SMM7 estimate example A PRELIMINARIES/GENERAL CONDITIONS

Qty Unit Rate p

A PRELIMINARIES/GENERAL CONDITIONS
A42 Contractor's general cost items: Services and
facilities
Provide the following services and facilities
Rubbish disposal
a Skips 3.00 nr 256.80 770 40
A44 Contractor's general cost items: Temporary
works
Scaffolding up to 10m high
Independent scaffolding
b Erect and subsequently dismantle 164.15 m2 16.14 2,649 38

Estimating Service 2016 Page 1 / 1 To Collection 3,419 78


SMM7 estimate example A PRELIMINARIES/GENERAL CONDITIONS

Qty Unit Rate p

Collection

Total from Page 1 / 1 3,419 78

Estimating Service 2016 Page 1 / 2 To Summary 3,419 78


SMM7 estimate example C EXISTING SITE/BUILDINGS/SERVICES

Qty Unit Rate p

C EXISTING SITE/BUILDINGS/SERVICES
C20 Demolition
Disconnect redundant services and demolish
individual structures to ground level; grub out slab and
foundations
Dispose of spoil off site; disposal costs included
within rates
a structure not exceeding 50 m3 39.67 m3 75.15 2,981 20
Pulling down - including removal of debris
Demolish external brickwork walls in cement
mortar; disposal of
debris off-site
b 215mm walls 25.84 m2 58.82 1,519 91
Demolish internal brick/blockwork in cement
mortar; disposal of
debris off-site
c 75 mm thick blockwork walls 14.05 m2 20.03 281 42
2
d 100 mm thick blockwork walls 48.00 m 25.93 1,244 64
2
e 140 mm thick blockwork walls 44.60 m 28.22 1,258 61
Demolishing parts of timber structures
Removing roof timbers
f including purlins, rafters, plates and ceiling joists;
dispose of debris off-site 106.93 m2 13.86 1,482 05
Softwood studded partitions; dispose of debris
off-site
g plasterboard finish 11.62 m2 15.48 179 88
Staircase; straight flight; dispose of debris off-site
h 900 mm wide 1.00 nr 132.32 132 32
C90 Alterations - spot items
Gutterwork
Remove gutters and supports, dispose of debris
off-site
i uPVC 28.58 m 6.76 193 20
Rainwater pipework
Remove rainwater pipes and supports, dispose of
debris off-site
j uPVC rainwater stack 14.21 m 6.76 96 06
Roof coverings
Stripping and repairs to slate and tile roofs
k plain or interlocking tiles; dispose of debris
off-site 113.98 m2 10.53 1,200 21

Estimating Service 2016 Page 2 / 1 To Collection 10,569 50


SMM7 estimate example C EXISTING SITE/BUILDINGS/SERVICES

Qty Unit Rate p

C EXISTING continued ...


C90 Alterations - spot items continued ...
Roof coverings continued ...
Stripping and repairs to slate and tile continued ...
a underfelt and nails; dispose of debris off-site 93.98 m2 1.46 137 21
b roofing felt or single ply waterproofing membrane;
dispose of debris
off-site 12.95 m2 6.73 87 15
2
c roofing battens; dispose of debris off-site 93.38 m 2.27 211 97
Removing fittings and fixtures
Timber mouldings
d skirtings, architraves or dado rail; dispose of
debris off-site or set aside for reuse 144.28 m 3.10 447 27
Doors including frame; dispose of debris off-site or
set aside for re-use
e single door 19.00 nr 17.53 333 07
f pair of French doors 1.00 nr 98.73 98 73
Windows; dispose of debris off-site or set aside for
re-use
g casement window 15.05 m2 27.06 407 25
Removing plumbing and engineering installations
Sanitary fittings, including capping off service and
waste pipes and
bringing forward services
h WC 2.00 nr 127.43 254 86
i wash hand basin 3.00 nr 39.68 119 04
j shower tray, shower fitting and screen 1.00 nr 211.28 211 28
k bath 1.00 nr 92.41 92 41
l sink unit 1.00 nr 72.57 72 57
Remove finishings
Floors
m linoleum 11.80 m2 3.91 46 14
2
n ceramic tiles 5.50 m 12.71 69 91
2
o carpeting 106.37 m 4.83 513 77
Ceilings
p plasterboard 140.58 m2 6.91 971 41
Block up openings in walls
Facing bricks in gauged mortar 1:3, faced one side
q 102.5 mm 0.51 m2 121.98 62 21

Estimating Service 2016 Page 2 / 2 To Collection 4,136 25


SMM7 estimate example C EXISTING SITE/BUILDINGS/SERVICES

Qty Unit Rate p

C EXISTING continued ...


