Quench Towers Published Paper
Quench Towers Published Paper
Quench Towers Published Paper
quench towers
A quench tower cools gas entering a tail gas amine unit but also protects the
amine against SO2 breakthrough
Ralph Weiland, Clayton Jones and Nathan Hatcher Optimized Gas Treating, Inc
www.digitalrefining.com/article/1001271
Case study
For this study, the TGTU quench column and
quench water circuit shown in Figure 1 have
been isolated from the overall SRU-TGTU flowsheet The column contains 20 ft (6.1 m) of IMTP
50 random packing. The gas enters at 15 psia
(1.03 bara) and 555F (290C)1 with the compo-
Gas 2016 1
To amine
section
Flow,
Flow,
lbmol/h kmol/h
Water
307.1
139.3
Carbon dioxide
82.6
37.5
Hydrogen sulphide 8.3
3.76
Sulphur dioxide
Trace
Trace
Ammonia
0.051
0.023
Hydrogen
41.3
18.7
Carbon monoxide
0.3
0.136
Nitrogen
583.3
264.6
Total
1023 464
Tear
Quench
column
Quench
feed
Quench
cooler
Table 1
2
9
To quench
purge
Bleed
300 bbl/h
450 bbl/h
683 bbl/h
10
15
20
100
200
300
400
500
600
Temperature, F
0
300 bbl/h
450 bbl/h
683 bbl/h
10
15
20
100
200
300
2 Gas 2016
400
500
Gas cooling
Figure 2a shows temperature profiles across the
column while Figure 2b shows the changing flow
rate of water in the gas. The parameter in these
plots is the circulation rate of the quench water.
www.digitalrefining.com/article/1001271
! + ! !! + !
!! + !! !! !!
2!! + !! (!! )! !!
10
15
20
0.02
0.04
0.06
0.08
0.10
0.12
0.54
1.00
1.50
2.00
10
15
www.digitalrefining.com/article/1001271
Gas 2016 3
0.54
1.00
1.50
2.00
4 Gas 2016
www.digitalrefining.com/article/1001271
2
4
6
8
10
12
14
16
18
20
3.5
0.1
0.5
1.0
2.0
3.0
4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5
When an SO2 breakthrough
pH
from the SRU occurs, it is
important to:
Figure 5 pH Profile in the quench column at 300 bbl/h (solid lines) and
Detect the breakthrough,
Protect the quench tower and 683 bbl/d (dashed lines) quench water rate, SO2 to NH3 ratio as parameter,
its internals from rapid acidic and 100 ppmv SO2 in the gas. Parameter is SO2 to NH3 ratio in feed gas to
quench tower
corrosion
Prevent or minimise SO2
quench tower can also protect the amine from
ingress into the downstream amine system.
If SO2 does get into the amine system, it will SO2 breakthroughs. However, when an SO2
act as a heat stable salt and increasingly deacti- breakthrough occurs, if action is not taken
vate the amine and increase solution corrosivity promptly to control the quench water pH, seriat higher concentrations. Over time, degradation ous corrosion in the upper reaches of the quench
of the MDEA into secondary fragments such as tower and its internals can result because of the
DEA and MMEA will occur causing increased highly acidic environment. As shown by ProTreat
reactivity with CO2 and lowering the selectivity simulation, the level of acidity inside the column
achievable in the TGTU. Reduced selectivity is not truly indicated by measuring the pH of the
means more CO2 gets recycled back to the front entering or leaving quench water stream.
of the SRU, both reducing the quality of the feed Elemental sulphur will also form when H2S hits
gas and possibly overloading the TGTU with SO2 laden quench water, plugging the internals.
All of this can happen without any indication
additional inert gas (CO2).
SO2 can essentially be totally removed from from outlet pH measurements. In the end, the
the quench water by maintaining it pH-neutral capacity reductions and corrosion implications
or slightly alkaline. Adding caustic soda to the mandate close attention to this important piece
quench water is a common way to do this. But it of equipment.
should be recognised that any excess caustic will
serve to remove H2S and CO2 with the quench
purge. Keeping the pH alkaline also ensures that ProTreat is a mark of Optimized Gas Treating, Inc.
SO2 is converted by H2S to thiosulphate rather
than elemental sulphur. Rather than adding yet
another species (sodium) to the system, it might
Notes
be better just to add enough ammonia to keep
1 This is not a typical feed gas temperature. Many plants have
the quench water neutral.
Conclusion
The quench tower in an SRU-TGTU system does
more than cool the gas before it enters the TGTU
amine system. When operated properly, the
www.digitalrefining.com/article/1001271
Gas 2016 5
6 Gas 2016
LINKS
More articles from: Optimized Gas Treating
More articles from the following categories:
Gas Processing and Treatment
Process Modelling and Simulation
www.digitalrefining.com/article/1001271