Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Linease Actuator CAHB 22E - 17210 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Linear actuator

CAHB 22 E series

Features:
High force
High speed
High holding force
Mechanical overload protection
Enhanced ingress protection
Corrosion protection and stainless
steel tube
Manual override option
Virtuality maintenance free

Beneits:
High productivity
Reliability and safety
Save development time
Cost effectiveness
109,3 (with signal) 127 (with manual override)

107 (no manual


74,3 (without signal) override)
76,5 Max 500 min
2,5
GORE Automotive vent

0,3 16 63,5
21 0,1

15,5 Min D1 H11


151 Max

09

0

06

02

0350

03
0

0 0,6 0
26,0 62,4 28,6 0
0

0,1 0 0,1
38,3 0
05
03

Max

02

06
0

09


D2 H11
15,5
0,3
11,5 0,7
0,5
12,8 0,4 Retracted length L1 (0,+4) Stroke length L2

90 120 150
60
09

09

09

09

09

09
0


06

06

06

06

06

06
12

12

12

12

12

12
0
30 0 0 0 0 0

15 15 15 15 15 15
03 03 03 03 03 03

0 0
0
0
0
0
0
0
0
0
0
0
0

03 03 03 03 03 03
15 15 15 15 15 15

0 0 0 0 0 0
12

12

12

12

12

12
06

06

06

06

06

06
0

0
09

09

09

09

09

09


3 1 2 Inner side of motor front
Unscrew the motor cover (1). Use
the slot (2) to rotate the motor
shaft (3) in the proper direction
te n s i o n
Re
tra c ti o

Ex

No option2) With limit switch1) With signal2) With limit switch and signal1)

L2 Stroke [mm] 100 305 306 700 100 305 306 700 100 305 306 700 100 305 306 700
L1 retracted length 194 + stroke 229 + stroke 200 + stroke 235 + stroke 229 + stroke 264 + stroke 235 + stroke 270 + stroke
Tolerance L2: Stroke S
1) Tolerance S: if S 305: (2); if S>305: (3)
2) Tolerance S: for CAHB22 3E/4E if S 305: (2, 0,5); if S>305: (3, 1); for CAHB22 1E/2E if S 305: (3, 1,5); if S>305: (4, 2)

Speed and load Current load Static load

Current consumption [A]


Speed [mm/s] 12 V DC 24 V DC Load [kN]
60 25 12,5 24
50 2 3 20
1 20 1 10
40 4
2 16
15 7,5
30 12
20 10 5
3 8
4 5 2,5
10 4
0 0 0 0
0 2 4 6 8 10 0 2 4 6 8 10 0 200 400 600 800
Load [kN] Load [kN] Stroke length [mm]

Load variant 1 Load variant 1 Ultimate CAHB-22-xxE (push)


Load variant 2 Load variant 2 Ultimate CAHB-22-xxE (pull)
Load variant 3 Load variant 3 Recommended CAHB 22-xxE (push)
Recommended CAHB 22-xxE (pull)

2
Technical data CAHB 22

Designation Symbol Unit CAHB 22 / 12 V CAHB 22 / 24 V

Performance data
Rated Push Force Push F N 2 300 3 500 6 800 10 000 2 300 3 500 6 800 10 000
Rated Pull Force Pull F N 2 300 3 500 6 800 10 000 2 300 3 500 6 800 10 000
Max pull / push Force1) N 3 500 4 900 9 500 14 000 3 500 4 900 9 500 14 000
Holding force2) N
Speed without load Vo mm/s 55,0 45,0 22,0 13,0 53,0 45,0 22,0 13,0
Speed with the rated force V mm/s 42,0 36,0 15,5 10,2 42,0 37,0 17,0 10,2

Electric data
Nominal voltage U V DC 12 12 12 12 24 24 24 24
Rated current I A 20,5 22,0 23,0 21,5 9,5 11,0 11,0 10,0
Duty cycle - % 10% 10% 10% 10% 20% 20% 20% 20%
(85/765 s) (85/765 s) (85/765 s) (85/765 s) (85/340 s) (85/340 s) (85/340 s) (85/340 s)