C90 Alterations - spot items continued ...
Block up openings in walls continued ...
Blockwork in gauged mortar 1:4
a 100 mm 4.85 m2 56.77 275 33
Cut opening through existing floor structure
includes removing coverings; cutting structure;
trimming joists and making good finishes
b form new opening 1.00 nr 495.84 495 84

Estimating Service 2016 Page 2 / 3 To Collection 771 17


SMM7 estimate example C EXISTING SITE/BUILDINGS/SERVICES

Qty Unit Rate p

Collection

Total from Page 2 / 1 10,569 50

Total from Page 2 / 2 4,136 25

Total from Page 2 / 3 771 17

Estimating Service 2016 Page 2 / 4 To Summary 15,476 92


SMM7 estimate example D GROUNDWORK

Qty Unit Rate p

D GROUNDWORK
D20 Excavating and filling
Excavating by machine
To reduce levels, maximum depth not exceeding
a 1.00 m 9.53 m3 33.25 316 87
Trenches, width over 0.30 m, maximum depth not
exceeding
b 1.00 m 9.93 m3 33.25 330 17
Disposal
Off site to tip average 15 km from site
c loaded by grab wagon from spoil heaps 24.32 m3 24.26 590 00
Imported MOT Type 1 material
d not exceeding 0.25 m 1.25 m3 150.31 187 89
Surface treatments
Compacting
e surface of filling 25.08 m2 0.68 17 05
2
f bottom of excavation 25.08 m 0.68 17 05

Estimating Service 2016 Page 3 / 1 To Collection 1,459 03


SMM7 estimate example D GROUNDWORK

Qty Unit Rate p

Collection

Total from Page 3 / 1 1,459 03

Estimating Service 2016 Page 3 / 2 To Summary 1,459 03


SMM7 estimate example E IN SITU CONCRETE/LARGE PRECAST CONCRETE

Qty Unit Rate p

E IN SITU CONCRETE/LARGE PRECAST CONCRETE


E10 Mixing/casting/curing in-situ concrete
Ready mixed concrete
Plain in situ concrete 1:2:4 - 20 mm aggregate
a foundations 7.09 m3 150.09 1,064 14
b slabs, thickness not exceeding 150 mm 2.51 m3 150.09 376 73
3
c filling to hollow walls 0.35 m 198.20 69 37
E30 Reinforcement for in situ concrete
Fabric
Fabric reinforcement to BS 4483
d A393 - 6.16 kg/m2 1.55 m2 12.65 19 61
E41 Worked finishes/Cutting to in situ concrete
Worked finishes
Tamping by mechanical means
e level 42.80 m2 1.03 44 08

Estimating Service 2016 Page 4 / 1 To Collection 1,573 93


SMM7 estimate example E IN SITU CONCRETE/LARGE PRECAST CONCRETE

Qty Unit Rate p

Collection

Total from Page 4 / 1 1,573 93

Estimating Service 2016 Page 4 / 2 To Summary 1,573 93


SMM7 estimate example F MASONRY

Qty Unit Rate p

F MASONRY
F10 Brick/Block walling
Class B engineering bricks in cement mortar 1:3
Walls
a 102.5 mm 3.57 m2 93.06 332 22
Precast concrete dense aggregate blocks to BS 6073
Walls, facework one side
b 100 mm solid; in gauged mortar 1:3; below DPC
level 10.17 m2 39.54 402 12
c 100 mm solid; in gauged mortar 1:4; above DPC
level 97.16 m2 38.69 3,759 12
d 140 mm solid; in gauged mortar 1:4; above DPC
level 5.39 m2 46.87 252 63
Precast concrete lightweight aerated loadbearing
blocks to BS 6073
Walls
e 305 mm; trench blocks; below DPC level 3.47 m2 79.17 274 72
F30 Accessories/Sundry items for brick/block/stone
walling
Forming cavities
50 - 100 mm cavities in hollow walls with 225 mm
wall-ties at 5 per m2 using
f 3 mm vertical-twist ties 34.16 m2 2.13 72 76
Closing cavities
Thermabate cavity closers
g 100 mm cavity 26.70 m 10.76 287 29
Damp proof courses
Polythene
h horizontal 100mm wide 30.18 m 0.74 22 33
Cavity trays
Type W Cavity weep ventilator
i wall weep vent 35.00 nr 1.61 56 35
Polythene
j horizontal exceeding 225 mm 7.54 m2 12.78 96 36
Stop Ends
k lintel stop end 16.00 nr 2.13 34 08
Proprietary items
Wall extension profiles, single flange, plugging and
screwing
l 100mm 10.44 m 11.30 117 97

Estimating Service 2016 Page 5 / 1 To Collection 5,707 95


SMM7 estimate example F MASONRY

Qty Unit Rate p

F MASONRY continued ...


