Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

IEC 60079-29-1 Gas Detectors - Performance Requirements of Detectors For Flammable Gases-2007

Download as pdf or txt
Download as pdf or txt
You are on page 1of 104
At a glance
Powered by AI
The document discusses performance requirements and testing standards for gas detectors used in explosive atmospheres.

The document discusses standards for gas detection and preparation of gas mixtures for calibration using dynamic volumetric methods.

Standards such as ISO 4003, ISO 4022, ISO 6142, ISO 6145 and others are mentioned in relation to gas detection and analysis.

CS 5126

IEC 60079-29-1
Edition 1.0

2007-08

INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

FOR OFFICE USE ONLY

Explosive atmospheres
Part 29-1: Gas detectors Performance requirements of detectors for flammable
gases

IEC 60079-29-1:2007

Atmosphres explosives
Partie 29-1: Dtecteurs de gaz Exigences daptitude la fonction des
dtecteurs de gaz inflammables

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

THIS PUBLICATION IS COPYRIGHT PROTECTED

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction rservs. Sauf indication contraire, aucune partie de cette publication ne peut tre reproduite
ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie
et les microfilms, sans l'accord crit de la CEI ou du Comit national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette
publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence.
IEC Central Office
3, rue de Varemb
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch

About the IEC


The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications


The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00

A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la premire organisation mondiale qui labore et publie des
normes internationales pour tout ce qui a trait l'lectricit, l'lectronique et aux technologies apparentes.

A propos des publications CEI


Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez
ldition la plus rcente, un corrigendum ou amendement peut avoir t publi.
Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet deffectuer des recherches en utilisant diffrents critres (numro de rfrence,
texte, comit dtudes,). Il donne aussi des informations sur les projets et les publications retires ou remplaces.
Just Published CEI: www.iec.ch/online_news/justpub
Restez inform sur les nouvelles publications de la CEI. Just Published dtaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 20 000 termes et
dfinitions en anglais et en franais, ainsi que les termes quivalents dans les langues additionnelles. Egalement appel
Vocabulaire Electrotechnique International en ligne.
Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tl.: +41 22 919 02 11
Fax: +41 22 919 03 00

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright 2007 IEC, Geneva, Switzerland

IEC 60079-29-1
Edition 1.0

2007-08

INTERNATIONAL
STANDARD
NORME
INTERNATIONALE

Explosive atmospheres
Part 29-1: Gas detectors Performance requirements of detectors for flammable
gases
Atmosphres explosives
Partie 29-1: Dtecteurs de gaz Exigences daptitude la fonction des
dtecteurs de gaz inflammables

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION

PRICE CODE
CODE PRIX

ISBN 2-8318-9249-X

ICS 29.260.20

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE

60079-29-1 IEC:2007

CONTENTS
FOREWORD...........................................................................................................................5
INTRODUCTION.....................................................................................................................8
1

Scope ...............................................................................................................................9

Normative references ..................................................................................................... 10

Definitions ...................................................................................................................... 10

3.1 Gas properties....................................................................................................... 10


3.2 Types of instruments ............................................................................................. 12
3.3 Sensors ................................................................................................................. 13
3.4 Supply of gas to instrument ................................................................................... 13
3.5 Signals and alarms ................................................................................................ 13
3.6 Times .................................................................................................................... 14
3.7 Miscellaneous ....................................................................................................... 14
General requirements ..................................................................................................... 15
4.1
4.2

Introduction ........................................................................................................... 15
Construction .......................................................................................................... 16
4.2.1 General ..................................................................................................... 16
4.2.2 Indicating devices ...................................................................................... 16
4.2.3 Alarm or output functions ........................................................................... 17
4.2.4 Fault signals .............................................................................................. 18
4.2.5 Adjustments .............................................................................................. 18
4.2.6 Battery-powered apparatus........................................................................ 18
4.2.7 Stand-alone gas detection apparatus for use with separate control
units .......................................................................................................... 18
4.2.8 Separate control units for use with stand-alone gas detection
apparatus .................................................................................................. 19
4.2.9 Software-controlled apparatus ................................................................... 19
4.3 Labelling and marking ........................................................................................... 21
4.4 Instruction manual ................................................................................................. 21
Test methods ................................................................................................................. 22
5.1
5.2

5.3

Introduction ........................................................................................................... 22
General requirements for tests .............................................................................. 22
5.2.1 Samples and sequence of tests ................................................................. 22
5.2.2 Preparation of apparatus before testing ..................................................... 23
5.2.3 Mask for calibration and tests .................................................................... 24
Normal conditions for test...................................................................................... 24
5.3.1 General ..................................................................................................... 24
5.3.2 Test gas(es) .............................................................................................. 24
5.3.3 Standard test gas ...................................................................................... 25
5.3.4 Flow rate for test gases ............................................................................. 25
5.3.5 Voltage ...................................................................................................... 25
5.3.6 Temperature .............................................................................................. 25
5.3.7 Pressure.................................................................................................... 25
5.3.8 Humidity .................................................................................................... 25
5.3.9 Stabilization time ....................................................................................... 26
5.3.10 Orientation ................................................................................................ 26
5.3.11 Communications options............................................................................ 26

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

5.4

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5.3.12 Gas detection apparatus as part of systems .............................................. 26


Test methods ........................................................................................................ 26
5.4.1 General ..................................................................................................... 26
5.4.2 Unpowered storage ................................................................................... 26
5.4.3 Calibration and adjustment ........................................................................ 26
5.4.4 Stability (continuous duty apparatus only).................................................. 27
5.4.5 Stability (spot-reading apparatus only)....................................................... 28
5.4.6 Alarm set point(s) ...................................................................................... 28
5.4.7 Temperature .............................................................................................. 29
5.4.8 Pressure.................................................................................................... 29
5.4.9 Humidity .................................................................................................... 29
5.4.10 Air velocity ................................................................................................ 29
5.4.11 Flow rate for aspirated apparatus .............................................................. 30
5.4.12 Orientation ................................................................................................ 30
5.4.13 Vibration .................................................................................................... 30
5.4.14 Drop test for portable and transportable apparatus .................................... 31
5.4.15 Warm-up time ............................................................................................ 31
5.4.16 Time of response (not applicable to spot-reading apparatus) ..................... 32
5.4.17 Minimum time to operate (spot-reading apparatus) .................................... 32
5.4.18 High gas concentration operation above the measuring range ................... 32
5.4.19 Battery capacity......................................................................................... 33
5.4.20 Power supply variations ............................................................................. 33
5.4.21 Power supply interruptions, voltage transients and step changes of
voltage ...................................................................................................... 34
5.4.22 Addition of sampling probe ........................................................................ 34
5.4.23 Dust (for apparatus where the air is sampled by natural diffusion
only) .......................................................................................................... 34
5.4.24 Poisons and other gases ........................................................................... 34
5.4.25 Electromagnetic immunity .......................................................................... 35
5.4.26 Field calibration kit .................................................................................... 36
5.4.27 Software verification .................................................................................. 36

Annex A (normative) Performance requirements .................................................................. 37


Annex B (informative) Determination of time of response ..................................................... 42
Bibliography.......................................................................................................................... 49
Figure 1 Warm-up time in clean air (typical) ....................................................................... 15
Figure 2 Warm-up time in standard test gas (typical) ......................................................... 15
Figure B.1 Schematic example of equipment for use with aspirated apparatus .................. 44
Figure B.2 Schematic example of equipment during application of clean air or test gas .... 45
Figure B.3 Schematic example of equipment showing change-over from clean air to
test gas to begin the time of response measurement (arrows indicate movement of
applicators) ........................................................................................................................... 45

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

Figure B.4 Schematic example of applicator and sensor inlet during application of
test gas or clean air .............................................................................................................. 46
Figure B.5 Example of automated test chamber ................................................................. 47
Figure B.6 Apparatus for step change and flooding tests.................................................... 48

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Table A.1 Performance requirements ................................................................................. 37

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

INTERNATIONAL ELECTROTECHNICAL COMMISSION


____________
EXPLOSIVE ATMOSPHERES
Part 29-1: Gas detectors
Performance requirements of detectors for flammable gases
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as IEC
Publication(s)). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.

6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 60079-29-1 has been prepared by IEC technical committee 31:
Equipment for explosive atmospheres.
This first edition of IEC 60079-29-1 cancels and replaces the first edition of IEC 61779-1 to
IEC 61779-5:1998 series and constitutes a technical revision.
The main changes with respect to the previous edition are listed below:

Subclause 4.2.3 (Alarm or output functions) was modified to ensure alarm devices can not
be adjustable outside their measuring range and to include requirements for de-activation
of alarm devices.

Subclause 4.2.7 (Stand-alone gas detection apparatus for use with separate control units)
was added to allow separate evaluation of detection apparatus providing an industry
recognized output signal.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.

60079-29-1 IEC:2007

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Subclause 4.2.8 (Separate control units for use with stand-alone gas detection apparatus)
was added to allow separate evaluation of control unit apparatus using an industry
recognized input signal.

Subclause 4.2.9 (Software-controlled apparatus) was added to the document for improved
evaluation of software. The added text is based upon the guiding principles and
requirements of EN 50271.

Subclause 4.5 (Diffusion sensors) was removed from the document based upon the
redundant protection allowance for equipment used in Zone 0 areas, such as Ex d ia rated
equipment.

Subclause 5.2.1.1 was modified to require the center wavelength of the optical filters of
two apparatus at the minimum and maximum limit of this standard.

Subclause 5.2.1.2 was modified to allow the order of testing within each block to be
conducted at the discretion of the test laboratory.

Subclause 5.3.11 (Communications options) was added to ensure maximum transaction


rates are applied during testing.

Subclause 5.3.12 (Gas detection apparatus as part of systems) was added to ensure
maximum transaction rates are applied during testing.

Subclause 5.4.6 (Alarm set point(s)) was modified to include text related to alarms that are
activated at decreasing concentrations.

Subclause 5.4.10 (Air velocity) was modified to include testing at 3 m/s and 6 m/s.

Subclause 5.4.16 (Time of response) was modified to exclude recovery time test
requirements for Group II apparatus with a volume fraction up to 100 % LFL indication.

Subclause 5.4.18 (High gas concentration operation above the measuring range) was
modified to define the sequence of tests.

Annex A (Performance requirements) has undergone major modifications by eliminating


the gas/vapour table and replacing the annex with the performance requirements of Parts
2 to 5 of the former edition. Additionally, performance requirements of Parts 2 to 5 were
adjusted for consistency as appropriate. The intent of this change is to condense Parts 1
to 5 within a single standard.

This part of IEC 60079-29 is to be used in conjunction with the following standards:

IEC 60079-0, Electrical apparatus for explosive gas atmospheres Part 0: General
requirements

IEC 60079-29-2, Explosive atmospheres Part 29-2: Gas detectors Selection,


installation, use and maintenance of detectors for flammable gases and oxygen.

The text of this standard is based on the following documents:


FDIS

Report on voting

31/695/FDIS

31/711/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

A list of all parts of the IEC 60079 series, under the general title: Explosive atmospheres, can
be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be

reconfirmed,
withdrawn,
replaced by a revised edition, or
amended.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

60079-29-1 IEC:2007

INTRODUCTION
Guidance for the selection, installation, use and maintenance of gas detecting apparatus are
set out in IEC 60079-29-2: Explosive atmospheres Part 29-2: Gas detectors Selection,
installation, use and maintenance of detectors for flammable gases and oxygen.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

EXPLOSIVE ATMOSPHERES
Part 29-1: Gas detectors
Performance requirements of detectors for flammable gases

Scope

This part of IEC 60079-29 specifies general requirements for construction, testing and
performance, and describes the test methods that apply to portable, transportable and fixed
apparatus for the detection and measurement of flammable gas or vapour concentrations with
air. The apparatus, or parts thereof, are intended for use in potentially explosive atmospheres
(see 3.1.8) and in mines susceptible to firedamp.
This standard is also applicable when an apparatus manufacturer makes any claims regarding
any special features of construction or superior performance that exceed these minimum
requirements. In these cases, all such claims should be verified and the test procedures
should be extended or supplemented, where necessary, to verify the performance claimed by
the manufacturer. When verifying the superior performance of one criterion, other
performance criteria are not required to meet the standards minimum requirements, however,
these reduced claimed performance criteria (as confirmed in the manufactures Installation
Manual) should also be verified. (e.g. temperature range of 0 C to 60 C; 0 C to 40 C at
10 % accuracy and 40 C to 60 C at 15 % (manufacturers claimed accuracy). The
additional tests should be agreed between the manufacturer and test laboratory and identified
and described in the test report.
This standard is applicable to flammable gas detection apparatus intended to provide an
indication, alarm or other output function; the purpose of which is to give a warning of a
potential explosion hazard and in some cases, to initiate automatic or manual protective
action(s).
This standard is applicable to apparatus, including the integral sampling systems of aspirated
apparatus, intended to be used for commercial, industrial and non-residential safety
applications.
This standard does not apply to external sampling systems, or to apparatus of laboratory or
scientific type, or to apparatus used only for process control purposes. It also does not apply
to open path (line of sight) area monitors. For apparatus used for sensing the presence of
multiple gases, this standard applies only to the detection of flammable gas or vapour.
This standard supplements and modifies the general requirements of IEC 60079-0. Where a
requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of
IEC 60079-29-1 will take precedence.
NOTE 1 IEC 60079-29-1 is intended to provide for the supply of apparatus giving a level of safety and
performance suitable for general purpose applications. However, for specific applications, a prospective purchaser
(or an appropriate authority) may additionally require the apparatus to be submitted to particular tests or approval.
For example, group I apparatus (i.e. apparatus to be used in mines susceptible to firedamp) may not be permitted
to be used without the additional, prior approval of the relevant authority in mines under its jurisdiction. Such
particular tests/approval are to be regarded as additional to and separate from the provisions of the standards
referred to above and do not preclude certification to or compliance with these standards.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

10

60079-29-1 IEC:2007

NOTE 2 All apparatus calibrated on specific gases or vapours can not be expected to correctly indicate on other
gases or vapours.
NOTE 3 For the purposes of this standard, the terms "lower flammable limit (LFL)" and "lower explosive limit
(LEL)" are deemed to be synonymous, and likewise the terms "upper flammable limit (UFL)" and "upper explosive
limit (UEL)" are deemed to be synonymous. For ease of reference, the two abbreviations LFL and UFL may be
used hereinafter to denote these two sets of terms. It should be recognized that particular authorities having
jurisdiction may have overriding requirements that dictate the use of one of these sets of terms and not the other.
NOTE 4 For the purposes of this standard, the term indicating up to a volume fraction of X % includes apparatus
with an upper limit of the measuring range equal to or less than X %.

Normative references

The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60079-0: Electrical apparatus for explosive gas atmospheres Part 0: General
requirements
IEC 60079-20: Electrical apparatus for explosive gas atmospheres Part 20: Data for
flammable gases and vapours, relating to the use of electrical apparatus
IEC 60079-29-2, Explosive atmospheres Part 29-2: Gas detectors Selection, installation,
use and maintenance of detectors for flammable gases and oxygen
IEC 61000-4-1: Electromagnetic compatibility (EMC) Part 4-1: Testing and measurement
techniques Overview of IEC 61000-4 series. Basic EMC publication
IEC 61000-4-3: Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement
techniques Radiated, radio-frequency, electromagnetic field immunity test. Basic EMC
publication
IEC 61000-4-4: Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement
techniques Electrical fast transient/burst immunity test Basic EMC publication

Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 60079-0 and the
following apply.
NOTE Additional definitions applicable to explosive atmospheres can be found in Chapter 426 of the International
Electrotechnical Vocabulary (IEV) IEC 60050 (426).

3.1

Gas properties

3.1.1
ambient air
normal atmosphere surrounding the apparatus
3.1.2
clean air
air that is free of flammable gases and interfering or contaminating substances

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

11

3.1.3
explosive gas atmosphere
mixture with air, under normal atmospheric conditions, of flammable substances in the form of
gas or vapour, in which, after ignition, self-sustaining flame propagation
NOTE 1 This definition specifically excludes dusts and fibres in suspension in air. Mists are not covered by this
standard.
NOTE 2 Although a mixture that has a concentration above the upper flammable limit (see 3.1.9) is not an
explosive atmosphere, in certain cases for area classification purposes, it is advisable to consider it as an
explosive gas atmosphere.
NOTE 3 Normal atmospheric conditions include variations above and below the reference levels of 101,3 kPa and
20 C provided the variations have a negligible effect on the explosive properties of the flammable materials.

3.1.4
firedamp
flammable gas, consisting mainly of methane, found naturally in mines
3.1.5
flammable gas
gas or vapour which, when mixed with air in a certain proportion, will form an explosive
atmosphere
NOTE

For the purposes of this standard, the term "flammable gas" includes flammable vapours.

3.1.6
lower flammable limit
LFL
volume fraction of flammable gas or vapour in air below, which an explosive gas atmosphere
does not form, expressed as a percentage (see IEC 60079-20)
NOTE

This is also known as lower explosive limit (LEL).

3.1.7
poisons (for sensors)
substances, which lead to temporary or permanent loss of sensitivity of the sensors
3.1.8
potentially explosive atmosphere
atmosphere that could become explosive (the danger is a potential one)
NOTE This would include an atmosphere with gas concentration currently above UFL, where dilution with air
would render it explosive.

3.1.9
upper flammable limit
UFL
volume fraction of flammable gas or vapour in air above, which an explosive gas atmosphere
does not form, expressed as a percentage (see IEC 60079-20)
NOTE

This is also known as upper explosive limit (UEL).

3.1.10
volume fraction (v/v)
quotient of the volume of a specified component and the sum of the volumes of all
components of a gas mixture before mixing, all volumes referring to the pressure and the
temperature of the gas mixture

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

12

60079-29-1 IEC:2007

NOTE The volume fraction and volume concentration take the same value if, at the same state conditions, the
sum of the component volumes before mixing and the volume of the mixture are equal. However, because the
mixing of two or more gases at the same state conditions is usually accompanied by a slight contraction or, less
frequently, a slight expansion, this is not generally the case.

3.1.11
zero gas
gas recommended by the manufacturer, which is free of flammable gases, and interfering and
contaminating substances, the purpose of which is calibration/adjustment of the apparatus
zero
3.2

Types of instruments

3.2.1
alarm-only apparatus
apparatus having an alarm but not having a meter or other indicating device
3.2.2
aspirated apparatus
apparatus that samples the gas by drawing it to the gas sensor for example, by means of a
hand-operated or electric pump
3.2.3
continuous duty apparatus
apparatus that is powered for long periods of time, but may have either continuous or
intermittent sensing
3.2.4
diffusion apparatus
apparatus in which the transfer of gas from the atmosphere to the gas sensor takes place by
random molecular movement, i.e. under conditions in which there is no aspirated flow

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

3.2.5
fixed apparatus
apparatus that is intended to have all parts permanently installed
3.2.6
group I apparatus
apparatus for mines susceptible to firedamp
3.2.7
group II apparatus
apparatus for places with a potentially explosive atmosphere, other than mines susceptible to
firedamp
3.2.8
portable apparatus
spot-reading or continuous duty apparatus that has been designed to be readily carried from
place to place and to be used while it is being carried. A portable apparatus is battery
powered and includes, but is not limited to
a) a hand-held apparatus, typically less than 1 kg, which requires use of only one hand to
operate,
b) personal monitors, similar in size and mass to the hand-held apparatus, that are
continuously operating (but not necessarily continuously sensing) while they are attached
to the user, and

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

13

c) larger apparatus that can be operated by the user while it is carried either by hand, by a
shoulder strap or carrying harness and which may or may not have a hand directed probe.
3.2.9
spot-reading apparatus
apparatus intended to be used for short, intermittent or irregular periods of time as required
(typically 5 min or less)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

3.2.10
transportable apparatus
apparatus not intended to be portable but which can be readily moved from one place to
another
3.2.11
stand-alone gas detection apparatus
fixed gas detection apparatus that provide a conditioned electronic signal or output indication
to a generally accepted industry standard (such as 4-20 mA or 3-15 psi), intended to be
utilized with stand-alone control units or signal processing data acquisition, central monitoring
and similar systems, which typically process information from various locations and sources
including, but not limited to gas detection apparatus
3.2.12
stand-alone control unit
fixed gas detection control units intended to provide meter indication, alarm functions, output
contacts and/or alarm signal outputs when utilized with stand-alone gas detection apparatus
3.3

Sensors

3.3.1
remote sensor
sensor that is not integral to the main body of the apparatus
3.3.2
sensor
assembly in which the sensing element is housed and that may also contain associated circuit
components
3.4

Supply of gas to instrument

3.4.1
sample line
a means by which the gas being sampled is conveyed to the sensor including accessories,
e.g. filter, water trap
3.4.2
sampling probe
separate sample line, which is attached to the apparatus as required, that may or may not be
supplied with the apparatus. It is usually short (e.g. in the order of 1 m) and rigid (although it
may be telescopic), but it may be connected by a flexible tube to the apparatus
3.5

Signals and alarms

3.5.1
alarm set point
fixed or adjustable setting of the apparatus that is intended to preset the level of
concentration at which the apparatus will automatically initiate an indication, alarm or other
output function

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

14

60079-29-1 IEC:2007

3.5.2
fault signal
audible, visible or other type of output, different from the alarm signal, permitting, directly or
indirectly, a warning or indication that the apparatus is not working satisfactorily
3.5.3
latching alarm
alarm that, once activated, requires deliberate action to be deactivated
3.5.4
special state
all states of the apparatus other than those in which monitoring of gas concentration takes
place, for example warm-up, calibration mode or fault condition
3.6

Times

3.6.1
drift
variation in the apparatus indication with time at any fixed gas volume fraction (including
clean air) under constant ambient conditions
3.6.2
final indication
indication given by the apparatus after stabilisation
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

3.6.3
minimum time of operation (spot-reading apparatus)
time interval between the initiation of a measurement procedure and the time when the
apparatus indication reaches a stated percentage of the final indication
3.6.4
stabilisation
state when three successive readings of an apparatus, taken at 2 min intervals, indicates no
changes greater than 1 % of the measuring range

3.6.5
time of response t(x) (not applicable to spot-reading apparatus)
time interval, with the apparatus in a warmed-up condition, between the time when an
instantaneous change between clean air and the standard test gas, or vice versa, is produced
at the apparatus inlet, and the time when the response reaches a stated percentage (x) of the
stabilised signal on the standard test gas
3.6.6
warm-up time (not applicable to spot-reading apparatus)
time interval, with the apparatus in a stated atmosphere, between the time when the
apparatus is switched on and the time when the indication reaches and remains within the
stated tolerances (see Figures 1 and 2)
3.7

Miscellaneous

3.7.1
nominal supply voltage
voltage that is given by manufacturers as the recommended operating voltage of their gas
detection apparatus
3.7.2
special tool
tool required to gain access to, or to adjust, controls. The design of the tool is intended to
discourage unauthorised interference with the apparatus
Copyright International Electrotechnical Commission
Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

15

3.7.3
type of protection
measures applied in the construction of electrical equipment to prevent ignition of the
surrounding explosive atmosphere by such apparatus (see 4.1.2)

Indication

Power off in
clean air

Power on in
clean air

Specified

} tolerance band

Apparatus
0
zero

on zero indication

Time
0

Warm-up time
(see 3.6.6)

IEC 1293/07

Figure 1 Warm-up time in clean air (typical)

Indication
Power off
in standard
test gas

Power on
in standard
test gas
Specified

Volume ratio
of standard
test gas

Time

0
0

Warm-up time
(see 3.6.6)
IEC 1294/07

Figure 2 Warm-up time in standard test gas (typical)

4
4.1

General requirements
Introduction

4.1.1 The apparatus shall comply with the requirements of this standard and Annex A
criteria.

Where an apparatus manufacturer makes any claims regarding any special features of
construction or superior performance that exceed these minimum requirements, all such
claims shall be verified and the test procedures shall be extended or supplemented, where
necessary, to verify the claimed performance.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Zero in
clean air

of
} tolerances
the indication

16

60079-29-1 IEC:2007

4.1.2 Electrical assemblies and components shall comply with the construction and test
requirements of 4.2 and Clause 5, where applicable. In addition, parts of the flammable gas
detection apparatus intended for use in hazardous areas shall employ materials, and comply
with the construction and explosion protection as specified in the other relevant parts of
IEC 60079 series.

The operation and storage temperature limits of this standard could exceed the required
temperature limits of these other parts of IEC 60079 for certain types of equipment.
Therefore, the certification of the protection technique(s) used for the apparatus shall cover
this extended temperature range. Conversely, where the certification is required outside the
normal temperature limits appropriate to the protection technique(s) used, the test
temperature exceeding the required ranges within this standard shall be changed
appropriately.
4.1.3 For group I apparatus any electrical circuits to be installed in the same area as the
sensor, including those within the sensor, shall be intrinsically safe ("ia"); the sensing
elements shall be intrinsically safe, or their enclosures shall comply with the safety
requirements specified in 4.1.2.
4.2

Construction

4.2.1

General

Gas detection apparatus or parts thereof (e.g. remote sensors) specifically intended for use in
the presence of corrosive vapours or gases, or which may produce corrosive by-products as a
result of the detection process (e.g. catalytic oxidation or other chemical process) shall be
constructed of materials known to be resistant to corrosion by such substances.
All apparatus shall be constructed to facilitate regular accuracy checks.
All materials and components used in the construction of the apparatus shall be used within
the manufacturer's ratings or limitations, unless otherwise specified by appropriate safety
standards.
NOTE Apparatus using absorption principles where the gas is sampled by diffusion would typically be expected to
have an optical chamber length of up to 30 cm. However, for special applications a longer fixed optical chamber
length may be employed for point detection purposes.

