A quench tower cools gas entering a tail gas amine unit but also protects the
amine against SO2 breakthrough
Ralph Weiland, Clayton Jones and Nathan Hatcher Optimized Gas Treating, Inc

ail gas from most sulphur recovery units


(SRU) is routed to a reduction quench
amine tail gas treating unit (TGTU). A
hydrogenation reactor first converts (reduces)
residual sulphur species such as SO2, COS, CS2,
and elemental sulphur into H2S for eventual
recycling back to the SRU. Before its sulphur
content is recovered, however, the hot gas from
the hydrogenation reactor is quenched to make
it cool enough for feeding to the TGTU amine
system. Here, the hydrogen sulphide content is
captured by a H2S selective solvent, usually
N-methyldiethanolamine (MDEA). This article
focuses on the quench tower, which tends to
receive little or no engineering attention, despite
its very important role in the overall sulphur
recovery process.
The primary purpose of the quench tower is to
cool the hot gas (500600F, 260-315C) from
the hydrogenation reactor to around 100F
(38C) by direct contact with cooling water. In
addition to lowering the temperature, generally
about 85% of the water content is removed as
well. This water would otherwise need to be
purged from the amine system downstream to
maintain amine strength. A sometimes poorly
appreciated secondary role of the quench tower is
to afford some measure of protection of the TGTU
from harmful contaminants that would otherwise
enter with the quenched tail gas. In particular,
any small amounts of ammonia and SO2 in the
gas can be removed in the quench tower. Unless
the amine is protected, over a period of time,
even small levels of SO2 contamination can generate heat stable salts and other more reactive
amine degradation products of the MDEA solvent,
harming the selectivity for hydrogen sulphide.

www.digitalrefining.com/article/1001271

Trays are rarely used any more in quench


towers because of the fast volume decrease that
accompanies the rapid drop in temperature,
which has a tendency to buckle trays. Today,
quench towers are almost always packed, and
since high efficiency is not needed to achieve
adequate cooling, large diameter random packings are quite suitable. As will be seen later,
although cooling itself occurs very rapidly,
water removal requires a little more extended
contact, and the removal of any ammonia or
sulphur dioxide requires even more contact
with the cooling water. In other words, very
little packed height is needed to achieve cooling, but quite a bit more is needed to remove
contaminants. Thus, accurate simulation of the
quench tower can benefit operations by predicting how much sulphur dioxide from an SO2
breakthrough will actually reach the TGTU
amine section, how much will be removed in
the quench water, and how much ammonia will
be captured as well.
How a quench tower performs in terms of
heat transfer and protection of the TGTU is
discussed in the context of a case study using
conditions from an operating refinery unit. In
particular, SO2 breakthroughs and controlling
these events using ammonia or caustic injection
are addressed.

Case study
For this study, the TGTU quench column and
quench water circuit shown in Figure 1 have
been isolated from the overall SRU-TGTU flowsheet The column contains 20 ft (6.1 m) of IMTP
50 random packing. The gas enters at 15 psia
(1.03 bara) and 555F (290C)1 with the compo-

Gas 2016 1

Component flows in quench feed

To amine
section


Flow,
Flow,

lbmol/h kmol/h
Water
307.1
139.3
Carbon dioxide
82.6
37.5
Hydrogen sulphide 8.3
3.76
Sulphur dioxide
Trace
Trace
Ammonia
0.051
0.023
Hydrogen
41.3
18.7
Carbon monoxide
0.3
0.136
Nitrogen
583.3
264.6
Total
1023 464

Tear
Quench
column
Quench
feed

Quench
cooler

Table 1

2
9

To quench
purge

Bleed

Distance from top of column,


feet

Figure 1 TGTU quench simulation flow sheet

300 bbl/h
450 bbl/h
683 bbl/h

10

15

20

100

200

300

400

500

600

Distance from top of column,


feet

Temperature, F
0

300 bbl/h
450 bbl/h
683 bbl/h

10

15

20

100

200

300

Water flow in gas, lbmol/h

Figure 2 Gas temperature and water flow profiles

nent molar flows shown in Table 1. The ammonia


concentration of 50 ppmv is not atypical for the
gas going to a quench column in a tail gas treating unit. For the case study the SO2 to NH3

2 Gas 2016

400

500

molar ratio was varied from 0.1


to 3.0. Quench water was maintained
at
93F
(33.9C).
Condensed water was drawn
from the circuit via Stream 7 at
whatever rate was necessary to
keep the circulating water flow
to the quench column constant
at 300, 450 or 683 bbl/h (209,
314, 476 std. USgpm or 47.5,
71.2, 108.1 std. m3/h).
More than the overall performance of the quench system, the
study (using the ProTreat mass
and heat transfer rate based
simulator) was done to expose
the inner workings of the
column itself, and how it might
handle various levels of SO2
breakthrough from the SRU. In
other words, when can the
quench column be expected to
protect the downstream amine
system from an SO2 breakthrough, what level of protection
can be provided, and what can
be done operationally to mitigate
a
higher
level
breakthrough? First, however,
how does the quench fulfill its
primary function of cooling the
gas?

