The unique

SIGMAMETER automated
Quality/Control
instrument
for ferromagnetic
compound
s determination

s:
Specific
saturation
magnetization

Excellence in thermal analysis and calorimetry


2
Sigmameter
The magnetic specifications of a ferromagnetic compound may vary to a very large extent further to
mechanical and/or thermal treatments. The variations in the magnetic specifications are taken into account by
the specialist in order to study the evolution of some solid state transitions. Magnetic measurements offer high
sensitivity and allow the detection of very subtle metallurgic events.

Applications
The Sigmameter is successfully applied for the determination of ferromagnetic compounds in both research and
development as well as in quality control. It can measure the value of the specific saturation magnetization s of a
material in just a few seconds.

Units and values at 20C


CGS system (EMU CGS) MKS rationalized system
Massm g kg
Magnetic saturation momentm G.cm3 T.m3
Specific saturation magnetization.. s G.cm3.g-1 T.m3.kg-1
Nickel 54.5 68.5 X 10 - 6
Cobalt 160 201 X 10 - 6
Fe 217 275 X 10 - 6
Fe3C 132 166 X 10 - 6
Fe2O3 80 100.5 X 10 - 6
Fe3O4 92 115.5 X 10 - 6
Fe12O19Ba 72 90.5 X 10-6

1 G. cm3g-1 = 4 10-7 T.m3.kg-1 MKS rationalized system

Cemented carbide manufacturing


Cemented carbides are made by a sintering process using powder metallurgy technology. The main components are hard particles (which can be
tungsten carbide, titanium carbide, niobium carbide, tantalum carbide) and a binder which is usually cobalt or nickel. Both these binders are
ferromagnetic compounds.
They must be determined during the manufacturing process to find out whether there are any oxides in the powder before sintering, and for an
indirect determination of the carbon content in sintered cemented carbide.
This analysis is done by comparing the theoretical value with the measured value. Determination of carbon content is the most essential control in
carbide production and the Sigmameter is very useful for this purpose.

Magnet manufacturing
The raw product used in magnet manufacturing is usually a powder. The best method of checking its quality
is to measure its s.
This test is carried out by both the powder supplier and the manufacturer. The s value is given as a
purity criterion. s determination is a standard quality control for all magnets made of ferrite and
cobalt rare earth compounds before and after sintering.
The research and development of new metallic alloy magnets could not be achieved without inves-
rtesy of Ceratizit

tigating the s.

Metallurgy
by cou

- Martensite determination in stainless steels.


- Investigation of the concentration of martensite in stainless steels under different strain rates
- Martensite determination after quenching
- Austenite determination
- Phase diagram investigation
- Ferrite determination in welding material

Other fields of application


- Geology
- Magnetic material control
- Cobalt or nickel determination in special compounds
The examples given are typical applications, but as with all techniques, new ones might be developed in the future.
3

Principle
The sigmameter is designed to measure the specific saturation
magnetization s of a material. This parameter characterizes a
ferromagnetic phase and it is in principle independent of the
structure and shape of the sample. When a ferromagnetic
compound is in a magnetic field, it is magnetized. The value of
its magnetization increases with the field and then reaches a
maximum.
The specific saturation magnetization s is the ratio of
the maximum of the magnetic moment to the mass of
the material. The magnetic moment is determined by
driving a sample out of the magnetic field and
measuring the induced e.m.f. in a coil.
The integral is proportional to the s value of the sample,
provided that it was saturated in the field.
The microprocessor of the reading unit integrates the e.m.f. and
does the required data processing. It calculates the value of
either the s or the content of the ferromagnetic phase.
The value is read on a digital display.

Description
The principle operation of the sigmameter is based on a very
simple electromagnetic property. The magnet box contains a
powerful permanent magnet and a mechanical system to drive a
sample in and out of the magnetic field.
The loading and unloading of the sample is easy and takes
just a few seconds. The sample is slipped into a sample holder, the
shape of which can be modified depending on the type of
sample; if necessary, the holder can be removed rapidly in order to fit
another one.

magnetic circuit
position EXTRACTION position CENTRAGE

measuring coils sample

by cou
rtesy of Ceratizit

magnets poles
jack piston sample holder arm
pneumatic jack

compressed air

pneumatic valve for the jack

The mass of the sample can be fed through an interface from an electronic balance into the microprocessor.
The result is available as a digital signal. When it is fed into the printer, it is automatically printed. The data can also be reviewed
on a PC in Excel format with dedicated Setaram software. Handling is limited to the weighing and loading of
the sample. The sigmameter with its associated balance, is an attractive piece of equipment for quality control. It can be readily
integrated into a production line for on-line control.
4 Specifications
Technical data
Maximum recommended sample dimensions 30 X 20 mm
Air-gap 60 X 25 mm
Air-gap field 800 kA.m-1 / 10000 Oe (1)
Ejector Electro-pneumatic jack
Sensitivity Approx. 1 mg cobalt
Accuracy 1% on full scale
Measuring time About 10 sec. (weighing excluded)
Ambient temperature range +10C to +40C
Electrical Supply 230 V - 50/60 Hz 50 VA
Air Supply 4 bars
Weight 400 kg

(1)
1 Oe = 1/4 kA.m-1

Driving and display unit for all types


Display of s in either
- Gauss cm3.g-1
- Micro Tesla m3.kg-1
- cobalt content in %
by selection on the keyboard of the driving unit.
The result is given on of a 4-digit display.
Specify the type of display required when ordering. The weight of the sample is set by the keyboard
with a resolution of 0.001 g up to 400.000 g. Sample form correction factor can be entered
via the keyboard. Input on the rear panel for remote control.

Specifications are given as indications only and are not contractual - 05/05
On option
1) Digital input and interface to automatically feed the weight of the sample from a balance.
2) Digital output and interface to feed the result into the printer or computer.
3) Upgrading of electronic reading unit of previous Sigmameter models.

Some of our reference users


Acerinox Seco
Ceratizit Stellram
Hartmetall Sumitomo
Kennametal Thyssen Krupp
Nachi Toshiba Tungaloy
Sandvik Widia

SETARAM INSTRUMENTATION SETARAM Inc.


7, rue de lOratoire 7905 Browning Rd, Suite 206
69300 Caluire - France Pennsauken N J 08109-4323 - USA
Phone +33(0)4 72 10 25 25 Phone +1 856 910 9990
Fax +1 856 910 1150
Fax +33(0)4 78 28 63 55
sales@setaram.com / www.setaram.com

A KEP Technologies Company

T E C H N O L O G I E S

You might also like