4.2.2

Indicating devices

4.2.2.1

General

An indication shall be provided to show that the apparatus is energized.


NOTE

For fixed apparatus the indication may be shown at the control unit.

4.2.2.2

Resolution

For alarm-only apparatus or apparatus where the resolution of the read-out device is
inadequate to demonstrate compliance with this standard, the manufacturer shall identify
suitable points for connecting indicating or recording devices for the purpose of testing the
compliance of the apparatus with this standard. The indication on the readout device shall not
contradict the results obtained by additional indicating or recording devices.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

60079-29-1 IEC:2007
4.2.2.3

17

Measurement range

Any under-range or over-range measurements shall be clearly indicated as such.


4.2.2.4

Selectable range

If the apparatus has more than one measuring range, the range selected shall be clearly
identified.
4.2.2.5

Indicating light

If only one indicating light is provided for signalling alarms, faults and other indications, it
shall be coloured red. If separate indicating lights are used or if a multi-coloured indicating
light is provided, the colours shall be used in the following order of priority ((a) being highest
priority):
a) alarms indicating the presence of a gas concentration beyond an alarm set point shall be
coloured RED;
b) equipment fault indicators shall be coloured YELLOW;
c) power supply indicators shall be coloured GREEN.
4.2.2.6

Indicator light marking

In addition to the colour requirements, the indicator lights shall be adequately labelled to show
their functions.
4.2.3

Alarm or output functions

4.2.3.1

General

Alarm devices shall not be adjustable to operate outside the measuring range.
4.2.3.2

Continuous duty apparatus

If alarm devices, output contacts or alarm signal outputs are provided as part of fixed or
continuous duty portable apparatus and are intended to operate when a potentially hazardous
gas concentration is detected, they shall be of a latching type requiring a deliberate manual
action to reset. If two or more alarm set points are provided, the lower may be non-latching
based on user preference. Alarms shall remain in operation while the alarm condition is still
present. An additional audible alarm may be silenced.
NOTE

The latching device may reside in software.

If it is possible to de-activate alarm devices, output contacts or alarm signal outputs, e.g. for
calibration purposes, this deactivation shall be indicated by a signal. For fixed apparatus, this
shall include a contact or other transmittable output signal. Alternatively, the output signal or
contacts are not required if the alarms are automatically re-enabled within 15 min.
4.2.3.3

Group I portable apparatus indicating up to 5 % v/v

Alarm devices shall not be adjustable above 3 % v/v. An additional over-range alarm, which
indicates when full scale has been exceeded, may be provided.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

18
4.2.3.4

60079-29-1 IEC:2007

Group II portable apparatus indicating up to 100 % LFL

Alarm devices shall not be adjustable above 60 % LFL. An additional over-range alarm, which
indicates when full scale has been exceeded, may be provided.
NOTE For other group II apparatus, it is recommended that alarm devices should be set to operate at a gas
volume fraction not higher than 60 % LFL.

4.2.4

Fault signals

Fixed and transportable apparatus shall provide a fault signal in the event of failure of power
to the apparatus.
A short-circuit or open-circuit in connections to any remote sensor shall be indicated by a fault
signal.
Automatically aspirated apparatus shall be provided:
a) in the case of fixed and transportable apparatus, with an integral flow-indicating device
that produces a fault signal in the event of flow failure,
b) in the case of portable apparatus, with a means of verifying the air flow.
4.2.5

Adjustments

All adjustment devices shall be designed so as to discourage unauthorized or inadvertent


interference with the apparatus. Examples would include procedural devices, in the case of a
keyboard instrument, or mechanical devices such as a cover requiring the use of a tool.
Fixed explosion-protected apparatus housed in explosion-protected enclosures shall be
designed so that, if any facilities for adjustment are necessary for routine recalibration and for
resetting or like functions, these facilities shall be externally accessible. The means for
making adjustments shall not degrade the explosion protection of the apparatus.
The adjustments of the zero and signal amplification shall be so designed that adjustment of
one will not affect the other.
4.2.6

Battery-powered apparatus

Apparatus powered with integral batteries shall be provided with an indication of low battery
condition, and the nature and purpose of this indication shall be explained in the manual
(see 4.4 j)).
4.2.7

Stand-alone gas detection apparatus for use with separate control units

A specification shall be supplied with the apparatus that describes the relationship the gas
concentration (detected by the apparatus) has with the corresponding output signal or
indication (transfer function). Such specification shall be detailed to the extent that the
accuracy of this transfer function can be verified. As a minimum, the manufacturer shall
provide data showing the relationship between the output signal and the gas concentrations
corresponding to 0, 10 %, 25 %, 50 %, 75 % and 100 % of full-scale output indication. Fullscale output and status signals (e.g. fault, inhibit) shall also be specified by the manufacturer.
Where necessary, equipment shall be provided by the manufacturer to interpret the output
signal or indication, which will enable the accuracy of the transfer function to be verified.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007
4.2.8

19

Separate control units for use with stand-alone gas detection apparatus

A specification shall be supplied with the apparatus that describes the relationship the input
signal has with the calculated gas concentration (transfer function). Such specification shall
be detailed to the extent that the accuracy of this transfer function can be verified. As a
minimum, the manufacturer shall provide data showing the relationship between the input
signal and the gas concentrations corresponding to 0, 10 %, 25 %, 50 %, 75 % and 100 % of
full-scale output indication. Required inputs for full-scale indication and status signals (e.g.
fault, inhibit) shall also be specified by the manufacturer.
Where necessary, equipment shall be provided by the manufacturer to provide the input
signals, which will enable the accuracy of the transfer function to be verified.
4.2.9

Software-controlled apparatus

In the design of software-controlled apparatus, the risks arising from faults in the programme
shall be taken into account.
4.2.9.1

Conversion errors

The relationship between corresponding analogue and digital values shall be unambiguous.
The output range shall be capable of coping with the full range of input values within the
instrument specification. A clear indication shall result if the conversion range has been
exceeded.
The design shall take into account the maximum possible analogue-to-digital, computational
and digital-to-analogue converter errors. The combined effect of digitisation errors shall not
be greater than the smallest deviation of indication required by this standard.
4.2.9.2

Special state indication

If a special state is entered by an apparatus this shall be indicated by a signal. For fixed
apparatus, this shall include a contact or other transmittable output signal.
4.2.9.3

Software

Software components shall comply with the following:


a) It shall be possible for the user to identify the installed software version, for example by
marking on the installed memory component, in (if accessible) or on the apparatus or by
showing it on the display during power up or on user command.
b) It shall not be possible for the user to modify the program code.
c) Parameter settings shall be checked for validity. Invalid inputs shall be rejected. An
access barrier shall be provided against parameter changing by unauthorised persons,
e.g. it may be integrated by an authorisation code in the software or may be realised by a
mechanical lock. Parameter settings shall be preserved after removal of power, and while
passing a special state. All user changeable parameters and their valid ranges shall be
listed in the manual.
d) Software shall have a structured design to facilitate testing and maintenance. If used,
program modules shall have a clearly defined interface to other modules.
e) Software documentation shall be included in the technical file of the product. It shall
include:
1) the apparatus to which the software belongs;

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

20

60079-29-1 IEC:2007

2) unambiguous identification of program version;


3) functional description;
4) software structure (e.g. flow chart, Nassi-Schneidermann diagram);
5) any software modification provided with the date of change and new identification data.
4.2.9.4

Data transmission

Digital data transmission between spatially separated components of apparatus shall be


reliable. Delays resulting from transmission errors shall not extend the response time t 90 or
time to alarm for alarm only apparatus by more than a third. If they do, the apparatus shall
pass over to a defined special state. The defined special state shall be documented in the
instruction manual.
4.2.9.5

Self-test routines

Computerised digital units shall incorporate self-test routines. On failure detection, the
apparatus shall pass over to a defined special state. The defined special state shall be
documented in the instruction manual.
The following minimum tests shall be performed by the apparatus:
a) power supply of digital units shall be monitored within time intervals of maximum ten times
response time t (90) or time to alarm for alarm only apparatus
b) all available visible and audible output functions shall be tested. The test shall be carried
out automatically after starting operation or on user request. The result may need to be
verified by the user
c) monitoring equipment with its own time base (e.g. watchdog) shall work independently and
separately from the parts of the digital unit, which perform the data processing;
d) program and parameter memory shall be monitored by procedures, which allow the
detection of a single bit error
e) volatile memory shall be monitored by procedures that test the readability and writeability
of the memory cells.
The tests except for test b) shall be done automatically and be repeated cyclically equal to or
less than 24 h and after switching on.
4.2.9.6

Functional concept

The manufacturer shall provide documentation for functional concept analysis and evaluation
using the following list:

measuring sequence (including all possible variations),

possible special states,

parameters and their tolerable adjustment range,

generation of alarms and signals,

extent and realisation of test routines,

extent and realisation of remote data transmission.

representation of measuring values and indications,

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007
4.3

21

Labelling and marking

The apparatus shall comply with the marking requirements of IEC 60079-0
NOTE Electrical equipment, which does not fully comply with the relevant parts of IEC 60079-0 but where
equivalent safety is claimed, should be marked with the symbol s.

In addition, the apparatus shall also be marked:


a) IEC 60079-29-1 (to represent conformance with this performance standard);
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

b) year of construction (may be encoded within the serial number);


4.4

Instruction manual

Each apparatus shall be provided with an instruction manual that includes the following
information:
a) complete instructions, drawings and diagrams for safe and proper operation, installation
and servicing of the apparatus,
b) operating instructions and adjustment procedures,
c) recommendations for initial checking and calibration of the apparatus on a routine basis,
including instructions for the use of the field calibration kit, if provided (see also 5.4.26).
For portable apparatus, these shall include the requirement and method for performing a
functional check with gas before each day of use;
NOTE-

Users are referred to IEC 60079-29-2.

d) details of operational limitations including, where applicable, the following:


1)

gases for which the apparatus is suitable and the relative sensitivities to these
gases,

2)

information that describes the sensitivities to other gases to which the apparatus is
responsive,

3)

response times t (90) for the standard test gas(es), and information that describes
how response times could vary for other gases,

4)

temperature limits,

5)

humidity ranges,

6)

pressure limits,

7)

supply voltage limits,

8)

maximum power consumption,

9)

relevant characteristics and construction details of required interconnecting cables,

10)

battery data,

11)

sample flow rate,

12)

warm-up time,

13) stabilization time,


e) details of storage life and limitations for the apparatus, replacement parts and
accessories, including, where applicable, the following:

f)

1)

temperature,

2)

humidity,

3)

pressure,

4)

time,

bases used for converting test and calibration gas concentrations from % LFL to % volume
fraction;

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

22

60079-29-1 IEC:2007

g) information on the adverse effects of poisons and interfering gases or substances and
oxygen-enriched or deficient atmospheres on the proper performance (and, in the case of
oxygen-enriched atmospheres, on electrical safety) of the apparatus;
h) for aspirated apparatus, indication of the minimum and maximum flow rates and pressure;
also, tubing type, maximum length and size for proper operation;
i)

for aspirated apparatus, instructions for ensuring that the sample lines are intact and that
proper flow is established (see 4.2.4);

j)

statements of the nature and significance of all alarms and fault signals, the duration of
such alarms and signals (if time-limited or non-latching), and any provisions that may be
made for silencing or resetting such alarms and signals, as applicable;

l)

a statement that alarm devices, outputs or contacts are of the non-latching types, where
applicable (see 4.2.3.2);

m) for battery-operated apparatus, installation and maintenance instructions for the batteries;
n) a recommended replacement parts list;
o) where optional accessories (e.g. collecting cones, weather-protecting devices) are
supplied, the manufacturer shall list such accessories and state their effects on the
instrument characteristics (including response time and sensitivity), and provide means for
their identification (e.g. part numbers included in manual);
p) details of certification and marking, and any special conditions of service;
q) where the special nature of the apparatus (such as non-linear responses) requires
additional instructions or special information that are alternative to, or in addition to, the
requirements of 4.3 and 4.4 a) to p), the instructions or information shall be provided.

Test methods

5.1

Introduction

The test methods and procedures described in 5.2 to 5.4 are intended as a basis for
establishing whether the apparatus conforms with the supplementary requirements for
performance given in Annex A.
5.2

General requirements for tests

Where it is necessary to apply LFL and UFL values for the purposes of this standard, they
shall be taken from IEC 60079-20.
5.2.1
5.2.1.1

Samples and sequence of tests


General

For the purpose of type testing, the tests shall be carried out on one apparatus. Another
apparatus may be used for tests according to 5.4.4.2 to 5.4.4.5, 5.4.18 and 5.4.24.
For IR-sensors using optical filters, the test 5.4.3.3 shall be conducted with two apparatus
where the centre wavelength of the optical filters shall be at the minimum and maximum limits
of the specification. One of these units may be used subsequently for 5.4.4.2 to 5.4.4.5,
5.4.18 and 5.4.24.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

k) details of any method for the determination of the possible sources of a malfunction and
any corrective procedures (i.e. trouble-shooting procedures);

60079-29-1 IEC:2007
5.2.1.2

23

Sequence

The apparatus shall be subjected to all of the tests applicable to that type of apparatus, as
described in 5.4.
Test 5.4.2 shall be conducted prior to all other tests. The manufacturer may request a
particular order of the other tests. However, the tests 5.4.4.2 to 5.4.4.5, 5.4.18, and 5.4.24
shall always be conducted in this sequence.
5.2.1.3

Stand alone gas detection apparatus

Stand alone gas detection apparatus shall be tested to the requirements of 5.4.2 through
5.4.13, 5.4.15, 5.4.16, 5.4.18, 5.4.20 through 5.4.27 (if applicable) using the parameters of
the transfer function.
5.2.1.4

Stand alone control units

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Stand alone control units shall be tested to the requirements of 5.4.2, 5.4.3, 5.4.6, 5.4.7,
5.4.13, 5.4.15, 5.4.16, 5.4.18, 5.4.20, 5.4.21, 5.4.25 and 5.4.27 using the parameters of the
transfer function pertinent to the specific type of gas detector.
5.2.1.5

Sample

Tests shall also be carried out, where applicable, to ensure that the apparatus satisfies the
construction requirements of 4.2. The requirements for these tests are generally self-evident,
except that for short-circuit requirements in 4.2.4, ballast resistors shall be substituted for
each wire connecting the instrument to any remote sensor. The values of these resistors shall
be those declared, in the instruction manual (see 4.4 d)), to be the maximum lead resistances
allowing satisfactory compliance with the standard. The device used for the short circuit shall
be of negligible resistance and shall be applied to convenient points in the circuit, at the
sensor ends of the ballast resistors.
5.2.1.6

Sample with selectable range

For apparatus having more than one selectable range or scale for the same or different gases
or vapours, each range shall be tested. For the second and subsequent ranges the necessary
amount of testing shall be agreed upon between the manufacturer and the test laboratory.
5.2.2

Preparation of apparatus before testing

The apparatus shall be prepared and mounted as near to typical service as possible, in
accordance with the instruction manual, including all necessary interconnections, initial
adjustments and initial calibrations. Adjustments may be made, where appropriate, at the
beginning of each test.
In particular, the following points shall be noted:
a) Apparatus having remote sensors
For the purpose of the tests in 5.4, where reference is made to exposure of the sensor to
the test conditions, the entire remote sensor (including any or all normally attached
protective mechanical parts) shall be exposed.
For apparatus having connection facilities for more than one remote sensor, only one
remote sensor needs to be subjected to the tests. The replacement of all but one sensor
by "dummy" impedances yielding the worst case load conditions for the test in question
shall be permitted. The worst case load conditions shall be determined by the testing
laboratory within the limits specified in the instruction manual (see 4.4 d)).

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

24

60079-29-1 IEC:2007

For apparatus having remote sensor(s), all tests shall be performed with resistances
connected in the detector circuit to simulate the maximum line resistance specified by the
manufacturer, except where minimum line resistance offers a more stringent test in the
judgement of the test laboratory.
b) Apparatus having self-contained sensors
The entire apparatus shall be exposed to the test conditions without removal of any
normally attached parts, including any sampling probe for tests 5.4.11, 5.4.15, 5.4.16 and
5.4.17.
c) Alarm-only apparatus
For alarm-only apparatus, readings shall be taken using an external meter connected to
the test points described in 4.2.2.2.
In all cases, optional parts shall be either attached or removed according to which condition
will give the most unfavourable result (at the discretion of the testing laboratory) for the test
being conducted.
5.2.3

Mask for calibration and tests

When a mask is used for calibration or for the injection of test gas into the sensor, the design
and operation of the mask used by the testing laboratory in particular the pressure and
velocity inside the mask shall not inadmissibly influence the response of the apparatus or
the results obtained.
NOTE It is recommended that the testing laboratory should consult with the manufacturer in determining the
design of the calibration mask. The manufacturer may provide a suitable calibration mask together with details of
suggested pressure or flow for application of calibration gases with the apparatus.

5.3
5.3.1

Normal conditions for test


General

The test conditions specified in 5.3.2 to 5.3.12 shall be used for all tests, unless otherwise
stated.
5.3.2

Test gas(es)

The flammable gas(es) to be used in a mixture with clean air for initial and all subsequent
tests shall be selected in accordance with a) to c) with decreasing priority below.

b) Methane for apparatus intended for sensing methane or firedamp, or intended for general
purpose flammable gas detection that includes the detection of methane.
c) A gas from the range of flammable gases for which the apparatus is deemed to be suitable
by the manufacturer. The choice of this gas should be made by agreement between the
manufacturer and the test laboratory.
NOTE 1 It is recommended to test apparatus with catalytic combustion sensors intended for general purpose gas
detection including methane with test gases methane and propane in order to get representative results (e.g.
concerning sensitivity, response times and drift).
NOTE 2 It is recommended to test apparatus with IR-sensors intended for general purpose gas detection of
hydrocarbons including methane with test gases methane and propane in order to get representative results (e.g.
concerning sensitivity).

For all the other gases for which the apparatus is claimed to be suitable, the calibration
curves and response times shall be supplied by the manufacturer and a representative
sample verified by the testing laboratory. The volume fraction of the component within the test
gas(es) shall be known to a relative expanded uncertainty of 2 % of the nominal value.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

a) The specific gas for apparatus intended for sensing a single flammable gas only.

60079-29-1 IEC:2007

25

NOTE 3 For the purpose of this standard, where it is appropriate to use zero gas rather than clean air, references
to clean air may be regarded as references to zero gas.
NOTE 4 The gas mixture may be prepared by any suitable method, for example in accordance with the methods
outlined in ISO 6142 or ISO 6145 , or by commercially produced certified gas mixtures .

5.3.3

Standard test gas

The volume fractions of the standard test gases shall be as follows:


a) for group I apparatus indicating up to a volume fraction of 5 % methane: equivalent range
of either a volume fraction of (1,5 0,15) % or a volume fraction of (2,0 0,2) %, as
agreed between the manufacturer and the testing laboratory;
b) for other group I and all group II apparatus: 45 % to 55 % of the measuring range, not
within the explosive range wherever possible. If this concentration is within the explosive
range, the flammable gas shall be mixed with nitrogen if the measuring function of the
apparatus is not affected by oxygen deficiency. Otherwise the concentration of the
standard test gas shall be taken outside the explosive range as near as possible to the
values stated above;
The volume fractions shall be known to a relative expanded uncertainty of 2 %.
5.3.4

Flow rate for test gases

When the apparatus is exposed to the test gases, including air, the flow rate of the gas shall
be in accordance with the manufacturer's instructions.
NOTE For apparatus that samples by diffusion, either a calibration mask in accordance with 5.2.3 or a test
chamber may be used (see also Annex B).

5.3.5

Voltage

a) Mains-powered and fixed DC powered apparatus shall be operated within 2 % of the


manufacturer's recommended supply voltage and frequency.
b) Battery-powered apparatus shall, for short-term tests, be equipped with new or fully
charged batteries at the commencement of each series of tests. For long-term testing, it is
permissible to energize the unit from a stabilized power supply.
5.3.6

Temperature

The ambient air and test gas shall be held at a temperature constant to 2 K within the range
of 15 C to 25 C, throughout the duration of each test, unless otherwise specified for the
particular test.
5.3.7

Pressure

The tests shall be performed at pressures between 86 kPa and 108 kPa with a maximum
variation of 1 kPa throughout the duration of each short-term test, unless otherwise specified
for the particular test. For long-term tests, the influence of pressure changes shall be taken
into account, using the results of the pressure test (5.4.8).
5.3.8

Humidity

The ambient air and test gas shall be held at a relative humidity (RH), controlled to within
10 % RH, over the range 20 % to 80 % throughout each test unless otherwise specified for
the particular test.
For short applications of test gases, the use of dry gases is permitted. The properties of the
measuring principle of the sensor shall be taken into account.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

26
5.3.9

60079-29-1 IEC:2007

Stabilization time

In each instance where the apparatus is subjected to a different test condition, the apparatus
shall be allowed to stabilize under these new conditions before measurements are taken.
5.3.10

Orientation

The apparatus shall be tested in the orientation recommended by the manufacturer.


5.3.11

Communications options

For apparatus having serial or parallel communications options used during normal gas
detection operation, tests in 5.4.3, 5.4.7 and 5.4.16 shall be performed with all communication
ports connected. The maximum transaction rate, cabling characteristics and activity level
specified by the instruments manufacturer shall be employed.
5.3.12

Gas detection apparatus as part of systems

For gas detection apparatus, which are part of systems, tests in 5.4.3, 5.4.7, 5.4.16 and
5.4.20 shall be performed with the maximum system communications transaction rate and
activity level. This shall correspond to the largest and most complex system configuration
permitted by the manufacturer.
5.4

Test methods

5.4.1

General

5.4.2

Unpowered storage

All parts of the apparatus shall be exposed sequentially to the following conditions in clean air
only:
a) a temperature of (25 3) C for 24 h;
b) ambient temperature for at least 24 h;
c) a temperature of (60 2) C for 24 h;
d) ambient temperature for at least 24 h.
At each temperature, the humidity of the clean air shall be so that condensation does not
occur.
The above temperatures may be varied only after an agreement has been reached between
the manufacturer and testing laboratory (see also 4.1.2). Where temperatures other than
those listed above are used, they shall be listed in the certification documents.
5.4.3
5.4.3.1

Calibration and adjustment


Initial preparation of the apparatus

The apparatus shall be calibrated and adjustments shall be carried out, if needed, to obtain
correct indications in accordance with the manufacturer's instruction manual.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

The following tests shall be performed in accordance with 5.3, unless otherwise stated. All
tests shall be performed. At the end of each test, indications shall be taken in both clean air
and the standard test gas, unless otherwise stated. The values of the indications used for
verification of compliance with the performance requirements of Annex A shall be the final
indications (see 3.6.2) of both the clean air and standard test gas readings, unless otherwise
stated.

60079-29-1 IEC:2007
5.4.3.2

27

Calibration curve

The apparatus shall be exposed to the gas selected in accordance with 5.3.2, at four volume
fractions evenly distributed over the measuring range, starting with the lowest and finishing
with the highest of the selected volume fractions. This operation shall be carried out three
times consecutively.
5.4.3.3

Response to different gases

For group II apparatus, the accuracies of the response curves or correction charts provided in
the manufacturer's manual shall be checked by measuring the response for the representative
gases according to 5.3.2, at a minimum of three different volume fractions spread evenly over
the measuring range to verify response characteristics.
The ratio between the indication of the apparatus (before correction using the manufacturers
response curve or correction charts) and the gas volume fraction obtained for each of the
three gas volume fractions of each gas tested shall not be less than 0,4 and shall not exceed
2,0.
5.4.4

Stability (continuous duty apparatus only)

NOTE For these tests, battery-powered apparatus should be powered from internal batteries wherever possible,
otherwise an external power supply may be used.

5.4.4.1

Short-term stability

The apparatus shall be exposed to six applications of the standard test gas for 3 min followed
by exposure to clean air for a period of 7 min. Indications shall be taken at the end of each
exposure to air and the standard test gas.
5.4.4.2

Long-term stability (fixed and transportable apparatus Group I only)

The apparatus shall be operated in clean air continuously for a period of four weeks and shall
be exposed to the standard test gas for an 8 h period at weekly intervals over the four-week
period. Indications shall be taken prior to the application of, after stabilization and prior to
removal of the standard test gas.
Following this period, the following test shall be performed.
The apparatus shall be run in a methane-air mixture with a volume fraction of 1,0 % (v/v)
0,05 % (v/v) for 5 days, indications being taken daily in clean air and the standard test gas.
5.4.4.3

Long-term stability (portable apparatus Group I only)

The apparatus shall be operated in clean air continuously for a period of 8 h per working day
over a total of 20 working days. The apparatus shall be exposed to the standard test gas for
1 h during each operating period. Indications shall be taken prior to the application of, after
stabilization, and prior to removal of the standard test gas.
Following this period, the following test shall be performed.
The apparatus shall be operated in a methane-air mixture with a volume fraction of 1,0 % (v/v)
0,05 % (v/v) for 8 h, taking indications in clean air and the standard test gas at the end of
this period. The apparatus shall then be switched off and exposed to clean air for 16 h. This
cycle shall be repeated a further 4 times.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

28
5.4.4.4

60079-29-1 IEC:2007

Long-term stability (fixed and transportable apparatus Group II only)

The apparatus shall be operated continuously in clean air for a period of two months. At the
end of the first week, the apparatus shall be exposed to the standard test gas for an 8 h
period. Indications shall be taken prior to the application of test gas, after stabilization of the
reading and prior to the removal of test gas.
At the end of each subsequent week, the apparatus shall be exposed to the standard test gas
until the reading has stabilized. Indications shall be taken prior to both the application and the
removal of the test gas.
5.4.4.5

Long-term stability (portable apparatus Group II only)

The apparatus shall be operated in clean air continuously for a period of 8 h per working day
over a total of 20 working days. The apparatus shall be exposed to the standard test gas until
stabilized, once during each operating period. Indications shall be taken prior to the
application of, after stabilization and prior to removal of the standard test gas.
5.4.5

Stability (spot-reading apparatus only)

The apparatus shall be exposed to clean air for 1 min followed by the standard test gas for
1 min. The operation shall be repeated 200 times. The final indication will be taken in clean
air and the standard test gas, after stabilization at the end of the test.
NOTE For these tests, battery-powered apparatus should be powered from internal batteries wherever possible,
otherwise an external power supply may be used.

