Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Fencing & Gates Typical Details Standard Drawing: Section A - A Option 1 Door

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Intermediate Post 3 Strands Galvanised Gate Post DN 80 Top Diagonal Brace DN 20 Gate Post DN 80 Top Diagonal Brace DN 20

DN 40 < 48.3 O.D. > Barbed Wire 88.9 O.D. - 4.0 Thickness 26.9 O.D. - 2.3 Thickness 60.3 O.D. - 3.6 Thickness 26.9 O.D. - 2.3 Thickness
with Galv. Steel Cap with Galv. Steel Cap Gate Outer Frame DN 32 with Galv. Steel Cap
42.4 O.D. - 2.3 Thickness
50

450

Bracing Strut
DN 32 < 42.4 O.D. >

300 300
Hinch Clamp
Heavy Striker
Support
Plate Inner Frame DN 25 Inner Frame DN 20 Gate with
Cable
33.7 O.D. - 2.6 Thickness 26.9 O.D. - 2.3 Thickness Locable Shoot Bolt

CHAIN LINK
2100 }
FABRIC
20 mm
Max

Tumbuckle
Chain Link Tumbuckle Welded to Gate Frame Gate Outer Frame DN 32
Length Suitable for 33.7 O.D. - 2.6 Thickness
Padlocking
Support Cable

INTERMEDIATE Diagonal Bracing


PANEL Cable

DN12 Reinforcement Bar 200


600 Long Through Drilled Holes

DOUBLE GATE DOUBLE GATE SINGLE GATE


BRACED PANEL 1000 Galvanised Plain Bar BRACED PANEL 750 BRACED PANEL
250 Drop Bolts:
Provide DN 25 Medium x 150
Long Keepers Set in 300 x 250 x 350 Min
Deep Concrete Footing for Closed Position & Post Foundation Post Foundation
250 Dia.
150 Dia. x 350 Min. Deep Concrete Footing
for Open Position

3000 Max 6000 Opening


250 Dia.
300 Dia
2000 Opening
SECTION A - A
OPTION 1 DOOR

NOTES:
Diagonal Bracing
1. ALL CHAIN LINK MESH SHALL COMPLY WITH
Cable
AS1725-2003 (OR LATER).

2. ALL CHAIN LINK MESH SHALL BE:


PITCH - 50MM PITCH
WIRE - 2.5MM DIA
SELVEDGE - KNUCKLE - KNUCKLE (KK)
PLAN
3. CHAIN LINK MESH WIRE SHALL BE EITHER:
a. HEAVY DUTY (HD) GALVANISED (CLASS W10) OR
b. BLACK, POLYVINYL COATED (PVC) AS DIRECTED
AS DIRECTED ON THE DRAWING OR THE BOQ.

4. FOUNDATION CONCRETE SHALL BE ORDINARY


Turnbuckle
(17.5MPa).

5. THE FENCING CONTRACTOR SHALL PREPARE A


DETAILED FENCING PLAN SHOWING:
THE LOCATION OF ALL BRACING PANELS
GATE LAYOUTS AND OTHER NON STANDARD
DETAILS,
FOR THE APPROVAL OF SWA BEFORE COMMENCING
INSTALLATION WORK.
3000

CORNER BRACED
PANEL

3000 3000 3000

A A

BY. DATE. REV. DESCRIPTIONS. DATE. APRVD. DRAWING TITLE : PROJECT TITLE : SIZE CONTRACT NUMBER : REVISION
DESIGNED : P.R _ _ /_ _ /_ _ _ _ _ _ /_ _ /_ _ _ _ __ SAMOA WATER AUTHORITY
A3 2
DRAWN : T.A _ _ /_ _ /_ _ _ _ _ _ /_ _ /_ _ _ _ __
FENCING & GATES Level 2 TATTE
DSGN CHECKED : P.R _ _ /_ _ /_ _ _ _ _ _ /_ _ /_ _ _ _ __ STANDARD DRAWING Building

DWG CHECKED : P.R _ _ /_ _ /_ _ _ _ _ _ /_ _ /_ _ _ _ __


TYPICAL DETAILS Apia, Sogi
Ph: +685 20409
SCALE : DRAWING NUMBER :

Fax: +685 21298 N.T.S W - 026


APPROVED : P.R _ _ /_ _ /_ _ _ _ _ _ /_ _ /_ _ _ _ __