Hydraulic Principles: Continuing Education Professional Development Course
Hydraulic Principles: Continuing Education Professional Development Course
Hydraulic Principles: Continuing Education Professional Development Course
CONTINUING EDUCATION
PROFESSIONAL DEVELOPMENT COURSE
2
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Printing and Saving Instructions
The best thing to do is to download this pdf document to your computer
desktop and open it with Adobe Acrobat reader.
Adobe Acrobat reader is a free computer software program and you can
find it at Adobe Acrobats website.
You can complete the course by viewing the course materials on your
computer or you can print it out. We give you permission to print this
document.
This course booklet does not have the assignment. Please visit our
website and download the assignment also.
Link to Assignment
http://www.tlch2o.com/PDF/HYDRAULICS%20ASSIGNMENT.pdf
State Approval Listing Link, check to see if your State accepts or has pre-
approved this course. Not all States are listed. Not all courses are listed.
If the course is not accepted for CEU credit, we will give you the course free
if you ask your State to accept it for credit and we receive the approval letter.
Professional Engineers; Most states will accept our courses for credit but
we do not officially list the States or Agencies.
3
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
4
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Library of Congress Card Number 6558651
ISBN 978-0-9799559-8-3
Copyright Notice
2005 Technical Learning College (TLC) No part of this work may be reproduced or distributed
in any form or by any means without TLCs prior written approval. Permission has been sought
for all images and text where we believe copyright exists and where the copyright holder is
traceable and contactable. All material that is not credited or acknowledged is the copyright of
Technical Learning College. This information is intended for educational purposes only. Most
unaccredited photographs have been taken by TLC instructors or TLC students. We will be
pleased to hear from any copyright holder and will make good on your work if any unintentional
copyright infringements were made as soon as these issues are brought to the editor's attention.
Every possible effort is made to ensure that all information provided in this course is accurate. All
written, graphic, photographic or other material is provided for information only. Therefore,
Technical Learning College accepts no
responsibility or liability whatsoever for the
application or misuse of any information
included herein. Requests for
Contributing Editors
Joseph Camerata has a BS in Management with honors (magna cum laude). He retired as a
Chemist in 2006 having worked in the field of chemical, environmental, and industrial hygiene
sampling and analysis for 40 years. He has been a professional presenter at an EPA analytical
conference at the Biosphere in Arizona and a presenter at an AWWA conference in Mesa,
Arizona. He also taught safety classes at the Honeywell and City of Phoenix, and is a
motivational/inspirational speaker nationally and internationally.
5
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
6
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Technical Learning Colleges Scope and Function
Technical Learning College (TLC) offers affordable continuing education for todays working
professionals who need to maintain licenses or certifications. TLC holds approximately eighty
different governmental approvals for granting of continuing education credit.
TLCs delivery method of continuing education can include traditional types of classroom
lectures and distance-based courses or independent study. Most of TLCs distance based or
independent study courses are offered in a print based format and you are welcome to
examine this material on your computer with no obligation. Our courses are designed to be
flexible and for you do finish the material on your leisure. Students can also receive course
materials through the mail. The CEU course or e-manual will contain all your lessons, activities
and assignments.
Most CEU courses allow students to submit lessons using e-mail or fax; however some
courses require students to submit lessons by postal mail. (See the course description for
more information.) Students have direct contact with their instructorprimarily by e-mail.
TLCs CEU courses may use such technologies as the World Wide Web, e-mail, CD-ROMs,
videotapes and hard copies. (See the course description.) Make sure you have access to the
necessary equipment before enrolling, i.e., printer, Microsoft Word and/or Adobe Acrobat
Reader. Some courses may require proctored exams depending upon your state
requirements.
Flexible Learning
At TLC, there are no scheduled online sessions you need contend with, nor are you required
to participate in learning teams or groups designed for the "typical" younger campus based
student. You will work at your own pace, completing assignments in time frames that work
best for you. TLC's method of flexible individualized instruction is designed to provide each
student the guidance and support needed for successful course completion.
We will beat any other training competitors price for the same CEU material or classroom
training. Student satisfaction is guaranteed.
Course Structure
TLC's online courses combine the best of online delivery and traditional university textbooks.
Online you will find the course syllabus, course content, assignments, and online open book
exams. This student friendly course design allows you the most flexibility in choosing when
and where you will study.
Classroom of One
TLC Online offers you the best of both worlds. You learn on your own terms, on your own
time, but you are never on your own. Once enrolled, you will be assigned a personal Student
Service Representative who works with you on an individualized basis throughout your
program of study. Course specific faculty members are assigned at the beginning of each
course providing the academic support you need to successfully complete each course.
Satisfaction Guaranteed
Our Iron-Clad, Risk-Free Guarantee ensures you will be another satisfied TLC student. We
have many years of experience dealing with thousands of students. We assure you, our
7
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
customer satisfaction is second to none. This is one reason we have taught more than
10,000 students.
Our administrative staff is trained to provide the best customer service in town. Part of that
training is knowing how to solve most problems on the spot with an exchange or refund.
For security purposes, please fax or e-mail a copy of your drivers license and always
call us to confirm weve received your assignment and to confirm your identity.
Thank you
8
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
CEU Course Description
Hydraulic Principles CEU Training Course
This short CEU course will review of hydraulic fundamentals and principles--from taking this CEU
course, the student will develop an understanding of the engineering science pertaining to liquid
pressure and flow. This course will cover the basics of hydraulic fundamentals commonly related
to the study of the mechanical properties of water. This course will also examine hydrostatics or
fluid mechanics as well as the history and development of pumps, hydraulics and the science of
fluids. This training course will present several familiar topics in hydraulics and hydrostatics
which often appear in most educational expositions of introductory science, and which are also of
historical interest that can enliven a students educational experience. You will not need any other
materials for this course.
Water Distribution, Well Drillers, Pump Installers, Water Treatment Operators, Wastewater
Treatment Operators, Wastewater Collection Operators, Industrial Wastewater Operators,
Customer Service Professionals and General Backflow Assembly Testers--the target
audience for this course is the person interested in working in a water or wastewater treatment or
distribution/collection facility and/or wishing to maintain CEUs for certification license or to learn
how to do the job safely and effectively, and/or to meet education needs for promotion.
Prerequisites: None
When a student registers for a distance or correspondence course, he/she is assigned a start
date and an end date. It is the student's responsibility to note dates for assignments and keep up
with the course work. If a student falls behind, he/she must contact TLC and request an end date
extension in order to complete the course. It is the prerogative of TLC to decide whether to grant
the request. All students will be tracked by a unique number will be assigned to the student.
9
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Security and Integrity
All students are required to do their own work. All lesson sheets and final exams are not returned
to the student to discourage sharing of answers. Any fraud or deceit and the student will forfeit
all fees and the appropriate agency will be notified.
Grading Criteria
TLC will offer the student either pass/fail or a standard letter grading assignment. If TLC is not
notified, you will only receive a pass/fail notice.
Required Texts
The Hydraulic Principles CEU training course will not require any other materials. This course
comes complete. No other materials are needed.
ADA Compliance
TLC will make reasonable accommodations for persons with documented disabilities. Students
should notify TLC and their instructors of any special needs. Course content may vary from this
outline to meet the needs of this particular group. Please check with your State for special
instructions.
You will have 90 days from receipt of this manual to complete it in order to receive your Continuing
Education Units (CEUs) or Professional Development Hours (PDHs). A score of 70% or better
is necessary to pass this course. If you should need any assistance, please email all concerns
and the final test to: info@tlch2o.com.
Educational Mission
The educational mission of TLC is:
To provide TLC students with comprehensive and ongoing training in the theory and skills needed
for the environmental education field,
To provide TLC students opportunities to apply and understand the theory and skills needed for
operator certification and environmental education,
To provide opportunities for TLC students to learn and practice environmental educational skills
with members of the community for the purpose of sharing diverse perspectives and experience,
To provide a forum in which students can exchange experiences and ideas related to
environmental education,
To provide a forum for the collection and dissemination of current information related to
environmental education, and to maintain an environment that nurtures academic and personal
growth.
10
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Important Information about this Manual
This manual has been prepared to educate operators in the general education of hydraulic
principles, including basic mechanical and mathematical training and different hydraulic
applications. For most students, the study of hydraulics is quite large, requiring a major effort to
bring it under control and understanding.
This manual should not be used as a guidance document for employees who are involved with
cross-connection control. It is not designed to meet the requirements of the United States
Environmental Protection Agency (EPA), the Department of Labor-Occupational Safety and
Health Administration (OSHA), or your state environmental or health agency. Technical Learning
College or Technical Learning Consultants, Inc. makes no warranty, guarantee or representation
as to the absolute correctness or appropriateness of the information in this manual and assumes
no responsibility in connection with the implementation of this information.
It cannot be assumed that this manual contains all measures and concepts required for specific
conditions or circumstances. This document should be used for educational purposes and is not
considered a legal document. Individuals who are responsible for hydraulic equipment, cross-
connection control, backflow prevention or water distribution should obtain and comply with the
most recent federal, state, and local regulations relevant to these sites and are urged to consult
with OSHA, the EPA and other appropriate federal, state and local agencies.
In this course, you will learn the various and interesting physic laws and the long exciting history
related to hydraulic power as well as hydraulic terms and mathematics commonly used throughout
the water related industry. This is a universal course that can be utilized by all classifications and
positions.
The reason this course is universal is because we examine how water works. Here are some
examples: Industrial Inspector that needs to know how to figure a water flow. A Plumbing or
Customer Inspector who needs to figure flow restriction in a water line. This course will cover
several unique and interesting water related facts that most of us have forgotten or havent
recognized.
11
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
12
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
TABLE OF CONTENTS
Archimedes......................... 17
Hydraulic Principles............. 23
Atmospheric Pressure......... 24
Pressure.............................. 26
Geometric Arguments.......... 28
Vacuum................................ 29
Development....................... 33
Hydraulic Level.................... 36
Hydrostatic Paradox............. 41
Backflow............................... 51
Events................................... 52
Pump Section....................... 71
Pump Definitions.................. 75
Pump.................................... 77
Types of Pumps.................... 79
Basic Pump.......................... 83
Progressive Cavity................ 93
Screw Pump......................... 97
Submersible......................... 99
Vertical Turbine.................... 101
Centrifugal............................ 107
NPSH................................... 111
Pump Curves....................... 115
Motors.................................. 133
Couplings............................. 139
Mechanical Seals................. 143
Troubleshooting................... 149
Electrical Glossary................ 153
Well Selection....................... 159
Pump Surging....................... 161
Glossary............................... 183
Appendixes.......................... 225
Math Conversions. 247
Math Exercise...................... 255
References 285
13
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
14
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Common Hydraulic Terms
Head
The height of a column or body of fluid above a given point expressed in linear units.
Head is often used to indicate gauge pressure. Pressure is equal to the height times the
density of the liquid.
Head, Friction
The head required to overcome the friction at the interior surface of a conductor and
between fluid particles in motion. It varies with flow, size, type, and conditions of
conductors and fittings, and the fluid characteristics.
Head, static
The height of a column or body of fluid above a given point.
Hydraulics
Engineering science pertaining to liquid pressure and flow.
Hydrokinetics
Engineering science pertaining to the energy of liquid flow and pressure.
Pascal's Law
A pressure applied to a confined fluid at rest is transmitted with equal intensity throughout
the fluid.
Pressure
The application of continuous force by one body upon another that it is touching;
compression. Force per unit area, usually expressed in pounds per square inch (Pascal
or bar).
Pressure, Absolute
The pressure above zone absolute, i.e. the sum of atmospheric and gauge pressure. In
vacuum related work it is usually expressed in millimeters of mercury. (mmHg).
Pressure, Atmospheric
Pressure exported by the atmosphere at any specific location. (Sea level pressure is
approximately 14.7 pounds per square inch absolute, 1 bar = 14.5psi.)
Pressure, Gauge
Pressure differential above or below ambient atmospheric pressure.
Pressure, Static
The pressure in a fluid at rest.
15
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
16
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Archimedes The King of Hydraulics
17
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
This pump is at least 2,000 years old.
The Archimedes Screw (also called an Archimedes Snail) was used for irrigation and powered by
horses, people, mules, etc. This pump is even used today, although rarely! The helix revolves
inside a tube (only the bottom of the tube is shown) and the water rises accordingly. Whether or
not it was actually invented by Archimedes is certainly debatable, though his overall brilliance is
not.
18
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Archimedes
Born About 287 BC in Syracuse, Sicily. At the time, Syracuse was an independent
Greek city-state with a 500-year history.
Died 212 or 211 BC in Syracuse when it was being sacked by a Roman army. He
was killed by a Roman soldier who did not know who he was.
Family His father was an astronomer named Phidias and he was probably related to
Hieron II, the king of Syracuse. It is not known whether he was married nor
had any children.
Inventions Many war machines used in the defense of Syracuse, compound pulley
systems, planetarium, water screw (possibly), water organ (possibly), burning
mirrors (very unlikely).
Archimedes was a great mathematician of ancient times. His greatest contributions were in
geometry. He also spent some time in Egypt, where he invented the machine now called
Archimedes' screw, which was a mechanical water pump. Among his most famous works is
Measurement of the Circle, where he determined the exact value of pi between the two fractions,
3 10/71 and 3 1/7. He got this information by inscribing and circumscribing a circle with a 96-sided
regular polygon.
Archimedes made many contributions to geometry in his work in the areas of plane figures and in
the areas of area and volumes of curved surfaces. His methods started the idea for calculus which
was "invented" 2,000 years later by Sir Isaac Newton and Gottfried Wilhelm von Leibniz.
Archimedes proved that the volume of an inscribed sphere is two-thirds the volume of a
circumscribed cylinder. He requested that this formula/diagram be inscribed on his tomb.
19
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
His works (that survived) include:
Measurement of a Circle
On the Sphere and Cylinder
On Spirals
The Sand Reckoner
The Romans highest numeral was a myriad (10,000). Archimedes was not content to use that as
the biggest number, so he decided to conduct an experiment using large numbers. The question:
How many grains of sand there are in the universe? He made up a system to measure the sand.
While solving this problem, Archimedes discovered something called powers. The answer to
Archimedes' question was one with 62 zeros after it (1 x 1062).
1 = 0 power=20
2 = 1st power=21
2 x 2 x 2 x 2= 4th power=24
There are short ways to write exponents. For example, a short way to
write 81 is 34.This is read as three to the fourth power.
On Plane Equilibriums
On Floating Bodies
This problem was after Archimedes had solved the problem of King Hieros gold crown. He
experimented with liquids. He discovered density and specific gravity.
20
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Daniel Bernoulli was born in Groningen, in the Netherlands, into a family of distinguished
mathematicians. The Bernoulli family came originally from Antwerp, at that time in the Spanish
Netherlands, but emigrated to escape the Spanish persecution of the Huguenots. After a brief
period in Frankfurt the family moved to Basel, in Switzerland.
Daniel was the son of Johann Bernoulli (one of the "early developers" of calculus), nephew of
Jakob Bernoulli (who "was the first to discover the theory of probability"), and older brother of
Johann II. Daniel Bernoulli was described by W. W. Rouse Ball as "by far the ablest of the younger
Bernoullis". He is said to have had a bad relationship with his father, Johann. Upon both of them
entering and tying for first place in a scientific contest at the University of Paris, Johann, unable
to bear the "shame" of being compared as Daniel's equal, banned Daniel from his house. Johann
Bernoulli also plagiarized some key ideas from Daniel's book Hydrodynamica in his own book
Hydraulica which he backdated to before Hydrodynamica. Despite Daniel's attempts at
reconciliation, his father carried the grudge until his death.
When Daniel was seven, his younger brother Johann II Bernoulli was born. Around schooling age,
his father, Johann Bernoulli, encouraged him to study business, there being poor rewards
awaiting a mathematician. However, Daniel refused, because he wanted to study mathematics.
He later gave in to his father's wish and studied business.
21
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Blaise Pascal 19 June 1623 19 August 1662) was a French mathematician, physicist, inventor,
writer and Christian philosopher. He was a child prodigy who was educated by his father, a tax
collector in Rouen. Pascal's earliest work was in the natural and applied sciences where he made
important contributions to the study of fluids, and clarified the concepts of pressure and vacuum
by generalizing the work of Evangelista Torricelli. Pascal also wrote in defense of the scientific
method.
In 1642, while still a teenager, he started some pioneering work on calculating machines. After
three years of effort and fifty prototypes, he invented the mechanical calculator. He built 20 of
these machines (called Pascals calculator and later pascaline) in the following ten years. Pascal
was an important mathematician, helping create two major new areas of research: he wrote a
significant treatise on the subject of projective geometry at the age of 16, and later corresponded
with Pierre de Fermat on probability theory, strongly influencing the development of modern
economics and social science. Following Galileo and Torricelli, in 1646 he refuted Aristotle's
followers who insisted that nature abhors a vacuum. Pascal's results caused many disputes
before being accepted.
In 1646, he and his sister Jacqueline identified with the religious movement within Catholicism
known by its detractors as Jansenism. His father died in 1651. Following a mystical experience
in late 1654, he had his "second conversion", abandoned his scientific work, and devoted himself
to philosophy and theology. His two most famous works date from this period: the Lettres
provinciales and the Penses, the former set in the conflict between Jansenists and Jesuits. In
this year, he also wrote an important treatise on the arithmetical triangle. Between 1658 and 1659
he wrote on the cycloid and its use in calculating the volume of solids. Pascal had poor health
especially after his 18th year and his death came just two months after his 39th birthday.
22
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Hydraulic Principles Section Question 100
Definition: Hydraulics is a branch of engineering concerned mainly with moving liquids. The
term is applied commonly to the study of the mechanical properties of water, other liquids, and
even gases when the effects of compressibility are small. Hydraulics can be divided into two
areas, hydrostatics and hydrokinetics.
Hydrostatics
Hydrostatics is about the pressures exerted by a fluid at
rest. Any fluid is meant, not just water. Research and
careful study on water yields many useful results of its own,
however, such as forces on dams, buoyancy and hydraulic actuation, and is well worth studying
for such practical reasons.
There are few better illustrations of the use of the integral calculus, as well as the principles of
ordinary statics, available to the student. A great deal can be done with only elementary
mathematics. Properly adapted, the material can be used from the earliest introduction of school
science, giving an excellent example of a quantitative science with many possibilities for hands-
on experiences.
The definition of a fluid deserves careful consideration. Although time is not a factor in
hydrostatics, it enters in the approach to hydrostatic equilibrium. It is usually stated that a fluid is
a substance that cannot resist a shearing stress, so that pressures are normal to confining
surfaces. Geology has now shown us clearly that there are substances which can resist shearing
forces over short time intervals, and appear to be typical solids, but which flow like liquids over
long time intervals. Such materials include wax and pitch, ice, and even rock.
23
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A ball of pitch, which can be shattered by a hammer, will spread out and flow in months. Ice, a
typical solid, will flow in a period of years, as shown in glaciers, and rock will flow over hundreds
of years, as in convection in the mantle of the earth.
Shear earthquake waves, with periods of seconds, propagate deep in the earth, though the rock
there can flow like a liquid when considered over centuries. The rate of shearing may not be
strictly proportional to the stress, but exists even with low stress.
Viscosity may be the physical property that varies over the largest numerical range, competing
with electrical resistivity. There are several familiar topics in hydrostatics which often appears in
expositions of introductory science, and which are also of historical interest and can enliven their
presentation. Lets start our study with the principles of our atmosphere.
Atmospheric Pressure
The atmosphere is the entire mass of air that surrounds the earth. While it extends upward for
about 500 miles, the section of primary interest is the portion that rests on the earths surface and
extends upward for about 7 1/2 miles. This layer is called the troposphere.
If a column of air 1-inch square extending all the way to the "top" of the atmosphere could be
weighed, this column of air would weigh approximately 14.7 pounds at sea level. Thus,
atmospheric pressure at sea level is approximately 14.7 psi.
As one ascends, the atmospheric pressure decreases by approximately 1.0 psi for every 2,343
feet. However, below sea level, in excavations and depressions, atmospheric pressure increases.
Pressures under water differ from those under air only because the weight of the water must be
added to the pressure of the air.
Atmospheric pressure can be measured by any of several methods. The common laboratory
method uses the mercury column barometer. The height of the mercury column serves as an
indicator of atmospheric pressure. At sea level and at a temperature of 0 Celsius (C), the height
of the mercury column is approximately 30 inches, or 76 centimeters. This represents a pressure
of approximately 14.7 psi. The 30-inch column is used as a reference standard.
Another device used to measure atmospheric pressure is the aneroid barometer. The aneroid
barometer uses the change in shape of an evacuated metal cell to measure variations in
atmospheric pressure. The thin metal of the aneroid cell moves in or out with the variation of
pressure on its external surface. This movement is transmitted through a system of levers to a
pointer, which indicates the pressure.
The atmospheric pressure does not vary uniformly with altitude. It changes very rapidly.
Atmospheric pressure is defined as the force per unit area exerted against a surface by the weight
of the air above that surface. In the diagram on the following page, the pressure at point "X"
increases as the weight of the air above it increases. The same can be said about decreasing
pressure, where the pressure at point "X" decreases if the weight of the air above it also
decreases.
24
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Barometric Loop
The barometric loop consists of a continuous section of supply
piping that abruptly rises to a height of approximately 35 feet
and then returns back down to the originating level. It is a loop
in the piping system that effectively protects against
backsiphonage. It may not be used to protect against back-
pressure.
25
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pressure
By a fluid, we have a material in mind like water or air, two very common and important fluids.
Water is incompressible, while air is very compressible, but both are fluids. Water has a definite
volume; air does not. Water and air have low viscosity; that is, layers of them slide very easily on
one another, and they quickly assume their permanent shapes when disturbed by rapid flows.
Other fluids, such as molasses, may have high viscosity and take a long time to come to
equilibrium, but they are no less fluids. The coefficient of viscosity is the ratio of the shearing force
to the velocity gradient. Hydrostatics deals with permanent, time-independent states of fluids, so
viscosity does not appear, except as discussed in the Introduction.
A fluid, therefore, is a substance that cannot exert any permanent forces tangential to a boundary.
Any force that it exerts on a boundary must be normal to the boundary. Such a force is proportional
to the area on which it is exerted, and is called a pressure. We can imagine any surface in a fluid
as dividing the fluid into parts pressing on each other, as if it were a thin material membrane, and
so think of the pressure at any point in the fluid, not just at the boundaries. In order for any small
element of the fluid to be in equilibrium, the pressure must be the same in all directions (or the
element would move in the direction of least pressure), and if no other forces are acting on the
body of the fluid, the pressure must be the same at all neighboring points.
Therefore, in this case the pressure will be the same throughout the fluid, and the same in any
direction at a point (Pascal's Principle). Pressure is expressed in units of force per unit area such
as dyne/cm2, N/cm2 (pascal), pounds/in2 (psi) or pounds/ft2 (psf). The axiom that if a certain
volume of fluid were somehow made solid, the equilibrium of forces would not be disturbed is
useful in reasoning about forces in fluids.
26
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
On earth, fluids are also subject to the force of gravity, which acts vertically downward, and has
a magnitude = g per unit volume, where g is the acceleration of gravity, approximately 981
cm/s2 or 32.15 ft/s2, is the density, the mass per unit volume, expressed in g/cm3, kg/m3, or
slug/ft3, and is the specific weight, measured in lb/in3, or lb/ft3 (pcf). Gravitation is an example of
a body force that disturbs the equality of pressure in a fluid. The presence of the gravitational
body force causes the pressure to increase with depth, according to the equation dp = g dh, in
order to support the water above. We call this relation the barometric equation, for when this
equation is integrated, we find the variation of pressure with height or depth. If the fluid is
incompressible, the equation can be integrated at once, and the pressure as a function of depth
h is p = gh + p0.
27
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Free Surface Perpendicular to Gravity
When gravity acts, the liquid assumes a free surface perpendicular to gravity, which can be proved
by Thomson's method. A straight cylinder of unit cross-sectional area (assumed only for ease in
the arithmetic) can be used to find the increase of pressure with depth. Indeed, we see that p2 =
p1 + gh. The upper surface of the cylinder can be placed at the free surface if desired. The
pressure is now the same in any direction at a point, but is greater at points that lie deeper. From
this same figure, it is easy to prove Archimedes Principle that the buoyant force is equal to the
weight of the displaced fluid, and passes through the center of mass of this displaced fluid.
Geometric Arguments
Ingenious geometric arguments can be used to
substitute for easier, but less transparent arguments
using calculus. For example, the force acting on one
side of an inclined plane surface whose projection is
AB can be found as in the diagram on the previous
page. O is the point at which the prolonged projection
intersects the free surface.
Now start the pump. When it has sucked all the air out above the water, the pressure on the
surface of the water inside the pipe is zero, and the pressure at the level of the water on the
outside of the pipe is still the atmospheric pressure. Of course, there is the vapor pressure of the
water to worry about if you want to be precise, but we neglect this complication in making our
point.
We require a column of water 33.9 ft high inside the pipe, with a vacuum above it, to balance the
atmospheric pressure. Now do the same thing with liquid mercury, whose density at 0 C is
13.5951 times that of water. The height of the column is 2.494 ft, 29.92 in, or 760.0 mm.
28
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Standard Atmospheric Pressure
This definition of the standard atmospheric pressure was established by Regnault in the mid-19th
century. In Britain, 30 in. Hg (inches of mercury) had been used previously. As a practical matter,
it is convenient to measure pressure differences by measuring the height of liquid columns, a
practice known as manometry. The barometer is a familiar example of this, and atmospheric
pressures are traditionally given in terms of the length of a mercury column. To make a barometer,
the barometric tube, closed at one end, is filled with mercury and then inverted and placed in a
mercury reservoir. Corrections must be made for temperature, because the density of mercury
depends on the temperature, and the brass scale expands for capillarity if the tube is less than
about 1 cm in diameter, and even slightly for altitude, since the value of g changes with altitude.
The vapor pressure of mercury is only 0.001201 mmHg at 20C, so a correction from this source
is negligible. For the usual case of a mercury column ( = 0.000181792 per C) and a brass scale
(&alpha = 0.0000184 per C) the temperature correction is -2.74 mm at 760 mm and 20C. Before
reading the barometer scale, the mercury reservoir is raised or lowered until the surface of the
mercury just touches a reference point, which is mirrored in the surface so it is easy to determine
the proper position.
Vacuum
The term vacuum indicates that the absolute pressure is less than the atmospheric pressure and
that the gauge pressure is negative. A complete or total vacuum would mean a pressure of 0
psia or 14.7 psig. Since it is impossible to produce a total vacuum, the term vacuum, as used in
this document, will mean all degrees of partial vacuum. In a partial vacuum, the pressure would
range from slightly less than 14.7 psia (0 psig) to slightly greater than 0 psia (-14.7 psig).
Backsiphonage results from atmospheric pressure exerted on a liquid, forcing it toward a supply
system that is under a vacuum.
29
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Water Pressure
The weight of a cubic foot of water is 62.4 pounds per square foot. The base can be subdivided
into 144-square inches with each subdivision being subjected to a pressure of 0.433 psig.
Suppose you placed another cubic foot of water on top of the first cubic foot. The pressure on
the top surface of the first cube which was originally atmospheric, or 0 psig, would now be 0.4333
psig as a result of the additional cubic foot of water. The pressure of the base of the first cubic
foot would be increased by the same amount of 0.866 psig or two times the original pressure.
Pressures are very frequently stated in terms of the height of a fluid. If it is the same fluid whose
pressure is being given, it is usually called "head," and the factor connecting the head and the
pressure is the weight density g. In the English engineer's system, weight density is in pounds
per cubic inch or cubic foot. A head of 10 ft is equivalent to a pressure of 624 psf, or 4.33 psi. It
can also be considered an energy availability of ft-lb per lb. Water with a pressure head of 10 ft
can furnish the same energy as an equal amount of water raised by 10 ft. Water flowing in a pipe
is subject to head loss because of friction.
Take a jar and a basin of water. Fill the jar with water and invert it under the water in the basin.
Now raise the jar as far as you can without allowing its mouth to come above the water surface.
It is always a little surprising to see that the jar does not empty itself, but the water remains with
no visible means of support. By blowing through a straw, one can put air into the jar, and as much
water leaves as air enters. In fact, this is a famous method of collecting insoluble gases in the
chemical laboratory, or for supplying hummingbird feeders. It is
good to remind oneself of exactly the balance of forces involved.
In the diagram, the two water levels are the same, so there will
be no flow. When a siphon goes below the free water levels, it
is called an inverted siphon. If the levels in the two basins are
not equal, fluid flows from the basin with the higher level into
the one with the lower level, until the levels are equal.
A siphon can be made by filling the tube, closing the ends, and
then putting the ends under the surface on both sides.
Alternatively, the tube can be placed in one fluid and filled by sucking on it. When it is full, the
other end is put in place. The analysis of the siphon is easy, and should be obvious. The
pressure rises or falls as described by the barometric equation through the siphon tube.
There is obviously a maximum height for the siphon which is the same as the limit of the suction
pump, about 34 feet. Inverted siphons are sometimes used in pipelines to cross valleys.
Differences in elevation are usually too great to use regular siphons to cross hills, so the fluids
must be pressurized by pumps so the pressure does not fall to zero at the crests.
30
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Liquids at Rest
In studying fluids at rest, we are concerned with the transmission of force and the factors which
affect the forces in liquids. Additionally, pressure in and on liquids and factors affecting pressure
are of great importance.
The terms force and pressure are used extensively in the study of fluid power. It is essential that
we distinguish between the terms.
Force means a total push or pull. It is the push or pull exerted against the total area of a particular
surface and is expressed in pounds or grams. Pressure means the amount of push or pull (force)
applied to each unit area of the surface and is expressed in pounds per square inch (lb/in2) or
grams per square centimeter (gm/cm2). Pressure maybe exerted in one direction, in several
directions, or in all directions.
31
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
32
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Development of Hydraulics Question 173
Although the modern development of hydraulics is comparatively recent, the ancients were
familiar with many hydraulic principles and their applications. The Egyptians and the ancient
people of Persia, India, and China conveyed water along channels for irrigation and domestic
purposes, using dams and sluice gates to control the flow. The ancient Cretans had an elaborate
plumbing system. Archimedes studied the laws of floating and submerged bodies. The Romans
constructed aqueducts to carry water to their cities.
After the breakup of the ancient world, there were few new developments for many centuries.
Then, over a comparatively short period, beginning near the end of the seventeenth century,
Italian physicist, Evangelista Torricelle, French physicist, Edme Mariotte, and later, Daniel
Bernoulli conducted experiments to study the elements of force in the discharge of water through
small openings in the sides of tanks and through short pipes. During the same period, Blaise
Pascal, a French scientist, discovered the fundamental law for the science of hydraulics. Pascals
law states that increase in pressure on the surface of a confined fluid is transmitted undiminished
throughout the confining vessel or system.
For Pascals law to be made effective for practical applications, it was necessary to have a piston
that "fit exactly." It was not until the latter part of the eighteenth century that methods were found
to make these snugly fitted parts required in hydraulic systems.
This was accomplished by the invention of machines that were used to cut and shape the
necessary closely fitted parts and, particularly, by the development of gaskets and packings.
Since that time, components such as valves, pumps, actuating cylinders, and motors have been
developed and refined to make hydraulics one of the leading methods of transmitting power.
Liquids are almost incompressible. For example, if a pressure of 100 pounds per square inch
(psi) is applied to a given volume of water that is at atmospheric pressure, the volume will
decrease by only 0.03 percent. It would take a force of approximately 32 tons to reduce its volume
by 10 percent; however, when this force is removed, the water immediately returns to its original
volume. Other liquids behave in about the same manner as water.
Another characteristic of a liquid is the tendency to keep its free surface level. If the surface is not
level, liquids will flow in the direction which will tend to make the surface level.
Evangelista Torricelli
Evangelista Torricelli (1608-1647), Galileo's student and secretary and a member of the
Florentine Academy of Experiments, invented the mercury barometer in 1643, and brought the
weight of the atmosphere to light. The mercury column was held up by the pressure of the
atmosphere, not by horror vacui as Aristotle had supposed. Torricelli's early death was a blow to
science, but his ideas were furthered by Blaise Pascal (1623-1662).
Pascal had a barometer carried up the 1465 m high Puy de Dme, an extinct volcano in the
Auvergne just west of his home of Clermont-Ferrand in 1648 by Prier, his brother-in-law. Pascal's
experimentum crucis is one of the triumphs of early modern science. The Puy de Dme is not the
highest peak in the Massif Central--the Puy de Sancy, at 1866 m is, but it was the closest.
Clermont is now the center of the French pneumatics industry.
33
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Burgomeister of Magdeburg
The remarkable Otto von Guericke (1602-1686), Burgomeister of Magdeburg, Saxony, took up
the cause, making the first vacuum pump, which he used in vivid
demonstrations of the pressure of the atmosphere to the Imperial
Diet at Regensburg in 1654. Famously, he evacuated a sphere
consisting of two well-fitting hemispheres about a foot in diameter,
and showed that 16 horses, 8 on each side, could not pull them
apart. An original vacuum pump and hemispheres from 1663 are
shown at the right (photo edited from the Deutsches Museum; see
on right). He also showed that air had weight, and how much force
it did require to separate evacuated hemispheres. Then, in
England, Robert Hooke (1635-1703) made a vacuum pump for
Robert Boyle (1627-1691). Christian Huygens (1629-1695)
became interested in a visit to London in 1661 and had a vacuum pump built for him. By this
time, Torricelli's doctrine had triumphed over the Church's support for horror vacui. This was
one of the first victories for rational physics over the illusions of experience, and is well worth
consideration.
Pascal demonstrated that the siphon worked by atmospheric pressure, not by horror vacui. The
two beakers of mercury are connected by a three-way tube as shown, with the upper branch open
to the atmosphere. As the large container is filled with water, pressure on the free surfaces of the
mercury in the beakers pushes mercury into the tubes. When the state shown is reached, the
beakers are connected by a mercury column, and the siphon starts, emptying the upper beaker
and filling the lower. The mercury has been open to the atmosphere all this time, so if there were
any horror vacui, it could have flowed in at will to soothe itself.
Torr
The mm of mercury is sometimes called a torr after Torricelli, and Pascal also has been honored
by a unit of pressure, a newton per square meter or 10 dyne/cm2. A cubic centimeter of air weighs
1.293 mg under standard conditions, and a cubic meter 1.293 kg, so air is by no means even
approximately weightless, though it seems so. The weight of a sphere of air as small as 10 cm
in diameter is 0.68 g, easily measurable with a chemical balance. The pressure of the atmosphere
is also considerable, like being 34 ft under water, but we do not notice it. A bar is 106 dyne/cm2,
very close to a standard atmosphere, which is 1.01325 bar. In meteorology, the millibar, mb, is
used. 1 mb = 1.333 mmHg = 100 Pa = 1000 dyne/cm2.
A kilogram-force per square centimeter is 981,000 dyne/cm2, also close to one atmosphere. In
Europe, it has been considered approximately 1 atm, as in tire pressures and other engineering
applications.
As we have seen, in English units the atmosphere is about 14.7 psi, and this figure can be used
to find other approximate equivalents. For example, 1 psi = 51.7 mmHg. In Britain, tons per square
inch has been used for large pressures. The ton in this case is 2240 lb, not the American short
ton. 1 tsi = 2240 psi, 1 tsf = 15.5 psi (about an atmosphere!).The fluid in question here is air, which
is by no means incompressible. As we rise in the atmosphere and the pressure decreases, the
air also expands.
34
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
To see what happens in this case, we can make use of the ideal gas equation of state, p = RT/M,
and assume that the temperature T is constant. Then the change of pressure in a change of
altitude dh is dp = -g dh = - (pM/RT) gdh, or dp/p = - (Mg/RT) dh.
This is a little harder to integrate than before, but the result is ln p = -Mgh/RT + C, or ln (p/p0) = -
Mgh/RT, or finally p = p0exp (-Mgh/RT).
Meteorology
The atmospheric pressure is of great importance in meteorology, since it determines the winds,
which generally move at right angles to the direction of the most rapid change of pressure, that
is, along the isobars, which are contours of constant pressure. Certain typical weather patterns
are associated with relatively high and relatively low pressures, and how they vary with time. The
barometric pressure may be given in popular weather forecasts, though few people know what to
do with it.
If you live at a high altitude, your local weather reporter may report the pressure to be, say, 29.2
inches, but if you have a real barometer, you may well find that it is closer to 25 inches. At an
elevation of 1500 m (near Denver, or the top of the Puy de Dme), the atmospheric pressure is
about 635 mm, and water boils at 95 C.
The barometric pressures quoted in the news are reduced to sea level by standard formulas
that amount to assuming that there is a column of air from your feet to sea level with a certain
temperature distribution, and adding the weight of this column to the actual barometric pressure.
This is only an arbitrary 'fix' and leads to some strange conclusions, such as the permanent
winter highs above high plateaus that are really imaginary.
35
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The Hydraulic Lever
A cylinder and piston is a chamber of variable volume, a mechanism for transforming pressure to
force.
Then the pressure is the same, p, in both cylinders. If the fluid is incompressible, then dV + dV' =
0, so that dW = p dV + p dV' = F dx + F' dx' = 0. This says the work done on one piston is equal
to the work done by the other piston: the conservation of energy. The ratio of the forces on the
pistons is F' / F = A' / A, the same as the ratio of the areas, and the ratios of the displacements
dx' / dx = F / F' = A / A' is in the inverse ratio of the areas. This mechanism is the hydrostatic
analogue of the lever, and is the basis of hydraulic activation.