F30 Accessories/Sundry items for brick/block/stone
walling continued ...
Galvanised steel lintels
Galvanised steel standard lintels
a 1050mm 1.00 nr 37.88 37 88
b 1350mm 4.00 nr 48.28 193 12
c 1500mm 3.00 nr 54.38 163 14
d 1950mm 1.00 nr 76.96 76 96
F31 Precast concrete sills/lintels/copings/features
Padstones
Padstones bedded
e 215 x 100 x 300 mm 2.00 nr 28.58 57 16
f 215 x 100 x 440 mm 3.00 nr 36.11 108 33
g 215 x 100 x 600 mm 2.00 nr 55.53 111 06
Lintels
Prestressed lintels 65 mm x 100 mm bedded
h 600 mm 6.00 nr 19.96 119 76
i 1200 mm 3.00 nr 25.45 76 35
Prestressed lintels 65 mm x 140 mm bedded
j 1650 mm 2.00 nr 36.28 72 56

Estimating Service 2016 Page 5 / 2 To Collection 1,016 32


SMM7 estimate example F MASONRY

Qty Unit Rate p

Collection

Total from Page 5 / 1 5,707 95

Total from Page 5 / 2 1,016 32

Estimating Service 2016 Page 5 / 3 To Summary 6,724 27


SMM7 estimate example G STRUCTURAL/CARCASSING METAL/TIMBER

Qty Unit Rate p

G STRUCTURAL/CARCASSING METAL/TIMBER
G10 Structural steel framing
Framing, fabrication
Fabricated steelwork
a columns less than 40 kg/m 1.28 tonne 1922.92 2,461 34
b columns less than 40 kg/m SHS 0.46 tonne 2380.11 1,094 85
c columns 40 - 100 kg/m 0.63 tonne 1681.30 1,059 22
d beams less than 40 kg/m 0.39 tonne 2040.58 795 83
Connections
e general steel connections 37.00 nr 69.52 2,572 24
Erection on site
f permanent erection 2.76 tonne 583.23 1,609 71
Surface treatments at fabrication workshop
g shot blasting & priming 78.59 m2 9.47 744 25
2
h 30 minute intumescent fire paint 78.59 m 15.94 1,252 72
G20 Carpentry/Timber framing/First fixing
Impregnated sawn softwood - SC3 Grade
Floor members
i 25 x 50mm 94.06 m 2.90 272 77
j 50 x 75mm 15.00 m 3.99 59 85
k 50 x 200mm 176.24 m 7.73 1,362 34
Wall or partition members
l 50 x 100mm 232.50 m 5.94 1,381 05
m 50 x 150mm 161.24 m 7.22 1,164 15
Pitched roof members
n 25 x 225mm 8.10 m 6.26 50 71
o 50 x 50mm 75.50 m 4.35 328 43
p 50 x 100mm 27.66 m 6.01 166 24
q 50 x 150mm 40.32 m 7.48 301 59
r 50 x 200mm 297.97 m 8.45 2,517 85
s 63 x 225mm 37.92 m 12.44 471 72
t 75 x 225mm 14.25 m 17.24 245 67
Solid bridging between joists (measured over the
joists)
u 50 x 200mm 11.34 m 10.62 120 43
v Notch and fit ends of members to metal 50.00 nr 5.93 296 50
Eaves and verge boarding
uPVC
w 250 x 18mm fascia board 32.77 m 14.49 474 84

Estimating Service 2016 Page 6 / 1 To Collection 20,804 30


SMM7 estimate example G STRUCTURAL/CARCASSING METAL/TIMBER

Qty Unit Rate p

G STRUCTURAL/CARCASSING continued ...


