Single Pole Humidity Sensor and Fan Controller: Installation Instructions
Single Pole Humidity Sensor and Fan Controller: Installation Instructions
Single Pole Humidity Sensor and Fan Controller: Installation Instructions
DI-000-IPHS5-02A
INSTALLATION INSTRUCTIONS
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, or a load in excess of the specified rating.
To be installed and/or used in accordance with electrical codes and regulations.
If you are not sure about any part of these instructions, consult an electrician.
Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning liquids.
No user serviceable components. DO NOT attempt to service or repair.
Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil Cutters Ruler
Step 1
DESCRIPTION
FEATURES
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
TO BACK WIRE:
Back wire openings
use #14-12 AWG
solid copper wire
only.
TO SIDE WIRE:
Side wire terminals
accept #14-12 AWG
solid and stranded
copper wire.
Wire
Wire
Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
S
trip conductors 3/4 (1.9 cm) for side wire
applications or 5/8
(1.6 cm) for back wire applications.
Cut
(if necessary)
Go to Step 4 for wiring instructions.
Your device may include color options. To change color of the face
proceed as follows:
3
4
Lo
T EST
R ESET
2
1
2
3
off
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Sensor
Terminal
Screw marked
Black (BK)
BK
Terminal Screw
Marked White (WH)
WH
2
1
3
4
1
2
Ground
(Green Screw)
3
4
Md
Hi
20
off
80
cycle
RD
Line
120 VAC, 60Hz
White
Neutral (White)
RD
TEST
RESE
Black
Single-Pole
Green
Ground
BK
Step 4 Installation:
Hot (Black)
BK
SENSOR:
Connect wires per WIRING DIAGRAM as follows:
LOCATION / MOUNTING
WH
WIRING
RD
YL 3-Way
Sensor
The IPHS5 is a humidity sensor and switch for control of bath fans and
combination bath fan/lights. The IPHS5 detects changes in humidity for
control of condensation in bathroom application or house ventilation. It
is compatible with bath fans rated at 1/6th HP and fan/light combinations
with single switched load.
Terminal
Screw marked
Red (RD)
DIAL SETTINGS
SENSOR DIALS
Sensitivity
Lo
Md
Hi
ff
Time
(20 min.)
(30 min.)
Humidistat
(Stop Mark)
20
80
ff
(10 min.)
MANUAL OPERATION
MODES OF OPERATION
With the power restored and the wallplate removed, remove the face
of the device to expose the setting controls (see Color Change Kit
removal on page 1). Use a small screwdriver to make adjustments to
the device as required for the application.
Time - factory default is 10 minutes (1)
1. A
djust the time selector to set the time out duration, which is the
minimum desired length of time the load/fan will remain ON after
being turned on in any mode of operation.
2. R
efer to Sensors Dials chart for available time period options.
3. F
or use with all three Automatic Modes of Operation.
Sensitivity - To reduce false activation, reduce sensitivity.
1. H
i - Default Setting.
2. M
edium
3. Low
4. O
FF - used in Air Cycle mode.
Humidistat factory default is OFF (off)
1. O
FF - device ignores the humidity set point and controls load/fan
based on detection of excess humidity.
2. M
inimum relative humidity set point may be set between 20% and
80% - sets the ambient humidity threshold below which the load/
fan must be operated manually and/or above which the load/fan will
be operated according to one of the automatic modes of operation.
3. Cycle - Only used in Air Cycle Mode.
cyc
le
(45 min.)
NOTE: DO NOT rotate the adjustment dials past the stop marks shown
in the figure above.
Status
Fan (load) OFF
Fan (load) ON
Air Cycle Mode is active
Manual override
At any time the device can be manually controlled with the push pad on the
front of the device just below the Locator Light.
1. Manual Operation in Auto ON/Auto OFF
Manual ON - When manually turned ON with the push pad in this
mode, and unless the device enters automatic operation by detecting
excess humidity thereafter, the device will time out and turn OFF based
on the time out setting. If the device has been manually turned on and
excess humidity is detected before the time out period has lapsed, the
device will override manual operation and assume control in automatic
mode, turning the load/fan OFF after the humidity level declines to an
acceptable level.
Manual OFF - At any time the push pad can be pressed to manually turn
the load/fan OFF.
2. Manual Operation in Auto ON/Auto OFF with humidity set points
Manual ON - When manually turned ON with the push pad in this mode,
and unless the device enters automatic operation by detecting excess
humidity above the humidity set point thereafter, the device will time
out and turn OFF based on the time out setting. If the device has been
manually turned on and excess humidity is detected above the humidity
set point before the time out period has lapsed, the device will override
manual operation and assume control in automatic mode, turning the
load/fan OFF after the humidity level declines to an acceptable level.
Manual OFF - At any time the push pad can be pressed to manually turn
the load/fan OFF.
3. Manual Operation in Air Cycle Mode
Manual ON - When manually turned ON with the push pad in this mode,
setting the initial ON time, the device will time out and turn OFF based on
the time out setting and continue to cycle ON every hour until it is shut
OFF.
Manual OFF - Pressing the push pad when the load/fan is ON will
disable the Air Cycle Mode until the load/fan is manually turned back ON.
TROUBLESHOOTING
Load/fan does not turn ON in the presence of humidity (e.g. after a
shower):
If the sensor is installed in a high humidity area it may be necessary
to adjust the humidistat settings.
Load/fan turns ON throughout the day:
C
hange sensor's mode of operation to desired setting.
Load/fan turns ON and OFF during a shower:
T
his is normal operation for rooms with good ventilation.
NOTE: DO NOT use to control a fan/light combination where this is the
only means of illumination.
NOTE: The Leviton humidity sensor and fan control will not eliminate
condensation and must be used with a properly sized ventilation fan in
an enclosed space.
For additional information, contact Levitons Techline at
1-800-824-3005 or visit Levitons website at www.leviton.com
FCC CAUTION
Step 7
Dials
Humidistat
Sensitivity
Time
OFF
Any
Between 20 and 80
Any
Air Cycle
Cycle
OFF
Any
DI-000-IPHS5-02A