Gas cooling
Figure 2a shows temperature profiles across the
column while Figure 2b shows the changing flow
rate of water in the gas. The parameter in these
plots is the circulation rate of the quench water.

www.digitalrefining.com/article/1001271

Ammonia and sulphur dioxide,


being alkaline and acidic respectively, react not just with water,
but strongly associate with each
other in the water phase:
! + ! ! + !!
!! ! + !!

! + ! !! + !

!! + !! !! !!

2!! + !! (!! )! !!

10

15

20

0.02

0.04

0.06

0.08

0.10

0.12

SO2 flow in gas, lbmol/h

Distance from top of column,


feet

NH3 and SO2 removal in the


quench column

Distance from top of column,


feet

As soon as the gas enters the


Insensitivity of quenched gas composition to quench water flow rate
column, it is immediately
quenched by about 400F.

Outlet gas
However, at the lowest quench
Inlet gas Quench water, 300 bbl/h
Quench water, 683 bbl/h
SO2, NH3, Temp, SO2, NH3, Temp, SO2, NH3,
water rate, much of the initial
ppmv
ppmv F ppmv
ppmv F ppmv
ppmv
cooling at the bottom of the
25
50
93.0
0.179
0.69
93.6
0.173
1.05
packing is by evaporation of
50
50
93.0
3.83
0.070
93.6
3.96
0.10
75 50 93.0 33.3 0.0086 93.6 35.1
0.023
water (that is, transpiration, or
100 50 93.0 66.0 0.0045 93.6 67.0
0.011
swamp cooling), and the gas
remains very high in water until
it approaches the upper half of Table 2
the bed where it meets cooler
water. Cooling is by sensible heat transfer as reactions above. Thus, if the SO2 to NH3 ratio in
well as by transpiration cooling. At low circula- the gas is less than one, the cooled gas can be
tion rates, much of the 20ft packed bed is expected to be virtually SO2 free. Conversely, if
necessary to cool the gas the heat transfer this ratio is greater than about one, the gas
process is not fast. None of this is obvious from phase should be ammonia free but will contain
inlet and outlet stream measurements, because whatever SO2 cannot dissolve physically in the
the outlet gas temperatures in these extreme quench water. If the gas has more SO2 than
cases differ by only a fraction of a degree. ammonia, the water will be acidic but if there is
Furthermore, as will become apparent, the outlet more ammonia than SO2 it will be alkaline. This
SO2 concentrations differ by at most 2 ppmv in a expected behaviour is why monitoring the pH of
total value of 65 ppmv. ProTreat
simulation shows that virtually
0
all ammonia is removed, but the
0.54
fraction
of
SO2
removed
1.00
depends strongly on the SO2 to
1.50
5
NH3 ratio in the inlet gas.
2.00

0.54
1.00
1.50
2.00

10

15

Ammonia is highly soluble in


water, whereas sulphur dioxide
20
is only sparingly soluble. Any
10-6
10-5
10-4
10-2
10-1
10-3
1
dissolved ammonia will tend to
NH3 flow in gas, lbmol/h
drag an equal amount of SO2
into the water phase with it Figure 3 Molar flow rate profiles in the gas with quench water flow at 300
through the aqueous acid base bbl/h with varying SO2 to NH3 ratio in feed gas

www.digitalrefining.com/article/1001271

Gas 2016 3

0.54
1.00
1.50
2.00

Distance from top of column,


feet

Distance from top of column,


feet

of the column remains fairly


steady until it falls through two
orders of magnitude in the top
half.
5
At high SO2 to NH3 ratios and
the lowest quench water rate,
10
SO2 first absorbs across the
lower end of the column, and
then strips across the middle
15
section, before absorbing again
in the top end. Ammonia
20
absorbs throughout the column
0
0.02
0.04
0.06
0.08
0.10
0.12
because of its high solubility.
SO2 flow in gas, lbmol/h
This has corrosion implications
0
because corrosion is exacer0.54
1.00
bated by high temperatures and
1.50
high levels of SO2 in the water.
5
2.00
The S-shaped SO2 profile is
again related to the complex
10
interaction between the temperature profile, the chemical
reactivity between the absorbing
15
species, and the high gas phase
water content, which begins to
20
fall off only in the upper part of
10-6
10-5
10-4
10-2
10-1
10-3
1
the quench tower. The decreasNH3 flow in gas, lbmol/h
ing water content results in
Figure 4 Molar flow rate profiles in the gas with quench water flow at 683
higher SO2 levels in the gas,
bbl/h with varying SO2 to NH3 ratio in feed gas
driving more SO2 into the
quench water.
quench tower pumparound water is a good
A level of 150 ppmv SO2 in the gas going to the
practice.
quench column is a fairly high value for an SO2
First, it is worth noting that the SO2 and to a breakthrough event. The pH profiles in the tower
lesser extent the NH3 concentrations predicted are revealing (see Figure 5). During a significant
to remain in the quenched gas are relatively SO2 breakthrough, the quench water can become
insensitive to the quench water flow rate (as long highly acidic with a pH well below four, but if
as this is high enough to leave the quenched gas the quench water rate is low pH is lowest in the
temperature relatively unaffected). Therefore, upper part of the column. This is caused by a
there are almost no external observations that high sulphurous acid level in the water there. If
would give any indication of behaviour inside the quench water rate is high, the pH will be
the quench tower. Table 2 shows these uniformly low throughout the column once
predictions.
steady state is achieved. Measuring pH in the
The most striking predictions of molar flow quench water circuit, either just before entry or
rate2 profiles of SO2 and ammonia are at the 300 after exiting from the quench tower, can be used
bbl/h quench water rate shown in Figure 3. to indicate when an SO2 breakthrough is occurProfiles at the highest quench water flow (683 ring. However, a measurement in this location
bbl/h) are shown in Figure 4 for comparison. may not reveal the true extent of the possible
When the SO2 and ammonia levels are equal in corrosion damage being done to the column
the inlet gas (at 300 bbl/h), th SO2 flow profile shell and the packing because the actual pH
through the quench column (blue line in Figure inside the column may be fully 1 to 1.25 units
3a) follows the temperature profile (blue line) in more acidic than indicated. SO2 breakthrough
Figure 2a. The ammonia profile in the lower half results in highly acidic quench water fully capa0

