Fieldbus Electronics

G3 | Communication Node and I/O

www.asco.com
Table of Contents
G3 Fieldbus Electronics and I/O
Features and Benefits 2
G3 Platform Distribution Options 4
DeviceNet 6
Ethernet 7

PROFIBUS DP 8

PROFINET 9

CANopen 10
DeviceLogix 11

Ethernet POWERLINK 12

EtherCAT 13
EtherNet/IP DLR 14
CC-Link IE Field 15
I/O Modules - Digital Inputs - Terminal Strip Modules & Valve Side Output Module 16
I/O Modules - Digital I/O 5-Pin M12 Modules 17
I/O Modules - Analog I/O (16 bit resolution) 17
Input Modules - RTD & NAMUR IS 18
Sub-Bus Modules 19
Miscellaneous Modules & Accessories 21
Dimensional Drawing - G3 Fieldbus Communication Assembly 23
How to Configure & Order G3 Electronics 25
How to Order Sub-Bus Valve Manifolds 26
How to Order G3 Assembly Kit & G3 Electronics 27
How to Order Complete G3 Manifold Assembly 28
501 Series Technical Data 29
501 Series How to Order- Valves & Regulators 30
503 Series Technical Data 31
503 Series How to Order- Valves & Regulators 32
2002 R2 & 02 Series Technical Data 33
How to Order 2002 R2 & 02 Series - Valves 34
2005 Series Technical Data 35
How to Order 2005 Series - Valves & Regulators 36
2012 Series Technical Data 37
How to Order 2012 Series - Valves & Regulators 38
2035 Series Technical Data 39
How to Order 2035 Series - Valves & Regulators 40
ISO 15407-2 18mm Series Technical Data 41
How to Order ISO 15407-2 18mm Series - Valves & Regulators 42
ISO 15407-2 26mm Series Technical Data 43
How to Order ISO 15407-2 26mm Series - Valves & Regulators 44
ISO 5599/2 Series Technical Data 45
How to Order ISO 5599/2 Series - Valves & Regulators 46
Cables & Connectors 47

DeviceNet/CANopen Cables & Connectors 50

PROFINET Cables & Connectors 51

Ethernet POWERLINK Cables & Connectors 52

PROFIBUS DP Cables & Connectors 53

EtherCAT Cables & Connectors 54
Ethernet Cables & Connectors 55
CC-Link IE Field Cables & Connectors 56
I/O Cables & Connectors 57
Sub-Bus Cables & Connectors 60
G3
Electronics

G3 Fieldbus - Electronics Made Easy!


Innovative Graphic Display is used for easy commissioning, visual
status & diagnostics.

Commissioning Capabilities
Set network address (including Shorted and open load
IP & Subnet mask for Ethernet) detection
Set baud rate Shorted sensor/cable detection
Set auto or manual I/O sizes Low & missing power detection Graphic Display for Auto Recovery Module
Set fault/idle output states Missing module detection Configuration & Diagnostics
Set brightness Self-test activation
Set factory defaults Log of network errors
Visual diagnostics Distribution errors

G3 Fieldbus Communications Electronics


Why use Numatics Fieldbus communication electronics?
Modular Reality... Highly Distributable Easy, Robust Connections
No internal wiring simplifies assembly
SPEEDCON M12 connector technology allows for fast and
efficient turn I/O connector attachment
Power connector allows output power to be removed while Supported Protocols
inputs and communication are left active DeviceNet CANopen
IP65 protection DeviceNet w/ PROFINET
Up to 1200 Input/1200 Output capability with one QuickConnect
Ethernet POWERLINK
communication node! (Present physical I/O combinations DeviceNet w/
allows 1200 I/544 O) EtherCAT
DeviceLogix
32 valve solenoids per manifold, up to 17 manifolds per EtherNet/IP DLR
Ethernet w/QuickConnect
communication node!
PROFIBUS DP
One node supports 16 I/O modules Analog I/O, Digital I/O CC-Link IE Field
(NPN & PNP) and Specialty
Innovative clip design allows easy module removal/
replacement without dismantling manifold
Auto Recovery Module (ARM) protects configuration
information during a critical failure. Allows configuration
information to be saved and reloaded to replacement module
automatically

*Numatics I/O with


SPEEDCON technology
*
1/2 turn for faster I/O connections
Backwards compatible with standard
M12 cables/connectors
Meets the same IP/NEMA standards
as M12/Micro cables/connectors
Same cost as standard M12/Micro
cables/connectors
DeviceNet and QuickConnect are trademarks of ODVA.
See page 56 for cables with DeviceLogix is a trademark of Rockwell Automation, Inc.
SPEEDCON connector technology PROFIBUS and PROFINET are registered trademarks of Profibus Nutzerorganisation e.V.
CANopen is a registered Community trademark of CAN in Automation e.V.
Ethernet POWERLINK is a registered trademark of Bernecker + Rainer Industrie Elektronik Ges.m.b.H.
CC-Link is a registered trademark and CC-Link IE Field is a trademark of the CC-Link Partner Association.

2
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

G3 Electronics Modularity
Discrete I/O
The G3 Series product line is a completely modular system. All of the G3 electronic modules plug together, via
mechanical clips, allowing easy assembly and field changes. This makes the system highly distributable. Additional
flexibility is incorporated because the same modules can be used in either centralized or distributed applications.
The G3 electronics interfaces with the highly modular Numatics 500 Series, generation 2000 Series, ISO 5599/2
and ISO 15407-2 Series valve lines to further enhance the modularity and flexibility of the entire system.

Sub-Bus Out or
Terminator Module
Jumper Clips

I/O Labels

Auto Recovery Module (ARM)

I/O Modules-
Analog or Digital,
NPN or PNP

Communication
Module (Node)

Valve Manifold Assembly


501, 502, 503, 2002, 2005,
2012, 2035, ISO15407-2 &
ISO 5599/2 Series Valves

DIN Rail Mounting Option

3
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

G3 Platform Distribution Options


Easy, Cost Effective Solutions for Digital I/O and Valve Automation using G3 Electronics.

Main Fieldbus Manifold

Sub-Bus

Sub-Bus In
Sub-Bus Out
24 VDC Power
Supply (optional)

I/O Only
Sub Manifold Sub Manifold
with Valves with I/O & Valves

Sub-Bus Out

24 VDC
Power
Supply
Sub-Bus
24 VDC
Power
Supply

Unique distribution system allows system efficiency by allowing the same modules to be used in either
centralized or distributed applications
Distribution options include:
Inputs OR Outputs
Inputs AND Outputs
Valves with Inputs AND Outputs
Valves with Inputs OR Outputs
Valves Only
Maximum Sub-Bus length not to exceed 30 meters. Maximum Sub-Bus cable current not to exceed 4 amps or
excessive cable voltage drops per segment. Auxiliary power connections available for currents above 4 amps.
Consult factory for possible deviations

4
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

G3 Platform Distribution Options


The G3 platform is flexible to the point that there are a virtually infinite number of I/O distribution options using the few
basic G3 modules. The following basic rules should be followed in the configuration of your control architecture.

Typical Main Fieldbus Manifold

Valve Side Comm. Module

Up to a total of 32 valve solenoids can be driven


in a manifold assembly integrated into the Main
Fieldbus Manifold. This can be any number of single
or double solenoid valves with a total number of
solenoids not to exceed 32
A valve side output module is available. If a valve
side output module is used, 16 outputs are allocated
to the solenoids in the integral manifold and 16 are
allocated to the output module in the manifold I/O Side Valve Side

Comm. Module
I/O Side Distribution
A total of 16 modules can be integrated into the
network and controlled by the main fieldbus
communication module (node)
Modules include analog and digital I/O modules
providing addressing capacity for up to 1200
Inputs/1200 Outputs per node
Unique distribution system allows system efficiency
by allowing the same modules to be used in either I/O Side
centralized or distributed applications
Distribution options include Inputs only, Outputs only,
I/O only, valves with Inputs, valves with Outputs and
valves with I/O
Configuration can include up to 16 of the following
modules: Comm. Module

Digital I/O modules


Sub-Bus valve modules 16 Modules can be
Analog I/O modules supported on this side
of the comm. module

5
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

DeviceNet
DeviceNet is an open bus fieldbus communication system
developed by Allen-Bradley based on Controller Area Network
(CAN) technology. The governing body for DeviceNet is the
Open DeviceNet Vendors Association (ODVA). The ODVA
controls the DeviceNet specification and oversees product
conformance testing.
Numatics G3 nodes for DeviceNet have an integrated
graphic display and are capable of addressing combinations
of up to 1200 outputs and 1200 inputs.
They have been tested and approved for conformance by the
ODVA.
More information about DeviceNet and the ODVA can be
obtained from the following website: www.odva.org. Replacement Part
Description
Number
DeviceNet communications
240-180
module (node)
Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10% 0.070 Amps
BUS Power 11-25 VDC 0.025 Amps
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps Maximum
Power Connector Single key 4 pin 7/8" MINI type (male)
Communication Connector Single key 5 pin 7/8" MINI type (male)
LEDs Module Status and Network Status

Operating Data
Temperature Range (ambient) -23 C to 50 C- (10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Display used for setting Node Address, Baud Rate, Fault/Idle Actions, DeviceNet w/QuickConnect and
Graphic Display
all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 125K Baud, 250K Baud, 500K Baud, with Auto-Baud detection
Supported Connection Type Polled, Cyclic, Change of State (COS) and combination Message Capability
Bus Connector Single key 5 pin 7/8" MINI type (male)
Diagnostics Power, short, open load conditions and module health are monitored
Special Features Supports Auto-Device Replacement (ADR) and fail-safe device settings

Weight
DeviceNet Communications Module 252g/8.9 oz.
6
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Ethernet (EtherNet/IP & Modbus TCP/IP)


Ethernet used throughout the world to network millions of PCs
has now evolved into a viable industrial network. Ethernet is
an open architecture high-level communication network that
meets the demands of todays industrial applications requiring
high-speed (10/100 Mbit/s), high-throughput and flexibility.
Additionally, Ethernet technology can integrate an on-board
web server, which can make the node readily accessible to
any standard web browser for configuration, testing and even
retrieval of technical documentation.
Numatics G3 nodes for Ethernet have an integrated graphic
display and are capable of addressing combinations of up to
1200 outputs and 1200 inputs.
The G3 EtherNet/IP nodes have been tested and approved
for conformance by the ODVA. Replacement Part
Description
Number
More information about EtherNet/IP and the ODVA can be EtherNet/IP communications
obtained from the following website: www.odva.org. 240-181
module (node)
Modbus TCP/IP communications
240-292
module (node)
Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10% .091 Amps
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps maximum
Power Connector Single key 4 pin 7/8" MINI type (male)
Communication Connector D-coded 4 pin M12 type (female)
LEDs Module Status, Network Status and Activity/Link

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Display used for setting IP Address, Subnet mask, Fault/Idle Actions, DHCP/BootP and all other system
Graphic Display
settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 10 Mbit/100 Mbit
Bus Connector D-coded 5 pin M12 type (female)
Diagnostics Power, short, open load conditions and module health are monitored
Special Features Integrated web server, fail-safe device settings, HTTP, FTP, and UNICAST (for EtherNet/IP)

Weight
Ethernet Communications Module 255g/9 oz.
7
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

PROFIBUS DP
PROFIBUS DP is a vendor-independent, open fieldbus protocol
designed for communication between automation control
systems and distributed I/O at the device level.
Numatics G3 nodes for PROFIBUS DP have an integrated
graphic display and are capable of addressing combinations of
up to 1200 outputs and 1200 inputs.
The G3 nodes for PROFIBUS DP have been designed and
tested to conform to the PROFIBUS standard EN50170.
Certification has been done by the PROFIBUS Interface Center
(PIC) according to the guidelines determined by the PROFIBUS
Trade Organization (PTO). The certification process ensures
interoperability for all PROFIBUS devices.
More information regarding PROFIBUS can be obtained from Replacement Part
the following website: www.profibus.com. Description
Number
PROFIBUS DP communications
240-239
module (node)

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10% .094 Amps
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps Maximum
Power Connector Single key 5 pin 7/8 MINI type (male)
Communication Connector Single reverse key (B-Coded) 5 pin M12 type (1 male and 1 female)
LEDs Module Status and Network Status

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting Node Address, Baud Rate, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event
ARM
of total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 125K Baud, 250K Baud, 500K Baud, with Auto-Baud detection
Bus Connector Single key 5 pin 7/8" MINI type (male)
Diagnostics Power, short, open load conditions and module health are monitored
Special Features Supports Auto-Device Replacement (ADR) and fail-safe device settings

Weight
PROFIBUS DP Communications Module 227g/8 oz.

8
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

PROFINET
PROFINET is the innovative open standard for Industrial
Ethernet, developed by Siemens and the PROFIBUS User
Organization (PNO). PROFINET complies to IEC 61158 and IEC
61784 standards. PROFINET products are certified by the PNO
user organization, guaranteeing worldwide compatibility.
Numatics G3 nodes for PROFINET IO (PROFINET RT) have
an integrated graphic display and are capable of addressing
combinations of up to 1200 outputs and 1200 inputs.
PROFINET is based on Ethernet and uses TCP/IP and IT
standards and complements them with specific protocols and
mechanisms to achieve Real Time performance.
More information regarding PROFINET can be obtained from
the following website: www.profibus.com. Replacement Part
Description
Number
PROFINET communications
240-240
module (node)

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10%
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps Maximum
Power Connector Single key 5 pin 7/8 MINI type (male)
Communication Connector Two D-coded 4 pin M12 type (female)
LEDs Module Status, Network Status and Activity/Link

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting IP Address, Subnet Mask, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 10 Mbit/100 Mbit
Bus Connector Two D-coded 4 pin M12 type (2-Female)
Diagnostics Power, short, open load conditions and module health and configuration are monitored
Special Features Integrated web server, Integrated 2 port switch, fail-safe device settings, and FSU

Weight
PROFINET Communications Module 227g/8 oz.

9
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

CANopen
CANopen is an open protocol based on Controller Area
Network (CAN). It was designed for motion-oriented machine
control networks but has migrated to various industrial
applications. CAN in Automation (CIA) is the international
users and manufacturers organization that develops and
supports CAN-based protocols. Numatics G3 nodes for
CANopen have an integrated graphic display and are
capable of addressing combinations of up to 1200 outputs
and 1200 inputs.
More information regarding this organization can be found at:
www.can-cia.org.