G20 Carpentry/Timber framing/First continued ...
Eaves and verge boarding continued ...
uPVC continued ...
a 150 x 18mm barge board 4.98 m 9.85 49 05
b 225 x 10mm vented soffit board 37.75 m 9.84 371 46
Metalwork
Galvanised steel joist hangers - built in
c 50 x 200mm 56.00 nr 4.50 252 00
Speedy joist hangers
d 50mm 3.00 nr 3.38 10 14
e 100mm 2.00 nr 4.94 9 88
Galvanised steel straps
f light duty wall plate strap; once bent; 1200 mm
long 15.00 nr 8.83 132 45
g heavy duty steel strap; once bent; 1200 mm long 15.00 nr 12.07 181 05

Estimating Service 2016 Page 6 / 2 To Collection 1,006 03


SMM7 estimate example G STRUCTURAL/CARCASSING METAL/TIMBER

Qty Unit Rate p

Collection

Total from Page 6 / 1 20,804 30

Total from Page 6 / 2 1,006 03

Estimating Service 2016 Page 6 / 3 To Summary 21,810 33


SMM7 estimate example H CLADDING/COVERING

Qty Unit Rate p

H CLADDING/COVERING
H60 Plain roof tiling
Sub-contract purchase
Clay plain tiles; Dreadnought machine made
smooth red or other
equal and approved on 19 x 38mm treated battens
and breather membrane
a roof coverings to 64mm lap 119.84 m2 56.59 6,781 75
2
b wall coverings to 38mm lap 39.06 m 60.17 2,350 24
Extra over for
c double course at eaves 54.61 m 13.01 710 48
d verges; single undercloak course 4.98 m 11.37 56 62
e valleys; cutting both sides 11.07 m 28.13 311 40
f ridge tiles 8.10 m 35.31 286 01
g bonnet hip tiles; cutting both sides 26.85 m 92.68 2,488 46
h external vertical angle tiles 5.18 m 97.18 503 39
i hip irons 5.00 nr 4.39 21 95
H71 Lead sheet coverings/flashings
Flashings, aprons
Code 4 lead, horizontal, 150 mm lapped joints
j 300 mm girth 23.35 m 25.37 592 39
Code 4 lead, stepped, 150 mm lapped joints
k 300 mm girth 11.38 m 33.17 377 47

Estimating Service 2016 Page 7 / 1 To Collection 14,480 16


SMM7 estimate example H CLADDING/COVERING

Qty Unit Rate p

Collection

Total from Page 7 / 1 14,480 16

Estimating Service 2016 Page 7 / 2 To Summary 14,480 16


SMM7 estimate example J WATERPROOFING

Qty Unit Rate p

J WATERPROOFING
J40 Flexible sheet tanking/ damp proof
membranes
Tanking and damp proofing
Polythene medium weight sheet underlay lapped
150 mm at joints
a horizontally 30.52 m2 1.84 56 16

Estimating Service 2016 Page 8 / 1 To Collection 56 16


SMM7 estimate example J WATERPROOFING

Qty Unit Rate p

Collection

Total from Page 8 / 1 56 16

Estimating Service 2016 Page 8 / 2 To Summary 56 16


SMM7 estimate example K LININGS/SHEATHING/DRY PARTITIONING

Qty Unit Rate p

K LININGS/SHEATHING/DRY PARTITIONING
Linings, gypsum plasterboard to BS 1230
Fixing with plaster dabs to masonry backgrounds
a 12.5 mm Plain Wallboard over 300 mm wide 189.05 m2 12.10 2,287 51
b 12.5 mm Moisture Resistant Board over 300 mm
wide 26.47 m2 14.34 379 58
c 12.5 mm Plain Wallboard not exceeding 300 mm
wide 46.73 m 5.77 269 63
Fixing with screws to timber or steel stud framing
d 12.5 mm Plain Wallboard over 300 mm wide 119.05 m2 11.51 1,370 27
e 12.5 mm Moisture Resistant Board over 300 mm
wide 34.78 m2 13.51 469 88
f 12.5 mm Plain Wallboard not exceeding 300 mm
wide 17.90 m 5.54 99 17
Fixing with screws to ceilings
g 12.5 mm Vapour Check Board over 300 mm wide 152.69 m2 15.10 2,305 62
K11 Rigid sheet flooring/sheathing/linings/casings
Sheet linings and casings
WBP external plywood
h 12mm WBP plywood to walls 41.93 m2 16.46 690 17
K20 Timber board
flooring/sheathing/linings/casings
Flooring
Chipboard Type C4 flooring tongued and grooved all
edges, width
exceeding 300 mm, thickness
i 22mm 59.30 m2 15.41 913 81

