QSX15 Series 60 HZ
QSX15 Series 60 HZ
QSX15 Series 60 HZ
Generation
Diesel Powered
Generating Sets
410 kW - 500 kW 60 Hz
QSX15 Series Engine
ST OF CERTIFICATION
I
ERED BODIES
systems with provision for base fuel Low Emissions
tank and other accessories
Integral cooling systems which Quality Assurance
Registered Firm Certicate Number FM509 in accordance with:
deliver low NOx, CO, HC, PM and BS EN ISO 9001
Cummins Engine SO2 exhaust emissions Quality Assurance Schedule 3420/1
Heavy duty 4 cycle water cooled
engine One
Sourc
e
ernator
Electronic governor control Alt
Co
Engine
Cooling System
ntrols
e r a ti n g S e
t
Ready Filled
One
Every set comes lled with lube oil Name
60 Hz Ratings
Model Prime Model Standby Engine
Prime kW (kVA) Standby kW (kVA) Model
410 DFEJ 410 (513) 450 DFEJ 450 (563) QSX15G9
455 DFEK 455 (569) 500 DFEK 500 (625) QSX15G9
frequency. Voltage, current and kW are Digital full authority electronic engine Digital Synchroscope
scaled in % of nominal values, and all controls for Cummins HPI-PT fuel system, Engine Starting Battery Voltage
values are color coded to indicate normal, including engine monitoring and Engine Lube Oil Pressure
warning, and abnormal operating protection, and governing. These Engine Coolant Temperature
conditions functions are integrated with voltage Engine Coolant Pressure
Single membrane front panel with regulation, synchronizing, and load Engine Fuel Rail Temperature and
enclosure rated NEMA 3R/IP53 sharing controls, including import/export Pressure
controls for paralleling with an innite Engine Fuel Input and Output
(utility/mains) bus Temperature
Control Functions AmpSentry Protection for true Intake Manifold Temperature and
Isochronous governing alternator overcurrent protection Pressure
3-phase sensing voltage regulation with Analog and Digital AC Output Metering Engine Fuel Consumption
single and three phase fault current Battery Monitoring System to sense and Ambient Air Pressure
regulation warn against a weak battery condition Crankcase Blowby Flow
AC output protection including over/under Digital Alarm and Status Message Display Aftercooler Inlet Coolant Temperature
voltage, over/under frequency, Generator set Monitoring: Displays status Engine Exhaust Temperature (optional)
overcurrent, short circuit, and over load of all critical engine and alternator
(kW) generator set functions
Smart Starting Control System: Integrated Internal Control Functions
Engine control and monitoring system
with displays for oil pressure, oil fuel ramping to limit black smoke and
temperature, engine coolant temperature, frequency overshoot, in addition to General Functions
engine speed, battery voltage and other optimized cold weather starting
Advanced Serviceability using InPower, a
Emergency Start Mode
values Non-Emergency Start Mode
Generator set protection system including PC-based software service tool
PowerCommand Communications
Sleep Mode
AC output protection alarms, engine Data Logging
pressure, temperature warning, Network Capability (optional)
Fault Simulation Mode
Shutdown functions, low coolant Built In Test
temperature, low coolant level, low fuel Control Switches and First Start Sensor System
level, failure to crank, failure to start and Functions Synchronizer
overspeed Load Demand Mode
Operator adjustments for time delay, OFF/MANUAL/AUTO Mode Control
Switch
Load Govern Mode
start/stop, engine speed, and overspeed Manual (Semi-Automatic) Parallel Mode
Technician setup menu MANUAL RUN/STOP Control Switch and
Status and data display functions Indicating LED
including engine operating hours, kW EXERCISE Control Switch and Indicating Engine Control
hour productions, AC metering functions LED Engine Starting
and fault history PANEL LAMP/LAMP TEST Control Cycle Cranking
Switch Programmable Idle Speed Control
EMERGENCY STOP Control Switch Time Delay Start and Stop (cooldown)
Control Options Graphical Operator Panel
Alternator temperature alarms Engine Governing
Audible alarm module Graphical Display Panel
Automatic mains failure control
Isochronous Governing
Generator Set Hardware Data Droop Governing
Control anti-condensation heater Data Logs
Digital paralleling controls
Temperature Dynamics
Adjustment History Idle Mode
Echelon LonWorks interface Fault History
Generator running relay contacts
Isochronous (kW) Load Sharing Control
Load Prole Data
Key-type mode control switch Generator Set Output Voltage
Generator Set Output Current
Ratings
Standby
Applicable for supplying emergency power for the duration of normal power interruption. No sustained overload capability is available for this rating.
Nominally Rated (equivalent to fuel stop power in accordance with ISO 3046).
Prime
Applicable for supplying power in lieu of commercially purchased power. Prime power is the maximum power available at a variable load for an
unlimted number of hours. A 10% overload capability is available for limited time. Nominally rated.