Replacement Part
Description
Number
CANopen communications
240-291
module (node)

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10% 0.070 Amps
BUS Power 11-25 VDC 0.025 Amps
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps maximum
Power Connector Single key 4 pin 7/8 MINI type (male)
Communication Connector Single key 5 pin 7/8 MINI type (male)
LEDs Module Status and Network Status

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting Node Address, Baud Rate, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event
ARM
of total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 125K Baud, 250K Baud, 500K Baud, 1M Baud
Bus Connector Single key 5 pin 7/8 MINI type (male)
Diagnostics Power, short, open load conditions and module health are monitored and fail-safe device settings

Weight
CANopen Communications Module 252g/8.9 oz.

10
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

DeviceLogix
DeviceLogix is a Rockwell Automation technology that allows a DeviceNet node to be
programmed to execute a sequence independently from the control for the main PLC/
IPC. A DeviceLogix enabled DeviceNet node can be used in conjunction
with a standard DeviceNet network, providing simple distributed control
functionality. Additionally it can also be used in a standalone application,
without a network connection or PLC/IPC, to sequence pneumatic valves
and control I/O. Numatics has integrated this licensed technology into
its DeviceNet compatible valve manifold series, which combine the
functionality of a modular pneumatic valve system with integrated I/O.
Programming of the DeviceLogix enabled node is done using the
industry standard DeviceNet commissioning software tool RSNetWorx
for DeviceNet from Rockwell Automation. The programming software features
an easily understandable graphics environment where the users can simply drag
and drop logic function blocks (i.e. AND, NAND, OR, NOR, XOR,
XNOR, RS LATCHES, COUNTERS and TIMERS) onto a page and Replacement Part
interconnect them to develop the required sequence, or ladder Description
Number
logic programming can be used to develop a sequence. The
DeviceLogix communications
programmed sequence is downloaded to the node via standard 240-293
module (node)
DeviceNet communication connection, thus multiple nodes can
be programmed on the same network.

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10% 0.070 Amps
BUS Power 11-25 VDC 0.025 Amps
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps Maximum
Power Connector Single key 4 pin 7/8 MINI type (male)
Communication Connector Single key 5 pin 7/8 MINI type (male)
LEDs Module Status and Network Status

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Communication Module Display used for setting Node Address, Baud Rate, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure including embedded DeviceLogix logic instructions
Maximum Valve-Solenoid Outputs 32

Network Data
Supported Baud Rates 125K Baud, 250K Baud, 500K Baud, with Auto-Baud detection
Supported Connection Type Polled, Cyclic, Change of State (COS) and combination Message Capability
Bus Connector Single key 5 pin 7/8 MINI type (male)
Diagnostics Power, short, open load conditions and module health are monitored and fail-safe device settings
Special Features Supports function block diagram and ladder logic programming

Weight
DeviceLogix Communications Module 252g/8.9 oz.
11
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Ethernet POWERLINK

Ethernet POWERLINK is an open fieldbus


protocol designed by B&R for communication
between automation control systems and distributed I/O at the
device level.
Numatics' G3 Ethernet POWERLINK nodes have an integrated
graphic display and are capable of addressing combinations of
up to 1200 outputs and 1200 inputs.
The G3 Ethernet POWERLINK nodes have been designed and
tested to conform to the Ethernet POWERLINK specifications
available at EPSG group (Ethernet Powerlink Standardization
Group). The certification process ensures interoperability for all
Ethernet POWERLINK devices and compatible with B&R systems.
More information regarding Ethernet POWERLINK can be Replacement Part
obtained from the following website: Description
Number
www.ethernet-powerlink.org. POWERLINK
POWERLINKcommunications
communications
240-309
module (node)
module (node)
Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10%
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps maximum
Power Connector Single key 5 pin 7/8 MINI type (male)
Communication Connector Two D-coded 4 pin M12 type (female)
LEDs Module Status, Network Status and Activity/Link

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting IP Address, Subnet Mask, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 10 Mbit/100 Mbit
Bus Connector Two D-coded 4 pin M12 type (2-Female)
Diagnostics Power, short, open load conditions and module health and configuration are monitored
Special Features Integrated web server, Integrated 2 port switch and fail-safe device settings

Weight
POWERLINK Communications Module 227g/8 oz.

12
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

EtherCAT
EtherCAT is an open ethernet-based fieldbus protocol
developed by Beckhoff. EtherCAT sets new standards for
real-time performance and topology flexibility with short
data update/cycle times and low communication jitter.
Numatics G3 EtherCAT node has an integrated graphic
display for simplified commissioning and diagnostics. It is
capable of addressing combinations of up to 1200 outputs
and 1200 inputs.
The G3 nodes for EtherCAT have been designed and
tested to conform with EtherCAT specifications set forth
by the ETG.
More information regarding EtherCAT can be obtained
from the following website: www.ethercat.org. Replacement Part
Description
Number
EtherCAT communications
240-310
module (node)
Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10%
8 Amps Maximum
Valves and Discrete I/O 24 VDC +/- 10%
Power Connector Single key 5 pin 7/8 MINI type (male)
Communication Connector Two D-coded 4 pin M12 type (female)
LEDs Module Status, Network Status and Activity /Link

Operating Data
Temperature Range -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC 60068-2-6
Moisture IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting IP address, Subnet Mask, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system settings in the event of
ARM
total or partial system failure
Maximum Valve Solenoid Outputs 32
Maximum Sub-Bus I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 10 Mbit/100 Mbit
Bus Connector Two D-coded 4 pin M12 type (female)
Diagnostics Power, short, open load conditions and module health and configuration are monitored
Special Features Integrated web server, fail-safe device settings

Weight
EtherCAT Communications Module 227g /8 oz.

13
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

EtherNet/IP DLR
EtherNet/IP used throughout the world to network millions of PCs has now evolved
into a viable industry network. EtherNet/IP is an open architecture high-level
communication network that meets the demands of todays industrial applications
requiring high-speed (10/100 Mbit/s), high-throughput and flexibility.
Additionally, EtherNet/IP technology can integrate an on-board web
server, which can make the node readily accessible to any standard
web browser for configuration, testing and even retrieval of technical
documentation.
Numatics G3 EtherNet/IP DLR (Device Level Ring) node with
integrated display has an embedded switch which allows the unit to
be used in simplified networks with linear topology configurations (daisy
chain). This technology alleviates the need for an external Ethernet switch
device in a single subnet configuration. Additionally, the DLR compatibility allows
the node to be used in a fault tolerant ring network, when using appropriate EtherNet/
IP DLR scanners. DLR configuration allows communication
Replacement Part
recovery from a single point failure on the network ring (e.g. failed Description
Number
network connection or cable).
EtherNet/IP DLR communications
Numatics G3 EtherNet/IP nodes are capable of addressing 240-325
module (node)
combinations of up to 1200 outputs and 1200 inputs.
The G3 EtherNet/IP nodes have been tested and approved for conformance by the ODVA.
More information about EtherNet/IP and the ODVA can be obtained from the following website: www.odva.org.

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10%
8 Amps Maximum
Valves and Discrete I/O 24 VDC +/- 10%
Power Connector Single key 4 pin 7/8 MINI type (male)
Communication Connector Two D-coded 4 pin M12 type (female)
LEDs Module Status, Network Status and Activity/Link

Operating Data
Temperature Range -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC 60068-2-6
Moisture IP65, (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting IP address, Subnet Mask, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system settings in the event of
ARM
total or partial system failure
Maximum Valve Solenoid Outputs 32
Maximum Sub-Bus I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 10 Mbit/100 Mbit
Bus Connector Two D-coded 4 pin M12 type (female)
Diagnostics Power, short, open load conditions and module health and configuration are monitored
Embedded two port switch, Device Level Ring (DLR) compatibility, Linear network topology, QuickConnect
Special Features
capability, fail-safe device settings, integrated web server, HTTP, TFTP, UNICAST

Weight
EtherNet/IP DLR Communications Module 227g/8 oz.
14
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

CC-Link IE Field
CC-Link IE Field is an open standard 1 Gbps Ethernet
Manufacturing network that enables seamless data
communication from the plant-level enterprise network to the
production floor network. The CC-Link Partner Association
(CLPA) oversees and manages CC-Link specifications.
Numatics G3 nodes for CC-Link IE Field have an integrated
graphic display and are capable of addressing combinations of
up to 1200 outputs and 1200 inputs.
CC-Link IE Field is based on 1 Gbps Ethernet standards
and complements them with specific protocols and
mechanisms to achieve real time performance.
More information regarding CC-Link IE Field can be obtained
from the following website: www.CCLinkAmerica.org Replacement Part
Description
Number
CC-Link IE Field
240-362
communications module (node)

Technical Data
Electrical Data Voltage Current
Node Power at Max. Brightness 24 VDC +/- 10%
Valves & Discrete I/O 24 VDC +/- 10% 8 Amps Maximum
Power Connector Single key 5 pin 7/8 MINI type (male)
Communication Connector Two X-coded 8 pin M12 type (female)
LEDs Run, ERR, Link, D Link, L.ERR, L.ER

Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display Display used for setting Node Number, Network Number, Fault/Idle Actions, and all other system settings
(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
ARM
total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates 1 Gbps
Bus Connector Two D-coded 8 pin M12 type (2-Female)
Diagnostics Power, short, open load conditions and module health and configuration are monitored
Special Features Integrated 2 port switch, fail-safe device settings

Weight
CC-Link IE Field Communications Module 269g/9.5 oz.

15
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

I/O Modules
Digital Inputs - Terminal Strip Modules
Description Part Number
16 PNP Inputs 240-203
16 NPN Inputs 240-204
8 PNP Inputs 240-316
16 PNP outputs 240-330

Technical Data
Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
Wire Range 12 to 24 AWG
Strip Length 7mm
Tightening Torque 0.5 Nm
Ingress Protection IP20

Spare Parts
Replacement Terminal Strip (I/O 0-7) 140-1073
Replacement Terminal Strip (I/O 8-15) 140-1074
Keying Element for terminal strip 140-1076
Keying Element for Module 140-1077

Weight
Input Module 292g/10.3 oz.

16
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

I/O Modules
Digital I/O 5-pin M12 Modules
Description Part Number
Inputs
8 PNP Inputs 240-206
8 NPN Inputs 240-210
16 PNP Inputs 240-205
16 NPN Inputs 240-209
Outputs
8 PNP Outputs 240-208
8 PNP High Current
240-300
Outputs (Fig. A Only)
16 PNP Outputs 240-207
Inputs and Outputs
8 PNP Inputs and
240-211
8 PNP Outputs

Figure A
Analog I/O with settable high and low alarms
5-pin M12 Modules
Description Signal Type Part Number
Inputs
4 Analog Inputs 0-10 VDC 240-212
4 Analog Inputs 4-20 mA 240-214
Inputs and Outputs
2 Analog Inputs & 2 Analog Outputs 0-10VDC 240-213
2 Analog Inputs & 2 Analog Outputs 4-20 mA 240-215
2 Analog Inputs & 2 Analog Outputs
0-10 VDC 240-307
High Current (Figure A Only)
4 Analog Inputs & 4 Analog Outputs
4-20 mA 240-363
High Current (Figure A Only)

Technical Data
Operating Data
Temperature Range (ambient) -23 C to 50 C (-10 F to 115 F)
Humidity 95% relative humidity, non-condensing
Vibration/Shock IEC 60068-2-27, IEC60068-2-6
IP65 (with appropriate assembly and
Ingress Protection
termination)
M12 4 Pin Female, Speedcon
Connector
(Compatible with 5 Pin)
Resolution 16 bit Dust Cover -
M12 Male 230-647
Weight
I/O Module-Analog 244g/8.6 oz.
I/O Module-Digital 274g/9.7 oz.

17
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

G3 RTD Temperature Module 240-311


The RTD module is for use with RTD (Resistive Temperature Detectors), supporting
up to four RTD devices simultaneously. The module supports various RTD types
including: Pt100, Pt200, Pt500, Pt1000, Ni100 and Ni1000.
Technical Data
Electrical Data
Voltage 24 VDC Module Supply (Via G3 System Aux. Power Connection)
Input Type RTD (Resistive Temperature Detector), 4 per Module
Supported Sensor Type Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000
Supported Temperature Coefficients .00385; .00392; .//C
Resolution 15 bits plus sign
Data Format Signed Integer
Factory Calibrated Field Calibration w/ high tolerance ( .005%)
Calibration
100 ohm and 350 ohm resistors.
Input Update (filter) Rate Adjustable (5-20mS), factory default: 5ms
Accuracy 0.1% of full scale @ 25 C

Mechanical Data
I/O Connector M12 4 Pin Female. Speedcon (Compatible with 5 Pin)
Mass 247g/8.7 oz.

Operating Data
Temperature Range Ambient -23 C to 46 C (-10 F to 115 F )
Humidity 95% relative humidity: non-condensing
Ingress Protection IP65 (with appropriate assembly and terminations)

240- 320 G3 [Ex ia] NAMUR Input Module


The [Ex ia] module is for use with NAMUR certified intrinsically safe (IS) sensors.
Technical Data
Electrical Data
24 VDC Module Supply
Voltage
Sensor Supply = 8.2 VDC Nominal
Input Type NAMUR
Signal Current (0) 2.1 mA
NC (Normally Closed) Signal Current (1) 1.2 mA
Short Circuit Monitoring < 100
Open/Broken Wire Detection < 0.05 mA
Uo 9.6 V
Safety Parameter Output Maximums Io 13 mA
Po 31 mW
Diagnostics Open (broken wire) and Short Circuit

Certification

Module Marking (ATEX) II(1)GD


[Ex ia Ga] IIC [Ex ia Da] IIIC

Mechanical Data
I/O Connector M12 4 Pin Female Speedcon (Compatible with 5 Pin)
Mass 284g/10.0 oz.

Operating Data
Temperature Range Ambient -23 C to 46 C (-10 F to 115 F )
Humidity 95% relative humidity: non-condensing
Ingress Protection IP65 (with appropriate assembly and terminations)

18
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Sub-Bus Modules

Sub-Bus Valve Module


Provides Sub-Bus In and Aux. Power In
connections to a distributed valve manifold.

