Water Distribution: Pipelines
Water Distribution: Pipelines
Water Distribution: Pipelines
A water distribution system is a network of pumps, pipelines, storage tanks, and other
appurtenances. It must deliver adequate quantities of water at pressures sufficient for operating
plumbing fixtures and firefighting equipment, yet it must not deliver water at pressures high enough
to increase the occurrence of leaks and pipeline breaks. Pressure-regulating valves may be installed
to reduce pressure levels in low-lying service areas. More than half the cost of a municipal water
supply system is for the distribution network.
Pipelines
The pipeline system of a municipal water distribution network consists of arterial water mains or primary
feeders, which convey water from the treatment plant to areas of major water use in the community, and
smaller-diameter pipelines called secondary feeders, which tie in to the mains. Usually not less than 150 mm (6
inches) in diameter, these pipelines are placed within the public right-of-way so that service connections can be
made for all potential water users. The pipelines are usually arranged in a gridiron pattern that allows water to
circulate in interconnected loops; this permits any broken sections of pipe to be isolated for repair without
disrupting service to large areas of the community. Dead-end patterns may also be used, but they do not
permit circulation, and the water they provide is more susceptible to taste and odour problems because of
stagnation.
A water distribution pipeline must be able to resist internal and external forces, as well as corrosion. Pipes are
placed under stress by internal water pressure, by the weight of the overlying soil, and by vehicles passing
above. They may have to withstand water-hammer forces; these occur when valves are closed too rapidly,
causing pressure waves to surge through the system. In addition, metal pipes may rust internally if the water
supply is corrosive or externally because of corrosive soil conditions.
MATERIALS
Distribution pipes are made of asbestos cement, cast iron, ductile iron, plastic, reinforced concrete, orsteel.
Although not as strong as iron, asbestos cement, because of its corrosion resistance and ease of installation, is a
desirable material for secondary feeders up to 41 cm (16 inches) in diameter. Pipe sections are easily joined
with a coupling sleeve and rubber-ring gasket. Cast iron has an excellent record of service, with many
installations still functioning after 100 years. Ductile iron, a stronger and more elastic type of cast iron, is used
in newer installations. Iron pipes are provided in diameters up to 122 cm (48 inches) and are usually coated to
prevent corrosion. Underground sections are connected with bell-and-spigot joints, the spigot end of one pipe
section being pushed into the bell end of an adjacent section. A rubber-ring gasket in the bell end is
compressed when the two sections are joined, creating a watertight, flexible connection. Flanged and bolted
joints are used for aboveground installations.
PEOPLE
TOPICS
Archimedes
Benjamin Latrobe
Indravarman I
Plastic pipes are available in diameters up to 61 cm (24 inches). They are lightweight, easily installed, and
corrosion-resistant, and their smoothness provides good hydraulic characteristics. Plastic pipes are connected
either by a bell-and-spigot compression-type joint or by threaded screw couplings.
Precast reinforced concrete pipe sections up to 366 cm (12 feet) in diameter are used for arterial mains.
Reinforced concrete pipes are strong and durable. They are joined using a bell-and-spigot-type connection that
is sealed with cement mortar. Steel pipe is sometimes used for arterial mains in aboveground installations. It is
very strong and lighter than concrete pipe, but it must be protected against corrosion with lining of the interior
and with painting and wrapping of the exterior. Sections of steel pipe are joined by welding or with mechanical
coupling devices.
FITTINGS
In order to function properly, a water distribution system requires several types of fittings, including hydrants,
shutoff valves, and other appurtenances. The main purpose of hydrants is to provide water for firefighting.
They also are used for flushing water mains, pressure testing, water sampling, and washing debris off public
streets.
Many types of valves are used to control the quantity and direction of water flow. Gate valves are usually
installed throughout the pipe network. They allow sections to be shut off and isolated during the repair of
broken mains, pumps, or hydrants. A type of valve commonly used for throttling and controlling the rate of
flow is the butterfly valve. Other valves used in water distribution systems include pressure-reducing valves,
check valves, and air-release valves.
INSTALLATION
Water mains must be placed roughly 1 to 2 metres (3 to 6 feet) below the ground surface in order to protect
against traffic loads and to prevent freezing. Since the water in a distribution system is under pressure,
pipelines can follow the shape of the land, uphill as well as downhill. They must be installed with proper
bedding and backfill. Compaction of soil layers under the pipe (bedding) as well as above the pipe (backfill) is
necessary to provide proper support. A water main should never be installed in the same trench with a sewer
line. Where the two must cross, the water main should be placed above the sewer line.
Pumps
Many kinds of pumps are used in distribution systems. Pumps that lift surface water and move it to a nearby
treatment plant are called low-lift pumps. These move large volumes of water at relatively low discharge
pressures. Pumps that discharge treated water into arterial mains are called high-lift pumps. These operate
under higher pressures. Pumps that increase the pressure within the distribution system or raise water into an
elevated storage tank are called booster pumps. Well pumps lift water from underground and discharge it
directly into a distribution system.
IMAGES
Most water distribution pumps are of the centrifugal type, in which a rapidly rotating impeller adds energy to
the water and raises the pressure inside the pump casing. The flow rate through a centrifugal pump depends on
the pressure against which it operates. The higher the pressure, the lower the flow or discharge. Another kind
of pump is the positive-displacement type. This pump delivers a fixed quantity of water with each cycle of a
piston or rotor. The water is literally pushed or displaced from the pump casing. The flow capacity of a
positive-displacement pump is unaffected by the pressure of the system in which it operates.
Storage tanks
Distribution storage tanks, familiar sights in many communities, serve two basic purposes: equalizing storage
and emergency storage. Equalizing storage is the volume of water needed to satisfy peak hourly demands in
the community. During the late night and very early morning hours, when water demand is lower, high-lift
pumps fill the tank. During the day, when water demand is higher, water flows out of the tank to help satisfy
the peak hourly water needs. This allows for a uniform flow rate at the treatment plant and pumping station.
Water in a distribution storage tank may also be needed for fighting fires, cleaning up accidental spills of
hazardous materials, or other community emergencies. The capacity of a distribution storage tank is designed
to be about equal to the average daily water demand of the community.
Distribution storage tanks are built at ground level on hilltops higher than the service area. In areas with flat
topography, the tanks may be elevated aboveground on towers in order to provide adequate water pressures, or
ground-level storage tanks with booster pumping may be provided.