This was the crucial problem that Bramah solved by his leather seal that was held against the
cylinder and the piston by the hydraulic pressure itself. In the presence of gravity, p' = p + gh,
where h is the difference in elevation of the two cylinders. Now, p' dV' = -dV (p + gh) =-p dV - (
dV) gh, or the net work done in the process is p' dV' + p dV = -dM gh, where dM is the mass of
fluid displaced from the lower cylinder to the upper cylinder. Again, energy is conserved if we take
into account the potential energy of the fluid. Pumps are seen to fall within the province of
hydrostatics if their operation is quasi-static, which means that dynamic or inertia forces are
negligible.
Pumps
Pumps are used to move or raise fluids. They are not only very useful, but are excellent examples
of hydrostatics. Pumps are of two general types, hydrostatic or positive displacement pumps, and
pumps depending on dynamic forces, such as centrifugal pumps. Here we will only consider
positive displacement pumps, which can be understood purely by hydrostatic considerations.
They have a piston (or equivalent) moving in a closely-fitting cylinder and forces are exerted on
the fluid by motion of the piston. We have already seen an important example of this in the
hydraulic lever or hydraulic press, which we have called quasi-static.
36
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The simplest pump is the syringe, filled by withdrawing the piston and emptied by pressing it back
in, as its port is immersed in the fluid or removed from it. More complicated pumps have valves
allowing them to work repetitively. These are usually check valves that open to allow passage in
one direction, and close automatically to prevent reverse flow. There are many kinds of valves,
and they are usually the most trouble-prone and complicated part of a pump. The force pump has
two check valves in the cylinder, one for supply and the other for delivery. The supply valve opens
when the cylinder volume increases, the delivery valve when the cylinder volume decreases.
The lift pump has a supply valve and a valve in the piston that allows the liquid to pass around it
when the volume of the cylinder is reduced. The delivery in this case is from the upper part of the
cylinder which the piston does not enter. Diaphragm pumps are force pumps in which the
oscillating diaphragm takes the place of the piston. The diaphragm may be moved mechanically,
or by the pressure of the fluid on one side of the diaphragm.
Some positive displacement pumps are shown below. The force and lift pumps are typically used
for water. The force pump has two valves in the cylinder, while the lift pump has a one valve in
the cylinder and one in the piston. The maximum lift, or "suction," is determined by the
atmospheric pressure, and either cylinder must be within this height of the free surface. The force
pump, however, can give an arbitrarily large pressure to the discharged fluid, as in the case of a
diesel engine injector. A nozzle can be used to convert the pressure to velocity, to produce a jet,
as for firefighting. Fire fighting force pumps usually have two cylinders feeding one receiver
alternately. The air space in the receiver helps to make the water pressure uniform.
The three pumps on the right are typically used for air, but would be equally applicable to
liquids. The Roots blower has no valves, their place taken by the sliding contact between the
rotors and the housing. The Roots blower can either exhaust a receiver or provide air under
moderate pressure, in large volumes. The bellows is a very old device, requiring no accurate
machining. The single valve is in one or both sides of the expandable chamber. Another valve
can be placed at the nozzle if required. The valve can be a piece of soft leather held close to
holes in the chamber.
37
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Dudley Castle Engine
The first engine may have been erected
in Cornwall in 1710, but the Dudley
Castle engine of 1712 is much better
known and thoroughly documented.
The first pumps used in Cornwall were
called bucket pumps, which we
recognize as lift pumps, with the
pistons somewhat miscalled buckets.
They pumped on the up-stroke, when a
clack in the bottom of the pipe opened
and allowed water to enter beneath the
piston. At the same time, the piston
lifted the column of water above it,
which could be of any length. The
piston could only "suck" water 33 ft, or
28 ft more practically, of course, but
this occurred at the bottom of the shaft,
so this was only a limit on the piston
stroke. On the down stroke, a clack in
the bucket opened, allowing it to sink through the water to the bottom, where it would be ready
to make another lift. More satisfactory were the plunger pumps, also placed at the bottom of the
shaft. A plunger displaced volume in a chamber, forcing the water in it through a check valve up
the shaft, when it descended. When it rose, water entered the pump chamber through a clack,
as in the bucket pump.
Only the top of the plunger had to be packed; it was not necessary that it fit the cylinder accurately.
In this case, the engine at the surface lifted the heavy pump rods on the up-stroke. When the
atmospheric engine piston returned, the heavy timber pump rods did the actual pumping, borne
down by their weight. A special application for pumps is to produce a vacuum by exhausting a
container, called the receiver.
Bell-jar Receiver
The bell-jar receiver, invented by Huygens, is shown; previously, a cumbersome globe was the
usual receiver. Tate's air pump is a 19th century pump that would be used for simple vacuum
demonstrations and for utility purposes in the lab. It has no valves on the low-pressure side, just
exhaust valves V, V', so it could probably reach about 1 mmHg. It is operated by pushing and
pulling the handle H. At the present day, motor-driven rotary-seal pumps sealed by running in oil
are used for the same purpose. At the right is Sprengel's pump, with the valves replaced by drops
of mercury.
38
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Small amounts of gas are trapped at the top of the fall tube as the mercury drops, and moves
slowly down the fall tube as mercury is steadily added, coming out at the bottom carrying the air
with it. The length of the fall tube must be greater than the barometric height, of course.
Theoretically, a vacuum of about 1 m can be obtained with a Sprengel pump, but it is very slow
and can only evacuate small volumes. Later, Langmuir's mercury diffusion pump, which was much
faster, replaced Sprengel pumps, and led to oil diffusion pumps that can reach very high vacua.
The column of water or hydrostatic engine is the inverse of the force pump,
used to turn a large head (pressure) of water into rotary motion. It looks like
a steam engine, with valves operated by valve gear, but of course is not a
heat engine and can be of high efficiency.
Solehebemaschine
This machine, a Solehebemaschine ("brine-lifting machine"), entered service in 1821. It had two
pressure-operated poppet valves for each cylinder. These engines are brass to resist corrosion
by the salt water. Water pressure engines must be designed taking into account the
incompressibility of water, so both valves must not close at the same time, and abrupt changes
of rate of flow must not be made. Air chambers can be used to eliminate shocks. Georg von
Reichenbach (1771-1826) is much better known as an optical designer than as a mechanical
engineer. He was associated with Joseph Fraunhofer, and they died within days of each other in
1826. He was of an aristocratic family, and was Salinenrat, or manager of the state salt works, in
southeastern Bavaria, which was centered on the town of Reichenhall, now Bad Reichenhall,
near Salzburg.
The name derives from "rich in salt." This famous salt region had salt springs flowing nearly
saturated brine, at 24% to 26% (saturated is 27%) salt, that from ancient times had been
evaporated over wood fires. A brine pipeline to Traunstein was constructed in 1617-1619, since
wood fuel for evaporating the brine was exhausted in Reichenhall. The pipeline was further
extended to Rosenheim, where there was turf as well as wood, in 1818-10.
Von Reichenbach is said to have built this pipeline, for which he designed a water-wheel-driven,
four-barrel pump. Maximilian I, King of Bavaria, commissioned von Reichenbach to bring brine
from Berchtesgaden, elevation 530 m, to Reichenhall, elevation 470 m, over a summit 943 m
high. Fresh water was also allowed to flow down to the salt beds, and the brine was then pumped
to the surface. This was a much easier way to mine salt than underground mining.
39
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Forces on Submerged Surfaces
Suppose we want to know the force exerted on a vertical surface of any shape with water on one
side, assuming gravity to act, and the pressure on the surface of the water zero. We have already
solved this problem by a geometrical argument, but
now we apply calculus, which is easier but not as
illuminating.
The simplest case is a rectangular gate of width w, and height h, whose top is a distance H below
the surface of the water.
In this case, the integrations are very easy, and F = gw [(h + H) 2 - h2]/2 = gH (H + 2h)/2 = g
(h + H/2) Hw.
The total force on the gate is equal to its area times the pressure at its center. M = gw [(h + H)
3 - h3]/3 = g (H2/3 + Hh + h2) Hw, so that c = (H2/3 + Hh + h2)/ (h + H/2).
In the simple case of h = 0, c = 2H/3, or two-thirds of the way from the top to the bottom of the
gate. If we take the atmospheric pressure to act not only on the surface of the water, but also the
dry side of the gate, there is no change to this result. This is the reason atmospheric pressure
often seems to have been neglected in solving sub h problems.
Consider a curious rectangular tank, with one side vertical but the opposite side inclined inwards
or outwards.
The horizontal forces exerted by the water on the two sides must be equal and opposite, or the
tank would scoot off. If the side is inclined outward, then there must be a downward vertical force
equal to the weight of the water above it, and passing through the centroid of this water.
If the side is inclined inward, there must be an upward vertical force equal to the weight of the
'missing' water above it. In both cases, the result is demanded by ordinary statics.
40
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Hydrostatic Paradox
What we have here has been called the 'hydrostatic paradox.' It was conceived by the celebrated
Flemish engineer Simon Stevin (1548-1620) of Brugge, the first modern scientist to investigate
the statics of fluids and solids. Consider three tanks with bottoms of equal sizes and equal heights,
filled with water. The pressures at the bottoms are equal, so the vertical force on the bottom of
each tank is the same. But suppose that one tank has vertical sides, one has sides inclined
inward, and third sides inclined outwards. The tanks do not contain the same weight of water, yet
the forces on their bottoms are equal! I am sure that you can spot the resolution of this paradox.
If a volume of fluid is accelerated uniformly, the acceleration can be added to the acceleration of
gravity. A free surface now becomes perpendicular to the total acceleration, and the pressure is
proportional to the distance from this surface. The same can be done for a rotating fluid, where
the centrifugal acceleration is the important quantity. The earth's atmosphere is an example.
When air moves relative to the rotating system, the Coriolis force must also be taken into account.
However, these are dynamic effects and are not strictly a part of hydrostatics.
Buoyancy
Archimedes, so the legend runs, was asked to determine if the goldsmith who made a golden
crown for Hieron, Tyrant of Syracuse, had substituted cheaper metals for gold. The story is told
by Vitruvius. A substitution could not be detected by simply weighing the crown, since it was
craftily made to the same weight as the gold supplied for its construction. Archimedes realized
that finding the density of the crown, that is, the weight per unit volume, would give the answer.
The weight was known, of course, and Archimedes cunningly measured its volume by the amount
of water that ran off when it was immersed in a vessel filled to the brim. By comparing the results
for the crown, and for pure gold, it was found that the crown displaced more water than an equal
weight of gold, and had, therefore, been adulterated.
This story, typical of the charming way science was made more interesting in classical times, may
or may not actually have taken place, but whether it did or not, Archimedes taught that a body
immersed in a fluid lost apparent weight equal to the weight of the fluid displaced, called
Archimedes' Principle. Specific gravity, the ratio of the density of a substance to the density of
water, can be determined by weighing the body in air, and then in water. The specific gravity is
the weight in air divided by the loss in weight when immersed. This avoids the difficult
determination of the exact volume of the sample.
41
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
How Buoyancy Works
To see how buoyancy works, consider a submerged brick, of height h, width w and length l. The
difference in pressure on top and bottom of the brick is gh, so the difference in total force on top
and bottom of the brick is simply (gh) (wl) = gV, where V is the volume of the brick.
The force exerted by the water on the bottom of a boat acts through the center of gravity B of the
displaced volume, while the force exerted by gravity on the boat acts through its own center of
gravity A. This looks bad for the boat, since the boat's c.g. will naturally be higher than the c.g. of
the displaced water, so the boat will tend to capsize. Well, a board floats, and can tell us why.
Should the board start to rotate to one side, the displaced volume immediately moves to that side,
and the buoyant force tends to correct the rotation. A floating body will be stable provided the
line of action of the buoyant force passes through a point M above the c.g. of the body, called the
metacenter, so that there is a restoring couple when the boat heels. A ship with an improperly
designed hull will not float. It is not as easy to make boats as it might appear.
Submarines are yet another application of buoyancy, with their own characteristic problems.
Small neoprene or natural rubber balloons have been used for meteorological observations, with
hydrogen filling. A 10g ceiling balloon was about 17" in diameter when inflated to have a free lift
of 40g. It ascended 480ft the first minute, 670ft in a minute and a half, and 360ft per minute
afterwards, to find cloud ceilings by timing, up to 2500ft, when it subtended about 2' of arc, easily
seen in binoculars.
42
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Large sounding balloons were used to lift a radiosonde and a parachute for its recovery. An
AN/AMT-2 radiosonde of the 1950's weighed 1500g, the paper parachute 100g, and the balloon
350g. The balloon was inflated to give 800g free lift, so it would rise 700-800 ft/min to an altitude
of about 50,000 ft (15 km) before it burst. This balloon was about 6 ft in diameter when inflated at
the surface, 3 ft in diameter before inflation. The information was returned by radio telemetry, so
the balloon did not have to be followed optically. Of intermediate size was the pilot balloon, which
was followed with a theodolite to determine wind directions and speeds. At night, a pilot balloon
could carry a light for ceiling determinations.
Weather Balloons
The greatest problem with using hydrogen for lift is that it diffuses rapidly through many
substances. Weather balloons had to be launched promptly after filling, or the desired free lift
would not be obtained. Helium is a little better in this respect, but it also diffuses rapidly. The lift
obtained with helium is almost the same as with hydrogen (density 4 compared to 2, where air is
28.97). However, helium is exceedingly rare, and only its unusual occurrence in natural gas from
Kansas makes it available. Great care must be taken when filling balloons with hydrogen to avoid
sparks and the accumulation of hydrogen in air, since hydrogen is exceedingly flammable and
explosive over a wide range of concentrations. Helium has the great advantage that it is not
inflammable.
The hydrogen for filling weather balloons came from compressed gas in cylinders, from the
reaction of granulated aluminum with sodium hydroxide and water, or from the reaction of calcium
hydroxide with water. The chemical reactions are 2Al + 2NaOH + 2H2O 2NaAlO2 + 3H2, or
CaH2 + 2H2O Ca (OH) 2 + 2H2. In the first, silicon or zinc could be used instead of aluminum,
and in the second, any similar metal hydride. Both are rather expensive sources of hydrogen, but
very convenient when only small amounts are required. Most hydrogen is made from the catalytic
decomposition of hydrocarbons, or the reaction of hot coke with steam.
Electrolysis of water is an expensive source, since more energy is used than is recovered with
the hydrogen. Any enthusiasm for a "hydrogen economy" should be tempered by the fact that
there are no hydrogen wells, and all the hydrogen must be made with an input of energy usually
greater than that available from the hydrogen, and often with the appearance of carbon. Although
about 60,000 Btu/lb is available from hydrogen, compared to 20,000 Btu/lb from gasoline,
hydrogen compressed to 1000 psi requires 140 times as much volume for the same weight as
gasoline. For the energy content of a 13-gallon gasoline tank, a 600-gallon hydrogen tank would
be required. The critical temperature of hydrogen is 32K, so liquid storage is out of the question
for general use.
43
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Variations
Things are complicated by the variation of the density of water with temperature, and also by the
confusion that gave us the distinction between cc and ml. The milliliter is the volume of 1.0 g of
water at 4C, by definition. The actual volume of 1.0 g of water at 4C is 0.999973 cm3 by
measurement. Since most densities are not known, or needed, to more than three significant
figures, it is clear that this difference is of no practical importance, and the ml can be taken equal
to the cc. The density of water at 0C is 0.99987 g/ml, at 20 0.99823, and at 100C 0.95838. The
temperature dependence of the density may have to be taken into consideration in accurate work.
Mercury, while we are at it, has a density 13.5955 at 0C, and 13.5461 at 20C.
The basic idea in finding specific gravity is to weigh a sample in air, and then immersed in water.
Then the specific gravity is W/ (W - W'), if W is the weight in air, and W' the weight immersed. The
denominator is just the buoyant force, the weight of a volume of water equal to the volume of the
sample. This can be carried out with an ordinary balance, but special balances, such as the Jolly
balance, have been created specifically for this application. Adding an extra weight to the sample
allows measurement of specific gravities less than 1.
Pycnometer
A pycnometer is a flask with a close-fitting ground glass stopper with a fine hole through it, so a
given volume can be accurately obtained. The name comes from the Greek word meaning
"density." If the flask is weighed empty, full of water, and full of a liquid whose specific gravity is
desired, the specific gravity of the liquid can easily be calculated. A sample in the form of a
powder, to which the usual method of weighing cannot be used, can be put into the pycnometer.
The weight of the powder and the weight of the displaced water can be determined, and from
them the specific gravity of the powder.
The specific gravity of a liquid can be found with a collection of small weighted, hollow spheres
that will just float in certain specific gravities. The closest spheres that will just float and just sink
put limits on the specific gravity of the liquid. This method was once used in Scotland to determine
the amount of alcohol in distilled liquors. Since the density of a liquid decreases as the
temperature increases, the spheres that float are an indication of the temperature of the liquid.
Galileo's thermometer worked this way.
Hydrometer
A better instrument is the hydrometer, which consists of a weighted float and a calibrated stem
that protrudes from the liquid when the float is entirely immersed. A higher specific gravity will
result in a greater length of the stem above the surface, while a lower specific gravity will cause
the hydrometer to float lower.
The small cross-sectional area of the stem makes the instrument very sensitive. Of course, it must
be calibrated against standards. In most cases, the graduations ("degrees") are arbitrary and
reference is made to a table to determine the specific gravities. Hydrometers are used to
determine the specific gravity of lead-acid battery electrolyte, and the concentration of antifreeze
compounds in engine coolants, as well as the alcohol content of whiskey.
44
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pascals Law
The foundation of modern hydraulics was established when Pascal discovered that pressure in a
fluid acts equally in all directions. This pressure acts at right angles to the containing surfaces. If
some type of pressure gauge, with an exposed face, is placed beneath the surface of a liquid at
a specific depth and pointed in different directions, the pressure will read the same. Thus, we can
say that pressure in a liquid is independent of direction.
Pressure due to the weight of a liquid, at any level, depends on the depth of the fluid from the
surface. If the exposed face of the pressure gauges are moved closer to the surface of the liquid,
the indicated pressure will be less. When the depth is doubled, the indicated pressure is doubled.
Thus the pressure in a liquid is directly proportional to the depth. Consider a container with vertical
sides that is 1 foot long and 1 foot wide. Let it be filled with water 1 foot deep, providing 1 cubic
foot of water. 1 cubic foot of water weighs 62.4 pounds. Using this information and equation, P =
F/A, we can calculate the pressure on the bottom of the container.
Since there are 144 square inches in 1 square foot, this can be stated as follows: the weight of a
column of water 1 foot high, having a cross-sectional area of 1 square inch, is 0.433 pound. If the
depth of the column is tripled, the weight of the column will be 3 x 0.433, or 1.299 pounds, and
the pressure at the bottom will be 1.299 lb/in2 (psi), since pressure equals the force divided by the
area.
Thus, the pressure at any depth in a liquid is equal to the weight of the column of liquid at that
depth divided by the cross-sectional area of the column at that depth. The volume of a liquid that
produces the pressure is referred to as the fluid head of the liquid. The pressure of a liquid due to
its fluid head is also dependent on the density of the liquid.
Gravity
Gravity is one of the four forces of nature. The strength of the gravitational force between two
objects depends on their masses. The more massive the objects are, the stronger the gravitational
attraction. When you pour water out of a container, the earth's gravity pulls the water towards the
ground. The same thing happens when you put two buckets of water, with a tube between them,
at two different heights. You must work to start the flow of water from one bucket to the other, but
then gravity takes over and the process will continue on its own.
Gravity, applied forces, and atmospheric pressure are static factors that apply equally to fluids at
rest or in motion, while inertia and friction are dynamic factors that apply only to fluids in motion.
The mathematical sum of gravity, applied force, and atmospheric pressure is the static pressure
obtained at any one point in a fluid at any given time.
Static Pressure
Static pressure exists in addition to any dynamic factors that may also be present at the same
time. Pascals law states that a pressure set up in a fluid acts equally in all directions and at right
angles to the containing surfaces. This covers the situation only for fluids at rest or practically at
rest. It is true only for the factors making up static head.
45
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Obviously, when velocity becomes a factor it must have a direction, and as previously explained,
the force related to the velocity must also have a direction, so that Pascals law alone does not
apply to the dynamic factors of fluid power.
The dynamic factors of inertia and friction are related to the static factors. Velocity head and
friction head are obtained at the expense of static head. However, a portion of the velocity head
can always be reconverted to static head. Force, which can be produced by pressure or head
when dealing with fluids, is necessary to start a body moving if it is at rest, and is present in some
form when the motion of the body is arrested; therefore, whenever a fluid is given velocity, some
part of its original static head is used to impart this velocity, which then exists as velocity head.
Volume and velocity of flow are often considered together. With other conditions unalteredthat
is, with volume of input unchangedthe velocity of flow increases as the cross section or size of
the pipe decreases, and the velocity of flow decreases as the cross section increases. For
example, the velocity of flow is slow at wide parts of a stream and rapid at narrow parts, yet the
volume of water passing each part of the stream is the same.
Bernoulli's Principle
Bernoulli's principle thus says that a rise (fall) in pressure in a flowing fluid must always be
accompanied by a decrease (increase) in the speed, and conversely, if an increase (decrease)
in, the speed of the fluid results in a decrease (increase) in the pressure.
This is at the heart of a number of everyday phenomena. As a very trivial example, Bernoullis
principle is responsible for the fact that a shower curtain gets sucked inwards'' when the water
is first turned on. What happens is that the increased
water/air velocity inside the curtain (relative to the still
air on the other side) causes a pressure drop.
46
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Bernoullis principle also tells us why windows tend to explode, rather than implode in hurricanes:
the very high speed of the air just outside the window causes the pressure just outside to be much
less than the pressure inside, where the air is still. The difference in force pushes the windows
outward, and hence they explode. If you know that a hurricane is coming it is therefore better to
open as many windows as possible, to equalize the pressure inside and out.
Another example of Bernoulli's principle at work is in the lift of aircraft wings and the motion of
curve balls'' in baseball.
In both cases the design is such as to create a speed differential of the flowing air past the object
on the top and the bottom - for aircraft wings this comes from the movement of the flaps, and for
the baseball it is the presence of ridges.
Such a speed differential leads to a pressure difference between the top and bottom of the object,
resulting in a net force being exerted, either upwards or downwards.
47
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
48
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Understanding the Venturi
It is not easy to understand the reason low pressure occurs in the small diameter area of the
venturi. This explanation may seem to help the principle.
It is clear that all the flow must pass from the larger section to the smaller section. Or in other
words, the flow rate will remain the same in the large and small portions of the tube. The flow rate
is the same rate, but the velocity changes. The velocity is greater in the small portion of the tube.
There is a relationship between the pressure energy and the velocity energy; if velocity increases
the pressure energy must decrease.
This is known as the principle of conservation of energy at work which is also Bernoulli's law. This
is similar to the soapbox derby car in the illustration at the top of a hill. At the top or point, the
elevation of the soapbox derby car is high and the velocity low.
At the bottom the elevation is low and the velocity is high, elevation (potential) energy has been
converted to velocity (kinetic) energy. Pressure and velocity energies behave in the same way. In
the large part of the pipe the pressure is high and velocity is low, in the small part, pressure is low
and velocity high.
49
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
50
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Backflow Section Introduction
Backflow Prevention, also referred to as Cross-Connection Control, addresses a serious health
issue. This issue was addressed on the federal level by passage of the "Federal Safe Drinking
Water Act" as developed by the Environmental Protection Agency (E.P.A.) and passed into law
on December 16, 1974.
This Act tasked each state with primary enforcement responsibility for a program to assure access
to safe drinking water by all citizens. Such state program regulations as adopted are required to
be at least as stringent as the federal regulations as developed and enforced by the E.P.A.
The official definition of a cross-connection is "the link or channel connecting a source of pollution
with a potable water supply." There are two distinct levels of concern with this issue. The first is
protection of the general public and the second is protection of persons subject to such risks
involving service to a single customer, be that customer an individual residence or business.
Sources of pollution which may result in a danger to health are not always obvious and such
cross-connections are certainly not usually intentional. They are usually the result of oversight or
a non-professional installation.
As source examples, within a business environment the pollutant source may involve the
unintentional cross-connection of internal or external piping with chemical processes or a heating
boiler.
Another potential hazard source within any environment may be a cross-connection of piping
involving a water well located on the property. This is a special concern with older residences or
businesses, which may have been served by well water prior to connection to the developed
water system. There are many other
potential sources of pollutant
hazards.
Control of cross-connections is
possible but only through
knowledge and vigilance. Public
education is essential, for many that
are educated in piping and
plumbing installations fail to
recognize cross-connection
dangers.
51
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Actual Backflow Events
Paraquat
In June 1983, "yellow gushy stuff" poured from some faucets in the Town of Woodsboro,
Maryland. Town personnel notified the County Health Department and the State Water
Supply Division. The State dispatched personnel to take water samples for analysis and
placed a ban on drinking the Town's water.
Firefighters warned residents not to use the water for drinking, cooking, bathing, or any
other purpose except flushing toilets. The Town began flushing its water system. An
investigation revealed that the powerful agricultural herbicide Paraquat had backflowed
into the Town's water system.
Someone left open a gate valve between an agricultural herbicide holding tank and the
Town's water system and, thus, created a cross-connection. Coincidentally, water
pressure in the Town temporarily decreased due to failure of a pump in the Town's water
system. The herbicide Paraquat was backsiphoned into the Town's water system. Upon
restoration of pressure in the Town's water system, Paraquat flowed throughout much of
the Town's water system. Fortunately, this incident did not cause any serious illness or
death. The incident did, however, create an expensive burden on the Town. Tanker trucks
were used temporarily to provide potable water, and the Town flushed and sampled its
water system extensively.
Mortuary
The chief plumbing inspector in a large southern city received a telephone call advising
that blood was coming from drinking fountains at a mortuary (i.e., a funeral home).
Plumbing and health inspectors went to the scene and found evidence that blood had
been circulating in the potable water system within the funeral home. They immediately
ordered the funeral home cut off from the public water system at the meter.
City water and plumbing officials did not think that the water contamination problem had
spread beyond the funeral home, but they sent inspectors into the neighborhood to check
for possible contamination. Investigation revealed that blood had backflowed through a
hydraulic aspirator into the potable water system at the funeral home.
The funeral home had been using a hydraulic aspirator to drain fluids from bodies as part
of the embalming process. The aspirator was directly connected to a faucet at a sink in
the embalming room. Water flow through the aspirator created suction used to draw body
fluids through a needle and hose attached to the aspirator. When funeral home personnel
used the aspirator during a period of low water pressure, the potable water system at the
funeral home became contaminated. Instead of body fluids flowing into the wastewater
system, they were drawn in the opposite direction--into the potable water system.
U.S. Environmental Protection Agency, Cross-Connection Control Manual, 1989
52
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Recent Backflow Situations
Oregon 1993
Water from a drainage pond, used for lawn irrigation, is pumped into the potable water
supply of a housing development.
California 1994
A defective backflow device in the water system of the County Courthouse apparently
caused sodium nitrate contamination that sent 19 people to the hospital.
Nebraska 1994
While working on a chiller unit of an air conditioning system at a nursing home, a hole in
the coil apparently allowed Freon to enter the circulating water, and from there into the
city water system.
California 1994
The blue tinted water in a pond at an amusement park backflowed into the city water
system and caused colored water to flow from homeowners faucets.
California 1994
A film company shooting a commercial for television accidentally introduced a chemical
into the potable water system.
Iowa 1994
A backflow of water from the Capitol Building chilled water system contaminates potable
water with Freon.
Indiana 1994
Water main break caused a drop in water pressure, allowing anti-freeze from an air
conditioning unit to backsiphon into the potable water supply.
Washington 1994
An Ethylene Glycol cooling system was illegally connected to the domestic water supply
at a veterinarian hospital.
Ohio 1994
An ice machine connected to a sewer sickened dozens of people attending a
convention.
53
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Cross-Connection Terms
Cross-connection
A cross-connection is any temporary or permanent connection between a public water
system or consumers potable (i.e., drinking) water system and any source or system
containing nonpotable water or other substances.
An example is the piping between a public water system or consumers potable water
system and an auxiliary water system, cooling system, or irrigation system.
Several cross-connection have been made to soda machines, the one to worry about is
when you have a copper water line hooked to CO2 without a backflow preventer.
The reason is that the CO2 will mix in the water and create copper carbonic acid, which
can be deadly. This is one reason that you will see clear plastic lines at most soda
machines and no copper lines. Most codes require a stainless steel RP backflow
assembly at soda machines.
54
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Common Cross-Connections
55
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Backflow
Backflow is the undesirable reversal of flow of nonpotable water or other substances
through a cross-connection and into the piping of a public water system or consumers
potable water system. There are two types of backflow--backpressure and
backsiphonage.
Backsiphonage
56
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Backsiphonage
Backsiphonage is backflow caused by a negative pressure (i.e., a vacuum or partial
vacuum) in a public water system or consumers potable water system. The effect is
similar to drinking water through a straw.
Backsiphonage can occur when there is a stoppage of water supply due to nearby
firefighting, a break in a water main, etc.
Every day, our public water system has several backsiphonage occurrences, think of
people that use water driven equipment, from a device that drains water-beds to pesticide
applicators.
Backpressure is rarer, but does happen in areas of high elevation, like tall buildings or
buildings with pumps. A good example is the pressure exerted by a building that is 100
feet tall is about 43 PSI; the water main feeding the building is at 35 PSI. The water will
flow back to the water main. Never drink water or coffee inside a funeral home, vet clinic
or hospital.
57
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Backpressure
Reductions in potable water supply pressure occur whenever the amount of water being
used exceeds the amount of water being supplied, such as during water line flushing,
firefighting, or breaks in water mains.
58
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Backpressure Examples
Booster pumps, pressure vessels, elevation, heat
Here we see the backpressure of salt water back into the public water system
from a ships pressure pump. Most water providers are now requiring a RP
assembly at the hydrant.
Some type of debris will keep the device from working properly.
59
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Types of Backflow Prevention Methods and Assemblies
Backflow Devices
Cross connections must either be physically disconnected or have an approved backflow
prevention device installed to protect the public water system. There are five types of
approved devices/methods:
1. Air gap- Is not really a device but is a method.
2. Atmospheric vacuum breaker
3. Pressure vacuum breaker
4. Double check valve
5. Reduced pressure principle backflow preventer (RP device)
The type of device selected for a particular installation depends on several factors. First,
the degree of hazard must be assessed. A high hazard facility is one in which a cross
connection could be hazardous to health, such as a chrome plating shop or a sewage
treatment plant. A low hazard situation is one in which a cross connection would cause
only an aesthetic problem such as a foul taste or odor.
60
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
61
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
62
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
63
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
64
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
65
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
66
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
67
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
68
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
69
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
70
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Operation Section
Distinguish between discharge head, total head, suction head, and suction lift.
Describe cavitation.
71
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
72
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A centrifugal pump has two main components:
I. A rotating component comprised of an impeller and a shaft
II. A stationary component comprised of a casing, casing cover, and bearings.
73
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
General Pumping Fundamentals
First, suction lift is when the level of water to be pumped is below the centerline of the
pump. Sometimes suction lift is also referred to as negative suction head.
The ability of the pump to lift water is the result of a partial vacuum created at the center
of the pump.
This works similar to sucking soda from a straw. As you gently suck on a straw, you are
creating a vacuum or a pressure differential. Less pressure is exerted on the liquid inside
the straw, so that the greater pressure is exerted on the liquid around the outside of the
straw, causing the liquid in the straw to move up. By sucking on the straw, this allows
atmospheric pressure to move the liquid.
Look at the diagram illustrated as 1. The foot valve is located at the end of the suction
pipe of a pump. It opens to allow water to enter the suction side, but closes to prevent
water from passing back out of the bottom end.
The suction side of pipe should be one diameter larger than the pump inlet. The required
eccentric reducer should be turned so that the top is flat and the bottom tapered.
Notice in illustration 2 that the liquid is above the level of the pump. Sometimes this is referred
to as flooded suction or suction head situations.
74
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Definitions (Larger Glossary in the rear of this manual)
Fluid: Any substance that can be pumped such as oil, water, refrigerant, or even air.
Gasket: Flat material that is compressed between two flanges to form a seal.
Gland follower: A bushing used to compress the packing in the stuffing box and to control leakoff.
Gland sealing line: A line that directs sealing fluid to the stuffing box.
Horizontal pumps: Pumps in which the center line of the shaft is horizontal.
Impeller: The part of the pump that increases the speed of the fluid being handled.
Key: A rectangular piece of metal that prevents the impeller from rotating on the shaft.
Lantern ring: A metal ring located between rings of packing that distributes gland sealing fluid.
Mechanical seal: A mechanical device that seals the pump stuffing box.
Mixed flow pump: A pump that uses both axial-flow and radial-flow components in one
impeller.
Positive displacement pumps: Pumps that move fluids by physically displacing the fluid inside
the pump.
Radial bearings: Bearings that prevent shaft movement in any direction outward from the cen-
ter line of the pump.
Rotor: The rotating parts, usually including the impeller, shaft, bearing housings, and all other
parts included between the bearing housing and the impeller.
75
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Score: To cause lines, grooves, or scratches.
Shaft: A cylindrical bar that transmits power from the driver to the pump impeller.
Slop drain: The drain from the area that collects leak-off from the stuffing box.
Stethoscope: A metal device that can amplify and pinpoint pump sounds.
Strainer: A device that retains solid pieces while letting liquids through.
Stuffing box: The area of the pump where the shaft penetrates the casing.
Suction eye: The place where fluid enters the pump impeller.
Throat bushing: A bushing at the bottom of the stuffing box that prevents packing from being
pushed out of the stuffing box into the suction eye of the impeller.
Thrust bearings: Bearings that prevent shaft movement back and forth in the same direction as
the center line of the shaft.
Vanes: The parts of the impeller that push and increase the speed of the fluid in the pump.
Vertical pumps: Pumps in which the center line of the shaft runs vertically.
Volute: The part of the pump that changes the speed of the fluid into pressure.
Wearing rings: Replaceable rings on the impeller or the casing that wear as the pump oper-
ates.
76
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pumps Question 6
Pumps are used to move or raise fluids. They are not only very useful, but are excellent examples
of hydrostatics. Pumps are of two general types, hydrostatic or positive displacement pumps, and
pumps depending on dynamic forces, such as centrifugal pumps. Here we will only consider
positive displacement pumps, which can be understood purely by hydrostatic considerations.
They have a piston (or equivalent) moving in a closely-fitting cylinder and forces are exerted on
the fluid by motion of the piston.
We have already seen an important example of this in the hydraulic lever or hydraulic press, which
we have called quasi-static. The simplest pump is the syringe, filled by withdrawing the piston and
emptied by pressing it back in, as its port is immersed in the fluid or removed from it.
More complicated pumps have valves allowing them to work repetitively. These are usually check
valves that open to allow passage in one direction, and close automatically to prevent reverse
flow. There are many kinds of valves, and they are usually the most trouble-prone and
complicated part of a pump. The force pump has two check valves in the cylinder, one for supply
and the other for delivery. The supply valve opens when the cylinder volume increases, the
delivery valve when the cylinder volume decreases.
The lift pump has a supply valve and a valve in the piston that allows the liquid to pass around it
when the volume of the cylinder is reduced. The delivery in this case is from the upper part of the
cylinder, which the piston does not enter.
77
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Diaphragm pumps are force pumps in which the oscillating diaphragm takes the place of the
piston. The diaphragm may be moved mechanically, or by the pressure of the fluid on one side of
the diaphragm.
Some positive displacement pumps are shown below. The force and lift pumps are typically used
for water. The force pump has two valves in the cylinder, while the lift pump has one valve in the
cylinder and one in the piston. The maximum lift, or "suction," is determined by the atmospheric
pressure, and either cylinder must be within this height of the free surface. The force pump,
however, can give an arbitrarily large pressure to the discharged fluid, as in the case of a diesel
engine injector. A nozzle can be used to convert the pressure to velocity, to produce a jet, as for
firefighting. Fire fighting force pumps usually have two cylinders feeding one receiver alternately.
The air space in the receiver helps to make the water pressure uniform.
The three pumps below are typically used for air, but would be equally applicable to liquids. The
Roots blower has no valves, their place taken by the sliding contact between the rotors and the
housing. The Roots blower can either exhaust a receiver or provide air under moderate pressure,
in large volumes. The Bellows is a very old device, requiring no accurate machining. The single
valve is in one or both sides of the expandable chamber. Another valve can be placed at the
nozzle if required. The valve can be a piece of soft leather held close to holes in the chamber.
The Bicycle pump uses the valve on the valve stem of the tire or inner tube to hold pressure in
the tire. The piston, which is attached to the discharge tube, has a flexible seal that seals when
the cylinder is moved to compress the air, but allows air to pass when the movement is reversed.
Diaphragm and vane pumps are not shown, but they act the same way by varying the volume of
a chamber, and directing the flow with check valves.
78
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Types of Pumps Question 23
The family of pumps comprises a large number of types based on application and capabilities.
The two major groups of pumps are dynamic and positive displacement.