5.4.6
5.4.6.1

Alarm set point(s)


General

When the apparatus is provided with either


a) externally adjustable means of setting either one or more alarm set points, or
b) internally pre-set alarm point(s) the activation of such alarms by gas at the appropriate set
point values shall be verified by using test gases as described in 5.4.6.2 and 5.4.6.3. In all
cases, the test gas shall be applied until either activation of the alarm(s) or twice the
respective t (90), whichever is less.
For apparatus with several alarm set points, these tests shall be carried out for each alarm
set point.
5.4.6.2

Increasing concentration

For apparatus of type a) set the alarm set point at 10 % relative below the concentration of
the standard test gas. If the alarm set point cannot be set at this concentration the alarm shall
be set as near as possible to that concentration. In this case and for apparatus of type b), the
test gas shall have a volume fraction of 10 % relative above the concentration of the alarm set
point. Expose the apparatus to clean air and then to the standard test gas or the specified test
gas.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007
5.4.6.3

29

Decreasing concentration

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

For apparatus of type a) set the alarm set point at 5 % of the measuring range. If the alarm
set point cannot be set at this concentration the alarm shall be set as near as possible to that
concentration. In this case and for apparatus of type b), the test gas shall have a volume
fraction of the alarm set point minus 5 % of the measuring range. Expose the apparatus to
standard test gas and then to clean air or the specified test gas.
5.4.7

Temperature

This test shall be performed in a temperature chamber having the capability of holding the
sensor or apparatus at the specified temperature within 2 C. When the apparatus (or the
portion under test) has reached the temperature specified in Annex A, as appropriate, the
sensor shall be exposed sequentially to air and the standard test gas, which shall be at the
same temperature as the atmosphere in the test chamber. The dew point of the air or
standard test gas shall be below the lowest temperature of the test chamber and kept
constant during the test.
5.4.8

Pressure

The effects of pressure variation shall be observed by placing the sensor or apparatus
(including the aspirator for aspirated apparatus) in a test chamber that permits the pressure of
clean air and of the standard test gas to be varied.
The pressure shall be maintained at the specified levels for 5 min, before a reading is
accepted or a test is made. Readings shall be taken with clean air and standard test gas.
5.4.9

Humidity

The test shall be done with three different humidities evenly distributed over the range
specified in Annex A. The apparatus shall be allowed to stabilize at 40 C. After stabilization it
shall be adjusted according to the instructions of the manufacturer. For each humidity, the
apparatus shall be exposed for 15 min to clean air and then to the standard test gas at the
same humidity. The relative humidity levels shall be known to within 3 % RH.
The concentration of the test gas shall be held constant, or due allowance of changes in its
concentration by dilution in water shall be made.
5.4.10

Air velocity

5.4.10.1

General

The effects of air speed over a range of 0 m/s to 6 m/s on apparatus with sensors that operate
by diffusion shall be determined using the test conditions given in 5.4.10.2.
5.4.10.2

Test conditions

The separate sensors of apparatus with remote sensors and, when practicable, the entire
apparatus if the sensors are integral shall be tested in a flow chamber.
NOTE

The flow chamber should be suitable for the application of clean air and the standard test gas.

For apparatus having integral sensors, which are too large to be tested in a flow chamber,
other flow apparatus for carrying out the test shall be permitted.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

30

60079-29-1 IEC:2007

Irrespective of whether a flow chamber or other flow apparatus is used, orient the sensor in
relation to the direction of the air flow as follows:
1) sensor oriented directly towards direction of flow,
2) sensor oriented away from the direction of flow,
3) sensor oriented at right angles to the direction of flow.
Measurements shall be made under static conditions, at 3 m/s and at 6 m/s.
NOTE Directions of flow which are not likely to occur in practice, due to the design of the apparatus, or which are
expressly prohibited within the manufacturers instruction manual may not be tested.

5.4.11

Flow rate for aspirated apparatus

The apparatus shall be tested by varying the flow rate


1) from 130 % of the nominal flow rate or, if this is not possible, from the nominal flow rate,
2) to the flow rate at which the failure alarm is set, or to 50 % of the nominal flow rate if no
failure alarm is provided.
5.4.12
5.4.12.1

Orientation
Portable apparatus

During tests with clean air and standard test gas, rotate the sensor, or the whole apparatus if
relevant, through 360 in steps of 90 around each of its three mutually perpendicular axes
(one axis at a time). Record the indication in each position.
5.4.12.2

Fixed and transportable apparatus

Test the sensor, or the apparatus having an integral sensor, with clean air and standard test
gas within the orientation limits stated in the manufacturer's instructions, but in no case less
than a deviation of 15 from the nominal orientation.
5.4.13
5.4.13.1

Vibration
Test equipment

The vibration test machine shall consist of a vibrating table capable of producing a vibration of
variable frequency and variable constant displacement (peak-to-peak), with the test apparatus
mounted in place, as required by the following test procedures.
5.4.13.2

Procedures

The apparatus shall be energized and mounted on the vibration test machine and vibrated
successively in each of three planes respectively parallel to each of the three major axes of
the apparatus.
The alarm set point shall be set to 20 % of full-scale range.
Before, and at the conclusion of the test, the apparatus shall be exposed to clean air followed
by the standard test gas.
The apparatus shall be mounted on the vibration table in the same manner as intended for
service use including any resilient mounts, carrier or holding devices that are provided as
standard parts of the apparatus.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

31

The apparatus shall be vibrated over the frequency range specified at the excursion or
constant acceleration peak specified, for a period of 1 h in each of the three mutually
perpendicular planes. The rate of change of frequency shall not exceed 10 Hz/min.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5.4.13.2.1

Procedure 1

For portable and transportable apparatus, remote sensors, and controllers where the sensor
is integral with or directly attached to the controller, the vibration shall be as follows:
10 Hz to 30 Hz, 1,0 mm total excursion,
31 Hz to 150 Hz, 19,6 m/s 2 acceleration peak.
5.4.13.2.2

Procedure 2

For control units intended to be installed remotely from the sensor, the vibration shall be as
follows:
10 Hz to 30 Hz, 1,0 mm total excursion,
31 Hz to 100 Hz, 19,6 m/s 2 acceleration peak.
5.4.14

Drop test for portable and transportable apparatus

This test is applicable to portable apparatus and transportable apparatus. If the manufacturer
recommends that the instrument be used in its carrying case, the test shall be carried out with
the case only.
NOTE If components of fixed apparatus can be used like portable or transportable apparatus according to the
instruction manual, these components should be considered to be portable or transportable for this test.

Before, and at the conclusion of the test, the apparatus shall be exposed to clean air followed
by the standard test gas.
Portable apparatus shall be released, while operating, from a height of 1 m above a concrete
surface and allowed to free fall.
Transportable apparatus with a mass less than 5 kg shall be released, while not operating,
from a height of 0,3 m above a concrete surface and allowed to free fall.
Other transportable apparatus shall be released, while not operating, from a height of 0,1 m
above a concrete surface and allowed to free fall.
The test required above shall be performed three separate times, the portable apparatus
being released each time with a different side (surface) facing down at the time of release and
the transportable apparatus to be in an orientation for normal transport.
The apparatus shall be considered to have failed this test if there is a loss of function (e.g.
alarm, pump function, controls, display) after the test.
5.4.15

Warm-up time

The alarm set point shall be set to 20 % of the measuring range.


The apparatus shall be switched off and left for 24 h in clean air. After the 24 h period, the
apparatus shall be switched on in clean air and the warm-up time measured.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

32

60079-29-1 IEC:2007

Group I apparatus, except spot-reading apparatus, shall be switched off for a further 24 h in
clean air. After this period, the apparatus shall be exposed for 5 min to the standard test gas,
then switched on in the presence of the test gas and the warm-up time measured.
5.4.16

Time of response (not applicable to spot-reading apparatus)

The apparatus shall be switched on in clean air and, after an interval corresponding to at least
two times the warm-up time, as determined in accordance with 5.4.15, without switching off,
the apparatus or the sensor(s) shall be subjected to step changes from clean air to the
standard test gas and from standard test gas to clean air. These changes shall be introduced
by means of suitable equipment (see Annex B).
The times of response t (50) and t (90) for increasing concentration, and t (50) and t (10) for
decreasing concentration shall be measured.
The times of response shall apply to the apparatus in the as supplied condition and without
optional accessories, e.g. collecting cones, weather protection, attached to the sensor for
special purposes.
For an optional sampling probe, an extra test is required to measure the additional delay. This
shall be less than 3 s/m of the total length of the probe plus tubing or any greater value, which
is stated in the instruction manual.
5.4.17

Minimum time to operate (spot-reading apparatus)

The standard test gas shall be applied to the apparatus simultaneously with the initiation of
the measurement procedure.
Clean air shall than be applied to the apparatus simultaneously with the initiation of the
measurement procedure.
5.4.18

High gas concentration operation above the measuring range

This subclause applies to all apparatus with an upper limit of the measuring range less than
100 % (v/v) gas.
The entire apparatus, or the remote sensors of fixed or transportable apparatus, shall be
subjected to the test given in 5.4.18.1 or 5.4.18.2 using a test apparatus that simulates a step
change between gas concentrations such as those described in Annex B.
All gas concentrations above full scale shall be indicated by a full scale meter indication and,
where fitted, an alarm. If the indication is digital, a clear indication shall be given that the
upper limit of the measuring range has been exceeded.
5.4.18.1

Spot-reading apparatus

The apparatus shall be subjected to 50 cycles, each cycle being an exposure of a volume
fraction of 100 % (v/v) gas for the minimum time of operation, followed by exposure to clean
air for the minimum time of operation. Following the final cycle, five operations in clean air
shall be made, each operation equivalent to the minimum time of operation, and the
apparatus shall then be subjected to the standard test gas.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007
5.4.18.2

33

Apparatus other than spot-reading apparatus

The apparatus, or remote sensor, shall be subjected to a step change from clean air to a
volume fraction of 100 % gas that shall be maintained for 3 min. The sensor shall then be
subjected to clean air for 20 min, followed by the standard test gas.
5.4.19

Battery capacity

5.4.19.1

Battery-powered portable continuous duty apparatus

5.4.19.1.1

Battery discharge

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

With a battery fully charged at the beginning of the test, the apparatus shall be operated in
clean air for a total period of
a) 8 h, if fitted with a user-operable on/off switch,
b) 10 h, if not so fitted, or
c) any longer time as specified by the manufacturer.
At the end of the specified period, the apparatus is exposed to the standard test gas.
5.4.19.1.2

Low battery duration

The apparatus shall then continue to operate until an indication that the low battery condition
has been reached. The apparatus shall continue to operate for an additional 10 min.
5.4.19.2

Battery-powered portable spot-reading apparatus

5.4.19.2.1

Battery discharge

With the battery fully charged at the beginning of the test, the apparatus shall be operated in
clean air 200 times.
The duration of each operation shall be equal to the minimum time of operation; 1 min shall
elapse after each operation.
At the end of the 200 operations, the apparatus shall be exposed to the test gas.
5.4.19.2.2

Low battery discharge

The cycle of operations shall then be continued until an indication that the low battery
condition has been reached. The apparatus shall be operated for an additional 10 times.
5.4.20

Power supply variations

The apparatus shall be set up under normal conditions (see 5.3), at nominal supply voltage
and, where appropriate, rated frequency. For apparatus with remote sensors, the test shall be
performed with both maximum and minimum resistance of the interconnecting cable. The
apparatus shall then be subjected to the following tests.
The apparatus calibration shall be checked at both 115 % and 80 % of nominal supply
voltage.
Where the manufacturer of the apparatus specifies a supply range other than those specified
above, the apparatus shall be tested at the upper and lower limits of the supply voltage
specified by the manufacturer.
It shall be verified at the minimum supply voltage that all output functions are working properly
even at the maximum load conditions.
Copyright International Electrotechnical Commission
Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

34

60079-29-1 IEC:2007

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

NOTE 1

This includes testing of analogue outputs at the maximum load and maximum current.

NOTE 2

This includes testing that relays are able to energize at the minimum supply voltage.

5.4.21
5.4.21.1

Power supply interruptions, voltage transients and step changes of voltage


General

The apparatus shall be set up under normal conditions, in accordance with 5.3, and then shall
be subjected to the tests specified in 5.4.21.2 to 5.4.21.4 in clean air only.
The alarm set point shall be set to 20 % of the measuring range.
5.4.21.2

Short interruption of power supply

The power supply shall be interrupted for 10 ms, repeated 10 times at random time intervals
having a mean value of 10 s.
5.4.21.3

Voltage transients

The apparatus shall be tested according to IEC 61000-4-4, test severity 2. The test procedure
for type tests performed in laboratories shall be used. The test duration shall be 1 min for
each line or terminal to be tested.
5.4.21.4

Step changes of voltage without interruption

For a.c. and external d.c. powered apparatus, the power voltage shall be increased by 10 %,
maintained at this value until the apparatus is stabilized, and then reduced to 15 % below
nominal voltage. Each step change shall take place within 10 ms.
5.4.22

Addition of sampling probe

When it is intended to add a sampling probe, the apparatus shall first be calibrated using
clean air and the standard test gas without the sampling probe. The sampling probe shall then
be added, and clean air and standard test gas applied again.
5.4.23

Dust (for apparatus where the air is sampled by natural diffusion only)

The effect of dust shall be simulated by uniformly reducing the gas inlet area of the apparatus
by 50 % before subjecting it to clean air or the standard test gas.
5.4.24
5.4.24.1

Poisons and other gases


Poisons (applicable only to group I apparatus with catalytic or
semiconductor sensors)

The apparatus shall be exposed to a volume fraction of 1 % methane in air mixture containing
a volume fraction of 10 10 - 6 of hexamethyldisiloxane and shall perform 40 min continuous
operation for continuous duty apparatus, or 100 tests for spot-reading apparatus.
Certain materials that may be present in industrial atmospheres can lead to "poisoning" or
other undesirable effects which may result in a change of sensitivity of a gas sensor.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

35

NOTE As improved tolerances to these materials are frequently claimed by manufacturers, evidence of the testing
procedure used to substantiate these claims and test results may be open to validation or verification by agreement
between a purchaser, a manufacturer, and a testing laboratory. Possible "poisoning" agents and their effects on
sensor performance are discussed in IEC 60079-29-2.

5.4.24.2

Other gases

The apparatus shall be tested separately with the following gas mixtures:
a) group I apparatus indicating up to a volume fraction of 5 % methane in air:
1) a methane volume fraction of the standard test gas + a volume fraction of 13 % oxygen
in nitrogen,
2) a methane volume fraction of the standard test gas + a volume fraction of 5 % carbon
dioxide in air,
3) a methane volume fraction of the standard test gas + a volume fraction of 0,075 %
ethane in air,
b) group I apparatus indicating up to a volume fraction of 100 % methane:
1) a volume fraction of 50 % methane + a volume fraction of 6,5 % oxygen in nitrogen,
2) a volume fraction of 50 % methane + a volume fraction of 5 % carbon dioxide in nitrogen,
3) a volume fraction of 50 % methane + a volume fraction of 2,5 % ethane in nitrogen.
The gas mixtures may be prepared by any suitable method. The tolerances on the volume
fraction of each component shall be within 10 % of its nominal concentration.
The volume fraction of each component shall be known to a relative expanded uncertainty of
2 % of the stated value.
5.4.25

Electromagnetic immunity

The apparatus, including the sensor and interconnecting wiring, shall be subjected to a test
method used in conducting EMC radiated immunity tests according to IEC 61000-4-1 and
IEC 61000-4-3.
The test requirements shall be carried out with severity level 2; test field strength 3 V/m.
NOTE More severe electromagnetic immunity test parameters may be required for specific applications or for
local regulations.

The alarm set point shall be set to 20 % of measuring range.


The test shall be carried out in clean air.
In the case of field systems with remote sensing where the control unit is intended for general
purpose rack mounting or its equivalent, such a control unit shall be submitted to these tests
in an enclosure supplied by the manufacturer.

NOTE

Electromagnetic emission requirements may be required by other standards.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

The instruction manual shall inform the user that such apparatus is to be used with the same
enclosure to avoid adverse electromagnetic effects.

36
5.4.26

60079-29-1 IEC:2007

Field calibration kit

If a field calibration kit is provided with the apparatus, carry out the following test:
a) calibrate the apparatus in accordance with 5.4.3.1 using the test conditions given in 5.3
and using the test equipment for the tests described in 5.4,
b) use the field calibration kit in a manner corresponding to the manufacturer's instructions
for checking the apparatus response.
5.4.27

Software verification

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

The function of the software-controlled apparatus shall be evaluated and tested according to
4.2.9.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Unpowered storage

Calibration curve

Response to other
gases

Stability, short term

Stability, long term


(fixed/transportable)

Stability, long term


(portable)

Stability
(spot-reading apparatus
only)

Alarm set point(s)

Temperature
(portable/transportable)

5.4.3.2

5.4.3.3

5.4.4 (a)

5.4.4 (b)

5.4.4 (c)

5.4.5

5.4.6

5.4.7 (a)

Test

5.4.2

Subclause

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

0,2 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Check alarm/manual reset


operation

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication

Not applicable

0,1 % methane or
5 % of indication

None

5 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Check alarm/manual reset


operation

3 % methane or
5 % of indication

3 % methane or
5 % of indication

3 % methane or
5 % of indication

3 % methane or
5 % of indication

Not applicable

3 % methane or
5 % of indication

None

Volume fraction up to 100 %


methane in air indication

Volume fraction up to 100 %


gas indication

5 % measuring range or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Check alarm/manual reset


operation

3 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication

7 % measuring range or
20 % of indication

3 % measuring range or
10 % of indication

7 % measuring range or
15 % of indication

5 % measuring range or
10 % of indication

None

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5 % measuring range or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Check alarm/manual reset


operation

5 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication

7 % measuring range or
20 % of indication

3 % measuring range or
10 % of indication

7 % measuring range or
15 % of indication

5 % measuring range or
10 % of indication

None

Volume fraction up to 100 %


lower flammable limit indication

(whichever value is greater)

(whichever value is greater)

Volume fraction up to 5 %
methane in air indication

Group II apparatus limits

Group I apparatus limits

Table A.1 Performance requirements

Performance requirements

Annex A
(normative)

60079-29-1 IEC:2007
37

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Humidity

Air velocity

Flow rate

Orientation

5.4.10

5.4.11

5.4.12

Pressure

(fixed with sensor)

Temperature

(fixed with remote


sensor)

Temperature

Test

5.4.9

5.4.8

5.4.7(c)

5.4.7 (b)

Subclause

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication

0,2 % methane or
15 % of indication from the
indication at adjustment at
40 C
(test: 20 %RH, 50 %RH,
90 %RH)

0,2 % methane or
30 % of indication from
100 kPa
(test: 80 kPa, 100 kPa,
120 kPa)

0,2 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

0,2 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Volume fraction up to 5 %
methane in air indication

5 % measuring range or
10 % of indication

Portable:

3 % methane or
5 % of indication

Fixed/transportable:

5 % methane or
10 % of indication

5 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication

10 % measuring range or
30 % of indication from the
indication at adjustment at 40 C
(test: 20 %RH, 50 %RH, 90 %RH)

5 % measuring range or
30 % of indication from 100 kPa
(test: 80 kPa, 100 kPa, 120 kPa)

5 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication

10 % measuring range or
30 % of indication from the
indication at adjustment at 40 C
(test: 20 %RH, 50 %RH, 90 %RH)

5 % measuring range or
30 % of indication from 100 kPa
(test: 80 kPa, 100 kPa, 120 kPa)

5 % measuring range or
15 % of indication from 20 C
(test: 10 C, 20 C, 55 C)

Control unit:
3 % measuring range or
10 % of indication from 20 C
(test: 5 C, 20 C, 55 C)

Control unit:
3 % measuring range or
10 % of indication from 20 C
(test: 5 C, 20 C, 55 C)
5 % measuring range or
15 % of indication from 20 C
(test: 10 C, 20 C, 55 C)

10 % measuring range or
20 % of indication from 20 C
(test: 25 C, 20 C, 55 C)

Sensor:

Volume fraction up to 100 %


gas indication

10 % measuring range or
20 % of indication from 20 C
(test: 25 C, 20 C, 55 C)

Sensor:

Volume fraction up to 100 %


lower flammable limit indication

3 % methane or
5 % of indication

3 % methane or
5 % of indication

5 % methane or
15 % of indication from the
indication at adjustment at
40 C
(test: 20 %RH, 50 %RH,
90 %RH)

5 % methane or
30 % of indication from
100 kPa
(test: 80 kPa, 100 kPa,
120 kPa)

5 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

5 % methane or
10 % of indication from 20 C
(test: 10 C, 20 C, 40 C)

Volume fraction up to 100 %


methane in air indication

Group II apparatus limits


(whichever value is greater)

Group I apparatus limits


(whichever value is greater)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Table A.1 (continued)

38
60079-29-1 IEC:2007

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

High gas concentration


operation above the
measuring range

5.4.18

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

0,2 % methane or
+20 % / 10 % of indication

Indication at 90 % final value in


less than 30 s in either gas

t (10) in less than 90 s

(decreasing
concentration)

Minimum time to
operate

t (50) in less than 30 s

Time of response

5.4.17

5.4.16

5 % methane or
10 % of indication

Indication at 90 % final value in


less than 30 s in either gas

t (10) in less than 30 s

t (50) in less than 10 s

t (90) in less than 30 s

t (50) in less than 10 s

3 % methane within 2 min,


and no false alarm

0,1 % methane within 2 min,


and no false alarm

t (90) in less than 30 s

Continuous duty portable:

Continuous duty portable:

t (50) in less than 10 s

3 % methane within 5 min,


and no false alarm

0,1 % methane within 5 min,


and no false alarm

7 % measuring range or
+20 % / 10 % of indication

Indication at 90 % final value in


less than 30 s in either gas

Not applicable

t (90) in less than 60 s

t (50) in less than 20 s

5 % measuring range within


2 min, and no false alarm

Continuous duty portable:

5 % measuring range within


manual spec., and no false alarm

Fixed/transportable:

Fixed/transportable:

Fixed/transportable:

Time of response

Warm-up time

5.4.15

5 % measuring range or
10 % of indication, and no loss of
function, no fault signal, no
damage resulting in a hazard and
no false alarms

Volume fraction up to 100 %


lower flammable limit indication

5 % measuring range or
10 % of indication

3 % methane or
5 % of indication, and no loss
of function, no fault signal, no
damage resulting in a hazard
and no false alarms

Volume fraction up to 100 %


methane in air indication

3 % methane or
5 % of indication

0,1 % methane or
5 % of indication

0,1 % methane or
5 % of indication, and no loss
of function, no fault signal, no
damage resulting in a hazard
and no false alarms

Volume fraction up to 5 %
methane in air indication

7 % measuring range or
15 % of indication

Indication at 90 % final value in


less than 30 s in either gas

t (10) in less than 60 s

t (50) in less than 20 s

t (90) in less than 60 s

t (50) in less than 20 s

5 % measuring range within


2 min, and no false alarm

Continuous duty portable:

5 % measuring range within


manual spec., and no false alarm

Fixed/transportable:

5 % measuring range or
10 % of indication

5 % measuring range or
10 % of indication, and no loss
of function, no fault signal, no
damage resulting in a hazard and
no false alarms

Volume fraction up to 100 %


gas indication

Group II apparatus limits


(whichever value is greater)

Group I apparatus limits


(whichever value is greater)

(increasing
concentration)

Drop test

5.4.14

5.4.16

Vibration

Test

5.4.13

Subclause

Table A.1 (continued)

60079-29-1 IEC:2007
39

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

Power supply
interruptions, voltage
transients and step
changes of voltage

Addition of sampling
probe

Dust

Poisons

5.4.21

5.4.22

5.4.23

5.4.24.1

6 % methane or
10 % of indication
(test: 10 min after low battery
condition)

Spot-reading apparatus:
3 % methane or
5 % of indication
(test: 200 operations)

0,2 % methane or
10 % of indication
(test: 10 min after low battery
condition)

Spot-reading apparatus:

0,1 % methane or
5 % of indication
(test: 200 operations)

3 % methane or
10 % of indication

t (90) increase less than 10 s

t (90) increase less than 10 s

0,2 % methane or
10 % of indication

5 % methane or
10 % of indication,

0,1 % methane or
5 % of indication,

3 % methane or
5 % of indication

No spurious alarms

No spurious alarms

0,1 % methane or
5 % of indication

3 % methane or
5 % of indication

0,1 % methane or
5 % of indication

6 % methane or
10 % of indication
(test: 10 operations after low
battery condition)

3 % methane or
5 % of indication
(test: 8 h or 10 h, respectively)

0,1 % methane or
5 % of indication
(test: 8 h or 10 h, respectively)

0,2 % methane or
10 % of indication
(test: 10 operations after low
battery condition)

Portable continuous duty:

Portable continuous duty:

Portable continuous duty:

Not applicable

Not applicable

Not applicable

Not applicable

5 % measuring range or
10 % of indication

No spurious alarms

3 % measuring range or
10 % of indication

6 % measuring range or
20 % of indication
(test: 10 operations after low
battery condition)

3 % measuring range or
10 % of indication
(test: 200 operations)

Spot-reading apparatus:

6 % measuring range or
20 % of indication
(test: 10 min after low battery
condition)

3 % measuring range or
10 % of indication
(test: 8 h or 10 h, respectively)

Portable continuous duty:

Volume fraction up to 100 %


gas indication

5 % measuring range or
10 % of indication

No spurious alarms

5 % measuring range or
10 % of indication

7 % measuring range or
15 % of indication
(test: 10 operations after low
battery condition)

5 % measuring range or
10 % of indication
(test: 200 operations)

Spot-reading apparatus:

7 % measuring range or
15 % of indication
(test: 10 min after low battery
condition)

5 % measuring range or
10 % of indication
(test: 8 h or 10 h, respectively)

Volume fraction up to 100 %


lower flammable limit indication

Volume fraction up to 100 %


methane in air indication

Group II apparatus limits


(whichever value is greater)

Group I apparatus limits


(whichever value is greater)

Volume fraction up to 5 %
methane in air indication

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Power supply variation

Battery capacity

Test

5.4.20

5.4.19

Subclause

Table A.1 (continued)

40
60079-29-1 IEC:2007

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Other gases

Electromagnetic
immunity

Field calibration kit

5.4.24.2

5.4.25

5.4.26

Test

0,1 % methane or
5 % of indication

Variation less than 0,1 %


methane and no spurious
alarms

10 % of the actual methane


volume fraction applied.

