Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Westen Con Dens Range

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

The smart choice for your home comfort

Highest efciency, ma
maximum in comfort and easiest in use

The smart choice for your home comfort

Star Condens and Boyler Condens are part of Westen wall hung condensing range
(combi, heating only and with storage models) designed to offer all you can expect
from a condensing boiler ensuring the highest efciency, the maximum in comfort and
the easiest in use.

Saving
Higher efciency means energy saving that
is gas expenditure remarkable cutback.
4 stars according to CE/92/42 (European
standard dening the boilers efciency)

Easiness of use
Westen made the Star Condens condensing
boilers easier in use thanks to the digital
display, the operational mode lights and
the regulation knobs

Low noise level


Westen provided Star Condens with a new
soundproong heat exchangers external
casing that makes these boilers quiet in
ignition and operation

Compact dimensions
Star Condens have been designed to allow
an easy tting anywhere: inside a cupboard
in case space saving represent an issue (only
760x450x345mm)

COMBI

HEATING ONLY

Star Condens 240 Star Condens 280 Star Condens 1.240


Maximum DHW heat input

kW

24,7

28,9

Maximum heating heat input

kW

20,5

24,7

24,7

Maximum DHW heat output

kW

24

28

Maximum heating heat output 80/60C

kW

20

24

24

Maximum heating heat output 50/30C

kW

21,6

25,9

25,9

Minimum heat output 80/60C

kW

6,8

8,7

6,8

Minimum heat output 50/30C

kW

7,4

9,5

++++

++++

Energetic efciency (92/42/CEE)

7,4
++++

Average efcency (DIN 4702-T8)

109,8

109,8

Nominal efciency 80/60C

97,6

97,6

97,6

Nominal efciency 50/30C

105,1

105

105,1

Efciency at 30%

107,5

107,5

107,5

-5

-5

-5

NOx class (EN 483)


Minimum working temperature
Expansion vessel capacity/pre-charge

109,8

l/bar

8/0,5

8/0,5

8/0,5

25/80

25/80

25/80

Domestic hot water temperature range

35/60

35/60

Continuous DHW production 6T 25C

l/min

13,8

16,1

Maximum pressure on heating circuit

bar

Maximum pressure DHW circuit

bar

Coaxial ue system 60/100 max length

10

10

10

Heating temperature range

Dual ue system 80 max length

80

80

80

Maximum ue mass ow rate

kg/s

0,012

0,014

0,012

Minimum ue mass ow rate

0,003

kg/s

0,003

0,004

Maximum ue temperature

73

75

73

Dimensions (h x l x p)

mm

760x450x345

760x450x345

760x450x345

Net weight

kg

Gas type
Power consumption
Grade of protection

44

45

45

Natural gas/LPG

Natural gas/LPG

Natural gas/LPG

150

155

150

IPX5D

IPX5D

IPX5D

>
>
>
>
>
>
>
>
>
>
>
>

Stainless steel heat exchanger


Pre-mixing group including modulating fan
Electric 3 way valve for all models
Enhanced stainless steel domestic hot water
heat exchanger (combi models)
Automatic by-pass
Circulating pump with built-in air vent
Built-in climatic regulation (outdoor sensor as
optional)
Remote control available as optional
User friendly control panel/digital display
System to prevent pump and 3 way valve
sticking operating every 24 hours
Full anti-frost device
Central heating safety valve set at 3 bar

TEMPERATURE REGULATION ACCESSORIES*

REMOTE CONTROL
- automatic processing of the heating ow
water temperature
- room thermostat and timer
- self-check: detection and description up
to 13 anomalies
- display and regulation of boilers
parameters, like room temperature and
external temperature, DHW and
central heating water temperature
- connection to the boiler through an
interface card (only combi and heating
only models)
*as optional

Boyler Condens is the new Westen condensing storage boiler, that combines very high
technology with peerless sanitary performances.

