Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ATA 35 Oxygen PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

A380

TECHNICAL TRAINING MANUAL


RAMP & SERVICING COURSE - M02 (RR Trent 900)
ATA 35 Oxygen

This document must be used for training purposes only

Under no circumstances should this document be used as a reference

It will not be updated.

All rights reserved


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.

AIRBUS Environmental Recommendation


Please consider your environmental responsability before printing this document.

A380 TECHNICAL TRAINING MANUAL

ATA 35 OXYGEN

LAY08521 - L1502T0

Oxygen System Presentation (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

RAMP & SERVICING COURSE - M02 (RR Trent 900)


ATA 35 Oxygen

TABLE OF CONTENTS

Jan 13, 2009


Page 1

A380 TECHNICAL TRAINING MANUAL

OXYGEN SYSTEM PRESENTATION (1)


General

LAY08521 - L1502T0 - LM35P4000000001

The Oxygen is supplied to the crew and cabin passengers in case of


sudden cabin depressurization.
In addition, the oxygen is supplied to the crew members in case of smoke
or dangerous gases in the cockpit.

RAMP & SERVICING COURSE - M02 (RR Trent 900)


ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 2

LAY08521 - L1502T0 - LM35P4000000001

A380 TECHNICAL TRAINING MANUAL

GENERAL
RAMP & SERVICING COURSE - M02 (RR Trent 900)
ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 3

A380 TECHNICAL TRAINING MANUAL

OXYGEN SYSTEM PRESENTATION (1)


Flight Crew Oxygen System
The flight crew oxygen system has three sections:
The oxygen storage,
The oxygen distribution and
The oxygen control and indicating.

Storage
The flight crew oxygen is stored in a high-pressure oxygen cylinder.
This cylinder is located in the upper avionics compartment and placed
in a cradle.
Optionally the flight crew oxygen system can carry up to four
cylinders.

Distribution

LAY08521 - L1502T0 - LM35P4000000001

The oxygen supplies the flight crew stations through a distribution


circuit. High pressure is reduced to low pressure by the pressure
reducer/transmitter.
Low pressure oxygen flows via the low pressure supply valve to the
distribution manifold. Then, the manifold supplies the oxygen to the
mask stowage boxes in the cockpit.
Each mask stowage box has a full face quick donning mask.

Control and Indicating


A pushbutton switch, located on the overhead panel, controls the low
pressure supply valve.
The status of the flight crew oxygen system (oxygen supply pressure,
oxygen pressure in the cylinder, high pressure or low pressure
warnings) is indicated on the DOOR/OXY page of the ECAM system
display (SD).

RAMP & SERVICING COURSE - M02 (RR Trent 900)


ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 4

LAY08521 - L1502T0 - LM35P4000000001

A380 TECHNICAL TRAINING MANUAL

FLIGHT CREW OXYGEN SYSTEM - STORAGE ... CONTROL AND INDICATING


RAMP & SERVICING COURSE - M02 (RR Trent 900)
ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 5

A380 TECHNICAL TRAINING MANUAL

OXYGEN SYSTEM PRESENTATION (1)


Passenger Oxygen System
The passenger oxygen system has three sections:
The oxygen storage,
The oxygen distribution and
The oxygen control and indicating.

Storage
The oxygen cylinders are installed on the right hand side of the forward
cargo compartment.
The standard configuration includes three cylinders and up to fifteen
cylinders as an option.

Distribution
The oxygen supplies the passenger masks through a distribution circuit.
High pressure is reduced to low pressure by the pressure
reducer/transmitters. Low-pressure oxygen flows via the oxygen
regulator to the distribution lines connected to the masks.

LAY08521 - L1502T0 - LM35P4000000001

Control and Indicating


The system can be automatically activated when the cabin altitude
exceeds 14000ft, by the Cabin Pressure Control System (CPCS)
(application hosted in CPIOM-Bs) through the Oxygen System Control
Unit (OSCU), or directly by the altitude pressure switch as a back up.
It can also be manually activated on crew action. The "SYS ON"
indicator light comes on in both cases.
A manual release tool triggers the oxygen container opening.
The status of the passenger oxygen system (oxygen supply, oxygen
pressure, high pressure or low pressure warnings) is indicated on the
DOOR/OXY page of the ECAM System Display.

RAMP & SERVICING COURSE - M02 (RR Trent 900)


ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 6

LAY08521 - L1502T0 - LM35P4000000001

A380 TECHNICAL TRAINING MANUAL

PASSENGER OXYGEN SYSTEM - STORAGE ... CONTROL AND INDICATING


RAMP & SERVICING COURSE - M02 (RR Trent 900)
ATA 35 Oxygen

OXYGEN SYSTEM PRESENTATION (1)

Jan 13, 2009


Page 7

AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE LAY08521
JANUARY 2009
PRINTED IN FRANCE
AIRBUS S.A.S. 2009
ALL RIGHTS RESERVED
AN EADS COMPANY