3 % methane or
5 % of indication

Variation less than 3 %


methane and no spurious
alarms

10 % of the actual methane


volume fraction applied.

Volume fraction up to 100 %


methane in air indication

5 % measuring range or
10 % of indication

Variation less than 5 %


measuring range and no spurious
alarms

Not applicable

Volume fraction up to 100 %


lower flammable limit indication

5 % measuring range or
10 % of indication

Variation less than 3 %


measuring range and no spurious
alarms

Not applicable

Volume fraction up to 100 %


gas indication

Group II apparatus limits


(whichever value is greater)

Group I apparatus limits


(whichever value is greater)

Volume fraction up to 5 %
methane in air indication

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Subclause

Table A.1 (continued)

60079-29-1 IEC:2007
41

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

42

60079-29-1 IEC:2007

Annex B
(informative)
Determination of time of response

B.1

Aspirated apparatus (see also Figure B.1)

The apparatus is attached to the equipment, for example as shown schematically in Figure
B.1.
If the on/off operation is independent of the aspirator control, the apparatus is switched on
and stabilized.
The two-way valve is adjusted to connect the apparatus to the clean air reservoir. Aspiration
is performed until the apparatus is stabilized. The apparatus "zero" control is adjusted as
necessary. Aspiration is stopped.
The two-way valve is adjusted to connect the apparatus to the test gas and aspiration is
commenced. The t (50) and t (90) times of response are taken as the time intervals between
the start of aspiration and the time when the apparatus reaches 50 % or 90 %, respectively, of
the final indication.
A correction should be made to the time of response to allow for the aspiration of the dead
volume between A and B in figure B.1.

B.2
B.2.1

Apparatus that samples by diffusion


Calibration mask method

Clean air is supplied to the apparatus, at the manufacturer's recommended linear flow rate but
not exceeding 1 m/s, via the mask (see 5.2.3 and 5.3.4) until the apparatus is stabilized. The
apparatus zero is adjusted as necessary. The test gas is then applied via a two-way valve.
The t (50) and t (90) times response are taken as the time intervals between the time of
application of the test gas and the time when the apparatus reaches 50 % or 90 %,
respectively, of the final indication.
If the size of the mask is such that the time required to purge it with gas (with the apparatus in
position) exceeds 25 % of the time of response of the apparatus, this test method is not
acceptable and an alternative method is to be used.
It is essential to correct the time response to allow for the dead volume between the two-way
tap and the entry port of the mask.
B.2.2

Applicator method (see also Figures B.2 to B.4)

The clean air supply is applied to the apparatus via an applicator, for example as shown in
Figure B.2. The applicator is held in position until the apparatus is stabilized. The apparatus
"zero" is adjusted as necessary.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

The apparatus is switched on and stabilized.

60079-29-1 IEC:2007

43

The test gas is applied to the apparatus via a second, identical applicator in a t (50) and t (90)
change over movement, for example as illustrated in Figure B.3. The t (50) and t (90) times of
response are taken as the time interval between the time of application of the test gas
applicator and the time when the apparatus reaches 50 % or 90 %, respectively, of the final
indication.
NOTE 1 The base of the applicator is in contact with the apparatus and completely surrounds the sensor inlet.
The area of the base is at least twice the area of the sensor inlet.
NOTE 2

The linear flow of clean air/test gas at the base of the applicators is 50 mm/s 5 mm/s.

NOTE 3 The gaps at the base of the applicator are sufficient to prevent an overpressure within the applicator of
more than 50 Pa (which corresponds to approximately a 5 mm head of water) with the applicator flush against the
apparatus or sensor as shown by Figure B.3.
NOTE 4 The distance between the shoulder of the applicator and the sensor inlet is typically 10 diameters of the
applicator, for example as shown in Figure B.4.
NOTE 5 It is envisioned that a range of applicators, based on the above parameters, will be required to test the
full range of apparatus or sensors.

B.2.3

Test chamber method

B.2.3.1

Test chamber

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

The construction of the chamber may encompass a wide variety in design from sophisticated
permanent installations to a simple specially constructed enclosure that, in the opinion of the
testing laboratory, is capable of introducing the gases or the sensors in a rapid and
reproducible manner.
An example of a test chamber is illustrated in Figure B.5.
B.2.3.2

Procedure

Test chambers may be used in either of two ways:


a) the chamber is first filled with the standard test gas and the sensor is then plunged inside
rapidly, or
b) the apparatus is put inside the chamber with the inlet of the sensor covered; the chamber
is then filled with the standard test gas, and the sensor inlet is rapidly uncovered.

B.3

Step change response (see also Figure B.6)

The apparatus used for this test is shown schematically in figure B.6 and operates as follows:
a) the lower vessel (1) is filled with water;
b) the toy balloon (2) is filled with a 100 % LFL gas/air mixture until it fills the lower end of
the tube (3);
c) the gas/air mixture is forced into the lower vessel until the balloon is forced up the tube as
far as it will go;
d) the balloon is fully inflated to seal the lower part of the tube;
e) the gas/air mixture is pumped into the lower vessel displacing the water into the upper
vessel (4);
f)

the sensor (5) is positioned in the tube about 5 cm above the upper end of the balloon and
the output of the instrument is connected to a recorder;

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

44

60079-29-1 IEC:2007

g) the balloon is broken by inserting a pin into the tube at point (6). This results in an
immediate release of the gas/air mixture from the balloon and from the 0,1 m 3 of volume in
the lower vessel which is at approximately 7 kPa pressure. This immediately purges the
tube and as the water returns to the lower vessel (which takes about 20 s) the tube is
provided with a continuous flow of fresh mixture travelling at a speed of approximately
20 m/s. The duration of the flow can be extended to 30 s (the maximum test time),
if necessary, by placing a restriction in the hose (7) between the two vessels. A recorder,
connected to the instrument output, will provide timing lines at 1 s intervals and this can
be used to determine the time required to reach the 50 % LFL and 90 % LFL readings. As
an alternative, the toy balloon in the 75 mm diameter tube may be replaced by a 75 mm
(type size) ball valve. This simplifies the procedure considerably and the same results
have been obtained by the rapid opening of the ball valve as by the bursting of the toy
balloon.

B.4

Flooding (see also Figure B.6)

This test is performed in the same manner as the step change response test in Clause B.3,
except that the test gas is used for filling the balloon and the lower vessel, instead of a gas/air
mixture.

Collapsible
gas containers

Test gas

Clean air

A
Two-way
valve
C
Joint

B
Apparatus inlet nozzle
or probe inlet
IEC 1295/07

NOTE 1 The volume of each gas reservoir is greater (by at least a factor of 10) than the volume of gas swept out
during a time of response determination.
The bore of all tubing and connections is greater than the bore of the apparatus inlet nozzle or probe

NOTE 3 The volume between the valve and the apparatus inlet (between B and C) is kept to a minimum
consistent with a good connection to the apparatus.

Figure B.1 Schematic example of equipment for use


with aspirated apparatus
(see also Clause B.1)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

NOTE 2
inlet.

60079-29-1 IEC:2007

45

Clean air or
test gas

Flow measuring
device
Flexible
tubing
Tubular
applicator

Sensor
inlet

Apparatus
or sensor
IEC 1296/07

Figure B.2 Schematic example of equipment during application


of clean air or test gas
(see also B.2.2)

Flow measuring
device

Flow measuring
device

Flexible
tubing

Test gas

Clean air

Identical tubular
applicators

Apparatus
or sensor
Sensor
inlet
Extract

IEC 1297/07

Figure B.3 Schematic example of equipment showing change-over from clean air
to test gas to begin the time of response measurement
(arrows indicate movement of applicators)
(see also B.2.2)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

46

60079-29-1 IEC:2007

Gas diffuser/baffle

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Shoulder of
applicator

Tubular
applicator
Flow of clean
air/test gas
10 d

Gap

Apparatus
or sensor

Sensor
inlet
IEC 1298/07

Figure B.4 Schematic example of applicator and sensor inlet


during application of test gas or clean air
(see also B.2.2)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

47

Infra-red

Alarm level

Safety valve
Gas valve
Gas concentration
in the test chamber
recorder

Excess air vent


Heating device

Damping tubes

Alarm
indicator

Mixing fan
1

Thermal
insulation
Cooler arrival

Detectors
signals
recorder

Sampling bulb
Damping system

1
2

Drying system

4
5

Control light
Cooler
IEC 1299/07

Figure B.5 Example of automated test chamber


(see also B.2.3.1)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

48

60079-29-1 IEC:2007

Clear plastic tube


(75 diameter 450 long)

Sensor

Water
Toy balloon

0 to 40 kPa psi
Pressure gauge

Opening
for pin
Gas
In

20 litre
container
Approx.
750

Gas tight vessel


(380 diameter 350 high)
Hose

Water
IEC 1300/07

Dimensions in millimetres

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Figure B.6 Apparatus for step change and flooding tests

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 IEC:2007

49

Bibliography
IEC 60050(351):1975, International Electrotechnical Vocabulary (IEV) Chapter 351:
Automatic control
IEC 60050(426):1990, International Electrotechnical Vocabulary (IEV) Chapter 426:
Electrical apparatus for explosive atmospheres
IEC 60068-2-6:1995, Environmental testing Part 2: Tests Test Fc: Vibration (sinusoidal).
IEC 60079-1: Explosive atmospheres Part 1: Equipment protection by flameproof enclosure
d
IEC 60079-2: Explosive atmospheres Part 2: Equipment protection by p ressurized
enclosures "p"
IEC 60079-5: Explosive atmospheres Part 5: Equipment protection by powder filling q
IEC 60079-6: Explosive atmospheres Part 6: Equipment protection by oil immersion "o"
IEC 60079-7: Explosive atmospheres Part 7: Equipment protection by increased safety "e"
IEC 60079-10: Electrical apparatus for explosive gas atmospheres Part 10: Classification of
hazardous areas
IEC 60079-11: Explosive atmospheres Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15: Electrical apparatus for explosive gas atmospheres Part 15: Construction,
test and marking of type of protection, "n" electrical apparatus
IEC 60079-18: Electrical apparatus for explosive gas atmospheres Part 18: Construction,
test and marking of type of protection encapsulation "m" electrical apparatus
IEC 60079-25: Electrical apparatus for explosive gas atmospheres Part 25: Intrinsically safe
systems
IEC 60079-26: Explosive atmospheres Part 26: Equipment with equipment protection level
(EPL) Ga
ISO 2738: Permeable sintered metal materials Determination of density, oil content, and
open porosity
ISO 4003: Permeable sintered metal materials Determination of bubble test pore size
ISO 4022: Permeable sintered metal materials Determination of fluid permeability
ISO 6142: Gas analysis Preparation of calibration gas mixtures Gravimetric methods
ISO 6145-1: Gas analysis Preparation of calibration gas mixtures Dynamic volumetric
methods Part 1: Review of methods of calibration
ISO 6145-2: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 2: Volumetric pumps
ISO 6145-4: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 4: Continuous injection method

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

50

60079-29-1 IEC:2007

ISO 6145-5: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 5: Capillary calibration devices
ISO 6145-6: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 6: Critical orifices
ISO 6145-7: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 7: Thermal mass-flow controllers
ISO 6145-9: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 9: Saturation method
ISO 6145-10: Gas analysis Preparation of calibration gas mixtures using dynamic volumetric
methods Part 10: Permeation method

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

___________

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

52

60079-29-1 CEI:2007

SOMMAIRE
AVANT-PROPOS .................................................................................................................. 55
INTRODUCTION................................................................................................................... 58
1

Domaine d'application .................................................................................................... 59

Rfrences normatives ................................................................................................... 60

Dfinitions ...................................................................................................................... 60

3.1 Proprits du gaz .................................................................................................. 60


3.2 Types dinstruments .............................................................................................. 62
3.3 Capteurs ............................................................................................................... 63
3.4 Dispositif damene de gaz linstrument.............................................................. 63
3.5 Signaux et alarmes................................................................................................ 64
3.6 Temps ................................................................................................................... 64
3.7 Divers ................................................................................................................... 65
Exigences gnrales ...................................................................................................... 66
4.1
4.2

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Introduction ........................................................................................................... 66
Construction .......................................................................................................... 66
4.2.1 Gnralits ................................................................................................ 66
4.2.2 Dispositifs dindication ............................................................................... 66
4.2.3 Alarme ou fonctions de sortie .................................................................... 67
4.2.4 Signaux de panne...................................................................................... 68
4.2.5 Rglages ................................................................................................... 68
4.2.6 Matriel aliment par accumulateur ........................................................... 68
4.2.7 Matriel de dtection de gaz autonome pour utilisation avec des
units de commande spares .................................................................. 68
4.2.8 Units de commande spares pour utilisation avec un matriel
autonome de dtection de gaz ................................................................... 69
4.2.9 Matriel command par logiciel ................................................................. 69
4.3 Etiquettes et marquage ......................................................................................... 71
4.4 Manuel d'Instruction .............................................................................................. 71
Mthodes dessai ........................................................................................................... 72
5.1
5.2

5.3

Introduction ........................................................................................................... 72
Exigences gnrales pour les essais ..................................................................... 72
5.2.1 Echantillons et ordre des essais ................................................................ 73
5.2.2 Prparation du matriel avant essai........................................................... 73
5.2.3 Masque pour talonnage et essais ............................................................ 74
Conditions normales dessais ................................................................................ 74
5.3.1 Gnralits ................................................................................................ 74
5.3.2 Gaz dessai ............................................................................................... 74
5.3.3 Gaz dessai normalis ............................................................................... 75
5.3.4 Dbit pour gaz dessai ............................................................................... 75
5.3.5 Tension ..................................................................................................... 75
5.3.6 Temprature .............................................................................................. 75
5.3.7 Pression .................................................................................................... 76
5.3.8 Humidit .................................................................................................... 76
5.3.9 Temps de stabilisation ............................................................................... 76
5.3.10 Orientation ................................................................................................ 76

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

5.4

53

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5.3.11 Options de communication ........................................................................ 76


5.3.12 Matriel de dtection de gaz constituant une partie de systme ................ 76
Mthodes dessai .................................................................................................. 76
5.4.1 Gnralits ................................................................................................ 76
5.4.2 Stockage hors alimentation........................................................................ 76
5.4.3 Etalonnage et rglage ............................................................................... 77
5.4.4 Stabilit (matriel rgime continu uniquement) ....................................... 77
5.4.5 Stabilit (matriel de lecture intermittente uniquement) ............................. 78
5.4.6 Point(s) de consigne dalarme ................................................................... 78
5.4.7 Temprature .............................................................................................. 79
5.4.8 Pression .................................................................................................... 79
5.4.9 Humidit .................................................................................................... 79
5.4.10 Vitesse de lair........................................................................................... 80
5.4.11 Dbit pour le matriel daspiration ............................................................. 80
5.4.12 Orientation ................................................................................................ 80
5.4.13 Vibration .................................................................................................... 81
5.4.14 Essai de chute pour matriel portable et transportable .............................. 81
5.4.15 Temps d'chauffement, ............................................................................. 82
5.4.16 Temps de rponse (non applicable au matriel lecture
intermittente) ............................................................................................. 82
5.4.17 Temps minimum de fonctionnement (matriel lecture intermittente) ........ 82
5.4.18 Concentration leve de gaz au-dessus de ltendue de mesure ............... 82
5.4.19 Capacit de laccumulateur........................................................................ 83
5.4.20 Drives de lalimentation de puissance ...................................................... 84
5.4.21 Interruptions de lalimentation de puissance, transitoires et drives
de tension ................................................................................................. 84
5.4.22 Ajout dune sonde dchantillonnage.......................................................... 84
5.4.23 Poussire (pour matriel o lair est mis en chantillon uniquement
par diffusion naturelle) ............................................................................... 85
5.4.24 Poisons et autres gaz ................................................................................ 85
5.4.25 Immunit lectromagntique ...................................................................... 86
5.4.26 Kit dtalonnage de terrain......................................................................... 86
5.4.27 Vrification du logiciel ............................................................................... 86

Annexe A (normative) Exigences daptitude la fonction ..................................................... 87


Annexe B (informative) Dtermination du temps de rponse ................................................ 92
Bibliographie......................................................................................................................... 99
Figure 1 Temps dchauffement en air propre (typique) ..................................................... 65
Figure 2 Temps dchauffement en gaz dessai normalis (typique) ................................... 65
Figure B.1 Exemple schmatique dquipement pour utilisation avec du matriel
aspiration.............................................................................................................................. 94
Figure B.2 Exemple schmatique dquipement pendant lapplication dair propre ou
de gaz dessai....................................................................................................................... 95
Figure B.3 Exemple schmatique dquipement montrant un changement de lair
propre au gaz dessai pour dbuter les mesures du temps de rponse (les flches
indiquent le mouvement des applicateurs) ............................................................................ 95

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

54

60079-29-1 CEI:2007

Figure B.4 Exemple schmatique dentre dapplicateur ou de capteur pendant


lapplication de gaz dessai ou dair propre ........................................................................... 96
Figure B.5 Exemple de chambre dessai automatique ........................................................ 97
Figure B.6 Matriel pour essais de rponse aux variations et essai darrosage .................. 98
Tableau A.1 Exigences daptitude la fonction .................................................................. 87

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

55

COMMISSION LECTROTECHNIQUE INTERNATIONALE


____________
ATMOSPHRES EXPLOSIVES
Partie 29-1: Dtecteurs de gaz
Exigences daptitude la fonction des dtecteurs de gaz inflammables
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
compose de l'ensemble des comits lectrotechniques nationaux (Comits nationaux de la CEI). La CEI a
pour objet de favoriser la coopration internationale pour toutes les questions de normalisation dans les
domaines de l'lectricit et de l'lectronique. A cet effet, la CEI entre autres activits publie des Normes
internationales, des Spcifications techniques, des Rapports techniques, des Spcifications accessibles au
public (PAS) et des Guides (ci-aprs dnomms "Publication(s) de la CEI"). Leur laboration est confie des
comits d'tudes, aux travaux desquels tout Comit national intress par le sujet trait peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
galement aux travaux. La CEI collabore troitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixes par accord entre les deux organisations.
2) Les dcisions ou accords officiels de la CEI concernant les questions techniques reprsentent, dans la mesure
du possible, un accord international sur les sujets tudis, tant donn que les Comits nationaux de la CEI
intresss sont reprsents dans chaque comit dtudes.
3) Les Publications de la CEI se prsentent sous la forme de recommandations internationales et sont agres
comme telles par les Comits nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas tre tenue responsable
de l'ventuelle mauvaise utilisation ou interprtation qui en est faite par un quelconque utilisateur final.

5) La CEI na prvu aucune procdure de marquage valant indication dapprobation et n'engage pas sa
responsabilit pour les quipements dclars conformes une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernire dition de cette publication.
7) Aucune responsabilit ne doit tre impute la CEI, ses administrateurs, employs, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comits d'tudes et des Comits
nationaux de la CEI, pour tout prjudice caus en cas de dommages corporels et matriels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les cots (y compris les frais
de justice) et les dpenses dcoulant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crdit qui lui est accord.
8) L'attention est attire sur les rfrences normatives cites dans cette publication. L'utilisation de publications
rfrences est obligatoire pour une application correcte de la prsente publication.
9) Lattention est attire sur le fait que certains des lments de la prsente Publication de la CEI peuvent faire
lobjet de droits de proprit intellectuelle ou de droits analogues. La CEI ne saurait tre tenue pour
responsable de ne pas avoir identifi de tels droits de proprit et de ne pas avoir signal leur existence.

La Norme internationale CEI 60079-29-1 a t tablie par le comit d'tudes 31 de la CEI:


Matriel pour atmosphres explosives.
Cette premire dition de la CEI 60079-29-1 annule et remplace la premire dition de la
srie CEI 61779-1 la CEI 61779-5:1998 et constitue une rvision technique.
Les modifications principales par rapport ldition prcdente sont les suivantes:

Le Paragraphe 4.2.3 (Alarme ou fonction de sortie) a t modifi pour garantir que les
dispositifs dalarme ne peuvent pas tre rgls hors de leur tendue de mesure et pour
inclure des exigences pour la dsactivation des dispositifs dalarme.

Le Paragraphe 4.2.7 (Matriels autonomes de dtection de gaz pour une utilisation avec
une unit de commande spare) a t ajout pour permettre lvaluation spare du
matriel de dtection fournissant un signal de sortie reconnu par lindustrie.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

4) Dans le but d'encourager l'uniformit internationale, les Comits nationaux de la CEI s'engagent, dans toute la
mesure possible, appliquer de faon transparente les Publications de la CEI dans leurs publications
nationales et rgionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou rgionales correspondantes doivent tre indiques en termes clairs dans ces dernires.

60079-29-1 CEI:2007

Le Paragraphe 4.2.8 (Units de commande spares pour une utilisation avec des
matriels autonomes de dtection de gaz) a t ajout pour permettre lvaluation
spare du matriel de dtection fournissant un signal de sortie reconnu par lindustrie.

Le Paragraphe 4.2.9 (Matriels commands par logiciel) a t ajout au document pour


amliorer lvaluation du logiciel. Le texte ajout est fond sur les principes de
recommandation et les exigences de la EN 50271.

Le Paragraphe 4.5 (Capteurs diffusion) a t retir du document du fait de lacceptation


de protection redondante pour le matriel utilis en Zone 0, tels que les matriels classs
Ex d ia.

Le Paragraphe 5.2.1.1 a t modifi pour exiger que la longueur donde centrale des
filtres optiques de deux matriels soit prise comme limites minimale et maximales de cette
norme.

Le Paragraphe 5.2.1.2 a t modifi pour permettre aux laboratoires dessai de raliser


les essais dans l'ordre qui leur convient.

Le Paragraphe 5.3.11 (Options de communication) a t ajoute pour assurer que le flux


maximal de transmissions est appliqu pendant les essais.

Le Paragraphe 5.3.12 (Matriels de dtection de gaz constituant une partie dun systme)
a t ajout pour assurer que le flux maximal de transmissions est appliqu pendant les
essais.

Le Paragraphe 5.4.6 (Point(s) de rglage des alarmes) a t modifi pour traiter des
alarmes qui sont actives des concentrations dcroissantes.

Le Paragraphe 5.4.10 (Vitesse de lair) a t modifi pour inclure les essais 3 m/s et 6
m/s.

Le Paragraphe 5.4.16 (Temps de rponse) a t modifi pour exclure les exigences de


lessai de temps de recouvrement pour les matriels de Groupe II avec un titre volumique
jusqu' lindication 100 % LII.

Le Paragraphe 5.4.18 (Fonctionnement en concentrations de gaz leves au-dessus de


ltendue de mesures) a t modifi pour dfinir la squence des essais.

LAnnexe A (Exigences daptitude la fonction) a subi des modifications majeures par


llimination de tableau gaz/vapeur et le remplacement de lannexe par les exigences
d'aptitude la fonction des Parties 2 5 de lancienne dition. De plus, les exigences
daptitude des Parties 2 5 ont t revues pour en assurer la cohrence. Le but de cette
modification est de condenser les Parties 1 5 dans une norme unique.

La prsente partie de la CEI 60079-29 doit tre utilise conjointement avec les normes
suivantes :

CEI 60079-0, Matriel lectrique pour atmosphres explosives gazeuses Partie 0:


Rgles gnrales

CEI 60079-29-2, Atmosphres explosives Partie 29-2 : Dtecteurs de gaz Slection,


installation, utilisation et maintenance des dtecteurs de gaz inflammables et doxygne.

