on the top right hand corner. You should now have a dialogue which matches that
shown in Figure 6.1.1.

Figure 6.1.1: Fluid Editor.

FluidFlow Designer Handbook

Page 54

We can see that the physical property data we need to define in order to model the new
fluid in the system includes, density, specific heat, thermal conductivity, viscosity and
vapor pressure. However, we may not have all of this information for the fluid. This can
be overcome as outlined below.
The two key physical property parameters we are interested in with non-Newtonian flow
is density and viscosity. Lets firstly consider density.
Fluid density can be entered either as a Fixed Value or as a Table, defining density
versus temperature. In this design case, we can select Fixed Value for the Density
Definition and enter a Fixed Density of 1427 kg/m3. Your data-entry for density should
appear as shown in Figure 6.1.2.

Figure 6.1.2: Fluid Density.

Lets now consider viscosity. Select the field titled Liquid Viscosity Definition on the Fluid
Editor. A new dialogue will appear titled Physical Property Editor Liquid Viscosity.
Viscosity can be defined using two methods. We can Directly Define Constants or enter a
Table of Shear Stress vs Shear Rate. You can select the option which is more applicable
to the rheology data you have. In this case, we will select Shear Stress vs Shear Rate as
the Viscosity Definition based on the data provided.
Select the field titled Shear stress-Shear rate to open a new dialogue titled Curve Fit.
Firstly we must set the Curve Fit Type to Power Law and enter the Yield Stress (Pa), in
this case 0.04.
Now we can enter the relationship for Shear stress-Shear rate as per Table 6.1.1. The
final data entry for viscosity should appear as per Figure 6.1.3.

FluidFlow Designer Handbook

Page 55

Figure 6.1.3: Fluid Viscosity.

When complete, select OK on the Curve Fit dialogue and OK on the Physical Property
Editor Liquid Viscosity dialogue. This completes the viscosity data-entry.
Now all that remains is specific heat, thermal conductivity and vapor pressure.
Specific heat and thermal conductivity are properties which are only used if we are
carrying out heat transfer analysis and in designing slurry pipelines, it is more often the
case that a heat transfer calculation is not required. Hence thermodynamic properties
are rarely available.
If the heat transfer calculation is not required, then it is recommended that the default
values (those for water) are accepted. If the intention is to perform heat transfer
calculations then this data must be entered correctly.
With regard to vapour pressure, again its unlikely that specific data will be available and
so, FluidFlow provides the option of simply selecting the pre-set values for water.
Remember, vapour pressure does not contribute to friction loss and is only important
where system pressure falls below vapour pressure.
We have now defined all the physical property parameters for the fluid. You should note
that the Liquid light bulb icon on the Fluid Editor dialogue will illuminate when the
data-entry is complete (Figure 6.1.4). Note, if the light bulb icon is not illuminated, it
means we have not fully defined the fluid and as such, we will not be in a position to
successfully model the fluid in a system.

FluidFlow Designer Handbook

Page 56

Figure 6.1.4: Fluid Editor.

We can now set about developing our model on the flowsheet.


Step 2: Since we know the design flow rate for the system, place a Known or Assigned
Flow node (available from the Boundaries tab) on the flowsheet to represent the system
inlet. Then, place a Known or Assigned Pressure node (available from the Boundaries
tab) on the flowsheet to represent the system outlet.
Select Steel Pipe or Duct from the Pipes tab on the Component Palette and place the
mouse selector directly over the Known or Assigned Flow node. Left mouse-click on this
inlet boundary to connect the pipe. Then, left mouse-click directly over the Known or
Assigned Pressure node to complete the connectivity. The model connectivity should now
be complete and appear as set out in Figure 6.1.5.

Figure 6.1.5: Base Model.

Step 3: Now we have completed the model connectivity, we can begin to edit the default
design input information.
The design flow rate for the system is given as 2.23 x 10-3 m3/s (0.00223 m3/s). We
can leave the fluid inlet temperature as 15 oC as this will not have an effect on our
results I this case. The data-entry for the main inlet node (node 1) should now appear as
per Figure 6.1.6.

