Ind 03
Ind 03
Ind 03
The noble metal platinum thermocouple elements illustrated on this catalog page are replacement elements for use in
Pyromation's complete high temperature industrial thermocouple assemblies as found elsewhere in this catalog section.
These replacement elements are also compatible for use in other manufacturers' high temperature thermocouple assem-
blies. All insulated elements are supplied with high temperature alumina insulators and are available with the options as
listed below. Element types R, S, and B are supplied with a fusion weld. Custom designed constructions are available.
1 1/2" 2"
X X Nominal
Nominal
Note: Elements supplied without collars are intended to be Note: Elements supplied with collars are intended to be used
used with ceramic tubes that are not supplied with hex fittings with ceramic tubes with hex fittings as shown on page IND-7
as shown on page IND-7
1 2 3 4
I
EXAMPLE ORDER NUMBER: R24 I
I
I
R - 18 - 3
1 4
SINGLE STRAIGHT ELEMENT TYPE ELEMENT OPTIONS
ORDER CODE ORDER
TYPE and WIRE GAUGE ELEMENT MATERIAL CODE DESCRIPTION
2 3
ELEMENT INSULATION ELEMENT "X" LENGTH
INSULATOR ORDER ORDER
DIMENSIONS CODE LENGTH CODE LENGTH
ORDER INSULATOR WIRE (INCHES)
CODE DESCRIPTION GAUGE SINGLE and DUPLEX 12 12 Inches 30 30 Inches
0 Uninsulated Bare None 18 18 Inches 36 36 Inches
Element
24 24 Inches Specify Other Lengths
R Round, 99.7% 24 .188 OD w/.535
Alumina Insulator OD Collar
(4-hole, single and 26 .188 OD w/.535
duplex) 3400F OD Collar
maximum temp.
ELEMENT OPTIONS
ORDER
CODE DESCRIPTION
M Reference grade (consult factory for other types)