Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CP1290 12V 9ah (20hr)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

CP1290

12V 9Ah(20hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead

ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

Performance Characteristics

General Features

Absorbent Glass Mat (AGM) technology


for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.

Dimensions and Weight


Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

151 / 5.94
65 / 2.56
94 / 3.70
100 / 3.94
2.8 / 6.17

Nominal Voltage
12V
Number of cell
6
Design Life
3~5 years
o
o
Nominal Capacity 77 F(25 C)
20 hour rate (0.45A, 10.5V)
9Ah
10 hour rate (0.82A, 10.5V)
8.2Ah
5 hour rate (1.54A, 10.5V)
7.7Ah
1 hour rate (5.8A, 9.6V)
5.8Ah
Internal Resistance
18mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
135A(5s)
Max. Discharge Current 77 F(25 C)
Short Circuit Current

450A

Charge Methods: Constant Voltage Charge


Cycle use
Maximum charging current
Temperature compensation
Standby use
Temperature compensation

77oF(25oC)
14.5-14.9V
3.6A
-30mV/oC
13.6-13.8V
-20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min 10min 15min 30min


33.0
32.1
30.9
30.3
29.6

24.2
23.6
22.9
22.1
21.0

17.0
16.5
16.1
14.6
13.9

9.90
9.79
9.36
8.91
8.45

1h

3h

5h

10h

20h

5.80
5.75
5.71
5.66
5.51

2.33
2.29
2.25
2.20
2.14

1.60
1.56
1.55
1.54
1.53

0.87
0.86
0.84
0.82
0.82

0.47
0.46
0.46
0.45
0.44

3h

5h

Discharge Constant Power (Watts at 77oF25oC)


End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min 10min 15min 30min 45min


71.7
68.3
64.8
61.4
58.0

44.8
44.3
42.9
41.1
39.2

33.6
33.1
31.1
30.2
28.4

19.6
19.1
18.5
17.6
16.6

1h

2h

14.5 11.5 6.30 4.34 3.10


14.2 11.2 6.23 4.29 3.04
13.7 11 6.08 4.20 2.98
12.9 10.7 5.94 4.08 2.92
12.2 10.4 5.77 3.92 2.85

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.

page1 of 2

www.vision-batt.com

13.0

12V9Ah

Constant voltage charging


characteristic (0.25CA,25 oC)

(%) (XCA) (V)


140

12.0

Voltage(v)

Voltage

Discharge characteristic (25 OC)

Current

Charged
Volume

CP1290

120

0.25

100

0.20

11.0
10.0

80

0.15
0.10

40

8.0

20

0.05

5
min

20 30

10

60

2 3

5
h

10

20 30

14.0

Charge Voltage

12.0
11.0

0 1

Charged Volume

13.0

60

9.0

15.0

Charging Current

10

12

14

16

18

20

Charging time (hours)

Discharge time

Relationship between
charging voltage and temperature

Self-discharge characteristic
110
100

Cycl

15.0

e Us

Capacity(%)

Voltage(V)

15.6

14.4
S ta n d

13.8

by Use

90
80
70
60

13.2

50

-10

10
20
30
40
o
Ambient temperature( C)

50

40

60

8
10
12
14
Storage time: months

16

18

20

Cycle service life in relation to


depth of discharge

Life characteristics of Standby use


120

120
100
Capacity(%)

Capacity(%)

100

80

60

Testing conditions:floating voltage:2.27 to 2.30V Cell


o
o
ambient temperature: 25 C(77 F)

80
60

40

40

20

20

2
Life(year)

30% Depth of discharge

100% D.O.D. 50% D.O.D.

200

400

600

800

1000

1200

1400

Number of cycles(cycles)

Temperature effects on float life

Temperature effects on capacity

10

120

Capacity (%)

Life(years)

100

2.30V Cell
1

C
0 .0 5
0 .1 C
C
2
.
0

80
60

1 .0 C
2 .0 C

40

3 .0 C

20
0.1

10

20

30

40

50

0
-20

60

-10

10

20

30

40

Temperature( C)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000

MH25860

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9)

Page 2 of 2

50( C)

You might also like