Connection Design
Connection Design
30
NEW 2L-BRACING
80
2L-70X70X8
30
DETAILS OF BRACING
CONNECTION (DETAIL-A)
STEEL CCOLUMN
40
75
30
75
40
80
2L-70X70X8 mm
30
3
16(5mm)
DETAILS OF BRACING
CONNECTION (DETAIL-B)
________________________________________________________________________________
DEMANDS
Right beam Left beam Column Pu
Description Pu Vu Mu33 Pu Vu Mu33 Pu Vu Brace1 Brace2 Brace3 Brace4 Load
type
[KN] [KN] [KN*m] [KN] [KN] [KN*m] [KN] [KN] [KN] [KN] [KN] [KN]
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 266.89 0.00 0.00 0.00 Design
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
GEOMETRIC CONSIDERATIONS
Dimensions Unit Value Min. value Max. value Sta.
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Directly bolted
DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Gusset
Beam yielding (normal stress) [KN] 1442.77 231.14 DL 0.16 Eq. B-
1,
Appendix B,
REFERENCES
{9} AISC 2005, Design Examples Version 13.0, pp. IIC-26 - IIC-27
CONNECTION CHECK FOR DETAIL-C
16mm GUSSET PLATE
6 - 20mm A325 N BOLT
40
STEEL CCOLUMN 75
30
75
40
80
30
40
75
75
40 2L-70X70X8 mm
30
80
30
3
16(5mm)
DETAILS OF BRACING
CONNECTION (DETAIL-C)
________________________________________________________________________________
DEMANDS
Right beam Left beam Column Pu
Description Pu Vu Mu33 Pu Vu Mu33 Pu Vu Brace1 Brace2 Brace3 Brace4 Load
type
[KN] [KN] [KN*m] [KN] [KN] [KN*m] [KN] [KN] [KN] [KN] [KN] [KN]
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 120.10 0.00 0.00 71.17 Design
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
GEOMETRIC CONSIDERATIONS
Dimensions Unit Value Min. value Max. value Sta.
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Directly bolted
DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Appendix B,
Appendix B,
DG29
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ratio 0.26
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
GEOMETRIC CONSIDERATIONS
Dimensions Unit Value Min. value Max. value Sta.
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Directly bolted
DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio
References
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
REFERENCES
{9} AISC 2005, Design Examples Version 13.0, pp. IIC-26 - IIC-27