Le texte de la prsente norme est issu des documents suivants:


FDIS

Rapport de vote

31/695/FDIS

31/711/RVD

Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant
abouti l'approbation de la prsente Norme.
Cette publication a t rdige selon les Directives ISO/CEI, Partie 2.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

56

60079-29-1 CEI:2007

57

Une liste de toutes les parties de la CEI 60079, sous le titre gnral : Atmosphres
explosives, est disponible sur le site web de la CEI.
Le comit a dcid que le contenu de cette publication ne sera pas modifi avant la date de
maintenance indique sur le site web de la CEI sous "http://webstore.iec.ch" dans les
donnes relatives la publication recherche. A cette date, la publication sera
reconduite;
supprime;
remplace par une dition rvise, ou
amende.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

58

60079-29-1 CEI:2007

INTRODUCTION
Des recommandations pour la slection, linstallation, lutilisation et la maintenance des
matriels de dtection de gaz sont tablies dans la CEI 60079-29-2: Atmosphres
explosives Partie 29-2: Dtecteurs de gaz Slection, installation, utilisation et
maintenance des dtecteurs de gaz inflammables et doxygne.
.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

59

ATMOSPHRES EXPLOSIVES
Partie 29-1: Dtecteurs de gaz
Exigences daptitude la fonction des dtecteurs de gaz inflammables

Domaine d'application

Cette norme sapplique pour toute revendication quun constructeur de matriel pourrait
mettre pour une caractristique spcifique de construction ou daptitude la fonction
suprieure aux exigences minimales. Il convient que de telles revendications soient vrifies
et que les procdures dessai soient tendues ou compltes lorsque cela est ncessaire,
pour vrifier laptitude la fonction dclare par le fabricant. Lors de la vrification dune
aptitude la fonction suprieure un critre, le respect des autres critres daptitude la
fonction par rapport aux exigences minimales de la norme, nest pas exig. Cependant, il
convient que ces aptitudes la fonction rduites dclares (telles que confirmes dans le
manuel dinstruction du constructeur) soient aussi vrifies (par exemple une gamme de
tempratures de 0 C 60 C; de 0 C 40 C une prcision de 10 % et de 40 C 60 C
une prcision de 15 % (prcision revendique par le constructeur). Il convient que les
essais complmentaires fassent lobjet dun accord entre le constructeur et le laboratoire
dessai et identifis et dcrits dans le rapport dessais.
Cette norme sapplique aux matriels de dtection de gaz combustibles destins donner
une indication, une alarme ou une autre fonction de sortie, le but tant dalerter sur un risque
dexplosion et, dans certains cas de dclencher des actions protectrices manuelles ou
automatiques.
Cette norme sapplique aux matriels, comprenant lintgralit des systmes
dchantillonnage des matriels aspiration, destins tre utiliss dans des applications de
scurit industrielles, commerciales et non rsidentielles.
Cette norme ne sapplique pas aux systmes par chantillonnage externes, ou aux matriels
de laboratoire ou de type scientifique, ou aux matriels utiliss uniquement pour la commande
de processus. Elle ne sapplique pas non plus la surveillance des emplacements par des
matriels de dtection chemin ouvert (Open Path). Pour les matriels dtectant la prsence
de plusieurs gaz, cette norme sapplique uniquement pour la dtection des gaz ou vapeurs
inflammables.
Cette norme complte et modifie les exigences gnrales de la CEI 60079-0. Lorsquune
exigence de cette norme entre en conflit avec une exigence de la CEI 60079-0, lexigence de
la CEI 60079-29-1 prvaudra.
NOTE 1 La CEI 60079-29-1 est destine permettre la fourniture de matriels donnant un niveau de scurit et
une aptitude la fonction approprie aux applications gnrales. Cependant, pour les applications spcifiques, un
acheteur ventuel (ou une autorit approprie) peut exiger en plus que le matriel soit soumis des essais
particuliers ou une approbation. Par exemple, un matriel de groupe I (cest--dire un matriel pour une
utilisation dans des mines grisouteuses) peut ne pas tre autoris pour une utilisation sans un essai
complmentaire, avant lapprobation par lautorit comptente dans les mines sous sa juridiction. De tels

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

La prsente partie de la CEI 60079-29 spcifie les exigences gnrales pour la construction,
les essais et laptitude la fonction, et dcrit les mthodes dessai qui sappliquent aux
matriels portables, transportables et fixes pour la dtection et la mesure des concentrations
de gaz ou de vapeurs inflammables dans lair. Les matriels, ou parties de ceux-ci, sont
destins tre utiliss dans des atmosphres potentiellement explosives (voir 3.1.8) et dans
les mines grisouteuses.

60

60079-29-1 CEI:2007

essais/approbations particuliers seront considrs comme des dispositions complmentaires et spares de celles
des normes en rfrence ci-dessus et elles n'invalident pas la conformit ces normes.
NOTE 2 Les matriels talonns pour des gaz et vapeurs spcifiques ne peuvent en aucun cas tre considrs
pouvoir fournir des indications correctes pour dautres gaz ou vapeurs.
NOTE 3 Pour les besoins de cette norme, les termes limite infrieure dinflammabilit (LII) et limite
infrieure dexplosivit (LIE) sont considrs synonymes, et de la mme faon les termes limite
suprieure dinflammabilit (LSI) et limite suprieure dexplosivit (LSE) sont considrs synonymes. Pour en
faciliter la rfrence, les deux abrviations LII et LSI seront utilises ci-aprs pour indiquer ces deux dfinitions.
Les autorits particulires peuvent avoir des exigences prpondrantes qui dicteront lutilisation de lun de ces
termes plutt que de lautre.
NOTE 4 Pour les besoins de la prsente norme, lexpression "indiquant jusqu' un titre volumique de X % inclut
les matriels ayant une limite suprieure de ltendue de mesure gale ou infrieure X %.

Rfrences normatives

Les documents de rfrences suivants sont indispensables pour l'application du prsent


document. Pour des rfrences dates, seule l'dition cite s'applique. Pour les rfrences
non dates, cest la dernire dition du document rfrenc (y compris les ventuels
amendements) qui sapplique.
CEI 60079-0: Matriels lectriques pour atmosphres explosives gazeuses Partie 0:
Exigences gnrales
CEI 60079-20: Matriels lectriques pour atmosphres explosives gazeuses Partie 20:
Donnes pour gaz et vapeurs inflammables, en relation avec l'utilisation des matriels
lectriques
CEI 60079-29-2, Atmosphres explosives Partie 29-2: Dtecteurs de gaz Slection,
installation, utilisation et maintenance des dtecteurs de gaz inflammables et doxygne
CEI 61000-4-1: Compatibilit lectromagntique (CEM) Partie 4-1: Techniques d'essai et
de mesure Vue densemblede la srie CEI 61000-4. Publication fondamentale en CEM
CEI 61000-4-3: Compatibilit lectromagntique (CEM) Partie 4-3: Techniques d'essai et
de mesure Essai d'immunit aux champs lectromagntiques rayonns aux frquences
radiolectriques. Publication fondamentale en CEM
CEI 61000-4-4: Compatibilit lectromagntique (CEM) Partie 4-4: Techniques d'essai et
de mesure Essais d'immunit aux transitoires lectriques rapides en salves. Publication
fondamentale en CEM

Termes et dfinitions

Pour les besoins du prsent document, les termes et dfinitions donns dans la CEI 60079-0
et ceux qui suivent sappliquent.
NOTE D'autres dfinitions applicables aux atmosphres explosives sont donnes dans le chapitre 426 du
Vocabulaire Electrotechnique International (VEI) CEI 60050 (426).

3.1

Proprits du gaz

3.1.1
air ambiant
atmosphre normale entourant le matriel

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

61

3.1.2
air propre
air sans gaz inflammable ou substance interfrente ou polluante
3.1.3
atmosphre explosive gazeuse
mlange avec l'air, dans des conditions atmosphriques normales, de substances
inflammables sous forme de gaz, vapeurs ou brouillards, dans lequel, aprs inflammation, la
combustion se propage l'ensemble du mlange non brl
NOTE 1 Cette dfinition exclut spcifiquement les poussires et fibres en suspension dans lair. Les brouillards
ne sont pas couverts par la prsente norme.
NOTE 2 Mme si un mlange ayant une concentration au-dessus de la limite suprieure dinflammation (voir
3.1.9) nest pas une atmosphre explosive, dans certains cas pour des besoins de classification de zones, il est
recommand de la considrer comme atmosphre explosive gazeuse.
NOTE 3 Des conditions atmosphriques normales incluent des variations au-dessus et en dessous des niveaux
de rfrence de 101,3 kPa et 20 C condition que les variations aient un effet ngligeable sur les proprits
dexplosion du matriel inflammable.

3.1.4
grisou
gaz inflammable, compos principalement de mthane, se trouvant ltat naturel dans les
mines
3.1.5
gaz inflammable
gaz ou vapeur qui, mlang de lair dans certaines proportions, formera une atmosphre
explosive
NOTE

Pour les besoins de la prsente norme, le terme gaz inflammable inclura les vapeurs inflammables.

3.1.6
limite infrieure dinflammabilit
LII
titre volumique de gaz ou de vapeur inflammable dans lair au-dessous, de laquelle ne se
forme pas une atmosphre explosive gazeuse, et exprime en pourcentage (voir CEI 6007920)
NOTE

Connu aussi comme limite infrieure dexplosivit (LIE).

3.1.7
poisons (de capteurs)
substances, qui conduisent une perte temporaire ou permanente de la sensibilit des
capteurs
3.1.8
atmosphre potentiellement explosive
atmosphre qui peut devenir explosive (le danger est potentiel)
NOTE Ceci peut inclure une atmosphre avec une concentration de gaz suprieure LSI un instant donn et
quune dilution dans lair rendrait explosive.

3.1.9
limite suprieure dinflammabilit
LSI
titre volumique de gaz ou de vapeur inflammable dans lair au-dessus, de laquelle ne se
forme pas une atmosphre explosive gazeuse, et exprime en pourcentage (voir CEI 6007920)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

62
NOTE

60079-29-1 CEI:2007

Connu aussi comme limite infrieure dexplosivit (LSE).

3.1.10
titre volumique (v/v)
rapport du volume dun compos spcifi sur la somme des volumes des tous les composs
dun mlange gazeux avant le mlange, tous les volumes tant exprims la pression et la
temprature du mlange gazeux

3.1.11
gaz zro
gaz, recommand par le constructeur, sans gaz inflammable, ni substances polluantes ou
interfrentes, destin ltalonnage/ajustement du zro du matriel
3.2

Types dinstruments

3.2.1
matriel alarme uniquement
matriel ayant une alarme mais nayant pas un dispositif de mesure ou dautre dispositif
dindication
3.2.2
matriel aspiration
matriel qui prlve le gaz en laspirant vers les capteurs de gaz par exemple,
manuellement ou laide dune pompe lectrique ou mcanique
3.2.3
matriel rgime continu
matriel en fonctionnement sur de longues priodes, mais dont les capteurs fonctionnent en
continu ou par intermittence
3.2.4
matriel de diffusion
matriel dans lequel le transfert de gaz de latmosphre vers le capteur de gaz seffectue en
un mouvement de molcule alatoire, cest--dire dans des conditions o il ny a pas de flux
aspiratoire
3.2.5
matriel fixe
matriel qui est destin tre dans sa totalit, install en permanence
3.2.6
matriel du groupe I
matriel pour les mines grisouteuses
3.2.7
matriel du groupe II
matriel destin des lieux en atmosphre explosible, autres que les mines grisouteuses
3.2.8
matriel portable
matriel lecture intermittente ou continue conu pour tre transport dun endroit un autre
et utilis pendant le dplacement. Un matriel portable fonctionne sur accumulateur et
comprend, entre autres

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

NOTE Le titre volumique et la concentration volumique ont la mme valeur si dans les mmes conditions dtat, la
somme des volumes des composants avant mlange et le volume du mlange sont gaux. Cependant, du fait
quun mlange de deux ou plusieurs gaz dans les mmes conditions dtat est gnralement accompagn dune
lgre contraction, ou moins frquemment dune lgre expansion, ce nest gnralement pas le cas.

60079-29-1 CEI:2007

63

a) un matriel portable, typiquement de moins de 1 kg, qui est utilis en tant tenu dans une
seule main,
b) des moniteurs personnels, similaires en taille et poids aux matriels portables, qui
fonctionnent en permanence (mais pas ncessairement en continu) tant quils sont
attachs leur utilisateur,
c) du matriel de plus grandes dimensions, pouvant tre actionn par lutilisateur tout en le
portant la main, en bandoulire ou avec des harnais, avec ou sans sonde orientable
manuellement.
3.2.9
matriel lecture intermittente
matriel destin une utilisation sur des dures brves, intermittentes ou irrgulires selon la
ncessit (typiquement pendant 5 min ou moins)
3.2.10
matriel transportable
matriel ntant pas destin tre portable mais qui peut tre transport dun endroit un
autre
3.2.11
matriel de dtection de gaz autonome
matriel fixe de dtection de gaz qui fournit un signal lectronique normalis ou une
indication de sortie aux standards de lindustrie (tels que 4-20 mA ou 3-15 psi) destin une
utilisation avec des units de commandes autonomes, ou des systmes dacquisition de
donnes des centrales de surveillance et autres systmes analogues qui gnralement
traitent des informations provenant de diffrents emplacements et sources, incluant, entre
autres, les matriels de dtection de gaz
3.2.12
unit de commande autonome
unit fixe de commande de dtection de gaz destine fournir une indication de mesure, des
fonctions dalarme, des contacts de sortie et/ou des sorties de signal dalarme quand elle est
utilise avec un matriel de dtection de gaz
3.3

Capteurs

3.3.1
capteur distance
capteur non intgr au corps principal du matriel
3.3.2
capteur
ensemble dans lequel est log l'lment sensible et qui peut contenir des composants du
circuit associs
3.4

Dispositif damene de gaz linstrument

3.4.1
ligne dchantillonnage
dispositif par lequel le gaz chantillonn est conduit jusqu'au capteur, accessoires inclus (par
exemple, filtre, pige eau)
3.4.2
sonde de prlvement
ligne dchantillonnage spare qui est fixe au matriel comme prvu et qui est fournie ou
non avec le matriel. Elle est souvent courte (de lordre de 1 m) et rigide (mme si elle peut
tre tlescopique), mais peut tre connecte au matriel par un tube flexible

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

64
3.5

60079-29-1 CEI:2007

Signaux et alarmes

3.5.1
point de consigne de lalarme
rglage ajustable ou fixe du matriel destin prrgler le niveau de concentration auquel le
matriel dclenchera automatiquement une indication, une alarme ou autre fonction de sortie
3.5.2
signal de dfaut
audible, visible ou dun autre type diffrent du signal dalarme, permettant, directement ou
indirectement, un avertissement ou une indication de dysfonctionnement du matriel
3.5.3
alarme verrouillage
alarme, qui une fois active, requiert une action dlibre pour tre dsactive
3.5.4
tat spcial
tout tat du matriel autre que ceux pour lesquels la surveillance de la concentration de gaz
est active, par exemple le prchauffage, les modes dtalonnage ou les dfauts
3.6

Temps

3.6.1
drive
drive de lindication du matriel dans le temps en prsence de concentration fixe de gaz (air
propre inclus), dans des conditions ambiantes constantes
3.6.2
indication finale
indication donne par le matriel aprs stabilisation
3.6.3
temps minimal de fonctionnement (matriel lecture intermittente)
intervalle de temps entre le dclenchement dune procdure de mesure et le temps ou
lindication du matriel atteint un pourcentage tabli de lindication finale

3.6.5
temps de rponse t(x) (non applicable au matriel de lecture intermittente)
intervalle de temps, aprs le temps dchauffement du matriel, entre linstant o le
changement instantan entre air propre et gaz dessai normalis, ou vice versa, se produit
lentre du matriel et linstant o la rponse atteint un pourcentage fix (x) du signal stabilis
pour le gaz dessai normalis
3.6.6
temps dchauffement (non applicable au matriel lecture intermittente)
intervalle de temps, le matriel tant dans une atmosphre donne, entre le temps o le
matriel est mis en fonctionnement et le temps o lindication atteint et se maintient dans les
tolrances fixes (voir Figures 1 et 2)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

3.6.4
stabilisation
tat lorsque trois lectures successives dun matriel, prises 2 min dintervalles, nindiquent
pas de changement suprieur 1 % de ltendue de mesure

60079-29-1 CEI:2007
3.7

65

Divers

3.7.1
tension dalimentation nominale
tension donne par les constructeurs comme tension de fonctionnement recommande pour
les matriels de dtection de gaz
3.7.2
outil spcial
outil ncessaire pour accder aux commandes ou les rgler. La conception de loutil est
destine dcourager les interventions non autorises sur le matriel

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

3.7.3
type de protection
mesures appliques dans la construction de matriel lectrique pour viter linflammation de
latmosphre explosive environnante par de tels matriels (voir 4.1.2)

Indication

A larrt
lair propre

En marche
lair propre

Tolrance

Zro du
matriel

} spcifie sur

indication zro

Temps
0

Temps dchauffement
(voir 3.6.6)

IEC 1293/07

Figure 1 Temps dchauffement en air propre (typique)

Indication
A larrt en
gaz dessai
standard

En marche en
gaz dessai
standard
Tolrence

Rapport
volumique du
gaz dessai
standard

Zero en air
0
propre

de
} spcifie
lindication

Temps
0

Temps dchauffement
(voir 3.6.6)
IEC 1294/07

Figure 2 Temps dchauffement en gaz dessai normalis (typique)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

66

60079-29-1 CEI:2007

Exigences gnrales

4.1

Introduction

4.1.1 Le matriel doit tre conforme aux exigences de la prsente norme et aux critres de
l'Annexe A.
Lorsquun constructeur de matriel revendique un dispositif spcial de construction ou une
aptitude la fonction suprieure qui dpasse ces exigences minimales, de telles
revendications doivent tre vrifies et les procdures dessai largies ou compltes, si
ncessaire, pour vrifier laptitude la fonction dclare.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

4.1.2 Les assemblages et les composants lectriques doivent tre conformes avec les
exigences dessai et de construction de 4.2 et de lArticle 5, si applicable. De plus, les parties
des matriels de dtection des gaz combustibles destines une utilisation en emplacement
dangereux doivent tre constitues de matriaux conformes aux rgles de construction et de
protection contre lexplosion telles que spcifies dans les autres parties appropries de la
srie CEI 60079.
Pour certains types de matriel, les limites de temprature de fonctionnement et de stockage
de la prsente norme peuvent dpasser les limites de temprature exiges pour ces autres
normes de la srie 60079. Cest pourquoi, la certification des modes de protection utiliss
pour le matriel doit couvrir des gammes tendues de temprature. Par mesure
conservatoire, quand la certification daptitude la fonction est exige au del des limites
normales de temprature relatives aux modes de protection utilises, la temprature d'essai
dpassant les tendues exiges dans la prsente norme doit tre modifie en consquence.
4.1.3 Pour le matriel de groupe I, tous les circuits lectriques destins tre installs dans
le mme emplacement que le capteur, y compris ceux inclus dans le capteur, doivent tre de
scurit intrinsque ( ia ), les lments sensibles doivent tre de scurit intrinsque, et
leur enveloppe doit tre conforme aux exigences de scurit spcifies en 4.1.2.
4.2

Construction

4.2.1

Gnralits

Les matriels de dtection de gaz ou parties de ceux-ci (par exemple, capteurs distance)
spcifiquement destins lutilisation en prsence de gaz ou de vapeurs corrosives, ou qui
peuvent produire des sous-produits corrosifs comme rsultat du processus de dtection (par
exemple, oxydation catalytique ou autre processus chimique) doivent tre construits dans des
matriaux connus pour tre rsistants la corrosion de telles substances.
Tous les matriaux et composants doivent tre construits pour faciliter des vrifications
rgulires de la prcision.
Tous les matriels et composants utiliss dans la construction du matriel doivent tre utiliss
dans les limites et les caractristiques assignes par le constructeur, moins quil en soit
spcifi autrement dans les normes de scurit appropries.
NOTE Pour le matriel bas sur le principe de labsorption dans lequel le gaz pntre par diffusion, la chambre
optique peut avoir une longueur de plus de 30 cm. Cependant, pour des applications spcifiques une longueur
optique de chambre fixe plus longue peut tre employe pour des applications de dtection de gaz en mesure
ponctuelle.

4.2.2
4.2.2.1

Dispositifs dindication
Gnralits

Une indication doit signaler que le matriel est sous tension.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007
NOTE

67

Pour le matriel fixe, lindication peut tre donne par l'unit de commande.

4.2.2.2

Rsolution

Pour le matriel alarme uniquement ou le matriel o la rsolution du dispositif de lecture


est inadquate pour dmontrer la conformit avec cette norme, le constructeur doit identifier
des points de mesure adapts pour les dispositifs denregistrement ou de mesure pour
prouver la conformit du matriel cette norme. Lindication sur le dispositif de lecture ne
doit pas contredire les rsultats obtenus par ces dispositifs complmentaires dindication ou
denregistrement.
4.2.2.3

Etendue de mesure

Les mesures en de ou au-del de la plage dfinie doivent tre clairement indiques.


4.2.2.4

Etendues slectionnables

Si le matriel a plus dune tendue de mesures, ltendue choisie doit tre clairement
identifie.
4.2.2.5

Voyant dindication

Si un seul voyant dindication est fourni pour les signaux dalarme, de panne ou autre
indication, il doit tre de couleur rouge. Si des voyants dindication spars sont utiliss ou si
un voyant multicouleur est utilis, les couleurs doivent tre utilises dans lordre de priorit
suivant ((a) tant la plus haute priorit):
a) les alarmes signalant la prsence dune concentration de gaz au-del dun point de
consigne dalarme doivent tre de couleur ROUGE,
b) les indicateurs de panne dquipement doivent tre de couleur JAUNE,
c) les indicateurs dalimentation doivent tre de couleur VERTE.
4.2.2.6

Marquage du voyant dindication

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

En plus des exigences de couleur, les indicateurs lumineux doivent tre correctement
tiquets pour indiquer leur fonction.
4.2.3

Alarme ou fonctions de sortie

4.2.3.1

Gnralits

Les dispositifs dalarme ne doivent pas tre rglables des valeurs en dehors de ltendue de
mesure.
4.2.3.2

Matriel rgime continu

Si des dispositifs dalarme, des contacts de sortie ou des signaux de sortie dalarme sont
fournis comme partie intgrante de matriel portable ou fixe rgime continu et sils sont
destins fonctionner lorsquune concentration de gaz potentiellement dangereuse est
dtecte, ils doivent tre du type verrouillage ncessitant une action manuelle dlibre
pour arrter lalarme. Si deux ou plusieurs niveaux de rglage dalarme sont fournies, le plus
bas peut tre non verrouill selon la prfrence de lutilisateur. Les alarmes doivent rester en
fonctionnement tant que la condition dalarme est prsente. Une alarme sonore
complmentaire peut tre rendue silencieuse.
NOTE

Le dispositif de verrouillage peut tre ralis par le logiciel.

S'il est possible de dsactiver les dispositifs d'alarme, les contacts de sortie ou les sorties du
signal d'alarme (par exemple pour talonnage), cette dsactivation doit tre indique par un

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

68

60079-29-1 CEI:2007

signal. Pour le matriel fixe, ceci doit inclure un contact ou un autre signal de sortie
transmissible, sauf si les alarmes sont automatiquement ractives dans les 15 min.
4.2.3.3

Matriel de groupe I portable indiquant jusqu 5 % v/v

Les dispositifs dalarme ne doivent pas tre rglables au-dessus de 3 % v/v. Une alarme
complmentaire de dpassement de ltendue de mesure indiquant que la pleine chelle a t
dpasse peut tre fournie.
4.2.3.4

Matriel portable du groupe II indiquant jusqu 100 % de LII

Les dispositifs dalarme ne doivent pas pouvoir tre rgls au-dessus de 60 % LII. Une
alarme complmentaire de dpassement de ltendue de mesure indiquant que la pleine
chelle a t dpasse peut tre fournie.
NOTE Pour les autres matriels du groupe II, il est recommand que les dispositifs dalarme soient rgls pour
fonctionner un titre volumique de gaz qui ne soit pas suprieur 60 % LII.