Estimating Service 2016 Page 9 / 1 To Collection 8,785 64


SMM7 estimate example K LININGS/SHEATHING/DRY PARTITIONING

Qty Unit Rate p

Collection

Total from Page 9 / 1 8,785 64

Estimating Service 2016 Page 9 / 2 To Summary 8,785 64


SMM7 estimate example L WINDOWS/DOORS/STAIRS

Qty Unit Rate p

L WINDOWS/DOORS/STAIRS
L10 Windows/rooflights/screens/louvres
Roof windows
Velux roof windows in treated Nordic red pine;
exterior aluminium
cladding; factory double glazed sealed units;
screwed to softwood
a 660 x 1180 mm GPU FK06 1.00 nr 458.08 458 08
b 780 x 1180 mm GPU MK06 1.00 nr 494.31 494 31
c 780 x 1400 mm GGL MK08 1.00 nr 603.74 603 74
L20 Doors/shutters/hatches
Flush doors
Moulded panel doors; white base coated facings
suitable for paint finish only, two, four or six panel
options
d 457 x 1981 x 35mm 2.00 nr 42.23 84 46
e 610 x 1981 x 35mm 4.00 nr 42.23 168 92
f 726 x 1981 x 35mm 8.00 nr 39.78 318 24
Softwood door frames and linings
Door lining sets
g 32 x 115mm internal door lining with loose stops 6.00 nr 32.48 194 88
h 32 x 140mm internal door lining with loose stops 8.00 nr 34.88 279 04
L30 Stairs/walkways/balustrades
Purpose made staircases
Softwood stairs; 25mm thick treads with rounded
nosing's, 9mm
plywood risers, 32mm thick strings. 50 x 75mm
handrail with 32mm
square plain balusters and 100mm square plain
newel posts
i dogleg staircase; up to 2600 mm rise; up to 838
mm wide with two newel posts 1.00 nr 1136.73 1,136 73
Newel Posts
Softwood
j 94 mm x 94 mm full newel post 1.00 nr 46.34 46 34
k 44 mm x 94 mm half newel post 1.00 nr 22.07 22 07
Newel Caps
Softwood
l 100 mm x 100 mm x 50 mm 1.00 nr 13.42 13 42
m 50 mm x 100 mm x 50 mm 1.00 nr 7.88 7 88

Estimating Service 2016 Page 10 / 1 To Collection 3,828 11


SMM7 estimate example L WINDOWS/DOORS/STAIRS

Qty Unit Rate p

L WINDOWS/DOORS/STAIRS continued ...


L30 Stairs/walkways/balustrades continued ...
Balustrade
Softwood; 50 x 75mm handrail, 32mm square plain
balusters
a 3.00m long 1.00 nr 205.03 205 03

Estimating Service 2016 Page 10 / 2 To Collection 205 03


SMM7 estimate example L WINDOWS/DOORS/STAIRS

Qty Unit Rate p

Collection

Total from Page 10 / 1 3,828 11

Total from Page 10 / 2 205 03

Estimating Service 2016 Page 10 / 3 To Summary 4,033 14


SMM7 estimate example M SURFACE FINISHES

Qty Unit Rate p

M SURFACE FINISHES
M20 Plastered/Rendered/Roughcast coatings
Cement and sand 1:3, work to walls, externally
16 mm two coat wood floated finish on brick or
block walls
a over 300 mm wide 17.83 m2 32.37 577 16
b not exceeding 300 mm wide 33.91 m 16.65 564 60
Retarded hemihydrate gypsum ("Thistle") plasters to
BS 1191, Class B
3 mm board finish on walls or ceilings including
scrimming joints
c over 300 mm wide 613.48 m2 9.40 5,766 71
d not exceeding 300 mm wide 64.63 m 4.76 307 64
Plastering sundries
Galvanised plaster beads
e thin coat angle bead 56.18 m 2.18 122 47
Plastic plaster beads
f angle bead 33.91 m 3.12 105 80
g stop bead 15.64 m 8.12 127 00
M40 Stone/Concrete/Quarry/Ceramic tiling/Mosaic
Floor Tiles
Fixing with adhesive
h over 300 mm wide; to kitchen, utility and all
bathrooms; PC supply rate for tiles 30/m2 32.00 m2 91.25 2,920 00
Wall Tiles
Fixing with adhesive
i over 300 mm wide; PC supply rate for tile 30/m2 68.80 m2 90.20 6,205 76
M51 Edge fixed carpeting
Underlay
Latex carpet underlay to floors level and to falls not
exceeding 15 degrees from horizontal on timber
base
j exceeding 300 m wide 118.55 m2 2.66 315 34
Fitted carpet
Medium duty tufted wool/nylon carpet fixed with
gripper rods to floors level and to floors not
exceeding 15 degrees from horizontal on timber
base
k exceeding 300 m wide 118.55 m2 42.14 4,995 70