FluidFlow Designer Handbook

Page 57

Figure 6.1.6: Inlet Boundary Data Entry.

The data-entry for the main outlet should appear as per Figure 6.1.7.

Figure 6.1.7: Outlet Boundary Data Entry.

Now we have completed the data-entry for our boundaries, the final step is to define the
properties of the pipe. We can therefore set the pipe diameter to 5.7 cm (0.057 m) with
a length of 1.0 M. The data-entry for the pipe should appear as per Figure 6.1.8.

FluidFlow Designer Handbook

Page 58

Figure 6.1.8: Pipeline Data Entry.

Step 4: Calculate the model using the Calculate button located at the top of the
flowsheet. The model solves without any warnings.
We can see for the results in the pipe that FluidFlow has estimated the pressure loss to
be 223.3 Pa. The Pressure Gradient is also calculated to be 223.3 Pa/m and since the
pipe is 1.0 m in length, this matches the overall pressure loss in the line. We can see
that the Loss Correlation is Power Law and the fluid phase state is described as NonNewtonian. The viscosity of the fluid is calculated along with the density, wall shear
stress and fluid shear rate. The results are outlined in Figure 6.1.9.
Note, the calculated result of 223 Pa compares well with the test data for this line as the
test indicated a pressure loss of circa. 215 Pa.

FluidFlow Designer Handbook

Page 59

Figure 6.1.9: Pipe -1 Calculated Results.

FluidFlow Designer Handbook

Page 60

7 Settling Slurry Flow


FluidFlow includes five pressure loss correlations for modeling settling slurry flow and
three correlations for determining maximum deposition velocity. Users can assign any of
these correlations to a slurry system design.
Lets firstly consider the pressure loss correlations.
Durand: The method used in the Slurry module is more properly called the DurandCondolios-Worster correlation. The Durand method uses the d50 particle size only. Size
distribution data entry is not used in the calculation.
WASC: This is the default calculation method used by FluidFlow. This method uses the
d50 & d85 particle size. Size distribution data entry is not used in the calculation.
WASP: This method is an expansion/refinement of the Durand method using size
distribution data to define stratified and homogenous concentration layers. The friction
loss of each layer is then calculated using slurry rheology and the Durand correlation.
Calculated pressure losses of each layer are summed to provide a total pressure loss in
the pipe.
Four-Component Model: This modeling approach considers the slurry to be made up of
four component parts; 1) a carrier fluid (typically water), 2) pseudo-homogeneous
mixture, 3) heterogeneous solids and 4) fully stratified solids. The friction loss of each
layer is then calculated and summed to provide a total pressure loss in the pipe.
Liu Dezhong: The method proposed by Liu Dezhong is a two-component method and
has been successfully used in China for the design of short distance (less than 4 km)
slurry pipelines with broadly graded size distribution The smaller particles are considered
to form a pseudo-homogeneous carrier fluid. Depending on the fluids overall particle
size distribution and concentration it has either Newtonian or non-Newtonian Bingham
Plastic properties. The larger particles are assumed as a heterogenous suspension.
We above describes in brief, the five different pressure loss correlations available in
FluidFlow.
Now lets consider the three correlations for determining maximum deposition velocity
(Vsm);
Vsm Option 1: WASC Generalized Relationship.
Vsm Option 2: As a Function of particle size.
Vsm Option 3: Oroskar & Turian.
7.1

Calculation Settings Settling Slurry Flow.

Before we consider modeling our system, we need to give careful consideration to the
Calculation Settings we wish to apply to the model. To review the Calculation Settings
select; Options | Calculation | Non-Newtonian & Slurry (Figure 7.1.1).

FluidFlow Designer Handbook

Page 61

Figure 7.1.1: FluidFlow Slurry Calculation Settings.