4 Gas 2016

www.digitalrefining.com/article/1001271

Mitigating an SO2 breakthrough

Distance from top of column,


feet

ble of dissolving mild steel and


even lower grades of stainless
steel such as Type 304. Type
316 will be more resistant
although probably not immune
from acid attack. The place in
the quench tower to look for
corrosion damage appears to
vary with the quench water flow
rate, but the upper half of the
quench tower seems to be most
susceptible to corrosion damage.

2
4
6
8
10
12
14
16
18
20
3.5

0.1
0.5
1.0
2.0
3.0

4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5
When an SO2 breakthrough
pH
from the SRU occurs, it is
important to:
Figure 5 pH Profile in the quench column at 300 bbl/h (solid lines) and
Detect the breakthrough,
Protect the quench tower and 683 bbl/d (dashed lines) quench water rate, SO2 to NH3 ratio as parameter,
its internals from rapid acidic and 100 ppmv SO2 in the gas. Parameter is SO2 to NH3 ratio in feed gas to
quench tower
corrosion

Prevent or minimise SO2
quench tower can also protect the amine from
ingress into the downstream amine system.
If SO2 does get into the amine system, it will SO2 breakthroughs. However, when an SO2
act as a heat stable salt and increasingly deacti- breakthrough occurs, if action is not taken
vate the amine and increase solution corrosivity promptly to control the quench water pH, seriat higher concentrations. Over time, degradation ous corrosion in the upper reaches of the quench
of the MDEA into secondary fragments such as tower and its internals can result because of the
DEA and MMEA will occur causing increased highly acidic environment. As shown by ProTreat
reactivity with CO2 and lowering the selectivity simulation, the level of acidity inside the column
achievable in the TGTU. Reduced selectivity is not truly indicated by measuring the pH of the
means more CO2 gets recycled back to the front entering or leaving quench water stream.
of the SRU, both reducing the quality of the feed Elemental sulphur will also form when H2S hits
gas and possibly overloading the TGTU with SO2 laden quench water, plugging the internals.
All of this can happen without any indication
additional inert gas (CO2).
SO2 can essentially be totally removed from from outlet pH measurements. In the end, the
the quench water by maintaining it pH-neutral capacity reductions and corrosion implications
or slightly alkaline. Adding caustic soda to the mandate close attention to this important piece
quench water is a common way to do this. But it of equipment.
should be recognised that any excess caustic will
serve to remove H2S and CO2 with the quench
purge. Keeping the pH alkaline also ensures that ProTreat is a mark of Optimized Gas Treating, Inc.
SO2 is converted by H2S to thiosulphate rather
than elemental sulphur. Rather than adding yet
another species (sodium) to the system, it might
Notes
be better just to add enough ammonia to keep
1 This is not a typical feed gas temperature. Many plants have
the quench water neutral.

Conclusion
The quench tower in an SRU-TGTU system does
more than cool the gas before it enters the TGTU
amine system. When operated properly, the

www.digitalrefining.com/article/1001271

a waste heat recovery exchanger upstream of the quench tower


generating LP steam (3 to 4 barg).
2 The discussion is in terms of molar flow rates rather than molar
concentrations because the large changes in water concentration
significantly affect the concentrations of other species and can
mask important variations.

Gas 2016 5

Ralph H Weiland is President of Optimized Gas Treating, Inc (OGT).


He holds BASc, MASc and PhD degrees in chemical engineering
from the University of Toronto.
Email: Ralph.Weiland@ogtrt.com
Nathan (Nate) A Hatcher is Vice President, technology
development for OGT. He holds a BS in chemical engineering from
the University of Kansas.
Email: Nathan.Hatcher@ogtrt.com
Clayton Jones joined Optimized Gas Treating, Inc as a Software
Development Engineer in 2012. He holds a BS in chemical
engineering from McNeese State University and a MS in chemical
engineering from the University of New Mexico.

6 Gas 2016