Estimating Service 2016 Page 11 / 1 To Collection 22,008 18


SMM7 estimate example M SURFACE FINISHES

Qty Unit Rate p

M SURFACE FINISHES continued ...


M60 Painting/Clear finishing
General surfaces
One mist coat and two coats of trade matt
emulsion paint over 300 mm girth
a smooth plaster 460.79 m2 5.00 2,303 95
Knot, prime, stop and paint one undercoat and one
coat of gloss
finish paint on joinery
b over 300 mm girth 45.36 m2 6.28 284 86
c isolated surfaces, not exceeding 300 mm girth 284.55 m 2.39 680 07

Estimating Service 2016 Page 11 / 2 To Collection 3,268 88


SMM7 estimate example M SURFACE FINISHES

Qty Unit Rate p

Collection

Total from Page 11 / 1 22,008 18

Total from Page 11 / 2 3,268 88

Estimating Service 2016 Page 11 / 3 To Summary 25,277 06


SMM7 estimate example N FURNITURE/EQUIPMENT

Qty Unit Rate p

N FURNITURE/EQUIPMENT
N13 Sanitary appliances/fittings
Supply & fix equipment
Sub-contract purchase
a WC 3.00 nr 365.32 1,095 96
b wash hand basin 3.00 nr 205.44 616 32
c bath 1.00 nr 272.49 272 49
d shower valve 3.00 nr 474.73 1,424 19
e stainless steel inset sink and taps 1.00 nr 442.25 442 25
f 760 x 760 mm shower tray 1.00 nr 238.07 238 07
g alcove shower enclosure 2.00 nr 203.14 406 28

Estimating Service 2016 Page 12 / 1 To Collection 4,495 56


SMM7 estimate example N FURNITURE/EQUIPMENT

Qty Unit Rate p

Collection

Total from Page 12 / 1 4,495 56

Estimating Service 2016 Page 12 / 2 To Summary 4,495 56


SMM7 estimate example P BUILDING FABRIC SUNDRIES

Qty Unit Rate p

P BUILDING FABRIC SUNDRIES


P10 Sundry insulation/proofing work/fire stops
Insulating quilts
Loft insulation, thermal insulating quilts
a 100 mm thick Isover 140.58 m2 3.13 440 02
b 170 mm thick Isover 88.45 m2 4.54 401 56
Insulating boards
Celotex Insulation Fast-R range
c 40 mm 8.70 m2 15.58 135 55
2
d 100 mm 50.63 m 32.12 1,626 24
e 120 mm 14.88 m2 30.55 454 58
Cavity wall Insulation
Slab insulation to masonry walls
f 100 mm thick Drytherm 37 Earthwool cavity
insulation 27.36 m2 13.70 374 83
Vapour barriers
Vapour barriers to timber background
g Polythene vapour barrier 41.93 m2 2.32 97 28
P20 Unframed isolated trims/skirtings/sundry items
Skirtings, picture rails, architraves and the like
Wrought softwood skirtings
h 25 x 150 mm Torus 154.55 m 5.49 848 48
Wrought softwood architraves
i 25 x 75 mm, Ogee 130.00 m 4.29 557 70
Window boards
MDF with rounded nosing
j 25 x 219 mm 23.22 m 11.29 262 15
k returned ends 28.00 nr 1.19 33 32
P21 Ironmongery
Fixing to Softwood or Hardwood
Latches
l 75mm mortice latch 8.00 nr 22.06 176 48
Locks
m bathroom privacy lock 3.00 nr 29.20 87 60
Butt hinges
n 75mm 21.00 pair 9.45 198 45
Door handles
o lever latch handles 11.00 pair 24.32 267 52
p lever latch WC handles 3.00 pair 27.38 82 14

