L7/L18 commissioning and integration with FXED

7/25/2016 Work instruction For internal use Nokia 2016

1 / 55
Contents
1 Purpose ........................................................................................................................4

2 Prerequisites ................................................................................................................5

2.1 HW ................................................................................................................................5

2.1.1 HW for site build configurations ..................................................................................5

2.1.2 Additional HW for 3CC CA configuration .....................................................................8

2.2 SW ................................................................................................................................9

2.3 L7/L18 frequency allocation .......................................................................................10

2.4 XML Commissioning Files.............................................................................................10

3 L7/L18 connectivity diagram ......................................................................................11

4 L18 RF tails connections for distributed 2T4R configuration.....................................17

4.1 RF tails connections for distributed 2T4R L18 with 2 x FXED ....................................18

4.2 RF tails connections for distributed 2T4R L18 with 1 x FXED per sector ..................19

5 RF tails connections for 2T2R L7 configuration ..........................................................20

6 RF tails connections for 2T4R L7 configuration with 2xFRPA .....................................21

7 3CC CA FSMFs Interconnection Cable Installation ......................................................22

7.1 SRIO Cable Installation.................................................................................................22

7.2 HDMI Synchronisation Cable Installation.....................................................................23

8 Commissioning.............................................................................................................24

8.1 Power on FSMF and all RF modules .............................................................................24

8.2 Connect to site with BTS Site Manager .......................................................................24

8.3 SW upgrade from RL40 1.2 to RL60 1.1 (LN6.0_ENB_1311_764_08) ........................26

8.4 SW upgrade from RL60 1.1 to RL70 2.3.1 (LN7.0_ENB_1407_586_18) .....................27

8.5 Commissioning TRS only ..............................................................................................28

8.6 RF units detection........................................................................................................29

8.7 BTS Site commissioning steps.....................................................................................30

8.7.1 Introduction .................................................................................................................30

8.7.2 L18 MHA commissioning .............................................................................................32

7/25/2016 Work instruction For internal use Nokia 2016

2 / 55
8.7.3 L7 MHA commissioning................................................................................................32

8.7.3.1 L7 Antenna Line Management.....................................................................................33

8.7.3.2 L7 AISG MHA settings ..................................................................................................36

8.7.3.3 L7 AISG MHA settings ..................................................................................................39

8.7.4 Send Parameters .........................................................................................................44

8.7.5 Additional Site Settings................................................................................................44

8.7.6 Site Testing ..................................................................................................................45

8.7.7 Commissioning Report ................................................................................................47

8.8 Retrieve certificate ......................................................................................................48

8.9 Commissioning completed ..........................................................................................50

9 Check L7 & L18 Cell RSSI level .....................................................................................51

10 Test call ........................................................................................................................52

10.1 L18 testing ...................................................................................................................52

10.2 L7 testing .....................................................................................................................53

11 References ...................................................................................................................54

11.1 4G LTE bands ...............................................................................................................54

11.2 SFP modules used in L7/L18/L23/L26 eNB ...............................................................54

11.3 FSMF LMP connector pin map .....................................................................................55

7/25/2016 Work instruction For internal use Nokia 2016

3 / 55
1 Purpose
This document describes the work instructions of commissioning and integration of Nokia LTE
FDD LTE700/LTE1800 eNB with FXED.
Following configurations are covered:
Baseband: 1xFSMF + 1xFBBA + 1xFBBC or 1xFSMF + 1xFBBC + 1xFBBC
Radio:
- 3xFXED+1xFRPA L18 distributed 2T4R+L7 stacked 2T2R
- 3xFXED+3xFRPA Fully Distributed, L7 and L18 2T4R
- 2xFXED+1xFRPA L18 stacked 2T4R+L7 stacked 2T2R
- 1xFXED+1xFRPA L18 stacked 2T2R+L7 stacked 2T2R
- 1xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R
- 2xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R
- 3xFXED+2xFRPA L18 distributed 2T2R/2T4R+L7 stacked 2T4R
L7 1+1+1 @ 40W 10MHz bandwidth
L18 1+1+1 @ 60W 15MHz bandwidth
eNB software RL70 2.3.1

7/25/2016 Work instruction For internal use Nokia 2016

4 / 55
2 Prerequisites
Ensure that health and safety regulations are observed at any given time during the site build.
The weight of the RF unit is close to 25 kg. As such two man lift is recommended.

2.1 HW

HW requirement includes two parts.