4.2.4

Signaux de panne

Le matriel fixe et transportable doit fournir un signal de panne dans le cas de dfaillance de
lalimentation du matriel.
Un court-circuit ou circuit ouvert dans les connexions dun capteur doit tre indiqu par un
signal de panne.
Un matriel aspiration automatique doit tre fourni:
a) dans le cas de matriel transportable ou fixe: avec un dispositif dindication du dbit
intgr qui produit un signal de panne dans le cas dune dfaillance du dbit,
b) dans le cas de matriel portable: avec un dispositif de vrification du dbit de lair.
4.2.5

Rglages

Tous les dispositifs de rglage doivent tre conus de faon dcourager les interventions
accidentelles ou non autorises sur le matriel. Par exemple: des procdures spciales, dans
le cas dun instrument clavier, ou un dispositif mcanique tel quun couvercle ncessitant
lutilisation dun outil pour son ouverture.
Le matriel fixe protg contre lexplosion laide denveloppes doit tre conu de faon ce
que, si des dispositifs de rglage sont ncessaires pour des talonnages de routine ou toutes
actions similaires, ces dispositifs soient accessibles de lextrieur. Les dispositifs de rglage
ne doivent pas dgrader la protection du matriel contre lexplosion.
Les rglages du zro et de lamplification du signal doivent tre conus pour que le rglage
de lun naffecte pas celui de lautre.
4.2.6

Matriel aliment par accumulateur

Le matriel aliment par un accumulateur intgr doit tre fourni avec une indication de
conditions daccumulateurs faible, et la nature et lobjet de cette indication doit tre explique
dans le manuel (voir 4.4 j)).
4.2.7

Matriel de dtection de gaz autonome pour utilisation avec des units de


commande spares

Une spcification fournie avec le matriel, doit dcrire la relation entre la concentration de
gaz (dtecte par le matriel) et le signal de sortie ou lindication correspondante (fonction
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

69

de transfert). Cette spcification doit tre suffisamment dtaille pour que la prcision de
cette fonction de transfert puisse tre vrifie. Au minimum, le constructeur doit fournir les
donnes montrant la relation entre le signal de sortie et la concentration de gaz 0, 10 %,
25 %, 50 %, 75 % et 100 % de lindication pleine chelle de la sortie. Les signaux de sortie
pleine chelle et dtat (par exemple, dfaut, inhibition) doivent aussi tre spcifis par le
constructeur.
Si ncessaire, un quipement doit tre fourni par le constructeur pour interprter le signal de
sortie ou lindication et permettre de vrifier la prcision de la fonction de transfert.
4.2.8

Units de commande spares pour utilisation avec un matriel autonome de


dtection de gaz

Une spcification fournie avec le matriel, doit dcrire la relation entre le signal dentre et la
concentration de gaz calcule (fonction de transfert). Cette spcification doit tre
suffisamment dtaille pour que la prcision de cette fonction de transfert puisse tre vrifie.
Au minimum, le constructeur doit fournir les donnes montrant la relation entre le signal de
dentre et la concentration de gaz 0, 10 %, 25 %, 50 %, 75 % et 100 % de lindication
pleine chelle de la sortie. Les entres requises pour lindication pleine chelle et les signaux
dtat (par exemple, dfaut, inhibition) doivent aussi tre spcifis par le constructeur.
Si ncessaire, un quipement doit tre fourni par le constructeur pour interprter le signal
dentre et permettre de vrifier la prcision de la fonction de transfert.
4.2.9

Matriel command par logiciel

Dans la conception de matriel command par logiciel, les risques de dfaut survenant dans
le programme doivent tre pris en compte.
4.2.9.1

Erreurs de conversion

La relation entre les valeurs analogiques et numriques correspondantes doit tre sans
ambigut. La plage des valeurs de sortie doit pouvoir s'adapter la plage complte des
valeurs d'entre dans les limites de la spcification de linstrument. Le dpassement de
ltendue de conversion doit tre indiqu clairement.
La conception doit prendre en compte les erreurs maximales possibles de conversion
analogique/numrique, numrique/analogique et de calcul. Les effets combins des erreurs
de numrisation ne doivent pas dpasser la plus petite drive de l'indication exige par la
prsente norme.
4.2.9.2

Indication dtat spcial

Si le matriel entre dans un tat spcial, cela doit tre indiqu par un signal. Pour le matriel
fixe, cela doit inclure un contact ou un autre signal de sortie transmissible.
4.2.9.3

Logiciel

Les lments relatifs aux logiciels doivent tre conformes ce qui suit:
a) L'utilisateur doit pouvoir identifier les versions de logiciel installes, par exemple par un
marquage sur le composant mmoire install, l'intrieur (si accessible) ou sur le
matriel, ou en les affichant sur l'cran lors de la mise sous tension ou sur demande de
lutilisateur.
b) L'utilisateur ne doit pas pouvoir modifier le code du programme.
c) Les paramtrages doivent faire l'objet d'une vrification. Les entres non valides doivent
tre rejetes. Une barrire d'accs doit tre prvue contre la modification des paramtres
par les personnes non autorises, par exemple en intgrant un code d'accs intrinsque
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

70

60079-29-1 CEI:2007

au logiciel ou en la reprsentant sous la forme d'un verrou mcanique. Le rglage des


paramtres doit tre maintenu aprs la coupure de lalimentation, et pendant le passage
dans un tat spcial. Tous les paramtres modifiables par lutilisateur ainsi que leurs
limites autorises doivent tre lists dans le manuel.
d) La conception du logiciel doit tre structure afin de faciliter les essais et la maintenance.
Sils sont utiliss, les modules de programmes doivent avoir une interface clairement
dfinie par rapport aux autres modules.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

e) La documentation propre au logiciel doit tre incluse dans le dossier technique du produit.
Elle doit comporter:
1) le matriel auquel le logiciel appartient ;
2) l'identification claire de la ou des versions de programme ;
3) la description fonctionnelle ;
4) la structure du logiciel
Schneidermann) ;

(par

exemple

organigramme,

diagramme

de

Nassi-

5) toute modification de logiciel accompagne de la date de modification et des nouvelles


donnes d'identification.
4.2.9.4

Transmission de donnes

La transmission de donnes numriques entre des composants du matriel physiquement


spars doit tre fiable. Les retards rsultant des erreurs de transmission ne doivent pas
augmenter le temps de rponse t 90 ou le dlai de lalarme du matriel uniquement, de plus
dun tiers. Si cest le cas, le matriel doit passer dans un tat spcial dfini. Ltat spcial
dfini doit tre dcrit dans le manuel d'instructions.
4.2.9.5

Auto-test individuel

Les units de calcul numrique doivent possder des auto-tests. A la dtection dune
dfaillance, le matriel doit passer dans un tat spcial dfini. Ltat spcial dfini doit tre
dcrit dans le manuel d'instructions.
Au minimum, le matriel doit effectuer les tests suivants:
a) lalimentation des units numriques doivent tre surveilles un intervalle rgulier
maximum de dix fois le temps de rponse t(90) ou pour les matriels d'alarme
uniquement, de 10 fois le dlai d'alarme,
b) toutes les fonctions de sortie visuelles ou sonores doivent tre testes. Le test doit tre
ralis automatiquement aprs le dbut du fonctionnement ou sur demande de
l'utilisateur. Le rsultat peut ncessiter dtre vrifi par lutilisateur,
c) le dispositif de surveillance avec sa propre base de temps (par exemple, chien de garde)
doit fonctionner indpendamment et sparment des autres parties de lunit numrique
qui effectue le traitement des donnes,
d) la mmoire des programmes et des paramtres doit tre surveille par des procdures qui
permettent la dtection dune erreur d'octet,
e) la mmoire volatile doit tre surveille par des procdures qui testent la lecture et
l'criture des cellules mmoires.
Les essais, lexception de lessai b) doivent tre effectus automatiquement et tre rpts
de faon cyclique au moins toutes les 24 h et la mise sous tension.
4.2.9.6

Concept fonctionnel

Le constructeur doit fournir une documentation permettant lanalyse du concept fonctionnel et


son valuation en utilisant la liste suivante:

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

71

squence de mesure (incluant toutes les variantes possibles),

tats spciaux possibles,

paramtres et leurs tendues de rglage tolres,

reprsentation des valeurs mesures et des indications,

gnration des alarmes et signaux,

extension et ralisation des essais de routine,

extension et ralisation des transmissions distance de donnes.

4.3

Etiquettes et marquage

Le matriel doit tre conforme aux exigences de marquage de la CEI 60079-0.


NOTE Il convient que le matriel lectrique qui nest pas strictement conforme la norme pertinente de la srie
CEI 60079-0 mais revendique un niveau de scurit quivalent soit marqu avec le symbole s .

De plus, le marquage du matriel doit aussi inclure:


a) IEC 60079-29-1 (pour indiquer la conformit avec cette norme daptitude la
fonction) ;
b) anne de construction (peut tre code dans le numro de srie),
4.4

Manuel d'Instruction

Chaque matriel doit tre fourni avec un manuel dinstruction comprenant les informations
suivantes:
a) les instructions compltes, dessins et schmas pour une utilisation correcte et en scurit,
linstallation et lentretien du matriel,
b) les instructions de fonctionnement et procdures de rglage,
c) des recommandations pour le contrle initial et ltalonnage du matriel sur la base dune
routine incluant des instructions pour lutilisation du kit dtalonnage sur site, le cas
chant (voir aussi 5.4.26).
Pour le matriel portable, elles doivent inclure les exigences et la mthode pour raliser le
contrle fonctionnel avec un gaz avant chaque journe dutilisation ;
NOTE

Les utilisateurs se reporteront la CEI 60079-29-2.

d) les dtails des limitations de fonctionnement, si applicables, incluent:


1)

les gaz pour lesquels le matriel est adapt et les sensibilits relatives de
linstrument pour ces gaz,

2)

linformation qui dcrit les ractions aux autres gaz auxquels le matriel est sensible,

3)

les temps de rponse pour le ou les gaz dessai normaliss et les informations qui
dcrivent comment les temps de rponse peuvent varier avec dautres gaz,

4)

les limites de temprature,

5)

les variations de lhumidit,

6)

les limites de pression,

7)

les limites de tension dalimentation,

8)

la puissance maximale consomme,

9)

les caractristiques correspondantes


dinterconnexion requis,

et

dtails

de

10) les donnes de laccumulateur,


11) le dbit dchantillonnage,
12) le temps de prchauffage,
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

construction

des

cbles

72

60079-29-1 CEI:2007

13) le temps de stabilisation,


e) les dtails sur la dure de vie en stockage et des limitations du matriel, les pices de
rechange et accessoires, incluant, si applicable, les lments suivants:

f)

1)

la temprature,

2)

lhumidit,

3)

la pression,

4)

la dure,

les bases utilises pour la conversion (de % LII en % volumique) des concentrations de
gaz dtalonnage et d essai ;

g) des informations sur les effets nfastes des poisons et des gaz ou substances
interfrentes et des atmosphres dficientes ou enrichies en oxygne sur l aptitude la
fonction propre (et, dans le cas datmosphres enrichies en oxygne, sur la scurit
lectrique du matriel);
h) pour le matriel aspiration, lindication de la pression et du dbit minimum et maximum,
galement, le type des tubes, la taille et la longueur maximale pour un fonctionnement
correct;
i)

pour le matriel aspiration, les instructions pour assurer que les lignes dchantillonnage
sont intactes et quun dbit correct est tabli (voir 4.2.4)

j)

les spcifications sur la nature et la signification de toute alarme et signal de panne, leur
dure (si limit en temps ou non verrouill), et toute disposition prise pour arrter ou
enclencher ces alarmes ou signaux, si applicable ;

k) les dtails de toute mthode de dtermination des sources possibles


dysfonctionnement et toute procdure corrective (procdures de recherche de fautes);
l)

de

une dclaration des dispositifs dalarme, sorties ou contacts de type non verrouill, quand
cela est applicable (voir 4.2.3.2);

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

m) pour le matriel fonctionnant sur accumulateur, les instructions pour linstallation et la


maintenance des accumulateurs;
n) une liste de pices de rechange recommandes;
o) lorsque des accessoires optionnels (par exemple, cnes collecteurs, dispositifs de
protection contre les intempries) sont fournis, le constructeur doit lister ces accessoires
et tablir leurs effets sur les caractristiques de linstrument (y compris le temps de
rponse et la sensibilit) et fournir les moyens de leur identification (par exemple, numro
de la pice inclus dans le manuel);
p) les dtails de la certification et du marquage, et toutes conditions particulires de
fonctionnement;
q) lorsque la nature particulire du matriel (telle que des rponses non linaires) ncessite
des instructions supplmentaires, des informations spciales qui sont des alternatives ou
en supplment aux exigences de 4.3 et 4.4 a) p), alors des instructions ou informations
doivent tre donnes.

5
5.1

Mthodes dessai
Introduction

Les procdures et mthodes dessai dcrites de 5.2 5.4 serviront de base pour tablir la
conformit aux exigences supplmentaires dun matriel pour laptitude la fonction donne
dans les limites appropries listes lAnnexe A.
5.2

Exigences gnrales pour les essais

Quand il est ncessaire dappliquer les valeurs LII et LSI dans le cadre de cette norme, elles
doivent tre celles de la CEI 60079-20.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007
5.2.1
5.2.1.1

73

Echantillons et ordre des essais


Gnralits

Pour les besoins des essais de type, les essais doivent tre mens sur un matriel. Dautres
matriels peuvent tre utiliss pour les essais, conformment 5.4.4.2 5.4.4.5, 5.4.18 et
5.4.24.
Pour les capteurs infrarouges utilisant des filtres optiques, lessai 5.4.3.3 doit tre ralis
avec deux matriels o la longueur donde centrale des filtres optiques doit correspondre aux
limites minimale et maximale de la spcification. Une de ces units peut tre utilise par la
suite pour 5.4.4.2 5.4.4.5, 5.4.18 et 5.4.24.
5.2.1.2

Squence

Le matriel doit tre soumis tous les essais applicables ce type de matriel, tels que
dcrits en 5.4.
Lessai 5.4.2 doit tre effectu avant tous les autres essais. Le constructeur peut demander
un ordre particulier pour le droulement des autres essais. Cependant, les essais 5.4.4.2
5.4.4.5, 5.4.18 et 5.4.24 doivent toujours tre raliss dans cet ordre.
5.2.1.3

Matriel de dtection de gaz autonome

Le matriel autonome de dtection de gaz doit tre prouv par rapport aux exigences de
5.4.2 5.4.13, 5.4.15, 5.4.16, 5.4.18, 5.4.20 5.4.27 (si applicable) en utilisant les
paramtres de la fonction de transfert.
5.2.1.4

Units de commande autonomes

Les units de commande doivent tre prouves par rapport aux exigences de 5.4.2, 5.4.3,
5.4.6, 5.4.7, 5.4.13, 5.4.15, 5.4.16, 5.4.18, 5.4.20, 5.4.21, 5.4.25 et 5.4.27 en utilisant les
paramtres de la fonction de transfert pertinente pour le type spcifique de dtecteur de gaz.
5.2.1.5

Echantillon

Lorsque cela est applicable, des essais doivent aussi tre raliss pour garantir que le
matriel est conforme aux exigences de construction de 4.2. Les exigences pour ces essais
sont gnralement videntes, lexception que pour les exigences pour les courts-circuits en
4.2.4, des rsistances de ballast doivent tre substitues pour chaque fil reliant linstrument
tout capteur distance. Les valeurs de ces rsistances sont celles dclares, dans le manuel
dinstruction (voir 4.4 d)), comme tant les rsistances de connexion maximales qui
permettent une conformit satisfaisante la norme. Le dispositif utilis pour le court-circuit
doit tre de rsistance ngligeable et doit tre appliqu en des points accessibles du circuit,
aux extrmits capteur des rsistances de ballast.
5.2.1.6

Echantillon avec une tendue slectionnable

Pour le matriel ayant plus dune tendue ou chelle slectionnable pour le mme ou pour
diffrents gaz ou vapeurs, chaque chelle doit tre prouve. Pour les chelles seconde et
suivantes, le nombre ncessaire dessai doit tre approuv entre le constructeur et le
laboratoire dessai.
5.2.2

Prparation du matriel avant essai

Le matriel doit tre prpar et assembl en accord avec son fonctionnement typique,
conformment aux instructions du manuel, y compris les interconnexions ncessaires, les
rglages et talonnages initiaux. Les rglages peuvent tre effectus, si appropri, au dbut
de chaque essai.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

74

60079-29-1 CEI:2007

En particulier, les points suivants doivent tre nots:


a) Matriel capteurs distance
Pour les besoins des essais en 5.4, o il est fait rfrence lexposition du capteur aux
conditions dessai, le capteur distance en entier (comprenant chaque ou toute partie
mcanique de protection normalement attache) doit tre expos.
Pour le matriel ayant des capacits de connexion de plus dun capteur distance, il
suffira deffectuer les essais sur un seul capteur. Le remplacement de tous les capteurs
sauf pour un capteur, par des impdances fictives simulant les pires conditions de charge
pour lessai en question peut tre autoris. Ces conditions de charge de pire cas doivent
tre dtermines par le laboratoire dessai dans les limites spcifies dans le manuel
dinstruction (voir 4.4 d)).
Pour le matriel ayant un ou des capteurs distance, tous les essais doivent tre
effectus avec des rsistances connectes aux circuits des dtecteurs pour simuler la
rsistance maximale de ligne spcifie par le constructeur, sauf quand, selon le jugement
du laboratoire dessai, la rsistance minimale reprsente les conditions dessai les plus
svres.
b) Matriel capteurs intgrs
Le matriel complet doit tre expos aux conditions dessai sans retrait de parties
normalement attaches, y compris toute sonde dchantillonnage pour les essais 5.4.11,
5.4.15, 5.4.16 et 5.4.17.
c) Matriel alarme uniquement
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Pour le matriel alarme uniquement, les mesures doivent tre prises en utilisant un
instrument de mesure externe connect aux points dessai dcrits en 4.2.2.2.
Dans tous les cas, les parties optionnelles doivent tre attaches ou retires selon la
condition donnant les rsultats les plus dfavorables ( la discrtion du laboratoire dessai)
pour raliser cet essai.
5.2.3

Masque pour talonnage et essais

Lorsquun masque est utilis pour ltalonnage ou pour linjection de gaz dessai dans le
capteur, la conception et le fonctionnement du masque utilis par le laboratoire dessai en
particulier la pression et la vitesse dans le masque ne doivent pas influencer de faon
inadmissible la rponse du matriel ou les rsultats obtenus.
NOTE Il est recommand que le laboratoire dessai consulte le constructeur pour dterminer la conception du
masque dtalonnage. Le constructeur peut fournir un masque dtalonnage adapt en mme temps que les dtails
de dbit ou pression suggr pour lapplication des gaz dtalonnage au matriel.

5.3
5.3.1

Conditions normales dessais


Gnralits

Les conditions dessai spcifies de 5.3.2 5.3.12 doivent tre utilises pour tous les essais
sauf spcification contraire.
5.3.2

Gaz dessai

Les gaz inflammables utiliser dans un mlange dair propre pour les essais initiaux et
conscutifs doivent tre choisis conformment a) ou c) ci-dessous.
a) Le gaz spcifique pour le matriel destin dtecter un seul gaz inflammable.
b) Mthane pour le matriel sensible au mthane ou au grisou, ou destin la dtection de
gaz inflammables en gnral y compris la dtection du mthane.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

75

c) Un gaz dans la gamme des gaz inflammables pour lesquels le constructeur dclare que
son matriel est appropri. Il convient que le choix de ce gaz soit fait par agrment entre
le constructeur et le laboratoire dessai.
NOTE 1 Il est recommand dprouver le matriel ayant des capteurs combustion catalytique destins une
dtection dapplication gnrale incluant le mthane, avec des gaz dessai mthane et propane afin d'obtenir des
rsultats reprsentatifs (par exemple, pour la sensibilit, les temps de rponse, et les carts).
NOTE 2 Il est recommand dprouver le matriel ayant des capteurs IR destins une dtection des
hydrocarbures incluant du mthane, avec des gaz dessai mthane et propane afin d'obtenir des rsultats
reprsentatifs (par exemple, pour la sensibilit).

Pour tous les autres gaz pour lesquels le matriel est considr tre adapt, les courbes
dtalonnage et le temps de rponse doivent tre fournis par le constructeur et un chantillon
reprsentatif vrifi par le laboratoire dessai. Le titre volumique de cette composante dans
leou les gaz dessai doit tre connue avec une incertitude largie relative de 2 % de la
valeur nominale.
NOTE 3 Pour les besoins de cette norme, lorsquil est appropri dutiliser un gaz zro plutt que de lair propre,
les rfrences de lair propre peuvent tre considres comme celles du gaz zro.
NOTE 4 Le mlange de gaz peut tre prpar suivant toute mthode adapte, par exemple en conformit avec
les mthodes dcrites dans lISO 6142 ou dans lISO 6145 ou par des mlanges de gaz certifis disponibles dans
le commerce.

5.3.3

Gaz dessai normalis

Les titres volumiques des gaz dessai normaliss doivent tre les suivants:
a) pour le matriel du groupe I pouvant indiquer jusqu un titre volumique de 5 % de
mthane: une gamme quivalente un titre volumique de (1,5 0,15) % ou un titre
volumique de (2,0 0,2) %, suivant accord entre le constructeur et le laboratoire dessai;
b) pour les autres matriels du groupe I et tous les matriels du groupe II: 45 % 55 % de
lchelle de mesure, quand cela est possible, hors de la gamme explosive. Si cette
concentration est dans la gamme explosive, le gaz inflammable doit tre mlang avec de
l'azote si la fonction de mesure du matriel n'est pas affecte par une dficience
d'oxygne. Sinon, la concentration du gaz dessai normalis doit tre prise hors de la
gamme explosive et aussi proche que possible des valeurs tablies ci-dessus;
Les titres volumiques doivent tre connus avec une incertitude largie relative de 2 %.
5.3.4

Dbit pour gaz dessai

Quand le matriel est expos aux gaz dessai, y compris lair, le dbit du gaz doit tre
conforme aux instructions du constructeur.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

NOTE Pour le matriel qui chantillonne par diffusion, on utilisera soit un masque dtalonnage conformment
5.2.3, soit une chambre dessai (voir aussi Annexe B).

5.3.5

Tension

a) Le matriel aliment par le rseau doit fonctionner aux frquences et tensions


dalimentation recommandes par le constructeur avec une marge de 2 %.
b) Pour des essais court terme, le matriel aliment par accumulateur, doit tre quip
daccumulateurs neufs ou compltement chargs au commencement de chaque srie
dessais. Pour les essais long terme, il est permis de mettre sous tension lunit partir
dune alimentation de puissance stabilise.
5.3.6

Temprature

Durant tout lessai, lair ambiant et le gaz dessai doivent tre maintenus une temprature
constante de 2 K entre 15 C et 25 C, sauf spcification contraire pour l'essai particulier.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

76
5.3.7

60079-29-1 CEI:2007

Pression

Les essais doivent tre effectus une pression entre 86 kPa et 108 kPa avec une drive
maximale de 1 kPa pendant la dure de chaque essai court terme, sauf spcification
contraire pour l'essai particulier. Pour les essais long terme, linfluence des drives de la
pression doit tre prise en compte en utilisant les rsultats de lessai de pression (5.4.8).
5.3.8

Humidit

Lair ambiant et le gaz dessai doivent tre maintenus une humidit relative (RH) contrle
10 % RH sur ltendue de 20 % 80 %, pendant tous les essais, sauf spcification contraire
pour l'essai particulier.
Pour les applications brves de gaz dessai, lutilisation de gaz sec est autorise. Les
proprits du principe de mesure du capteur doivent tre prises en compte.
5.3.9

Temps de stabilisation

Dans chaque exemple o le matriel est soumis une condition dessai diffrente, on doit
laisser le matriel se stabiliser sous ces nouvelles conditions avant que des mesures ne
soient prises.
5.3.10

Orientation

Le matriel doit tre prouv suivant lorientation recommande par le constructeur.


5.3.11

Options de communication

Pour le matriel ayant des options de communications sries ou parallles qui sont utilises
pendant lopration normale de dtection de gaz, les essais de 5.4.3, 5.4.7 et 5.4.16 doivent
tre effectus, tous les accs (ports) de connexions tant connects. Le dbit maximum de
transmission, les caractristiques de cblage et le niveau dactivit spcifis par le
constructeur de linstrument doivent tre employs.
5.3.12

Matriel de dtection de gaz constituant une partie de systme

Pour les matriels de dtection de gaz qui constituent une partie dun systme, les essais de
5.4.3, 5.4.7, 5.4.16 et 5.4.20 doivent tre effectus avec le dbit de transmission de
communication maximum du systme et le niveau maximum dactivit. Ceci doit correspondre
la configuration de systme la plus large et la plus complexe autorise par le constructeur.
5.4
5.4.1

Mthodes dessai
Gnralits

Les essais suivants doivent tre raliss conformment 5.3, sauf indication contraire. Les
essais doivent tous tre effectus. A la fin de chaque essai, les indications doivent tre
releves la fois pour lair propre et pour le gaz dessai normalis, sauf spcification
contraire. Les valeurs des indications utilises pour la vrification de la conformit avec les
normes daptitude la fonction listes lAnnexe A doivent tre les indications finales (voir
3.6.2) des lectures la fois pour lair propre et pour le gaz dessai normalis, moins quil en
soit dcid autrement.
5.4.2

Stockage hors alimentation

Toutes les parties du matriel doivent tre exposes squentiellement aux conditions
suivantes lair propre uniquement:
a) une temprature de (25 3) C pendant 24 h;
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

77

b) une temprature ambiante pour au moins 24 h;


c) une temprature de (60 2) C pendant 24 h;
d) une temprature ambiante pour au moins 24 h;
A chaque temprature, lhumidit de lair propre doit tre telle quil ny a pas de condensation.
Les tempratures ci-dessus peuvent varier uniquement si un accord a t tabli entre le
constructeur et le laboratoire dessai (voir aussi 4.1.2). Lorsque des tempratures autres que
celles listes ci-dessus sont utilises, elles doivent tre consignes dans les documents de
certification.
5.4.3
5.4.3.1

Etalonnage et rglage
Prparation initiale du matriel

Le matriel doit tre talonn et des rglages effectus, si ncessaire, pour obtenir des
indications correctes conformes aux instructions du manuel du constructeur.
5.4.3.2

Courbe dtalonnage

Le matriel doit tre expos au gaz choisi conformment 5.3.2, quatre titres volumiques
distribus de faon gale sur lchelle de mesure, en partant du plus bas et se terminant par
le plus haut des titres volumiques choisis. Cette opration doit tre mene trois fois de suite.
5.4.3.3

Rponse diffrents gaz

Le rapport entre lindication du matriel (avant correction partir des courbes de rponse ou
tables de correction du constructeur) et le titre volumique de gaz obtenu pour chacun des
trois titres volumiques de chaque gaz prouv ne doit pas tre infrieur 0,4 et ne doit pas
tre suprieur 2,0.
5.4.4

Stabilit (matriel rgime continu uniquement)

NOTE Pour ces essais, il convient que les matriels aliments par accumulateur soient aliments quand cela est
possible, partir de leur accumulateur interne, sinon une alimentation externe peut tre utilise.

