Alim 48Vcc 20A
Alim 48Vcc 20A
com/us/products/2866695
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking)
Technology, input: 1-phase, output: 48 V DC/20 A
Product Description
QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system
protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states
before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V
DC ... 56 V DC are covered.
1 STK
GTIN
GTIN
4046356547727
3,820.000 g
85044030
Country of origin
Thailand
Technical data
Dimensions
Width
180 mm
12/06/2016Page1/9
https://www.phoenixcontact.com/us/products/2866695
130 mm
Depth
125 mm
122 mm
130 mm
183 mm
Ambient conditions
Degree of protection
IP20
-40 C ... 85 C
95 % (at 25 C, non-condensing)
Noise immunity
EN 61000-6-2:2005
Maximum altitude
6000 m
Input data
Nominal input voltage range
85 V AC ... 264 V AC
90 V DC ... 300 V DC (UL 508: 250 V DC)
300 V AC
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Discharge current to PE
< 3.5 mA
Current consumption
< 15 A (typical)
Input fuse
Type of protection
Protective circuit/component
Varistor
Output data
Nominal output voltage
48 V DC 1%
https://www.phoenixcontact.com/us/products/2866695
Derating
60 C ... 70 C (2.5%/K)
Connection in parallel
Connection in series
yes
Control deviation
Residual ripple
Output power
960 W
< 0.65 s
12 W
74 W
General
Net weight
3.3 kg
Efficiency
4 kV AC (type test)
2 kV AC (routine test)
Protection class
Mounting position
Assembly instructions
Screw connection
0.2 mm
6 mm
0.2 mm
4 mm
14
10
Stripping length
7 mm
Screw thread
M3
https://www.phoenixcontact.com/us/products/2866695
Screw connection
0.5 mm
16 mm
0.5 mm
16 mm
Stripping length
10 mm
Screw thread
M3
0.2 mm
6 mm
0.2 mm
4 mm
24
10
Screw thread
M3
Shock
Noise emission
Noise immunity
EN 61000-6-2:2005
CSA
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN61000-4-6
EN 50178
EN 61000-3-2
BG (design tested)
12/06/2016Page4/9
https://www.phoenixcontact.com/us/products/2866695
UL approvals
UL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous
Location)
Vibration (operation)
Rail applications
EN 50121-4
III
nd
Drawings
Block diagram
L (+)
active
N (-)
PFC
DC OK
I < IN
13
14
Classifications
eCl@ss
eCl@ss 4.0
27040702
eCl@ss 4.1
27040702
eCl@ss 5.0
27242213
eCl@ss 5.1
27242213
eCl@ss 6.0
27049002
eCl@ss 7.0
27049002
eCl@ss 8.0
27049002
eCl@ss 9.0
27040701
ETIM
ETIM 3.0
EC001039
ETIM 4.0
EC002540
ETIM 5.0
EC002540
12/06/2016Page5/9
https://www.phoenixcontact.com/us/products/2866695
EC002540
UNSPSC
UNSPSC 6.01
30211502
UNSPSC 7.0901
39121004
UNSPSC 11
39121004
UNSPSC 12.01
39121004
UNSPSC 13.2
39121004
Approvals
Approvals
Approvals
CSA / UL Recognized / UL Listed / IECEE CB Scheme / EAC / EAC / DNV GL
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services/testingand-certification/certified-product-listing/
2448618
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 211944
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 123528
IECEE CB Scheme
http://www.iecee.org/
SI-2748
12/06/2016Page6/9
https://www.phoenixcontact.com/us/products/2866695
EAC-Zulassung
EAC
7500651.22.01.00242
DNV GL
https://www.dnvgl.com/
TAE000014W
Accessories
Accessories
Assembly adapter
Assembly adapters-UWA 182/52-2938235
Universal wall adapter for securely mounting the power supply in the event of strong vibrations. The power supply is
screwed directly onto the mounting surface. The universal wall adapter is attached at the top/bottom.
Redundancy module
12/06/2016Page7/9
https://www.phoenixcontact.com/us/products/2866695
DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
12/06/2016Page8/9
https://www.phoenixcontact.com/us/products/2866695
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
12/06/2016Page9/9