Description Part Number Weight


Sub-Bus
240-241 235g/8.3 oz.
Valve Module w/IO
Sub-Bus Valve Module
P580AEDS4010A00 336g/10.8 oz.
w/o IO
Sub-Bus Valve Module w/o
P580AEDS4010DRM 347g/11.2 oz
IO, with DIN Rail Clips

Sub-Bus Out Module


Provides Sub-Bus Out and Aux. Power Out
connections for I/O distribution.

Description Part Number Weight


Sub-Bus Out Module with
240-244 141g/5.0 oz.
DIN Rail Clips
Sub-Bus Out Module 240-183 130g/4.6 oz.
Sub-Bus Out Module
240-318 150g/5.3 oz.
for Intrinsically Safe

Dust Cover -
Sub-Bus In Module M12 Male 230-647
Provides Sub-Bus In and Aux. Power In connections
for I/O distribution.

Description Part Number Weight


Sub-Bus In Module with
240-246 141g/5.0 oz.
DIN Rail Clips
Sub-Bus In Module 240-185 130g/4.6 oz.
Sub-Bus In Module
240-318 150g/5.3 oz.
for Intrinsically Safe

Dust Cover -
M12 Female 230-1200

19
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

240-326 G3 4 Branch Sub-Bus HUB Module


The G3 HUB module allows for branch distribution from the I/O
side of the G3 System and can be integrated into the existing
G3 Series Sub-Bus configuration. Auto Addressing allows for
trouble free set up and configuration. Input, output, as well as
Valve manifolds can be attached to the available four Branches
on a HUB module. Each G3 System can support up to two
HUB modules, allowing for maximum flexibility. The HUB
module is transparent to the I/O side of the G3 and does not
reserve one of the potential sixteen positions.
As with all other G3 I/O modules, standard G3 display and ARM
functionality (storing of all parameters) is supported.

Technical Data
Electrical Data
Voltage 24 VDC Module Supply
4 Per HUB Module, 2 HUB Modules per G3 System (A HUB module cannot be connected to the Branch of
No. of HUB Branches
another HUB module)
HUB Branch Length 30 Meters Per Branch
Addressing Auto Addressing on Power Up (Branch I/O reserve capability)
Display/Diagnostics Onboard LCD Multi Function Display
G3 System Integration Integrated into existing G3 I/O Side
Topology Star, Tree and Hybrid

Mechanical Data
Branch Connector M12 5 Pin Female
Mass 255g/9.0 oz.

Operating Data
Temperature Range -23 C to 46 C (-10 F to 115 F)
Humidity 95% relative humidity: non-condensing
Ingress Protection IP65 (with appropriate assembly and terminations)

20
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Miscellaneous Modules

Auto Recovery Module (ARM)


Protects configuration information during a critical failure.
Allows configuration information to be saved and reloaded
to replacement module automatically.

Description Part Number Weight


ARM Module 240-182 127g/4.5 oz.

Terminator Module
Provides termination for the Sub-Bus. Must be installed
after the last I/O module or after the communications
module if there are no I/O modules installed.

Description Part Number Weight


Terminator Module
240-245 102g/3.6 oz.
w/DIN Rail Clips
Terminator Module 240-184 91g/3.2 oz.

Jumper Clip
Provides electrical connections between modules.

Description Part Number Weight


Jumper Clip 240-179 45g/1.6 oz.
Jumper Clip for Intrinsically Safe 240-317 65g/2.3 oz.

21
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Miscellaneous Modules

Valve Driver Module


Provides connections between the communication module or
Sub-Bus valve module and the valve manifold.

Generation 2000, ISO 5599/2 and ISO 15407-2 Series


Description Part Number Weight
Valve Driver Module
219-858 147g/5.2 oz.
w/DIN Rail Clips
Valve Driver Module 219-828 136g/4.8 oz.

501, 502 and 503 Series Valves


Description Part Number
Valve Driver Module P599AE508827001
Valve Driver Module
P599AE508827002
w/DIN Rail Clips

Right Hand Mounting Cover


Used when a communications module is used without local
valves installed.

Description Part Number Weight


Right Hand Mounting Cover
240-290 82g/2.9 oz.
w/DIN Rail Clips*
Right Hand Mounting Cover* 240-255 71g/2.5 oz.

* Not for use in combination with ARM Module

Accessories
For use with Murrplastik Type 20 Software.

{
Labels - 122-1251
Technical Data
Material Polycarbonate (PC)
Color White
-40 C to 140 C
Temperature Range
(-40 F to 284 F)
Label Dimensions 0.19" x 0.39"
Label - Printable Area 0.19" x 0.39"

22
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Dimensions: mm (Inches)
Dimensional Drawing - G3 Fieldbus Manifold Assembly
503 Series Valve Manifold Assembly with G3 Electronics and Sub-Bus Output

6.3 Wide Slot


(2) Places
5.
4
C

M
A

D
E
B

L
F G H J K

AD
Y Z AA

W X

AC
AB
N
P
Q

R S T
U

A B C D E F G H J K L M N P
105.5 6.3 38 52.8 33.8 7 57.5 67.5 71.7 39.1 75.8 68.1 56.3

(4.154) (0.248) (1.5) (2.08) (1.33) (0.28) (2.264) (2.66) (2.82) (1.54) (2.984) (2.68) (2.217)

Q R S T U V W X Y Z AA AB AC AD
54 24.8 67.5 36.9 221.3 368.6 12.5 24.8 53 55.1 101.1 112.9 207

(2.13) (0.98) (2.66) (1.45) (8.713) (14.51) (0.49) (0.976) (2.087) (2.17) (3.98) (4.445) (8.2)

NOTE: For valve manifold dimensions refer to Valve Series product catalogs.

23
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Dimensions: Inches (mm)


Dimensional Drawing - G3 Fieldbus I/O Assembly
I/O Assembly with G3 Electronics and Sub-Bus Input

FOR USE WITH


OPTIONAL
DIN RAIL HARDWARE

E F

G ADDITIONAL MOUNTING HOLES (4)


FOR USE WITH M5 OR #10 SCREWS

H D A B C

R
N

K L M S T
U
J
VIEW SHOWN WITH OPTIONAL DIN
RAIL HARDWARE AND 35mm DIN
RAIL

A B C D E F G H J K L M N P R S T U
1.82 2.66 2.26 0.27 4.15 1.50 1.33 0.25 7.29 0.53 2.65 1.45 2.13 0.49 2.46 0.20 2.32 4.65
(46.35) (67.50) (57.50) (6.90) (105.50) (38.00) (33.75) (6.25) (185.25) (13.50) (67.25) (36.75) (54.00) (12.50) (62.50) (5.05) (59.00) (118.00)

24
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Manifold Assembly How to Order

K 501 A V 3 D 2 0 0 V A00
Port Type Options
8 = NPTF1 A00 = Standard (No Options)
G = ISO228/1-G1 MUF = Muffler in End Plates
K = Push-In Fittings DRM = DIN Rail Mount
DWM = DIN Rail with MUF
Product Series 14X = External Pilot Supply from Port # 14
501 = 11mm Valve D12 = (14X) External Pilot Supply from Port #14
502 = 18mm Valve and (MUF) Muffler in End Plates
503 = 26mm Valve D14 = (14X) External Pilot Supply from Port #14
and (DRM) DIN Rail Mount
Revision F06 = (14X) External Pilot Supply from Port
A = Initial Release #14, (MUF) Muffler in End Plates, and
(DRM) DIN Rail Mount
Product Type
V = Valve Manifold Assembly End Plate Style
V = Vertical
Electronics
3 = G3 Fieldbus Electronics Second Valve Series4
0 = No Second Valve Series
Number of Valve Stations2 1 = 501
B = 2 R = 18 2 = 502
C = 3 S = 19
D = 4 T = 20 Port Size3
F = 6 U = 21 1 = 1/8
G = 7 V = 22 2 = 1/4
H = 8 W = 23 G = 5/16
I = 9 X = 24 3 = 3/8
J = 10 Y = 25 4 = 1/2
K = 11 Z = 26 H = 8mm
L = 12 2 = 27 K = 10mm
M = 13 3 = 28 M = 12mm
N = 14 4 = 29
O = 15 5 = 30
P = 16 6 = 31
Q = 17 7 = 32

1  ort Type '8' and 'G' only available in Port Size 3/8 for 502 & 503 and 1/8 for 501
P
2 501 Not available with 2 Stations, 502 and 503 only available with 2, 4, 6, 8, 10
3 501 Port Sizes 1/8, 1/4, 5/16, 8mm, 502 and 503 Port Sizes 3/8, 1/2, 10 and 12mm
4 With 502 11mm (501) valve available, with 503 18mm (502) valve available

25
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order: Sub-Bus Valve Manifold without I/O or Additional Distribution

Shaded components are described by the manifold assembly number. The communications module is described by
the Electronic Interface model number designation.
Each valve station is listed in sequential order from left to right when facing the port side of the manifold as shown.

NOTE:
A total of 32 solenoid outputs are available. Either 32 single solenoid valves or 16 double solenoid valves or any
combination of singles and doubles not to exceed 32 outputs can be specified.

Example Order - 503 Shown


Assembly Kit 8503AV8H100VMUF
Valve Station #1 R503A2B40MA00F1
Valve Station #2 R503A2B40MA00F1
Mounting #1 8503AMM22MA0010
Valve Station #3 R503A2B40MA00F1
Valve Station #4 R503A2B40MA00F1
Mounting #2 8503AMM22MA0010
Valve Station #5 R503A2B40MA00F1
Valve Station #6 R503A2B40MA00F1
Mounting #3 8503AMM22MA0010
Valve Station #7 R503A2B40MA00F1
Valve Station #8 R503A2B40MA00F1
Mounting #4 8503AMM22MA0010
Electronics P580AEDS4010A00
Assembled

26
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How To Order
G3 Assembly Kit
A K 3 E D 0 0 0 0 3 L STD
Electrical/Electronic
Type & Location Special Options
3 = G3 Electronics STD = Standard
DRM = DIN Rail Mounting - Not available
Valve Series* w/2035 and ISO 5599/2
0 = N/A MUF = Muffler - Not available with ISO 5599/2
6 = 2002 - 02/R2 DWM = DIN Rail w/Muffler - Not available
E = 2005 w/2035 and ISO 5599/2
G = 2012
B = 2035
W = ISO 15407-2 18mm End Plate Port Type
X = ISO 15407-2 26mm L = Push-In Fitting
Q = ISO 5599/2 Size 1 N = NPTF Pressure Ports
R = ISO 5599/2 Size 2 (NPTF Conduit Ports if applicable)
S = ISO 5599/2 Size 3 G = ISP 228/1-G Tap Pressure Ports
(ISO 228/1-G Conduit Ports if applicable)
Number of Valve Stations
A = 1 I = 9 Q = 17 Y = 25 End Plate Port Size
B = 2 J = 10 R = 18 Z = 26 2 = 1/4
C = 3 K = 11 S = 19 2 = 27 3 = 3/8
D = 4 L = 12 T = 20 3 = 28 4 = 1/2
E = 5 M = 13 U = 21 4 = 29 6 = 1
F = 6 N = 14 V = 22 5 = 30 8 = 8mm (5/16)
G = 7 O = 15 W = 23 6 = 31 K = 10mm
H = 8 P = 16 X = 24 7 = 32 X = Two or more valve groups resulting in
different standard end plate port sizes
*For manifold assembly with multiple valve series - consult factory

How To Order
G3 Electronics
G3 EP1 00 R 0 STD

Series Options
G3 = G3 Electronics STD = Standard
DRM = DIN Rail Mounting
Electronics Protocol E23 = Fieldbus Assembly without Valves
CC1 = CC-Link IE Field E40 = Auto Recovery Module (ARM)
CO1 = CANopen E41 = G3 PROFIBUS Module with pass
DL1 = DeviceLogix through protective earth
DN1 = DeviceNet G32 = E40 + DRM
EC1 = EtherCAT G36 = E28 + E40
ED1 = EtherNet/IP DLR
EM1 = Ethernet Modbus TCP/IP Modification
EP1 = EtherNet/IP 0 = Initial Release
PL1 = Ethernet POWERLINK
PT1 = PROFIBUS DP
PN1 = PROFINET Left Mounting
DS2 = Sub-Bus Valve Manifold D = w/Sub-Bus Out
DS3 = Sub-Bus I/O Assembly R = w/Terminating Resistor

Number of I/O Modules


00 = 0 09 = 9
01 = 1 10 = 10
02 = 2 11 = 11
03 = 3 12 = 12
04 = 4 13 = 13
05 = 5 14 = 14
06 = 6 15 = 15
07 = 7 16 = 16
08 = 8

27
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Ordering Valve Manifold Assemblies with G3 Electronics & Discrete I/O


For valve series 2002, 2005, 2012, 2035, ISO 15407-2 & ISO 5599/2 (2005 shown)

16 1 1 2 3 15 16

Shaded components are described by the assembly kit (AK) model number Example Order - 2005 Shown
(see page 27). The communications module and number of I/O modules are Assembly Kit AK3EP00003LMUF
described by the Electronic Interface (G3) model number designation (see Station 1 052BB4Z2ML00061
page 27). Station 2 052BB4Z2ML00061
Station 3 052BB4Z2ML00061
Each valve station is listed in sequential order from left to right when facing Station 4 052BB4Z2ML00061
the port side of the manifold as shown. Station 5 052BB4Z2ML00061
Station 6 052BB4Z2ML00061
Each discrete I/O module is listed in sequential order from RIGHT to LEFT Station 7 052BB4Z2ML00061
starting from the communication module as shown. Station 8 052BB4Z2ML00061
Station 9 052BB4R2ML00061
NOTE: Station 10 052BB4Z2ML00061
1. A total of 32 solenoid outputs are available. Either 32 single solenoid Station 11 052BB4Z2ML00061
valves or 16 double solenoid valves or any combination of singles and Station 12 052BB4Z2ML00061
Station 13 052BB4Z2ML00061
doubles not to exceed 32 outputs can be specified. Station 14 052BB4Z2ML00061
2. For manifold assemblies that exceed 16 solenoids, the assembly MUST Station 15 052BB4Z2ML00061
be configured so that an even number of solenoids are utilized prior Station 16 052BB4Z2ML00061
Electronics G3DN116R0E40
to the station using the ribbon cable feature. The 16th and the 17th Station 1 240-205
solenoids cannot be on the same valve. Station 2 240-205