A Positive Displacement Pump, unlike a Centrifugal Pump, will produce the same flow at a given
RPM no matter what the discharge pressure is. A Positive Displacement Pump cannot be
operated against a closed valve on the discharge side of the pump, i.e. it does not have a shut-
off head like a Centrifugal Pump does. If a Positive Displacement Pump is allowed to operate
against a closed discharge valve it will continue to produce flow which will increase the pressure
in the discharge line until either the line bursts or the pump is severely damaged or both.
Vane Gear
Piston Lobe
79
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Single Rotator
Component Description
Vane The vane(s) may be blades, buckets, rollers, or slippers that cooperate
with a dam to draw fluid into and out of the pump chamber.
Piston Fluid is drawn in and out of the pump chamber by a piston(s) reciprocating
within a cylinder(s) and operating port valves.
Flexible Member Pumping and sealing depends on the elasticity of a flexible member(s) that
may be a tube, vane, or a liner.
Single Screw Fluid is carried between rotor screw threads as they mesh with internal
threads on the stator.
Multiple Rotator
Component Description
Gear Fluid is carried between gear teeth and is expelled by the meshing of the
gears that cooperate to provide continuous sealing between the pump inlet
and outlet.
Lobe Fluid is carried between rotor lobes that cooperate to provide continuous
sealing between the pump inlet and outlet.
Circumferential piston Fluid is carried in spaces between piston surfaces not requiring contacts
between rotor surfaces.
Multiple Screw Fluid is carried between rotor screw threads as they mesh.
What kind of mechanical device do you think is used to provide this positive displacement
in the:
Plunger pump?
Diaphragm pump?
In the same way, the progressing cavity and the screw are two other types of mechanical action
that can be used to provide movement of the liquid through the pump.
All discharge valves must be open before the pump is started, to prevent any fast build-up of
pressure that could damage the pump.
80
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Diaphragm Pumps
In this type of pump, a diaphragm provides the mechanical action used to force liquid from the
suction to the discharge side of the pump. The advantage the diaphragm has over the plunger is
that the diaphragm pump does not come in contact with moving metal. This can be important
when pumping abrasive or corrosive materials.
Pump Categories
Let's cover the essentials first. The key to the whole operation is, of course, the pump. And
regardless of what type it is (reciprocating piston, centrifugal, turbine or jet-ejector, for either
shallow or deep well applications), its purpose is to move water and generate the delivery force
we call pressure. Sometimes with centrifugal pumps in particular pressure is not referred to
in pounds per square inch but rather as the equivalent in elevation, called head. No matter; head
in feet divided by 2.31 equals pressure, so it's simple enough to establish a common figure.
Pumps may be classified on the basis of the application they serve. All pumps may be divided
into two major categories: (1) dynamic, in which energy is continuously added to increase the fluid
velocities within the machine, and (2) displacement, in which the energy is periodically added by
application of force.
81
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
.
82
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Basic Water Pump Question 45
The water pump commonly found in our systems is centrifugal pumps. These pumps work by
spinning water around in a circle inside a cylindrical pump housing. The pump makes the water
spin by pushing it with an impeller. The blades of this impeller project outward from an axle like
the arms of a turnstile and, as the impeller spins, the water spins with it. As the water spins, the
pressure near the outer edge of the pump housing becomes much higher than near the center of
the impeller.
There are many ways to understand this rise in pressure, and here are two:
First, you can view the water between the impeller blades as an object traveling in a circle. Objects
do not naturally travel in a circle--they need an inward force to cause them to accelerate inward
as they spin.
Without such an inward force, an object will travel in a straight line and will not complete the circle.
In a centrifugal pump, that inward force is provided by high-pressure water near the outer edge
of the pump housing. The water at the edge of the pump pushes inward on the water between
the impeller blades and makes it possible for that water to travel in a circle. The water pressure
at the edge of the turning impeller rises until it is able to keep water circling with the impeller
blades.
You can also view the water as an incompressible fluid, one that obeys Bernoulli's equation in the
appropriate contexts. As water drifts outward between the impeller blades of the pump, it must
move faster and faster because its circular path is getting larger and larger. The impeller blades
cause the water to move faster and faster. By the time the water has reached the outer edge of
the impeller, it is moving quite fast. However, when the water leaves the impeller and arrives at
the outer edge of the cylindrical pump housing, it slows down.
83
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Here is where Bernoulli's equation figures in. As the water slows down and its kinetic energy
decreases, that water's pressure potential energy increases (to conserve energy). Thus, the
slowing is accompanied by a pressure rise. That is why the water pressure at the outer edge of
the pump housing is higher than the water pressure near the center of the impeller. When water
is actively flowing through the pump, arriving through a hole near the center of the impeller and
leaving through a hole near the outer edge of the pump housing, the pressure rise between center
and edge of the pump is not as large.
84
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
85
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
86
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Self-priming Pump:
A pump that does not require priming or initial filling with liquid. The pump casing carries
a reserve of water that helps create a vacuum that will lift the fluid from a low source.
87
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Stuffing Box:
The joint that seals the fluid in the pump stopping it from coming out between the casing
and the pump shaft. The following image (source: the Pump Handbook by McGraw-Hill)
shows a typical stuffing box with gland packing. The function of packing is to control
leakage and not to eliminate it completely.
The packing must be lubricated, and a flow from 40 to 60 drops per minute out of the
stuffing box must be maintained for proper lubrication. This makes this type of seal unfit
for situations where leakage is unacceptable but they are very common in large primary
sector industries such a mining and pulp and paper.
88
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
It is not easy to understand why low pressure occurs in the small diameter area of the
venturi. I have come up with this explanation that seems to help.
It is clear that all the flow must pass from the larger section to the smaller section. Or in
other words, the flow rate will remain the same in the large and small portions of the tube.
The flow rate is the same, but the velocity changes. The velocity is greater in the small
portion of the tube.
There is a relationship between the pressure energy and the velocity energy; if velocity
increases the pressure energy must decrease. This is the principle of conservation of
energy at work which is also Bernoulli's law. In the large part of the pipe the pressure is
high and velocity is low, in the small part, pressure is low and velocity high.
89
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Viscous drag pump: A pump whose impeller has no vanes but relies on fluid contact
with a flat rotating plate turning at high speed to move the liquid.
90
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Types of Water Pumps
The most common type of water pumps used for municipal and domestic water supplies are
variable displacement pumps. A variable displacement pump will produce at different rates
relative to the amount of pressure or lift the pump is working against. Centrifugal pumps are
variable displacement pumps that are by far used the most. The water production well industry
almost exclusively uses Turbine pumps, which are a type of centrifugal pump.
The turbine pump utilizes impellers enclosed in single or multiple bowls or stages to lift water by
centrifugal force. The impellers may be of either a semi-open or closed type. Impellers are
rotated by the pump motor, which provides the horsepower needed to overcome the pumping
head. A more thorough discussion of how these and other pumps work is presented later in this
section. The size and number of stages, horsepower of the motor and pumping head are the key
components relating to the pumps lifting capacity.
Vertical turbine pumps are commonly used in groundwater wells. These pumps are driven by a
shaft rotated by a motor on the surface. The shaft turns the impellers within the pump housing
while the water moves up the column.
This type of pumping system is also called a line-shaft turbine. The rotating shaft in a line shaft
turbine is actually housed within the column pipe that delivers the water to the surface. The size
of the column, impeller, and bowls are selected based on the desired pumping rate and lift
requirements.
Column pipe sections can be threaded or coupled together while the drive shaft is coupled and
suspended within the column by spider bearings. The spider bearings provide both a seal at the
column pipe joints and keep the shaft aligned within the column. The water passing through the
column pipe serves as the lubricant for the bearings. Some vertical turbines are lubricated by oil
rather than water. These pumps are essentially the same as water lubricated units; only the drive
shaft is enclosed within an oil tube.
Food grade oil is supplied to the tube through a gravity feed system during operation. The oil
tube is suspended within the column by spider flanges, while the line shaft is supported within the
oil tube by brass or redwood bearings. A continuous supply of oil lubricates the drive shaft as it
proceeds downward through the oil tube.
A small hole located at the top of the pump bow unit allows excess oil to enter the well. This
results in the formation of an oil film on the water surface within oil-lubricated wells. Careful
operation of oil lubricated turbines is needed to ensure that the pumping levels do not drop enough
to allow oil to enter the pump. Both water and oil lubricated turbine pump units can be driven by
electric or fuel powered motors. Most installations use an electric motor that is connected to the
drive shaft by a keyway and nut. However, where electricity is not readily available, fuel powered
engines may be connected to the drive shaft by a right angle drive gear. Also, both oil and water
lubricated systems will have a strainer attached to the intake to prevent sediment from entering
the pump.
When the line shaft turbine is turned off, water will flow back down the column, turning the
impellers in a reverse direction. A pump and shaft can easily be broken if the motor were to turn
on during this process. This is why a time delay or ratchet assembly is often installed on these
motors to either prevent the motor from turning on before reverse rotation stops or simply not
allow it to reverse at all.
91
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
There are three main types of diaphragm pumps: Question 79
In the first type, the diaphragm is sealed with one side in the fluid to be pumped, and the other in
air or hydraulic fluid. The diaphragm is flexed, causing the volume of the pump chamber to
increase and decrease. A pair of non-return check valves prevents reverse flow of the fluid.
As described above, the second type of diaphragm pump works with volumetric positive
displacement, but differs in that the prime mover of the diaphragm is neither oil nor air; but is
electro-mechanical, working through a crank or geared motor drive. This method flexes the
diaphragm through simple mechanical action, and one side of the diaphragm is open to air. The
third type of diaphragm pump has one or more unsealed diaphragms with the fluid to be pumped
on both sides. The diaphragm(s) again are flexed, causing the volume to change.
When the volume of a chamber of either type of pump is increased (the diaphragm moving up),
the pressure decreases, and fluid is drawn into the chamber. When the chamber pressure later
increases from decreased volume (the diaphragm moving down), the fluid previously drawn in is
forced out. Finally, the diaphragm moving up once again draws fluid into the chamber, completing
the cycle. This action is similar to that of the cylinder in an internal combustion engine.
Cavitation
Cavitation is defined as the phenomenon of formation of vapor bubbles of a flowing liquid in a
region where the pressure of the liquid falls below its vapor pressure. Cavitation is usually divided
into two classes of behavior: inertial (or transient) cavitation and non-inertial cavitation. Inertial
cavitation is the process where a void or bubble in a liquid rapidly collapses, producing a shock
wave. Such cavitation often occurs in pumps, propellers, impellers, and in the vascular tissues of
plants. Non-inertial cavitation is the process in which a bubble in a fluid is forced to oscillate in
size or shape due to some form of energy input, such as an acoustic field. Such cavitation is often
employed in ultrasonic cleaning baths and can also be observed in pumps, propellers etc.
Cavitation is, in many cases, an undesirable occurrence. In devices such as propellers and
pumps, cavitation causes a great deal of noise, damage to components, vibrations, and a loss of
efficiency. When the cavitation bubbles collapse, they force liquid energy into very small volumes,
thereby creating spots of high temperature and emitting shock waves, the latter of which are a
source of noise. The noise created by cavitation is a particular problem for military submarines,
as it increases the chances of being detected by passive sonar.
Although the collapse of a cavity is a relatively low-energy event, highly localized collapses can
erode metals, such as steel, over time. The pitting caused by the collapse of cavities produces
great wear on components and can dramatically shorten a propeller's or pump's lifetime. After a
surface is initially affected by cavitation, it tends to erode at an accelerating pace. The cavitation
pits increase the turbulence of the fluid flow and create crevasses that act as nucleation sites for
additional cavitation bubbles. The pits also increase the component's surface area and leave
behind residual stresses. This makes the surface more prone to stress corrosion.
Impeller
An impeller is a rotating component of a centrifugal pump, usually made of iron, steel, aluminum
or plastic, which transfers energy from the motor that drives the pump to the fluid being pumped
by accelerating the fluid outwards from the center of rotation. The velocity achieved by the impeller
transfers into pressure when the outward movement of the fluid is confined by the pump casing.
Impellers are usually short cylinders with an open inlet (called an eye) to accept incoming fluid,
vanes to push the fluid radically, and a splined center to accept a driveshaft.
92
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Progressing Cavity Pump
In this type of pump, components referred to as a rotor and an elastic stator provide the
mechanical action used to force liquid from the suction side to the discharge side of the pump. As
the rotor turns within the stator, cavities are formed which progress from the suction to the
discharge end of the pump, conveying the pumped material. The continuous seal between the
rotor and the stator helices keeps the fluid moving steadily at a fixed flow rate proportional to the
pump's rotational speed. Progressing cavity pumps are used to pump material very high in solids
content. The progressive cavity pump must never be run dry, because the friction between the
rotor and stator will quickly damage the pump.
This type of pump transfers fluid by means of the progress, through the pump, of a sequence of
small, fixed shape, discrete cavities, as its rotor is turned. This leads to the volumetric flow rate
being proportional to the rotation rate (bi-directionally) and to low levels of shearing being applied
to the pumped fluid. Hence, these pumps have application in fluid metering and pumping of
viscous or shear sensitive materials. It should be noted that the cavities taper down toward their
ends and overlap with their neighbors, so that, in general, no flow pulsing is caused by the arrival
of cavities at the outlet, other than that caused by compression of the fluid or pump components.
The principle of this pumping technique is frequently misunderstood; often it is believed to occur
due to a dynamic effect caused by drag, or friction against the moving teeth of the screw rotor.
However, in reality it is due to sealed cavities, like a piston pump, and so has similar operational
characteristics, such as being able to pump at extremely low rates, even to high pressure,
revealing the effect to be purely positive displacement.
93
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The mechanical layout that causes the cavities to, uniquely, be of fixed dimensions as they move
through the pump, is hard to visualize (its essentially 3D nature renders diagrams quite ineffective
for explanation), but it is accomplished by the preservation in shape of the gap formed between
a helical shaft and a two start, twice the wavelength and double the diameter, helical hole, as the
shaft is "rolled" around the inside surface of the hole. The motion of the rotor being the same as
the smaller gears of a planetary gears system. This form of motion gives rise to the curves called
Hypocycloids.
In order to produce a seal between cavities, the rotor requires a circular cross-section and the
stator an oval one. The rotor so takes a form similar to a corkscrew, and this, combined with the
off-center rotary motion, leads to the name; Eccentric screw pump.
Different rotor shapes and rotor/stator pitch ratios exist, but are specialized in that they don't
generally allow complete sealing, so reducing low speed pressure and flow rate linearity, but
improving actual flow rates, for a given pump size, and/or the pumps solids handling ability.
At a high enough pressure the sliding seals between cavities will leak some fluid rather than
pumping it, so when pumping against high pressures a longer pump with more cavities is more
effective, since each seal has only to deal with the pressure difference between adjacent cavities.
Pumps with between two and a dozen or so cavities exist.
94
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
In operation, progressive cavity pumps are fundamentally fixed flow rate pumps, like piston pumps
and peristaltic pumps. This type of pump needs a fundamentally different understanding to the
types of pumps to which people are more commonly first introduced, namely ones that can be
thought of as generating a pressure. This can lead to the mistaken assumption that all pumps can
have their flow rates adjusted by using a valve attached to their outlet, but with this type of pump
this assumption is a problem, since such a valve will have practically no effect on the flow rate
and completely closing it will involve very high, probably damaging, pressures being generated.
In order to prevent this, pumps are often fitted with cut-off pressure switches, burst disks
(deliberately weak and easily replaced points), or a bypass pipe that allows a variable amount of
a fluid to return to the inlet. With a bypass fitted, a fixed flow rate pump is effectively converted to
a fixed pressure one.
At the points where the rotor touches the stator, the surfaces are generally traveling transversely,
so small areas of sliding contact occur, these areas need to be lubricated by the fluid being
pumped (Hydrodynamic lubrication), this can mean that more torque is required for starting, and
if allowed to operate without fluid, called 'run dry', rapid deterioration of the stator can result.
While progressive cavity pumps offer long life and reliable service transporting thick or lumpy
fluids, abrasive fluids will significantly shorten the life of the stator. However, slurries (particulates
in a medium) can be pumped reliably, as long as the medium is viscous enough to maintain a
lubrication layer around the particles and so provide protection to the stator.
Specific designs involve the rotor of the pump being made of a steel, coated in a smooth hard
surface, normally chromium, with the body (the stator) made of a molded elastomer inside a metal
tube body. The Elastomer core of the stator forms the required complex cavities. The rotor is held
against the inside surface of the stator by angled link arms, bearings (which have to be within the
fluid) allowing it to roll around the inner surface (un-driven). Elastomer is used for the stator to
simplify the creation of the complex internal shape, created by means of casting, and also
improves the quality and longevity of the seals by progressively swelling due to absorption of
water and/or other common constituents of pumped fluids. Elastomer/pumped fluid compatibility
will thus need to be taken into account.
Two common designs of stator are the "Equal-walled" and the "Unequal walled". The latter, having
greater elastomer wall thickness at the peaks, allows larger-sized solids to pass through because
of its increased ability to distort under pressure.
95
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Key Pump Words
NPSH: Net positive suction head - related to how much suction lift a pump can achieve by
creating a partial vacuum. Atmospheric pressure then pushes liquid into the pump. A method of
calculating if the pump will work or not.
S.G.: Specific gravity. The weight of liquid in comparison to water at approx. 20 degrees C (SG
= 1).
Specific Speed: A number which is the function of pump flow, head, efficiency etc. Not used in
day to day pump selection, but very useful, as pumps with similar specific speed will have similar
shaped curves, similar efficiency / NPSH / solids handling characteristics.
Vapor Pressure: If the vapor pressure of a liquid is greater than the surrounding air pressure,
the liquid will boil.
Viscosity: A measure of a liquid's resistance to flow. i.e.: how thick it is. The viscosity determines
the type of pump used, the speed it can run at, and with gear pumps, the internal clearances
required.
Friction Loss: The amount of pressure / head required to 'force' liquid through pipe and
fittings.
96
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Screw or Auger Pump
The Archimedes' screw, Archimedean screw, or screwpump is a machine historically used for
transferring water from a low-lying body of water into irrigation ditches. It was one of several
inventions and discoveries traditionally attributed to Archimedes in the 3rd century BC.
The machine consists of a screw inside a hollow pipe. Some attribute its invention to Archimedes
in the 3rd century BC, while others attribute it to Nebuchadnezzar II in the 7th century BC. A screw
can be thought of as an inclined plane (another simple machine) wrapped around a cylinder.
The screw is turned (usually by a windmill or by manual labor). As the bottom end of the tube
turns, it scoops up a volume of water. This amount of water will slide up in the spiral tube as the
shaft is turned, until it finally pours out from the top of the tube and feeds the irrigation system.
The contact surface between the screw and the pipe does not need to be perfectly water-tight
because of the relatively large amount of water being scooped at each turn with respect to the
angular speed of the screw. Also, water leaking from the top section of the screw leaks into the
previous one and so on. So a sort of equilibrium is achieved while using the machine, thus
preventing a decrease in efficiency.
The "screw" does not necessarily need to turn inside the casing, but can be allowed to turn with
it in one piece.
A screw could be sealed with pitch or some other adhesive to its casing, or, cast as a single piece
in bronze, as some researchers have postulated as being the devices used to irrigate
Nebuchadnezzar II's Hanging Gardens of Babylon. Depictions of Greek and Roman water screws
show the screws being powered by a human treading on the outer casing to turn the entire
apparatus as one piece, which would require that the casing be rigidly attached to the screw.
97
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
In this type of pump, a large screw provides the mechanical action to move the liquid from the
suction side to the discharge side of the pump. Here are some typical characteristics of screw
pumps:
Most screw pumps rotate in the 30 to 60 rpm range, although some screw pumps are
faster.
The slope of the screw is normally either 30 or 38.
The maximum lift for the larger diameter pumps is about 30 feet. The smaller diameter pumps
have lower lift capabilities.
98
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Submersible Pumps
Submersible pumps are in essence very similar to turbine pumps. They both use impellers rotated
by a shaft within the bowls to pump water. However, the pump portion is directly connected to
the motor.
The pump shaft has a keyway in which the splined motor end shaft inserts. The motor is bolted
to the pump housing. The pumps intake is located between the motor and the pump and is
normally screened to prevent sediment from entering the pump and damaging the impellers.
The efficient cooling of submersible motors is very important, so these types of pumps are often
installed such that flow through the well screen can occur upwards past the motor and into the
intake. If the motor end is inserted below the screened interval or below all productive portions
of the aquifer, it will not be cooled, resulting in premature motor failure.
Some pumps may have pump shrouds installed on them to force all the water to move past the
motor to prevent overheating.
The shroud is a piece of pipe that attaches to the pump housing with an open end below the
motor. As with turbine pumps, the size of the bowls and impellers, number of stages, and
horsepower of the motor are adjusted to achieve the desired production rate within the limitations
of the pumping head.
99
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
100
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Understanding the Operation of a Vertical Turbine Pump
Vertical turbine pumps are available in deep well, shallow well, or canned configurations. VHS or
VSS motors will be provided to fulfill environmental requirements. Submersible motors are also
available. These pumps are also suitable industrial, municipal, commercial and agricultural
applications.
Deep well turbine pumps are adapted for use in cased wells or where the water surface is below
the practical limits of a centrifugal pump. Turbine pumps are also used with surface water
systems. Since the intake for the turbine pump is continuously under water, priming is not a
concern. Turbine pump efficiencies are comparable to or greater than most centrifugal pumps.
They are usually more expensive than centrifugal pumps and more difficult to inspect and repair.
The turbine pump has three main parts: (1) the head assembly, (2) the shaft and column assembly
and (3) the pump bowl assembly. The head is normally cast iron and designed to be installed on
a foundation. It supports the column, shaft, and bowl assemblies, and provides a discharge for
the water. It also will support either an electric motor, a right angle gear drive or a belt drive.
Bowl Assembly
The bowl assembly is the heart of the vertical turbine pump. The impeller and diffuser type casing
is designed to deliver the head and capacity that the system requires in the most efficient way.
Vertical turbine pumps can be multi-staged, allowing maximum flexibility both in the initial pump
selection and in the event that future system modifications require a change in the pump rating.
The submerged impellers allow the pump to be started without priming. The discharge head
changes the direction of flow from vertical to horizontal, and couples the pump to the system
piping, in addition to supporting and aligning the driver.
Drivers
A variety of drivers may be used; however, electric motors are most common. For the purposes
of this manual, all types of drivers can be grouped into two categories:
1. Hollow shaft drivers where the pump shaft extends through a tube in the center of the rotor and
is connected to the driver by a clutch assembly at the top of the driver.
2. Solid shaft drivers where the rotor shaft is solid and projects below the driver mounting base.
This type of driver requires an adjustable flanged coupling for connecting to the pump.
A shaft sealing arrangement is located in the discharge head to seal the shaft where it leaves the
liquid chamber. The shaft seal will usually be either a mechanical seal assembly or stuffing box.
Column Assembly
The shaft and column assembly provides a connection between the head and pump bowls. The
line shaft transfers the power from the motor to the impellers and the column carries the water to
the surface. The line shaft on a turbine pump may be either water lubricated or oil lubricated. The
oil-lubricated pump has an enclosed shaft into which oil drips, lubricating the bearings. The water-
lubricated pump has an open shaft. The bearings are lubricated by the pumped water.
101
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
If there is a possibility of fine sand being pumped, select the oil lubricated pump because it will
keep the sand out of the bearings. If the water is for domestic or livestock use, it must be free of
oil and a water-lubricated pump must be used.
Line shaft bearings are commonly placed on 10-foot centers for water-lubricated pumps operating
at speeds under 2,200 RPM and at 5-foot centers for pumps operating at higher speeds. Oil-
lubricated bearings are commonly placed on 5-foot centers.
A pump bowl encloses the impeller. Due to its limited diameter, each impeller develops a relatively
low head. In most deep well turbine installations, several bowls are stacked in series one above
the other. This is called staging. A four-stage bowl assembly contains four impellers; all attached
to a common shaft and will operate at four times the discharge head of a single-stage pump.
Impellers used in turbine pumps may be either semi-open or enclosed. The vanes on semi-open
impellers are open on the bottom and they rotate with a close tolerance to the bottom of the pump
bowl. The tolerance is critical and must be adjusted when the pump is new. During the initial
break-in period the line shaft couplings will tighten, therefore, after about 100 hours of operation,
the impeller adjustments should be checked. After break-in, the tolerance must be checked and
adjusted every three to five years or more often if pumping sand.
Bowl Assemblies
The bowl consists of:
1) impellers rigidly mounted on the bowl shaft, which rotate and impart energy to the fluid,
2) bowls to contain the increased pressure and direct the fluid,
3) suction bell or case which directs the fluid into the first impeller, and
4) bearings located in the suction bell (or case) and in each bowl.
Both types of impellers may cause inefficient pump operation if they are not properly adjusted.
Mechanical damage will result if the semi-open impellers are set too low and the vanes rub against
the bottom of the bowls. The adjustment of enclosed impellers is not as critical; however, they
must still be checked and adjusted.
Impeller adjustments are made by tightening or loosening a nut on the top of the head assembly.
Impeller adjustments are normally made by lowering the impellers to the bottom of the bowls and
adjusting them upward. The amount of upward adjustment is determined by how much the line
shaft will stretch during pumping. The adjustment must be made based on the lowest possible
pumping level in the well. The proper adjustment procedure if often provided by the pump
manufacturer.
102
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Basic Operation of a Vertical Turbine
Pre-start
Before starting the pump, the following checks should be made:
1. Rotate the pump shaft by hand to make sure the pump is free and the impellers are correctly
positioned.
2. Is the head shaft adjusting nut properly locked into position?
3. Has the driver been properly lubricated in accordance with the instructions furnished with the
driver?
4. Has the driver been checked for proper rotation? If not, the pump must be disconnected from
the driver before checking. The driver must rotate COUNTER CLOCKWISE when looking down
at the top of the driver.
5. Check all connections to the driver and control equipment.
6. Check that all piping connections are tight.
7. Check all anchor bolts for tightness.
8. Check all bolting and tubing connections for tightness (driver mounting bolts, flanged coupling
bolts, glad plate bolts, seal piping, etc.).
9. On pumps equipped with stuffing box, make sure the gland nuts are only finger tight DO
NOT TIGHTEN packing gland before starting.
10. On pumps equipped with mechanical seals, clean fluid should be put into the seal chamber.
With pumps under suction pressure this can be accomplished by bleeding all air and vapor out of
the seal chamber and allowing the fluid to enter. With pumps not under suction pressure, the seal
chamber should be flushed liberally with clean fluid to provide initial lubrication. Make sure the
mechanical seal is properly adjusted and locked
into place.
NOTE: After initial start-up, pre-lubrication of the mechanical seal will usually not be required, as
enough liquid will remain in the seal chamber for subsequent start-up lubrication.
11. On pumps equipped with enclosed lineshaft, lubricating liquid must be available and should
be allowed to run into the enclosing tube in sufficient quantity to thoroughly lubricate all lineshaft
bearings.
Initial Start-Up
1. If the discharge line has a valve in it, it should be partially open for initial starting Min. 10%.
2. Start lubrication liquid flow on enclosed lineshaft units.
3. Start the pump and observe the operation. If there is any difficulty, excess noise or vibration,
stop the pump immediately.
4. Open the discharge valve as desired.
5. Check complete pump and driver for leaks, loose connections, or improper operation.
6. If possible, the pump should be left running for approximately hour on the initial start-up. This
will allow the bearings, packing or seals, and other parts to run-in and reduce the possibility of
trouble on future starts.
NOTE: If abrasives or debris are present upon startup, the pump should be allowed to run until
the pumpage is clean. Stopping the pump when handling large amounts of abrasives (as
sometimes present on initial starting) may lock the pump and cause more damage than if the
pump is allowed to continue operation.
CAUTION: Every effort should be made to keep abrasives out of lines, sumps, etc. so that
abrasives will not enter the pump.
103
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Stuffing Box Adjustment
On the initial starting it is very important that the packing gland not be tightened too much. New
packing must be run in properly to prevent damage to the shaft and shortening of the packing
life. The stuffing box must be allowed to leak for proper operation. The proper amount of leakage
can be determined by checking the temperature of the leakage; this should be cool or just
lukewarm NOT HOT. When adjusting the packing gland, bring both nuts down evenly and in
small steps until the leakage is reduced as required. The nuts should only be tightened about
turn at a time at 20 to 30 minute intervals to allow the packing to run in. Under proper operation,
a set of packing will last a long time. Occasionally a new ring of packing will need to be added to
keep the box full. After adding two or three rings of packing, or when proper adjustment cannot
be achieved, the stuffing box should be cleaned completely of all old packing and re-packed.
Lineshaft Lubrication
Open lineshaft bearings are lubricated by the pumped fluid and on close coupled units (less than
30 long), will usually not require pre or post lubrication. Enclosed lineshaft bearings are lubricated
by extraneous liquid (usually oil or clean water), which is fed to the tension nut by either a gravity
flow system or pressure injection system. The gravity flow system utilizing oil is the most common
arrangement. The oil reservoir must be kept filled with a good quality light turbine oil (about 150
SSU at operating temperature) and adjusted to feed 10 to 12 drops per minute plus one (1) drop
per 100 of setting. Injection systems are designed for each installation injection pressure and
quantity of lubricating liquid will vary. Refer to packing slip or separate instruction sheet for
requirements when unit is designed for injection lubrication.
Deep well turbine pumps must have correct alignment between the pump and the power unit.
Correct alignment is made easy by using a head assembly that matches the motor and
column/pump assembly. It is very important that the well is straight and plumb. The pump column
assembly must be vertically aligned so that no part touches the well casing.
Spacers are usually attached to the pump column to prevent the pump assembly from touching
the well casing. If the pump column does touch the well casing, vibration will wear holes in the
casing. A pump column out of vertical alignment may also cause excessive bearing wear.
The head assembly must be mounted on a good foundation at least 12 inches above the ground
surface. A foundation of concrete (Figure 7) provides a permanent and trouble-free installation.
The foundation must be large enough to allow the head assembly to be securely fastened. The
foundation should have at least 12 inches of bearing surface on all sides of the well. In the case
of a gravel-packed well, the 12-inch clearance is measured from the outside edge of the gravel
packing.
104
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Vertical Turbine Pump
Larger check valve installed on submersible pump to prevent water hammer (notice motor
shaft splines.)
105
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Common Elements of Vertical Turbines
Below
Closed Pump Impeller
106
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Centrifugal Pump
By definition, a centrifugal pump is a machine. More specifically, it is a machine that imparts
energy to a fluid. This energy infusion can cause a liquid to flow, rise to a higher level, or both.
The centrifugal pump is an extremely simple machine. It is a member of a family known as rotary
machines and consists of two basic parts: 1) the rotary element or impeller and 2) the stationary
element or casing (volute). The figure at the bottom of the page is a cross section of a centrifugal
pump and shows the two basic parts.
In operation, a centrifugal pump slings liquid out of the impeller via centrifugal force. One fact
that must always be remembered: A pump does not create pressure, it only provides flow.
Pressure is just an indication of the amount of resistance to flow. Centrifugal pumps may be
classified in several ways. For example, they may be either SINGLE STAGE or MULTI-STAGE.
A single-stage pump has only one impeller. A multi-stage pump has two or more impellers housed
together in one casing.
As a rule, each impeller acts separately, discharging to the suction of the next stage impeller. This
arrangement is called series staging. Centrifugal pumps are also classified as HORIZONTAL or
VERTICAL, depending upon the position of the pump shaft. The impellers used on centrifugal
pumps may be classified as SINGLE SUCTION or DOUBLE SUCTION. The single-suction
impeller allows liquid to enter the eye from one side only. The double-suction impeller allows liquid
to enter the eye from two directions.
Impellers are also classified as CLOSED or OPEN. Closed impellers have side walls that extend
from the eye to the outer edge of the vane tips. Open impellers do not have these side walls.
Some small pumps with single-suction impellers have only a casing wearing ring and no impeller
ring. In this type of pump, the casing wearing ring is fitted into the end plate.
Recirculation lines are installed on some centrifugal pumps to prevent the pumps from
overheating and becoming vapor bound, in case the discharge is entirely shut off or the flow of
fluid is stopped for extended periods.
107
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Seal piping is installed to cool the shaft and the packing, to lubricate the packing, and to seal the
rotating joint between the shaft and the packing against air leakage. A lantern ring spacer is
inserted between the rings of the packing in the stuffing box.
Seal piping leads the liquid from the discharge side of the pump to the annular space formed by
the lantern ring. The web of the ring is perforated so that the water can flow in either direction
along the shaft (between the shaft and the packing).
Water flinger rings are fitted on the shaft between the packing gland and the pump bearing
housing. These flingers prevent water in the stuffing box from flowing along the shaft and entering
the bearing housing.
As the impeller rotates, it sucks the liquid into the center of the pump and throws it out under
pressure through the outlet. The casing that houses the impeller is referred to as the volute, the
impeller fits on the shaft inside. The volute has an inlet and outlet that carries the water as shown
above.
108
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
109
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
110
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
NPSH - Net Positive Suction Head
If you accept that a pump creates a partial vacuum and atmospheric pressure forces water into
the suction of the pump, then you will find NPSH a simple concept.
NPSH (a) is the Net Positive Suction Head Available, which is calculated as follows:
NPSH (a) = p + s - v - f
Where:
'p'= atmospheric pressure,
's'= static suction (If liquid is below pump, it is shown as a negative value)
'v'= liquid vapor pressure
'f'= friction loss
NPSH (a) must exceed NPSH(r) to allow pump operation without cavitation. (It is advisable to
allow approximately 1 meter difference for most installations.) The other important fact to
remember is that water will boil at much less than 100 degrees CO if the pressure acting on it is
less than its vapor pressure, i.e. water at 95 degrees C is just hot water at sea level, but at 1500m
above sea level it is boiling water and vapor.
The vapor pressure of water at 95 degrees C is 84.53 kPa, there was enough atmospheric
pressure at sea level to contain the vapor, but once the atmospheric pressure dropped at the
higher elevation, the vapor was able to escape. This is why vapor pressure is always considered
in NPSH calculations when temperatures exceed 30 to 40 degrees C.
NPSH(r) is the Net Positive Suction Head Required by the pump, which is read from the pump
performance curve. (Think of NPSH(r) as friction loss caused by the entry to the pump suction.)
Affinity Laws
The Centrifugal Pump is a very capable and flexible machine. Because of this it is unnecessary
to design a separate pump for each job. The performance of a centrifugal pump can be varied by
changing the impeller diameter or its rotational speed.
Either change produces approximately the same results. Reducing impeller diameter is probably
the most common change and is usually the most economical. The speed can be altered by
changing pulley diameters or by changing the speed of the driver. In some cases both speed and
impeller diameter are changed to obtain the desired results.
When the driven speed or impeller diameter of a centrifugal pump changes, operation of the
pump changes in accordance with three fundamental laws. These laws are known as the "Laws
of Affinity". They state that:
1) Capacity varies directly as the change in speed
2) Head varies as the square of the change in speed
3) Brake horsepower varies as the cube of the change in speed
If, for example, the pump speed were doubled:
1) Capacity will double
2) Head will increase by a factor of 4 (2 to the second power)
3) Brake horsepower will increase by a factor of 8 (2 to the third power)
111
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
These principles apply regardless of the direction (up or down) of the speed or change in
diameter.
Consider the following example. A pump operating at 1750 RPM, delivers 210 GPM at 75' TDH,
and requires 5.2 brake horsepower. What will happen if the speed is increased to 2000 RPM?
First we find the speed ratio.
Whether it be a speed change or change in impeller diameter, the Laws of Affinity give results
that are approximate. The discrepancy between the calculated values and the actual values
obtained in test are due to hydraulic efficiency changes that result from the modification. The
Laws of Affinity give reasonably close results when the changes are not more than 50% of the
original speed or 15% of the original diameter.
Suction conditions are some of the most important factors affecting centrifugal pump operation.
If they are ignored during the design or installation stages of an application, they will probably
come back to haunt you.
Suction Lift
A pump cannot pull or "suck" a liquid up its suction pipe because liquids do not exhibit tensile
strength. Therefore, they cannot transmit tension or be pulled. When a pump creates a suction, it
is simply reducing local pressure by creating a partial vacuum. Atmospheric or some other
external pressure acting on the surface of the liquid pushes the liquid up the suction pipe into the
pump. Atmospheric pressure at sea level is called absolute pressure (PSIA) because it is a
measurement using absolute zero (a perfect vacuum) as a base. If pressure is measured using
atmospheric pressure as a base it is called gauge pressure (PSIG or simply PSI).
Atmospheric pressure, as measured at sea level, is 14.7 PSIA. In feet of head it is:
Head = PSI X 2.31 / Specific Gravity
Thus, 34 feet is the theoretical maximum suction lift for a pump pumping cold water at sea level.
No pump can attain a suction lift of 34 ft; however, well designed ones can reach 25 ft quite easily.
You will note, from the equation above, that specific gravity can have a major effect on suction
lift. For example, the theoretical maximum lift for brine (Specific Gravity = 1.2) at sea level is 28
ft.. The realistic maximum is around 20ft. Remember to always factor in specific gravity if the liquid
being pumped is anything but clear, cold (68 degrees F) water.
112
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
In addition to pump design and suction piping, there are two physical properties of the liquid being
pumped that affect suction lift.