- HW for site build configurations


- Additional HW for 3CC CA configuration

2.1.1 HW for site build configurations

The following main HW components are required for the different configurations.

All L7/L18 dual sites require 2xFBBC or 1xFBBA+1xFBBC, and the second BB
extension card has to be FBBC.
It is highly recommended to use only FSMF with 2xFBBC cards in greenfield
deployment.
Please ensure FRPA 1/2/3 are connected to ports RF1/2/4 respectively on
the second FBBC.
1. 3xFXED+1xFRPA L18 distributed 2T4R+L7 stacked 2T2R

HW component Quantity
FSMF 1
FBBC* 2
FPFD** 1
FRPA 1
FXED 3
FOSI*** 6 (FXED FSMF)
FOSH**** 2 (FRPA FSMF)
Single mode Optic
3 (FXED FSMF)
Fibre*****
Multi-mode Optic
1 (FRPA FSMF)
Fibre******
1000Base-T Ethernet
1
Cat6 cable

7/25/2016 Work instruction For internal use Nokia 2016

5 / 55
2. 3xFXED+3xFRPA Fully Distributed, L7 and L18 2T4R

HW component Quantity
FSMF 1
FBBC* 2
FPFD** 1
FRPA 3
FXED 3
FOSI*** 6 (FXED FSMF)
FOSH**** 6 (FRPA FSMF)
Single mode Optic
3 (FXED FSMF)
Fibre*****
Multi-mode Optic
3 (FRPA FSMF)
Fibre******
1000Base-T Ethernet
1
Cat6 cable

3. 2xFXED+1xFRPA L18 stacked 2T4R+L7 stacked 2T2R

HW component Quantity
FSMF 1
FBBC* 2
FPFD** 1
FRPA 1
FXED 2
FOSI*** 8 (FXED FSMF)
FOSH**** 2 (FRPA FSMF)
Single mode Optic
4 (FXED FSMF)
Fibre*****
Multi-mode Optic
1 (FRPA FSMF)
Fibre******
1000Base-T Ethernet
1
Cat6 cable

4. 1xFXED+1xFRPA L18 stacked 2T2R+L7 stacked 2T2R


Note: this configuration should only be considered if antenna line does not support 4 way
Rx diversity on L18.

HW component Quantity
FSMF 1
FBBC* 2

7/25/2016 Work instruction For internal use Nokia 2016

6 / 55
FPFD** 1
FRPA 1
FXED 1
FOSI*** 4 (FXED FSMF)
FOSH**** 2 (FRPA FSMF)
Single mode Optic
2 (FXED FSMF)
Fibre*****
Multi-mode Optic
1 (FRPA FSMF)
Fibre******
1000Base-T Ethernet
1
Cat6 cable

5. 1xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R

HW component Quantity
FSMF 1
FBBC* 2
FPFD** 1
FRPA 2
FXED 1
FOSH*** 8
Multi-mode Optic
4
Fibre***
1000Base-T Ethernet
1
Cat6 cable

6. 2xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R

HW component Quantity
FSMF 1
FBBC* 2
FPFD** 1
FRPA 2
FXED 4
12 (RF units to
FOSH***
FSMF/FBBx)
Multi-mode Optic 6 (RF units to
Fibre***** FSMF/FBBx)
1000Base-T Ethernet
1
Cat6 cable

7. 3xFXED+2xFRPA L18 distributed 2T2R/2T4R+L7 stacked 2T4R

HW component Quantity

7/25/2016 Work instruction For internal use Nokia 2016

7 / 55
FSMF 1
FBBC* 2
FPFD** 1
FRPA 2
FXED 3
FOSI*** 6 (FXED FSMF)
FOSH**** 4 (FRPA FSMF)
Single mode Optic
3 (FXED FSMF)
Fibre*****
Multi-mode Optic
2 (FRPA FSMF)
Fibre******
1000Base-T Ethernet
1
Cat6 cable

* Optional use of FBBA+FBBC is allowed.

** FPFD is a preferred piece of equipment. If not available DC power for RF units needs to be
prepared independently. In partially stacked (L7) and partially distributed (L18) build FPFD would
provide power only to stacked L7 RF modules.

*** Note: Thepreferred build should be based on FOSI SFPs. If a FOSA or FOSG is already installed
and alternation to the existing L18 build is not possible Optus Project Manager needs to approve
build with SFPs other than FOSI. Note fibre check needs to also be run to match the SFP type with
the single mode or multi-mode fibre used on site.

