Simulator PDF
Simulator PDF
Simulator PDF
010-8931062
This hand-held device simulates both heart and breath sounds and allows the determination of these by
plugging in one of 7 different menus (see W49401, W49402, W49403, W49404, W49405, W49406 and W49436),
each containing 16 different sounds*. The Heart and Breath Sounds Simulator unit includes two external sounders
with which students can auscultate the sounds with a stethoscope. Linking additional stethoscope sounders (see
W49430), up to 15 students can auscultate at the same time. A Loud Speaker may also be connected. Additionally,
the unit has a volume control and two LEDs that illuminate during systole (heart menu) and expiration (breath
menu).
* All data used in the menus are actual patient sounds. Sounds of the same name are from different patients in
different menus to show appearance variations.
NORAIDAH KASIRAN@DASUKI
010-8931062
1. Tracheal 9. Cavernous
2. Vesicular 10. Crackles, fine
3. Broncho-Vesicular 11. Crackles, rhonchi
4. Bronchial 12. Crackles, course
5. Wheezes 13. Pulmonmy edema
6. Monophonic wheeze 14. Infant
7. Pleural friction rub 15. Egophony
8. Stridor 16. Pectoriloquy
NORAIDAH KASIRAN@DASUKI
010-8931062
In addition to the simulation of heart and breath sounds, this tutor allows also the determination of arrhythmias. A
perfect tool for Nursing schools, EMS Education programs, medical schools or other healthcare settings where rhythm and
sound recognition is critical. 10 different menus for arrhythmia and 11 for heart & breath sounds can be plugged into the tutor
(see below for complete listing), each containing 16 different sounds*. Arrhythmias may be viewed on any ECG-monitor by
connecting the three snap-on lead patient wires. (If no ECG-monitor is available, please see W49429.) The unit includes two
built-in sounders and two external sounders by which students can auscultate the sounds with a stethoscope. Linking
additional sounders (see W49430), up to 50 students can auscultate at the same time. Also a speaker may be connected.
Additionally, the unit has a volume control and two LEDs that illuminate during systole (heart menu) and expiration (breath
menu) as well as an illuminated display showing the example currently playing. The unit comes with a 12 Volt adapter.
* All data used in the menus are actual patient sounds. Arrhythmias and sounds of the same name are from different patients
in different menus to show appearance variations.
NORAIDAH KASIRAN@DASUKI
010-8931062
9. 4 LICS control