Station 15 240-205
Station 16 240-205
How To Order
G3 Electronics

16 1

1. Refer to the selection table on page 27 to specify the control electronics Example Order - I/O assembly
and I/O configuration. with Sub-Bus In and Sub-Bus Out
2. Each discrete I/O module is listed in sequential order from RIGHT to modules
LEFT as shown. Electronics G3DS316D0STD
Station 1 240-205
3. A maximum of 16 I/O modules are supported by a single Station 2 240-205
communication node. Analog I/O & digital I/O (NPN & PNP)
Station 15 240-205
Station 16 240-205

28
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
501 SERIES

Performance Data
Valve Data Min. Max.
Pilot Pressure Range 29 PSI (2 Bar) 115 PSI (8 Bar)
Valve Operating Pressure Range 28" HG Vacuum 115 PSI (8 Bar)
Ambient Temperature Range -10 C (-14 F) 50 C (122 F)

Proprietary
NL/m
Valve Flow Data Cv
(6 - 5 Bar)
5/2, Double Solenoid & Single Solenoid, Spring Return 0.46 460
2x 3/2 NC-NC 0.45 450
2x 3/2 NO-NO 0.45 450
Double Solenoid, 3 pos. 4 way, Spring Centered-
0.46 460
Open to 4 and 2 in center
Double Solenoid, 3 pos. 4 way, Spring Centered - single solenoid air pilot double
12 2solenoid
4 air pilot
14
0.46 460
Open Center single solenoid
2 position 4-wayair pilot 2 position 4-way
2 position 4-way
Double Solenoid, 3 pos. 4 way, Spring Centered - (B) (B)(A) (A) (B) 315
(B)(A) (A)
0.46 460 12 2 4 14 12 2 4 14
Closed Center
12 2 4 14
double solenoid air pilot
315 315
2 position 4-way
(EB)(P)(EA) (EB)(P)(EA)
315

12 2 4 14
double solenoid air pilot
double solenoid air pilot double solenoid air pilot
3 position 4-way4-way
3 position 3 position 4-way
Operating Data open center
open center 3closed
15 center
All Solenoids Are Continuous Duty Rated 24 VDC (B) (B)(A)
2 4
(A) (B) (B)(A)
24
(A)
14
12 14 12
12
double solenoid air pilot 24 14
Power (Watts) 0.8 3 position 4-way
closed center
315 33115 5
(EB)(P)(EA) (EB)(P)(EA)
14 4 2 12
double solenoid air pilot
(B) (B) (A) (A)
3 position 4-way
12 2 4
double solenoidpressure
air pilotcenter 14

Rubber Seal 2 position dual 3-way 3 15

Response Time (ms) 14(A) & 12(B) NO


Energize Deenergize double solenoid 12
3 12 5 4 14
2 position dual 3-way (EB) (P) (EA)
5/2, Single Solenoid, Spring Return 14 29
14 & 12 NO
(B) (A)
5/2, Double Solenoid 11 N/A (B)
2
3
4
1 5 (A)
double solenoid air pilot 12 14
5/3 Spring Centered 15 20 2 position dual 3-way
double solenoid 12 2 4 14

2x 3/2 NC 18 18 14(A)2&position
12(B)dual
NC3-way
14 & 12 NC 3 1 5
2x 3/2 NO 18 18 (EB) (P) 3 (EA)
1 5

(B) (B) (A) (A)


12 2 4 14
double solenoid air pilot
2 position dual 3-way
14(A)NC, 12(B) NO 3 1 5
(EB) (P) (EA)

29
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valve
R 501 A 2 B 4 0 M A00 F1
Product Series
501 = 11mm Valve Voltage
F1 = 24 DC
Revision
A = Initial Release Options
A00 = Standard (No Options)
Actuation 11B = Flush Locking Manual
2 = Rubber Packed Override
11M = Without Manual Override
Valve Type
B = Solenoid Pilot w/Flush Non-Locking Override Electrical
M = Plug-in, w/Light, VDC
Function
1 = 2 Position 4-Way (5/2), Spring Return
4 = 2 Position 4-Way (5/2), Dual Solenoid Port Size
5 = 3 Position 4-Way (5/3), Open Center, Dual Pressure 0 = No Port Size
6 = 3 Position 4-Way (5/3), Blocked Center
7 = 3 Position 4-way (5/3), Open to A & B in Center
A = Dual 3-way, A Normally Open - B Normally Open
D = Dual 3-way, A Normally Closed - B Normally Closed
N = Differential Air Return w/o Spring

Regulator
R 501 A R S 5 1 J A00 1 0
Product Series
501 = 11mm Valve Interface
1 = Proprietary
Revision
A = Initial Release Options
A00 = Standard (No Options)
Product Type 12H = Regulator Less Gauge
R = Regulator 18V = Regulator with Gauge in
Offset Port
Regulator Type
S = Single Reg. - Pressure to Port 1 Wiring Option
J = Plug-In, Receptacle Assembly
Pressure Range
5 = 10 - 115 PSIG Gauge Type
1 = PSI

Sandwich Pressure Regulators


Type: RS Type RS

2 4

3 5

Single pressure from a single supply 1


30
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
503 SERIES

5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and Rubber


Seal, Cv: 1.2 - 1.4
Solenoid air pilot actuated
Low wattage 1.7 watt for DC application
DC solenoids polarity insensitive with surge suppression
Plug together circuit boards eliminate internal wiring
Integral recessed gaskets
IN Fittings to accommodate various tube sizes
Simple conversion from internal to external pilot
G3 Fieldbus electronics
IP65 Certified

Performance Data
12 2 4 14
single solenoid air pilot
Valve Data Min. Max. 2 position 4-way
315
Pilot Pressure Range 29 PSI (2 Bar) 115 PSI (8 Bar)
Valve Operating Pressure Range 28" HG Vacuum 115 PSI (8 Bar) 12 2 4 14
double solenoid air pilot
Ambient Temperature Range -10 C (-14 F) 50 C (122 F) 2 position 4-way
(Spool & Sleeve) 315

ISO Proprietary 12 2 4 14
double solenoid air pilot
NL/m NL/m 3 position 4-way
Valve Flow Data Cv Cv
(6 - 5 Bar) (6 - 5 Bar) open center 315

5/2, Double Solenoid & Single Solenoid,


1.1 1100 1.2 1200
Spring Return (Spool & Sleeve) double solenoid air pilot 12 24 14

5/2, Double Solenoid & Single Solenoid, 3 position 4-way


1.2 1200 1.4 1400 closed center
Spring Return (Rubber Seal) 315

2x 3/2 NC-NC 0.9 900 1.0 1000 14 4 2 12


double solenoid air pilot
2x 3/2 NO-NO 0.9 900 1.0 1000 3 position 4-way
pressure center
Double Solenoid, 3 pos. 4 way, Spring
0.6 600 0.6 600 3 15
Centered- Open to 4 and 2 in center
Double Solenoid, 3 pos. 4 way, Spring double solenoid 12 2 4 14
1.1 1100 1.3 1300 2 position dual 3-way
Centered - Open Center
14 & 12 NO
Double Solenoid, 3 pos. 4 way, Spring
3 1 5
1.2 1200 1.4 1400
Centered - Closed Center
double solenoid 12 2 4 14
2 position dual 3-way
14 & 12 NC
3 1 5

Operating Data
All Solenoids Are Continuous Duty Rated 24 VDC
Power (Watts) 1.7
Holding Current (Amps) 0.071

Spool & Sleeve Rubber Seal


Response Time (ms)
Energize Deenergize Energize Deenergize
5/2, Single Solenoid, Spring Return 20 60 20 60
5/2, Double Solenoid 15 N/A 20 N/A
5/3 Spring Centered 15 20
2x 3/2 NC 15 25
2x 3/2 NO 15 20

31
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valve
R 503 A 2 B 4 0 M A00 F1

Product Series Voltage


503 = 26mm Valve F1 = 24 VDC
Revision Options
A = Initial Release A00 = Standard (No Options)
11B = Flush Locking Manual
Valve Type Override
1 = Spool and Sleeve* 11M = Without Manual Override
2 = Rubber Packed
Electrical
Actuation
M = Plug-in, w/Light, VDC
B = Solenoid Pilot with Flush Non-Locking Override
N = M12 Connector Pin#1 =
unused, #2 = Coil 12, #3 =
Function Common, #4 = Coil 14
1 = 2 Position 4-Way (5/2), Spring Return
4 = 2 Position 4-Way (5/2), Dual Solenoid Port Size
5 = 3 Position 4-Way (5/3), Open Center, Dual Pressure 0 = No Port Size
6 = 3 Position 4-Way (5/3), Blocked Center
7 = 3 Position 4-way (5/3), Open to A & B in Center
A = Dual 3-way, A Normally Open - B Normally Open
D = Dual 3-way, A Normally Closed - B Normally
Closed
N = Differential Air Return w/o Spring
* Available with Functions 1 + 4 only.

Regulator
R 503 A R S 1 1 J A00 1 0

Product Series Reserved


503 = 26mm Valve
Interface
Revision
1 = Proprietary
A = Initial Release
2 = ISO 15407-2
Product Type 0 = No Interface*
R = Regulator
Options
Regulator Type A00 = Standard (No Options)
S = Single Reg. - Pressure to Port 1 16N = Jumper for Supply Pressure to
D = Double Reg. - Pressure to Ports 5 & 3 Valve, 14 End
E = Double Reg. - Pressure to Ports 4 & 2, w/o Valve* 16P = Jumper for Supply Pressure to
T = Double Reg. - Pressure to Ports 1 & 3, 2 Valve, 12 End
Pressure Selector
Pressure Range Wiring Options
1 = 10 - 130 PSIG (0.7 - 9 bar) J = Plug-in, Receptacle Assembly
3 = 3 - 30 PSIG (0.2 - 2 bar) 0 = Non Plug-In*
4 = 5 - 60 PSIG (0.3 - 4.1 bar)
Gauge Type
1 = PSI
* For Regulator Type "E" must select "0" wiring option + "0" interface.
2 = bar

32
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
2002 R2 & 02 SERIES
single solenoid air pilot double solenoid air pilot
2002-R2
2single
position & 02
4-way
solenoid Series Functions
air pilot 2double
position 4-way air pilot
solenoid
2 position
(B) (B)(A) 4-way (A) 2 position
(B) (B)(A)4-way (A) 5 Ported, 2 and 3 position, 4-way and dual 3-way,
12 2 4 14 12 2 4 14
(B) (B)(A) (A) (B) (B)(A) (A) Packed Spool
12 2 4 14 12 2 4 14
Cv: 0.25 (4-way)
315 315
(EB)(P)(EA)
315
(EB)(P)(EA)
315
0.25 (Dual 3-way) R2 Series
double solenoid
(EB)(P)(EA) air pilot double solenoid
(EB)(P)(EA) air pilot Spool and Sleeve
3double
position 4-way air pilot
solenoid 3double
position 4-way air pilot
solenoid Cv: 0.20 (4-way) 02 Series
open center
3 position 4-way closed center
3 position 4-way Solenoid air pilot actuated
(B) (B)(A) (A) (B) (B)(A) (A)
open
12
center
2 4 14
closed
12
center
24 14 Low wattage coil
(B) (B)(A) (A) (B) (B)(A) (A)
12 2 4 14 12 24 14 Elimination of internal wiring
315 315 Buna-N seals provide leakproof sealing
(EB)(P)(EA) (EB)(P)(EA)
315 315
Pusher piston high spool shifting force
2002-R2 Series Only Functions
(EB)(P)(EA) (EB)(P)(EA)
(B) (B) (A)
double solenoid 12 2 4
(A)
Adjustable port sizes utilizing interchangeable
14
air pilot solenoid
double (B) (B) (A) (A) cartridge fittings
12 2 4 14
dual 3-way
air pilot
12(B) & 14(A) NO
dual 3-way 3 1 5
(EB) (P) (EA)
12(B) & 14(A) NO 3 1 5
(EB) (P) (EA)
(B) (B) (A) (A)
double solenoid 12 2 4 14
air pilot solenoid
double
(B) (B) (A) (A)
12 2 4 14
dual 3-way
air pilot
3 1 5
12(B) & 14(A) NC
dual 3-way (EB) (P) (EA)
3 1 5
12(B) & 14(A) NC (EB) (P) (EA)
(B) (B) (A) (A)
double solenoid 12 2 4 14
(B) (B) (A) (A)
air pilot solenoid
double 12 2 4 14
2airposition
pilot dual 3-way
3 1 5
12(B) NO,dual
2 position 14(A) NC
3-way (EB) (P) (EA)
3 1 5
12(B) NO, 14(A) NC (EB) (P) (EA)

Technical Data
English Metric
Valve Data
R2 Series 02 Series R2 Series 02 Series
Cv 0.25 0.2 0.25 0.2
11.5 SCFM @ 80 PSIG 9.2 SCFM @ 80 PSIG 246 NI/m @ 6 bar upstream 197 NI/m @ 6 bar upstream
Flow Capacity upstream pressure to upstream pressure to pressure to 5 bar downstream pressure to 5 bar downstream
atmosphere atmosphere
Operating Pressure Range 28" Hg to 100 PSIG 28" Hg to 150 PSIG Vacuum to 7 bar Vacuum to 10 bar
Pilot Pressure Range 35 to 100 PSIG 35 to 100 PSIG 2.5 to 7 bar 2.5 to 7 bar
Temperature Range -10 F to 115 F -10 F to 115 F -23 C to 50 C -23 C to 50 C
(Ambient)

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 0.5
Holding Current (Amps) 0.02

Response Time Energize De-Energize


in Seconds R2 Series 02 Series R2 Series 02 Series
2-Position, Single, Spring Return 0.017 0.014 0.013 0.20