Estimating Service 2016 Page 13 / 1 To Collection 6,043 90


SMM7 estimate example P BUILDING FABRIC SUNDRIES

Qty Unit Rate p

Collection

Total from Page 13 / 1 6,043 90

Estimating Service 2016 Page 13 / 2 To Summary 6,043 90


SMM7 estimate example R DISPOSAL SYSTEMS

Qty Unit Rate p

R DISPOSAL SYSTEMS
R10 Rainwater pipework/gutters
Unplasticised PVC rainwater pipework to BS 4576
68 mm pipework
a fixed with brackets plugged to walls 8.42 m 11.30 95 15
Extra for
b 228mm offset swan-neck 2.00 nr 12.11 24 22
Unplasticised PVC gutterwork to BS 4576
112 mm half round gutters
c jointed and fixed with support and union brackets
screwed to timber 41.82 m 11.18 467 55
Extra for
d angles 5.00 nr 10.32 51 60
e stopped ends 7.00 nr 4.37 30 59
f outlets 4.00 nr 9.24 36 96
R11 Foul drainage above ground
Sub-contract purchase
g 32mm waste pipe including elbows and branches 9.00 m 8.99 80 91
h 40mm waste pipe including elbows and branches 9.00 m 10.64 95 76
i stub soil stack 1.00 nr 492.77 492 77
R12 Drainage below ground
Excavation by machine
Trenches for drain pipes not exceeding 200 mm
nominal size,
grading bottoms, earthwork support and backfilling
with excavated
material; average depth
j 1.00 m 30.87 m 26.11 806 02
Disposal of material arising from drainage excavations
Excavated material; bulking factor 1.25
k loaded by grab wagon from spoil heaps 5.21 m3 24.26 126 39
Imported granular material
150 mm beds and side filling to half height of pipes
l 450 mm wide to 100 mm pipes 30.87 m 14.80 456 88
Unplasticised PVC pipes and fittings to BS 4660
110 mm pipes
m in trenches 30.87 m 10.31 318 27
Extra for
n short radius bends 4.00 nr 13.42 53 68
o long radius bends 3.00 nr 17.31 51 93

Estimating Service 2016 Page 14 / 1 To Collection 3,188 68


SMM7 estimate example R DISPOSAL SYSTEMS

Qty Unit Rate p

R DISPOSAL SYSTEMS continued ...


R12 Drainage below ground continued ...
Unplasticised PVC pipes and fittings to continued ...
Extra for continued ...
a slip coupler 4.00 nr 5.62 22 48
Accessories
b bottle gully 3.00 nr 78.33 234 99
c back inlet bottle gully 1.00 nr 95.89 95 89
Surface drainage systems
ACO Drain Raindrain channel with galvanised steel
lockable grating
d set in ground, bedded and haunched in concrete 1.01 m 150.89 152 40
e extra for end cap 2.00 nr 8.51 17 02
Manholes
Unplasticised PVC inspection chambers 450 mm
diameter; set in cement mortar 1:3, depth to invert
f 1035 mm 1.00 nr 225.14 225 14
Testing drains
Water test
g 100 mm drains 30.87 m 1.66 51 24

Estimating Service 2016 Page 14 / 2 To Collection 799 16


SMM7 estimate example R DISPOSAL SYSTEMS

Qty Unit Rate p

Collection

Total from Page 14 / 1 3,188 68

Total from Page 14 / 2 799 16

Estimating Service 2016 Page 14 / 3 To Summary 3,987 84


SMM7 estimate example S PIPED SUPPLY SYSTEMS

Qty Unit Rate p

S PIPED SUPPLY SYSTEMS


S10 Cold Water
Sub-contract purchase
a cold water point 11.00 nr 176.33 1,939 63
S11 Hot water
Sub-contract purchase
b hot water point 8.00 nr 301.75 2,414 00

Estimating Service 2016 Page 15 / 1 To Collection 4,353 63


SMM7 estimate example S PIPED SUPPLY SYSTEMS

Qty Unit Rate p

Collection

Total from Page 15 / 1 4,353 63

Estimating Service 2016 Page 15 / 2 To Summary 4,353 63


SMM7 estimate example T MECHANICAL HEATING/COOLING/REFRIGERATION SYSTEMS

Qty Unit Rate p

T MECHANICAL HEATING/COOLING/REFRIGERATION
SYSTEMS
T73 Works associated with Heating installations
Sub-contract purchase
a central heating service point 14.00 nr 605.42 8,475 88
b 500mm radiator with TRV 1.00 nr 189.16 189 16
c 1000mm radiator with TRV 6.00 nr 209.01 1,254 06
d 700mm towel rail 3.00 nr 202.58 607 74
e Worcester Bosch boiler; Greenstar CDI Classic,
34KW 1.00 nr 1892.58 1,892 58
f 800mm radiator with TRV 2.00 nr 187.16 374 32
g 1200mm radiator with TRV 2.00 nr 215.01 430 02