5.4.4.1

Stabilit court terme

Le matriel doit tre expos six applications de 3 min au gaz dessai normalis, puis une
exposition lair propre pendant 7 min. Les indications doivent tre releves la fin de
chaque exposition lair et au gaz normalis.
5.4.4.2

Stabilit long terme (matriel fixe ou transportable Groupe I uniquement)

Le matriel doit fonctionner en continu en air propre pendant quatre semaines et tre expos
au gaz dessai normalis sur une priode de 8 h intervalles hebdomadaires pendant quatre
semaines. Les indications doivent tre releves avant lapplication, ou aprs la stabilisation et
avant le retrait du gaz dessai normalis.
A la suite de cette dure, lessai suivant doit tre effectu.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Pour le matriel du groupe II, les prcisions des courbes de rponse ou des tableaux de
correction fournis par le manuel du constructeur peuvent tre vrifies en mesurant la
rponse aux gaz reprsentatifs en accord avec 5.3.2 de gaz, au moins trois titres
volumiques diffrents rpartis rgulirement sur ltendue de mesure pour vrifier les
caractristiques des rponses.

78

60079-29-1 CEI:2007

Le matriel doit fonctionner dans un mlange mthane-air de titre volumique 1,0 % (v/v)
0,05 % (v/v) pendant 5 jours, des indications tant prises quotidiennement dans lair propre et
dans le mlange dessai normalis.
5.4.4.3

Stabilit long terme (matriel portable Groupe I uniquement)

Le matriel doit fonctionner en continu en air propre pendant 8 h par jour sur une priode de
20 jours de travail. Le matriel doit tre expos au gaz dessai normalis pendant 1 h pour
chaque priode de fonctionnement. Les indications doivent tre releves avant lapplication,
ou aprs la stabilisation et avant le retrait du gaz dessai normalis.
A la suite de cette dure, lessai suivant doit tre effectu.
Le matriel doit fonctionner dans un mlange mthane-air de titre volumique 1,0 % (v/v)
0,05 % (v/v) pendant 8 h, des indications tant releves quotidiennement dans lair propre et
dans le mlange dessai normalis. Le matriel doit alors tre commut sur la position arrt et
expos lair propre pendant 16 h. Ce cycle doit tre rpt 4 autres fois.
5.4.4.4

Stabilit long terme (matriel fixe ou transportable Groupe II uniquement)

En continu, le matriel doit fonctionner lair propre pour une priode de deux mois. A la fin
de la premire semaine, le matriel doit tre expos au gaz dessai normalis pendant 8 h.
Les indications doivent tre releves avant lapplication, ou aprs la stabilisation de la lecture
et avant le retrait du gaz dessai normalis.
A la fin de chaque autre semaine, le matriel doit tre expos au gaz dessai normalis
jusqu ce que la lecture soit stabilise. Les indications doivent tre releves avant
lapplication et le retrait du gaz dessai normalis.
5.4.4.5

Stabilit long terme (matriel portable Groupe II uniquement)

Le matriel doit fonctionner en continu en air propre pendant 8 h par jour sur une priode de
20 jours de travail. Le matriel doit tre expos au gaz dessai normalis jusqu stabilisation,
une fois pendant chaque priode de fonctionnement. Les indications doivent tre releves
avant lapplication, ou aprs la stabilisation et avant le retrait du gaz dessai normalis.
5.4.5

Stabilit (matriel de lecture intermittente uniquement)

Le matriel doit tre expos lair propre pendant 1 min suivi de 1 min au gaz dessai
normalis. Lopration doit tre rpte 200 fois. Lindication finale sera releve dans lair
propre et dans le gaz dessai normalis, aprs stabilisation la fin de lessai.
NOTE Pour ces essais, il convient que les matriels aliments par accumulateur soient aliments quand cela est
possible, partir de leur accumulateur interne, sinon une alimentation externe peut tre utilise.

5.4.6
5.4.6.1

Point(s) de consigne dalarme


Gnralits

Lorsque le matriel est fourni avec


a) des moyens de rglage externes pour un ou plusieurs point(s) de consigne dalarme, ou
b) des points de consigne dalarme prrgle en interne lactivation de telles alarmes par le
gaz aux valeurs de consigne doit tre vrifie en utilisant des gaz dessai comme dcrit en
5.4.6.2 et 5.4.6.3. Dans tous les cas, le gaz dessai doit tre appliqu soit jusqu
lactivation de lalarme, soit jusqu deux fois t(90), la valeur la plus faible devant tre
prise en compte.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

79

Pour le matriel ayant plusieurs points de rglage de lalarme, ces essais doivent tre
raliss pour chaque point de consigne de lalarme.
5.4.6.2

Concentration croissante

Pour le matriel de type a), tablir le point de consigne de lalarme 10 % relatif en dessous
de la concentration du gaz dessai normalis. Si le point de consigne de lalarme ne peut pas
tre tabli cette concentration, lalarme doit tre rgle aussi proche que possible de cette
concentration. Dans ce cas et pour le matriel de type b), le gaz dessai doit avoir un titre
volumique de 10 % relatif au-dessus de la concentration du point de consigne de lalarme.
Exposer le matriel lair propre et ensuite au gaz dessai normalis ou au gaz dessai
spcifi.
5.4.6.3

Concentration dcroissante

Pour le matriel de type a), tablir le point de consigne de lalarme 5 % de ltendue de


mesure. Si le point de consigne de lalarme ne peut pas tre tabli cette concentration,
lalarme doit tre rgle aussi proche que possible de cette concentration. Dans ce cas et
pour le matriel de type b), le gaz dessai doit avoir un titre volumique correspondant au point
de consigne de lalarme moins 5 % de ltendue de mesure. Exposer le matriel au gaz
dessai normalis et ensuite lair propre ou au gaz dessai spcifi.
5.4.7

Temprature

Lessai doit tre men dans une chambre de temprature ayant la capacit de maintenir le
capteur ou le matriel la temprature spcifie 2 C. Quand le matriel (ou la partie sous
essai) atteint la temprature spcifie dans lAnnexe A, selon le cas, le capteur doit tre
expos squentiellement lair et au gaz dessai normalis, qui doivent tre la mme
temprature que latmosphre dans la chambre dessai. Le point de rose de lair ou du gaz
dessai normalis doit tre infrieur la temprature la plus basse de la chambre dessai et
gard constant pendant lessai.
5.4.8

Pression

Les effets des drives de pression doivent tre observs en plaant le capteur ou le matriel
(y compris le dispositif daspiration pour le matriel aspiration) dans une chambre dessai
qui permet de faire varier la pression de lair propre et du gaz dessai normalis de varier.
La pression doit tre maintenue aux niveaux spcifis pendant 5 min, avant quune lecture
soit accepte ou quun essai ne soit fait. Les lectures doivent tre prises avec lair propre et
avec le gaz dessai normalis.
5.4.9

Humidit

Lessai doit tre ralis avec trois niveaux dhumidit rpartis rgulirement sur ltendue
spcifie lAnnexe A. Le matriel doit tre stabilis 40 C. Aprs stabilisation, il doit tre
rgl conformment aux instructions du constructeur. Pour chaque niveau dhumidit, le
matriel doit tre expos pendant 15 min lair propre et ensuite au gaz dessai normalis
avec le mme niveau dhumidit. Les niveaux dhumidit relatifs doivent tre connus 3 %
RH.
La concentration du gaz dessai doit tre tenue constante, ou les ajustements rendus
ncessaires par sa drive doivent tre effectus par dilution dans de leau.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

80
5.4.10
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5.4.10.1

60079-29-1 CEI:2007

Vitesse de lair
Gnralits

Les effets de la vitesse de lair entre 0 m/s 6 m/s sur un matriel avec des capteurs qui
fonctionnent par diffusion doivent tre dtermins en utilisant les conditions dessai donnes
en 5.4.10.2.
5.4.10.2

Conditions d'essai

Les capteurs du matriel ayant des capteurs distance et si applicable, le matriel en entier
si les capteurs sont intgrs, doivent tre prouvs dans une chambre de flux.
NOTE Il convient que la chambre de flux soit approprie lapplication de lair propre et du gaz dessai
normalis.

Dans le cas de matriel avec des capteurs intgrs trop volumineux pour tre prouvs dans
une chambre de flux, dautres matriels de flux doivent tre autoriss pour mener les essais.
Quelque soit la chambre de flux ou lautre matriel utilis, orienter le capteur dans la direction
du flux d'air comme ci-aprs:
1) capteur orient directement face au flux,
2) capteur orient loign de la direction du flux,
3) capteur orient perpendiculairement au flux.
Les mesures doivent tre effectues dans des conditions statiques, 3 m/s et 6 m/s.
NOTE Les directions du flux qui sont improbables en pratique, de par la conception du matriel, ou qui sont
expressment interdites par le manuel dinstruction du constructeur ne peuvent pas tre prouves.

5.4.11

Dbit pour le matriel daspiration

Le matriel doit tre prouv en faisant varier le dbit


1) de 130 % du dbit nominal ou, si cela est possible, du dbit nominal,
2) au dbit nominal auquel lalarme de dfaillance est tablie ou 50 % du dbit nominal si
aucune alarme de dfaillance nest fournie.
5.4.12
5.4.12.1

Orientation
Matriel portable

Pendant chaque essai avec lair propre et avec le gaz dessai, tourner le capteur, ou le
matriel si applicable, sur 360, par pas de 90 autour de chacun de ses trois axes
perpendiculaires (un axe la fois). Enregistrer lindication pour chaque position.
5.4.12.2

Matriel fixe et transportable

Eprouver le capteur, ou le matriel ayant un capteur intgr, avec lair propre et le gaz dessai
normalis dans les limites dorientation tablies par les instructions du constructeur, mais en
aucun cas moins de 15 de lorientation nominale.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007
5.4.13

81

Vibration

5.4.13.1

Equipement dessai

La machine pour essai de vibration consiste en une table vibrante capable de produire une
vibration de frquence variable et un dplacement constant variable (crte crte); avec le
matriel dessai mont sur place, comme exig par les procdures dessai suivantes.
5.4.13.2

Procdure

Le matriel doit tre sous tension et mont sur la machine pour essai de vibration et subir des
vibrations successivement dans chacun des trois plans respectivement parallles aux bords
du matriel.
Le point de consigne de lalarme doit tre tabli 20 % de la pleine chelle de l'tendue.
Avant et la fin de lessai, le matriel doit tre expos lair propre suivi du gaz dessai
normalis.
Le matriel doit tre mont sur la table de vibration de la mme faon que pour son utilisation
y compris tout montage solidaire, dispositif pour le tenir ou le porter qui sont fournis comme
parties normalises du matriel.
Le matriel doit subir des vibrations sur toute ltendue de frquence dfinie lamplitude ou
la pointe dacclration constante spcifie, pour une dure de 1 h dans chacun des trois
plans mutuellement perpendiculaires. La variation de frquence ne doit pas dpasser 10
Hz/min.
5.4.13.2.1

Procdure 1

Pour le matriel portable et transportable, les capteurs distance et les units de commande
pour lesquels les capteurs sont intgrs o directement fixs lunit de commande, les
vibration doivent tre comme ci-dessous:
10 Hz 30 Hz, 1,0 mm damplitude totale;
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

31 Hz 150 Hz, pointe dacclration 19,6 m/s .


5.4.13.2.2

Procdure 2

Pour les units de commande installes distance des capteurs, les vibrations doivent tre
les suivantes:
10 Hz 30 Hz, 1,0 mm damplitude totale;
2

31 Hz 100 Hz, pointe dacclration 19,6 m/s .


5.4.14

Essai de chute pour matriel portable et transportable

Cet essai est applicable au matriel portable ou transportable. Si le constructeur recommande


que linstrument soit utilis dans sa housse de transport, lessai doit se faire avec la housse
uniquement.
NOTE Si des composants dun matriel fixe peuvent tre utiliss comme des matriels portables ou
transportables conformment au manuel dinstruction, il convient que ces composants soient considrs, dans le
cadre de cet essai, comme des matriels portables ou transportables.

Avant et la fin de lessai, le matriel doit tre expos lair propre suivi du gaz dessai
normalis.
Le matriel portable doit tre lch, en fonctionnement, dune hauteur de 1 m en chute libre
sur une surface en bton.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

82

60079-29-1 CEI:2007

Le matriel transportable de moins de 5 kg doit tre lch, hors fonctionnement, dune


hauteur de 0,3 m en chute libre sur une surface en bton.
Les autres matriels transportables doivent tre lchs, hors fonctionnement, dune hauteur
de 0,1 m en chute libre sur une surface en bton.

Le matriel doit tre considr comme dfaillant pour cet essai sil y a perte dune fonction
(par exemple, alarme, pompage, commandes, affichage) aprs lessai.
5.4.15

Temps d'chauffement

Le point de consigne de lalarme doit tre tabli 20 % de l'tendue de mesure.


Le matriel doit tre teint et laiss lair propre pendant 24 h. Aprs ce dlai de 24 h, le
matriel doit tre allum lair propre et le temps dchauffement mesur.
Le matriel de groupe I, hormis le matriel lecture intermittente, doit tre teint pour 24 h
supplmentaire lair propre. Pass ce dlai, le matriel doit tre expos pendant 5 min au
gaz dessai normalis, et allum en prsence du gaz dessai et le temps dchauffement doit
tre mesur.
5.4.16

Temps de rponse (non applicable au matriel lecture intermittente)

Le matriel doit tre mis en marche en air propre et, aprs un intervalle correspondant au
moins deux fois le temps dchauffement, tel que dtermin en 5.4.15, sans mise larrt, le
matriel ou les capteurs doivent tre soumis des variations chelonnes de lair propre vers
le gaz dessai normalis et de celui-ci vers l'air propre. Ces variations doivent tre introduites
laide dun dispositif adquat (voir Annexe B).
Les temps de rponse t(50) et t(90) pour la concentration croissante, et t(50) et t(10) pour la
concentration dcroissante doivent tre mesurs.
Les temps de rponse doivent tre appliqus au matriel dans les conditions telles que
fournies et sans accessoires en option, par exemple des cnes collecteurs, des protections
contre les intempries attachs au capteur pour des besoins spcifiques.
En cas dutilisation dune sonde par chantillonnage optionnelle, un essai supplmentaire est
exig pour mesurer le retard ajout. Celui-ci doit tre infrieur 3 s/m de la longueur totale
de la sonde et des tubes ou toute autre valeur mentionne dans le manuel dinstruction.
5.4.17

Temps minimal de fonctionnement (matriel lecture intermittente)

Le gaz dessai normalis doit tre appliqu au matriel simultanment linitiation de la


procdure de mesure.
Lair propre doit tre appliqu au matriel simultanment linitiation de la procdure de
mesure.
5.4.18

Concentration leve de gaz au-dessus de ltendue de mesure

Ce paragraphe sapplique tous les matriels ayant une limite suprieure de ltendue de
mesure infrieure 100 % (v/v) de gaz.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Lessai exig ci-dessus doit tre ralis sparment en trois fois, le matriel portable tant
lch chaque fois avec une face (surface) diffrente oriente vers le sol au moment du lch
et le matriel transportable tant lui lch dans une position normale de transport.

60079-29-1 CEI:2007

83

Le matriel complet, ou les capteurs distance des matriels transportables ou fixes, doivent
tre soumis aux essais donns en 5.4.18.1 ou 5.4.18.2, en utilisant un matriel dessai qui
simule une variation chelonne des concentrations de gaz telles que dcrites lAnnexe
B.
Toutes les concentrations de gaz au-dessus de la pleine chelle doivent tre indiques par un
indicateur de dpassement de pleine chelle et si le matriel en est quip, par une alarme.
Si lindication est digitale, il convient de donner une indication claire que la limite suprieure
de ltendue de mesure a t dpasse.
5.4.18.1

Matriel lecture intermittente

Le matriel doit tre soumis 50 cycles, chaque cycle comportant une exposition un titre
volumique de 100 % (v/v) de gaz pour le temps minimal de fonctionnement, suivi par une
exposition lair propre pour le temps minimal de fonctionnement. Aprs le cycle final, le
matriel doit fonctionner cinq fois lair propre, chaque fois dune dure quivalent au
minimum de temps de fonctionnement, puis le matriel doit tre soumis au gaz dessai
normalis.
5.4.18.2

Matriel autre que le matriel lecture intermittente

Le matriel, ou capteur distance, doit tre soumis un remplacement de lair propre par un
titre volumique de 100 % (v/v) de gaz qui doit tre maintenu pendant 3 min. Le capteur doit
alors tre soumis lair propre pendant 20 min, suivi du gaz dessai normalis.
5.4.19

Capacit de laccumulateur

5.4.19.1
5.4.19.1.1

Matriel portable rgime continu aliment par accumulateur


Dcharge daccumulateur

Avec un accumulateur compltement recharg au dbut de lessai, le matriel doit fonctionner


lair propre pendant une priode totale de
a) 8 h, sil est quip dun interrupteur on/off sur lequel lutilisateur peut intervenir,
b) 10 h, sil nen est pas quip, ou
c) toute dure plus longue telle que spcifie par le constructeur.
A la fin de la priode concerne, le matriel est expos au gaz dessai normalis.
5.4.19.1.2

Dure en condition daccumulateur faible

Le matriel doit continuer fonctionner jusqu lindication que les conditions daccumulateur
faibles sont atteintes. Le matriel doit continuer fonctionner pendant encore 10 min.
5.4.19.2
5.4.19.2.1

Matriel lecture intermittente portable aliment par accumulateur


Dcharge daccumulateur

Avec un accumulateur compltement recharg au dbut de lessai, le matriel doit fonctionner


lair propre 200 fois.
La dure de chaque opration doit tre quivalente au temps minimal de fonctionnement, 1
min devant scouler entre chaque opration.
A la fin des 200 oprations, le matriel doit tre expos au gaz dessai.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

84
5.4.19.2.2

60079-29-1 CEI:2007

Dure en condition de faiblesse de laccumulateur

Le cycle des oprations doit continuer jusqu ce quune indication prcise que les conditions
de faiblesse daccumulateurs ont t atteintes. Le matriel doit fonctionner encore 10 fois.
5.4.20

Drives de lalimentation de puissance

Le matriel doit tre rgl dans des conditions normales (voir 5.3), une tension
dalimentation nominale et si appropri, une frquence assigne. Pour le matriel avec des
capteurs distance, lessai doit tre effectu avec les rsistances minimale et maximale du
cble dinterconnexion. Le matriel doit alors tre soumis aux essais qui suivent.
Ltalonnage du matriel doit tre vrifi 115 % et 80 % de la tension dalimentation
nominale.
Lorsque le constructeur du matriel spcifie une tendue dalimentation autre que celles
spcifies ci-dessus, le matriel doit tre prouv aux limites suprieure et infrieure de la
tension dalimentation spcifie par le constructeur.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Le fonctionnement correct de toutes les fonctions de sortie la tension dalimentation


minimale doit tre vrifi, y compris dans les conditions de charge maximales.
NOTE 1

Cela inclut les essais des sorties analogiques la charge maximale et au courant maximal.

NOTE 2 Cela inclut les essais pour montrer que les relais sont capables dtre actionns dans la condition de
tension dalimentation minimale.

5.4.21
5.4.21.1

Interruptions de lalimentation de puissance, transitoires et drives de tension


Gnralits

Le matriel doit tre configur sous des conditions normales, en accord avec 5.3, et soumis
alors aux essais spcifis en 5.4.21.2 5.4.21.4 uniquement en air propre.
Le point de consigne de lalarme doit tre tabli 20 % de l'tendue de mesure.
5.4.21.2

Micro-coupure de lalimentation

Lalimentation lectrique doit tre interrompue pendant 10 ms, ceci tant rpt 10 fois des
intervalles de temps alatoires ayant une valeur moyenne de 10 s.
5.4.21.3

Transitoires de tension

Le matriel doit tre prouv conformment la CEI 61000-4-4, essai de svrit 2. La


procdure dessai pour les essais de type raliss en laboratoire doit tre utilise. La dure
de lessai doit tre de 1 min pour chaque ligne ou bornier prouver.
5.4.21.4

Variations chelonnes de tension sans interruption

Pour les matriels aliments par une source c.a. ou externe c.c., la tension dalimentation doit
tre augmente de 10 % et maintenue cette valeur jusqu la stabilisation du matriel, et
ensuite rduite 15 % au-dessous de la tension nominale. Chaque chelon de variation doit
tre ralis en 10 ms.
5.4.22

Ajout dune sonde dchantillonnage

Lorsquil est prvu dajouter une sonde dchantillonnage, le matriel doit tout dabord tre
talonn en utilisant lair et le gaz dessai normalis sans sonde dchantillonnage. La sonde

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

85

dchantillonnage doit ensuite tre ajoute, et lair propre et le gaz dessai normalis
nouveau appliqus.
--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

5.4.23

Poussire (pour matriel o lair est mis en chantillon uniquement par


diffusion naturelle)

Leffet de la poussire doit tre simul en rduisant uniformment lentre de gaz du matriel
par 50 % avant de le soumettre lair propre ou au gaz dessai normalis.
5.4.24
5.4.24.1

Poisons et autres gaz


Poisons (applicable uniquement au matriel du groupe I capteurs
catalytiques ou semiconducteur)

Le matriel doit tre expos un titre volumique de 1 % de mthane dans un mlange dair
contenant un titre volumique de 10 10 - 6 de hexamethydisiloxane et fonctionn en continu
pendant 40 min pour le matriel rgime continu, ou 100 essais pour le matriel lecture
intermittente.
Certains matriaux prsents en atmosphres industrielles peuvent entraner un
empoisonnement ou autres effets indsirables qui peuvent rsulter en une modification de
la sensibilit dun capteur de gaz.
NOTE Des amliorations des tolrances ces matriaux tant souvent dclares par les constructeurs, des
preuves de la procdure dessai utilise pour justifier ces dclarations et les rsultats des essais seront tendus
la validation ou la vrification par un accord entre lacheteur, le constructeur et le laboratoire dessai. Les agents
dempoisonnement possibles et leurs effets sur laptitude la fonction dun capteur sont dcrits dans la
CEI 60079-29-2.

5.4.24.2

Autres gaz

Le matriel doit tre prouv sparment avec les mlanges gazeux suivants:
a) pour le matriel du groupe I pouvant indiquer jusqu un titre volumique de 5 % de
mthane
1) un titre volumique de mthane du gaz dessai normalis + un titre volumique de 13 %
doxygne dans de lazote,
2) un titre volumique de mthane du gaz dessai normalis + un titre volumique de 5 % de
dioxyde de carbone dans lair,
3) un titre volumique de mthane du gaz dessai normalis + un titre volumique de
0,075 % dthane dans lair,
b) pour le matriel du groupe I pouvant indiquer jusqu un titre volumique de 100 % de
mthane
1) un titre volumique de 50 % de mthane + un titre volumique de 6,5 % doxygne dans
de lazote,
2) un titre volumique de 50 % de mthane + un titre volumique de 5 % de gaz carbonique
dans lair,
3) un titre volumique de 50 % de mthane + un titre volumique de 2,5 % dthane dans
lair.
Les mlanges de gaz peuvent tre prpars par toute mthode valable. Les tolrances sur les
titres volumiques de chaque composition doivent tre de 10 % de leur concentration
nominale.
Le titre volumique de chaque composition doit tre connue avec une incertitude largie
relative de 2 % de la valeur tablie.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

86
5.4.25

60079-29-1 CEI:2007

Immunit lectromagntique

Le matriel, incluant le capteur et le systme d'interconnexion, doit tre soumis une


mthode dessai utilise en essai dimmunit CEM rayonne conformment la CEI 61000-41 et la CEI 61000-4-3.
Les exigences d'essai doivent tre celles du niveau de svrit 2, avec un champ de 3 V/m.
NOTE Des paramtres dessai dimmunit lectromagntique plus svres peuvent tre exigs pour des
applications spcifiques ou pour des rglementations locales.

Le point de consigne de lalarme doit tre tabli 20 % de l'tendue de mesure.


Lessai doit tre effectu en air propre.
Dans le cas de systmes en exploitation utilisant des capteurs distance et o lunit de
commande est destine un montage standard en rack, une telle unit de commande doit
tre soumise ces essais en tant place dans lenveloppe fournie par le constructeur.
Le manuel dinstructions doit informer lutilisateur sur le fait quun tel matriel doit tre utilis
avec le mme type denveloppe pour viter des effets lectromagntiques nfastes.
NOTE

5.4.26

Des exigences dmission lectromagntiques peuvent tre exiges par dautres normes.

Kit dtalonnage de terrain

Si un kit dtalonnage de terrain est fourni avec le matriel, faire lessai suivant:
a) talonner le matriel suivant 5.4.3.1 en utilisant les conditions dessai donnes en 5.3 et
lquipement dessai pour les essais dcrits en 5.4,
b) utiliser le kit dtalonnage de terrain conformment aux instructions du constructeur pour
vrifier le temps de rponse du matriel.
5.4.27

Vrification du logiciel

Les fonctions du matriel contrl par logiciel doivent tre values et prouves
conformment 4.2.9.