We can change settings by selecting the drop-down menu options as shown in Figure
7.1.1.
7.2

Settling Slurry Design Exercise 1

Coal is to be transported through a pipe with a length of 10 ft and an I.D. of 17.3 inches
and a solids concentration (Cvd) of 25%. The design flow rate is 0.471 m3/s and the coal
has the following properties;
Solids Density: 1400 kg/m3.
Bulk Density: 840 kg/m3.
Solid Sliding Bed Coefficient: 0.44.
The particle sizes yield a d50 of 2.0mm and d85 of 2.8mm. Calculate the maximum limit
of deposition velocity (Vsm).
Note, the solids data is already included in the FluidFlow database. This can be accessed
at; Database | Solids | Coal (WASC). We therefore dont need to define a new solid in
the database.
Step 1: The first thing we need to do is consider the Calculation Settings. In this case,
we know the d50 and d85 values and as such, we will select Wilson Addie Sellgren Clift
(WASC) pressure loss correlation.
In this example, we will also select the WASC generalized relationship to determine the
Vsm deposition velocity.
We can now set about developing our model on the flowsheet.
Step 2: Since we know the design flow rate for the system, place a Known or Assigned
Flow node (available from the Boundaries tab) on the flowsheet to represent the system
inlet. We are going to terminate this pipe with an open pipe node, i.e. discharging at

FluidFlow Designer Handbook

Page 62

atmospheric pressure. We can therefore select Steel Pipe or Duct from the Pipes tab on
the Component Palette and place the mouse selector directly over the Known or
Assigned Flow node. Left mouse-click on this inlet boundary to connect the pipe.
Then move the mouse selector across to the right hand side and left mouse click in the
position where we wish to terminate the pipe. You will notice that the pipe has
automatically terminated with an open pipe node.
The model connectivity should now be complete and appear as set out in Figure 7.1.2.

Figure 7.1.2: Base Model.

Step 3: Now we have completed the model connectivity, we can begin to edit the default
design input information.
The design flow rate for the system is given as 0.471 m3/s, the concentration of solids
by volume is 25%, the d50 and d85 are 2 and 2.8 mm respectively and the solid to be
transported is of course, coal. We need to assign a carrier fluid to the slurry, in this case
we will use water. The data-entry for the inlet boundary node should appear as per
Figure 7.1.3.

Figure 7.1.3: Inlet Boundary Data Entry.

We shall retain the default data for the open pipe outlet. Now lets edit the pipe data.

FluidFlow Designer Handbook

Page 63

Figure 7.1.4: Pipe Data Entry.

Step 4: Calculate the model using the Calculate button located at the top of the
flowsheet. The model solves without any warnings. Figure 7.1.5 provides an overview of
the results.

Figure 7.1.5: Pipe -1 Calculated Results.

FluidFlow Designer Handbook

Page 64

We can see that FluidFlow has estimated the pressure loss in the pipe to be 0.28 ft fluid
and the velocity in the line is calculated to be 10.19 ft/s. We can also see that the
software has established the composition mass % of the liquid and solids, i.e. 68.2%
liquid and 31.8% solids.
The Cvd deposition velocity at the defined concentration (25% by volume) is given as
2.97 ft/s and the deposition velocity (Vsm) is given as 6.33 ft/s. This is the critical
deposition velocity for the plant. Furthermore, if we select the Chart tab, we can view
the slurry pipe resistance curve and the duty point on the curve. Figure 7.1.6 illustrates
the system resistance curve for pipe node -1.

Figure 7.1.6: Pipe -1 Pipe Resistance Curve.

FluidFlow also allows us to determine the solids delivered. We can check this data by
viewing the results for a boundary node. Figure 7.1.7 shows the results for the open pipe
boundary node (system outlet).

FluidFlow Designer Handbook

Page 65

Figure 7.1.7: Open Pipe Boundary.

One of the unique features of FluidFlow is that, although we have only specified the d50
and d85 in this case, the software automatically develops a Rosin-Rammler particle size
distribution curve which means, we can now apply any of the five correlations to the
model.
To view the Rosin-Rammler curve, select a known pressure or in this case, know flow
boundary node and select the Chart tab. Figure 7.1.8 shows a typical Rosin-Rammler
curve as developed by FluidFlow.

FluidFlow Designer Handbook

Page 66

Figure 7.1.8: Rosin-Rammler Curve.