Mechanical data
Stroke s mm 50 700 50 700 50 610 50 450 50 700 50 700 50 610 50 450
Backlash sbacklash mm 1,0 1,0 0,6 0,6 1,0 1,0 0,6 0,6
Weight for 200 mm stroke kg 4,8 4,8 4,8 4,8 4,8 4,8 4,8 4,8
Colour Black Black Black Black Black Black Black Black

Environment and standards


Ambient temperature Tambient C 40 85 40 85 40 85 40 85 40 85 40 85 40 85 40 85
Degree of protection IP 69K/66M
Standards / EMC EN61000-6-2:2005, EN61000-6-4:2007/A1:2011
Salt spray test ISO 9227:2012, 250 hours
1) Upper limit of the pull/push force limited by the clutch
2) Ultimate Static Load, refer to the Static load diagrams

Electrical specification Feedback resolution list

Actuator type Hall sensor resolution POT resolution


[pulses/mm] [ohm/mm]
Wire connection with no signal

Wire no. AWG Colour Application


CAHB-221E 1,4 30 if S = 050-222
CAHB-222E 1,4 15 if S = 223-444
5 if S = 445-700
1 14 Red Motor power(+)=> Extension,
()=> Retraction CAHB-223E 2,8 60 if S = 050-222
2 14 Black Motor power()=> Extension, CAHB-224E 2,8 30 if S = 223-444
(+)=> Retraction 10 if S = 445-700

Wire connection with potentiometer Potentiometer

Wire no. AWG Colour Application Retract Extend

1 22 Green See picture description


2 22 White See picture description
3 22 Brown See picture description Limit+POT: White Green Brown
4 14 Red Motor power(+)=> Extension, ()=> Retraction 0 K Ohm CW 10 K Ohm
5 14 Black Motor power()=> Extension, (+)=> Retraction

Wire connection with encoder Encoder


Signal CCW extension
Wire no. AWG Colour Application
Hall 1

1 26 Green Sensor signal 1 Encoder Hall 2


2 26 Yellow Sensor signal 2 Encoder Signal CW retraction
3 26 Black Sensor power GNO Encoder
4 26 Red Sensor power 5 V Encoder Hall 1
5 14 Red Motor power(+)=> Extension, ()=> Retraction
6 14 Black Motor power()=> Extension, (+)=> Retraction Hall 2

3
Ordering key C A H B 2 2 E B T 0 0 0

Type

Voltage
12 V DC A
24 V DC B
12 V DC with manual override E
24 V DC with manual override F

Load
2 300 N 1
3 500 N 2
6 800 N 3
10 000 N 4

Design E

Stroke (mm)
100 100
150 150
200 200
250 250
300 300
350 350
400 400
450 450
500 500
600 600
700 700

Retracted length
For a stroke length Retracted length (mm)
With LS Without POT or encoder With POT or encoder
100 300 335
150 350 385
200 400 435
250 450 485
300 500 535
350 585 620
400 635 670
450 685 720
500 735 770
600 835 870
700 935 970
Without LS
100 294 329
150 344 379
200 394 429
250 444 479
300 494 529
350 579 614
400 629 664
450 679 714
500 729 764
600 829 864
700 929 964

Ingress protection
Standard: IP69K/IP66M B

Attachment diameter: (Front and rear)


Hole 13,1 H11 (+0, +0,11 mm) A
Hole 12,8 H11 (0, +0,11 mm) B
Hole 12,5 H11 (+0, +0,11 mm) C
Customized X

Attachment orientation:
Standard (0) A
30 B
60 C
90 D
120 E
150 F
Customized X

Option 1: L.S (Limit switch)


None (mandatory for 2 300 N and 3 500 N version) 0
Limit switch (valid only for load version 6 800 N and 10 000 N, not mandatory for 10 000 N) L

Option 2: Feedback
None 0
Potentiometer P
Encoder E

Thermal protection
Standard: Built-in thermal switch T

Customization
Stroke length, retracted length, cable, connector, front attachment, rear attachment, color, de-rated load

Notes: In standard, the actuators are IP69K / IP66M and equipped with GORE Automotive vent, built-in thermal protection, protection Clutch and EMC ilter.

SKF is a registered trademark of the SKF Group.

SKF Group 2017


The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P2 17210 EN March 2017

You might also like