Saving
Higher efciency means energy saving that
is gas expenditure remarkable cutback.
4 stars according to CE/92/42 (European
standard dening the boilers efciency)

Exchanger
Stainless steel heat exchanger which ensures
reliability and long life

Advance electronics
Boyler Condens is provided with a digital
control panel with push buttons and wide
LCD display with text and symbols

High sanitary performances


Westen has provided Boyler Condens with
a 45 lt cylinder which grants a domestic
hot water production up to 385 lt in 30 (6T
30C). The cylinder takes only 5 to recover
the set temperature.
>
>
>
>
>
>
>
>
>
>

45 lt stainless steel AISI 316L cylinder


Pre-mixing group including modulating fan
Electric 3 way valve
Automatic by-pass
Circulating pump with built-in air vent
Anti-legionella system
Multifunction display
Built-in climatic regulation (outdoor sensor as optional)
Remote control available as optional
System to prevent pump and 3 way valve
sticking operating every 24 hours
> Full anti-frost device
> Central heating safety valve set at 3 bar
> Cylinder safety valve set at 8 bar

Boyler Condens 240


Maximum DHW heat input

kW

24,7

Maximum heating heat input

kW

24,7

Maximum DHW heat output

kW

24

Maximum heating heat output 80/60C

kW

24

Maximum heating heat output 50/30C

kW

25,9

Minimum heat output 80/60C

kW

Minimum heat output 50/30C

kW

6,5

Average efcency (DIN 4702-T8)

Nominal efciency 80/60C

97,6

Nominal efciency 50/30C

105,1

Efciency at 30%

107,5

-5

l/bar

7,5/0,5

NOx class (EN 483)


Minimum working temperature
Expansion vessel capacity/pre-charge

Westen recommends the use of temperature


regulation accessories to have the highest efciency,
the maximum comfort and the easiest in use.

OUTDOOR SENSOR
- adjustment of the central heating water
temperature according to the real outdoor temperature
- the central heating water temperature is
the minimum necessary assuring the
maximum condensation
- quick reaction to sudden change of weather
- less heat losses in the piping thanks to a
lower temperature

++++

Energetic efciency (92/42/CEE)

109,8

Heating temperature range

25/80

Domestic hot water temperature range

10/60

Continuous DHW production 6T 25C

l/min

13,8

DHW production at 6T 30C

l/30

385

Maximum pressure on heating circuit

bar

Maximum pressure DHW circuit

bar

Coaxial ue system 60/100 max length

10

Dual ue system 80 max length

80

Maximum ue mass ow rate

kg/s

0,012

Minimum ue mass ow rate

kg/s

0,003

Maximum ue temperature

73

Dimensions (h x l x p)

mm

950x600x466

Net weight

kg

Gas type
Power consumption
Grade of protection

66
Natural gas/LPG

150
IPX5D

F L U E AC C E S S O R I E S
C OA X I A L F L U E S Y S T E M
1

COAXIAL FLUE TUBES WITH TERMINAL


Length: 750 mm
with proof terminal
sealing collar.
KHG714059613 .

COAXIAL 90 BEND
KHG714059717 .

VERTICAL CHIMNEY TERMINAL


80/125
KHG714093510 .

REDUCTION TO 60/100
KHG714093910 .

PITCHED ROOF TILE


To be used with a vertical chimney terminal.
It is adjustable from 15 to 45.
KHG714093710 .

COAXIAL FLUE TUBES EXTENSION


Length: 1000 mm
KHG714059514 .

COAXIAL 45 BEND
KHG714059817 .

FLAT ROOF TILE


To be used with a vertical chimney terminal.
KHG714093610 .

INTERNAL SEALING COLLAR 100


KHG714017710 .

1
6
2

7
4

8
5
9

DUAL FLUE SYSTEM


It includes:
ue reduction
intake connection.
KHG714059113 .

TUBE 80
L = 1000 KHG714059411 .
L = 500 KHG714059910 .

90/45 BEND 80 AND 60


90 80 KHG714059211 .
45 80 KHG714059311 .

EXTERNAL SEALING COLLAR 80


KHG714018411 .

INTERNAL SEALING COLLAR 80


KHG714018510 .

DUAL FLUE VERTICAL


CHIMNEY TERMINAL
For dual system single
outlet on the roof.
KHG714093810 . (adapter)
KHG714093510 .

DUAL FLUE TERMINAL 80


KHG714010410 .

4
5

www.westen.eu

WESTEN - Via Trozzetti, 20 - 36061 BASSANO DEL GRAPPA - ITALY - T +39 0424 517111 - F +39 0424 38089 - 03/12

DUAL FLUE SYSTEM

The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice.

You might also like