FluidFlow Designer Handbook

Page 67

8 Auto-Equipment Sizing
FluidFlow includes a powerful auto-size feature which allows engineers to automatically
size a range of elements such as pipes, centrifugal pumps, fans, compressors, PD
pumps, orifice plates, nozzles, pressure and flow control valves. Pressure relief valves
and bursting disks can also be auto-sized to API & ISO standards for liquids, gases,
steam and two-phase flow systems.
8.1

Auto-Equipment Sizing Design Exercise 1

This example involves designing a cooling water distribution system to a bank of heat
exchangers where we shall use orifice plates to balance the flow distribution. We shall
also use the auto sizing functions to develop the system design and size the pipes, pump
and orifice plates.
Problem Statement:
It is desired to provide a balanced cooling water flow to four shell and tube heat
exchangers HE1, HE2, HE3 and HE4. The size of the heat exchangers has already been
determined from the process requirement and is summarized in Table 1.
Table 1: Heat Exchanger Data.
Item

Heat Load
(kW)

Tube Length
(M)

HE1
HE2
HE3
HE4

370
250
370
250

4
4
4
4

Tube
Diameter
(mm)
20
20
20
20

Number of
Tubes
20
20
20
20

The cooling water is to flow through the heat exchangers and the design system inlet
temperature will be 15C. The design temperature rise of the cooling water across each
heat exchanger is 30C. The elevation of the all elements in this model is zero. The
design duty pressure rise for this system is also known, 2.5 bar.
Building the model in the FluidFlow flowsheet:
1. Place two known pressure boundary nodes on the flow sheet.
2. Using the steel pipe element, connect the known pressure boundary nodes together
as per Figure 1 below.
3. Add the branch pipe connections, ensuring the branch at each tee junction is assigned
correctly.
4. Insert the heat exchangers into each branch line.
5. Insert thin orifice plates into the branch pipe connection serving each heat exchanger.
When complete, the model should appear as per Figure 8.1.1.
The basic model connectivity should appear as set out in Figure 1.

FluidFlow Designer Handbook

Page 68

Figure 8.1.1: Base Model.

Each element placed on the flowsheet is provided with default data which the engineer
can easily edit based on known design parameters. In this case, we will define the pipe
lengths as set out in Table 2. Note, we will accept the default data provided by FluidFlow
for the boundary nodes.
Table 2: Pipe Length Data.
Pipe User Number

Pipe Length (M)

Pipe User Number

Pipe Length (M)

-19
-14
-12
-20
-15
-9
-21
-16
-6
-22
-17

5
5
5
5
5
5
5
5
5
5
5

-2
-4
-5
-7
-8
-10
-11
-3
-18
-1

5
5
5
2.5
2.5
1.25
1.25
1.25
1.25
1

Select all the heat exchangers at once by holding the SHIFT key and left mouse-clicking
on each. All heat exchangers should now be highlighted on the flowsheet. From the
Input tab of the Data Palette, set the Heat Loss Model to Fixed Transfer Rate, the heat
transfer direction to Into the Network and the Heat Transfer Unit to kW. We have now
set all common parameters for the heat exchangers in one step.
The next step is to define the heat load for each heat exchanger (see Table 1).
The design pump pressure rise is 2.5 bar. We can therefore set the centrifugal pump to
Automatically Size from the Input Tab on the Data Palette. In doing so, we have two
sizing options available; Size for Flow and Size For Pressure Rise. Select Size For
Pressure
Rise
and
defined
the
Design
Pressure
Change
as
2.5
bar.