**** Note: FOSI and SM links are also possible.


***** Note: IfFOSI (or FOSA) are used SM fibre is required. If FOSG are used MM fibre is needed
****** Note: MM fibre is preferred with FOSH. SM with FOSI is also possible

2.1.2 Additional HW for 3CC CA configuration

Below two cables need to be installed between collocated LTE FDD and LTE TDD sites in order to
enable Downlink Carrier Aggregation 3CC.
SRIO Link between collocated modules of paired FDD and TDD sites
HDMI cable between TDD Sync Out and FDD Sync In ports

Module / Item Name Description Qty


FBBC Nokia Flexi Baseband Extension 1
Module

7/25/2016 Work instruction For internal use Nokia 2016

8 / 55
FOSH Optical SFP H 850nm 6GBps 300m 2
Multi Mode
Multimode Fibre Note: Only one fibre cable required 1
Cable per site to be installed. Below is the
Nokia SRIO cable length option:
FSFO Flexi System Fibre HF 2m, MM See above note
FSFD Flexi System Fibre D 4m, MM See above note
FSFF Flexi System Fibre F 10m, MM See above note
FSFG Flexi System Fibre G 20m, MM See above note
HDMI Sync Cable Note: only one HDMI Sync cable 1
required to be installed between
1800 FSMF and 2300 FSMF. Below is
the Nokia HDMI cable length option
FTSF Sync Cable F, 2m HDMI to HDMI both See above note
with IP boot protection
FTSP Sync Cable F, 5m HDMI to HDMI both See above note
with IP boot protection
FTSQ Sync Cable F, 10m HDMI to HDMI both See above note
with IP boot protection
FTQR Sync Cable F, 15m HDMI to HDMI both See above note
with IP boot protection
FTSO Sync Cable O, 25m HDMI to HDMI See above note
both with IP boot protection

Please refer to Chapter 7 for 3CC Cabling.

2.2 SW

The final software RL70 2.3.1 will be used in L7/L18 dual band site with FXED.
New FSMF is delivered with preinstalled LN4.0 1.2 (LN4.0 ENB 1202_781_57) SW or FDSW 1.0
(boot-loader).
Upgrade paths:
RL40 1.2 (LN4.0_ENB_1202_781_57) RL60 1.1 (LN6.0_ENB_1311_764_08) RL70 2.3.1
(LN7.0_ENB_1407_586_18)
FDSW1.0_RP_FD1405_284_00 RL70 2.3.1 (LN7.0_ENB_1407_586_18)

Ensure all Software listed is available prior to Installation and Commissioning.

7/25/2016 Work instruction For internal use Nokia 2016

9 / 55
RL70 2.3.1

Software Software Version


Nokia FDD LTE BTS Software LN7.0_ENB_1407_586_18
Nokia FDD LTE BTS Element Manager LN7.0_BTSSM_1407_121_00

RL60 1.1

Software Software Version


Nokia FDD LTE BTS Software LN6.0_ENB_1311_764_08
Nokia FDD LTE BTS Element Manager LN6.0_BTSSM_1311_097_00

2.3 L7/L18 frequency allocation

Below table shows frequency allocation for Optus L7 and L18.

L7 EARFCN Frequency Bandwidth


Downlink 9260 763.0 MHz 10 MHz
Uplink 27260 708.0 MHz

L18 EARFCN Frequency Bandwidth


Downlink 1725 1857.5 MHz 15 MHz
Uplink 19725 1762.5 MHz

2.4 XML Commissioning Files

L7+L18 XML site commissioning template file will be distributed by Nokia RIC.

7/25/2016 Work instruction For internal use Nokia 2016

10 / 55
3 L7/L18 connectivity diagram
Please follow the below diagrams to connect optical fibres between RF modules and system module
according to site configuration.

1. Standard cabling for 3xFXED+1xFRPA L18 distributed 2T4R+L7 stacked 2T2R

Connect RF/EXT1 port on FSMF to Opt 1 port on FXED1 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT2 port on FSMF to Opt 1 port on FXED2 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT3 port on FSMF to Opt 1 port on FXED3 (Single Mode OBSAI link with FOSI SFPs)
Connect RF1 port on FBBC2 to Opt 1 port on FRPA (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.