1) Maximum suction lift is dependent upon the pressure applied to the surface of the liquid at the
suction source. Maximum suction lift decreases as pressure decreases.
2) 2) Maximum suction lift is dependent upon the vapor pressure of the liquid being pumped. The
vapor pressure of a liquid is the pressure necessary to keep the liquid from vaporizing (boiling) at
a given temperature. Vapor pressure increases as liquid temperature increases. Maximum
suction lift decreases as vapor pressure rises.
It follows then, that the maximum suction lift of a centrifugal pump varies inversely with altitude.
Conversely, maximum suction lift will increase as the external pressure on its source increases
(for example: a closed pressure vessel).
Affinity laws
a. The flow changes proportionally to speed
i.e.: double the speed / double the flow
b. The pressure changes by the square of the difference
i.e.: double the speed / multiply the pressure by 4
c. The power changes by the cube of the difference
i.e.: double the speed / multiply the power by 8
Notes:
1. These laws apply to operating points at the same efficiency.
2. Variations in impeller diameter greater than 10% are hard to predict due to the change in
relationship between the impeller and the casing. For rough calculations you can adjust a duty
point or performance curve to suit a different speed. NPSH (r) is affected by speed / impeller
diameter change = DANGER!
113
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Casing
There are many variations of centrifugal pumps. The most common type is an end suction pump.
Another type of pump used is the split case. There are many variations of split case, such as;
two-stage, single suction, and double suction. Most of these pumps are horizontal.
There are variations of vertical centrifugal pumps. The line shaft turbine is really a multistage
centrifugal pump.
Impeller
In most centrifugal pumps, the impeller looks like a number of cupped vanes on blades mounted
on a disc or shaft. Notice in the picture below how the vanes of the impeller force the water into
the outlet of the pipe.
The shape of the vanes of the impeller is important. As the water is being thrown out of the pump,
this means you can run centrifugal pumps with the discharged valve closed for a SHORT period
of time. Remember the motor sends energy along the shaft, and if the water is in the volute too
long it will heat up and create steam. Not good!
The impellers all cause a flow from the eye of the impeller to the outside of the impeller. These
impellers cause what is called radial flow, and they can be referred to as radial flow impellers.
Axial flow impellers look like a propeller and create a flow that
is parallel to the shaft.
114
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Performance and Curves
Lets looks at the big picture. Before you make that purchase of the pump and motor you need
to know the basics such as:
115
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
116
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Motor and Pump Calculations
The centrifugal pump pumps the difference between the suction and the discharge heads. There
are three kinds of discharge head:
Static head. The height we are pumping to, or the height to the discharge piping outlet
that is filling the tank from the top. Note: that if you are filling the tank from the bottom, the
static head will be constantly changing.
Pressure head. If we are pumping to a pressurized vessel (like a boiler) we must convert
the pressure units (psi. or Kg.) to head units (feet or meters).
System or dynamic head. Caused by friction in the pipes, fittings, and system
components. We get this number by making the calculations from published charts.
Total Dynamic Head (TDH) is the total height that a fluid is to be pumped, taking into account
friction losses in the pipe.
where:
Static Lift is the height the water will rise before arriving at the pump (also known as the 'suction
head').
Static Height is the maximum height reached by the pipe after the pump (also known as the
'discharge head').
Friction Loss is the head equivalent to the energy losses due to viscose drag of fluid flowing in
the pipe (both on the suction and discharge sides of the pump). It is calculated via a formula or
a chart, taking into account the pipe diameter and roughness and the fluid flow rate, density,
and viscosity.
117
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Horsepower
Work involves the operation of force over a specific distance. The rate of doing work is called
power. The rate in which a horse could work was determined to be about 550 ft-lbs/sec or
33,000 ft-lbs/min.
1 hp = 33,000 ft-lbs/min
MHP refers to the horsepower supplied in the form of electrical current. The efficiency of most
motors range from 80-95%. (Manufactures will list efficiency %)
Water hp
Brake hp = ---------------
Pump Efficiency
BHP refers to the horsepower supplied to the pump from the motor. As the power moves
through the pump, additional horsepower is lost, resulting from slippage and friction of the shaft
and other factors.
Water Horsepower
The specific gravity of a liquid is an indication of its density or weight compared to water. The
difference in specific gravity, include it when calculating ft-lbs/min pumping requirements.
(ft)(lbs/min)(sp.gr.)
------------------------- = whp
33,000 ft-lbs/min/hp
118
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Well Calculations
1. Well drawdown
2. Well yield
Flow, gallons
Well yield, gpm = -----------------------
Duration of test, min
3. Specific yield
119
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Example 1
A centrifugal pump is located at an elevation of 722 ft. This pump is used to move water from
reservoir A to reservoir B. The water level in reservoir A is 742 ft and the water level in reservoir
B is 927 ft. Based on these conditions answer the following questions:
1. If the pump is not running and pressure gauges are installed on the suction and
discharge lines, what pressures would the gauges read?
Suction side:
Discharge side:
SSH:
SDH:
TSH:
6 psi:
48 psi:
110 psi:
20 ft:
205 ft:
185 ft:
120
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Motor, Coupling and Bearing Section
We will now refer to the motor, coupling, and bearings. The power source of the pump is usually
an electric motor. The motor is connected by a coupling to the pump shaft. The purpose of the
bearings is to hold the shaft firmly in place, yet allow it to rotate. The bearing house supports the
bearings and provides a reservoir for the lubricant. An impeller is connected to the shaft. The
pump assembly can be a vertical or horizontal set-up; the components for both are basically the
same.
Motors
The purpose of this discussion on pump motors is to identify and describe the main types of
motors, starters, enclosures and motor controls, as well as to provide you with some basic
maintenance and troubleshooting information. Although pumps could be driven by diesel or
gasoline engines, pumps driven by electric motors are commonly used in our industry.
D-C Motors
The important characteristic of the D-C motor is that its
speed will vary with the amount of current used. There
are many different kinds of D-C motors, depending on
how they are wound and their speed/torque
characteristics.
A-C Motors
There are a number of different types of alternating current motors, such as Synchronous,
Induction, wound rotor, and squirrel cage. The synchronous type of A-C motor requires complex
control equipment, since they use a combination of A-C and D-C. This also means that the
synchronous type of A-C motor is used in large horsepower sizes, usually above 250 HP. The
induction type motor uses only alternating current. The squirrel cage motor provides a relatively
constant speed. The wound rotor type could be used as a variable speed motor.
121
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Define the Following Terms:
Voltage:
EMF:
Power:
Current:
Resistance:
Conductor:
Phase:
Single Phase:
Three Phase:
Hertz:
Motor Starters
All electric motors, except very small ones such as chemical feed pumps, are equipped with
starters, either full voltage or reduced voltage. This is because motors draw a much higher current
when they are starting and gaining speed. The purpose of the reduced voltage starter is to prevent
the load from coming on until the amperage is low enough.
Motor Enclosures
Depending on the application, motors may need special
protection. Some motors are referred to as open motors.
They allow air to pass through to remove heat generated
when current passes through the windings. Other motors
use specific enclosures for special environments or safety
protection.
Can you think of any locations within your facility that requires special enclosures?
122
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Two Types of Totally Enclosed Motors Commonly Used are:
TENV, or totally enclosed non-ventilated motor
TEFC, or totally enclosed fan cooled motor
Totally enclosed motors include dust-proof, water-proof and explosion-proof motors. An explosion
proof enclosure must be provided on any motor where dangerous gases might accumulate.
Motor Controls
All pump motors are provided with some method of control, typically a combination of manual and
automatic. Manual pump controls can be located at the central control panel at the pump or at the
suction or discharge points of the liquid being pumped.
There are a number of ways in which automatic control of a pump motor can be regulated:
Pressure and vacuum sensors
Preset time intervals
Flow sensors
Level sensors
Motor Maintenance
Motors should be kept clean, free of
moisture, and lubricated properly. Dirt,
dust, and grime will plug the ventilating
spaces and can actually form an
insulating layer over the metal surface of
the motor.
123
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Moisture
Moisture harms the insulation on the windings to the point where they may no longer provide the
required insulation for the voltage applied to the motor. In addition, moisture on windings tend to
absorb acid and alkali fumes, causing damage to both insulation and metals. To reduce problems
caused by moisture, the most suitable motor enclosure for the existing environment will normally
be used. It is recommended to run stand by motors to dry up any condensation which accumulates
in the motor.
Motor Lubrication
Friction will cause wear in all moving parts, and lubrication is needed to reduce this friction. It is
very important that all your manufacturer's recommended lubrication procedures are strictly
followed. You have to be careful not to add too much grease or oil, as this could cause more
friction and generate heat.
1. Remove the protective plugs and caps from the grease inlet and relief holes.
2. Pump grease in until fresh starts coming from the relief hole.
If fresh grease does not come out of the relief hole, this could mean that the grease has been
pumped into the motor windings. The motor must then be taken apart and cleaned by a qualified
service representative.
To change the oil in an oil lubricated motor, this is the usual approach:
Never mix oils, since the additives of different oils when combined can cause breakdown of the
oil.
124
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
125
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
126
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Review Statements
The speed at which the magnetic field rotates is called the motors synchronous speed. It is
expressed in revolutions per minute. For a motor that operates on an electric power system
having a frequency of 60Hz, the maximum synchronous speed is 3,600 rpm, or 60 revolutions per
second. In other words, because the electric current changes its flow direction 60 times a second,
the rotor can rotate 60 times per second. This speed is achieved by a two-pole motor.
Backsiphonage is a condition in which the pressure in the distribution system is less than
atmospheric pressure. In other words, something is sucked into the system because the main
is under a vacuum.
When a pump operates under suction, the impeller inlet is actually operating in a vacuum. Air will
enter the water stream along the shaft if the packing does not provide an effective seal. It may
be impossible to tighten the packing sufficiently to prevent air from entering without causing
excessive heat and wear on the packing and shaft or shaft sleeve. To solve this problem, a
Lantern Ring can be placed in the Stuffing Box.
If the pump must operate under high suction head, the suction pressure itself will compress the
packing rings regardless of the operators care. Packing will then require frequent replacement.
Most manufactures recommend using mechanical seals for low-suction head conditions as well.
In general, any Centrifugal pump can be designed with a multistage configuration. Each stage
requires an additional Impeller and casing chamber in order to develop increased pressure, which
adds to the pressure developed by the preceding stage.
The axial-flow pump is often referred to as a Propeller Pump. In all centrifugal pumps, there must
be a flow restriction between the Impeller discharge and Suction areas that will prevent excessive
circulation of water between the two parts.
Altitude-Control Valve is designed to, 1. Prevent overflows from the storage tank or reservoir, or
2. Maintain a constant water level as long as water pressure in the distribution system is
adequate. Float mechanisms, diaphragm elements, bubbler tubes, and direct electronic sensors
are common types of level sensors.
The mechanical seal is designed so that it can be hydraulically balanced. The result is that the
wearing force between the machined surfaces does not vary regardless of the suction head. Most
seals have an operating life of 5,000 to 20,000 hours.
A chlorine demand test from a well water sample produces a result of 1.2 mg/L. The water
supplier would like to maintain a free chlorine residual of 0.2 mg/L throughout the system. The
chlorine dose should be 1.4 in mg/L from either a chlorinator or a hypochlorinator. The vacuum
created by a chlorine ejector moves through this device. Check valve assembly prevents water
from back feeding or entering the vacuum-regulator portion of the chlorinator.
A water storage facility should be able to provide water for the Fire and Peak demands. Surge
tanks are used to control Water Hammer. A couple of limitations of hydro-pneumatic tanks is; do
not provide much storage to meet peak demands during power outages and you have a small or
very limited time to do repairs on equipment.
127
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Peak demand is defined as the maximum momentary load placed on a water treatment plant,
pumping station or distribution system.
Concerning a single phase motor: If it is a split-phase motor, the motor will not have windings. A
repulsion-induction motor is very simple and less expensive than other single phase motors. On
most kilowatt meters, the current kilowatt load is indicated by Disk revolutions on the meter.
A foot valve is a check valve is located at the bottom end of the suction on a pump. This valve
opens when the pump operates to allow water to enter the suction pipe but closes when the pump
shuts off to prevent water from flowing out of the suction pipe.
Distribution system water quality can be adversely affected by improperly constructed or poorly
located blowoffs of vacuum/air relief valves. Air relief valves in the distribution system lines must
be placed in locations that cannot be flooded. This is to prevent water contamination. Milky water
is a common customer complaint is sometimes solved by the installation of air relief valves.
When the superintendent is inspecting the plans for a new ground water storage tank, the
superintendent should pay attention to the inlet and outlet of this tank. The outlet and inlet should
be on opposite sides of the tank.
Water quality in a storage facility could degrade due to excessive water age caused by low
demands for water and short-circuiting within the distribution storage reservoir. The following are
not other reasons for water quality degradation: Poor design, Inadequate maintenance and/or
Improperly applied coating and linings.
Older transmitting equipment requires installation where temperature will not exceed 130 F. A
diaphragm element being used as a level sensor would be used in conjunction with Pressure
Sensor. Inspection of magnetic flow meter instrumentation should include checking for corrosion
or insulation deterioration.
The most frequent problem that affects a liquid pressure-sensing device is air accumulation at the
sensor. The following are common pressure sensing devices: Helical Sensor, Bourdon Tube and
Bellows Sensor.
128
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Common Pump and Troubleshooting Questions
1. Cavitation: Cavitation is defined as the phenomenon of formation of vapor bubbles of a flowing
liquid in a region where the pressure of the liquid falls below its vapor pressure. One of the most
serious problems an operator will encounter is cavitation. It can be identified by a noise that
sounds like marbles or rocks are being pumped. The pump may also vibrate and shake, to the
point that piping is damaged, in some severe cases. Cavitation occurs when the pump starts
discharging water at a rate faster than it can be drawn into the pump. This situation is normally
caused by the loss of discharge head pressure or an obstruction in the suction line. When this
happens, a partial vacuum is created in the impeller causing the flow to become very erratic.
These vacuum-created cavities are formed on the backside of the impeller vanes. When cavitation
occurs, immediate action must be taken to prevent the impeller, pump and motor bearings, and
piping from being damaged. Cavitation can be temporarily corrected by throttling the discharge
valve. This action prevents damage to the pump until the cause can be found and corrected.
Remember that the discharge gate valve is there to isolate the pump, not control its flow. If it is
left in a throttled position the valve face may become worn to the point that it won't seal when the
pump must be isolated for maintenance. Butterfly valves can be throttled, but it is still not a good
idea to throttle a pump with an isolation valve.
2. What purpose do air and/or vacuum release valves serve on well casings?
Air and/or vacuum release valves are used to release trapped air or vacuums created in water
pipelines. This unique structure allows the dynamic valves to discharge air from the water system
in a controlled and gradual manner, preventing slam and local up-surges. When vacuum occurs,
the valves fast reaction will draw in large volumes of air into the water system, impeding down-
surges and, consequently, all pressure surges in the line. The valves are normally closed when
the line is not operating, thus preventing the infiltration of foreign particles and insects into the
water system.
4. What are the functions of a well casing and well casing perforations?
Well Casing is used to maintain an open access in the earth while not allowing any entrance or
leakage into the well from the surrounding formations. The most popular materials used for
casing are black steel, galvanized steel, PVC pipe and concrete pipe.
5. Well Casing Perforations: Is the process of creating holes in production casing to establish
communication between the well and formation. Perforation holes are used to recover water
from the ground.
7. How can ball bearing failure in a pump shaft bearing generally be first detected? Perform
vibration monitoring to detect failures or wait for excessive noise or heat. There are three types
of bearings commonly used: ball bearings, roller bearings, and sleeve bearings.
129
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Regardless of the particular type of bearings used within a system--whether it is ball bearings, a
sleeve bearing, or a roller bearing--the bearings are designed to carry the loads imposed on the
shaft. Bearings must be lubricated. Without proper lubrication, bearings will overheat and seize.
Proper lubrication means using the correct type and the correct amount of lubrication. Similar to
motor bearings, shaft bearings can be lubricated either by oil or by grease.
8. What is the purpose of the curved diffuser vanes on the inside of a pump volute?
Generation of Centrifugal Force: The process liquid enters the suction nozzle and then into eye
(center) of a revolving device known as an impeller. When the impeller rotates, it spins the liquid
sitting in the cavities between the vanes outward and provides centrifugal acceleration. As liquid
leaves the eye of the impeller a low-pressure area is created causing more liquid to flow toward
the inlet. Because the impeller blades are curved, the fluid is pushed in a tangential and radial
direction by the centrifugal force. This force acting inside the pump is the same one that keeps
water inside a bucket that is rotating at the end of a string.
9. What would be the advantage of starting and stopping a centrifugal pump against a
closed discharge valve? Keeping the prime in the pipe and not allowing air to fill the pump.
10. What precautions should be taken when opening and closing the discharge valve?
Turbulent flows caused by pump discharges, elbows and swedges upstream of a valve will also
cause the discs to flutter excessively. Be careful not to create a water hammer.
11. What effect could over-lubrication of grease-packed bearings have on a pump shaft?
Excessive friction and heat!
12. What are the three different designs of impellers in relation to shrouds that are used
on centrifugal pumps?
Semi-Closed also called Free passage (Vortex), Open and Closed.
Here is the proper way to vent a centrifugal pump after it has been initially installed, or the
system has been opened. Assuming the pump is empty of liquid and both the suction and
discharge valves are shut.
Open the suction valve. The pump fills part way.
Close the suction valve.
Open the discharge valve part way. Once the pressure equalizes the air will rise in the
discharge piping.
130
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Open the suction valve.
Start the pump.
When the pump hits its operating speed open the discharge valve to its proper setting to
operate close to the BEP. (Best efficiency point)
15. What factors would determine the size of well casing to use on a well?
Pump type, pump size and pumping depth. Well casings are installed in wells to prevent the
collapse of the walls of the borehole, to exclude pollutants (either surface or subsurface) from
entering the water source, and to provide a column of stored water to the well pump.
16. What is the main concern when using a coupling on a horizontal pump?
Proper alignment of the pump to the driver.
18. What are the two most common speeds of a centrifugal pump?
High speed (critical) and slower speed (variable).
19. What is a close-coupled pump and what purpose do the motor bearings serve?
Close-coupled pump has the motor and pump together without a shaft between the two. The
motor bearings will also support the impeller.
20. What should the operating pressure of seal water be in relation to the suction
pressure of a pump? An independent supply of water is needed for the seal water and its
pressure should be higher than the pumps suction.
23. Standpipe: A method of storing water and equalizing water pressure to minimize the
pulsations of water flowing in the mains, used prior to modern pumping methods, consisting of a
large vertical pipe in which a column of water rises and falls; often built inside towers.
24. What is water hammer, how is it caused, and how can it be prevented?
A large pressure surge that damages pipes and equipment. It is caused by rapid rising or falling
of water pressures or opening and shutting of valves. A hydropneumatic tank and careful
opening of valves can limit water hammer damage.
131
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
25. Hydropneumatic tank: A method of storing water prior to distribution in a water supply
system, whereby the water system pressure is maintained between a specified pressure range
and is also called pressure tanks.
132
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
More Detailed Information on Motors
The classic division of electric motors has been that of Direct Current (DC) types vs. Alternating
Current (AC) types. This is more a de facto convention, rather than a rigid distinction. For
example, many classic DC motors run happily on AC power.
The ongoing trend toward electronic control further muddles the distinction, as modern drivers
have moved the commutator out of the motor shell. For this new breed of motor, driver circuits
are relied upon to generate sinusoidal AC drive currents, or some approximation of. The two best
examples are: the brushless DC motor and the stepping motor, both being polyphase AC motors
requiring external electronic control.
There is a clearer distinction between a synchronous motor and asynchronous types. In the
synchronous types, the rotor rotates in synchrony with the oscillating field or current (e.g.
permanent magnet motors). In contrast, an asynchronous motor is designed to slip; the most
ubiquitous example being the common AC induction motor which must slip in order to generate
torque.
A DC motor is designed to run on DC electric power. Two examples of pure DC designs are
Michael Faraday's homopolar motor (which is uncommon), and the ball bearing motor, which is
(so far) a novelty. By far the most common DC motor types are the brushed and brushless types,
which use internal and external commutation respectively to create an oscillating AC current from
the DC source -- so they are not purely DC machines in a strict sense.
Brushed DC motors
The classic DC motor design generates an oscillating current in a wound rotor with a split ring
commutator, and either a wound or permanent magnet stator. A rotor consists of a coil wound
around a rotor which is then powered by any type of battery. Many of the limitations of the classic
commutator DC motor are due to the need for brushes to press against the commutator. This
creates friction. At higher speeds, brushes have increasing difficulty in maintaining contact.
Brushes may bounce off the irregularities in the commutator surface, creating sparks. This limits
the maximum speed of the machine.
133
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The current density per unit area of the brushes limits the output of the motor. The imperfect
electric contact also causes electrical noise. Brushes eventually wear out and require
replacement, and the commutator itself is subject to wear and maintenance. The commutator
assembly on a large machine is a costly element, requiring precision assembly of many parts.
Brushless DC Motors
Some of the problems of the brushed DC motor are eliminated in the brushless design. In this
motor, the mechanical "rotating switch" or commutator/brush gear assembly is replaced by an
external electronic switch synchronized to the rotor's position. Brushless motors are typically 85-
90% efficient, whereas DC motors with brush gear are typically 75-80% efficient.
Midway between ordinary DC motors and stepper motors lies the realm of the brushless DC
motor. Built in a fashion very similar to stepper motors, these often use a permanent magnet
external rotor, three phases of driving coils, one or more Hall Effect sensors to sense the position
of the rotor, and the associated drive electronics.
134
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The coils are activated one phase after the other by the drive electronics, as cued by the signals
from the Hall effect sensors. In effect, they act as three-phase synchronous motors containing
their own variable-frequency drive electronics. Brushless DC motors are commonly used where
precise speed control is necessary, as in computer disk drives or in video cassette recorders, the
spindles within CD, CD-ROM (etc.) drives, and mechanisms within office products such as fans,
laser printers, and photocopiers.
Modern DC brushless motors range in power from a fraction of a watt to many kilowatts. Larger
brushless motors up to about 100 kW rating are used in electric vehicles. They also find significant
use in high-performance electric model aircraft.
Coreless DC Motors
Nothing in the design of any of the motors described above requires that the iron (steel) portions
of the rotor actually rotate; torque is exerted only on the windings of the electromagnets. Taking
advantage of this fact is the coreless DC motor, a specialized form of a brush or brushless DC
motor. Optimized for rapid acceleration, these motors have a rotor that is constructed without any
iron core. The rotor can take the form of a winding-filled cylinder inside the stator magnets, a
basket surrounding the stator magnets, or a flat pancake (possibly formed on a printed wiring
board) running between upper and lower stator magnets. The windings are typically stabilized by
being impregnated with electrical epoxy potting systems. Filled epoxies that have moderate mixed
viscosity and a long gel time. These systems are highlighted by low shrinkage and low exotherm.
Because the rotor is much lighter in weight (mass) than a conventional rotor formed from copper
windings on steel laminations, the rotor can accelerate much more rapidly, often achieving a
mechanical time constant under 1 ms. This is especially true if the windings use aluminum rather
than the heavier copper. But because there is no metal mass in the rotor to act as a heat sink,
even small coreless motors must often be cooled by forced air.
These motors were commonly used to drive the capstan(s) of magnetic tape drives and are still
widely used in high-performance servo-controlled systems, like radio-controlled vehicles/aircraft,
humanoid robotic systems, industrial automation, medical devices, etc.
135
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Universal Motors
A variant of the wound field DC motor is the universal motor. The name derives from the fact that
it may use AC or DC supply current, although in practice they are nearly always used with AC
supplies. The principle is that in a wound field DC motor the current in both the field and the
armature (and hence the resultant magnetic fields) will alternate (reverse polarity) at the same
time, and hence the mechanical force generated is always in the same direction. In practice, the
motor must be specially designed to cope with the AC current (impedance must be taken into
account, as must the pulsating force), and the resultant motor is generally less efficient than an
equivalent pure DC motor.
Operating at normal power line frequencies, the maximum output of universal motors is limited
and motors exceeding one kilowatt are rare. But universal motors also form the basis of the
traditional railway traction motor in electric railways. In this application, to keep their electrical
efficiency high, they were operated from very low frequency AC supplies, with 25 Hz and 16 2/3
hertz operation being common. Because they are universal motors, locomotives using this design
were also commonly capable of operating from a third rail powered by DC.
The advantage of the universal motor is that AC supplies may be used on motors which have the
typical characteristics of DC motors, specifically high starting torque and very compact design if
high running speeds are used. The negative aspect is the maintenance and short life problems
caused by the commutator. As a result, such motors are usually used in AC devices such as food
mixers and power tools which are used only intermittently.
Continuous speed control of a universal motor running on AC is very easily accomplished using
a thyristor circuit, while stepped speed control can be accomplished using multiple taps on the
field coil. Household blenders that advertise many speeds frequently combine a field coil with
several taps and a diode that can be inserted in series with the motor (causing the motor to run
on half-wave rectified AC).
136
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
AC Motors
In 1882, Nicola Tesla identified the rotating magnetic field principle, and pioneered the use of a
rotary field of force to operate machines. He exploited the principle to design a unique two-phase
induction motor in 1883. In 1885, Galileo Ferraris independently researched the concept. In 1888,
Ferraris published his research in a paper to the Royal Academy of Sciences in Turin.
Introduction of Tesla's motor from 1888 onwards initiated what is sometimes referred to as the
Second Industrial Revolution, making possible the efficient generation and long distance
distribution of electrical energy using the alternating current transmission system, also of Tesla's
invention (1888). Before the invention of the rotating magnetic field, motors operated by
continually passing a conductor through a stationary magnetic field (as in homopolar motors).
Tesla had suggested that the commutators from a machine could be removed and the device
could operate on a rotary field of force. Professor Poeschel, his teacher, stated that would be akin
to building a perpetual motion machine.
Components
A typical AC motor consists of two parts:
1. An outside stationary stator having coils supplied with AC current to produce a rotating
magnetic field, and;
2. An inside rotor attached to the output shaft that is given a torque by the rotating field.
Torque motors
A torque motor is a specialized form of induction motor which is capable of operating indefinitely
at stall (with the rotor blocked from turning) without damage. In this mode, the motor will apply a
steady stall torque to the load (hence the name). A common application of a torque motor would
be the supply- and take-up reel motors in a tape drive. In this application, driven from a low
voltage, the characteristics of these motors allow a relatively-constant light tension to be applied
to the tape whether or not the capstan is feeding tape past the tape heads.
Driven from a higher voltage, (and so delivering a higher torque), the torque motors can also
achieve fast-forward and rewind operation without requiring any additional mechanics such as
gears or clutches. In the computer world, torque motors are used with force feedback steering
wheels.
Slip Ring
The slip ring or wound rotor motor is an induction machine where the rotor comprises a set of
coils that are terminated in slip rings to which external impedances can be connected. The stator
is the same as is used with a standard squirrel cage motor. By changing the impedance connected
to the rotor circuit, the speed/current and speed/torque curves can be altered.
The slip ring motor is used primarily to start a high inertia load or a load that requires a very high
starting torque across the full speed range. By correctly selecting the resistors used in the
secondary resistance or slip ring starter, the motor is able to produce maximum torque at a
relatively low current from zero speed to full speed. A secondary use of the slip ring motor is to
provide a means of speed control.
Because the torque curve of the motor is effectively modified by the resistance connected to the
rotor circuit, the speed of the motor can be altered. Increasing the value of resistance on the rotor
circuit will move the speed of maximum torque down.
137
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
If the resistance connected to the rotor is increased beyond the point where the maximum torque
occurs at zero speed, the torque will be further reduced. When used with a load that has a torque
curve that increases with speed, the motor will operate at the speed where the torque developed
by the motor is equal to the load torque.
Reducing the load will cause the motor to speed up, and increasing the load will cause the motor
to slow down until the load and motor torque are equal. Operated in this manner, the slip losses
are dissipated in the secondary resistors and can be very significant. The speed regulation is also
very poor.
Stepper Motors
Closely related in design to three-phase AC synchronous motors are stepper motors, where an
internal rotor containing permanent magnets or a large iron core with salient poles is controlled
by a set of external magnets that are switched electronically.
A stepper motor may also be thought of as a cross between a DC electric motor and a solenoid.
As each coil is energized in turn, the rotor aligns itself with the magnetic field produced by the
energized field winding. Unlike a synchronous motor, in its application, the motor may not rotate
continuously; instead, it "steps" from one position to the next as field windings are energized and
de-energized in sequence. Depending on the sequence, the rotor may turn forwards or
backwards.
Simple stepper motor drivers entirely energize or entirely de-energize the field windings, leading
the rotor to "cog" to a limited number of positions; more sophisticated drivers can proportionally
control the power to the field windings, allowing the rotors to position between the cog points and
thereby rotate extremely smoothly. Computer controlled stepper motors are one of the most
versatile forms of positioning systems, particularly when part of a digital servo-controlled system.
Stepper motors can be rotated to a specific angle with ease, and hence stepper motors are used
in pre-gigabyte era computer disk drives, where the precision they offered was adequate for the
correct positioning of the read/write head of a hard disk drive. As drive density increased, the
precision limitations of stepper motors made them obsolete for hard drives, thus newer hard disk
drives use read/write head control systems based on voice coils. Stepper motors were upscaled
to be used in electric vehicles under the term SRM (switched reluctance machine).
138
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Coupling Section
The pump coupling serves two main purposes:
It couples or joins the two shafts together to transfer the rotation from motor to impeller.
It compensates for small amounts of misalignment between the pump and the motor.
Remember that any coupling is a device in motion. If you have a 4-inch diameter coupling rotating
at 1800 rpm, its outer surface is traveling about 20 mph. With that in mind, can you think of safety
considerations?
There are three commonly used types of couplings: Rigid, Flexible and V-belts.
Rigid Coupling
Rigid couplings are most commonly used on vertically mounted pumps. The rigid coupling is
usually specially keyed or constructed for joining the coupling to the motor shaft and the pump
shaft. There are two types of rigid couplings: the flanged coupling, and the split coupling.
Flexible Coupling
The flexible coupling provides the ability to compensate for small shaft misalignments. Shafts
should be aligned as close as possible, regardless. The greater the misalignment, the shorter the
life of the coupling. Bearing wear and life are also affected by misalignment.
139
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Alignment of Flexible and Rigid Couplings
Both flexible and rigid couplings must be carefully aligned before they are connected.
Misalignment will cause excessive heat and vibration, as well as bearing wear. Usually, the
noise from the coupling will warn you of shaft misalignment problems.
Three types of shaft alignment problems are shown in the pictures below:
Different couplings will require different alignment procedures. We will look at the general
procedures for aligning shafts.
Now you can check the units for both parallel and angular alignment. Many techniques are used,
such as: straight edge, needle deflection (dial indicators), calipers, tapered wedges, and laser
alignment.
Shaft Bearings
There are three types of bearings commonly used: ball bearings, roller bearings, and sleeve
bearings. Regardless of the particular type of bearings used within a system--whether it is ball
bearings, a sleeve bearing, or a roller bearing--the bearings are designed to carry the loads
imposed on the shaft.
Bearings must be lubricated. Without proper lubrication, bearings will overheat and seize.
Proper lubrication means using the correct type and the correct amount of lubrication. Similar to
motor bearings, shaft bearings can be lubricated either by oil or by grease.
140
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Packing Seals
Should packing have leakage?
How can we prevent the water from leaking along the shaft?
A special seal is used to prevent liquid leaking out along the shaft. There are two types of seals
commonly used:
Packing seal
Mechanical seal
Leakage
During pump operation, a certain amount of
leakage around the shafts and casings
normally takes place.
The amount of leakage that can occur without limiting pump efficiency determines the type of
shaft sealing selected. Shaft sealing systems are found in every pump. They can vary from simple
packing to complicated sealing systems.
Packing is the most common and oldest method of sealing. Leakage is checked by the
compression of packing rings that causes the rings to deform and seal around the pump shaft
and casing. The packing is lubricated by liquid moving through a lantern ring in the center of the
packing. The sealing slows down the rate of leakage. It does not stop it completely, since a certain
amount of leakage is necessary during operation. Mechanical seals are rapidly replacing
conventional packing on centrifugal pumps.
Some of the reasons for the use of mechanical seals are as follows:
1. Leaking causes bearing failure by contaminating the oil with water. This is a major problem in
engine-mounted water pumps.
2. Properly installed mechanical seals eliminate leakoff on idle (vertical) pumps. This design
prevents the leak (water) from bypassing the water flinger and entering the lower bearings.
Leakoff causes two types of seal leakage:
a. Water contamination of the engine lubrication oil.
b. Loss of treated fresh water that causes scale buildup in the cooling system.
Centrifugal pumps are versatile and have many uses. This type of pump is commonly used to
pump all types of water and wastewater flows, including thin sludge.
141
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Lantern Rings
Lantern rings are used to supply clean water along the shaft. This helps to prevent grit and air
from reaching the area. Another component is the slinger ring. The slinger ring is an important
part of the pump because it is used to protect the bearings. Other materials can be used to prevent
this burier.
Mechanical Seals
Mechanical seals are commonly used to reduce leakage
around the pump shaft. There are many types of mechanical
seals. The photograph below illustrates the basic
components of a mechanical seal. Similar to the packing
seal, clean water is fed at a pressure greater than that of the
liquid being pumped. There is little or no leakage through the
mechanical seal. The wearing surface must be kept
extremely clean. Even fingerprints on the wearing surface
can introduce enough dirt to cause problems.
Mechanical Seals
Wear Rings
Not all pumps have wear rings. However, when they are included, they are usually replaceable.
Wear rings can be located on the suctions side and head side of the volute. Wear rings could be
made of the same metal but of different alloys. The wear ring on the head side is usually a harder
alloy.
142
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Mechanical Seals
Mechanical seals are rapidly replacing
conventional packing as the means of
controlling leakage on rotary and positive-
displacement pumps.
You should replace a mechanical seal whenever the seal is removed from the shaft for any
reason, or whenever leakage causes undesirable effects on equipment or surrounding spaces.
Do not touch a new seal on the sealing face because body acid and grease or dirt will cause the
seal to pit prematurely and leak.
Mechanical shaft seals are positioned on the shaft by stub or step sleeves. Mechanical shaft seals
must not be positioned by setscrews. Shaft sleeves are chamfered (beveled) on the outboard
ends for easy mechanical seal mounting.
Mechanical shaft seals serve to ensure that position liquid pressure is supplied to the seal faces
under all conditions of operation. They also ensure adequate circulation of the liquid at the seal
faces to minimize the deposit of foreign matter on the seal parts.
143
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
144
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Troubleshooting Section
Some of the operating problems you may encounter with centrifugal pumps as an Operator,
together with the probable causes, are discussed in the following paragraphs.
If a centrifugal pump DOES NOT DELIVER ANY LIQUID, the trouble may be caused by (1)
insufficient priming; (2) insufficient speed of the pump; (3) excessive discharge pressure, such as
might be caused by a partially closed valve or some other obstruction in the discharge line; (4)
excessive suction lift; (5) clogged impeller passages; (6) the wrong direction of rotation (this may
occur after motor overhaul); (7) clogged suction screen (if used); (8) ruptured suction line; or (9)
loss of suction pressure.
If a centrifugal pump delivers some liquid but operates at INSUFFICIENT CAPACITY, the trouble
may be caused by (1) air leakage into the suction line; (2) air leakage into the stuffing boxes in
pumps operating at less than atmospheric pressure; (3) insufficient pump speed; (4) excessive
suction lift; (5) insufficient liquid on the suction side; (6) clogged impeller passages; (7) excessive
discharge pressure; or (8) mechanical defects, such as worn wearing rings, impellers, stuffing box
packing, or sleeves.
If a pump DOES NOT DEVELOP DESIGN DISCHARGE PRESSURE, the trouble may be caused
by (1) insufficient pump speed; (2) air or gas in the liquid being pumped; (3) mechanical defects,
such as worn wearing rings, impellers, stuffing box packing, or sleeves; or (4) reversed rotation
of the impeller (3-phase electric motor-driven pumps). If a pump WORKS FOR A WHILE AND
THEN FAILS TO DELIVER LIQUID, the trouble may be caused by (1) air leakage into the suction
line; (2) air leakage in the stuffing boxes; (3) clogged water seal passages; (4) insufficient liquid
on the suction side; or (5) excessive heat in the liquid being pumped.
If a motor-driven centrifugal pump DRAWS TOO MUCH POWER, the trouble will probably be
indicated by overheating of the motor. The basic causes may be (1) operation of the pump to
excess capacity and insufficient discharge pressure; (2) too high viscosity or specific gravity of
the liquid being pumped; or (3) misalignment, a bent shaft, excessively tight stuffing box packing,
worn wearing rings, or other mechanical defects.
VIBRATION of a centrifugal pump is often caused by (1) misalignment; (2) a bent shaft; (3) a
clogged, eroded, or otherwise unbalanced impeller; or (4) lack of rigidity in the foundation.
