Direct Current Ammeters: Dms Application Note
Direct Current Ammeters: Dms Application Note
Direct Current Ammeters: Dms Application Note
1.0 Ampere
Basic Ammeter Example
0.1
The circuit shown in Figure 1 illustrates a typical digital ammeter Current
Shunt
consisting of a +5Vdc power supply, a 0.1 current shunt, and a Load
DATEL, Inc., Mansfield, MA 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com
www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Figure 2 differs from Figure 1 in one very important respect: the Figure 3 shows the correct connections for a typical two-meter
current shunt is located in the high side of the system power supply. application. The DC/DC converter is required because the 0.1
As previously stated, this is the most popular and the most current shunt is connected to the positive terminal of the 12V battery.
troublesome ammeter configuration in use. This type of hookup If the shunt was connected in the negative side of the battery (low
requires the use of a DC/DC converter to provide the necessary side), both meters could be powered from the LM7805CT regulator.
isolation between the meter's 5V power source and the system The DC/DC converter would not be required. Please note that while
power supply. If the DC/DC converter is not used, the meters inputs the LM7805CT can power as many as 10 DMS-30PC-X-RL (low-
(()INPUT LO and (+)INPUT HI) will be at, or very close to, +5V. This power red LED) meters, it can only supply power to one standard-
condition violates the common-mode voltage limit of 2V and will intensity DMS-30PC meter.
overrange the meter. DMS-EB-DC/DC Application Board
12V-Powered Ammeters DATEL's DMS-EB-DC/DC application board, with its built-in
As a general rule, all ammeters using high-side current shunts DC/DC converter, greatly simplifies the connections required for
must use an isolating DC/DC converter. Ignoring this rule could ammeters with high-side current shunts. As shipped, the DMS-EB-
result in serious damage to the meter, particularly if power system DC/DC board will provide an isolated 5V output from a
voltages greater than +6Vdc are used. Systems that use two meters, 4.5-5.5V input. If only 12V power is available, the user can easily
one for Amperes, the other for Volts, even if a DC/DC converter is install an LM7805CT voltage regulator. See the DMS-EB-DC/DC
used, can still be troublesome. data sheet for more information.
DMS-30PC-0-GS
1
8
+5V REF OUT
+ + +
+5V VIN VOUT
3
5V RET
7
REF IN
DC/DC
Converter 6 12 11
DP1 () IN LO (+) IN HI
0.1V
1.0 Ampere
Load +5V
0.1
+4.9V Current
Shunt
3
5V RET
5
DP2
DMS-30PC-2-RL
LM7805CT (Voltmeter) +
1
+5V VOUT 12 11 7 8
IN OUT () IN LO (+) IN HI REF IN REF OUT
GND 3
5V RET
+ 5 DC/DC 0.1V
DP2 Converter
+12V VIN
12 11 7 8 + +11.9V
() IN LO (+) IN HI REF IN REF OUT
Load +12V
0.1
1.0 Ampere Current Shunt