MTO210

Transformer Ohmmeter

MTO210
Transformer Ohmmeter
n Direct 2-channel digital reading
(1 mW to 2000 W)
n DC test current up to 10 A maximum
n 0.25% measurement accuracy
n Integrated demagnetization feature
n Tests operation of on-load tap-changers
n Very fast auto safety discharge circuit

DESCRIPTION A regular maintenance program that includes winding


The MTO210 Transformer Ohmmeter is a line-operated, resistance measurements is the most effective way to
field-portable instrument designed specifically to measure use this instrument. Once a benchmark is established,
the dc resistance of all types of magnetic windings safely subsequent test results can be compared to determine if
and accurately. It can test transformers and rotating changes are occurring in the transformers and associated
machine windings and perform low-current resistance control wiring, voltage regulators, motors, generators,
measurements on connections, contacts and control circuits. breaker contacts, and all types of connections (bolted,
soldered, crimped, etc.).
The dual set of potential inputs measures the resistance
of the primary and secondary windings of a single- or Tap-changers are mechanical devices and the most
three-phase transformer simultaneously. This dual reading, vulnerable part of a transformer. Tap-changers result in
dual injection characteristic, also helps to speed up the more failures and outages than any other component and
measurements when used to test LV windings on large so require frequent testing and attention to ensure reliable
three-phase power transformers. and safe operation.
The Transformer Ohmmeter is extremely useful when FEATURES AND BENEFITS
testing the windings and contact resistance of tap-changers n Direct 2-channel digital reading allows for testing two
with make-before-break contacts and voltage regulators. windings at a time.
This action will check for pitted or misaligned contacts as n Very fast discharge time.
the instrument will give an indication if either condition
n High-contrast, large alphanumeric displays can be seen
occurs.
in bright sunlight.
Users are also protected by the auto-shutdown safety n User-selectable maximum current range ensures
feature. Any inadvertent disconnection of a test lead or loss protection of small transformers.
of power to the instrument will safely discharge the energy
n Beacon drive circuit is provided for use with optional
stored in the unit under test (UUT).
beacon strobe light.
APPLICATIONS n Built-in demagnetization circuitry allows the operator

The MTO210 Transformer Ohmmeter is used: to de-magnetize the transformer core upon completion
n To verify factory test readings. of resistance testing, or as a stand-alone feature before
n As part of a regular maintenance program.
SFRA testing or when the transformer is put back in
service.
n To help locate the presence of defects in transformers,
n The MTO210 allows for test of transformers with on-
such as loose connections.
load tap-changers and provides a break-before-make
n To check the make-before-break operation of on-load
indicator, in the event of any discontinuity.
tap-changers.
MTO210
Transformer Ohmmeter

n For those users who choose to create an external Output


interlock safety perimeter, a safety interlock circuit is User Selectable Current Ranges: up to 10 mA
provided. up to 100 mA
up to 1 A
n Remote trigger switch is also provided for testing
up to 10 A
transformers with tap-changers. Open-Circuit Test Voltage: up to 50 V dc
n Internal flash memory allows for mass storage of dataset
Resistance Measurement/Display
records, for later recall, printing, and analysis. Resistance: 1 mW to 2000 W
n Ruggedized clamps, with 4 inch (100 mm) jaws, are Accuracy: 0.25% reading, 0.25% full scale (when current has
provided eliminating the need for bushing adapters. stabilized)
Resolution: Up to 6 digits
n Kelvin clamps/cables (optional) for easy connection to

the transformer Displays


Two 1 high, 6 character, 7-segment, LCDs
n Compatible with PowerDB software package.
One 0.71 high, 6 character, 7-segment, LCD
n Built-in discharge circuit safely discharges the specimen
Printer
when test is completed, if lead accidentally disconnects, Via RS-232 port
or if power is lost. User Interface
n Output RS232 serial port is provided for optional printing B&W alphanumeric displays, keypad
of results and/or data analysis on a PC. Computer Interface (for downloading results)
n Detachable lid for ease of use. Via RS-232 port
n Unit can be operated while in transit case. Internal Data Storage
n Leads can stay connected while in transit case.
Up to 10,000 data sets
Environmental
SPECIFICATIONS Operating: 14 F to 122 F (-10 C to 50 C)
Input Storage: 5 F to 158 F (-15 C to +70 C)
120/240 V, 50/60 Hz, 720 VA Relative Humidity: 0-90% non-condensing
Dimensions
8.5 H x 21.5 W x 13 D in (216 H x 546 W x 330 D mm)
Weight
Net 29 lb (13.1 kg)

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
Transformer Ohmmeter Optional Accessories
120/240 volt, 50/60 Hz input MTO210
V1 Potential Lead Set, 100 ft (30 m) 2001-403
Included Accessories V2 Potential Lead Set, 100 ft (30 m) 2001-404
V1 Potential Lead Set, 60 ft (18 m) 2000-700 Jumper Lead, 50 ft (15 m) 2001-405
V2 Potential Lead Set, 60 ft (18 m) 2000-701 Current Lead Set, 100 ft (30 m) 2001-406
Current Lead Set, 60 ft (18 m) 2000-702 Kelvin Lead Set, 60 ft (18 m) 2001-407
Jumper Lead, 30 ft (9 m) 2000-703 Kelvin Lead Set, 100 ft (30 m) 2001-408
Ground Lead, 15 ft (4.5 m) 4702-7 Test Lead Set, 60 ft (18 m) including V1, V2,
RS232 Cable for connecting to a PC and Printer CA-RS232 Current and 30 ft (9 m) Jumper Lead 1001-425
Remote Hand Switch 30915-220 Test Lead Set, 100 ft (30 m) including V1, V2,
AC Power Cord (IEC60320-C13 to US standard) 17032 Current and 50 ft Jumper Lead 1001-451
AC Power Cord (IEC60320-C13 to Schuko CEE 7/7) 17032-13 Beacon Strobe Light 37181
Quick Start Guide 37178 Printer (includes battery/line powered serial thermal printer)
120 V, 60 Hz 1001-390
Canvas Carrying Bag (for leadset) 30915-211
230 V, 50 Hz 1001-401
CAT5e Patch Cable 36798
Foam-lined Transit Case 37009
Instruction Manual ATVMMTO210
USB to Ethernet Adapter 90001-541
PowerDB LITE
PowerDB (full version) Software,
1st machine license, soft key DB1001
PowerDB (full version) Software,
1st machine license, USB dongle DB1001S

UK UNITED STATES OTHER TECHNICAL SALES OFFICES Registered to ISO 9001:2000 Cert. no. 10006.01
Archcliffe Road, Dover 4271 Bronze Way Valley Forge USA, College Station MTO210_DS_en_V03
CT17 9EN England Dallas, TX 75237-1019 USA USA, Sydney AUSTRALIA, Tby www.megger.com
T +44 (0) 1 304 502101 T 1 800 723 2861 (USAonly) SWEDEN, Ontario CANADA, Trappes Megger is a registered trademark
F +44 (0) 1 304 207342 T +1 214 333 3201 FRANCE, Oberursel GERMANY, Aargau
UKsales@megger.com F +1 214 331 7399 SWITZERLAND, Kingdom of BAHRAIN, Specifications are subject to change

USsales@megger.com Mumbai INDIA, Johannesburg SOUTH without notice.


AFRICA, and Chonburi THAILAND

You might also like