Insufficient suction pressure may also cause vibration, as well as noisy operation and fluctuating
discharge pressure, particularly in pumps that handle hot or volatile liquids. If the pump fails to
build up pressure when the discharge valve is opened and the pump comes up to normal
operating speed, proceed as follows:
1. Shut the pump discharge valve.
2. Secure the pump.
3. Open all valves in the pump suction line.
4. Prime the pump (fill casing with the liquid being pumped) and be sure that all air is expelled
through the air cocks on the pump casing.
5. Restart the pump. If the pump is electrically driven, be sure the pump is rotating in the correct
direction.
6. Open the discharge valve to load the pump. If the discharge pressure is not normal when the
pump is up to its proper speed, the suction line may be clogged, or an impeller may be broken. It
is also possible that air is being drawn into the suction line or into the casing. If any of these
conditions exist, stop the pump and continue troubleshooting according to the technical manual
for that unit.
145
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Finger is shown pointing to a Lantern Ring. This old school method of sealing a pump is
still out there. Notice the packing on both sides of the ring. The packing joints need to
be staggered and the purpose of this device is to allow air to the Stuffing Box.
146
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Maintenance of Centrifugal Pumps
When properly installed, maintained and operated, centrifugal pumps are usually trouble-free.
Some of the most common corrective maintenance actions that you may be required to perform
are discussed in the following sections.
Next, start the pump. Let it operate for about 30 minutes before you adjust the packing gland for
the desired amount of leak-off. This gives the packing time to run-in and swell. You may then
begin to adjust the packing gland.
Tighten the adjusting nuts one flat at a time. Wait about 30 minutes between adjustments. Be
sure to tighten the same amount on both adjusting nuts. If you pull up the packing gland unevenly
(or cocked), it will cause the packing to overheat and score the shaft sleeves. Once you have the
desired leak-off, check it regularly to make certain that sufficient flow is maintained.
Mechanical Seals
Mechanical seals are rapidly replacing conventional packing as the means of controlling leakage
on rotary and positive-displacement pumps. Mechanical seals eliminate the problem of excessive
stuffing box leakage, which causes failure of pump and motor bearings and motor windings.
Mechanical seals are ideal for pumps that operate in closed systems (such as fuel service and
air-conditioning, chilled-water, and various cooling systems). They not only conserve the fluid
being pumped, but also improve system operation. The type of material used for the seal faces
will depend upon the service of the pump. Most water service pumps use a carbon material for
one of the seal faces and ceramic (tungsten carbide) for the other. When the seals wear out, they
are simply replaced.
147
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
You should replace a mechanical seal whenever the seal is removed from the shaft for any
reason, or whenever leakage causes undesirable effects on equipment or surrounding spaces.
Do not touch a new seal on the sealing face because body acid and grease or dirt will cause the
seal to pit prematurely and leak.
Mechanical shaft seals are positioned on the shaft by stub or step sleeves. Mechanical shaft seals
must not be positioned by setscrews. Shaft sleeves are chamfered (beveled) on outboard ends
for easy mechanical seal mounting.
Mechanical shaft seals serve to ensure that liquid pressure is supplied to the seal faces under all
conditions of operation. They also ensure adequate circulation of the liquid at the seal faces to
minimize the deposit of foreign matter on the seal parts.
148
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Troubleshooting Table for Well/Pump Problems
1. Well pump will not start.
2. Well pump will not shut off.
3. Well pump starts and stops too frequently (excessive cycle rate).
4. Sand sediment is present in the water.
5. Well pump operates with reduced flow.
6. Well house flooded without recent precipitation.
7. Red or black water complaints.
8. Raw water appears turbid or a light tan color following rainfall.
9. Coliform tests are positive.
Possible Causes
1A. Circuit breaker or overload relay tripped.
1B. Fuse(s) burned out.
1C. No power to switch box.
1D. Short, broken or loose wire.
1E. Low voltage.
1F. Defective motor.
1G. Defective pressure switch.
2A. Defective pressure switch.
2B. Cut-off pressure setting too high.
2C. Float switch or pressure transducer not
functioning.
3A. Pressure switch settings too close.
3B. Pump foot valve leaking.
3C. Water-logged hydropneumatic tank.
4A. Problems with well screen or gravel envelope.
5A. Valve on discharge partially closed or line clogged.
5B. Well is over-pumped.
5C. Well screen clogged.
6A. Check valve not operating properly.
6B. Leakage occurring in discharge piping or valves.
7A. Water contains excessive iron (red brown) and/or manganese (black water).
7B. Complainants hot water needs maintenance.
8A. Surface water entering or influencing well.
9A. Sample is invalid.
9B. Sanitary protection of well has been breached.
Possible Solutions
1A. Reset breaker or manual overload relay.
1B. Check for cause and correct, replace fuse(s).
1C. Check incoming power supply. Contact power company.
1D. Check for shorts and correct, tighten terminals, replace broken wires.
1E. Check incoming line voltage. Contact power company if low.
1F. Contact electrical contractor.
1G. Check voltage of incoming electric supply with pressure switch closed. Contact power
company if voltage low. Perform maintenance on switch if voltage normal.
2A. Check switch for proper operation. Replace switch.
2B. Adjust setting.
2C. Check and replace components or cable as needed.
149
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
3A. Adjust settings.
3B. Check for backflow. Contact well contractor.
3C. Check air volume. Add air if needed. If persistent, check air compressor, relief valve, air
lines and connections, and repair if needed.
4A. Contact well contractor.
5A. Open valve, unclog discharge line.
5B. Check static water level and compare to past readings. If significantly lower, notify well
contractor.
5C. Contact well contractor.
6A. Repair or replace check valve.
6B. Inspect and repair/replace as necessary.
7A. Test for iron and manganese at well. If levels exceed 0.3 mg/L iron or 0.005mg/L
manganese, contact regulatory agency, TA provider or water treatment contractor.
7B. Check hot water heater and flush if needed.
8A. Check well for openings that allow surface water to enter. Check area for sinkholes,
fractures, or other physical evidence of surface water intrusion. Check water turbidity. Notify
regulatory agency if >0.5 NTU. Check raw water for coliform bacteria. Notify regulatory agency
immediately if positive.
9A. Check sampling technique, sampling container, and sampling location and tap.
9B. Notify regulatory agency immediately and re-sample for re-testing.
This brush is used to dislodge debris inside well casing. Just a big toilet cleaning brush.
150
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
SCADA
What is SCADA?
SCADA stands for Supervisory Control and Data Acquisition. As the name indicates, it is not a
full control system, but rather focuses on the supervisory level. As such, it is a purely software
package that is positioned on top of hardware to which it is interfaced, in general via
Programmable Logic Controllers (PLCs), or other commercial hardware modules. Contemporary
SCADA systems exhibit predominantly open-loop control characteristics and utilize predominantly
long distance communications, although some elements of closed-loop control and/or short
distance communications may also be present. Systems similar to SCADA systems are routinely
seen in treatment plants and distribution systems. These are often referred to as Distributed
Control Systems (DCS). They have similar functions to SCADA systems, but the field data
gathering or control units are usually located within a more confined area. Communications may
be via a local area network (LAN), and will normally be reliable and high speed. A DCS system
usually employs significant amounts of closed loop control.
The data is processed to detect alarm conditions, and if an alarm is present, it will be displayed
on special alarm lists. Data can be of three main types. Analogue data (i.e. real numbers) will be
trended (i.e. placed in graphs). Digital data (on/off) may
have alarms attached to one state or the other. Pulse
data (e.g. counting revolutions of a meter) is normally
accumulated or counted.
151
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
152
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Electrical Glossary
ALTERNATING CURRENT (AC) - A current which reverses in regularly recurring intervals of
time and which has alternative positive and negative values, and occurring a specified number
of times per second. The number is expressed in cycles per second or Hertz (Hz).
ALARM LIGHT - A light which is used to attract attention when a problem occurs in the system.
ALTERNATOR - A relay device designed for alternating the run cycle or duplexing action of two
or more motors automatically. There are two basic types; one mechanically changes its contacts
each time the operating coil is de-energized, and the second is a solid state unit with an output
relay. The alternator is used in the automatic control circuit to the motor starters to rotate the
duty cycle of each motor.
AMBIENT TEMPERATURE - Temperature of the surroundings in which the equipment is used
or operated.
AMMETER - Meter for measuring the current in an electrical circuit, measured in amperes.
AMPERE - The unit of electric current flow. One ampere will flow when one volt is applied
across a resistance of one ohm.
AUDIBLE ALARM - Horn, siren, bell, or buzzer which is used to attract the attention of the
operator when a problem occurs in the system.
AUXILIARY CONTACTS - Contacts of a switching device in addition to the main current
contacts that operate with the movement of the latter. They can be normally open (NO) or
normally closed (NC) and change state when operated.
CAPACITOR - A device which introduces capacitance into an electrical circuit. The capacitor,
when connected in an alternating current circuit, causes the current to lead the voltage in time
phase. The peak of the current wave is reached ahead of the peak of the voltage wave. This is
the result of the successive storage and discharge of electric energy.
CIRCUIT BREAKER - A mechanical switching device capable of making, carrying, and
breaking currents under normal conditions. Also making, carrying for a specific time, and
automatically breaking currents under specified abnormal circuit conditions, such as those of
short circuit. Circuit breakers have an ampere trip rating for normal overload protection and a
maximum magnetic ampere interrupting capacity (AIC) for short circuit protection.
COMMERCIAL POWER - The power furnished by an electric power utility.
CONDENSATION HEATER - A device that warms the air within an enclosure and prevents
condensation of moisture during shut-down periods. Also known as a space heater.
CONDUCTOR - A wire, cable or bus bar designed for the passage of electrical current.
CONTACTOR - An electro-mechanical device that is operated by an electric coil and allows
automatic or remote operation to repeatedly establish or interrupt an electrical power circuit. A
contactor provides no overload protection as required for motor loads. Sometimes called a
power relay.
CONTACTS - Devices for making and breaking electrical circuits, which are a part of all
electrical switching devices.
CURRENT - The amount of electricity measured in amperes which is flowing in a circuit.
CYCLE - A given length of time (See Alternating Current). In the U.S., most electric current is 60
cycle (60 Hz).
CYCLE TIMER - A timer that repeatedly opens and closes contacts according to pre-set time
cycles.
DELTA CONNECTION - A common three phase connection shaped schematically like the
Greek Delta. The end of one phase is connected to the beginning of the next phase, or vice
versa.
153
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
DESIGN LETTER - A letter that is shown on the motor nameplate indicating NEMA's
classification of that motor. Classification encompasses characteristics such as full-voltage
starting, locked rotor torque, breakdown torque, and others that determine electrical type.
DISCONNECTING MEANS (DISCONNECT) - A device or group of devices, or other means
whereby all the ungrounded conductors of a circuit can be disconnected simultaneously from
their source of supply.
ELAPSED TIME METER - An instrument used to record the amount of time each pump runs.
One elapsed time meter is used per pump.
ELECTRIC UTILITIES - All enterprises engaged in the production and/or distribution of
electricity for use by the public.
EMERGENCY POWER (ALTERNATE SOURCE OF POWER) - An independent reserve
source of electric power which, upon failure or outage of the normal power source, provides
stand-by electric power.
ENCLOSURE - The cabinet or specially designed box in which electrical controls and apparatus
are housed. It is required by the National Electrical Code (NEC) to protect persons from live
electrical parts and limit access to authorized personnel. It also provides mechanical and
environmental protection. An enclosure should be designed to provide the required protection
and sized to provide good, safe wire access and replacement of components. It can be
manufactured of steel, galvanized or stainless steel, aluminum, or suitable non-metallic
materials including fiberglass.
EXPLOSION-PROOF MOTOR - A motor in a special enclosure. The purpose of the enclosure
is twofold:
1) If an explosive vapor (gas) should explode inside the motor, the frame of the motor
will not be affected.
2) The enclosure is so constructed that no such explosion will ignite vapors outside the
motor.
FACTORY MUTUAL (FM) - Independent U.S. agency associated with the insurance industry
which tests for safety.
FREQUENCY - The number of complete cycles of an alternating voltage or current per unit of
time and usually expressed in cycles per second or Hertz (Hz).
FULL LOAD CURRENT - The greatest current that a motor or other device is designed to carry
under specific conditions; any additional is an overload.
FULL LOAD AMPS (FULL LOAD CURRENT) - The current flowing through a line terminal of a
winding when rated voltage is applied at rated frequency with rated horsepower.
FUSE - An over-current protective device which consists of a conductor that melts and breaks
when current exceeds rated value beyond a predetermined time.
GENERAL PURPOSE RELAY - A relay that is adaptable to a wide variety of applications as
opposed to a relay designed for a specific purpose or specific application.
GENERATOR - A machine for converting mechanical energy into electrical energy or power.
GENERATOR RECEPTACLE - A contact device installed for the connection of a plug and
flexible cord to supply emergency power from a portable generator or other alternate source of
power. Receptacles are rated in voltage, amps, number of wires, and by enclosure type.
GROUND - A connection, either intentional or accidental, between an electric circuit and the
earth or some conducting body serving in place of the earth.
GROUND FAULT INTERRUPTION (GFI) - A unit or combination of units which provides
protection against ground fault currents below the trip levels of the breakers of a circuit. The
system must be carefully designed and installed to sense low magnitude insulation breakdowns
and other faults that cause a fault ground current path. The GFI system must be capable of
sensing the ground fault current and disconnecting the faulted circuit from the source voltage.
154
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
GROUNDED NEUTRAL - The common neutral conductor of an electrical system which is
intentionally connected to ground to provide a current carrying path for the line to neutral load
devices.
GROUNDING CONDUCTOR - The conductor that is used to establish a ground and that
connects equipment, a device, a wiring system, or another conductor (usually the neutral
conductor) with the grounding electrode.
HAND-OFF-AUTOMATIC (HOA) - Selector switch determining the mode of system operation.
H is the hand mode only. 0 is system Off. A is automatic operation, normally with pump
alternation.
HAZARDOUS LOCATIONS - Those areas as defined in the NEC where a potential for
explosion and fire exist because of flammable gasses, vapors, or finely pulverized dusts in the
atmosphere, or because of the presence of easily ignitable fibers or flyings.
HERTZ (Hz) - A unit of frequency equal to one cycle per second.
HIGH POTENTIAL TEST - A test which consists of the application of a voltage higher than the
rated voltage between windings and frame, or between two or more windings, for the purpose of
determining the adequacy of insulating materials and spacing against breakdown under normal
conditions. It is not the test of the conductor insulation of any one winding.
HORSEPOWER - A method of rating motors whereby values are determined by factors
including rotational speed and torque producing capability as well as other factors.
IN-RUSH CURRENT - See Locked Rotor Current.
INTERLOCK - Interrelates with other controllers. An auxiliary contact. A device connected in
such a way that the motion of one part is held back by another part.
INTRINSICALLY SAFE - A term used to define a level of safety associated with the electrical
controls used in some lift stations. Intrinsically safe equipment and wiring is incapable of
releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause
ignition of a hazardous atmospheric mixture - without the need for explosion-proof enclosures in
the hazardous area. Any associated devices must be outside the hazardous area with an
approved seal-off fitting used as an isolating barrier.
KILOWATT (KW) - A unit of measure of electrical power. One kilowatt equals 1000 watts. Used
where larger units of electrical power are measured.
LOCKED ROTOR CURRENT - (See Starting Amps).
LOCKOUT - A mechanical device which may be set to prevent the operation of a push-button or
other device.
MANUAL TRANSFER SWITCH - A switch designed so that it will disconnect the load from one
power source and reconnect it to another source while at no time allowing both sources to be
connected to the load simultaneously.
MEGGER OR MEGOHMETER - A high resistance range ohmmeter utilizing a power source for
measuring insulation resistance.
MEGOHM - A unit of resistance equal to one million ohms.
MOTOR CIRCUIT PROTECTOR - A molded case disconnect switch specifically designed for
motor circuits. It has a trip unit that operates on the magnetic principle only, sensing current in
each of the three poles with an adjustable trip point. It provides short circuit protection, required
by the National Electrical Code (NEC). It differs from a standard breaker in that it does not have
a thermal overload unit.
MOTOR EFFICIENCY - A measure of how effectively a motor converts electrical energy into
mechanical energy. Motor efficiency is never 100 percent. It is a variable that depends on a
given motor's performance. Tabulated at 100, 75 and 50 percent load, it is the ratio of power
output to power input.
MOTOR, ELECTRIC - A rotating device which converts electrical power into mechanical power.
155
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
MOTOR HORSEPOWER RATING - The motor horsepower nameplate rating fully-loaded at the
ambient temperature.
NEC - The National Electrical Code (NEC) is the standard of the National Board of Fire
Underwriters for electric wiring and apparatus, as recommended by the National Fire Protection
Association.
NEC CODE LETTER - Motors with 60 and 50 Hertz ratings shall be marked with a code letter
designating the locked-rotor KVA per horsepower on 60 Hertz.
NEMA - National Electrical Manufacturers Association, a non-profit trade association supported
by the manufacturers of electrical apparatus and supplies. NEMA promulgates standards to
facilitate understanding between the manufacturers and users of electrical products.
NFPA - National Fire Protection Association. Sponsors and publishes the National Electrical
Code (NEC).
NEUTRAL - The point common to all phases of a polyphase circuit, a conductor to that point, or
the return conductor in a single phase circuit. The neutral in most systems is grounded at or
near the point of service entrance only and becomes the grounded neutral.
NORMALLY OPEN and NORMALLY CLOSED - The terms "Normally Open" and "Normally
Closed" when applied to a magnetically operated switching device - such as a contactor or
relay, or to the contacts thereof - signify the position taken when the operating magnet is de-
energized. These terms pertain to all switches.
OHM - Unit of electrical resistance. One volt will cause a current of one ampere to flow through
a resistance of one ohm.
OHMMETER - A device for measuring electrical resistance expressed in ohms.
OVERLOAD PROTECTION - The effect of a device operative on excessive current, but not
necessarily on short circuit, to cause and maintain the interruption of current flow to the device
being governed. Re-set may be manual or automatic.
OVERLOAD RELAY - A relay that responds to electric load and operates at a pre-set value of
overload. The unit senses the current in each line to the motor and is either bimetallic, melting
alloy or solid state actuated. It may be of the non-compensated or ambient-compensated type,
and of a standard or fast-trip design.
PHASE (THREE PHASE CIRCUIT) - A combination of circuits energized by alternating
electromotive forces which differ in phase by one-third of a cycle (120 degrees). In practice, the
phases may vary several degrees from the specified angle.
PHASE MONITOR - A device in the control circuit of motors which monitors the three phase
voltage and protects against a phase loss (single phasing), under voltage (brown outs) and
phase reversal (improper phase sequence). Most are adjustable to set the nominal voltage and
some have a LED indicator to indicate acceptable voltage and phase conditions. The output
contacts are used to control the motor starters and provide signaling for telemetering.
PILOT LIGHT - A lamp available with various colored lenses designed to operate on a control
voltage. They are each turned On and Off to provide the required indication for specific
functions or alarm conditions. They are available in various sizes and voltage ratings. They are
each designed for a specific bulb style and base configuration and some have an integral
transformer to allow the use of low voltage bulbs. Full voltage incandescent bulbs are most
common, but neon bulbs are also used.
POWER FACTOR - The ratio of the true power to the volt-amperes in an alternating current
circuit. Power factor is expressed in a percent of unity either lagging for inductive loads or
leading for capacitive loads. Resistive loads produce a unity power factor.
PUSHBUTTON - Part of an electrical device, consisting of a button that must be pressed to
effect an operation.
RATED VOLTAGE - The voltage of electrical apparatus at which it is designed to operate.
156
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
REDUCED VOLTAGE AUTO-TRANSFORMER STARTER - A starter that includes an auto-
transformer to furnish reduced voltage for starting an alternating current motor. It includes the
necessary switching mechanism. This is the most widely used reduced voltage starter because
of its efficiency and flexibility.
RELAY - An electric device that is designed to interpret input conditions in a prescribed manner
and, after specified conditions are met, to respond and cause contact operation or similar abrupt
changes in associated electric control circuits.
RELAY, ELECTROMAGNETIC - A relay controlled by electromagnetic means, to open and
close electric contacts.
RELAY, SOLID STATE - A completely electronic switching device with no moving parts or
contacts.
RPM - Revolutions per minute of the motor/pump rotating assembly.
REMOTE CONTROL - Control function initiation or change of electrical device from a remote
point.
RESISTANCE - The non-reactive opposition which a device or material offers to the flow of
direct or alternating current. Usually measured in ohms.
SAFETY SWITCH - An enclosed, manually-operated disconnecting switch, which is horsepower
and current rated. Disconnects all power lines simultaneously.
SEAL FAILURE ALARM - The sensing and indication of the intrusion of water into the oil-filled
seal chamber between the inner and outer shaft seal of a submersible pump.
SELECTOR SWITCH - A multi-position switch which can be set to the desired mode of
operation.
SERVICE FACTOR - A safety factor designed and built into some motors which allows the
motor, when necessary, to deliver greater than its rated horsepower.
SINGLE PHASE - A circuit that differs in phase by 180 degrees. Single phase circuits have two
conductors, one of which may be a neutral, or three conductors, one of which is neutral.
STANDBY POWER SUPPLY - The power supply that is available to furnish electric power
when the normal power supply is not available.
STAR CONNECTION - Same as a "Y" or "Wye" connection. This three-phase connection is so
called because, schematically, the joint of the "Y" points looks like a star.
STARTER - A device used to control the electrical power to motors and provide overload
protection as required by the NEC. The starter can be operated manually, electrically, or by
automatic pilot devices. A starter has two basic parts - a contactor for power switching and an
overload relay for protection.
STARTING AMPS (LOCKED ROTOR) - The maximum current drawn by the motor during the
starting period.
STARTING RELAY - A relay - actuated by current, voltage or the combined effect of current
and voltage - which is used to perform a circuit-changing function in the primary winding of
single phase induction motor within a pre-determined range of speed as the motor accelerates;
and to perform the reverse circuit-changing operation when the motor is disconnected from the
supply line. One of the circuit changes that is usually performed is to open or disconnect the
auxiliary winding (starting) circuit.
SUBMERSIBLE MOTOR - A motor whose housing and terminal box is so designed that the
motor can run underwater - completely submerged at an allowable temperature.
SURGE ARRESTER - A protective device for limiting surge voltages on equipment by
discharging or bypassing surge current; it prevents continued flow of follow current to ground,
and is capable of repeating these functions as specified.
SWITCH - A device for making, breaking, or changing connections in a circuit.
TELEMETERING - The transmitting of alarm and control signals to and from remote lift station
157
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
controls and a central monitoring location.
TERMINAL BLOCK - An insulating base equipped with terminals for connecting wires.
THERMAL OVERLOAD PROTECTOR - Device, either a bimetal element or electric circuit,
which protects motor windings from excessive temperature by opening a set of contacts. This
device may reach its pre-set trip point as a result of ambient temperature, current, or both. May
be automatic or manually set.
THREE PHASE CIRCUIT - A combination of circuits energized by alternating electromotive
sources which differ in phase by one third of a cycle - that is, 120 degrees. A three phase circuit
may be three wires or four wires with the fourth wire being connected to the neutral point of the
circuit which may be grounded.
TIME CLOCK - A device used to schedule electrical On/Off cycling operations. The device may
be solid state or mechanical designed using a synchronous motor. The cycling operation must
be programmed manually. The time clocks may operate in any increments of days, weeks,
minutes, or hours.
TIME DELAY RELAY (TDR) - A device with either mechanical or solid state output contacts
that performs a timing function upon energization or control signal.
TRANSDUCER - A device to condition and transform an analog signal to a specific variable
output electrical signal proportional to the input signal. Typical inputs include variable pressure,
level, voltage or current. Some common outputs are O to 1ma, 4 to 20 ma, and various MVDC
signals. A transducer must be specifically designed to be compatible with the input/output
requirements of the total system.
TRANSFORMER - A static electric device consisting of a single winding, or two or more
coupled windings, used to transfer power by electromagnetic induction between circuits at the
same frequency, usually with changed values of voltage and current.
UNDERWRITERS LABORATORIES, INC. (UL) - An independent, non-profit U.S. organization
that tests products for safety.
VFD - Variable frequency drive.
VOLTAGE (NOMINAL A) - A nominal value assigned to a circuit or system for the purpose of
conveniently designating its voltage class (as 120/240, 480/240, 600, etc.). The actual voltage
at which a circuit operates can vary from the nominal within a range that permits satisfactory
operation of equipment.
VOLTMETER - An instrument for measuring voltage.
WATT - A unit of measure of electrical power.
WYE CONNECTION - See Star Connection.
158
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
159
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
160
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Well Selection Section
Basically, a well is a hole drilled into an aquifer. A pipe and a pump are used to pull water out of
the ground, and a screen filters out unwanted particles that could clog the pipe. Wells come in
different shapes and sizes, depending on the type of material the well is drilled into and how
much water is being pumped out.
161
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Selecting an Optimum Pumping Rate
Before a well can be completed with the necessary pumping equipment, it should be tested for
capacity and proper operation. When the well was drilled, the driller and geologist kept close
watch of the amount of water production that had been obtained. The development techniques
used can also be useful in estimating a wells production rate. However, the driller will normally
know what to expect based on his experience, and the geologist or hydrologist will also obtain
information on other nearby wells to bracket the expected production rate. If the well was drilled
with air rotary, the airlift at the time of drilling also can serve as a baseline to estimate the wells
production rate. Either way, the well is normally pump tested following well development.
A pumping test is normally conducted for at least eight hours in order to estimate a wells
maximum production rate. Ideally, a twenty-four hour step test is conducted. A step test is a
variable rate pumping test, typically conducted for 24 hours at up to six different pumping rates.
Typically, the well will be pumped at the lower estimated maximum pumping rate for the first four
hours.
The pumping rate is then adjusted upwards in equal amounts every four hours until 24 hours of
pumping have been completed. The personnel conducting the test keep track of the water levels
in the well to ensure that the steps are not too large and not too small.
In the end, the optimum pumping rate is selected following a careful review and comparison of
the water level data for each rate. The wells specific capacity (Sc) is then determined. Specific
capacity is the gallons per minute the well can produce per foot of drawdown. Specific capacities
for each of the pumping steps are compared. The highest Sc observed is normally associated
with the optimum pumping rate. That rate should also have resulted in stabilized pumping levels
or drawdown.
Well pumping test being conducted in photograph below. (Notice the portable electric generator
for powering the pump. The Hydrogeologist is using a depth probe to measure the drop in the
static water level.)
162
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Selection of Pumping Equipment
The proper selection of pumping equipment for a well is of great importance. The primary factors
that must be considered before selecting the well pump are: flow rate, line pressure, pumping lift
(total dynamic head), power requirements (and limitations), and size of piping. Each of these
components must be considered together when selecting well pumps.
The Total Dynamic Head (TDH) is the sum of the total static head, the total friction head
and the pressure head.
Pressure Head
The pressure head at any point where a pressure gauge is located can be converted from pounds
per square inch (PSI) to feet of head by multiplying by 2.31. For example, 20 PSI is equal to 20
times 2.31 or 46.2 feet of head. Most city water systems operate at 50 to 60 PSI, which, as
illustrated in Table 1, explains why the centers of most city water towers are about 130 feet above
the ground.
Table 1. Pounds per square inch (PSI) and equivalent head in feet of water.
163
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
30 69.3
35 80.8
40 92.4
45 104
50 115
55 127
60 138
65 150
70 162
75 173
80 185
85 196
90 208
95 219
100 231
Friction Head
Friction head is the energy loss or pressure decrease due to friction when water flows through
pipe networks. The velocity of the water has a significant effect on friction loss. Loss of head due
to friction occurs when water flows through straight pipe sections, fittings, valves, around corners,
and where pipes increase or decrease in size. Values for these losses can be calculated or
obtained from friction loss tables. The friction head for a piping system is the sum of all the friction
losses.
Velocity Head
Velocity head is the energy of the water due to its velocity. This is a very small amount of
energy and is usually negligible when computing losses in an irrigation system.
Suction Head
A pump operating above a water surface is working with a suction head. The suction head
includes not only the vertical suction lift, but also the friction losses through the pipe, elbows, foot
valves, and other fittings on the suction side of the pump. There is an allowable limit to the suction
head on a pump and the net positive suction head (NPSH) of a pump sets that limit.
The theoretical maximum height that water can be lifted using suction is 33 feet. Through
controlled laboratory tests, manufacturers determine the NPSH curve for their pumps. The NPSH
curve will increase with increasing flow rate through the pump. At a certain flow rate, the NPSH
is subtracted from 33 feet to determine the maximum suction head at which that pump will operate.
For example, if a pump requires a minimum NPSH of 20 feet the pump would have a maximum
suction head of 13 feet. Due to suction pipeline friction losses, a pump rated for a maximum
suction head of 13 feet may effectively lift water only 10 feet. To minimize the suction pipeline
friction losses, the suction pipe should have a larger diameter than the discharge pipe.
Operating a pump with suction lift greater than it was designed for, or under conditions with
excessive vacuum at some point in the impeller, may cause cavitation. Cavitation is the implosion
of bubbles of air and water vapor and makes a very distinct noise like gravel in the pump. The
implosion of numerous bubbles will eat away at an impeller and it eventually will be filled with
holes.
164
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Power Requirements
The power added to water as it moves through a pump can be calculated with the following
formula:
Q x TDH
WHP = ----------- (1)
3960
where:
However, the actual power required to run a pump will be higher than this because pumps and
drives are not 100 percent efficient. The horsepower required at the pump shaft to pump a
specified flow rate against a specified TDH is the Brake Horsepower (BHP) which is calculated
with the following formula:
WHP
BHP = ---------------------- (2)
Pump Eff. x Drive Eff.
Pump Eff. -- Efficiency of the pump usually read from a pump curve and having a value
between 0 and 1.
Drive Eff. -- Efficiency of the drive unit between the power source and the pump. For direct
connection this value is 1, for right angle drives the value is 0.95 and for belt drives it can vary
from 0.7 to 0.85.
RPM2
(-----)2 X TDH1 = TDH2 (4)
RPM1
RPM2
(-----)3 x BPH1 = BPH2 (5)
RPM1
where:
RPM1 = Initial revolutions per minute setting
RPM2 = New revolutions per minute setting
165
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
GPM = Gallons per Minute
(subscripts same as for RPM)
TDH = Total Dynamic Head
(subscripts same as for RPM)
BHP = Brake Horsepower
(subscripts same as for RPM)
As an example, if the RPM are increased by 50 percent, the flow rate will increase by 50
percent, the TDH will increase 2.25 times, and the required BHP will increase 3.38 times that
required at the lower speed. It is easy to see that with a speed increase the BHP requirements
of a pump will increase at a faster rate than the head and flow rate changes.
Pump Efficiency
Manufacturers determine by tests the operating characteristics of their pumps and publish the
results in pump performance charts commonly called "pump curves."
A typical pump curve for a horizontal centrifugal pump. NPSH is the Net Positive Suction
Head required by the pump and TDSL is the Total Dynamic Suction Lift available (both at
sea level).
All pump curves are plotted with the flow rate on the horizontal axis and the TDH on the vertical
axis. The curves are often shown for a centrifugal pump tested at different RPM. Each curve
indicates the GPM versus TDH relationship at the tested RPM. In addition, pump efficiency lines
have been added and wherever the efficiency line crosses the pump curve lines that number is
what the efficiency is at that point. Brake horsepower (BHP) curves have also been added; they
slant down from left to right. The BHP curves are calculated using the values from the efficiency
lines. At the top of the chart is an NPSH curve with its scale on the right side of the chart.
Solution: Follow the dashed vertical line from 900 GPM until it crosses the dashed horizontal line
from the 120 feet of TDH. At this point the pump is running at a peak efficiency just below 72
percent, at a speed of 1600 RPM. If you look at the BHP curves, this pump requires just less than
40 BHP on the input shaft. A more accurate estimate of BHP can be calculated with equations 1
and 2.
Using equation 1, the WHP would be [900 x 120] / 3960 or 27.3, and from equation 2 the BHP
would be 27.3 / 0.72 or 37.9, assuming the drive efficiency is 100 percent. The NPSH curve was
used to calculate the Total Dynamic Suction Lift (TDSL) markers at the bottom of the chart. Notice
that the TDSL at 1400 GPM is 10 feet, but at 900 GPM the TDSL is over 25 feet.
166
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Changing Pump Speed
In addition, suppose this pump is connected to a diesel engine. By varying the RPM of the engine
we can vary the flow rate, the TDH and the BHP requirements of this pump. As an example, let's
change the speed of the engine from 1600 RPM to 1700 RPM. What effect does this have on the
GPM, TDH and BHP of the pump?
Solution: We will use equations 3, 4 and 5 to calculate the change. Using equation 3, the change
in GPM would be (1700/1600) x 900, which equals 956 GPM. Using equation 4, the change in
TDH would be (1700/1600)2 x 120, which equals 135.5 feet of TDH. Using equation 5, the change
in BHP would be (1700/1600)3 x 37.9, which equals 45.5 BHP. This point is plotted on Figure 2
as the circle with the dot in the middle. Note that the new operating point is up and to the right of
the old point and that the efficiency of the pump has remained the same. When a pump has been
selected for installation, a copy of the pump curve should be provided by the installer. In addition,
if the impeller(s) was trimmed, this information should also be provided. This information will be
valuable in the future, especially if repairs have to be made.
For example: A municipal supply well has been tested and determined to yield 500gpm. The
well was constructed with 10 inch casing that has been perforated from 200 to 500 feet below the
ground surface within an unconfined aquifer. The static water level has been measured at 100
feet while the drawdown at 500gpm has been estimated at 80 feet. The full level of the storage
tank for the well exerts about 87psi at the wellhead and is connected to the well via a 12-inch
distribution main. Three-phase power is available and 4-inch column pipe is to be used down the
hole. The pump intake is to be set at 180 feet.
Before we can select an appropriate pump, we first need to determine what the total dynamic
head is. After referring to a friction loss table for flow in 4 inch and 12-inch pipe; we determine
that the friction losses in the 4 inch pipe will be about 24 feet per 100 foot, while losses in the 12
inch main are negligible.
This leads us to determine that there will be about 43 feet of friction loss through the 4-inch pipe.
We also know that the total lift is equal to the drawdown, plus the distance to the land surface
from the static water level, plus the vertical distance to the full level of the storage tank. We know
from physics that for every foot of water there is .433psi of pressure or 2.31ft of head for every 1
psi. The line pressure at the well head is equal to the height of the column of water above the
well head, which gives us a line pressure at the well head of 87psi or 200 feet of water. The total
lift from the pump to the wellhead 180 feet and equivalent to 78psi. So the total dynamic head is
equivalent to a lift of 380 feet or an equivalent pressure of about 165psi at the pump, plus about
43 feet of friction loss. Therefore, in order to pump 500gpm under these circumstances, the
pump that is selected should have its most efficient operating range in the neighborhood of 423
feet total lift. We then look at performance curves from the various pump manufacturers to
determine the best pump and power combination for the application.
167
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Because this is a municipal supply well that is pumping directly into the distribution system, we
will choose a submersible turbine for the job rather than a line shaft turbine, which must be
lubricated. Upon looking at the curves for this application, one will find that a 75HP, 8in, 5 stage,
submersible pump will do the job most efficiently without risking the over-pumping of the well.
Elements of Total Dynamic Head for the proper selection of pumping equipment.
168
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A new 8-inch submersible pump and motor with 6 inch column pipe
about to be installed in a high capacity municipal supply well.
The well vent pipe should be at least inch in diameter, 8 inches above the finished grade, and
be turned down, with the opening screened with a minimum 24-mesh durable screen to prevent
entry of insects. Only approved well casing material meeting the requirements of the Code may
be utilized.
In addition, frost protection should be provided by use of insulation or pump house. Turbine and
submersible pumps are normally used. Any pressure, vent, and electric lines to and from the
pump should enter the casing only through a watertight seal.
Pumps and pressure tanks may be located in basements and enclosures. However, wells should
not be located within vaults or pits, except with a variance permit. If the pump discharge line
passes through the well casing underground, an approved pitless adapter should be installed.
The well manifold should include an air relief valve, flow meter, sample port, isolation valve, and
a check valve. If the well should need rehabilitation, additional construction, or repair, it must be
done in compliance with the State or Local Water Well Construction Codes.
169
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pump Surging/Raw-hiding or Backwashing
Pump surging (sometimes called Rawhiding) involves the repeated pumping and resting of the
well for well development purposes. A column of water that is withdrawn through a pump is
allowed to surge back into the well by turning the pump on and off repeatedly. However, sufficient
time for the pump motor to stop reverse rotation must be allowed, such that pump damage can
be avoided. Occasionally, water is pumped to waste until it is clear of sediment before again
shutting the pump off. This is done to permanently remove the sediments that are being
developed by the backwashing action. The process continues until sufficient quantities of water
produced are consistently clean.
Surge-blocks, swabs, or plungers are disc shaped devices made to fit tightly within the well.
Their edges are usually fitted with rubber or leather rings to make a tight seal against the well
casing. Pipe sections are then attached to the surge-block to lower it into the well, above the well
screen, and about 15 feet below the water level. The assembly is then repeatedly lifted up and
down.
The up and down action of the surge-block creates suction and compression strokes that force
water in and out of the well through the screened interval, gravel pack, and aquifer. It works like
a plunger in the way that it removes small obstructions and sediments from the well. The surge-
block is slowly lowered each time resistance begins to decrease.