Estimating Service 2016 Page 16 / 1 To Collection 13,223 76


SMM7 estimate example T MECHANICAL HEATING/COOLING/REFRIGERATION SYSTEMS

Qty Unit Rate p

Collection

Total from Page 16 / 1 13,223 76

Estimating Service 2016 Page 16 / 2 To Summary 13,223 76


SMM7 estimate example V ELECTRICAL SUPPLY/POWER LIGHTING SYSTEMS

Qty Unit Rate p

V ELECTRICAL SUPPLY/POWER LIGHTING


SYSTEMS
V21 General lighting
Sub-contract purchase
a 1-Gang, 1-Way: Light switch: White 7.00 nr 39.60 277 20
b 1-Gang, 2-Way: Light switch: White 2.00 nr 46.19 92 38
c 2-Gang, 2-Way: Light switch: White 5.00 nr 81.31 406 55
d ceiling rose; White 3.00 nr 52.73 158 19
e downlighter 85.00 nr 58.19 4,946 15
f photocell floodlight 7.00 nr 197.02 1,379 14
g cabinet light 4.00 nr 40.83 163 32
V22 General Low Voltage power
Sub-contract purchase
Complete supply & fix installations
h 1-Gang switched socket outlet; White 1.00 nr 30.27 30 27
i 2-Gang switched socket outlet; White 46.00 nr 39.46 1,815 16
j 1-Gang external switched socket outlet 1.00 nr 147.73 147 73
k non-illuminated fused spur 10.00 nr 44.35 443 50
l shaver socket 3.00 nr 78.63 235 89
m extractor fan 5.00 nr 71.66 358 30
n boiler electrics 1.00 nr 594.95 594 95
o consumer unit 1.00 nr 596.80 596 80
p earth bonding 1.00 nr 216.87 216 87
q testing & commissioning 1.00 nr 107.86 107 86
V23 Smoke/Heat/Gas alarms
Sub-contract purchase
Complete supply & fix installations
r smoke/heat/gas alarm 2.00 nr 93.05 186 10
V24 Telecoms and Data
Sub-contract purchase
Complete supply & fix installations
s BT point - master 1.00 nr 28.01 28 01
t BT point - slave 2.00 nr 25.26 50 52
u TV point 3.00 nr 38.81 116 43
v Data point 3.00 nr 45.94 137 82

Estimating Service 2016 Page 17 / 1 To Collection 12,489 14


SMM7 estimate example V ELECTRICAL SUPPLY/POWER LIGHTING SYSTEMS

Qty Unit Rate p

Collection

Total from Page 17 / 1 12,489 14

Estimating Service 2016 Page 17 / 2 To Summary 12,489 14


SMM7 estimate example

Qty Unit Rate p

Summary

A PRELIMINARIES/GENERAL ... Page 1 / 2 3,419 78

C EXISTING SITE/BUILDINGS/SERVICES Page 2 / 4 15,476 92

D GROUNDWORK Page 3 / 2 1,459 03

E IN SITU CONCRETE/LARGE ... Page 4 / 2 1,573 93

F MASONRY Page 5 / 3 6,724 27

G STRUCTURAL/CARCASSING ... Page 6 / 3 21,810 33

H CLADDING/COVERING Page 7 / 2 14,480 16

J WATERPROOFING Page 8 / 2 56 16

K LININGS/SHEATHING/DRY ... Page 9 / 2 8,785 64

L WINDOWS/DOORS/STAIRS Page 10 / 3 4,033 14

M SURFACE FINISHES Page 11 / 3 25,277 06

N FURNITURE/EQUIPMENT Page 12 / 2 4,495 56

P BUILDING FABRIC SUNDRIES Page 13 / 2 6,043 90

R DISPOSAL SYSTEMS Page 14 / 3 3,987 84

S PIPED SUPPLY SYSTEMS Page 15 / 2 4,353 63

T MECHANICAL ... Page 16 / 2 13,223 76

V ELECTRICAL SUPPLY/POWER ... Page 17 / 2 12,489 14

Estimating Service 2016 Page S / 1 Total for Bill 147,690 25