Picture 1 - 3xFXED+1xFRPA L18 distributed 2T4R+L7 stacked 2T2R


2. Standard cabling for 3xFXED+3xFRPA Fully Distributed, L7 and L18 2T4R

Connect RF/EXT1 port on FSMF to Opt 1 port on FXED1 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT2 port on FSMF to Opt 1 port on FXED2 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT3 port on FSMF to Opt 1 port on FXED3 (Single Mode OBSAI link with FOSI SFPs)

7/25/2016 Work instruction For internal use Nokia 2016

11 / 55
Connect RF1 port on FBBC2 to Opt 1 port on FRPA1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF2 port on FBBC2 to Opt 1 port on FRPA2 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF4 port on FBBC2 to Opt 1 port on FRPA3 (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.


Note: FBBC2 port3 should not be used to connect RRUs.

Picture 2 - 3xFXED+3xFRPA Fully Distributed, L7 and L18 2T4R

3. Standard cabling for 2xFXED+1xFRPA L18 stacked 2T4R+L7 stacked 2T2R


Connect RF/EXT1 port on FSMF to Opt 1 port on FXED1 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT2 port on FSMF to Opt 2 port on FXED1 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT3 port on FSMF to Opt 1 port on FXED2 (Single Mode OBSAI link with FOSI SFPs)
Connect RF3 port on FBBC1 to Opt 2 port on FXED2 (Single Mode OBSAI link with FOSI SFPs)
If FBBA is used instead of FBBC1: Connect RF port on FBBA to Opt 2 port on FXED2 (Single Mode OBSAI link
with FOSI SFPs)
Connect RF1 port on FBBC2 to Opt 1 port on FRPA (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA units need to be connected to the second FBBC.

7/25/2016 Work instruction For internal use Nokia 2016

12 / 55
Picture 3 - 2xFXED+1xFRPA L18 stacked 2T4R+L7 stacked 2T2R

4. Standard cabling for 1xFXED+1xFRPA L18 stacked 2T2R+L7 stacked 2T2R


Connect RF/EXT1 port on FSMF to Opt 1 port on FXED (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT2 port on FSMF to Opt 2 port on FXED (Single Mode OBSAI link with FOSI SFPs)
Connect RF1 port on FBBC2 to Opt 1 port on FRPA (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.

7/25/2016 Work instruction For internal use Nokia 2016

13 / 55
Picture 4 - 1xFXED+1xFRPA L18 stacked 2T2R+L7 stacked 2T2R

5. 1xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R

Connect RF/EXT1 port on FSMF to Opt 1 port on FXED (Multi Mode OBSAI link with FOSH SFPs)
Connect RF/EXT2 port on FSMF to Opt 2 port on FXED (Mutli Mode OBSAI link with FOSH SFPs)

Connect RF1 port on FBBC2 to Opt 1 port on FRPA1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF2 port on FBBC2 to Opt 1 port on FRPA1 (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.

7/25/2016 Work instruction For internal use Nokia 2016

14 / 55
Picture 5 - 1xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R

6. 2xFXED+2xFRPA L18 stacked 2T2R+L7 stacked 2T4R


Connect RF/EXT1 port on FSMF to Opt 1 port on FXED1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF/EXT2 port on FSMF to Opt 2 port on FXED1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF/EXT3 port on FSMF to Opt 1 port on FXED2 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF3 port on FBBC1 to Opt 2 port on FXED2 (Multi Mode OBSAI link with FOSH SFPs)
If instead of FBBC1 and FBBA is used: Connect RF1 of FBBA to OPT2 port on FXED2 (Multi M ode OBSAI link
with FOSH SFPs)

Connect RF1 port on FBBC2 to Opt 1 port on FRPA1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF2 port on FBBC2 to Opt 1 port on FRPA2 (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.

7/25/2016 Work instruction For internal use Nokia 2016

15 / 55
Picture 6 - 2xFXED+2xFRPA L18 stacked 2T4R+L7 stacked 2T4R

7. 3xFXED+2xFRPA L18 distributed 2T2R/2T4R+L7 stacked 2T4R


Connect RF/EXT1 port on FSMF to Opt 1 port on FXED1 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT2 port on FSMF to Opt 1 port on FXED2 (Single Mode OBSAI link with FOSI SFPs)
Connect RF/EXT3 port on FSMF to Opt 1 port on FXED3 (Single Mode OBSAI link with FOSI SFPs)

Connect RF1 port on FBBC2 to Opt 1 port on FRPA1 (Multi Mode OBSAI link with FOSH SFPs)
Connect RF2 port on FBBC2 to Opt 1 port on FRPA2 (Multi Mode OBSAI link with FOSH SFPs)

Note: FRPA unit needs to be connected to the second FBBC.