Once the top of the screen is reached, the assembly may be removed and accumulated sediment
either bailed or airlifted out of the well. Surging within known problem areas of the screened
interval may be conducted also. The cycle of swabbing and removing sediment should be
continued until resistance to the action of the swab or block is significantly lower than at the start
of development. The development is complete when the amount of sediment removed is both
significantly and consistently less than when surging began.
Airlifting (or Air surging) involves the introduction of large short blasts of air within the well that
lifts the column of water to the surface and then drop it back down again. Continuous airlifting or
air pumping from the bottom of the well is then used occasionally to lift sediments out of the well.
Airlift development is most often used following initial pump surging, and is employed to confirm
that the well is productive, since the injection of air into a plugged well may result in casing or
screen failure.
Air lifting development is most often done with a rotary drilling rig through the drill string.
Sometimes special air diffusers or jets are used to direct the bursts of air into preferred directions
(see jetting). Piping is inserted into the well and intermittent blasts of air are introduced as the
piping is slowly lowered into the well. Sometimes surfactant or drill foam is added to aid in the
efficiency of sediment removal and cleaning of the well. Air surging development is much the
same as drilling the well with air rotary; only the well has already been constructed.
Specialized air development units are available independent of a drilling rig, which may be used
as well. The great thing about air rotary drilled wells is that they are essentially developed while
drilling, particularly in hard rock formations, when greater than 100 gallons per minute is being
lifted to the surface. The development of a filter pack (if used) in such wells is still recommended.
170
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Jetting is a type of well development technique in which water and/or air is jetted or sprayed
horizontally into the well screen. This method is especially suited for application in stratified and
unconsolidated formations. The water or air is forced through nozzles in a specially designed
jetting tool (or simply drilled pipe and fittings) at high velocities. Normally, air lifting or pumping is
used in conjunction with jetting methods in order to minimize potential damage to the well bore.
Jetting with water alone can be so powerful that the sediment, which is supposed to be removed,
can be forced into the formation causing clogging problems. This is why pumping or airlifting while
jetting with water is so important. Jetting is normally conducted from the bottom of the well screen
upwards.
Rotary Rig
A rotary rig is often used to provide the fluid or air with sustained pressure while the tool is slowly
raised up through the screen. As jetting proceeds, sediment is occasionally removed from the
bottom of the well bore thru the use of a bailer or airlifting. Several passes should be made over
the length of screen until sediment generation drops off. Air is normally used for jetting in shallow
aquifers (less than 300 feet of submergence) due to limited supply pressures. Jetting in PVC
constructed wells is not recommended since the high velocities of fluid and sediment can erode
and possibly cut through the plastic well screen. In addition, wells constructed with louvered or
slotted screen limit the effectiveness of jetting. In these types of wells, surging may be more
effective.
171
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Surge of Air Developing a Well.
Jetting Nozzle
that can be
attached to
drill pipe.
In the best of situations, a combination of methods can be used to ensure the efficient
development and operation of a well.
172
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Preparing an explosive charge to hydrofract or loosen or dislodge any debris or
corrosion inside an existing well casing. This explosive material is made in 25 or 50 foot
lengths and has a blasting cap to start the explosion. Believe it or not, you cannot hear
the explosion, since it is deep underwater. The bottom photo is the remains of the
explosive charge. This procedure will usually increase well production.
173
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Blasting cap on the explosive cord. Below, some of the debris from inside the well casing
following the explosion. After talking to this man, I found out that after 9-11, he had to
increase his fees because of the ATF and new rules concerning explosives. Be prepared
to pay through the nose for this treatment process. Consider this expense the price of
admission to having adequate water to supply your customers demands.
174
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
New EPA Rules for Distribution
Reduction of Lead in Drinking Water Act
Congress passed Public Law 111-380 or The Reduction of Lead in Drinking Water Act, in 2010.
Its set to go into effect Jan. 4, 2014, which means municipalities, water districts and developers
who work with and pay for water infrastructure need to be preparing.
Lead, a metal found in natural deposits, is commonly used in household plumbing materials and
water service lines. The greatest exposure to lead is swallowing or breathing in lead paint chips
and dust.
But lead in drinking water can also cause a variety of adverse health effects. In babies and
children, exposure to lead in drinking water above the action level can result in delays in physical
and mental development, along with slight deficits in attention span and learning abilities. In
adults, it can cause increases in blood pressure. Adults who drink this water over many years
could develop kidney problems or high blood pressure.
Lead is rarely found in source water, but enters tap water through corrosion of plumbing materials.
Homes built before 1986 are more likely to have lead pipes, fixtures and solder. However, new
homes are also at risk: even legally lead-free plumbing may contain up to 8 percent lead. The
most common problem is with brass or chrome-plated brass faucets and fixtures which can leach
significant amounts of lead into the water, especially hot water.
Congress enacted the Reduction of Lead in Drinking Water Act on January 4, 2011, to amend
Section 1417 of the Safe Drinking Water Act (SDWA) regarding the use and introduction into
commerce of lead pipes, plumbing fittings or fixtures, solder and flux. The Act established a
prospective effective date of January 4, 2014, which provided a three year timeframe for affected
parties to transition to the new requirements.
Beginning in the 1970s, lead concentrations in air, tap water, food, dust, and soil began to be
substantially reduced, resulting in significantly reduced blood lead levels (BLLs) in children
throughout the United States. However, children are still being exposed to lead, and many of
these children live in housing built before the 1978 ban on lead-based residential paint. These
homes might contain lead paint hazards, as well as drinking water service lines made from lead,
lead solder, or plumbing materials that contain lead. Adequate corrosion control reduces the
leaching of lead plumbing components or solder into drinking water.
The majority of public water utilities are in compliance with the Safe Drinking Water Act Lead and
Copper Rule (LCR) of 1991. However, some children are still exposed to lead in drinking water.
175
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
EPA is reviewing LCR, and additional changes to the rule are expected that will further protect
public health. Childhood lead poisoning prevention programs should be made aware of the results
of local public water system lead monitoring measurement under LCR and consider drinking water
as a potential cause of increased BLLs, especially when other sources of lead exposure are not
identified.
This report does not provide a comprehensive review of the current scientific literature but builds
on other comprehensive reviews, including the Toxicological Profile for Lead and the 2005 CDC
statement Preventing Lead Poisoning Among Young Children). When investigating cases of
children with BLLs at or above the reference value established as the 97.5 percentile of the
distribution of BLLs in U.S. children aged 15 years, drinking water should be considered as a
source. The recent recommendations from the CDC Advisory Committee on Childhood Lead
Poisoning Prevention to reduce or eliminate lead sources for children before they are exposed
underscore the need to reduce lead concentrations in drinking water as much as possible.
Background
Lead is a relatively corrosion-resistant, dense, ductile, and malleable metal that has been used
by humans for at least 5,000 years. During this time, lead production has increased from an
estimated 10 tons per year to 1,000,000 tons per year, accompanying population and economic
growth. The estimated average BLL for Native Americans before European settlement in the
Americas was calculated as 0.016 g/dL. During 19992004, the estimated average BLL was 1.9
g/dL for the non-institutionalized population aged 15 years in the United States, approximately
100 times higher than ancient background levels, indicating that substantial sources of lead
exposure exist in the environment.
January 4, 2014
On January 4, 2014, the "Reduction of Lead in Drinking Water Act" becomes effective
nationwide. This amendment to the 1974 Safe Drinking Water Act reduces the allowable lead
content of drinking water pipes, pipe fittings and other plumbing fixtures. Specifically, as of
January 4, 2014, it shall be illegal to install pipes, pipe fittings, and other plumbing fixtures that
are not "lead free." "Lead free" is defined as restricting the permissible levels of lead in the wetted
surfaces of pipes, pipe fittings, other plumbing fittings and fixtures to a weighted average of not
more than 0.25%.
This new requirement does not apply to pipes, pipe fittings, plumbing fittings or fixtures that are
used exclusively for non-potable services such as manufacturing, industrial processing, irrigation,
outdoor watering, or any other uses where water is not anticipated to be used for human
consumption. The law also excludes toilets, bidets, urinals, fill valves, flushometer valves, tub
fillers, shower valves, service saddles, or water distribution main gate valves that are 2 inches in
diameter or larger.
176
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Accordingly, effective January 4, 2014, only accepted products that are "lead free" may be utilized
with regards to any plumbing providing water for human consumption (unless meeting the
exception outlined above). Installers and inspectors may check their products to determine if they
meet these requirements by looking to see if the products are certified to the following standards:
A. NSF/ANSI 61-G;
B. NSF/ANSI 61, section 9-G; OR
C. Both NSF/ANSI 61 AND NSF/ANSI 372.
As existing products may still be utilized for non-potable purposes. The burden of following these
requirements shall be on installers. Plumbing inspectors (who will be covering these
requirements in continuing education) shall have the right to question installers, who must be able
to prove that no non-compliant products are installed on or after January 4, 2014.
Does The Reduction of Lead in Drinking Water Act apply to all water infrastructure?
No. Service brass used in industrial or non-potable infrastructure is exempt from the law. Also,
the law only applies to wetted surfaces. Saddles and other exterior pipe are also exempt.
If you are a homeowner and are concerned about potential lead exposure from your private water
system, have your water tested by a state certified water testing laboratory in your area.
177
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Is there a difference between low-lead and no-lead brass?
No. There are several terms flying around to refer to the low-lead service brass products no
lead, lead free, low lead, and others. They all refer to the same products: service brass with
0.25 percent or less lead on wetter surfaces.
Instead of lead, manufacturers will have to use different and more expensive materials and take
more care in the manufacturing process. That means the cost of the new low-lead brass will be
25 to 40 percent higher than traditional brass pipe fittings and meters.
What are the biggest concerns for developers, municipalities and water districts?
There are two big concerns that should inspire anyone responsible for laying water
infrastructure to act soon. If you have inventory of traditional services brass, now is the time to
find a place to use it.
The second concern is cost. If you dont have an inventory of traditional brass but you have
upcoming projects, this might be the ideal time to start them. Order traditional brass pipe fittings
and meters from suppliers who are offering their traditional service brass at steep discounts ahead
of the new law. After the law goes into effect, service brass costs will skyrocket and significantly
increase your costs.
Lead-free Alternatives
There are several materials that utilities should consider when selecting a lead-free meter
alternative. Various options include epoxy coated ductile and cast iron, stainless steel, low lead
bronze and composite.
When choosing a lead-free alternative material, utilities must consider traditional meter
requirements such as strong flow capability and durability. However, the difference between lead-
free and zero lead meters should also be considered. Some lead-free meters contain as much
as 0.25 percent lead.
While a 0.25 percentage of lead in meters allows utilities to meet current regulations,
implementing these lead-free meters could put utilities at risk for the cost of another meter
change out should future regulations require complete lead elimination from water meters. Most
water meters are expected to last more than 20 years, meaning that the next amendment to
SDWA could come before the meter fleet must be replaced. This could be potentially devastating
for utility companies still using older systems should completely lead-free meters become
mandated.
Composite Meters
Composite meters are one example of a zero lead alternative that is not susceptible to future no-
lead regulations. This meter material is also gaining popularity due to its strength and cost stability.
Composite meters do not depend on metal pricing fluctuations and, more importantly, have zero
lead as opposed to low lead or even bronze meters.
178
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Made of materials that have already proven their strength and durability in the automotive and
valve industries, composite meters boast longevity and resistance to corrosion from aggressive
water and from the chlorinated chemicals used to make water drinkable. Composite meters are
also equipped to withstand the pressure required to maintain a water system.
Composite meters are constructed using a blend of plastic and fiberglass. When compared to
bronze water meter products, composites are lighter and require less time and energy to
manufacture, ship and install. Composite meters attached with composite threads have been
found to eliminate the friction feeling typically experienced with metal threads and metal
couplings, facilitating easier installation.
Through comprehensive testing, composite meters have demonstrated a burst pressure that is
significantly greater than bronze and an equal longevity. Composite technology today allows for
better, more environmentally friendly composite products that will last up to 25 years in residential
applications. Manufacturers have a wide range of lead-free or zero lead products on the market
and it is critical that utilities consider all of their options when selecting a new fleet of meters.
Most importantly, everyone deserves access to safe, clean water. It is essential that
manufacturers continually develop and deliver products that meet the highest standards for
safety, quality, reliability and accuracy to ensure availability to, and conservation of, this most
precious resource.
A nationwide survey conducted in 1990 indicated that 3.3 million lead service lines were in use,
and the areas where they were most likely to be used were, again, the Midwestern and
northeastern regions of the United States. This survey also estimated that approximately 61,000
lead service lines had been removed through voluntary programs during the previous 10 years.
Research on exposure to lead in water increased as concern about the topic increased, and
efforts were made to establish a level of lead in water that, at the time of the studies, was
considered acceptable.
179
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A 1972 study in Edinburgh, Scotland, obtained 949 first-flush water samples (i.e., samples of
water from the tap that have been standing in the plumbing pipes for at least 6 hours) matched
with 949 BLLs, as well as 205 running water samples matched to 205 BLLs . No dose-response
relationship could be determined when comparing BLLs with four levels of lead in both first-flush
water and in running water (<0.24 mol/L; 0.240.47 mol/L; 0.481.43 mol/l; and 1.44 mol/L).
The study concluded that the findings challenged whether it was necessary to lower the water
lead concentration to <100 ppb, which at that time was the acceptable concentration established
by the World Health Organization. However, the study also reported that low levels of
environmental lead exposure could have adverse health effects; therefore, knowing the degree
of lead exposure from household water relative to other sources is important. Another study, in
1976, of 129 randomly selected homes in Caernarvonshire, England, reported a similar finding,
describing the relationship between blood and water lead as slight.
All systems must provide periodic monitoring for microbiological contaminants and some chemical
contaminants. The frequency of sampling and the chemicals that must be tested for depend on
the physical size of the water system, the water source, and the history of analyses. General
sampling procedures are covered in more detail under the topic of Public Health Considerations
to follow.
State policies vary on providing laboratory services. Some States have laboratory facilities
available to perform all required analyses or, in some cases, a certain number of the required
analyses for a system. In most States, there is a charge for all or some of the laboratory services.
Sample analyses that are required and cannot be performed by a State laboratory must be taken
or sent to a State-certified private laboratory.
If the analysis of a sample exceeds an MCL, resampling is required, and the State should be
contacted immediately for special instructions. There is always the possibility that such a sample
was caused by a sampling or laboratory error, but it must be handled as though it actually was
caused by contamination of the water supply.The results of all water analyses must be periodically
sent to the State of origin. Failure to have the required analysis performed or to report the results
to the State usually will result in the water system being required to provide PN. States typically
have special forms for submitting data, and specify a number of days following the end of the
monitoring period by which the form is due.
180
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
In spite of the fact that use of chlorine has almost completely eliminated occurrences of
waterborne diseases in the United States, there is no concern for byproducts formed when
chlorine reacts with naturally occurring substances in raw water (such as decaying vegetation
containing humic and fulvic acids).
The first group of byproduct chemicals identified was tri-halo-methane (THM), a group of organic
chemicals that are known carcinogens (cancer-forming) to some animals, so they are assumed
also to be carcinogenic to humans. Other byproducts of disinfection have been identified that may
be harmful, and there also is concern now that disinfectants themselves may cause some adverse
health reactions.
The reports must be prepared yearly by every community water supply system. Water systems
serving more than 10,000 people must mail the report to customers. Small systems must notify
customers as directed by the State primacy agency. Beginning in the year 2000, reports were to
be delivered by July 1 of the calendar year.
A water system that only distributes purchased waster (i.e., a satellite system) must prepare the
report for their consumers. Information on the source water and chemical analyses must be
furnished to the satellite system by the system selling the water (parent company).
Some States are preparing much of the information for their water systems, but the system
operator still must add local information. Templates for preparing a report also are available from
the American Water Works Association (AWWA) and the National Rural Water Association
(NRWA). Water system operators should keep in mind that CCRs provide an opportunity to
educate consumers about the sources and quality of their drinking water. Educated consumers
are more likely to help protect drinking water sources and be more understanding of the need to
upgrade the water system to make their drinking water safe.
181
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
182
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Glossary
A
Absolute Pressure: The pressure above zone absolute, i.e. the sum of atmospheric and gauge
pressure. In vacuum related work it is usually expressed in millimeters of mercury. (mmHg).
Aerodynamics: The study of the flow of gases. The Ideal Gas Law - For a perfect or ideal gas
the change in density is directly related to the change in temperature and pressure as
expressed in the Ideal Gas Law.
Air Break: A physical separation which may be a low inlet into the indirect waste receptor from
the fixture, or device that is indirectly connected. You will most likely find an air break on waste
fixtures or on non-potable lines. You should never allow an air break on an ice machine.
Air Gap Separation: A physical separation space that is present between the discharge vessel
and the receiving vessel, for an example, a kitchen faucet.
Altitude-Control Valve: If an overflow occurs on a storage tank, the operator should first check
the altitude-control valve. Altitude-Control Valve is designed to, 1. Prevent overflows from the
storage tank or reservoir, or 2. Maintain a constant water level as long as water pressure in the
distribution system is adequate.
Angular Motion Formulas: Angular velocity can be expressed as (angular velocity = constant):
= / t (2a)
where
= angular velocity (rad/s)
= angular displacement (rad)
t = time (s)
where
o = angular velocity at time zero (rad/s)
= angular acceleration (rad/s2)
where
d = change of angular displacement (rad)
dt = change in time (s)
183
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Atmospheric Pressure: Pressure exerted by the atmosphere at any specific location. (Sea level
pressure is approximately 14.7 pounds per square inch absolute, 1 bar = 14.5psi.)
B
Backflow Prevention: To stop or prevent the occurrence of, the unnatural act of reversing the
normal direction of the flow of liquid, gases, or solid substances back in to the public potable
(drinking) water supply. See Cross-connection control.
Backflow: To reverse the natural and normal directional flow of a liquid, gases, or solid
substances back in to the public potable (drinking) water supply. This is normally an
undesirable effect.
Backsiphonage: A liquid substance that is carried over a higher point. It is the method by which
the liquid substance may be forced by excess pressure over or into a higher point. Is a condition
in which the pressure in the distribution system is less than atmospheric pressure. In other words,
something is sucked into the system because the main is under a vacuum.
Bernoulli's Equation: Describes the behavior of moving fluids along a streamline. The Bernoulli
Equation can be considered to be a statement of the conservation of energy principle appropriate
for flowing fluids. The qualitative behavior that is usually labeled with the term "Bernoulli effect"
is the lowering of fluid pressure in regions where the flow velocity is increased. This lowering of
pressure in a constriction of a flow path may seem counterintuitive, but seems less so when you
consider pressure to be energy density. In the high velocity flow through the constriction, kinetic
energy must increase at the expense of pressure energy.
184
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A special form of the Eulers equation derived along a fluid flow streamline is often called the
Bernoulli Equation.
For steady state incompressible flow the Euler equation becomes (1). If we integrate (1) along
the streamline it becomes (2). (2) can further be modified to (3) by dividing by gravity.
Head of Flow: Equation (3) is often referred to as the head because all elements have the unit
of length.
Since energy is conserved along the streamline, (4) can be expressed as (6). Using the equation
we see that increasing the velocity of the flow will reduce the pressure, decreasing the velocity
will increase the pressure.
This phenomena can be observed in a venturi meter where the pressure is reduced in the
constriction area and regained after. It can also be observed in a pitot tube where the stagnation
pressure is measured. The stagnation pressure is where the velocity component is zero.
185
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Bernoulli's Equation Continued:
Pressurized Tank
If the tanks are pressurized so that product of gravity and height (g h) is much less than the
pressure difference divided by the density, (e4) can be transformed to (e6).
The velocity out from the tanks depends mostly on the pressure difference.
can be calculated as
V2 = [(2/(1-(0.01)2) ( (0.2 - 0.1)x106 /1x103 + 9.81 x 10)]1/2 = 19.9 m/s
Bingham Plastic Fluids: Bingham Plastic Fluids have a yield value which must be exceeded
before it will start to flow like a fluid. From that point the viscosity will decrease with increase of
agitation. Toothpaste, mayonnaise and tomato catsup are examples of such products.
Boundary Layer: The layer of fluid in the immediate vicinity of a bounding surface.
Bulk Modulus and Fluid Elasticity: An introduction to and a definition of the Bulk Modulus
Elasticity commonly used to characterize the compressibility of fluids.
where
E = bulk modulus elasticity
dp = differential change in pressure on the object
dV = differential change in volume of the object
V = initial volume of the object
where
d = differential change in density of the object
= initial density of the object
An increase in the pressure will decrease the volume (1). A decrease in the volume will increase
the density (2).
The SI unit of the bulk modulus elasticity is N/m2 (Pa)
The imperial (BG) unit is lbf/in2 (psi)
186
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
1 lbf/in2 (psi) = 6.894 103 N/m2 (Pa)
Bulk Modulus for some common fluids can be found in the table below:
Imperial Units -
SI Units
Bulk Modulus - E BG
(Pa, N/m2) x 109
(psi, lbf/in ) x 10
2 5
Carbon
1.91 1.31
Tetrachloride
Ethyl Alcohol 1.54 1.06
Gasoline 1.9 1.3
Glycerin 6.56 4.52
Mercury 4.14 2.85
SAE 30 Oil 2.2 1.5
Seawater 3.39 2.35
Water 3.12 2.15
C
Capillarity: (or capillary action) The ability of a narrow tube to draw a liquid upwards against the
force of gravity.
where
h = height of liquid (ft, m)
= surface tension (lb/ft, N/m)
= contact angle
= density of liquid (lb/ft3, kg/m3)
g = acceleration due to gravity (32.174 ft/s2, 9.81 m/s2)
r = radius of tube (ft, m)
Cauchy Number: A dimensionless value useful for analyzing fluid flow dynamics problems
where compressibility is a significant factor.
The Cauchy Number is the ratio between inertial and the compressibility force in a flow and can
be expressed as
C = v2 / E (1)
where
= density (kg/m3)
v = flow velocity (m/s)
E = bulk modulus elasticity (N/m2)
The bulk modulus elasticity has the dimension pressure and is commonly used to characterize
the compressibility of a fluid.
187
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The Cauchy Number is the square root of the Mach Number
M2 = Ca (3)
where
C = Mach Number
Cavitation: Under the wrong condition, cavitation will reduce the components life time
dramatically. Cavitation may occur when the local static pressure in a fluid reach a level below
the vapor pressure of the liquid at the actual temperature. According to the Bernoulli Equation this
may happen when the fluid accelerates in a control valve or around a pump impeller. The
vaporization itself does not cause the damage - the damage happens when the vapor almost
immediately collapses after evaporation when the velocity is decreased and pressure increased.
Cavitation means that cavities are forming in the liquid that we are pumping. When these cavities
form at the suction of the pump several things happen all at once: We experience a loss in
capacity. We can no longer build the same head (pressure). The efficiency drops. The cavities or
bubbles will collapse when they pass into the higher regions of pressure causing noise, vibration,
and damage to many of the components. The cavities form for five basic reasons and it is common
practice to lump all of them into the general classification of cavitation.
This is an error because we will learn that to correct each of these conditions we must understand
why they occur and how to fix them. Here they are in no particular order: Vaporization, Air
ingestion, Internal recirculation, Flow turbulence and finally the Vane Passing Syndrome.
Avoiding Cavitation
Cavitation can in general be avoided by:
increasing the distance between the actual local static pressure in the fluid - and the vapor
pressure of the fluid at the actual temperature
This can be done by:
reengineering components initiating high speed velocities and low static pressures
increasing the total or local static pressure in the system
reducing the temperature of the fluid
Reengineering of Components Initiating High Speed Velocity and Low Static Pressure
Cavitation and damage can be avoided by using special components designed for the actual
rough conditions.
Conditions such as huge pressure drops can - with limitations - be handled by Multi Stage
Control Valves
Difficult pumping conditions - with fluid temperatures close to the vaporization temperature -
can be handled with a special pump - working after another principle than the centrifugal
pump.
188
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Cavitation Continued: Increasing the Total or Local Pressure in the System
By increasing the total or local pressure in the system, the distance between the static pressure
and the vaporization pressure is increased and vaporization and cavitation may be avoided.
The ratio between static pressure and the vaporization pressure, an indication of the possibility of
vaporization, is often expressed by the Cavitation Number. Unfortunately it may not always be
possible to increase the total static pressure due to system classifications or other limitations.
Local static pressure in the component may then be increased by lowering the component in the
system. Control valves and pumps should in general be positioned in the lowest part of the system
to maximize the static head. This is common for boiler feeding pumps receiving hot condensate
(water close to 100 oC) from a condensate receiver.
As we can see - the possibility of evaporation and cavitation increases dramatically with the
water temperature.
189
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Cavitation can be avoided by locating the components in the coldest part of the system. For
example, it is common to locate the pumps in heating systems at the "cold" return lines. The
situation is the same for control valves. Where it is possible they should be located on the cold
side of heat exchangers.
The Cavitations Number is useful for analyzing fluid flow dynamics problems where cavitations
may occur. The Cavitations Number can be expressed as
Ca = ( pr - pv ) / 1/2 v2 (1)
where
Ca = Cavitations number
pr = reference pressure
(Pa)
pv = vapor pressure of the
fluid (Pa)
= density of the fluid
(kg/m )3
v = c (R S)1/2 (1)
where
v = mean velocity (m/s, ft/s)
c = the Chezy roughness and conduit coefficient
R = hydraulic radius of the conduit (m, ft)
S = slope of the conduit (m/m, ft/ft)
In general the Chezy coefficient - c - is a function of the flow Reynolds Number - Re - and the
relative roughness - /R - of the channel.
is the characteristic height of the roughness elements on the channel boundary.
190
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Coanda Effect: The tendency of a stream of fluid to stay attached to a convex surface, rather
than follow a straight line in its original direction.
Colebrook Equation: The friction coefficients used to calculate pressure loss (or major loss) in
ducts, tubes and pipes can be calculated with the Colebrook equation.
where
= D'Arcy-Weisbach friction coefficient
Re = Reynolds Number
k = roughness of duct, pipe or tube surface (m, ft)
dh = hydraulic diameter (m, ft)
The Colebrook equation is generic and can be used to calculate the friction coefficients in
different kinds of fluid flows - air ventilation ducts, pipes and tubes with water or oil, compressed
air and much more.
Common Pressure Measuring Devices: The Strain Gauge is a common measuring device used
for a variety of changes such as head. As the pressure in the system changes, the diaphragm
expands which changes the length of the wire attached. This change of length of the wire changes
the Resistance of the wire, which is then converted to head. Float mechanisms, diaphragm
elements, bubbler tubes, and direct electronic sensors are common types of level sensors.
Compressible Flow: We know that fluids are classified as Incompressible and Compressible
fluids. Incompressible fluids do not undergo significant changes in density as they flow. In
general, liquids are incompressible; water being an excellent example. In contrast compressible
fluids do undergo density changes.
Gases are generally compressible; air being the most common compressible fluid we can find.
Compressibility of gases leads to many interesting features such as shocks, which are absent for
incompressible fluids. Gas dynamics is the discipline that studies the flow of compressible fluids
and forms an important branch of Fluid Mechanics. In this book we give a broad introduction to
the basics of compressible fluid flow.
In a compressible flow the compressibility of the fluid must be taken into account. The Ideal Gas
Law - For a perfect or ideal gas the change in density is directly related to the change in
temperature and pressure as expressed in the Ideal Gas Law. Properties of Gas Mixtures -
Special care must be taken for gas mixtures when using the ideal gas law, calculating the mass,
the individual gas constant or the density. The Individual and Universal Gas Constant - The
Individual and Universal Gas Constant is common in fluid mechanics and thermodynamics.
191
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Compression and Expansion of Gases: If the compression or expansion takes place under
constant temperature conditions - the process is called isothermal. The isothermal process can
on the basis of the Ideal Gas Law be expressed as:
p / = constant (1)
where
p = absolute pressure
= density
Conservation Laws: The conservation laws states that particular measurable properties of an
isolated physical system does not change as the system evolves: Conservation of energy
(including mass). Fluid Mechanics and Conservation of Mass - The law of conservation of mass
states that mass can neither be created or destroyed.
Contamination: To make something bad; to pollute or infect something. To reduce the quality
of the potable (drinking) water and create an actual hazard to the water supply by poisoning or
through spread of diseases.
Corrosion: The removal of metal from copper, other metal surfaces and concrete surfaces in a
destructive manner. Corrosion is caused by improperly balanced water or excessive water
velocity through piping or heat exchangers.
Cross-Contamination: The mixing of two unlike qualities of water. For example, the mixing of
good water with a polluting substance like a chemical.
192
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
D
Darcy-Weisbach Equation: The pressure loss (or major loss) in a pipe, tube or duct can be
expressed with the D'Arcy-Weisbach equation:
p = (l / dh) ( v2 / 2) (1)
where
p = pressure loss (Pa, N/m2, lbf/ft2)
= D'Arcy-Weisbach friction coefficient
l = length of duct or pipe (m, ft)
dh = hydraulic diameter (m, ft)
= density (kg/m3, lb/ft3)
Note! Be aware that there are two alternative friction coefficients present in the literature. One is
1/4 of the other and (1) must be multiplied with four to achieve the correct result. This is
important to verify when selecting friction coefficients from Moody diagrams.
Density: Is a physical property of matter, as each element and compound has a unique density
associated with it.
Density defined in a qualitative manner as the measure of the relative "heaviness" of objects
with a constant volume. For example: A rock is obviously more dense than a crumpled piece of
paper of the same size. A Styrofoam cup is less dense than a ceramic cup. Density may also
refer to how closely "packed" or "crowded" the material appears to be - again refer to the
Styrofoam vs. ceramic cup. Take a look at the two boxes below.
Each box has the same volume. If each ball has the same mass, which box would weigh
more? Why?
The box that has more balls has more mass per unit of volume. This property of matter is called
density. The density of a material helps to distinguish it from other materials. Since mass is
usually expressed in grams and volume in cubic centimeters, density is expressed in
grams/cubic centimeter. We can calculate density using the formula:
Density= Mass/Volume
193
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
= m / V = 1 / vg (1)
where
= density (kg/m3)
m = mass (kg)
V = volume (m3)
vg = specific volume (m3/kg)
The SI units for density are kg/m3. The imperial (BG) units are lb/ft3 (slugs/ft3). While people
often use pounds per cubic foot as a measure of density in the U.S., pounds are really a
measure of force, not mass. Slugs are the correct measure of mass. You can multiply slugs by
32.2 for a rough value in pounds. The higher the density, the tighter the particles are packed
inside the substance. Density is a physical property constant at a given temperature and density
can help to identify a substance.
= [18.5 (g) / 1000 (g/kg)] / [23.4 (ml) / 1000 (ml/l) 1000 (l/m3) ]
= 18.5 10-3 (kg) / 23.4 10-6 (m3)
= 790 kg/m3
If we look up densities of some common substances, we can find that ethyl alcohol, or ethanol,
has a density of 790 kg/m3. Our unknown liquid may likely be ethyl alcohol!
Dilatant Fluids: Shear Thickening Fluids or Dilatant Fluids increase their viscosity with
agitation. Some of these liquids can become almost solid within a pump or pipe line. With
agitation, cream becomes butter and Candy compounds, clay slurries and similar heavily filled
liquids do the same thing.
Disinfect: To kill and inhibit growth of harmful bacterial and viruses in drinking water.
Disinfection: The treatment of water to inactivate, destroy, and/or remove pathogenic bacteria,
viruses, protozoa, and other parasites.
194
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
If the vent line on a ground level storage tank is closed or clogged up, a vacuum will develop in
the tank may happen to the tank when the water level begins to lower.
Drag Coefficient: Used to express the drag of an object in moving fluid. Any object moving
through a fluid will experience a drag - the net force in direction of flow due to the pressure and
shear stress forces on the surface of the object.
Fd = cd 1/2 v2 A (1)
where
Fd = drag force (N)
cd = drag coefficient
= density of fluid
v = flow velocity
A = characteristic frontal area of the body
The drag coefficient is a function of several parameters as shape of the body, Reynolds Number
for the flow, Froude number, Mach Number and Roughness of the Surface.
The characteristic frontal area - A - depends on the body.
Dynamic or Absolute Viscosity: The viscosity of a fluid is an important property in the analysis
of liquid behavior and fluid motion near solid boundaries. The viscosity of a fluid is its resistance
to shear or flow and is a measure of the adhesive/cohesive or frictional properties of a fluid. The
resistance is caused by intermolecular friction exerted when layers of fluids attempts to slide by
another.
Dynamic Pressure: Dynamic pressure is the component of fluid pressure that represents a
fluids kinetic energy. The dynamic pressure is a defined property of a moving flow of gas or
liquid and can be expressed as
pd = 1/2 v2 (1)
where
pd = dynamic pressure (Pa)
= density of fluid (kg/m3)
v = velocity (m/s)
Dynamic, Absolute and Kinematic Viscosity: The viscosity of a fluid is an important property
in the analysis of liquid behavior and fluid motion near solid boundaries. The viscosity is the fluid
resistance to shear or flow and is a measure of the adhesive/cohesive or frictional fluid property.
The resistance is caused by intermolecular friction exerted when layers of fluids attempts to slide
by another.
The knowledge of viscosity is needed for proper design of required temperatures for storage,
pumping or injection of fluids.
195
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Common used units for viscosity are
CentiPoises (cp) = CentiStokes (cSt) Density
SSU1 = Centistokes (cSt) 4.55
Degree Engler1 7.45 = Centistokes (cSt)
Seconds Redwood1 0.2469 = Centistokes (cSt)
1centistokes greater than 50
There are two related measures of fluid viscosity - known as dynamic (or absolute) and
kinematic viscosity.
Dynamic (absolute) Viscosity: The tangential force per unit area required to move one
horizontal plane with respect to the other at unit velocity when maintained a unit distance apart
by the fluid. The shearing stress between the layers of non-turbulent fluid moving in straight
parallel lines can be defined for a Newtonian fluid as:
= dc/dy (1)
where
= shearing stress
= dynamic viscosity
In the SI system the dynamic viscosity units are N s/m2, Pa s or kg/m s where
1 Pa s = 1 N s/m2 = 1 kg/m s
The dynamic viscosity is also often expressed in the metric CGS (centimeter-gram-second)
system as g/cm.s, dyne.s/cm2 or poise (p) where
1 poise = dyne s/cm2 = g/cm s = 1/10 Pa s
For practical use the Poise is to large and its usual divided by 100 into the smaller unit called
the centiPoise (cP) where
1 p = 100 cP
E
E. Coli, Escherichia coli: A bacterium commonly found in the human intestine. For water
quality analyses purposes, it is considered an indicator organism. These are considered
evidence of water contamination. Indicator organisms may be accompanied by pathogens, but
do not necessarily cause disease themselves.
Elevation Head: The energy possessed per unit weight of a fluid because of its elevation. 1
foot of water will produce .433 pounds of pressure head.
Energy: The ability to do work. Energy can exist in one of several forms, such as heat, light,
mechanical, electrical, or chemical. Energy can be transferred to different forms. It also can
exist in one of two states, either potential or kinetic.
196
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Energy and Hydraulic Grade Line: The hydraulic grade and the energy line are graphical
forms of the Bernoulli equation. For steady, in viscid, incompressible flow the total energy
remains constant along a stream line as expressed through the Bernoulli
Equation:
p + 1/2 v2 + h = constant along a streamline (1)
where
p = static pressure (relative to the moving fluid)
= density
= specific weight
v = flow velocity
g = acceleration of gravity
h = elevation height
Each term of this equation has the dimension force per unit area - psi, lb/ft2 or N/m2.
The Head
By dividing each term with the specific weight - = g - (1) can be transformed to express the
"head":
p / + v2 / 2 g + h = constant along a streamline = H (2)
where
H = the total head
The total head in a flow can be measured by the stagnation pressure using a pitot tube.
where
EL = Energy Line
For a fluid flow without any losses due to friction (major losses) or components (minor losses)
the energy line would be at a constant level. In the practical world the energy line decreases
along the flow due to the losses.
197
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A turbine in the flow will reduce the energy line and a pump or fan will increase the energy line.
HGL = p / + h (4)
where
HGL = Hydraulic Grade Line
The hydraulic grade line lies one velocity head below the energy line.
Entrance Length and Developed Flow: Fluids need some length to develop the velocity profile
after entering the pipe or after passing through components such as bends, valves, pumps, and
turbines or similar.
The Entrance Length: The entrance length can be expressed with the dimensionless Entrance
Length Number:
El = le / d (1)
where
El = Entrance Length Number
le = length to fully developed velocity profile
d = tube or duct diameter
where
Re = Reynolds Number
198
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
where
ds = entropy change
cv = specific heat capacity at a constant volume process
cp = specific heat capacity at a constant pressure process
T = absolute temperature
R = individual gas constant
= density of gas
p = absolute pressure
Equation of Continuity: The Law of Conservation of Mass states that mass can be neither
created nor destroyed. Using the Mass Conservation Law on a steady flow process - flow
where the flow rate doesn't change over time - through a control volume where the stored mass
in the control volume doesn't change - implements that inflow equals outflow. This statement is
called the Equation of Continuity. Common application where the Equation of Continuity
can be used are pipes, tubes and ducts with flowing fluids and gases, rivers, overall processes
as power plants, diaries, logistics in general, roads, computer networks and semiconductor
technology and more.
where
m = mass flow rate (kg/s)
= density (kg/m3)
v = speed (m/s)
A = area (m2)
With uniform density equation (1) can be modified to
q = vi1 Ai1 + vi2 Ai2 +..+ vin Aim
= vo1 Ao1 + vo2 Ao2 +..+ vom Aom (2)
where
q = flow rate (m3/s)
i1 = i2 = . . = in = o1 = o2 = . .= om
199
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Equation of Mechanical Energy: The Energy Equation is a statement of the first law of
thermodynamics. The energy equation involves energy, heat transfer and work. With certain
limitations the mechanical energy equation can be compared to the Bernoulli Equation and
transferred to the Mechanical Energy Equation in Terms of Energy per Unit Mass.