FluidFlow Designer Handbook

Page 69

Using the data available for the heat exchangers, we can determine the design mass
flow rate from the heat balance (Q = m x c x T). The heat transferred to the cooling
water will therefore be:
Heat Transferred (W) = mass flow (kg/s) x specific heat capacity (J/kg) x temperature
rise (C)
The specific heat of water at 30C is approx 4154 J/kg, so from Table 1 we see that the
mass flow needed to HE1 will be 370000 / (4154 x 30) = 2.969 kg/s. Summarizing in
Table 3.
Table 3: Mass Flow Rates.
Heat Exchanger
HE1
HE2
HE3
HE4
Total

Mass Flow (kg/s)


2.969
2.006
2.969
2.006
9.95 kg/s

Since we can auto-size our components, we can define the design flow rate at each
orifice plate by setting the Automatically Size option on the Input tab of the Data Palette
to On. We now have two sizing models to choose from, Size for Flow and Size for
Pressure Loss. As we know the flow rate, select Size for Flow. The next step is to enter
the mass flow rates noted in Table 3 for each orifice plate.
The Sizing Model for pipes is Economic Velocity by default. This means that FluidFlow will
determine the Exact Economic Size pipe diameter based on the calculated Economic
Velocity. This velocity is a function of the fluid physical properties, the pipe materials,
various capital and installation costs and the operating hours/year. This value is
calculated from the Generaux equation and the calculation uses the values and constants
stored in the pipe sizing database. Economic velocity is changing (generally decreasing)
with time, particularly as energy costs have increased rapidly in recent times. Flite
Software keeps these values up to date, which is one of the many reasons you should
keep your software current. Economic velocity is meant to be a guide for pipe sizing it is
NOT a strict criteria for sizing pipes. For example you would not use this value to size
pipes where two phase flow is present, or where plant operation is intermittent, or where
materials can degrade at high velocities, or for Non-Newtonian flows.
We wish to develop an efficient system design and as such, we are going to retain the
Economic Velocity sizing model.
We are now in a position to calculate the model. The solved system should appear as set
out in Figure 8.1.2.

FluidFlow Designer Handbook

Page 70

Figure 8.1.2: Solved Model Default 2 Inch Pipes.

The flow distribution has been shown and if we view the results for any of the four heat
exchangers, we can see that the inlet temperature is 15C and the outlet temperature is
45C (based on our design 30C temperature rise).
Note, we also have three warning messages indicating high velocities in the pipelines
highlighted in RED.
A quick check on the results for each of the pipes with a high velocity warning indicates
velocities in the range of 4.5m/s which is considered high. We therefore need to review
the pipe diameter. The diameter of each of these pipes is the default value of 2 inch
which is 52.5mm. FluidFlow has determined an economic pipe size of approx. 101mm for
each of these three pipes. We therefore need to select the next closest standard size
match. Lets try a 4 inch schedule 40 pipe.
You can multi-select the three pipes by holding the SHIFT key and left mouse-clicking on
each pipe. From the Input tab on the Data Palette, access the pipes database and
change the pipe to 4 inch schedule 40 pipe. Press Calculate to refresh the results for the
system.
If we view the results for the orifice plates, we can see that FluidFlow has automatically
determined the K value and the size of orifice required to provide the desired mass flow
rate. The pump duty has also been established for us as 9.95 kg/s @ 2.5 bar (26 m
fluid).
The warnings have also been corrected and as such, it can be considered that the
system is now a relatively efficient design.
Based on the data entry, FluidFlow has therefore automatically sized the pipework, pump
and orifice plates for us, thus simplifying the design process and reducing design time
considerably.
The final design should appear as set out in Figure 8.1.3.

FluidFlow Designer Handbook

Page 71

Figure 8.1.3: Solved Model Updated Pipe Diameters.

Design Note;
When using the auto size function, its important not to over-constrain the model as this
could lead to model convergence difficulties. For instance, in this example, we could
have set the sizing model for the pump to Size for Flow. As we had effectively already
defined the total flow in the system by defining the flow rate at each orifice plate, we
would have duplicated the flow in the system. It is best to avoid duplicating design
parameters when developing your model.