2-Position, Double, Detented 0.010 0.010 N/A N/A

3-Position, Spring Centered 0.009 0.009 0.022 0.057

Dual 3-way 0.018 N/A 0.010 N/A

33
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How To Order
Valves
R2 1 BB A Z4 M K 000 61
Series Identifier
02 = Spool/Sleeve with Voltage
Body to Base Plug 61 = 24 VDC
R2 = Rubber Packed Spool 00 = Use w/Blank Station Plate
with Body to Base Plug
Options
Port Size 11B = Flush Locking Manual Override
1 = 1/8 14A = External Pilot Supply
2 = 1/4 000 = No Option
D = 5/32 (4mm) (Port Type "K" Only)
F = 6mm (Port Type "K" Only) Port Type
K = Push-In Fitting
Valve Type H = Barbed Fitting
BW = Solenoid Pilot w/Flush Non-Locking Manual
Override & Differential Air Return Wiring Option
BB = Double Solenoid Pilot w/Flush Non-Locking M = Plug-In DC, w/Light
Manual Override 0 = Blank Station
00 = Blank Station
Mounting
Function
Z3 = Manifold Block, Side Ports
4 = 2 Position 4-Way Only, Single Solenoid Output
5 = 3 Position 4-Way, Open Center, Dual Pressure Z4 = Manifold Block, Side Ports
6 = 3 Position 4-Way, Closed Center Only, Double Solenoid Output
A = Dual 3-way, A Normally Open - B Normally Open
C = Dual 3-Way, A Normally Closed - B Normally Open
D = Dual 3-way, A Normally Closed - B Normally Closed
P = Blank Station Plate

34
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
2005 SERIES

single solenoid air pilot double solenoid air pilot 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve
2 position 4-way 2 position 4-way Cv: 0.56
14 4 2 12 4 2
Dual 3-Way Pack Spool
14 12

51 3
Cv: 0.56
51 3
Solenoid air pilot actuated
double solenoid air pilot double solenoid air pilot
Low wattage coil
3 position 4-way 3 position 4-way
open center closed center DC solenoids polarity insensitive with spike
suppression
14 42 12 14 42 12
Plug together circuit boards eliminate internal wiring
51 3 51 3 Integral recessed gaskets
Interchangeable Push-In fittings to accommodate
double solenoid air pilot 14 4 2 12
various tube sizes
3 position 4-way
pressure center
Simple conversion from internal to external pilot
3 15
supply
(B) (B) (A) (A)
NEMA 4/IP65
double solenoid 12 2 4 14

2 position dual 3-way


14(A) & 12(B) NO
3 1 5
(EB) (P) (EA)

double solenoid (B) (B) (A) (A)


12 2 4 14
2 position dual 3-way
14(A) & 12(B) NC
3 1 5
(EB) (P) (EA)

(B) (A)
double solenoid (B)
12 2 4
(A)
14
2 position dual 3-way
14(A) NC , 12(B) NO
3 1 5
(EB) (P) (EA)

Technical Data
Valve Data English Metric
Cv 0.56 0.56
Flow Capacity 26 SCFM @ 80 PSIG upstream pressure to atmosphere 552 NI/m @ 6 bar upstream to 5 bar downstream
Operating Pressure Range 28" Hg Vacuum to 150 PSIG Vacuum to 10 bar
Operating Pressure Range 3 Way 22" Hg Vacuum to 100 PSIG Vacuum to 7 bar
Pilot Pressure Range 26 to 120 PSIG 1.8 to 8.2 bar
Pilot Pressure Range 3 Way 26 to 100 PSIG 1.8 to 7 bar
Pilot Pressure Vacuum 50 to 100 PSIG 3.5 to 7 bar
Temperature Range (Ambient) -10 F to 115 F -23 C to 50 C

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 1.35
Holding Current (Amps) 0.056

Response Time
Energize De-Energize
in Seconds
2-Position, Single, Spring Return 0.014 0.016

2-Position, Double, Detented 0.013 N/A

3-Position, Spring Centered 0.014 0.016

Dual 3-way 0.014 0.016

35
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valves
051 BB 4 Z6 M N 000 61
Valve Series & Port Size
051 = 1/8 (Threaded Only) Voltage
052 = 1/4 (Push-In Only) 61 = 24 VDC
05F = 6mm 00 = Use w/Blank Station Plate
05H = 8mm
Options
11B = Flush Locking Manual Override
Valve Type 11M = No Override
BA = Single Solenoid Pilot (Spring Return) w/Flush
000 = No Option
Non-Locking Override
BB = Double Solenoid Pilot w/Flush Non-Locking
Override Port Type
00 = Blank Station L = Push-In Fitting
N = NPTF (1/8 Only)
G = G Tap (1/8 Only)
Function
4 = 2 Position 4-Way
Wiring Option
5 = 3 Position 4-Way, Open Center
M = Plug-In DC, w/Light
6 = 3 Position 4-Way, Closed Center
0 = Blank Station
7 = 3 Position, 4-Way Pressure Center
A = Dual 3-Way, A Normally Open - B Normally Open
Mounting
B = Dual 3-Way, Vacuum Service, A Normally Open -
B Normally Open Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
D = Dual 3-way, A Normally Closed - B Normally Closed
Z2 = Manifold Block w/Side and Bottom Ports,
E = Dual 3-Way, Vacuum Service, A Normally Closed - Double Solenoid Internal Circuit Board
B Normally Closed
Z5 = Z1 w/Speed Control
P = Blank Station Plate
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

Regulators
051 RS 1 Z1 J K 000 00
Valve Series & Port Size
051 = 1/8 Options
052 = 1/4 (Push-In Only) 12H = Less Gauge
05F = 6mm 16N = Jumper on 14 (A) End
05H = 8mm 16P = Jumper on 12 (B) End
* Use for Regulator Unit Only (Mounting = 00) 16W = Top Facing Gauge
61Y = Extended Gauge See
NOTE
Regulator Type 63D = 16W + 61Y Extended Below
RS = Single Pressure to Port 1 (P) Top Facing Gauge
RD = Dual Pressure to Ports 3 (EB) & 5 (EA) 000 = No Option
RE = Dual Pressure to Ports 4 (4) & 2 (B)
RT = 2 Pressure Selector Port Type
* For Metric Gauge replace R with E in 4th digit K = Push-In
P = NPTF (1/8 Only)
Pressure Range Q = G Tap (1/8 Only)
1 = 10-130 PSIG (0.7-9 bar) Wiring Option
3 = 3-30 PSIG (0.2-2 bar) J = Plug-In Receptacle Assembly
4 = 5-60 PSIG (0.5-4 bar)

Mounting
Z0 = Manifold Block w/Side and Bottom Ports, Transfer board, used w/RE Regulators
Z1 = Manifold Block w/Side and Bottom Ports, Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports, Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

NOTE: Regulator Gauges must be offset on alternating stations to prevent interference (see photo)
* Odd numbered stations will use either standard (no option) or top facing (16W option) gauges
Even numbered stations will use either extended standard (61Y option) or extended top facing (63D option) gauges
36
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
2012 SERIES

single solenoid air pilot double solenoid air pilot 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve
2 position 4-way 2 position 4-way Cv: 1.2
Solenoid air pilot actuated
(B) (B) (A) (A) (B) (B) (A) (A)
12 2 4 14 12 2 4 14 Low wattage coil
DC solenoids polarity insensitive with spike
315 315
suppression
(EB)(P)(EA) (EB)(P)(EA)
Plug together circuit boards eliminate internal wiring
Integral recessed gaskets
double solenoid air pilot double solenoid air pilot Interchangeable Push-In fittings to accommodate
3 position 4-way 3 position 4-way various tube sizes
open center closed center Simple conversion from internal to external pilot
(B) (B) (A) (A) (B) (B)(A) (A) NEMA 4/IP65
12 2 4 14 12 24 14

315 315
(EB)(P)(EA) (EB)(P)(EA)

double solenoid air pilot 14 4 2 12


3 position 4-way
pressure center
3 15

Technical Data
Valve Data English Metric
Cv 1.20 1.20
Flow Capacity 56 SCFM @ 80 PSIG upstream pressure to atmosphere 1180 NI/m @ 6 bar upstream to 5 bar downstream
Operating Pressure Range 28" Hg Vacuum to 150 PSIG Vacuum to 10 bar
Pilot Pressure Range 26 to 120 PSIG 1.8 to 8.2 bar
Temperature Range (Ambient) -10 F to 115 F -23 C to 50 C

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 2.5
Holding Current (Amps) 0.10

Response Time
Energize De-Energize
in Seconds
2-Position, Single, Spring Return 0.010 0.020
2-Position, Double, Detented 0.010 N/A
3-Position, Spring Centered 0.010 0.020

37
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valves
122 BB 4 Z6 M L 000 61
Valve Series & Port Size
122 = 1/4 Voltage
123 = 3/8 61 = 24 VDC
12H = 8mm 00 = Use w/Blank Station Plate
12K = 10mm
Options
11B = Flush Locking Manual Override
Valve Type
11M = No Override
BA = Single Solenoid Pilot (Spring Return) w/Flush
Non-Locking Override 000 = No Option
BB = Double Solenoid Pilot w/Flush Non-Locking
Override Port Type
00 = Blank Station L = Push-In Fitting
N = NPTF
Function G = G Tap
4 = 2 Position 4-Way
5 = 3 Position 4-Way, Open Center
Wiring Option
M = Plug-In DC, w/Light
6 = 3 Position 4-Way, Closed Center
0 = Blank Station
7 = 3 Position, 4-Way Pressure Center
P = Blank Station Plate
Mounting
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

Regulators
122 RS 3 Z1 J L 000 00
Valve Series & Port Size
122 = 1/4 Options
123 = 3/8 12H = Less Gauge
12H = 8mm 16N = Jumper on 14 (A) End
12K = 10mm 16P = Jumper on 12 (B) End
16W = Top Facing Gauge
Regulator Type 000 = No Option
RS = Single Pressure to Port 1 (P)
RD = Dual Pressure to Ports 3 (EB) & 5 (EA) Port Type
RC = Dual Pressure w/Non-Relieving Checks L = Push-In
RQ = Dual Pressure w/Relieving Checks N = NPTF
RE = Dual Pressure to Ports 4 (4) & 2 (B) G = G Tap
RT = 2 Pressure Selector
* For Metric Gauge replace R with E in 4th digit Wiring Option
J = Plug-In Receptacle Assembly
Pressure Range O = Non-Plug-In (Type RE Only)
1 = 10-130 PSIG (0.7-9 bar)
3 = 3-30 PSIG (0.2-2 bar)
Mounting
Z0 = Manifold Block w/Side and Bottom Ports,
4 = 5-60 PSIG (0.5-4 bar)
Transfer board, used w/RE Regulators
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

38
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
2035 SERIES

single solenoid air pilot double solenoid air pilot 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve
2 position 4-way 2 position 4-way Cv: 3.5
(B) (B) (A) (A) (B) (B) (A) (A) Solenoid air pilot actuated
12 2 4 14 12 2 4 14
Low wattage coil
DC solenoids polarity insensitive with spike suppression
315 315
(EB)(P)(EA) (EB)(P)(EA) Plug together circuit boards eliminate internal wiring
Integral recessed gaskets
double solenoid air pilot double solenoid air pilot Simple conversion from internal to external pilot supply
3 position 4-way 3 position 4-way Designed to meet NEMA4/IP65
open center closed center Manifold connection allows disassembly at any station
(B) (B) (A) (A) (B) (B)(A) (A)
12 2 4 14 12 24 14

315 315
(EB)(P)(EA) (EB)(P)(EA)

double solenoid air pilot 14 4 2 12


3 position 4-way
pressure center
Technical Data
3 15

Valve Data English Metric


Cv 3.5* 3.5*
3500 Nl/m @ 6 bar upstream pressure to 5 bar
Flow Capacity 161 SCFM @ 80 PSIG upstream pressure to atmosphere atmosphere
Operating Pressure Range 28" Hg Vacuum to 145 PSIG Vacuum to 10 bar
Pilot Pressure Range 26.1 to 120 PSIG 1.8 to 8.2 bar
Temperature Range (Ambient) -10 F to 115 F -23 C to 50 C

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 2.5
Holding Current (Amps) 0.10

Response Time
Energize De-Energize
in Seconds**
2-Position, Single, Spring Return 0.021 0.067
2-Position, Double, Detented 0.017 N/A
3-Position, Spring Centered 0.021 0.072
* Valve on 1/2 NPTF Sub-Plate
** Per ISO 12238 Standard

39
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valves
353 BB 4 Z6 M N 000 61
Valve Series & Port Size
353 = 3/8 Voltage
354 = 1/2 61 = 24 VDC
00 = Use w/Blank Station Plate
Valve Type
BA = Single Solenoid Pilot (Spring Return) w/Flush Options
Non-Locking Override 11B = Flush Locking Manual Override
BB = Double Solenoid Pilot w/Flush Non-Locking 11M = No Override
Override 000 = No Option
00 = Blank Station
Port Type
Function N = NPTF
4 = 2 Position 4-Way G = G Tap
5 = 3 Position 4-Way, Open Center
6 = 3 Position 4-Way, Closed Center Wiring Option
P = Blank Station Plate M = Plug-In DC, w/Light
0 = Blank Station

Mounting
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

Regulators
353 RS 3 Z1 J N 000 00
Valve Series & Port Size
353 = 3/8 Options
354 = 1/2 12H = Less Gauge
16N = Jumper on 14 (A) End
Regulator Type 16P = Jumper on 12 (B) End
RS = Single Pressure to Port 1 (P) 16W = Top Facing Gauge
RD = Dual Pressure to Ports 3 (EB) & 5 (EA) 000 = No Option
RC = Dual Pressure w/Non-Relieving Checks
RQ = Dual Pressure w/Relieving Checks Port Type
RE = Dual Pressure to Ports 4 (4) & 2 (B) N = NPTF
RT = 2 Pressure Selector G = G Tap
* For Metric Gauge replace R with E in 4th digit
Wiring Option
Pressure Range J = Plug-In Receptacle Assembly
1 = 10-130 PSIG (0.7-9 bar) O = Non-Plug-In (Type RE Only)
3 = 3-30 PSIG (0.2-2 bar)
4 = 5-60 PSIG (0.5-4 bar) Mounting
Z0 = Manifold Block w/Side and Bottom Ports,
Transfer board, used w/RE Regulators
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

40
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
ISO 15407-2 18MM SERIES

single solenoid air pilot double solenoid air pilot 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve
2 position 4-way 2 position 4-way Cv: 0.56
14 4 2 12 14 4 2 12
Solenoid air pilot actuated