The mechanical energy equation for a pump or a fan can be written in terms of energy per
unit mass:
where
p = static pressure
= density
v = flow velocity
g = acceleration of gravity
h = elevation height
wshaft = net shaft energy inn per unit mass for a pump, fan or similar
wloss = loss due to friction
The energy equation is often used for incompressible flow problems and is called the
Mechanical Energy Equation or the Extended Bernoulli Equation.
where
wshaft = net shaft energy out per unit mass for a turbine or similar
Efficiency
According to (1) a larger amount of loss - wloss - result in more shaft work required for the same
rise of output energy. The efficiency of a pump or fan process can be expressed as:
where
= g = specific weight
200
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The dimensions of equation (5) are
energy per unit volume (ft.lb/ft3 = lb/ft2 or N.m/m3 = N/m2)
The Mechanical Energy Equation in Terms of Energy per Unit Weight involves Heads
The mechanical energy equation for a pump or a fan (1) can also be written in terms of energy
per unit weight by dividing with gravity - g:
where
= g = specific weight
hshaft = wshaft / g = net shaft energy head inn per unit mass for a pump, fan or similar
hloss = wloss / g = loss head due to friction
where
Wshaft = shaft power
m = mass flow rate
Q = volume flow rate
The pump efficiency can be calculated from (3) modified for head:
= ((17.6 ft) - (7.6 ft)) / (17.6 ft)= 0.58
201
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Equations in Fluid Mechanics: Common fluid mechanics equations - Bernoulli, conservation
of energy, conservation of mass, pressure, Navier-Stokes, ideal gas law, Euler equations,
Laplace equations, Darcy-Weisbach Equation and the following:
The Bernoulli Equation
The Bernoulli Equation - A statement of the conservation of energy in a form useful for
solving problems involving fluids. For a non-viscous, incompressible fluid in steady flow, the
sum of pressure, potential and kinetic energies per unit volume is constant at any point.
Conservation laws
The conservation laws states that particular measurable properties of an isolated physical
system does not change as the system evolves.
Conservation of energy (including mass)
Fluid Mechanics and Conservation of Mass - The law of conservation of mass states that
mass can neither be created nor destroyed.
The Continuity Equation - The Continuity Equation is a statement that mass is conserved.
Darcy-Weisbach Equation
Pressure Loss and Head Loss due to Friction in Ducts and Tubes - Major loss - head loss or
pressure loss - due to friction in pipes and ducts.
Euler Equations
In fluid dynamics, the Euler equations govern the motion of a compressible, inviscid fluid.
They correspond to the Navier-Stokes equations with zero viscosity, although they are
usually written in the form shown here because this emphasizes the fact that they directly
represent conservation of mass, momentum, and energy.
Laplace's Equation
The Laplace Equation describes the behavior of gravitational, electric, and fluid potentials.
Ideal Gas Law
The Ideal Gas Law - For a perfect or ideal gas, the change in density is directly related to
the change in temperature and pressure as expressed in the Ideal Gas Law.
Properties of Gas Mixtures - Special care must be taken for gas mixtures when using the
ideal gas law, calculating the mass, the individual gas constant or the density.
The Individual and Universal Gas Constant - The Individual and Universal Gas Constant is
common in fluid mechanics and thermodynamics.
Navier-Stokes Equations
The motion of a non-turbulent, Newtonian fluid is governed by the Navier-Stokes equations.
The equation can be used to model turbulent flow, where the fluid parameters are
interpreted as time-averaged values.
Mechanical Energy Equation
The Mechanical Energy Equation - The mechanical energy equation in Terms of Energy per
Unit Mass, in Terms of Energy per Unit Volume and in Terms of Energy per Unit Weight
involves Heads.
Pressure
Static Pressure and Pressure Head in a Fluid - Pressure and pressure head in a static fluid.
202
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Euler Equations: In fluid dynamics, the Euler equations govern the motion of a compressible,
inviscid fluid. They correspond to the Navier-Stokes equations with zero viscosity, although they
are usually written in the form shown here because this emphasizes the fact that they directly
represent conservation of mass, momentum, and energy.
Euler Number: The Euler numbers, also called the secant numbers or zig numbers, are defined
for by
where the hyperbolic secant and sec is the secant. Euler numbers give the number of
odd alternating permutations and are related to Genocchi numbers. The base e of the natural
logarithm is sometimes known as Euler's number. A different sort of Euler number, the Euler
number of a finite complex , is defined by
This Euler number is a topological invariant. To confuse matters further, the Euler characteristic
is sometimes also called the "Euler number," and numbers produced by the prime-generating
polynomial are sometimes called "Euler numbers" (Flannery and Flannery 2000, p.
47).
F
Fecal Coliform: A group of bacteria that may indicate the presence of human or animal fecal
matter in water.
Flood Rim: The point of an object where the water would run over the edge of something and
begin to cause a flood. See Air Break.
Fluids: A fluid is defined as a substance that continually deforms (flows) under an applied shear
stress regardless of the magnitude of the applied stress. It is a subset of the phases of matter and
includes liquids, gases, plasmas and, to some extent, plastic solids. Fluids are also divided into
liquids and gases. Liquids form a free surface (that is, a surface not created by their container)
while gases do not.
The distinction between solids and fluids is not so obvious. The distinction is made by evaluating
the viscosity of the matter: for example silly putty can be considered either a solid or a fluid,
depending on the time period over which it is observed. Fluids share the properties of not resisting
deformation and the ability to flow (also described as their ability to take on the shape of their
containers).
These properties are typically a function of their inability to support a shear stress in static
equilibrium. While in a solid, stress is a function of strain, in a fluid, stress is a function of rate of
203
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
strain. A consequence of this behavior is Pascal's law which entails the important role of pressure
in characterizing a fluid's state. Based on how the stress depends on the rate of strain and its
derivatives, fluids can be characterized as: Newtonian fluids: where stress is directly proportional
to rate of strain, and Non-Newtonian fluids : where stress is proportional to rate of strain, its higher
powers and derivatives (basically everything other than Newtonian fluid).
The behavior of fluids can be described by a set of partial differential equations, which are based
on the conservation of mass, linear and angular momentum (Navier-Stokes equations) and
energy. The study of fluids is fluid mechanics, which is subdivided into fluid dynamics and fluid
statics depending on whether the fluid is in motion or not. Fluid Related Information: The
Bernoulli Equation - A statement of the conservation of energy in a form useful for solving
problems involving fluids. For a non-viscous, incompressible fluid in steady flow, the sum of
pressure, potential and kinetic energies per unit volume is constant at any point. Equations in
Fluid Mechanics - Continuity, Euler, Bernoulli, Dynamic and Total Pressure. Laminar, Transitional
or Turbulent Flow? - It is important to know if the fluid flow is laminar, transitional or turbulent
when calculating heat transfer or pressure and head loss.
Friction Head: The head required to overcome the friction at the interior surface of a conductor
and between fluid particles in motion. It varies with flow, size, type and conditions of conductors
and fittings, and the fluid characteristics.
G
Gas: A gas is one of the four major phases of matter (after solid and liquid, and followed by
plasma) that subsequently appear as solid material when they are subjected to increasingly higher
temperatures. Thus, as energy in the form of heat is added, a solid (e.g., ice) will first melt to
become a liquid (e.g., water), which will then boil or evaporate to become a gas (e.g., water vapor).
In some circumstances, a solid (e.g., "dry ice") can directly turn into a gas: this is called
sublimation. If the gas is further heated, its atoms or molecules can become (wholly or partially)
ionized, turning the gas into a plasma. Relater Gas Information: The Ideal Gas Law - For a perfect
or ideal gas the change in density is directly related to the change in temperature and pressure
as expressed in the Ideal Gas Law. Properties of Gas Mixtures - Special care must be taken for
gas mixtures when using the ideal gas law, calculating the mass, the individual gas constant or
the density. The Individual and Universal Gas Constant - The Individual and Universal Gas
Constant is common in fluid mechanics and thermodynamics.
H
Hazardous Atmosphere: An atmosphere which by reason of being explosive, flammable,
poisonous, corrosive, oxidizing, irritating, oxygen deficient, toxic, or otherwise harmful, may
cause death, illness, or injury.
Hazen-Williams Factor: Hazen-Williams factor for some common piping materials. Hazen-
Williams coefficients are used in the Hazen-Williams equation for friction loss calculation in
ducts and pipes.
204
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Hazen-Williams Equation - Calculating Friction Head Loss in Water Pipes
Friction head loss (ft H2O per 100 ft pipe) in water pipes can be obtained by using the empirical
Hazen-Williams equation. The Darcy-Weisbach equation with the Moody diagram are considered
to be the most accurate model for estimating frictional head loss in steady pipe flow. Since the
approach requires a not so efficient trial and error solution, an alternative empirical head loss
calculation that does not require the trial and error solutions, as the Hazen-Williams equation,
may be preferred:
where
f = friction head loss in feet of water per 100 feet of pipe (fth20/100 ft pipe)
c = Hazen-Williams roughness constant
q = volume flow (gal/min)
dh = inside hydraulic diameter (inches)
Note that the Hazen-Williams formula is empirical and lacks physical basis. Be aware that the
roughness constants are based on "normal" condition with approximately 1 m/s (3 ft/sec).
The Hazen-Williams formula is not the only empirical formula available. Manning's formula is
common for gravity driven flows in open channels.
v = 0.4087 q / dh2
where
v = flow velocity (ft/s)
The Hazen-Williams formula can be assumed to be relatively accurate for piping systems where
the Reynolds Number is above 105 (turbulent flow).
1 ft (foot) = 0.3048 m
1 in (inch) = 25.4 mm
1 gal (US)/min =6.30888x10-5 m3/s = 0.0227 m3/h = 0.0631 dm3(liter)/s = 2.228x10-3 ft3/s =
0.1337 ft3/min = 0.8327 Imperial gal (UK)/min
Note! The Hazen-Williams formula gives accurate head loss due to friction for fluids with
kinematic viscosity of approximately 1.1 cSt. More about fluids and kinematic viscosity.
The results for the formula are acceptable for cold water at 60o F (15.6o C) with kinematic viscosity
1.13 cSt. For hot water with a lower kinematic viscosity (0.55 cSt at 130o F (54.4o C)) the error will
be significant. Since the Hazen Williams method is only valid for water flowing at ordinary
temperatures between 40 to 75o F, the Darcy Weisbach method should be used for other liquids
or gases.
Head: The height of a column or body of fluid above a given point expressed in linear units. Head
if often used to indicate gauge pressure. Pressure is equal to the height times the density of the
liquid. The measure of the pressure of water expressed in feet of height of water. 1 psi = 2.31 feet
205
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
of water. There are various types of heads of water depending upon what is being measured. Static
(water at rest) and Residual (water at flow conditions).
Hydraulics: Hydraulics is a branch of science and engineering concerned with the use of
liquids to perform mechanical tasks.
I
Ideal Gas: The Ideal Gas Law - For a perfect or ideal gas the change in density is directly related
to the change in temperature and pressure as expressed in the Ideal Gas Law. Properties of Gas
Mixtures - Special care must be taken for gas mixtures when using the ideal gas law, calculating
the mass, the individual gas constant or the density. The Individual and Universal Gas Constant
- The Individual and Universal Gas Constant is common in fluid mechanics and thermodynamics.
p / k = constant (2)
where
k = cp / cv - the ratio of specific heats - the ratio of specific heat at constant pressure - cp -
to the specific heat at constant volume - cv
Irrigation: Water that is especially furnished to help provide and sustain the life of growing plants.
It comes from ditches. It is sometimes treated with herbicides and pesticides to prevent the growth
of weeds and the development of bugs in a lawn and a garden.
K
Kinematic Viscosity: The ratio of absolute or dynamic viscosity to density - a quantity in which
no force is involved. Kinematic viscosity can be obtained by dividing the absolute viscosity of a
fluid with its mass density as
=/ (2)
where
= kinematic viscosity
= absolute or dynamic viscosity
= density
In the SI-system the theoretical unit is m2/s or commonly used Stoke (St) where
1 St = 10-4 m2/s
Since the Stoke is an unpractical large unit, it is usual divided by 100 to give the unit called
Centistokes (cSt) where
1 St = 100 cSt
206
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
1 cSt = 10-6 m2/s
Since the specific gravity of water at 68.4oF (20.2oC) is almost one - 1, the kinematic viscosity of
water at 68.4oF is for all practical purposes 1.0 cSt.
Kinetic Energy: The ability of an object to do work by virtue of its motion. The energy terms that
are used to describe the operation of a pump are pressure and head.
L
Laminar Flow: The resistance to flow in a liquid can be characterized in terms of the viscosity of
the fluid if the flow is smooth. In the case of a moving plate in a liquid, it is found that there is a
layer or lamina which moves with the plate, and a layer which is essentially stationary if it is next
to a stationary plate. There is a gradient of velocity as you move from the stationary to the moving
plate, and the liquid tends to move in layers with successively higher speed. This is called laminar
flow, or sometimes "streamlined" flow. Viscous resistance to flow can be modeled for laminar flow,
but if the lamina break up into turbulence, it is very difficult to characterize the fluid flow.
The common application of laminar flow would be in the smooth flow of a viscous liquid through
a tube or pipe. In that case, the velocity of flow varies from zero at the walls to a maximum along
the centerline of the vessel. The flow profile of laminar flow in a tube can be calculated by dividing
the flow into thin cylindrical elements and applying the viscous force to them. Laminar, Transitional
or Turbulent Flow? - It is important to know if the fluid flow is laminar, transitional or turbulent
when calculating heat transfer or pressure and head loss.
207
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Laplace's Equation: Describes the behavior of gravitational, electric, and fluid potentials.
Lift (Force): Lift consists of the sum of all the aerodynamic forces normal to the direction of the
external airflow.
Liquids: An in-between state of matter. They can be found in between the solid and gas states.
They don't have to be made up of the same compounds. If you have a variety of materials in a
liquid, it is called a solution. One characteristic of a liquid is that it will fill up the shape of a
container. If you pour some water in a cup, it will fill up the bottom of the cup first and then fill
the rest. The water will also take the shape of the cup. It fills the bottom first because of gravity.
The top part of a liquid will usually have a flat surface. That flat surface is because of gravity too.
Putting an ice cube (solid) into a cup will leave you with a cube in the middle of the cup; the
shape won't change until the ice becomes a
liquid.
208
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A special force keeps liquids together. Solids are stuck together and you have to force them
apart. Gases bounce everywhere and they try to spread themselves out. Liquids actually want
to stick together. There will always be the occasional evaporation where extra energy gets a
molecule excited and the molecule leaves the system. Overall, liquids have cohesive (sticky)
forces at work that hold the molecules together. Related Liquid Information: Equations in Fluid
Mechanics - Continuity, Euler, Bernoulli, Dynamic and Total Pressure
M
Mach Number: When an object travels through a medium, then its Mach number is the ratio of
the object's speed to the speed of sound in that medium.
Magnetic Flow Meter: Inspection of magnetic flow meter instrumentation should include
checking for corrosion or insulation deterioration.
Manning Formula for Gravity Flow: Manning's equation can be used to calculate cross-
sectional average velocity flow in open channels
where
v = cross-sectional average velocity (ft/s, m/s)
kn = 1.486 for English units and kn = 1.0 for SI units
A = cross sectional area of flow (ft2, m2)
n = Manning coefficient of roughness
R = hydraulic radius (ft, m)
S = slope of pipe (ft/ft, m/m)
where
q = volume flow (ft3/s, m3/s)
A = cross-sectional area of flow (ft2, m2)
Mechanical Seal: A mechanical device used to control leakage from the stuffing box of a pump.
Usually made of two flat surfaces, one of which rotates on the shaft. The two flat surfaces are of
such tolerances as to prevent the passage of water between them.
Microbe, Microbial: Any minute, simple, single-celled form of life, especially one that causes
disease.
209
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Microbial Contaminants: Microscopic organisms present in untreated water that can cause
waterborne diseases.
ML: milliliter
N
Navier-Stokes Equations: The motion of a non-turbulent, Newtonian fluid is governed by the
Navier-Stokes equation. The equation can be used to model turbulent flow, where the fluid
parameters are interpreted as time-averaged values.
Newtonian Fluid: Newtonian fluid (named for Isaac Newton) is a fluid that flows like waterits
shear stress is linearly proportional to the velocity gradient in the direction perpendicular to the
plane of shear. The constant of proportionality is known as the viscosity. Water is Newtonian,
because it continues to exemplify fluid properties no matter how fast it is stirred or mixed.
Contrast this with a non-Newtonian fluid, in which stirring can leave a "hole" behind (that gradually
fills up over time - this behavior is seen in materials such as pudding, or to a less rigorous extent,
sand), or cause the fluid to become thinner, the drop in viscosity causing it to flow more (this is
seen in non-drip paints). For a Newtonian fluid, the viscosity, by definition, depends only on
temperature and pressure (and also the chemical composition of the fluid if the fluid is not a pure
substance), not on the forces acting upon it. If the fluid is incompressible and viscosity is constant
across the fluid, the equation governing the shear stress. Related Newtonian Information: A Fluid
is Newtonian if viscosity is constant applied to shear force. Dynamic, Absolute and Kinematic
Viscosity - An introduction to dynamic, absolute and kinematic viscosity and how to convert
between CentiStokes (cSt), CentiPoises (cP), Saybolt Universal Seconds (SSU) and degree
Engler.
Newton's Third Law: Newton's third law describes the forces acting on objects interacting with
each other. Newton's third law can be expressed as
"If one object exerts a force F on another object, then the second object exerts an equal but
opposite force F on the first object"
Force is a convenient abstraction to represent mentally the pushing and pulling interaction
between objects.
It is common to express forces as vectors with magnitude, direction and point of application.
The net effect of two or more forces acting on the same point is the vector sum of the forces.
Non-Newtonian Fluid: Non-Newtonian fluid viscosity changes with the applied shear force.
O
Oxidizing: The process of breaking down organic wastes into simpler elemental forms or by
products. Also used to separate combined chlorine and convert it into free chlorine.
210
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
P
Pascals Law: A pressure applied to a confined fluid at rest is transmitted with equal intensity
throughout the fluid.
pH: A measure of the acidity of water. The pH scale runs from 0 to 14 with 7 being the mid-point
or neutral. A pH of less than 7 is on the acid side of the scale with 0 as the point of greatest acid
activity. A pH of more than 7 is on the basic (alkaline) side of the scale with 14 as the point of
greatest basic activity. pH (Power of Hydroxyl Ion Activity).
Pipeline Appurtenances: Pressure reducers, bends, valves, regulators (which are a type of
valve), etc.
Peak Demand: The maximum momentary load placed on a water treatment plant, pumping
station or distribution system is the Peak Demand.
Imperial units
A fluids flow velocity in pipes can be calculated with Imperial or American units as
v = 0.4085 q / d2 (1)
where
v = velocity (ft/s)
q = volume flow (US gal. /min)
d = pipe inside diameter (inches)
SI units
A fluids flow velocity in pipes can be calculated with SI units as
v = 1.274 q / d2 (2)
where
v = velocity (m/s)
q = volume flow (m3/s)
d = pipe inside diameter (m)
Pollution: To make something unclean or impure. Some states will have a definition of pollution
that relates to non-health related water problems, like taste and odors. See Contaminated.
Positive Flow Report-back Signal: When a pump receives a signal to start, a light will typically
be illuminated on the control panel indicating that the pump is running. In order to be sure that
the pump is actually pumping water, a Positive flow report-back signal should be installed on the
control panel.
211
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Potable: Good water which is safe for drinking or cooking purposes. Non-Potable: A liquid or
water that is not approved for drinking.
Potential Energy: The energy that a body has by virtue of its position or state enabling it to do
work.
Prandtl Number: The Prandtl Number is a dimensionless number approximating the ratio of
momentum diffusivity and thermal diffusivity and can be expressed as
Pr = v / (1)
where
Pr = Prandtl's number
v = kinematic viscosity (Pa s)
= thermal diffusivity (W/m K)
Pr = cp / k (2)
where
= absolute or dynamic viscosity (kg/m s, cP)
cp = specific heat capacity (J/kg K, Btu/(lb oF))
k = thermal conductivity (W/m K, Btu/(h ft2 oF/ft))
The Prandtl Number is often used in heat transfer and free and forced convection calculations.
Pressure: An introduction to pressure - the definition and presentation of common units as psi
and Pa and the relationship between them.
where
p = pressure [lb/in2 (psi) or lb/ft2 (psf), N/m2 or kg/ms2 (Pa)]
F = force [1), N]
A = area [in2 or ft2, m2]
1) In the English Engineering System special care must be taken for the force unit. The basic
unit for mass is the pound mass (lbm) and the unit for the force is the pound (lb) or pound force
(lbf).
Absolute Pressure
The absolute pressure - pa - is measured relative to the absolute zero pressure - the pressure
that would occur at absolute vacuum.
212
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Gauge Pressure
A gauge is often used to measure the pressure difference between a system and the
surrounding atmosphere. This pressure is often called the gauge pressure and can be
expressed as
pg = pa - po (2)
where
pg = gauge pressure
po = atmospheric pressure
Atmospheric Pressure
The atmospheric pressure is the pressure in the surrounding air. It varies with temperature and
altitude above sea level.
Pressure Head: The height to which liquid can be raised by a given pressure.
Pressure Regulation Valves: Control water pressure and operate by restricting flows. They are
used to deliver water from a high pressure to a low-pressure system. The pressure downstream
from the valve regulates the amount of flow. Usually, these valves are of the globe design and
have a spring-loaded diaphragm that sets the size of the opening.
Pressure Units: Since 1 Pa is a small pressure unit, the unit hectopascal (hPa) is widely used,
especially in meteorology. The unit kilopascal (kPa) is commonly used designing technical
applications like HVAC systems, piping systems and similar.
1 hectopascal = 100 pascal = 1 millibar
1 kilopascal = 1000 pascal
Some Pressure Levels
10 Pa - The pressure at a depth of 1 mm of water
1 kPa - Approximately the pressure exerted by a 10 g mass on a 1 cm2 area
10 kPa - The pressure at a depth of 1 m of water, or
the drop in air pressure when going from sea level to 1000 m elevation
10 MPa - A "high pressure" washer forces the water out of the nozzles at this pressure
10 GPa - This pressure forms diamonds
Some Alternative Units of Pressure
1 bar - 100,000 Pa
1 millibar - 100 Pa
1 atmosphere - 101,325 Pa
1 mm Hg - 133 Pa
1 inch Hg - 3,386 Pa
213
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
A torr (torr) is named after Torricelli and is the pressure produced by a column of mercury 1 mm
high equals to 1/760th of an atmosphere. 1 atm = 760 torr = 14.696 psi
Pounds per square inch (psi) was common in U.K. but has now been replaced in almost every
country except in the U.S. by the SI units. The Normal atmospheric pressure is 14.696 psi,
meaning that a column of air on one square inch in area rising from the Earth's atmosphere to
space weighs 14.696 pounds.
The bar (bar) is common in the industry. One bar is 100,000 Pa, and for most practical
purposes can be approximated to one atmosphere even if
1 Bar = 0.9869 atm
There are 1,000 millibar (mbar) in one bar, a unit common in meteorology.
1 millibar = 0.001 bar = 0.750 torr = 100 Pa
R
Residual Disinfection/Protection: A required level of disinfectant that remains in treated water
to ensure disinfection protection and prevent recontamination throughout the distribution system
(i.e., pipes).
Reynolds Number: The Reynolds number is used to determine whether a flow is laminar or
turbulent. The Reynolds Number is a non-dimensional parameter defined by the ratio of
dynamic pressure ( u2) and shearing stress ( u / L) - and can be expressed as
Re = ( u2) / ( u / L)
=uL/
= u L / (1)
where
Re = Reynolds Number (non-dimensional)
= density (kg/m3, lbm/ft3 )
u = velocity (m/s, ft/s)
= dynamic viscosity (Ns/m2, lbm/s ft)
L = characteristic length (m, ft)
= kinematic viscosity (m2/s, ft2/s)
Richardson Number: A dimensionless number that expresses the ratio of potential to kinetic
energy.
S
Sanitizer: A chemical which disinfects (kills bacteria), kills algae and oxidizes organic matter.
Saybolt Universal Seconds (or SUS, SSU): Saybolt Universal Seconds (or SUS) is used to
measure viscosity. The efflux time is Saybolt Universal Seconds (SUS) required for 60 milliliters
of a petroleum product to flow through the calibrated orifice of a Saybolt Universal viscometer,
under carefully controlled temperature and as prescribed by test method ASTM D 88. This
method has largely been replaced by the kinematic viscosity method. Saybolt Universal
214
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Seconds is also called the SSU number (Seconds Saybolt Universal) or SSF number (Saybolt
Seconds Furol).
= 4.63 / SG (3)
where
= kinematic viscosity (SSU)
= dynamic or absolute viscosity (cP)
Scale: Crust of calcium carbonate, the result of unbalanced pool water. Hard insoluble minerals
deposited (usually calcium bicarbonate) which forms on pool and spa surfaces and clog filters,
heaters and pumps. Scale is caused by high calcium hardness and/or high pH. You will often find
major scale deposits inside a backflow prevention assembly.
Shock: Also known as superchlorination or break point chlorination. Ridding a pool of organic
waste through oxidization by the addition of significant quantities of a halogen.
Shock Wave: A shock wave is a strong pressure wave produced by explosions or other
phenomena that create violent changes in pressure.
Solder: A fusible alloy used to join metallic parts. Solder for potable water pipes shall be lead-
free.
Sound Barrier: The sound barrier is the apparent physical boundary stopping large objects
from becoming supersonic.
Specific Gravity: The Specific Gravity - SG - is a dimensionless unit defined as the ratio of
density of the material to the density of water at a specified temperature. Specific Gravity can be
expressed as
SG = = / H2O (3)
where
SG = specific gravity
= density of fluid or substance (kg/m3)
H2O = density of water (kg/m3)
It is common to use the density of water at 4o C (39oF) as a reference - at this point the density
of water is at the highest. Since Specific Weight is dimensionless it has the same value in the
metric SI system as in the imperial English system (BG). At the reference point the Specific
Gravity has same numerically value as density.
215
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Specific Weight: Specific Weight is defined as weight per unit volume. Weight is a force.
Mass and Weight - the difference! - What is weight and what is mass? An explanation of the
difference between weight and mass.
Specific Weight can be expressed as
= g (2)
where
= specific weight (kN/m3)
g = acceleration of gravity (m/s2)
The SI-units of specific weight are kN/m3. The imperial units are lb/ft3. The local acceleration g is
under normal conditions 9.807 m/s2 in SI-units and 32.174 ft/s2 in imperial units.
Static Head: The height of a column or body of fluid above a given point
Static Pressure and Pressure Head in Fluids: The pressure indicates the normal force per
unit area at a given point acting on a given plane. Since there is no shearing stresses present in
a fluid at rest - the pressure in a fluid is independent of direction.
For fluids - liquids or gases - at rest the pressure gradient in the vertical direction depends only
on the specific weight of the fluid.
How pressure changes with elevation can be expressed as
dp = - dz (1)
where
dp = change in pressure
dz = change in height
= specific weight
216
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
The pressure gradient in vertical direction is negative - the pressure decrease upwards.
where
= specific weight
g = acceleration of gravity
In general the specific weight - - is constant for fluids. For gases the specific weight - - varies
with the elevation.
where
p2 = pressure at level 2
p1 = pressure at level 1
z2 = level 2
z1 = level 1
(3) can be transformed to:
p1 - p2 = (z2 - z1) (4)
or
p1 - p2 = h (5)
where
h = z2 - z1 difference in elevation - the depth down from location z2.
or
p1 = h + p2 (6)
Streamline - Stream Function: A streamline is the path that an imaginary particle would follow
if it was embedded in the flow.
217
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Strouhal Number: A quantity describing oscillating flow mechanisms. The Strouhal Number is a
dimensionless value useful for analyzing oscillating, unsteady fluid flow dynamics problems.
where
St = Strouhal Number
= oscillation frequency
l = characteristic length
v = flow velocity
The Strouhal Number represents a measure of the ratio of inertial forces due to the unsteadiness
of the flow or local acceleration to the inertial forces due to changes in velocity from one point to
another in the flow field.
The vortices observed behind a stone in a river, or measured behind the obstruction in a vortex
flow meter, illustrate these principles.
Stuffing Box: That portion of the pump which houses the packing or mechanical seal.
Supersonic Flow: Flow with speed above the speed of sound, 1,225 km/h at sea level, is said
to be supersonic.
Surface Tension: Surface tension is a force within the surface layer of a liquid that causes the
layer to behave as an elastic sheet. The cohesive forces between liquid molecules are
responsible for the phenomenon known as surface tension. The molecules at the surface do not
have other like molecules on all sides of them and consequently they cohere more strongly to
those directly associated with them on the surface. This forms a surface "film" which makes it
more difficult to move an object through the surface than to move it when it is completely
submersed. Surface tension is typically measured in dynes/cm, the force in dynes required to
break a film of length 1 cm. Equivalently, it can be stated as surface energy in ergs per square
centimeter. Water at 20C has a surface tension of 72.8 dynes/cm compared to 22.3 for ethyl
alcohol and 465 for mercury.
218
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Surface tension is the energy required to stretch a unit change of a surface area. Surface
tension will form a drop of liquid to a sphere since the sphere offers the smallest area for a
definite volume.
= Fs / l (1)
where
= surface tension (N/m)
Fs = stretching force (N)
l = unit length (m)
Alternative Units
Alternatively, surface tension is typically measured in dynes/cm, which is
the force in dynes required to break a film of length 1 cm
or as surface energy J/m2 or alternatively ergs per square centimeter.
1 dynes/cm = 0.001 N/m = 0.0000685 lbf/ft = 0.571 10-5 lbf/in = 0.0022 poundal/ft = 0.00018
poundal/in = 1.0 mN/m = 0.001 J/m2 = 1.0 erg/cm2 = 0.00010197 kgf/m
Water surface tension at different temperatures can be taken from the table below:
Surface Tension
Temperature
--
(oC)
(N/m)
0 0.0757
10 0.0742
20 0.0728
30 0.0712
40 0.0696
50 0.0679
60 0.0662
70 0.0644
80 0.0626
90 0.0608
100 0.0588
219
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
glycerol : 0.064 (N/m)
mercury : 0.425 (N/m)
methanol : 0.0227 (N/m)
propanol : 0.0237 (N/m)
toluene : 0.0284 (N/m)
water at 20oC : 0.0729 (N/m)
Surge Tanks: Surge tanks can be used to control Water Hammer. A limitation of hydropneumatic
tanks is that they do not provide much storage to meet peak demands during power outages and
you have very limited time to do repairs on equipment.
T
Telemetering Systems: The following are common pressure sensing devices: Helical Sensor,
Bourdon Tube, and Bellows Sensor. The most frequent problem that affects a liquid pressure-
sensing device is air accumulation at the sensor. A diaphragm element being used as a level
sensor would be used in conjunction with a pressure sensor. Devices must often transmit more
than one signal. You can use several types of systems including: Polling, Scanning and
Multiplexing. Transmitting equipment requires installation where temperature will not exceed 130
degrees F.
Thixotropic Fluids: Shear Thinning Fluids or Thixotropic Fluids reduce their viscosity as
agitation or pressure is increased at a constant temperature. Ketchup and mayonnaise are
examples of thixotropic materials. They appear thick or viscous but are possible to pump quite
easily.
Transonic: Flow with speed at velocities just below and above the speed of sound is said to be
transonic.
U
U-Tube Manometer: Pressure measuring devices using liquid columns in vertical or inclined
tubes are called manometers. One of the most common is the water filled u-tube manometer
used to measure pressure difference in pitot or orifices located in the airflow in air handling or
ventilation systems.
V
Valve: A device that opens and closes to regulate the flow of liquids. Faucets, hose bibs, and
Ball are examples of valves.
Vane: That portion of an impeller which throws the water toward the volute.
Vapor Pressure: For a particular substance at any given temperature there is a pressure at
which the vapor of that substance is in equilibrium with its liquid or solid forms.
Velocity Head: The vertical distance a liquid must fall to acquire the velocity with which it flows
through the piping system. For a given quantity of flow, the velocity head will vary indirectly as
the pipe diameter varies.
220
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Venturi: A system for speeding the flow of the fluid, by constricting it in a cone-shaped
tube. Venturi are used to measure the speed of a fluid, by measuring the pressure
changes from one point to another along the venture. A venturi can also be used to
inject a liquid or a gas into another liquid. A pump forces the liquid flow through a tube
connected to:
A venturi to increase the speed of the fluid (restriction of the pipe diameter)
A short piece of tube connected to the gas source
A second venturi that decrease the speed of the fluid (the pipe diameter increase again)
After the first venturi the pressure in the pipe is lower, so the gas is sucked in the pipe.
Then the mixture enters the second venturi and slow down. At the end of the system a
mixture of gas and liquid appears and the pressure rise again to its normal level in the
pipe.
This technique is used for ozone injection in water.
The newest injector design causes complete mixing of injected materials (air, ozone or chemicals),
eliminating the need for other in-line mixers. Venturi injectors have no moving parts and are
maintenance free. They operate effectively over a wide range of pressures (from 1 to 250 psi) and
require only a minimum pressure difference to initiate the vacuum at the suction part. Venturis are
often built in thermoplastics (PVC, PE, PVDF), stainless steel or other metals.
The cavitation effect at the injection chamber provides an instantaneous mixing, creating
thousands of very tiny bubbles of gas in the liquid. The small bubbles provide and increased gas
exposure to the liquid surface area, increasing the effectiveness of the process (i.e. ozonation).
221
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Vibration: A force that is present on construction sites and must be considered. The vibrations
caused by backhoes, dump trucks, compactors and traffic on job sites can be substantial.
Viscosity: Informally, viscosity is the quantity that describes a fluid's resistance to flow. Fluids
resist the relative motion of immersed objects through them as well as to the motion of layers
with differing velocities within them. Formally, viscosity (represented by the symbol "eta") is
the ratio of the shearing stress (F/A) to the velocity gradient (vx/z or dvx/dz) in a fluid.
F vx F dvx
=( )( ) or = ( ) ( )
A z A dz
The more usual form of this relationship, called Newton's equation, states that the resulting shear
of a fluid is directly proportional to the force applied and inversely proportional to its viscosity. The
similarity to Newton's second law of motion (F = ma) should be apparent.
F vx F dvx
= or =
A z A dz
v dv
F=m or F = m
t dt
The SI unit of viscosity is the pascal second [Pas], which has no special name. Despite its self-
proclaimed title as an international system, the International System of Units has had very little
international impact on viscosity. The pascal second is rarely used in scientific and technical
publications today. The most common unit of viscosity is the dyne second per square centimeter
[dynes/cm2], which is given the name poise [P] after the French physiologist Jean Louis Poiseuille
(1799-1869). Ten poise equal one pascal second [Pas] making the centipoise [cP] and
millipascal second [mPas] identical.
There are actually two quantities that are called viscosity. The quantity defined above is
sometimes called dynamic viscosity, absolute viscosity, or simple viscosity to distinguish it from
the other quantity, but is usually just called viscosity. The other quantity called kinematic viscosity
(represented by the symbol "nu") is the ratio of the viscosity of a fluid to its density.
=
Kinematic viscosity is a measure of the resistive flow of a fluid under the influence of gravity. It is
frequently measured using a device called a capillary viscometer -- basically a graduated can with
a narrow tube at the bottom. When two fluids of equal volume are placed in identical capillary
viscometers and allowed to flow under the influence of gravity, a viscous fluid takes longer than
a less viscous fluid to flow through the tube. Capillary viscometers are discussed in more detail
later in this section. The SI unit of kinematic viscosity is the square meter per second [m2/s],
which has no special name. This unit is so large that it is rarely used. A more common unit of
kinematic viscosity is the square centimeter per second [cm2/s], which is given the name stoke
[St] after the English scientist George Stoke. This unit is also a bit too large and so the most
common unit is probably the square millimeter per second [mm2/s] or centistoke [cSt].
222
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Viscosity and Reference Temperatures: The viscosity of a fluid is highly temperature
dependent and for either dynamic or kinematic viscosity to be meaningful, the reference
temperature must be quoted. In ISO 8217 the reference temperature for a residual fluid is 100oC.
For a distillate fluid the reference temperature is 40oC.
For a liquid - the kinematic viscosity will decrease with higher temperature.
For a gas - the kinematic viscosity will increase with higher temperature.
Volute: The spiral-shaped casing surrounding a pump impeller that collects the liquid discharged
by the impeller.
Vorticity: Vorticity is defined as the circulation per unit area at a point in the flow field.
W
Water Freezing: The effects of water freezing in storage tanks can be minimized by alternating
water levels in the tank.