7/25/2016 Work instruction For internal use Nokia 2016

16 / 55
Picture 7 - 3xFXED+2xFRPA L18 distributed 2T2R/2T4R+L7 stacked 2T4R

4 L18 RF tails connections for distributed 2T4R


configuration
Some plumbing diagrams show 4R requirement for L18. In this scenario, 4 x RF tails are needed.
Please follow below instructions to connect 4 RF tails between FXEDs and Quad-band combiners.
For example:

7/25/2016 Work instruction For internal use Nokia 2016

17 / 55
4.1 RF tails connections for distributed 2T4R L18 with 2 x FXED

The below diagram illustrates tails connections for stacked L18 at Sector 1.
Sector 2 and Sector 3 will follow same pattern to get tails connected.
Tails connections for distributed L18 with 2 x FXED:
FXED 1.1.1 Ant1 > 1800/2100/2300/2600 combiner A -> TX/RX Antenna High Band 1 H+ (+45)
FXED 1.1.1 Ant2 > 1800/2100/2300/2600 combiner C -> RX Antenna High Band 2 H+ (+45)
FXED 1.3.1 Ant1 > 1800/2100/2300/2600 combiner B -> TX/RX Antenna High Band 1 H- (-45)
FXED 1.3.1 Ant2 > 1800/2100/2300/2600 combiner D -> RX Antenna High Band 2 H- (-45)
Please note that Antenna High Band 3 and 4 may be allocated to Optus L18 at VHA lead site in
actual plumbing diagram.

7/25/2016 Work instruction For internal use Nokia 2016

18 / 55
4.2 RF tails connections for distributed 2T4R L18 with 1 x FXED per sector

The below diagram illustrates tails connections for distributed L18 at Sector 1.
Sector 2 and Sector 3 will follow same pattern to get tails connected.
Tails connections for distributed L18:
FXED Ant1 > 1800/2100/2300/2600 combiner A -> TX/RX Antenna High Band 1 H+ (+45)
FXED Ant2 > 1800/2100/2300/2600 combiner C -> RX Antenna High Band 2 H+ (+45)
FXED Ant3 > 1800/2100/2300/2600 combiner B -> TX/RX Antenna High Band 1 H- (-45)
FXED Ant4 > 1800/2100/2300/2600 combiner D -> RX Antenna High Band 2 H- (-45)
Please note that Antenna High Band 3 and 4 may be allocated to Optus L18 at VHA lead site in
actual plumbing diagram.

7/25/2016 Work instruction For internal use Nokia 2016

19 / 55
5 RF tails connections for 2T2R L7 configuration
Stacked L7 (FRPA in shelter)

Please follow below instruction to connect RF tails when FRPA is in shelter.

Sector 1: A feed is connected to FRPA Ant 1, and B feed is connected to FRPA Ant 2.
Sector 2: A feed is connected to FRPA Ant 3, and B feed is connected to FRPA Ant 4.
Sector 3: A feed is connected to FRPA Ant 5, and B feed is connected to FRPA Ant 6.

Distributed L7 (3xFRPA on monopole)

7/25/2016 Work instruction For internal use Nokia 2016

20 / 55
Please follow below instruction to connect tails when FRPAs are on monopole / roof.

Each L7 sector has its own FRPA.

A feed is connected to FRPA Ant 1, and B feed is connected to FRPA Ant 3 at all 3
sectors.

Note:

L7 FRPA has no internal Bias-T at Antenna port 2, 4 and 6. Those ports are DC short. DC / AISG bus will
be pulled down together with connected antenna line devices, if L7 FRPA port 2, 4 or 6 combines with
any feed from other technologies as current master of MHA / RET.

Recommendation is to separate A and B feeds, combining A feeds within one antenna line; B feeds
following a separate antenna line (feeders, combiners and ALD). DC should be then provided to MHA
via A feeds to avoid DC short.

Ensure that L7 A feed is going to same combiner with A feeds from other technologies, L7 B feed is
going to same combiner with B feeds from other technologies.

