TRAC-LOC

Vertical Lock-Seam
Tank Insulation
TM
TRAC-LOC
A Solutions Company
Panel Construction
Tyco Thermal Controls, a division of Tyco Flow
Panels are fabricated by laminating insulation material to a pre-
Control, provides complete heat tracing and formed metal jacket. Panels can be the entire height of the tank
eliminating jacketing penetrations and reducing total installation
heat management solutions to industrial, com-
cost. Panels are manufactured in one continuous piece equal to
mercial and residential markets. Employing the height of the tank, eliminating horizontal joints. Panels can
thousands of people around the world, Tyco be made from one or more industrial insulating materials. Jacket
materials conform to industry standards.
Thermal Controls is the global heating solutions
leader.

Worldwide Approach
Decades of experience and operations in 48
countries around the globe gives Tyco Thermal
Controls the ability to support any project,
anywhere, at anytime. Whether specialized
products or turnkey construction services, Tyco
Thermal Controls provides the solution.

The Tracer Brand


Since 1984, Tracer Industries has been widely
regarded as the premiere provider of turnkey
heat-tracing services and engineered product
solutions in the industrial marketplace. Today,
within Tyco Thermal Controls, the Tracer brand
continues to signify excellence in complete
engineering, design, project execution and
maintenance services of heat management
systems.

Tracer Trac-Loc System Materials


Jacket:
The Trac-Loc system is a double-locking
Aluminum* .024" (0.6 mm)
standing seam insulation panel system that Stainless steel .016" (0.4 mm)
Steel 26 Gauge
delivers structurally superior, maintenance-
Galvalume .024" (0.6 mm)
free, and lower cost insulation than con-
*Jacket material can be coated for corrosive environments and colored for aesthetics.
ventional tank insulation methods. Trac-Loc
is ideal for large, flat-bottomed tanks used Insulation:
Fiberglass K = .24 BTU In/Hr Ft F Tmax = 850F (454C)
for storage of materials that are sensitive Cellular Glass K = .30 BTU In/Hr Ft F Tmax = 900F (482C)
to temperature fluctuations and require a Polyisocyanurate K = .19 BTU In/Hr Ft F Tmax = 250F (121C)
Mineral Wool K = .26 BTU In/Hr Ft F Tmax = 1200F (149C)
covering of insulation and jacketing to Calcium Silicate** K = .34 BTU In/Hr Ft F Tmax = 1200F (149C)
reduce heat loss or gain. The Trac-Loc Expanded Perlite** K = .34 BTU In/Hr Ft F Tmax = 1200F (149C)
Vertical Lock-Seam Tank Insulation system K-Factor based on 100F (38C) mean temperature
See the Engineering Specification for Trac-Loc Panel Systems (H57589) for detailed temperature
is unique in its design, panel construction range information.
**Used for double layer composite insulation applications only
and installation techniques. Trac-Loc is
provided as a complete installed system.
Advanced Interlock Panel System for Tank Insulation
Design
The Trac-Loc advanced interlock panel
system consists of prefabricated panels
of insulating and jacketing material.
These panels, fabricated to the height of
the storage tank, include mating seams
that are mechanically folded together.
This mechanical seam creates a homog-
enous jacket that not only secures the
panels to the storage tank, but also
reduces moisture ingress, has superior
bend resistance, and has inherent
expansion and contraction properties. Trac-Loc clip and panels prior to assembly.

Alignment of Trac-Loc clip and panels.

Double locking of panels creates seal.


Final seam.

Installation
Installing the Trac-Loc tank insulation does not
require conventional scaffolding or horizontal
bands, making the installation cost effective
and maintenance free.

A Trac-Loc clip
secures the panel
to the cable.

A manbasket is used to install and


lock panels together.

A Trac-Loc cable grid is tensioned to


the tank using turnbuckles.
Why Trac-Loc?
The unique construction methods used with
Trac-Loc offer many advantages over conventional
insulation systems.

Cost effective: Eliminating scaffolding results in


lower installed cost and schedule compression.

Superior structure: Continuous 360 interlocking


seams provide rigidity that reduces moisture
ingress and offer superior wind resistance.

Maintenance free: Interlocking panels eliminate


the use of external horizontal bands that require
maintenance over time. Screws are not required,
so jacket penetrations are eliminated.

Repairable: Single panels may be replaced if


damaged.
06/04
H57478

Important: All information, including illustrations, is


believed to be reliable. Users, however, should inde-
pendently evaluate the suitability of each product for
their particular application. Tyco Thermal Controls
Printed in USA

makes no warranties as to the accuracy or complete-


ness of the information, and disclaims any liability
regarding its use. Tyco Thermal Controls' only obliga-
tions are those in the Tyco Thermal Controls Standard
Terms and Conditions of Sale for this product, and in
no case will Tyco Thermal Controls or its distributors
2004 Tyco Thermal Controls LLC

be liable for any incidental, indirect, or consequential


damages arising from the sale, resale, use, or misuse
of the product. Specifications are subject to change
without notice. In addition, Tyco Thermal Controls
reserves the right to make changeswithout notifica-
tion to Buyerto processing or materials that do not
affect compliance with any applicable specification.

Tyco, Tracer and Trac-Loc are trademarks or regis-


tered trademarks of Tyco Thermal Controls LLC or its
affiliates.

Worldwide Headquarters Canada


Tyco Thermal Controls Tyco Thermal Controls
300 Constitution Drive 250 West St.
Menlo Park, CA 94025-1164 Trenton, Ontario
USA Canada K8V 5S2
Tel (800) 545-6258 Tel (800) 545-6258
Fax (800) 596-5004 Fax (800) 527-5703
E-mail: info@tycothermal.com
www.tycothermal.com