FluidFlow Designer Handbook

Page 72

9 FluidFlow FAQs
How has FluidFlow been verified ?
The results generated by FluidFlow for liquids, gases, two-phase fluids and slurries are
rigorously tested and verified against published data and real-world operating systems
on a continuous basis. An extensive library of Quality Assurance test models are also
installed with the software.
As FluidFlow is continuously undergoing development, each new version of the software
is benchmarked using the above procedures.
FluidFlow has been used successfully in industry since it was first launched 1984. The
software has undergone extensive development since first launched ensuring the product
is up to date, includes the very latest solution technology and offers engineers a fast and
effective design simulation tool.
Quality Assurance is an integral part of our business ethic. From our software design
approach through to our released product, FluidFlow is developed to the highest quality
and standard.
Flite Software Ltd is an ISO9001:2008 registered company.
Can FluidFlow be used to model heat transfer in piping systems ?
Yes. All FluidFlow modules are provided with heat transfer functionality - As Standard.
This includes the ability to perform pipe heat loss calculations whilst taking into account
the effect of local wind speed, surface emissivity & ambient temperature.
A library of pipe insulation materials is provided with the software As Standard and you
can select the required thickness for each pipe. Convection, conduction and radiation
losses are calculated automatically. This means FluidFlow can be used to quickly
optimize energy use by selecting the economic insulation thickness.
When performing heat loss calculations, Engineers can choose to enter a U value or allow
the software calculate this parameter.
The software also allows engineers to analyse the effect of a fixed temperature change
or energy transfer rate across a pipe or fitting. FluidFlow completes an energy balance
throughout all piping systems.
FluidFlow can model shell and tube exchangers, plate heat exchangers, coils and
autoclaves.

FluidFlow Designer Handbook

Page 73

Can FluidFlow be used to model a non-Newtonian fluid ?


Yes. The Slurry module allows you to choose from the following non-Newtonian fluid
models;
Bingham Plastic
Herschel Bulkley
Power Law
Casson
Engineers can create a new non-Newtonian fluid by either entering the shear rate vs
shear stress relationship or directly define the fluid constants. This data is readily
available from fluid rheology data.
Can FluidFlow be used to model a settling slurry ?
Yes. FluidFlow includes five pressure loss correlations for modelling settling slurry piping
systems. Unique to FluidFlow is the ability to model slurries which exhibit a combination
of settling and non-settling slurry flow behaviour. This means Engineers dont have to
make the difficult choice of modelling a slurry as either settling or non-settling when in
fact it may exhibit properties of both flow regimes.
Users can choose from a total of five correlations when modelling settling slurry systems.
When developing the model, the software will enunciate warning messages to assist the
engineer in developing an efficient system design. This includes messages identifying the
risk of saltation or, pipe blockage.
FluidFlow inlcudes three options for analysing the pump performance derating.
Can FluidFlow be used to model Fire Protection Systems ?
Yes. FluidFlow includes a proprietary fire sprinkler and hydrant node and includes a
comprehensive database of components - As Standard. Additional sprinklers can be
added to the database by either entering a single nominal K value or entering the flow vs
pressure loss relationship and additional hydrants can also be added by either entering a
single K value or a pressure loss relationship of % open vs Kv/Cv.
Note, when defining either of the above items using a pressure loss relationship,
FluidFlow automatically generates the curve-fit.
Can I create a Template File in FluidFlow ?
Yes. Users can generate template files such as pump stations and valve stations from
v3.3. These templates can be stored and inserted into any model in the future. This
promotes rapid model development.
Do I have to enter the model into each module separately ?
No. The software uses a single user-interface meaning any model can be calculated
using any of the Modules available.
Can FluidFlow be used to model Pressure Relief Valves & Bursting Disks?