513 513
Low wattage coil
DC solenoids polarity insensitive with spike
suppression
double solenoid air pilot 3 position double solenoid air pilot 3 position
4-way open center 4-way closed center
Plug together circuit boards eliminate internal wiring
14 4 2 14 42
Integral recessed gaskets
12 12
Interchangeable Push-In fittings to accommodate
various tube sizes
513 513
Simple conversion from internal to external pilot
NEMA 4/IP65
double solenoid 2 position 3-way double solenoid 3 position 4-way,
14 & 12 NC open to 4 and 2 in center

12 2 4 14 12 2 4 14

3 1 5 3 1 5

Technical Data - 18mm


Valve Data English Metric
Cv 0.56 0.56
Flow Capacity 26 SCFM @ 80 PSIG upstream pressure to atmosphere 552 NI/m @ 6 bar upstream to 5 bar downstream
Operating Pressure Range 28" Hg Vacuum to 150 PSIG Vacuum to 10 bar
Pilot Pressure Range 26 to 120 PSIG 1.8 to 8.2 bar
Temperature Range (Ambient) -10 F to 115 F -23 C to 50 C

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 1.35
Holding Current (Amps) 0.056

Response Time
Energize De-Energize
in Seconds
2-Position, Single, Spring Return 0.014 0.016
2-Position, Double, Detented 0.013 N/A
3-Position, Spring Centered 0.014 0.016

41
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order 15407-2 18mm


Valves
I51 BB 4 Z6 M N 000 61
Valve Series & Port Size
I51 = 1/8 (Threaded Only) Voltage
I52 = 1/4 (Push-In Only) 61 = 24 VDC
I5F = 6mm 00 = Use w/Blank Station Plate
I5H = 8mm
Options
11B = Flush Locking Manual Override
Valve Type 11M = No Override
BA = Single Solenoid Pilot (Spring Return) w/Flush
000 = No Option
Non-Locking Override
BB = Double Solenoid Pilot w/Flush Non-Locking
Override Port Type
00 = Blank Station L = Push-In Fitting
N = NPTF (1/8 Only) or Valve Unit Only
G = G Tap (1/8 Only) ISO 228/I-G
Function
4 = 2 Position 4-Way
Wiring Option
5 = 3 Position 4-Way, Open Center
M = Plug-In DC, w/Light
6 = 3 Position 4-Way, Closed Center
0 = Blank Station
P = Blank Station Plate
Mounting
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

Regulators
I51 RS 1 Z1 J K 000 00
Valve Series & Port Size
I51 = 1/8 Options
I52 = 1/4 (Push-In Only) 12H = Less Gauge
I5F = 6mm 16N = Jumper on 14 (A) End
I5H = 8mm 16P = Jumper on 12 (B) End
16W = Top Facing Gauge
61Y = Extended Gauge See
Regulator Type NOTE
63D = 16W + 61Y Extended Below
RS = Single Pressure to Port 1 (P)
Top Facing Gauge
RD = Dual Pressure to Ports 3 (EB) & 5 (EA)
000 = No Option
RE = Dual Pressure to Ports 4 (4) & 2 (B)
RT = 2 Pressure Selector Port Type
L = Push-In
Pressure Range N = NPTF (1/8 Only)
1 = 10-130 PSIG (0.7-9 bar) G = G Tap (1/8 Only) ISO 228/I-G
3 = 3-30 PSIG (0.2-2 bar) Wiring Option
4 = 5-60 PSIG (0.5-4 bar) J = Plug-In Receptacle Assembly

Mounting
Z1 = Manifold Block w/Side and Bottom Ports, Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports, Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

NOTE: Regulator Gauges must be offset on alternating stations to prevent interference (see photo)
* Odd numbered stations will use either standard (no option) or top facing (16W option) gauges
Even numbered stations will use either extended standard (61Y opton) or extended top facing (63D option) gauges

42
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
ISO 15407-2 26MM SERIES

single solenoid air pilot double solenoid air pilot 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve
2 position 4-way 2 position 4-way Cv: 1.2
14 4 2 14 4 2 12
Solenoid air pilot actuated
12

513 513
Low wattage coil
DC solenoids polarity insensitive with spike suppression

double solenoid air pilot 3 position


Plug together circuit boards eliminate internal wiring
double solenoid air pilot 3 position
4-way open center 4-way closed center Integral recessed gaskets
14 4 2 12
14 42 12 Interchangeable Push-In fittings to accommodate various
tube sizes
513 513 Simple conversion from internal to external pilot
Modular plug-together Fieldbus electronics
double solenoid 2 position 3-way double solenoid 3 position 4-way,
NEMA 4/IP65
14 & 12 NC open to 4 and 2 in center

12 2 4 14 12 2 4 14

3 1 5 3 1 5

Technical Data - 26mm


Valve Data English Metric
Cv 1.20 1.20
Flow Capacity 56 SCFM @ 80 PSIG upstream pressure to atmosphere 1180 NI/m @ 6 bar upstream to 5 bar downstream
Operating Pressure Range 28" Hg Vacuum to 150 PSIG Vacuum to 10 bar
Pilot Pressure Range 26 to 120 PSIG 1.8 to 8.2 bar
Temperature Range (Ambient) -10 F to 115 F -23 C to 50 C

Operating Data
All Solenoids are Continuous Duty Rated 24 VDC
Power (Watts) 2.5
Holding Current (Amps) 0.10

Response Time
Energize De-Energize
in Seconds
2-Position, Single, Spring Return 0.010 0.020
2-Position, Double, Detented 0.010 N/A
3-Position, Spring Centered 0.010 0.020

43
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order 15407-2 26mm


Valves
I62 BB 4 Z6 M L 000 61
Valve Series & Port Size
I62 = 1/4 Voltage
I63 = 3/8 61 = 24 VDC
I6H = 8mm 00 = Use w/Blank Station Plate
I6K = 10mm
Options
11B = Flush Locking Manual Override
Valve Type
11M = No Override
BA = Single Solenoid Pilot (Spring Return) w/Flush
Non-Locking Override 000 = No Option
BB = Double Solenoid Pilot w/Flush Non-Locking
Override Port Type
00 = Blank Station L = Push-In Fitting
N = NPTF
Function G = G Tap ISO 228/I-G
4 = 2 Position 4-Way
5 = 3 Position 4-Way, Open Center
Wiring Option
M = Plug-In DC, w/Light
6 = 3 Position 4-Way, Closed Center
0 = Blank Station
P = Blank Station Plate
Mounting
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

Regulators
I62 RS 3 Z1 J L 000 00
Valve Series & Port Size
I62 = 1/4 Options
I63 = 3/8 12H = Less Gauge
I6H = 8mm 16N = Jumper on 14 (A) End
I6K = 10mm 16P = Jumper on 12 (B) End
16W = Top Facing Gauge
Regulator Type 000 = No Option
RS = Single Pressure to Port 1 (P)
RD = Dual Pressure to Ports 3 (EB) & 5 (EA) Port Type
RC = Dual Pressure w/Non-Relieving Checks L = Push-In
RQ = Dual Pressure w/Relieving Checks N = NPTF
RE = Dual Pressure to Ports 4 (4) & 2 (B) G = G Tap IOO 228/I-G
RT = 2 Pressure Selector
Wiring Option
Pressure Range J = Plug-In Receptacle Assembly
1 = 10-130 PSIG (0.7-9 bar) O = Non-Plug-In (Type RE Only)
3 = 3-30 PSIG (0.2-2 bar)
4 = 5-60 PSIG (0.5-4 bar) Mounting
Z0 = Manifold Block w/Side and Bottom Ports,
Transfer board, used w/RE Regulators
Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
Z2 = Manifold Block w/Side and Bottom Ports,
Double Solenoid Internal Circuit Board
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

44
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics
ISO 5599/2 SERIES

Direct Solenoid Actuated Solenoid Pilot Actuated


single solenoid double solenoid single solenoid double solenoid
2 position 4-way 2 position 4-way 2 position 4-way 2 position 4-way

double solenoid double solenoid


double solenoid double solenoid 3 position 4-way 3 position 4-way
3 position 4-way 3 position 4-way open center closed center
open center closed center

double solenoid double solenoid pilot


3 Position 4-Way (5/3), 3 Position 4-Way (5/3),
open to 4 (A) and open to 4 (A) and
double solenoid 2 (B) in center
2 (B) in center
3 Position 4-Way (5/3), B B A A 14 42 12
open to 4 (A) and
2 (B) in center
B B A A EB P EA 513
double solenoid pilot
3 Position 4-Way (5/3),
open to 4 (A) and
EB P EA 2 (B) in center
14 42 12

5 Ported, 4-way, 2 and 3 position, Spool & Sleeve,


Cv: 1.2 to 5.3 513

Direct and Solenoid Pilot Actuated


Complies with ISO Standard 5599/2- Sizes 1, 2 & 3
NEMA 4/IP 65

Technical Data
Direct Acting Solenoid Pilot Actuated
Valve Data
English Metric English Metric
Size 1 1.2 1.2 1.3 1.3
Cv Size 2 2 2 2.9 2.9
Size 3 NA NA 5.3 5.3

Size 1 55.5 SCFM 1181 NI/m 60.1 SCFM 1280 NI/m


Flow Capacity Size 2 101.7 SCFM 2168 NI/m 134.0 SCFM 2857 NI/m
Size 3 NA NA 245.0 SCFM 5222 NI/m

80 PSIG upstream 80 PSIG upstream


Main valve operating pressure range - 6 bar upstream 6 bar upstream
pressure to pressure to
All sizes to 5 bar downstream to 5 bar downstream
atmosphere atmosphere
Pilot pressure range - All sizes 28" Hg to 232 PSIG Vacuum to 16 bar 15 to 125 PSIG 1 to 8.6 bar
Temperature Range (Ambient) - -10 F to 115 F -23 C to 50 C -10 F to 115 F -23 C to 50 C
All sizes

Operating Data - All solenoids continuous duty rated


All Solenoids are 24 VDC Direct Acting 24 VDC Solenoid Pilot
Continuous Duty Rated Sizes 1 & 2 Size 3 Size 1 & 2 Size 3
Power (Watts) - All Sizes 6.0 NA 4.0 4.0
Holding Current (Amps) .25 NA 0.016 0.016
In-Rush Current (Amps) - All Sizes NA NA NA NA

Direct Acting Solenoid Pilot Actuated


Response Time Energize (Sec) De-Energize (Sec) Energize (Sec) De-Energize (Sec)
in Seconds Sizes 1
Sizes 1 & 2 Size 3 Size 3 Size 1 Size 2 Size 3 Size 1 Size 2 Size 3
&2
2-Position, Single, Spring Return 0.038 NA 0.012 NA 0.013 0.013 0.020 0.036 0.060 0.066
2-Position, Double, Detented 0.012 NA NA NA 0.013 0.013 0.020 NA NA NA
3-Position, Spring Centered 0.038 NA NA NA 0.013 0.013 0.020 0.036 0.060 0.066

45
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

How to Order
Valves
I24 BA 4 Z1 M P 000 61
Valve Series & Port Size
I12 = ISO 5599/2 Size 1 1/4" Voltage
I13 = ISO 5599/2 Size 1 3/8" 61 = 24 VDC
I23 = ISO 5599/2 Size 2 3/8" 00 = Use w/Blank Station Plate
I24 = ISO 5599/2 Size 2 1/2"
I34* = ISO 5599/2 Size 3 1/2" Options
I35* = ISO 5599/2 Size 3 3/4" 11B = Flush Locking Manual Override
11Z = Extended Locking Manual Override
1st Letter = "14" Actuator (Direct Acting Only)
2nd Letter = "12" Actuator 12A = FKM Seals on Sleeve Assembly
BA = Single Solenoid Pilot w/Spring Return 12B = Lubricant Free Assembly
BB = Double Solenoid 14C = Internal Pilot Supply from Port 3
(Solenoid Pilot Only)
BW = Solenoid Pilot w/Differential Air Return
14D = Internal Pilot Supply from Port 5
SA = Direct Solenoid w/Spring Return
(Solenoid Pilot Only)
SS = Double Direct Solenoid
14X = External Pilot Supply
00 = Blank Station
000 = No Option
Function
4 = 2 Position 4-Way Port Type
5 = 3 Position 4-Way, Open Center 0 = NPTF (Direct Solenoid Valves)
6 = 3 Position 4-Way, Closed Center G = G Tap (Direct Solenoid Valves) (Conforms
7 = 3 Position 4-Way (5/3), Open to 4 (A) to ISO Standards 1179-1 and 228-1)
and 2 (B) in Center P = NPTF (Solenoid Pilot Valves)
P = Blank Station Plate Q = G Tap (Solenoid Pilot Valves) (Conforms to
ISO Standards 1179-1 and 228-1)
Mounting Wiring Option
Z1 = Manifold Block w/Side and Bottom Ports, Single Solenoid Internal Circuit Board
M = Plug-In DC, w/Light
Z2 = Manifold Block w/Side and Bottom Ports, Double Solenoid Internal Circuit Board
0 = Blank Station
Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
NOTE: Standard for all ISO 5599/2 Solenoid Pilot Valve Series
R2 = Z2 w/Ribbon Cable Connector
is internal pilot supply from Port 1
R5 = Z5 w/Ribbon Cable Connector
* Not available in Direct Operated SA and SS Series
R6 = Z6 w/Ribbon Cable Connector

Regulators
I24 RS 1 Z1 J P 000 00
Valve Series & Port Size
I12 = ISO 5599/2 Size 1 1/4" Options
I13 = ISO 5599/2 Size 1 3/8" 16N = Jumper on 14 (A) End
I23 = ISO 5599/2 Size 2 3/8" 16P = Jumper on 12 (B) End
I24 = ISO 5599/2 Size 2 1/2" 000 = No Option
I34 = ISO 5599/2 Size 3 1/2"
I35 = ISO 5599/2 Size 3 3/4" Port Type
P = NPTF
Regulator Type Q = G Tap
RS = Single Pressure to Port 1 (P)
RD* = Dual Pressure to Ports 3 (EB) & 5 (EA) Wiring Option
RC* = Dual Pressure w/Non-Relieving Checks Air J = Plug-In Receptacle Assembly
Return (Sizes 2 & 3 Only) O = Non-Plug-In (Type RE Only)
RQ* = Dual Pressure w/Relieving Checks
RE = Dual Pressure, External Outlet Mounting
Z0 = Manifold Block w/Side and Bottom Ports,
Pressure Range Transfer board, used w/RE Regulators
1 = 10-130 PSIG (0.7-9 bar) Z1 = Manifold Block w/Side and Bottom Ports,
Single Solenoid Internal Circuit Board
3 = 3-30 PSIG (0.2-2 bar)
Z2 = Manifold Block w/Side and Bottom Ports,
4 = 5-60 PSIG (0.5-4 bar) Double Solenoid Internal Circuit Board
6 = 20-250 PSIG (1.4 - 17 bar) Z5 = Z1 w/Speed Control
Z6 = Z2 w/Speed Control
R1 = Z1 w/Ribbon Cable Connector
* Solenoid Pilot Valves used with RC, RD & RQ Regulators must
have the pilot supply from other than internally from Port 1 (P)
R2 = Z2 w/Ribbon Cable Connector
R5 = Z5 w/Ribbon Cable Connector
R6 = Z6 w/Ribbon Cable Connector

