Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SL 012r Pe LV G

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Data Sheet

RF_35/05.10/6.0

Dieses Dokument ist urheberrechtlich geschtzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG

SLink
Cable

1/2R PE

SL 012R PE

This product used for mobile network and telecommunication equipment

Material and dimensions


Inner conductor
Dielectric
Outer conductor
Jacket
Ink markingmetric length

Copper Clad Aluminum wire


4.8 mm
Foam PE
12.2 mm
Corrugated copper(Annularly)
13.8 mm
PE, Black, UV resistant, Halogen free
15.9 mm
RosenbergerSLinkTM_SL 012R_PE_50_ _ _ _ _(DD+MM
+SS+YY+NNNNN)_ _ _ _ _XXXXm

Documents
UV resistance

GB/T 2423.24-1995 ; EN 50289-4-17, Method A

Electrical Specification
Impedance
Relative Velocity of Propagation
Capacitance
Inductance
Maximum Operating Frequency
Cut-off Frequency
Peak Power Rating
Insulation Resistance
DC Breakdown Voltage
Jacket Spark Test Voltage
Inner Conductor DC-resistance
Outer Conductor DC-resistance

50 1
88%
76 pF/m
0.190 H/m
8.8 GHz
10.0 GHz
40 kW
10 G x km
6000V
8000 Vrms
1.55 /km
2.7 /km

Environmental Specification
Installation Temperature
Operating Temperature
Storage Temperature
RoHS

-25C to +60C
-40C to +85C
-70C to +85C
compliant

Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany


Tel.: +49 8684 18-0
Fax: +49 8684 18-499
www.rosenberger.de
email: info@rosenberger.de

Rosenberger Asia Pacific Electronic Co., Ltd., China


Tel.: +86 10 80481995
Fax: +86 10 80497052
www.rosenbergerap.com
email:info@rosenbergerap.com

Page
1/2

Technical Data Sheet


SLink
Cable

1/2R PE

SL 012R PE

RF_35/05.10/6.0

Dieses Dokument ist urheberrechtlich geschtzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG

Mechanical Specification
Cable weight
Tensile strength
Min. bending radius (single)
Min. bending radius (repeated)
Number of bends, minimum (typical)
Bending moment
Flat plate crush strength
Recommended hanger spacing

200 kg/km
1150 N
70 mm
125 mm
15 (50)
5 Nm
20 N/mm
0.8 m

Standard Conditions
Attenuation, Ambient Temperature
Average Power, Ambient Temperature
Average Power, Inner Conductor
Temperature

20C
40C
100C

Return Loss
-26dB 800 to 1000MHz
-24dB 1700 to 1900MHz
-24dB 1900 to 2200MHz
-24dB 2200 to 2500MHz
-24dB 2500 to 3000MHz

Return loss(Band A)
Return loss(Band B)
Return loss(Band C)
Return loss(Band D)
Return loss(Band E)

Attenuation
Frequency (MHz)
100
200
300
400
450
800
900
1000
1800
2000
2200
2500
2700
3000

Attenuation (dB/100m)
2.15
3.08
3.81
4.46
4.70
6.35
6.75
7.20
9.90
10.50
11.10
11.95
12.47
13.20

Average Power (KW)


3.94
2.75
1.99
1.80
1.80
1.33
1.25
1.18
0.86
0.81
0.77
0.73
0.69
0.65

Maximum attenuation value shall be 105% of the nominal attenuation value


Other frequencies on request

While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft

Date

Check

Approved

Date

Rev.

Engineering change number

Name

Date

Feifei

13/12/11

James

heanyang

28/08/15

15-1121

huanghuan

20/08/15

Rosenberger Hochfrequenztechnik GmbH & Co. KG, Germany


Tel.: +49 8684 18-0
Fax: +49 8684 18-499
www.rosenberger.de
email: info@rosenberger.de

Rosenberger Asia Pacific Electronic Co., Ltd., China


Tel.: +86 10 80481995
Fax: +86 10 80497052
www.rosenbergerap.com
email:info@rosenbergerap.com

Page
2/2

You might also like