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Stabilit, long terme


(fixe/transportable)

Stabilit, long terme


(portable)

Stabilit (matriel de
lecture intermittente
uniquement)

Point(s) de consigne
dalarme

Temprature
(portable/transportable)

5.4.4 (b)

5.4.4 (c)

5.4.5

5.4.6

5.4.7 (a)

Rponse dautres gaz

5.4.3.3

Stabilit, court terme

Courbe dtalonnage

5.4.3.2

5.4.4 (a)

Stockage hors
alimentation

Essai

5.4.2

Paragraphe

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

0,2 % mthane ou
10 % de lindication 20 C
(essai : 10 C, 20 C, 40 C)

Contrle de lalarme/fonction
de linitialisation manuelle

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

Non applicable

0,1 % mthane ou
5 % de lindication

Aucun

5 % mthane ou
10 % de lindication 20 C
(essai : 10 C, 20 C, 40 C)

Contrle de lalarme/fonction
de linitialisation manuelle

3 % mthane ou
5 % de lindication

3 % mthane ou
5 % de lindication

3 % mthane ou
5 % de lindication

3 % mthane ou
5 % de lindication

Non applicable

3 % mthane ou
5 % de lindication

Aucun

5 % de ltendue de mesure ou
10 % de lindication 20 C
(essai : - 10 C, 20 C, 40 C)

Contrle de lalarme/fonction de
linitialisation manuelle

5 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

7 % de ltendue de mesure ou
20 % de lindication

3 % de ltendue de mesure ou
10 % de lindication

7 % de ltendue de mesure ou
15 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

Aucun

Indication de titre volumique


jusqu 100 % de la limite
infrieure dinflammabilit

5 % de ltendue de mesure ou
10 % de lindication 20 C
(essai : - 10 C, 20 C, 40 C)

Contrle de lalarme/fonction de
linitialisation manuelle

3 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

7 % de ltendue de mesure ou
20 % de lindication

3 % de ltendue de mesure ou
10 % de lindication

7 % de ltendue de mesure ou
15 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

Aucun

Indication de titre volumique


jusqu 100 % de gaz

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 100 % de mthane
dans lair

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 5 % de mthane dans
lair

Limites pour le matriel du groupe II

Limites pour le matriel du groupe I

Tableau A.1 Exigences daptitude la fonction

Exigences daptitude la fonction

Annexe A
(normative)

60079-29-1 CEI:2007
87

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Pression

Humidit

Vitesse de lair

Dbit

Orientation

5.4.9

5.4.10

5.4.11

5.4.12

(fixe avec capteur)

Temprature

(fixe avec capteur


distance)

Temprature

Essai

5.4.8

5.4.7 (c)

5.4.7 (b)

Paragraphe

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

0,2 % mthane ou
15 % de lindication au
rglage 40 C
(essai: 20%RH, 50%RH,
90%RH)

0,2 % mthane ou
30 % de lindication
100 kPa
(essai: 80 kPa, 100 kPa,
120 kPa)

0,2 % mthane ou
10 % de lindication 20 C
(essai: 10 C, 20 C, 40 C)

0,2 % mthane ou
10 % de lindication 20 C
(essai: 10 C, 20 C, 40 C)

3 % mthane ou
5 % de lindication

Fixe/transportable :

5 % mthane ou
10 % de lindication

Portable:

3 % mthane ou
5 % de lindication

3 % mthane ou
5 % de lindication

5 % mthane ou
15 % de lindication au
rglage 40 C
(essai: 20%RH, 50%RH,
90%RH)

5 % mthane ou
30 % de lindication
100 kPa
(essai: 80 kPa, 100 kPa,
120 kPa)

5 % mthane ou
10 % de lindication 20 C
(essai: 10 C, 20 C, 40 C)

5 % mthane ou
10 % de lindication 20 C
(essai: 10 C, 20 C, 40 C)

Indication de titre volumique


jusqu 100 % de mthane
dans lair

5 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

10 % de ltendue de mesure ou
30 % de lindication au rglage
40 C
(essai: 20%RH, 50%RH, 90%RH)

5 % de ltendue de mesure ou
30 % de lindication 100 kPa
(essai: 80 kPa, 100 kPa, 120 kPa)

5 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

5 % de ltendue de mesure ou
10 % de lindication

10 % de ltendue de mesure ou
30 % de lindication au rglage
40 C
(essai: 20%RH, 50%RH, 90%RH)

5 % de ltendue de mesure ou
30 % de lindication 100 kPa
(essai: 80 kPa, 100 kPa, 120 kPa)

5 % de ltendue de mesure ou
15 % de lindication 20 C
(essai: 10 C, 20 C, 55 C)

Unit de commande:
3 % de ltendue de mesure ou
10 % de lindication 20 C
(essai: 5 C, 20 C, 55 C)

Unit de commande:
3 % de ltendue de mesure ou
10 % de lindication 20 C
(essai: 5 C, 20 C, 55 C)
5 % de ltendue de mesure ou
15 % de lindication 20 C
(essai: 10 C, 20 C, 55 C)

10 % de ltendue de mesure ou
20 % de lindication 20 C
(essai: 25 C, 20 C, 55 C)

Capteur :

Indication de titre volumique


jusqu 100 % de gaz

10 % de ltendue de mesure ou
20 % de lindication 20 C
(essai: 25 C, 20 C, 55 C)

Capteur :

Indication de titre volumique


jusqu 100 % de la limite
infrieure dinflammabilit

(la valeur la plus leve tant retenue)

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 5 % de mthane dans
lair

Limites pour le matriel du groupe II

Limites pour le matriel du groupe I

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Tableau A.1 (suite)

88
60079-29-1 CEI:2007

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

Concentration leve
de gaz au-dessus de
ltendue de mesure

t(10) en moins de 30 s

t(10) en moins de 90 s

(concentration
dcroissante)

5.4.18

t(50) en moins de 10 s

t(50) en moins de 30 s

Temps de rponse

0,2 % mthane ou
+20 %/ -10 % de lindication

5 % mthane ou
10 % de lindication

Lindication 90 % de la valeur
finale doit tre atteinte dans
les 30 s, pour chaque gaz

t(90) en moins de 30 s

t(90) en moins de 30 s

(concentration
croissante)

Lindication 90 % de la valeur
finale doit tre atteinte dans
les 30 s, pour chaque gaz

t(50) en moins de 10 s

t(50) en moins de 10 s

Temps de rponse

Dlai minimal pour


fonctionner

5 % de ltendue de mesure
dans les 2 min, et pas de fausse
alarme

5 % de ltendue de mesure dans


les 2 min, et pas de fausse alarme

3 % mthane dans les 2 min,


et pas de fausse alarme

0,1 % mthane dans les 2


min, et pas de fausse alarme

7 % de ltendue de mesure ou
+20 %/ -10 % de lindication

Lindication 90 % de la valeur
finale doit tre atteinte dans les 30
s, pour chaque gaz

Non applicable

t(90) en moins de 60 s

7 % de ltendue de mesure ou
15 % de lindication

Lindication 90 % de la valeur
finale doit tre atteinte dans les
30 s, pour chaque gaz

t(10) en moins de 60 s

t(50) en moins de 20 s

t(90) en moins de 60 s

t(50) en moins de 20 s

Matriel portable rgime


continu :

Matriel portable rgime


continu :

Matriel portable rgime


continu :

Matriel portable rgime


continu :

t(50) en moins de 20 s

5 % de ltendue de mesure de
la spcification, et pas de fausse
alarme

5 % de ltendue de mesure de la
spcification, et pas de fausse
alarme

3 % mthane dans les 5 min,


et pas de fausse alarme

0,1 % mthane dans les 5


min, et pas de fausse alarme

5.4.17

5.4.16

5.4.16

Fixe/transportable :

Fixe/transportable :

Fixe/transportable :

5 % de ltendue de mesure ou
10 % de lindication, et pas de
perte de la fonction, pas de signal
de panne, pas de dommage
conduisant un danger et non
fausse alertes

Fixe/transportable :

Temps d'chauffement

5.4.15

5 % de l tendue de mesure ou
10 % de lindication, et pas de
perte de la fonction, pas de signal
de panne, pas de dommage
conduisant un danger et non
fausse alertes

Indication de titre volumique


jusqu 100 % de gaz

5 % de ltendue de mesure ou
10 % de lindication

0,1 % mthane ou
5 % de lindication

3 % mthane ou
5 % de lindication, et pas de
perte de la fonction, pas de
signal de panne, pas de
dommage conduisant un
danger et non fausse alertes

Indication de titre volumique


jusqu 100 % de la limite
infrieure dinflammabilit

5 % de ltendue de mesure ou
10 % de lindication

Essai de chute

5.4.14

0,1 % mthane ou
5 % de lindication, et pas de
perte de la fonction, pas de
signal de panne, pas de
dommage conduisant un
danger et non fausse alertes

Indication de titre volumique


jusqu 100 % de mthane
dans lair

(la valeur la plus leve tant retenue)

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 5 % de mthane dans
lair

Limites pour le matriel du groupe II

Limites pour le matriel du groupe I

3 % mthane ou
5 % de lindication

Vibration

5.4.13

Essai

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Paragraphe

Tableau A.1 (suite)

60079-29-1 CEI:2007
89

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Drives de
lalimentation lectrique

Interruptions de
lalimentation de
puissance, transitoires
et drives de tension

Ajout dune sonde


dchantillonnage

Poussire

Poisons

5.4.21

5.4.22

5.4.23

5.4.24.1

Capacit de
laccumulateur

Essai

5.4.20

5.4.19

Paragraphe

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

3 % mthane ou
10 % de lindication

t(90) augmente moins de 10 s

t(90) augmente moins de 10 s

0,2 % mthane ou
10 % de lindication

5 % mthane ou
10 % de lindication

3 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

0,1 % mthane ou
5 % de lindication

Pas dalarme parasite

6 % mthane ou
10 % de lindication 10 min
aprs la condition
accumulateur faible

0,2 % mthane ou
10 % de lindication 10 min
aprs la condition
accumulateur faible

Pas dalarme parasite

3 % mthane ou
5 % de lindication 200
oprations)

0,1 % mthane ou
5 % de lindication 200
oprations)

3 % mthane ou
5 % de lindication

Matriel lecture intermittente

Matriel lecture intermittente

0,1 % mthane ou
5 % de lindication

6 % de ltendue de mesure ou
20 % de lindication 10 min
aprs la condition accumulateur
faible

7 % de ltendue de mesure ou
15 % de lindication 10 min aprs
la condition accumulateur faible

6 % mthane ou
10 % de lindication 10 min
aprs la condition
accumulateur faible

0,2 % mthane ou
10 % de lindication 10 min
aprs la condition
accumulateur faible

Non applicable

Non applicable

5 % de ltendue de mesure ou
10 % de lindication

Pas dalarme parasite

5 % de ltendue de mesure ou
10 % de lindication

7 % de ltendue de mesure ou
15 % de lindication 10 min aprs
la condition accumulateur faible

5 % de ltendue de mesure ou
10 % de lindication 200
oprations)

Non applicable

Non applicable

5 % de ltendue de mesure ou
10 % de lindication

Pas dalarme parasite

3 % de ltendue de mesure ou
10 % de lindication

6 % de ltendue de mesure ou
20 % de lindication 10 min
aprs la condition accumulateur
faible

3 % de ltendue de mesure ou
10 % de lindication 200
oprations)

Matriel lecture intermittente

3 % de ltendue de mesure ou
10 % de lindication (essai: 8 h
ou 10 h, respectivement)

5 % de ltendue de mesure ou
10 % de lindication (essai:8 h ou
10 h, respectivement)

3 % mthane ou
5 % de lindication (essai:8 h
ou 10 h, respectivement)

0,1 % mthane ou
5 % de lindication (essai:8 h
ou 10 h, respectivement)

Matriel lecture intermittente

Portable en rgime continu:

Portable en rgime continu:

Indication de titre volumique


jusqu 100 % de gaz

Portable en rgime continu:

Indication de titre volumique


jusqu 100 % de la limite
infrieure dinflammabilit

Portable en rgime continu:

Indication de titre volumique


jusqu 100 % de mthane
dans lair

(la valeur la plus leve tant retenue)

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 5 % de mthane dans
lair

Limites pour le matriel du groupe II

Limites pour le matriel du groupe I

Tableau A.1 (suite)

90
60079-29-1 CEI:2007

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Autres gaz

Immunit
lectromagntique

Kit dtalonnage de
terrain

5.4.25

5.4.26

Essai

5.4.24.2

Paragraphe

0,1 % mthane ou
5 % de lindication

Drive infrieure 0,1 %


mthane et pas dalarme
parasite

10 % du titre volumique rel


de mthane appliqu

3 % mthane ou
5 % de lindication

Drive infrieure 3 %
mthane et pas dalarme
parasite

10 % du titre volumique rel


de mthane appliqu

Indication de titre volumique


jusqu 100 % de mthane
dans lair

5 % de ltendue de mesure ou
10 % de lindication

Drive infrieure 5 % de
ltendue de mesure et pas
dalarme parasite

Non applicable

Indication de titre volumique


jusqu 100 % de la limite
infrieure dinflammabilit

5 % de ltendue de mesure ou
10 % de lindication

Drive infrieure 3 % mthane


et pas dalarme parasite

Non applicable

Indication de titre volumique


jusqu 100 % de gaz

(la valeur la plus leve tant retenue)

(la valeur la plus leve tant retenue)

Indication de titre volumique


jusqu 5 % de mthane dans
lair

Limites pour le matriel du groupe II

Limites pour le matriel du groupe I

Tableau A.1 (suite)

60079-29-1 CEI:2007
91

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

92

60079-29-1 CEI:2007

Annexe B
(informative)
Dtermination du temps de rponse

B.1

Matriel aspiration (voir aussi Figure B.1)

Le matriel est fix lquipement, par exemple tel que le montre schmatiquement la
Figure B.1.
Si le fonctionnement Marche/Arrt est indpendant de la commande de laspirateur, le
matriel est mis sur marche et stabilis.
La vanne double est rgle pour connecter le matriel au rservoir dair propre. Laspiration
durera jusqu stabilisation du matriel. Le contrle du zro matriel est rgl comme
ncessaire. Laspiration est arrte.
La vanne double est rgle pour connecter le matriel au gaz dessai et laspiration est
commence. Les temps de rponse t(50) et t(90) sont pris comme intervalles de temps entre
le dbut de laspiration et le moment o le matriel atteint 50 % ou 90 %, respectivement, de
lindication finale.
Il convient dapporter une correction au temps de rponse pour permettre laspiration du
volume mort entre A et B dans la Figure B.1.

B.2.1

Matriel chantillonnant par diffusion


Mthode du masque de calibration

De lair propre est fourni au matriel, au dbit linaire recommand par le constructeur mais
ne dpassant pas 1 m/s, laide du masque (voir 5.2.3 et 5.3.4) jusqu ce que le matriel
soit stabilis. Le zro du matriel est rgl comme ncessaire. Le gaz dessai est ensuite
appliqu via une vanne double. Les temps de rponse t(50) et t(90) sont pris comme
intervalles de temps entre le dbut de laspiration et le moment o le matriel atteint 50 % ou
90 %, respectivement, de lindication finale.
Si la taille du masque est telle que le temps ncessaire pour le purger avec du gaz (avec le
matriel en position) dpasse 25 % du temps de rponse du matriel, cette mthode dessai
nest pas acceptable et une mthode alternative doit tre utilise.
Il est essentiel de corriger le temps de rponse pour permettre le volume mort entre le robinet
double et lentre du masque.
B.2.2

Mthode de lapplicateur (voir aussi les Figures B.2 et B.4)

Le matriel est mis en marche et stabilis.


Lalimentation dair propre est applique au matriel via un applicateur, par exemple tel que
montr dans la Figure B.2. Lapplicateur est tenu en position jusqu stabilisation du matriel.
Le zro du matriel est rgl comme ncessaire.

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

B.2

60079-29-1 CEI:2007

93

Le gaz dessai est appliqu au matriel via un second applicateur identique par
mouvement de substitution, par exemple comme montr la Figure B.3. Les temps
rponse t(50) et t(90) sont pris comme intervalles de temps entre le dbut de lessai
lapplicateur de gaz et le moment o le matriel atteint 50 % ou 90 %, respectivement,
lindication finale.

un
de
de
de

NOTE 1 La base de lapplicateur est en contact avec le matriel et entoure compltement lentre du capteur. La
surface de la base est au moins deux fois la surface de lentre du capteur.
NOTE 2

Le dbit linaire dair propre/gaz dessai la base des applicateurs est 50 mm/s 5 mm/s.

NOTE 3 Les espaces la base de lapplicateur sont suffisants pour viter une surpression dans lapplicateur de
plus de 50 Pa (qui correspond approximativement une pression de 5 mm deau) avec lapplicateur affleurant le
matriel ou le capteur comme montr la Figure B.3.
NOTE 4 La distance entre lpaulement de lapplicateur et lentre du capteur est typiquement de 10 fois le
diamtre de lapplicateur, par exemple comme montr la Figure B.4.
NOTE 5 Il est envisag quune gamme dapplicateurs, base sur les paramtres ci-dessus, soit exige pour
prouver la gamme complte de matriel ou de capteurs.

B.2.3

Mthode de la chambre dessai

B.2.3.1

Chambre dessai

La construction de la chambre peut englober une large varit de conception depuis des
installations sophistiques permanentes une simple enveloppe spcialement construite qui,
de lavis du laboratoire dessai, est capable dintroduire les gaz ou les capteurs de faon
rapide et reproductible.
Un exemple de chambre dessai est illustr la Figure B.5.
B.2.3.2

Procdure

Les chambres dessai peuvent tre indiffremment utilises de deux faons:


a) la chambre est tout dabord remplie du gaz dessai normalis et le capteur est plong
rapidement dedans, ou
b) le matriel est mis dans la chambre avec lentre du capteur couverte, la chambre est
remplie avec le gaz dessai normalis, et lentre du capteur est rapidement dcouverte.

B.3

Rponse aux variations chelonnes (voir aussi Figure B.6)

Le matriel utilis pour cet essai est montr schmatiquement la Figure B.6 et fonctionne
comme suit:
a) la cuve infrieure (1) est remplie deau;
b) le ballon (2) est rempli de 100 % LII mlange gaz/air jusqu ce que lextrmit basse du
tube soit remplie (3);
c) le mlange gaz/air est entr de force dans la cuve infrieure jusqu pousser au maximum
le ballon dans le tube;
d) le ballon est gonfl compltement pour obturer la partie basse du tube;
e) le mlange gaz/air est pomp dans la cuve infrieure dplaant leau dans la cuve
suprieure (4);
f)

le capteur (5) est positionn dans le tube environ 5 cm au-dessus de lextrmit


suprieure du ballon et la sortie de linstrument est connecte un enregistreur;

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

94

60079-29-1 CEI:2007

g) le ballon est cass par insertion dune pointe dans le tube au point (6). Ceci entrane un
chappement immdiat de mlange gaz/air du ballon et dun volume de 0,1 m 3 dans la
cuve infrieure qui est une pression denviron 7 kPa. Ceci purge immdiatement le tube
et alors que leau revient dans la cuve infrieure (en environ 20 s), le tube est aliment
par un flux continu de mlange frais scoulant une vitesse de environ 20 m/s. La
dure du flux peut tre allonge 30 s (temps maximal dessai), si ncessaire, en plaant
une restriction dans le raccord (7) entre les deux cuves. Un enregistreur, connect la
sortie de linstrument, fournira les temps intervalle de 1 s et ceci pourra tre utilis pour
dterminer le temps exig pour atteindre les lectures 50 % LII et 90 % LII. En varainte, le
ballon dans le tube de diamtre de 75 mm peut tre remplac par une vanne balle de 75
mm (taille type). Cela simplifie la procdure considrablement et le mme rsultat a t
obtenu aussi bien par louverture rapide de la vanne balle que par lclatement du
ballon.

B.4

Arrosage (voir aussi la Figure B.6)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Cet essai est ralis de la mme faon que lessai de rponse aux variations de lArticle B.3,
sauf quon utilisera le gaz dessai pour remplir le ballon et la cuve infrieure, au lieu du
mlange gaz/air.

Conteneurs de
gaz lastiques

Gaz dessai

Air propre

A
Vanne
double
C
Joint

B
Buse dentre du matriel
ou entre de la sonde
IEC 1295/07

NOTE 1 Le volume de chaque rservoir de gaz est plus important (par au moins un facteur de 10) que le volume
du gaz expuls pendant une dtermination du temps de rponse.
NOTE 2 Le calibre des tubes et connexions est plus important que le calibre de la buse dentre du matriel ou
lentre de la sonde.
NOTE 3 Le volume entre la vanne et lentre du matriel (entre B et C) est gard un minimum compatible avec
une bonne connexion au matriel.

Figure B.1 Exemple schmatique dquipement pour utilisation


avec du matriel aspiration
(voir aussi lArticle B.1)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

95

Air propre ou
gaz dessai

Dispositif de
mesure du dbit
Tube
flexible
Applicateur
tubulaire

Entre du
capteur

Matriel
ou capteur
IEC 1296/07

Figure B.2 Exemple schmatique dquipement pendant


lapplication dair propre ou de gaz dessai
(voir aussi B.2.2)

Dispositif de
mesure du dbit

Dispositif de
mesure du dbit

Tube
flexible

Gaz dessai

Air propre

Applicateur tubulaire
identique

Matriel
ou capteur
Entre du
capteur
Evacuation

IEC 1297/07

Figure B.3 Exemple schmatique dquipement montrant un changement de lair


propre au gaz dessai pour dbuter les mesures du temps de rponse (les flches
indiquent le mouvement des applicateurs)
(voir aussi B.2.2)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

96

60079-29-1 CEI:2007

Diffuseur/dflecteur
de gaz
Epaulement
dapplicateur

Applicateur
tubulaire

Dbit dair
propre/gaz
dessai
10 d

Espace

Matriel
ou capteur

Entre du
capteur
IEC 1298/07

Figure B.4 Exemple schmatique dentre dapplicateur ou de capteur pendant


lapplication de gaz dessai ou dair propre
(voir aussi B.2.2)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

97

Infra-rouge

Niveau dalarme

Vanne de scurit
Vanne de gaz
Concentration de gaz
dans lenregistreur de
la chambre dessai

Ventilation excdant dair


Dispositif chauffant

Tubes damortissement

Indicateur
dalarme

Ventilateur/
mlangeur
1

Isolation thermique
Arrive de rfrigrant
Bulbe
dchantillonnage
Systme
damortissement
Systme de schage

Enregistreur
de signaux
de dtection

3
2

1
2

4
5

Signal lumineux
Rfrigrant
IEC 1299/07

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Figure B.5 Exemple de chambre dessai automatique


(voir aussi B.2.3.1)

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

98

60079-29-1 CEI:2007
Tube en plastique clair
(diamtre 75 longueur 450)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Capteur

Eau
Ballon (jouet)

0 40 kPa psi
Manomtre

Ouverture
pour broche
Gaz
Entre

Conteneur
20 litres
Approx.
750

Cuve tanche au gaz


(diamtre 380 hauteur 350)
Tuyau

Eau
IEC 1300/07

Dimensions en millimetres

Figure B.6 Matriel pour essais de rponse aux variations et essai darrosage

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

60079-29-1 CEI:2007

99

Bibliographie
CEI 60050(351):1975, Vocabulaire lectrotechnique international (VEI) Chapitre 351:
Commande et rgulation automatiques
CEI 60050(426):1990, Vocabulaire lectrotechnique international (VEI) Chapitre 426 :
Matriels lectriques pour atmosphres explosives
CEI 60068-2-6:1995, Essais denvironnement Partie 2: Essais Essai Fc: Vibrations
(sinusodales)
CEI 60079-1: Atmosphres explosives Part 1: Protection du matriel par enveloppe
antidflagrante d
CEI 60079-2: Atmosphres explosives Partie 2: Protection du matriel par enveloppe
surpression interne "p"
CEI 60079-5: Atmosphres explosives Partie 5: Protection du matriel par remplissage
pulvrulent q
CEI 60079-6: Atmosphres explosives Partie 6: Protection du matriel par immersion dans
lhuile "o"
CEI 60079-7: Atmosphres explosives Partie 7: Protection du matriel par scurit
augmente "e"
CEI 60079-10: Matriels lectriques pour atmosphres explosives gazeuses Partie 10:
Classement des emplacements dangereux
CEI 60079-11: Atmosphres explosives Partie 11: Protection de lquipement par scurit
intrinsque i
CEI 60079-15: Matriels lectriques pour atmosphres explosives gazeuses Partie 15:
Construction, essais et marquage des matriels lectriques du mode de protection n
CEI 60079-18: Matriels lectriques pour atmosphres explosives gazeuses Partie 18:
Construction, essais et marquage des matriels lectriques du type de protection par
encapsulage "m"
CEI 60079-25: Matriels lectriques pour atmosphres explosives gazeuses Partie 25:
Systmes de scurit intrinsque
CEI 60079-26: Atmosphres explosives Partie 26: Matriel dun niveau de protection du
matriel (EPL) Ga
ISO 2738: Matriaux mtalliques fritts permables Dtermination de la masse volumique,
de la teneur en huile et de la porosit ouverte
ISO 4003: Matriaux en mtal fritt permable Dtermination de la dimension des pores
Mthode bulloscopique
ISO 4022: Matriaux mtalliques fritts permables Dtermination de la permabilit aux
fluides
ISO 6142: Analyse des gaz Prparation des mlanges de gaz pour talonnage Mthode
gravimtrique (disponible en anglais seulement)
ISO 6145-1: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 1: Mthodes d'talonnage (disponible en
anglais seulement)

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

100

60079-29-1 CEI:2007

ISO 6145-2: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 2: Pompes volumtriques
ISO 6145-4: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 4: Mthode continue par seringue dinjection
ISO 6145-5: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 5: Dispositifs d'talonnage par capillaires
ISO 6145-6: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 6: Orifices critiques (disponible en anglais
seulement)
ISO 6145-7: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 7: Rgulateurs thermiques de dbit-masse
ISO 6145-9: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide de
mthodes volumtriques dynamiques Partie 9: Mthode par saturation
ISO 6145-10: Analyse des gaz Prparation des mlanges de gaz pour talonnage l'aide
de mthodes volumtriques dynamiques Partie 10: Mthode par permation

___________

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
3, rue de Varemb
P.O. Box 131
CH-1211 Geneva 20
Switzerland
Tel: + 41 22 919 02 11
Fax: + 41 22 919 03 00
info@iec.ch
www.iec.ch

--```,,,,,,````,```,`,`,`,`,`,`-`-`,,`,,`,`,,`---

Copyright International Electrotechnical Commission


Provided by IHS under license with IEC
No reproduction or networking permitted without license from IHS

Licensee=Malaysia /5940240045
Not for Resale, 10/17/2012 05:18:28 MDT

You might also like