FluidFlow Designer Handbook

Page 74

Yes. From version 3.3 onwards, users can automatically size relief valves and bursting
disks for liquid, gas, steam and two-phase systems to both API & ISO standards. When
using the API method, FluidFlow also suggests the most appropriate standard API size
for your consideration.
The software also allows you to model specific manufacturers relief valves and is
provided with a library of relief valve models - As Standard. Engineers can expand the
library of relief valves by adding new models as and when required.
Can I model closed-loop systems ?
Yes. FluidFlow has been used successfully by our customers to model closed-loop piping
systems such as sea water cooling systems. When modeling this system type, the
software takes into account that the pressure, velocity and elevation of the inlet and
outlet are identical and therefore, the changes in static, velocity and elevation pressures
are zero.
Can I model pipe inclination/elevation changes ?
Yes. Pipe inclination is determined by the software based on the elevation data entered
for each junction on the Input Inspector. This applies to liquids, gases, two-phase fluids
and slurries.
Can I model non-standard fittings ?
Yes. FluidFlow includes a proprietary component for modeling the pressure loss
relationship of any non-standard pipe/duct fitting.
Can I close-off or isolate sections of a model ?
Yes. Simply select the relevant pipes and fittings in the model and set the Status to Off
or Closed from the Input Inspector. When you recalculate your model, you will notice
that flow does not occur in these sections of the model.
Can I add pumps to the database ?
Yes. The software is provided with a library of Centrifugal, PD and Rotating PD Pumps.
Engineers can expand the library by adding new pump models as and when required. It
should be noted that, when adding a new pump to the database, you are only required
to do so once. The pump will then be stored in the database and shall be available for all
future design/modeling projects.
Can I apply pump affinity laws ?
Yes. FluidFlow allows you to model the effect of changing the pump operating speed or
impeller diameter. The software automatically applies the affinity laws and will determine
the effect on duty pressure rise, efficiency, power requirement and NPSHr.
This is an extremely powerful tool and is used frequently by users to optimise the
operating performance and energy consumption of centrifugal pumps.

FluidFlow Designer Handbook

Page 75

Can I add fans or compressors to the database ?


Yes. The software is provided with a library of fans and compressors. Engineers can
expand the library by adding new models as and when required. It should be noted that,
when adding a new fan or compressor to the database, you are only required to do so
once. The component will then be stored in the database and shall be available for all
future design/modeling projects.
Can I model control valves ?
Yes. FluidFlow is provided with a library of pressure, flow and differential pressure
control valves. Users have the option of expanding the library by adding new valves
when required. The software will automatically determine the Cv/Kv and corresponding
valve position (% open). Furthermore, the software will enunciate a warning message if
the valve position is outside the allowable range of good practice procedures.
The flow rate, system pressure, velocity etc is automatically determined by the software
for all control valves.
Can I model the effect of partially closing isolating/throttling valves ?
Yes. Users can enter a % open on the Input Inspector for all manual valves. FluidFlow
will then determine the corresponding K value and associated pressure loss for the valve.
When changing the % opening of the valve, the software will determine the effect on
flow rate, pressure, velocity etc.
Can I model PD Pumps ?
Yes. The software is provided with a library of PD Pumps and Rotating PD Pumps.
Engineers can expand the library by adding new pump models as and when required. It
should be noted that, when adding a new pump to the database, you are only required
to do so once. The pump will then be stored in the database and shall be available for all
future design/modeling projects.
Can I plot composite pump curves ?
Yes. Composite pump capacity curves can be developed for pumps installed in both
series and parallel. This provides a powerful method of communicating your system
design and pump performance data.
Can I plot Energy & Hydraulic Grade Lines ?
Yes. Energy & Hydraulic Grade Lines can be plotted for your system. This graph plot
provides a useful representation of the level of energy in the system. This also helps
engineers quickly identify any potential trouble-spots.
This tool has been used effectively and successfully to model and troubleshoot piping
systems transporting fluid/slurry over considerable distances using multiple centrifugal
pumps in series. The graph plot clearly identified regions of low pressure and enabled
the engineering teams to optimise the positioning of the pumps and the individual pump
performance.

FluidFlow Designer Handbook

Page 76

Can I model ductwork ?


Yes. Simply select the duct on the flowsheet and set the geometry of the duct on the
Input Inspector to Rectangular/Square. Users can then enter the height and width of the
ductwork.
Can FluidFlow detect choked flow conditions ?
Yes. FluidFlow will detect sonic choking and endpoint choking, highlight the node on the
flowsheet where this has occurred and enunciate a warning to this effect.

Contact us at:
support@fluidflowinfo.com
Flite Software NI Ltd
Block E
Balliniska Business Park
Springtown Road
Derry
Northern Ireland
BT48 0LY
T: +44 2871 279 227
F: +44 2871 279 806
www.fluidflowinfo.com

FluidFlow Designer Handbook

Page 77