6 RF tails connections for 2T4R L7 configuration


with 2xFRPA
The below diagram illustrates tails connections for 2T4R L7 at Sector 1.
Sector 2 and Sector 3 will follow same pattern to get tails connected.
Tails connections for 2T4R L7 with 2 x FRPA:
FRPA 1 Ant1 > 700 MHA A port -> TX/RX Antenna Low Band 1 H+ (+45)
FRPA 1 Ant2 > 700/850/900 combiner A -> RX Antenna Low Band 2 H+ (+45)
FRPA 2 Ant1 > 700 MHA B port -> TX/RX Antenna Low Band 1 H- (-45)
FRPA 2 Ant2 > 700/850/900 combiner B -> RX Antenna Low Band 2 H- (-45)
Note:

7/25/2016 Work instruction For internal use Nokia 2016

21 / 55
DC stop may be required on FRPA 1 ANT 2 if 700/900 dual band or 700/850/900 tri -band MHA is
in use.

7 3CC CA FSMFs Interconnection Cable Installation


7.1 SRIO Cable Installation

Connect the multimode LC to LC optical cable to the both FSMF main SRIO ports as per shown
connection diagram below.

7/25/2016 Work instruction For internal use Nokia 2016

22 / 55
7.2 HDMI Synchronisation Cable Installation

Connect the HDMI cable from Sync Out port of the 2300 LTE TDD FSMF to the Sync IN port of the
1800 LTE FDD FSMF.
IMPORTANT: Ensure that the exact cable length and Nokia product code for the cable is recorded
and tracked with the site build documentation.

7/25/2016 Work instruction For internal use Nokia 2016

23 / 55
8 Commissioning
8.1 Power on FSMF and all RF modules

8.2 Connect to site with BTS Site Manager

1. Launch BTS Site Manager

2. Select Disable, then Close

7/25/2016 Work instruction For internal use Nokia 2016

24 / 55
3. New FSMF is delivered with preinstalled LN4.0 1.2 (LN4.0 ENB 1202_781_57) SW

7/25/2016 Work instruction For internal use Nokia 2016

25 / 55
8.3 SW upgrade from RL40 1.2 to RL60 1.1 (LN6.0_ENB_1311_764_08)

Upgrade SW by selecting Software and Update SW to BTS Site

Select Browse
Select LN6.0_ENB_1311_764_08_release_BTSSM_downloadable.zip
Select Open

7/25/2016 Work instruction For internal use Nokia 2016

26 / 55
Tick Activate SW after update box
Select Update

8.4 SW upgrade from RL60 1.1 to RL70 2.3.1 (LN7.0_ENB_1407_586_18)

Upgrade SW by selecting Software and Update SW to BTS Site


Select Browse
Select LN7.0_ENB_1407_586_18_release_BTSSM_downloadable.zip
Select Open

7/25/2016 Work instruction For internal use Nokia 2016

27 / 55
Tick Activate SW after update box
Select Update

8.5 Commissioning TRS only

If FRPA is connected to FSMF EIF2/RF/EXT 6, FSMF cant detect FRPA until TRS is commissioned
with Enable FSM EIF2 as RP3-01 interface ticked.

Choose Target - TRS only


Commissioning type - Planned
Select Commissioning file

7/25/2016 Work instruction For internal use Nokia 2016

28 / 55
Click Next
Continue with Send Parameters

8.6 RF units detection

Switch on RF units power and wait until RF modules are detected by system module.
The FRPA will show up as not commissioned.

If incompatible SW is detected, then perform a SW upgrade (reload the SW).

7/25/2016 Work instruction For internal use Nokia 2016

29 / 55
The same SW should be used as already running (LN7.0_ENB_1407_586_18).

Go to Software -> Update SW to BTS Site, choose


LN7.0_ENB_1407_586_18_release_BTSSM_downloadable.zip -> Update

8.7 BTS Site commissioning steps

8.7.1 Introduction
After the FRPA is detected start BTS Commissioning
Select BTS site (check both, BTS and TRS)
Select Template
Select Commissioning file and browse for the new L18+L7 xml commissioning file as received
from RIC

7/25/2016 Work instruction For internal use Nokia 2016

30 / 55
Continue with Next

7/25/2016 Work instruction For internal use Nokia 2016

31 / 55
8.7.2 L18 MHA commissioning

Please ensure MHAs are set properly according to plumbing


diagram.
Please call RIC to verify MHA settings after commissioning.
It is mandatory to fill in correct MHA product code and
serial number as per physical MHA in case MHA in use
option is configured. Cells may stay disabled if MHA
product code / serial number are left blank or filled in
with incorrect information.

Please follow attached document to find out MHA product code and serial number. Same steps
are applied to L18.