46
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
G3 POWER Electronics
CABLES & CONNECTORS

7/8" MINI Cables


4 Pin Cables for DeviceNet, DeviceLogix, Ethernet,
Modbus TCP/IP, CANopen, and Sub-Bus
7/8" MINI Straight 4 Pin Female Single Ended Cable, Euro Color Code
MC0405MAC0000000 5 Meter
MC0410MAC0000000 10 Meter

7/8" MINI 90 4 Pin Female Single Ended Cable, Euro Color Code
MD0405MAC0000000 5 Meter
MD0410MAC0000000 10 Meter

5 Pin Cables for PROFIBUS DP, PROFINET,


POWERLINK, and EtherCAT

7/8" MINI Straight 5 Pin Female Single Ended Cable, Euro Color Code
MC0505MAG0000000 5 Meter
MC0510MAG0000000 10 Meter

7/8" MINI 90 5 Pin Female Single Ended Cable, Euro Color Code
MD0505MAG0000000 5 Meter
MD0510MAG0000000 10 Meter

7/8" MINI Field Wireable Connectors


4 Pin Connectors for DeviceNet, DeviceLogix, Ethernet,
Modbus TCP/IP, CANopen, and Sub-Bus

7/8" MINI Straight 4 Pin Female Field Wireable Connector


MC04F90000000000 Cable Gland One size fits all

7/8" MINI 90 4 Pin Female Field Wireable Connector


MD04F20000000000 PG 9 Cable Gland

5 Pin Connectors for PROFIBUS DP, PROFINET and


POWERLINK, and EtherCAT

7/8" MINI Straight 5 Pin Female Field Wireable Connector


MC05F90000000000 Cable Gland One size fits all

7/8" MINI 90 5 Pin Female Field Wireable Connector


MD05F20000000000 PG 9 Cable Gland

47
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

M12 to 7/8" MINI Cable


4 Pin Cable for Sub-Bus Power

M12 Straight 4 Pin Male to 7/8" MINI 4 Pin Female Extension


TA0401MA0MC0471T 1 Meter
TA0405MA0MC0471T 5 Meter
TA0410MA0MC0471T 10 Meter

M12 Cables
4 Pin Cables for Sub-Bus Power

M12 Straight 4 Pin Female Single Ended Cable, Euro Color Code
TC0405MAE0000000 5 Meter
TC0410MAE0000000 10 Meter

M12 90 4 Pin Female Single Ended Cable, Euro Color Code


TD0405MAE0000000 5 Meter
TD0410MAE0000000 10 Meter

M12 Straight 4 Pin Male to Female Cable Extension


TC0401MAETA04000 1 Meter
TC0405MAETA04000 5 Meter
TC0410MAETA04000 10 Meter

M12 Field Wireable Connectors


4 Pin Connectors for Sub-Bus Power

M12 Straight 4 Pin Female Field Wireable Connector


TC04F10000000000 PG 7 Cable Gland
TC04F20000000000 PG 9 Cable Gland

M12 90 4 Pin Female Field Wireable Connector


TD04F10000000000 PG 7 Cable Gland
TD04F20000000000 PG 9 Cable Gland

48
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Pin Out and Technical Data


M12 Cable - Pin Out/Euro Color Code
(Male View)

1
2
3
4

7/8" MINI Cable - Pin Out/Euro Color Code

(Male View)

1
2
3
4

1
2
3
4
5

Technical Data M12 7/8" MINI


Molded Body/Insert Cable = PVC Field Wireable = Polyamide Cable = PVC Field Wireable = Polyamide or PBT
Coupling Nut Nickel Copper Alloy Black Anodized Aluminum/Die Cast Zinc
Cable Jacket Material PVC PVC
Cable O.D. 7.4mm 7.4mm (4 Pin & 5 Pin)
Voltage Rating (Nominal) 250 V Max. @ 105 C (221 F) 250 V Max. @ 105 C (221 F)
Current Rating Cables = 4.0 Amps Field Wireable = 4.0 Amps Cables = 5.5 Amps Field Wireable = 8.0 Amps
Degree of Protection IP67 (mated) IP67 (mated)
Operating Temperature -25 C to 85 C (-13 F to 185 F) -40 C to 85 C (-40 F to 185 F)
Conductor Gauge Cable = 18 AWG Cable = 18 AWG
Bend Radius Cable = 74mm Cable = 74mm (4 Pin & 5 Pin)
Maximum Wire AWG Field Wireable = 18 AWG Field Wireable = 16 AWG
Wire Connection Field Wireable = Screw Terminal Field Wireable = Screw Terminal
PG 7 Range 4-6mm N/A
PG 9 Range 6-8mm 5-13mm One size fits all
PG 13.5 Range N/A 5-13mm One size fits all

49
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3 G3 DEVICENET/
Electronics CANOPEN
CABLES & CONNECTORS

7/8" MINI Drop Cables


7/8" MINI Straight 5 Pin Female Single Ended Cable - Shielded
MC0505MGD0000000 5 Meter
MC0510MGD0000000 10 Meter

M12 Drop Cables


M12 Straight 5 Pin Female Single Ended Cable - Shielded
TC0505MGD0000000 5 Meter
TC0510MGD0000000 10 Meter

7/8" MINI 3 Way "T"


3 Way 7/8" MINI "T"
MC0500000MT05000

Terminating Resistors "TR"


7/8" MINI & M12 Straight 5 Pin Male Terminators
TA05TR0000000000 M12 Male
MA05TR0000000000 MINI Male

7/8" MINI Field Wireable Connectors


7/8" MINI Straight 5 Pin Field Wireable Connectors
MC05F90000000000 - Female - Cable Gland - One size fits all
MA05F90000000000 - Male - Cable Gland - One size fits all

MINI Cable - (Male View)


Pin Out/Color Code DRAIN
V+ (RED)
V- (BLACK)
CAN_H (WHITE)

M12 Cable - (Male View)


CAN_L (BLUE)

Pin Out/Color Code

Technical Data Cable T & TR Field Wireable


Molded Body/Insert PVC PVC Body = Glass Filled Polyamide

Nickel Plated Brass or


Coupling Nut Clear Anodized Aluminum Black Anodized Aluminum
Anodized Aluminum
Cable Jacket Material PVC N/A N/A
Cable O.D. MINI = 8mm M12 = 8mm N/A 5-13mm One size fits all
Voltage Rating (Nominal) 150 Volts T = 300 Volts 600 Volts
MINI = 4.0 Amps T = 8.0 Amps
Current Rating 8.0 Amps
MR = 3.0 Amps TR = NA
Degree of Protection IP65 (mated) IP65 (mated) IP65 (mated)
Operating Temperature -40 C to 80 C (-40 F to 176 F) -40 C to 105 C (-40 F to 221 F) -40 C to 90 C (-40 F to 194 F)
22 AWG Power
Conductor Gauge N/A 16-22 AWG
24 AWG Signal
Bend Radius Minimum Cable = 72mm N/A N/A
Wire Connection NA N/A Screw Terminal
50
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
G3 PROFINET Electronics
CABLES & CONNECTORS

M12 D-Coded Cables


M12 Straight 4 Pin Male D-Coded Single Ended Cable
QA0405MR00000000 5 Meter
QA0410MR00000000 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable


QA0405MR0QA04000 5 Meter
QA0410MR0QA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable


QA0405MR0VA04000 5 Meter
QA0410MR0VA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor


QA04D2MK0VC04000 0.2 Meter

M12 D-Coded Field Attachable Connectors


M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 PG 9 Cable Gland Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC


QA04F200R000071N PG 9 Cable Gland IDC

RJ45 Field Attachable Connectors


RJ45 Field Wireable Connector with IDC
VA08F200R000071N PG 9 Cable Gland

4 3 1 YE

M12 D-Coded Cable - (Male View)


2 WH

Pin Out/Color Code 3 OG


1 2 4 BU

Technical Data Cable RJ45 Field Attachable M12 Field Attachable


Body = Nickel Plated Zinc
Molded Body/Insert TPU Housing = PA Carrier = PC
Insert = PA 66
Coupling Nut Nickel Plated Zinc N/A Nickel Plated Brass
Cable Jacket Material PVC N/A N/A
Cable O.D. 6.5 to 7.4mm Accepts 4.5 to 8.0mm Accepts 6.0 to 8mm
Voltage Rating (Nominal) 250 Volts N/A 60 Volts
Current Rating 4.0 Amps 1.75 Amps Screw 4.0 Amps IDC 1.75 Amps
Degree of Protection IP65 (mated), RJ45 IP20 IP20 IP 65 (mated)
Operating Temperature -25 C to 60 C (-13 F to 140 F) -10 C to 60 C (14 F to 140 F) -40 C to 85 C (-40 F to 185 F)
Screw 24-18 AWG
Conductor Gauge 22 & 24 AWG 22 AWG Solid/Stranded
IDC 26-22 AWG
Bend Radius Minimum 19.5mm (fixed) 45.5mm (Flexible) N/A N/A
Wire Connection N/A IDC Screw Terminal, IDC

51
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics G3 POWERLINK
CABLES & CONNECTORS

M12 D-Coded Cables


M12 Straight 4 Pin Male D-Coded Double Ended Cable
QA0405MS0QA04000 5 Meter
QA0410MS0QA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable


QA0405MS0VA04000 5 Meter
QA0410MS0VA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket


Converter
QA04D2MK0VC04000 0.2 Meter

M12 D-Coded Field Attachable Connectors


M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 PG 9 Cable Gland Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/


IDC
QA04F200R000071N PG 9 Cable Gland IDC

RJ45 Field Attachable Connectors


RJ45 Field Wireable Connector with IDC
VA08F200R000071N PG 9 Cable Gland

4 3 2 1 shield shield
4 3
yellow yellow
M12 D-Coded Cable & RJ45
1 1 1 1
orange white
(Male View)
2 2 2 2

Pin Out/Color Code white blue


3 3 3 3
blue orange
4 4 4 4

1 2 M12 to M12
RJ45 to M12

Technical Data Cable RJ45 Field Attachable M12 Field Attachable


Body = Nickel Plated Zinc
Molded Body/Insert N/A Housing = PA Carrier = PC
Insert = PA 66
Coupling Nut Nickel Plated Zinc or Brass N/A Nickel Plated Brass
Cable Jacket Material PUR N/A N/A
Cable O.D. 6.5mm Accepts 4.5 to 8.0mm Accepts 6.0 to 8mm
Voltage Rating (Nominal) N/A N/A 60 Volts
Current Rating N/A 1.75 Amps Screw 4.0 Amps IDC 1.75 Amps
Degree of Protection IP65 (mated), RJ45 IP20 IP20 IP 65 (mated)
Operating Temperature -25 C to 60 C (-13 F to 140 F) -10 C to 60 C (14 F to 140 F) -40 C to 85 C (-40 F to 185 F)
Conductor Gauge 22 AWG 22 AWG Solid/Stranded Screw 24-18 AWG IDC 26-22 AWG
Bend Radius Minimum 45.5mm N/A N/A
Wire Connection N/A IDC Screw Terminal, IDC

52
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
G3 PROFIBUS DP Electronics
CABLES & CONNECTORS

M12 Reverse Key B-Coded Cables


M12 Straight 5 Pin Male Reverse Key Single Ended Cable - Shielded
RA0505MHP0000000 5 Meter
RA0510MHP0000000 10 Meter

M12 Straight 5 Pin Female Reverse Key Single Ended Cable - Shielded
RC0505MHP0000000 5 Meter
RC0510MHP0000000 10 Meter

M12 Straight 5 Pin MALE TO FEMALE Reverse Key EXTENSION CABLE


RC0505MHPRC05000 5 Meter
RC0510MHPRC05000 10 Meter

M12 Reverse Key B-Coded Field Wireable Connectors


M12 Straight 5 Pin Male Reverse Key Field Wireable Connector
RA05F200P0000000 PG 9 Cable Gland

M12 Straight 5 Pin Female Reverse Key Field Wireable Connector


RC05F200P0000000 PG 9 Cable Gland

M12 Reverse Key B-Coded Terminating Resistor


M12 Straight 5 Pin Male Reverse Key Terminating Resistor
RA05TR0000000000 Male

M12 Reverse Key B-Coded (Male View)


Cable - Pin Out/Color Code

Technical Data Cable RJ45 Field Attachable M12 Field Attachable


Body = Nickel Plated Zinc
Molded Body/Insert TPU TR = TPU
Insert = PA 66
Coupling Nut Nickel Plated Zinc Nickel Plated Zinc or Brass Nickel Plated Brass
Cable Jacket Material PUR N/A N/A
Cable O.D. 7.4 mm N/A 8.5 mm Max.
Voltage Rating (Nominal) 250 Volts 60 Volts 60 Volts
Current Rating 4.0 Amps 4.0 Amps 4.0 Amps
Degree of Protection IP65 (mated) IP65 (mated) IP 65 (mated)
Operating Temperature -20 C to 80 C (-4 F to 176 F) -10 C to 60 C (14 F to 140 F) -40 C to 85 C (-40 F to 185 F)
Conductor Gauge 24 AWG N/A 18 AWG Maximum
Bend Radius Cable = 78mm N/A N/A
Wire Connection N/A N/A Screw Terminal

53
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics G3 ETHERCAT CABLES
& CONNECTORS

M12 D-Coded Cables


M12 Straight 4 Pin Male D-Coded Single Ended Cable
QA0405MT00000000 5 Meter
QA0410MT00000000 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable


QA0405MT0QA04000 5 Meter
QA0410MT0QA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable


QA0405MT0VA04000 5 Meter
QA0410MT0VA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor


QA04D2MK0VC04000 0.2 Meter

M12 D-Coded Field Attachable Connectors


M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 PG 9 Cable Gland Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC


QA04F200R000071N PG 9 Cable Gland IDC

RJ45 Field Attachable Connector


RJ45 Field Wireable Connector with IDC
VA08F200R000071N PG 9 Cable Gland (1658435)

4 3 1 YE
M12 D-Coded Cable - 2 WH
(Male View)
Pin Out/Color Code 3 OG

1 2 4 BU

Technical Data Cable RJ45 Field Wireable M12 Field Attachable


Molded Body/Insert TPU/PE Housing = PA Carrier = PC Nickel Plated Zinc/PA 66
Coupling Nut Nickel Plated Zinc NA Nickel Plated Brass
Cable Jacket Material PVC NA NA
Cable O.D. 6.5mm Accepts 4.5 to 8.0mm Accepts 4.0 to 8mm
Voltage Rating (Nominal) 250 Volts NA 60 Volts
Current Rating 4.0 Amps 1.75 Amps Screw 4.0 Amps IDC 1.75 Amps
Degree of Protection IP65 (mated), RJ45 IP20 IP20 IP 65 (mated)
Operating Temperature -40 C to 70 C (-40 F to 158 F) -10 C to 60 C (14 F to 140 F) -40 C to 85 C (-40 F to 185 F)
Conductor Gauge 22 & 24 AWG 22 AWG Solid/Stranded Screw 24-18 AWG IDC 26-22 AWG
Bend Radius Minimum 19.5mm (fixed) 45.5mm (Flexible) NA NA
Wire Connection NA IDC Screw Terminal, IDC

54
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3 ETHERNET/IP-
ETHERNET/IP DLR & G3
MODBUS TCP/IP CABLES Electronics
& CONNECTORS

M12 D-Coded Cables

M12 Straight 4 Pin Male D-Coded Single Ended Cable


QA0405MK00000000 5 Meter
QA0410MK00000000 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable


QA0405MK0QA04000 5 Meter
QA0410MK0QA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable


QA0405MK0VA04000 5 Meter
QA0410MK0VA04000 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor


QA04D2MK0VC04000 0.2 Meter

M12 D-Coded Field Wireable Connectors

M12 Straight 4 Pin Male D-Coded Field Wireable Connector


QA04F20000000000 PG 9 Cable Gland Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC


QA04F2000000071N PG 9 Cable Gland Screw Terminal

RJ45 Field Wireable Connector

RJ45 Field Wireable Connector with IDC


VA08F2000000071N PG 9 Cable Gland

M12 D-Coded Cable -


(Male View)
Pin Out/Color Code

Technical Data Cable RJ45 Field Wireable M12 Field Attachable


Molded Body/Insert TPU, PA, PA66 Housing = PA Carrier = PC Body = Nickel Plated Zinc Insert = PA 66
Coupling Nut Nickel Plated Zinc or Brass NA Nickel Plated Brass
Cable Jacket Material PUR or PVC NA NA
Cable O.D. 0.67 to 8.0mm 4.5 to 8.0mm 6.0 to 8.0mm
Voltage Rating (Nominal) 42 Volts NA 60 Volts
Current Rating 1.5 Amps 1.75 Amps Screw 4.0 Amps IDC 1.75 Amps
Degree of Protection IP65 (mated) IP20 IP 65 (mated)
Operating Temperature -20 C to 60 C (-4 F to 140 F) -20 C to 70 C (-4 F to 158 F) -40 C to 85 C (-40 F to 185 F)
Conductor Gauge 26 & 24 AWG 26-22 AWG Solid/Stranded Screw 24-18 AWG IDC 26-22 AWG
Bend Radius 40mm NA NA
Wire Connection NA IDC IDC, Screw Terminal

55
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics G3 CC-LINK IE FIELD
CABLES & CONNECTORS

M12 X-Coded Cables

M12 Straight 8 Pin Male Single Ended Cable - Shielded


XA0905MR0000071P 5 Meter
XA0910MR0000071P 10 Meter

M12 Straight 8 Pin Male Double Ended Cable - Shielded


XA0905MR0EA0971P 5 Meter
XA0910MR0EA0971P 10 Meter

M12 Straight 8 Pin Male to Male RJ45 Cable - Shielded


XA0905MR0VA0971P 5 Meter
XA0910MR0VA0971P 10 Meter

M12 X-Coded Field Wireable Connector

M12 Straight 8 Pin Male Field Wireable Connector with IDC


XA09F2000000081E PG 9 Cable Gland

RJ45 Field Wireable Connector

RJ45 Field Wireable Connector with IDC


VA09F2000000071N PG 9 Cable Gland

M12 X-Coded Cable -


(Male View)
Pin Out/Color Code

Technical Data Cable M12 Field Wireable RJ45 Field Wireable


Molded Body/Insert TPU/PE Nickel Plated Zinc/PP Housing = PA Carrier = PC
Coupling Nut Nickel Plated Zinc Nickel Plated Zinc NA
Cable Jacket Material PUR NA NA
Cable O.D. 6.4mm Accepts 4.0 to 8.0mm Accepts 4.5 to 8.0mm
Voltage Rating (Nominal) 48 Volts 48 Volts 50 Volts
Current Rating 0.5 Amps 0.5 Amps 1.75 Amps
Degree of Protection IP65 (mated) IP65 (mated) IP 65 (mated)
Operating Temperature -20 C to 80 C (-4 F to 176 F) -40 C to 85 C (-40 F to 185 F) -40 C to 70 C (-40 F to 158 F)
Conductor Gauge 26 AWG 26 AWG 26-24 AWG
Bend Radius 51.2mm NA NA
Wire Connection NA IDC IDC

56
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
G3 I/O CABLES Electronics
& CONNECTORS

I/O Cables with SPEEDCON Connector Technology

M12 Straight 4 Pin Male Single Ended Cable, Euro Color Code
TA04E5MIE000071P 1.5 Meter
TA0403MIE000071P 3 Meter
TA0405MIE000071P 5 Meter

M12 90 4 Pin Male Single Ended Cable, Euro Color Code


TB04E5MIE000071P 1.5 Meter
TB0403MIE000071P 3 Meter
TB0405MIE000071P 5 Meter

M12 Straight 4 Pin Male to Female Cable Extension


TC04E5MIETA0471P 1.5 Meter
TC0403MIETA0471P 3 Meter

M12 Straight 3 Pin Male to M8 3 Pin Straight Female Extension


TC03E5MIEPA0371P 1.5 Meter
TC0303MIEPA0371P 3 Meter

I/O Connectors

M12 Straight 4 Pin Male Field Wireable Connector, IDC Connection


TA04F2000000081E PG 9 Cable Gland w/SPEEDCON connector technology

M12 Straight 4 Pin Male Field Wireable Connector, Screw Terminal


TA04F10000000000 PG 7 Cable Gland
TA04F20000000000 PG 9 Cable Gland

M12 90 4 Pin Male Field Wireable Connector, Screw Terminal


TB04F10000000000 PG 7 Cable Gland
TB04F20000000000 PG 9 Cable Gland

I/O Splitters

M12 to M12 Y Splitter, 21mm Spacing


TA0500000JC05000

M12 to M8 Y Splitter
TA0400000KC03000

57
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

M12 Cable Splitter, 2 Straight M12 Female Connectors


TA04D3MIEJC04000 0.3 Meter
TA04E5MIEJC04000 1.5 Meter
TA0403MIEJC04000 3.0 Meter

M12 Cable Splitter, 2 Straight M8 Female Connectors


TA04D3MIEKC03000 0.3 Meter
TA04E5MIEKC03000 1.5 Meter
TA0403MIEKC03000 3.0 Meter

Wire Stripper Tool


140-1097

I/O Cable Connector Pin Out Diagrams


M12 Cable - Pin Out/Color Code M12 Cable - Pin Out/Color Code M12 Cable - Pin Out/Color Code
TA04XXMIE0000000, TC03XXMIEPA0371P TC03XXMIEPA0371P
TB04XXMIE0000000 (Male to Female View) (Male to Female View)
(Male View)

M12 to M12 "Y" Splitter - Pin Out M12 to M8 "Y" Splitter - Pin Out M12 Field Wireable (IDC) - Pin Out
TA0500000JC05000 TA0400000KC03000 TA04F2000000081E (SPEEDCON)
(Male to Female View) (Male to Female View) (Male View)

M12 to M12 Cable Splitter - Pin Out M12 to M8 Cable Splitter - Pin Out Note:
XX denotes allowable length.
TA04XXMIEJC04000 TA04XXMIEKC03000 See pages 56 & 57.

(Male to Female View) (Male to Female View)

58
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Cable and Connector Technical Data


Technical Data M12 Cables M12/M8 Cables M12 Connectors
Molded Body/Insert TPU TPU Polyamide (or) PA 66
Coupling Nut Nickel Plated Zinc Nickel Plated Zinc Nickel Plated Zinc
Cable Jacket Material PUR PUR NA
PG7 4.0 to 6.0mm
Cable O.D. 4.70mm 4.70mm
PG9 4.0 to 8.0mm
Voltage Rating 250 Volts 60 Volts 50 Volts
Current Rating (Cond.) 4.0 Amps 3.0 Amps 4.0 Amps
Degree of Protection IP65 (mated) IP65 (mated) IP67 (mated)
-25 C to 80 C (-13 F to 176 F) -25 C to 80 C (-13 F to 176 F)
Operating Temperature -25 C to 80 C (-13 F to 176 F)
(fixed instl.) (fixed instl.)
Conductor Gauge 22 AWG 22 AWG 22 AWG Min. 18 AWG Max.
Bend Radius 47mm 47mm NA

Technical Data I/O "Y" Splitter I/O Cable Splitter


Molded Body/Insert TPU TPU
Coupling Nut Nickel Plated Zinc Nickel Plated Zinc
Cable Jacket Material NA PUR
Cable O.D. NA 4.40mm
Voltage Rating 60 Volts 60 Volts
Current Rating (Cond.) 3.0 Amps 3.0 Amps
Degree of Protection IP67 (mated) IP67 (mated)
Operating Temperature -25 C to 90 C (-13 F to 194 F) -25 C to 80 C (-13 F to 176 F)
Conductor Gauge NA 22 AWG or 24 AWG
Bend Radius NA 44mm

Technical Data Wire Stripper


Use with PVC Insulation
Stripping Range 28 AWG to 10 AWG
Cutting Range (Flexible) 10 AWG
Cutting Range (Rigid) 12 AWG

59
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics SUB-BUS CABLES
& CONNECTORS

Sub-Bus Cables

M12 Straight 5 Pin Male to Female Sub-Bus Cable - Shielded


TA0501MGDTC0571P 1 Meter
TA0505MGDTC0571P 5 Meter
TA0510MGDTC0571P 10 Meter

M12 Straight 5 Pin Female FIELD WIREABLE CONNECTOR, SPRING


CAGE
TC05F2000000071V PG9 Cable Gland

M12 Straight 5 Pin Male FIELD WIREABLE CONNECTOR,


SPRING CAGE
TA05F2000000071V PG9 Cable Gland

M12 90 5 Pin Female FIELD WIREABLE CONNECTOR,


SPRING CAGE
TD05F2000000071V PG9 Cable Gland

M12 90 5 Pin male FIELD WIREABLE CONNECTOR,


SPRING CAGE
TB05F2000000071V PG9 Cable Gland

Bulk Sub-Bus Cable *Note

000550MGD0005000 50 Meter Length


0005A0MGD0005000 100 Meter Length

* Note:
Length of field wired cables should not exceed the maximum length of 30 meters for total sub-
bus communications link. See appropriate technical manual for Sub-Bus length requirements.
The cable assemblies and Bulk cable are the only approved cables for the G3 Sub-Bus link.
See technical document TDG3SBWD1-0EN for proper installation and wiring of field wireable
connectors.

Technical Data
Technical Data Cable Connectors Bulk Cable
Molded Body / Insert TPU Zinc - Nickel Plated N/A
Coupling Nut Zinc - Nickel Plated Brass - Nickel Plated N/A
Cable Jacket Material PUR N/A Gray RAL 7001
Cable O.D. 6.70mm N/A 6.70mm
Voltage Rating (Nominal) 60 Volts 60 Volts 60 Volts
Current Rating 4.0 Amps 4.0 Amps 4.0 Amps
Degree of Protection IP65 (mated) IP65 (mated) IP65 (terminated)
Operating Temperature -40 C to 80 C (-40 F to 176 F) -40 C to 80 C (-40 F to 176 F) -20 C to 75 C (-4 F to 167 F)
24 AWG Signal 24 AWG Signal
Conductor Gauge 26-20 AWG
22 AWG Power 22 AWG Power
Bend Radius 67mm N/A 67mm
No. of Bending Cycles 5 Million N/A 5 Million

60
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
G3
Electronics

Example Sub-Bus Layout and Cabling (DeviceNet/CANopen Network)

Power Supply

Cable Description Example Cable Part # Page


Power Cable MC0405MAC0000000 47
DeviceNet/CANopen Communication Cable MC0505MGD0000000 50
Sub-Bus Cable TA0501MGDTC0571P 59
Alternate Sub-Bus Power Option TA0401MA0MC0471T 48
I/O Field Wireable Connector TA04F2000000081E 56
I/O Connector with Molded Cable TA0405MIE000071P 56

61
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.
World Headquarters
USA - Numatics, Incorporated Canada - Numatics, Ltd Mxico - Ascomatica SA de CV Brazil - Ascoval Ind.e Comercio Ltda
46280 Dylan Drive P: 519-758-2700 P: 52 55 58 09 56 40 (DF y Area metropolitana) P: (55) 11-4208-1700
Novi, Michigan 48377 F: 519-758-5540 P: 01 800 000 2726 (Interior de la Repblica) F: (55) 11-4195-3970
F: 52 55 58 09 56 60
P: 248-596-3200
F: 248-596-3201
LT-G3Catalog2.5 Rev 06/16
1M-Walsworth-4/14
Numatics Inc. 2012-2016

ASCO | Tel (248) 596-3200 | www.asco.com | email: an.insidesales@emerson.com Numatics is registered in the United States and elsewhere

You might also like