Steps to find MHA


Serial number and Product code.docx

8.7.3 L7 MHA commissioning

7/25/2016 Work instruction For internal use Nokia 2016

32 / 55
The following procedure is for L7 MHA commissioning.

Please call RIC to verify MHA settings after commissioning.


It is mandatory to fill in correct MHA product code and
serial number as per physical MHA in case MHA in use
option is configured. Cells may stay disabled if MHA
product code / serial number are left blank or filled in
with incorrect information.L7 Antenna Line Management
8.7.3.1 L7 Antenna Line Management

L18 Antenna Line Management settings remain unchanged. Therefore ensure the L1800 settings
are the same as prior the L700 FRPA radio module installation.

L7 Antenna Line Management should be set according to plumbing diagram.

Scenario 1:

- L700 tails are connected to triplexer in shelter. L700 is sharing same antenna line as U9 /
VHA 850. 700/900 dual band or 700/850/900 Tri band MHA is controlled by U9 / VHA
850.

Please refer to BALLAJURA plumbing diagram.

BALLAJURA.pdf

7/25/2016 Work instruction For internal use Nokia 2016

33 / 55
Enable DC voltage on FRPA Ant 1&3&5 and disable AISG on all FRPA Antenna ports

Scenario 2:

- L700 feeders are connected to 700 single band MHA.

Please refer to MIRRABOOKA plumbing diagram.

Enable DC voltage and enable AISG on FRPA Ant 1&3&5

7/25/2016 Work instruction For internal use Nokia 2016

34 / 55
Scenario 3:

- L700 FPRAs are installed on monopole / roof.

Please refer to Buranda North plumbing diagram.

B0178.pdf

Disable DC voltage and AISG on all FRPA Antenna ports

7/25/2016 Work instruction For internal use Nokia 2016

35 / 55
Continue with Next

8.7.3.2 L7 AISG MHA settings

L18 AISG MHA settings remain unchanged. Therefore ensure the L1800 settings are the same as
prior the L700 FRPA radio module installation.
Follow the below instructions for L7 AISG MHA settings.

Scenario 1:
- L700 tails are connected to triplexer in shelter. L700 is sharing same antenna line as U9 /
VHA 850. 700/900 dual band or 700/850/900 Tri band MHA is controlled by U9 / VHA
850.

7/25/2016 Work instruction For internal use Nokia 2016

36 / 55
AISG MHA Settings are not required.

Scenario 2:

- L700 feeders are connected to 700 single band MHA.

Select This BTS option and choose Antenna port accordingly

7/25/2016 Work instruction For internal use Nokia 2016

37 / 55
Scenario 3:

- L700 FPRAs are installed on monopole / roof.


AISG MHA Settings are not required.

Continue with Next

7/25/2016 Work instruction For internal use Nokia 2016

38 / 55
8.7.3.3 L7 AISG MHA settings

L18 Antenna Line Settings remain unchanged. Therefore ensure the L1800 settings are the same
as prior the L700 FRPA radio module installation.

Follow the below instructions for L7 Antenna Line Settings.

Scenario 1:
- L700 tails are connected to triplexer in shelter. L700 is sharing same antenna line as U9 /
VHA 850. 700/900 dual band or 700/850/900 Tri band MHA is controlled by U9 / VHA
850.

Settings:
Choose MHA in use and set MHA gain 13dB in all FRPA legs
MHA type is set to other
Please contact RIC to find out MHA serial number and product code for each sector.

7/25/2016 Work instruction For internal use Nokia 2016

39 / 55
7/25/2016 Work instruction For internal use Nokia 2016

40 / 55
7/25/2016 Work instruction For internal use Nokia 2016

41 / 55
Scenario 2:
- L700 feeders are connected to 700 single band MHA.

Change of Antenna Line Settings is not required

7/25/2016 Work instruction For internal use Nokia 2016

42 / 55
Scenario 3:

- L700 FPRAs are installed on monopole / roof with no MHA.

Keep default Antenna Line Settings for all FRPA legs


Change of Antenna Line Settings is not required

Continue with Next

7/25/2016 Work instruction For internal use Nokia 2016

43 / 55
8.7.4 Send Parameters

Continue with Send Parameters

8.7.5 Additional Site Settings


No need to change

Continue with Next

7/25/2016 Work instruction For internal use Nokia 2016

44 / 55
8.7.6 Site Testing
Site tests -> press Test,

Then select Normal and Start.

Wait around 12 sec until all tests are completed.

7/25/2016 Work instruction For internal use Nokia 2016

45 / 55
Check test results and if all are Pass, then continue with Next

7/25/2016 Work instruction For internal use Nokia 2016

46 / 55
8.7.7 Commissioning Report
Save the BTS Commissioning Report

Select the desired location and change the File name if required.
Continue with Save, then with Finish

7/25/2016 Work instruction For internal use Nokia 2016

47 / 55
8.8 Retrieve certificate

1. Select IP -> Navigate to tab Application Addresses


Make sure to take a note of the original Management plane IP address before changing it.
Select VLAN interface IP as Management plane

Click Send

2. Then perform site reset manually

7/25/2016 Work instruction For internal use Nokia 2016

48 / 55
3. Check if certificate has been successfully retrieved

Select Configuration -> Certificate Management

Make sure BTS certificate appear in tab BTS Certificates

4. Change Management plane IP back to the original and click Send

7/25/2016 Work instruction For internal use Nokia 2016

49 / 55
5. Perform site reset manually

8.9 Commissioning completed

After successful BTS commissioning the site status should be


OAM connected
On air
TRS commissioned

7/25/2016 Work instruction For internal use Nokia 2016

50 / 55
9 Check L7 & L18 Cell RSSI level
BTS PM will be available in 15 minutes after cell is unlocked.
RSSI_PUCCH_AVG and RSSI_PUSCH_AVG need to be checked from BTS Site Manager.
RSSI_PUCCH_AVG
RSSI_PUCCH_AVG should be between -108 dBm and -102 dBm.
If RSSI_PUCCH_AVG is out of the range, please contact RIC for troubleshooting.
e.g. Local cell 49

RSSI_PUSCH_AVG
RSSI_PUSCH_AVG should be between -115 dBm and -102 dBm.
If RSSI_PUSCH_AVG is out of the range, please contact RIC for troubleshooting.
e.g. Local cell 49

7/25/2016 Work instruction For internal use Nokia 2016

51 / 55
10 Test call
10.1 L18 testing

Lock UE (Samsung) to LTE network


Type: *#2263#
Select [4] LTE Band Preference
Select [5] LTE B3 in L1800 case
Type: *#0011# to check EARFCN & PCI value

Start call tests. Unlock one sector at a time and record the downlink and uplink throughput. Als o
make a note of the Round trip time.

Each LTE1800 Sector should offer up to 100Mbit/s downlink and 30Mbit/s uplink speeds.

7/25/2016 Work instruction For internal use Nokia 2016

52 / 55
10.2 L7 testing

The L7 testing is required after L700 integration.

Please follow attached testing instruction and fill in test result form.

L700-Testing
document.docx

Sector 1 Sector 2 Sector 3


RSRP PCI SNR RSRP PCI SNR RSRP PCI SNR
-61 346 30 -59 347 30 -62 345 30
Att.
Test Items Att. 1 2 Att. 3 Att. 1 Att. 2 Att. 3 Att. 1 Att. 2 Att. 3
DL TP (Mbps) 71.34 71 69.87 70.23 70.48 70.04 69.25 70.17 69.98
UL TP (Mbps) 20.54 20 20.31 19.51 20.09 19.41 19.99 19.23 19.48
Latency (ping, ms) 22.7 21.2 20.1 19.9 20.8 25 21.1 26.7 17.9
FD-LTE 4G to FD-LTE
4G- Call OK OK OK OK OK OK OK OK OK
FD-LTE 4G to 3G- Call OK OK OK OK OK OK OK OK OK
SMS OK OK OK OK OK OK OK OK OK
MMS OK OK OK OK OK OK OK OK OK
HTTP: Open
www.smh.com.au OK OK OK OK OK OK OK OK OK

Please ensure UE camps on L7 cell before making test call.

7/25/2016 Work instruction For internal use Nokia 2016

53 / 55
11 References
11.1 4G LTE bands

4G LTE bands
B1 (2100)
B2 (1900)
B3 (1800)
B5 (850)
B7 (2600)
B8 (900)
B28 (700)
B40 (2300)

11.2 SFP modules used in L7/L18/L23/L26 eNB

SFP modules for 3 Gbps RP3-01 link speed

SFP modules for RP3-01 6 Gbps link speed

7/25/2016 Work instruction For internal use Nokia 2016

54 / 55
11.3 FSMF LMP connector pin map

7/25/2016 Work instruction For internal use Nokia 2016

55 / 55