Water Storage Facility Inspection: During an inspection of your water storage facility, you should
inspect the Cathodic protection system including checking the anodes condition and the
connections. The concentration of polyphosphates that is used for corrosion control in storage tanks
is typically 5 mg/L or less. External corrosion of steel water storage facilities can be reduced with
Zinc or aluminum coatings. All storage facilities should be regularly sampled to determine the quality
of water that enters and leaves the facility. One tool or piece of measuring equipment is the Jackson
turbidimeter, which is a method to measure cloudiness in water.
Wave Drag: Wave drag refers to a sudden and very powerful drag that appears on aircrafts
flying at high-subsonic speeds.
Water Purveyor: The individuals or organization responsible to help provide, supply, and
furnish quality water to a community.
Water Works: All of the pipes, pumps, reservoirs, dams and buildings that make up a water
system.
Weber Number: A dimensionless value useful for analyzing fluid flows where there is an
interface between two different fluids. Since the Weber Number represents an index of the
inertial force to the surface tension force acting on a fluid element, it can be useful analyzing
thin films flows and the formation of droplets and bubbles.
223
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
224
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Appendixes and Charts
225
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Crude oil, 40o API 60oF 825
Crude oil, 35.6o API 60oF 847
o o
Crude oil, 32.6 API 60 F 862
o
Crude oil, California 60 F 915
Crude oil, Mexican 60oF 973
o
Crude oil, Texas 60 F 873
Cumene 25 860
Cyclohexane 20 779
Cyclopentane 20 745
Decane 25 726
Diesel fuel oil 20 to 60 15 820 - 950
Diethyl ether 20 714
o-Dichlorobenzene 20 1306
Dichloromethane 20 1326
Diethylene glycol 15 1120
Dichloromethane 20 1326
Dimethyl Acetamide 20 942
N,N-Dimethylformamide 20 949
Dimethyl Sulfoxide 20 1100
Dodecane 25 755
Ethane -89 570
Ether 25 73
Ethylamine 16 681
Ethyl Acetate 20 901
Ethyl Alcohol 20 789
Ethyl Ether 20 713
Ethylene Dichloride 20 1253
Ethylene glycol 25 1097
Fluorine refrigerant R-12 25 1311
Formaldehyde 45 812
Formic acid 10%oncentration 20 1025
Formic acid 80%oncentration 20 1221
Freon - 11 21 1490
Freon - 21 21 1370
o
Fuel oil 60 F 890
Furan 25 1416
Furforol 25 1155
o
Gasoline, natural 60 F 711
Gasoline, Vehicle 60oF 737
o
Gas oils 60 F 890
o
Glucose 60 F 1350 - 1440
Glycerin 25 1259
226
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Glycerol 25 1126
Heptane 25 676
Hexane 25 655
Hexanol 25 811
Hexene 25 671
Hydrazine 25 795
Iodine 25 4927
Ionene 25 932
Isobutyl Alcohol 20 802
Iso-Octane 20 692
Isopropyl Alcohol 20 785
Isopropyl Myristate 20 853
o
Kerosene 60 F 817
Linolenic Acid 25 897
Linseed oil 25 929
Methane -164 465
Methanol 20 791
Methyl Isoamyl Ketone 20 888
Methyl Isobutyl Ketone 20 801
Methyl n-Propyl Ketone 20 808
Methyl t-Butyl Ether 20 741
N-Methylpyrrolidone 20 1030
Methyl Ethyl Ketone 20 805
Milk 15 1020 - 1050
Naphtha 15 665
Naphtha, wood 25 960
Napthalene 25 820
Ocimene 25 798
Octane 15 918
Olive oil 20 800 - 920
Oxygen (liquid) -183 1140
Palmitic Acid 25 851
Pentane 20 626
Pentane 25 625
Petroleum Ether 20 640
Petrol, natural 60oF 711
o
Petrol, Vehicle 60 F 737
Phenol 25 1072
Phosgene 0 1378
Phytadiene 25 823
Pinene 25 857
Propane -40 583
227
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Propane, R-290 25 494
Propanol 25 804
Propylenearbonate 20 1201
Propylene 25 514
Propylene glycol 25 965
Pyridine 25 979
Pyrrole 25 966
Rape seed oil 20 920
Resorcinol 25 1269
Rosin oil 15 980
Sea water 25 1025
Silane 25 718
Silicone oil 760
Sodium Hydroxide (caustic
15 1250
soda)
Sorbaldehyde 25 895
Soya bean oil 15 924 - 928
Stearic Acid 25 891
Sulfuric Acid 95%onc. 20 1839
Sugar solution 68 brix 15 1338
Sunflower oil 20 920
Styrene 25 903
Terpinene 25 847
Tetrahydrofuran 20 888
Toluene 20 867
Toluene 25 862
Triethylamine 20 728
Trifluoroacetic Acid 20 1489
Turpentine 25 868
Water - pure 4 1000
Water - sea 77oF 1022
Whale oil 15 925
o-Xylene 20 880
1 kg/m = 0.001 g/cm = 0.0005780 oz/in = 0.16036 oz/gal (Imperial) = 0.1335 oz/gal (U.S.) = 0.0624 lb/ft3 =
3 3 3
0.000036127 lb/in3 = 1.6856 lb/yd3 = 0.010022 lb/gal (Imperial) = 0.008345 lb/gal (U.S) = 0.0007525 ton/yd3
228
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Dynamic or Absolute Viscosity Units Converting Table
The table below can be used to convert between common dynamic or absolute viscosity units.
Multiply by Convert to
Poise
Poiseuille (dyne s/ cm2
Convert from centiPoise kg / m h kgf s / m2
(Pa s) =
g / cm s)
Poiseuille
1 10 103 3.63 103 0.102
(Pa s)
Poise
(dyne s / cm2
0.1 1 100 360 0.0102
=
g / cm s)
centiPoise 0.001 0.01 1 3.6 0.00012
-4
kg / m h 2.78 10 0.00278 0.0278 1 2.83 10-5
kgf s / m2 9.81 98.1 9.81 103 3.53 104 1
2 3 4 6
lbf s / inch 6.89 10 6.89 10 6.89 10 2.48 107 703
lbf s / ft2 47.9 479 4.79 104 1.72 105 0.0488
2 5 6 8 8
lbf h / ft 1.72 10 1.72 10 1.72 10 6.21 10 1.76 104
3 3
lb / ft s 1.49 14.9 1.49 10 5.36 10 0.152
-4
lb / ft h 4.13 10 0.00413 0.413 1.49 4.22 10-5
Multiply by Convert to
2 2
Convert from lbf s / inch lbf s / ft lbf h / ft2 lb / ft s lb / ft h
Poiseuille
1.45 10-4 0.0209 5.8 10-6 0.672 2.42 103
(Pa s)
Poise
(dyne s / cm2
1.45 10-5 0.00209 5.8 10-7 0.0672 242
=
g / cm s)
centiPoise 1.45 10-7 2.9 10-5 5.8 10-9 0.000672 2.42
-8 -6 -9
kg / m h 4.03 10 5.8 10 1.61 10 0.000187 0.672
2 -5
kgf s / m 0.00142 20.5 5.69 10 6.59 2.37 104
lbf s / inch2 1 144 0.04 4.63 103 1.67 107
2
lbf s / ft 0.00694 1 0.000278 32.2 1.16 105
lbf h / ft2 25 3.6 103 1 1.16 105 4.17 108
lb / ft s 0.000216 0.0311 8.63 10-6 1 3.6 103
8 5 -9
lb / ft h 6 10- 1.16 10 2.4 10 0.000278 1
229
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Friction Loss Chart
The table below can be used to indicate the friction loss - feet of liquid per 100 feet of pipe - in
standard schedule 40 steel pipes.
Flow Rate Kinematic Viscosity - SSU
Pipe
Size 200 400 800 1500
31 100
(inches) (gpm) (l/s)
(Water) (~Cream)
(~Vegetable (~SAE (~Tomato (~SAE
oil) 10 oil) juice) 30 oil)
1/2 3 0.19 10.0 25.7 54.4 108.0 218.0 411.0
3 0.19 2.5 8.5 17.5 35.5 71.0 131.0
3/4
5 0.32 6.3 14.1 29.3 59.0 117.0 219.0
3 0.19 0.8 3.2 6.6 13.4 26.6 50.0
5 0.32 1.9 5.3 11.0 22.4 44.0 83.0
1 10 0.63 6.9 11.2 22.4 45.0 89.0 165.0
15 0.95 14.6 26.0 34.0 67.0 137.0
20 1.26 25.1 46 46.0 90.0 180.0
5 0.32 0.5 1.8 3.7 7.6 14.8 26.0
1 1/4 10 0.63 1.8 3.6 7.5 14.9 30.0 55.0
15 0.95 3.7 6.4 11.3 22.4 45.0 84.0
10 0.63 0.8 1.9 4.2 8.1 16.5 31.0
15 0.95 1.7 2.8 6.2 12.4 25.0 46.0
1 1/2 20 1.26 2.9 5.3 8.1 16.2 33.0 61.0
30 1.9 6.3 11.6 12.2 24.3 50.0 91.0
40 2.5 10.8 19.6 20.8 32.0 65.0 121.0
20 1.26 0.9 1.5 3.0 6.0 11.9 22.4
30 1.9 1.8 3.2 4.4 9.0 17.8 33.0
2 40 2.5 3.1 5.8 5.8 11.8 24.0 44.0
60 3.8 6.6 11.6 13.4 17.8 36.0 67.0
80 5.0 1.6 3.0 3.2 4.8 9.7 18.3
30 1.9 0.8 1.4 2.2 4.4 8.8 16.6
40 2.5 1.3 2.5 3.0 5.8 11.8 22.2
2 1/2 60 3.8 2.7 5.1 5.5 8.8 17.8 34.0
80 5.0 4.7 8.3 9.7 11.8 24.0 44.0
100 6.3 7.1 12.2 14.1 14.8 29.0 55.0
60 3.8 0.9 1.8 1.8 3.7 7.3 13.8
100 6.3 2.4 4.4 5.1 6.2 12.1 23.0
125 7.9 3.6 6.5 7.8 8.1 15.3 29.0
3
150 9.5 5.1 9.2 10.4 11.5 18.4 35.0
175 11.0 6.9 11.7 13.8 15.8 21.4 40.0
200 12.6 8.9 15.0 17.8 20.3 25.0 46.0
80 5.0 0.4 0.8 0.8 1.7 3.3 6.2
4 100 6.3 0.6 1.2 1.3 2.1 4.1 7.8
125 7.9 0.9 1.8 2.1 2.6 5.2 9.8
230
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
150 9.5 1.3 2.4 2.9 3.1 6.2 11.5
175 11.0 1.8 3.2 4.0 4.0 7.4 13.7
200 12.6 2.3 4.2 5.1 5.1 8.3 15.5
250 15.8 3.5 6.0 7.4 8.0 10.2 19.4
125 7.9 0.1 0.3 0.3 0.52 1.0 1.9
150 9.5 0.2 0.3 0.4 0.6 1.2 2.3
175 11.0 0.2 0.4 0.5 0.7 1.4 2.6
6 200 12.6 0.3 0.6 0.7 0.8 1.6 3.0
250 15.8 0.5 0.8 1.0 1.0 2.1 3.7
300 18.9 1.1 8.5 10.0 11.6 12.4 23.0
400 25.2 1.1 1.9 2.3 2.8 3.2 6.0
250 15.8 0.1 0.2 0.3 0.4 0.7 1.2
8 300 18.9 0.3 1.2 1.4 1.5 2.5 4.6
400 25.2 0.3 0.5 0.6 0.7 1.1 2.0
300 18.9 0.1 0.3 0.4 0.4 0.8 1.5
10
400 25.2 0.1 0.2 0.2 0.2 0.4 0.8
231
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Hazen-Williams Coefficients
Hazen-Williams factor for some common piping materials. Hazen-Williams coefficients are used in the Hazen-
Williams equation for friction loss calculation in ducts and pipes. Coefficients for some common materials used
in ducts and pipes can be found in the table below:
Hazen-Williams Coefficient
Material
-C-
Asbestos Cement 140
Brass 130 - 140
Brick sewer 100
Cast-Iron - new unlined (CIP) 130
Cast-Iron 10 years old 107 - 113
Cast-Iron 20 years old 89 - 100
Cast-Iron 30 years old 75 - 90
Cast-Iron 40 years old 64-83
Cast-Iron, asphalt coated 100
Cast-Iron, cement lined 140
Cast-Iron, bituminous lined 140
Cast-Iron, wrought plain 100
Concrete 100 - 140
Copper or Brass 130 - 140
Ductile Iron Pipe (DIP) 140
Fiber 140
Galvanized iron 120
Glass 130
Lead 130 - 140
Plastic 130 - 150
Polyethylene, PE, PEH 150
PVC, CPVC 150
Smooth Pipes 140
Steel new unlined 140 - 150
Steel
Steel, welded and seamless 100
Steel, interior riveted, no
100
projecting rivets
Steel, projecting girth rivets 100
Steel, vitrified, spiral-riveted 90 - 100
Steel, corrugated 60
Tin 130
Vitrified Clays 110
Wood Stave 110 - 120
232
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Pressure Head
A pressure difference of 5 psi (lbf/in2) is equivalent to
5 (lbf/in2) 12 (in/ft) 12 (in/ft) / 62.4 (lb/ft3) = 11.6 ft of water
5 (lbf/in2) 12 (in/ft) 12 (in/ft) / 847 (lb/ft3) = 0.85 ft of mercury
When specific weight of water is 62.4 (lb/ft3) and specific weight of mercury is 847 (lb/ft3).
Heads at different velocities can be taken from the table below:
Velocity Head Water
(ft/sec) (ft)
0.5 0.004
1.0 0.016
1.5 0035
2.0 0.062
2.5 0.097
3.0 0.140
3.5 0.190
4.0 0.248
4.5 0.314
5.0 0.389
5.5 0.470
6.0 0.560
6.5 0.657
7.0 0.762
7.5 0.875
8.0 0.995
8.5 1.123
9.0 1.259
9.5 1.403
10.0 1.555
11.0 1.881
12.0 2.239
13.0 2.627
14.0 3.047
15.0 3.498
16.0 3.980
17.0 4.493
18.0 5.037
19.0 5.613
20.0 6.219
21.0 6.856
22.0 7.525
1 ft (foot) = 0.3048 m = 12 in = 0.3333 yd.
233
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
234
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Thermal Properties of Water
235
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
185 1120 882 113 4.444 2.187
190 1260 876 114 4.460 2.236
195 1400 870 115 4.404 2.282
200 1550 863 116 4.497 2.329
220
225 2550 834 120 4.648 2.569
240
250 3990 800 125 4.867 2.797
260
275 5950 756 132 5.202 3.022
300 8600 714 140 5.769 3.256
325 12130 654 153 6.861 3.501
350 16540 575 174 10.10 3.781
360 18680 526 190 14.60 3.921
236
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Viscosity Converting Chart
The viscosity of a fluid is its resistance to shear or flow, and is a measure of the fluids adhesive/
cohesive or frictional properties. This arises because of the internal molecular friction within the
fluid producing the frictional drag effect. There are two related measures of fluid viscosity which
are known as dynamic and kinematic viscosity.
Dynamic viscosity is also termed "absolute viscosity" and is the tangential force per unit area
required to move one horizontal plane with respect to the other at unit velocity when maintained
a unit distance apart by the fluid.
Centipoise Saybolt
(CPS) Poise Centistokes Stokes Seconds
Millipascal (P) (cSt) (S) Universal
(mPas) (SSU)
1 0.01 1 0.01 31
2 0.02 2 0.02 34
4 0.04 4 0.04 38
7 0.07 7 0.07 47
10 0.1 10 0.1 60
15 0.15 15 0.15 80
20 0.2 20 0.2 100
25 0.24 25 0.24 130
30 0.3 30 0.3 160
40 0.4 40 0.4 210
50 0.5 50 0.5 260
60 0.6 60 0.6 320
70 0.7 70 0.7 370
80 0.8 80 0.8 430
90 0.9 90 0.9 480
100 1 100 1 530
120 1.2 120 1.2 580
140 1.4 140 1.4 690
160 1.6 160 1.6 790
180 1.8 180 1.8 900
200 2 200 2 1000
220 2.2 220 2.2 1100
240 2.4 240 2.4 1200
260 2.6 260 2.6 1280
280 2.8 280 2.8 1380
300 3 300 3 1475
320 3.2 320 3.2 1530
237
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
340 3.4 340 3.4 1630
360 3.6 360 3.6 1730
380 3.8 380 3.8 1850
400 4 400 4 1950
420 4.2 420 4.2 2050
440 4.4 440 4.4 2160
460 4.6 460 4.6 2270
480 4.8 480 4.8 2380
500 5 500 5 2480
550 5.5 550 5.5 2660
600 6 600 6 2900
700 7 700 7 3380
800 8 800 8 3880
900 9 900 9 4300
1000 10 1000 10 4600
1100 11 1100 11 5200
1200 12 1200 12 5620
1300 13 1300 13 6100
1400 14 1400 14 6480
1500 15 1500 15 7000
1600 16 1600 16 7500
1700 17 1700 17 8000
1800 18 1800 18 8500
1900 19 1900 19 9000
2000 20 2000 20 9400
2100 21 2100 21 9850
2200 22 2200 22 10300
2300 23 2300 23 10750
2400 24 2400 24 11200
238
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Various Flow Section Channels and their Geometric Relationships:
Area, wetted perimeter and hydraulic diameter for some common geometric sections like
rectangular channels
trapezoidal channels
triangular channels
circular channels.
Rectangular Channel
Flow Area
Flow area of a rectangular channel can be expressed as
A = b h (1)
where
A = flow area (m2, in2)
b = width of channel (m, in)
h = height of flow (m, in)
Wetted Perimeter
Wetted perimeter of a rectangular channel can be expressed as
P = b + 2 h (1b)
where
P = wetted perimeter (m, in)
Hydraulic Radius
Hydraulic radius of a rectangular channel can be expressed as
Rh = b h / (b + 2 y) (1c)
where
Rh = hydraulic radius (m, in)
Trapezoidal Channel
Flow Area
Flow area of a trapezoidal channel can be expressed as
A = (a + z h) h (2)
where
z = see figure above (m, in)
Wetted Perimeter
Wetted perimeter of a trapezoidal channel can be expressed as
P = a + 2 h (1 + z2)1/2 (2b)
Hydraulic Radius
Hydraulic radius of a trapezoidal channel can be expressed as
Rh = (a + z h) h / a + 2 h (1 + z2)1/2 (2c)
239
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Triangular Channel
Flow Area
Flow area of a triangular channel can be expressed as
A = z h2 (3)
where
z = see figure above (m, in)
Wetted Perimeter
Wetted perimeter of a triangular channel can be expressed as
P = 2 h (1 + z2)1/2 (3b)
Hydraulic Radius
Hydraulic radius of a triangular channel can be expressed as
Rh = z h / 2 (1 + z2)1/2 (3c)
Circular Channel
Flow Area
Flow area of a circular channel can be expressed as
A = D2/4 ( - sin(2 )/2) (4)
where
D = diameter of channel
= cos-1(1 - h/r)
Wetted Perimeter
Wetted perimeter of a circular channel can be expressed as
P = D (4b)
Hydraulic Radius
Hydraulic radius of a circular channel can be expressed as
Rh = D/8 [1 - sin(2 ) / (2 )] (4c)
where
v = velocity (ft, m)
g = acceleration of gravity (32.174 ft/s2, 9.81 m/s2)
240
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Heads at different velocities can be taken from the table below:
Velocity Velocity Head
-v- - v2/2g -
(ft/sec) (ft Water)
0.5 0.004
1.0 0.016
1.5 0035
2.0 0.062
2.5 0.097
3.0 0.140
3.5 0.190
4.0 0.248
4.5 0.314
5.0 0.389
5.5 0.470
6.0 0.560
6.5 0.657
7.0 0.762
7.5 0.875
8.0 0.995
8.5 1.123
9.0 1.259
9.5 1.403
10.0 1.555
11.0 1.881
12.0 2.239
13.0 2.627
14.0 3.047
15.0 3.498
16.0 3.980
17.0 4.493
18.0 5.037
19.0 5.613
20.0 6.219
21.0 6.856
22.0 7.525
241
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Some Commonly used Thermal Properties for Water
242
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Reynolds Number
Turbulent or laminar flow is determined by the dimensionless Reynolds Number.
The Reynolds number is important in analyzing any type of flow when there is substantial velocity
gradient (i.e., shear.) It indicates the relative significance of the viscous effect compared to the
inertia effect. The Reynolds number is proportional to inertial force divided by viscous force.
The table below shows Reynolds Number for one liter of water flowing through pipes of different
dimensions:
Pipe Size
(inches) 1 1? 2 3 4 6 8 10 12 18
(mm) 25 40 50 75 100 150 200 250 300 450
Reynolds
number
with 835 550 420 280 210 140 105 85 70 46
one (1)
liter/min
Reynolds
number
with 3800 2500 1900 1270 950 630 475 380 320 210
one (1)
gal/min
243
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Linear Motion Formulas
Velocity can be expressed as (velocity = constant):
v = s / t (1a)
where
v = velocity (m/s, ft/s)
s = linear displacement (m, ft)
t = time (s)
where
V0 = linear velocity at time zero (m/s, ft/s)
where
ds = change of displacement (m, ft)
dt = change in time (s)
where
dv = change in velocity (m/s, ft/s)
244
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Water - Dynamic and Kinematic Viscosity
Dynamic and Kinematic Viscosity of Water in Imperial Units (BG units):
Dynamic Kinematic
Temperature
Viscosity Viscosity
-t-
-- --
(oF)
10-5 (lbs./ft2) 10-5 (ft2/s)
32 3.732 1.924
40 3.228 1.664
50 2.730 1.407
60 2.344 1.210
70 2.034 1.052
80 1.791 0.926
90 1.500 0.823
100 1.423 0.738
120 1.164 0.607
140 0.974 0.511
160 0.832 0.439
180 0.721 0.383
200 0.634 0.339
212 0.589 0.317
245
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Water and Speed of Sound
Speed of sound in water at temperatures between 32 - 212oF (0-100oC) - imperial and SI units
Speed of Sound in Water - in imperial units (BG units)
Temperature Speed of Sound
-t- -c-
(oF) (ft/s)
32 4,603
40 4,672
50 4,748
60 4,814
70 4,871
80 4,919
90 4,960
100 4,995
120 5,049
140 5,091
160 5,101
180 5,095
200 5,089
212 5,062
246
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Math Conversion Factors
1 PSI = 2.31 Feet of Water LENGTH
1 Foot of Water = .433 PSI 12 Inches = 1 Foot
1.13 Feet of Water = 1 Inch of Mercury 3 Feet = 1 Yard
454 Grams = 1 Pound 5,280 Feet = 1 Mile
2.54 CM =Inch
1 Gallon of Water = 8.34 Pounds AREA
1 mg/L = 1 PPM 144 Square Inches = 1 Square Foot
17.1 mg/L = 1 Grain/Gallon 43,560 Square Feet = 1 Acre
1% = 10,000 mg/L VOLUME
694 Gallons per Minute = MGD 1000 Milliliters = 1 Liter
1.55 Cubic Feet per Second = 1 MGD 3.785 Liters = 1 Gallon
60 Seconds = 1 Minute 231 Cubic Inches = 1 Gallon
1440 Minutes = 1 Day 7.48 Gallons = 1 Cubic Foot of Water
.746 kW = 1 Horsepower 62.38 Pounds = 1 Cubic Foot of Water
Dimensions
SQUARE: Area (sq. ft) = Length X Width
Volume (cu.ft.) = Length (ft) X Width (ft) X Height (ft)
CYLINDER: Volume (Cu. ft) = 3.14 X Radius (ft) X Radius (ft) X Depth (ft)
General Conversions
Multiply > to get
to get < Divide
cc/min 1 mL/min
cfm (ft3/min) 28.31 L/min
3
cfm (ft /min) 1.699 m3/hr
cfh (ft3/hr) 472 mL/min
3
cfh (ft /hr) 0.125 GPM
GPH 63.1 mL/min
GPH 0.134 cfh
GPM 0.227 m3/hr
GPM 3.785 L/min
oz/min 29.57 mL/min
247
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
PERCENT EFFICIENCY = In Out X 100
In
0
TEMPERATURE: F = (0C X 9/5) + 32 9/5 =1.8
0
C = (0F - 32) X 5/9 5/9 = .555
FLOW RATE (gpm): Flow Rate (gpm) = 2.83 (Diameter, in)2 (Distance, in)
Height, in
% SLOPE = Rise (feet) X 100
Run (feet)
248
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
SLOPE = Rise (ft) SLOPE (%) = Rise (ft) X 100
Run (ft) Run (ft)
MANNINGS EQUATION
Q = Allowable time for decrease in pressure from 3.5 PSI to 2.5 PSI
q = As below
249
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
250
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Formula/Conversion Table
Acid Feed Rate = (Waste Flow) ( Waste Normality)
Acid Normality
Discharge = Volume
Time
251
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Efficiency, % = (In Out) (100%)
In
Mean Cell Residence Time (MCRT) = Suspended Solids in Aeration System, lbs
SS Wasted, lbs / day + SS lost, lbs / day
252
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Oxygen Uptake = Oxygen Usage
Time
253
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Total suspended solids (TSS), mg/L =
(Dry weight, mg)(1,000 mL/L) (Sample vol., mL)
Conversion Factors
1 acre = 43,560 square feet
1 cubic foot = 7.48 gallons
1 foot = 0.305 meters
1 gallon = 3.79 liters
1 gallon = 8.34 pounds
1 grain per gallon = 17.1 mg/L
1 horsepower = 0.746 kilowatts
1 million gallons per day = 694.45 gallons per minute
1 pound = 0.454 kilograms
1 pound per square inch = 2.31 feet of water
1% = 10,000 mg/L
Degrees Celsius = (Degrees Fahrenheit - 32) (5/9)
Degrees Fahrenheit = (Degrees Celsius * 9/5) + 32
64.7 grains = 1 cubic foot
1,000 meters = 1 kilometer
1,000 grams = 1 kilogram
1,000 milliliters = 1 liter
144 square inches = 1 square foot
1.55 cubic feet per second = 1 MGD
1 meter = 3.28 feet
= 3.141
254
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Math Review Section-Practice Exam
Math Problems with Complete Solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
Cube Formula
V= (L) (W) (D)
Volume= Length X Width X Depth
Cylinder Formula
V= (.785) (D2) (d)
2. The liquid in a tank weighs 800 pounds, how many gallons are in the tank?
3. Convert a flow rate of 953 gallons per minute to million gallons per day.
There is 1440 minutes in a day.
4. Convert a flow rate of 610 gallons per minute to millions of gallons per day.
255
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
V= (L) (W) (D) X 7.48 =
9. In Liters?
V= (L) (W) (D) X 7.48 =_________ X 3.785
10. A tank holds 67,320 gallons of water. The length is 60 and the width is 15. How deep is
the tank?
11. The diameter of a tank is 60 and the depth is 25. How many gallons does it hold?
Cylinder Formula
V= (.785) (D2) (d)
.785 X 60 X 60 X 25 X 7.48 =
Math Problems with Complete Solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
12. The diameter of a tank is 15 Centimeters or cm and the depth is 25 cm, what is the
volume in liters?
256
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Percentage and Fractions
Let's look again at the sequence of numbers 1000, 100, 10, 1, and continue the pattern to get
new terms by dividing previous terms by 10:
.1 = 1/10
.01 = 1/100
.001 = 1/1000
So just as the digits to the left of the decimal represent 1's, 10's, 100's, and so forth, digits to the
right of the decimal point represent 1/10's, 1/100's, 1/1000's, and so forth.
Lets express 5% as a decimal. 5 100 = 0.05 or you can move the decimal point to the left
two places.
.5
-----
10 ) 5.0
50
----
So 5/10 (five tenths) = .5 (five tenths).
257
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
This is not your final assignmentplease download the assignment off the website.
258
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Flow and Velocity
This depends on measuring the average velocity of flow and the cross-sectional area of the
channel and calculating the flow from:
Q(m3/s) = A(m2) X V(m/s)
Or
Q=AXV
Q CFM = Cubic Ft, Inches, Yards of time, Sec, Min, Hrs, Days
A = Area, squared Length X Width
V f/m = Inch, Ft, Yards, Per Time, Sec, Min, Ft or Speed
13. A channel is 3 feet wide and has water flowing to a depth of 2.5 feet. If the velocity through
the channel is 2 fps or feet per second, what is the cfs flow rate through the channel?
Q=AXV
14. A channel is 40 inches wide and has water flowing to a depth of 1.5 ft. If the velocity of the
water is 2.3 fps, what is the cfs flow in the channel? Q = A X V
First we must convert 40 inches to feet.
40 12 = 3.333 feet
15. A channel is 3 feet wide and has a water flow at a velocity of 1.5 fps. If the flow through the
channel is 8.1 cfs, what is the depth of the water?
Q = 8.1 cfs
V = 1.5 fps
A=?
16. The flow through a 6 inch diameter pipe is moving at a velocity of 3 ft/sec. What is the cfs
flow rate through the pipeline?
Q=
A = .785 X .5 X .5 =
V = 3 fps
This is not your final assignmentplease download the assignment off the website.
259
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
17. An 8 inch diameter pipe has water flowing at a velocity of 3.4 fps. What is the gpm flow rate
through the pipe?
18. A 6 inch diameter pipe delivers 280 gpm. What is the velocity of flow in the pipe in ft/sec?
Take the water out of the pipe. 280 gpm 7.48 60 sec/min = ________ cfs
Q=
A = .785 X .5 X .5 =
V=
19. A new section of 12 inch diameter pipe is to be disinfected before it is placed in service. If
the length is 2000 feet, how many gallons of 5% NaOCl will be need for a dosage of 200 mg/L?
Cylinder Formula
V= (.785) (D2) (d)
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal if 100% concentrate.
If not, divide the lbs/day by the given %
20. A section of 6 inch diameter pipe is to be filled with water. The length of the pipe is 1320
feet long. How many kilograms of chlorine will be needed for a chlorine dose of 3 mg/L?
Pounds per day formula = Flow X Dose X 8.34 X .454 Grams per pound
21. Determine the chlorinator setting in pounds per 24 hour period to treat a flow of 3.4 MGD
with a chlorine dose of 3.35 mg/L?
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal
260
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
22. To correct an odor problem, you use chlorine continuously at a dosage of 15 mg/L and a
flow rate of 85 GPM. Approximately how much will odor control cost annually if chlorine is $0.17
per pound?
______ MGD X 15 mg/L X 8.34 lbs/gal X $0.17 per pound X 365 days/year =
23. A wet well measures 8 feet by 10 feet and 3 feet in depth between the high and low levels.
A pump empties the wet well between the high and low levels 9 times per hour, 24 hours a day.
Neglecting inflow during the pumping cycle, calculate the flow into the pump station in millions of
gallons per day (MGD).
Math problems with complete solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
This is not your final assignmentplease download the assignment off the website.
261
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
24. A sewage treatment plant has a flow of 0.7 MGD and a BOD of 225 mg/L. On the basis of
a national average of 0.2 lbs BOD per capita per day, what is the approximate population
equivalent of the plant?
25. What is the detention time of a clarifier with a 250,000 gallon capacity if it receives a flow of
3.0 MGD?
262
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Crazy Math Section
The metric system is known for its simplicity. All units of measurement in the metric system are
based on decimalsthat is, units that increase or decrease by multiples of ten. A series of Greek
decimal prefixes is used to express units of ten or greater; a similar series of Latin decimal prefixes
is used to express fractions. For example, deca equals ten, hecto equals one hundred, kilo equals
one thousand, mega equals one million, giga equals one billion, and tera equals one trillion. For
units below one, deci equals one-tenth, centi equals one-hundredth, milli equals one-thousandth,
micro equals one-millionth, nano equals one-billionth, and pico equals one-trillionth.
Math Problems with Complete Solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
This is not your final assignmentplease download the assignment off the website.
263
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
264
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Temperature
There are two main temperature scales. The Fahrenheit Scale (used in the US), and the
Celsius Scale (part of the Metric System, used in most other Countries)
They both measure the same thing (temperature!), just using different numbers.
If you freeze water, it measures 0 in Celsius, but 32 in Fahrenheit
If you boil water, it measures 100 in Celsius, but 212 in Fahrenheit
The difference between freezing and boiling is 100 in Celsius, but 180 in Fahrenheit.
Conversion Method
Looking at the diagram, notice:
The scales start at a different number (32 vs. 0), so we will need to add or subtract 32
The scales rise at a different rate (180 vs. 100), so we will also need to multiply
And this is how it works out:
To convert from Celsius to Fahrenheit, first multiply by 180/100, then add 32
To convert from Fahrenheit to Celsius, first subtract 32, then multiply by 100/180
20 o X 1.8 + 32 = F
4o X 1.8 + 32 = F
265
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
266
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Water Treatment Filters
29. A 19 foot wide by 31 foot long rapid sand filter treats a flow of 2,050 gallons per minute.
Calculate the filtration rate in gallons per minute per square foot of filter area.
30. A 26 foot wide by 36 foot wide long rapid sand filter treats a flow of 2,500 gallons per minute.
Calculate the filtration rate in gallons per minute per square foot of filter area.
Chemical Dose
31. A pond has a surface area of 51,500 square feet and the desired dose of a chemical is 6.5
lbs per acre. How many pounds of the chemical will be needed?
32. A pond having a volume of 6.85 acre feet equals how many millions of gallons?
33. Alum is added in a treatment plant process at a concentration of 10.5 mg/L. What should the
setting on the feeder be in pounds per day if the plant is treating 3.5 MGD?
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal
Q=AV Review
34. An 8 inch diameter pipe has water flowing at a velocity of 3.4 fps. What is the GPM flow rate
through the pipe?
Q = 1.18 CFS x 60 Seconds x 7.48 GAL/CU.FT = 532 GPM
A = .785 X .667 X .667 X 1 = .349 Sq. Ft.
V= 3.4 Feet per second
35. A 6 inch diameter pipe delivers 280 GPM. What is the velocity of flow in the pipe in Ft/Sec?
280 GPM 60 seconds in a minute 7.48 gallons in a cu.ft. = .623 CFS
Q = .623
A = .785 X.5 X .5 =.196 Sq. Ft.
V = 3.17 Ft/Second
267
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
268
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Collections
36. A 24-inch sewer carries an average daily flow of 5 MGD. If the average daily flow per
person from the area served is 110 GPCD (gallons per capita per day), approximately how
many people discharge into the wastewater collection system?
37. Using a dose rate of 5 mg/L, how many pounds of chlorine per day should be used if the
flow rate is 1.2 MGD?
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal
38. What capacity blower will be required to ventilate a manhole which is 3.5 feet in diameter
and 17 feet deep? The air exchange rate is 16 air changes per hour.
.785 X 3.5 X 3.5 X 17 X 16 = ____________ CFH
39. Approximately how many feet of drop are in 455 feet of 8-inch sewer with a 0.0475 ft/ft.
slope?
455 X 0.0475 =
40. How much brake horsepower is required to meet the following conditions: 250 gpm, total
head = 110 feet? The submersible pump that is being specified is a combined 64% efficient?
41. How wide is a trench at ground surface if a sewer trench is 2 feet wide at the bottom, 10
feet deep and the sides have been sloped at a 4/5 horizontal to 1 vertical (3/4:1) ratio?
269
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
42. A float arrives in a manhole 550 feet down stream three minutes and thirty seconds from its
release point. What is the velocity in ft/sec.?
Velocity ft/sec = distance time
43. A new sewer line plan calls out a 0.6% slope of the line. An elevation reading of 108.8 feet
at the manhole discharge and an elevation of 106.2 feet at a distance of 200 feet from the
manhole are recorded. What is the existing slope of the line that has been installed?
44. A triangular pile of spoil is 12 feet high and 12 feet wide at the base. The pile is 60' long. If
the dump truck hauls 9 cubic yards of dirt, how many truck loads will it take to remove all of the
spoil?
Given the base and the height of a triangle, we can find the area. Given the area and either the base
or the height of a triangle, we can find the other dimension. The formula for area of a triangle is:
45. A red dye is poured into an upstream manhole connected to a 12 inch sewer. The dye first
appears in a manhole 400 feet downstream 3 minutes later. After 3 minutes and 40 seconds the
dye disappears. Estimate the flow velocity in feet per second?
Velocity ft/sec = distance time
Make sure and convert time and average it.
Math problems with complete solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
This is not your final assignmentplease download the assignment off the website.
270
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
46. Calculate the total dosage in pounds of a chemical. Assume the sewer is completely filled
with the concentration. Pipe diameter: 18 inches, Pipe length: 420 feet, Dose: 120 mg/L.
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal
Math problems with complete solution can be found at the rear of this section.
Please try to work the problems without looking at the solution.
271
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Short Answers
1. 7.48 X 10 = 74.8
2. 800 8.34 = 95.92 gallons
3. 1372320 or 1.3 MGD
4. 610 X 1441 = 878400 or 0.87 MGD
5. 550 60 = 9.167 gpm
6. 9.167 X 3.785 = 34.697 Liters
7. 630 Area 4712 gallons
8. 18,750 cu. ft. X 7.48 = 140250 gallons
9. 140250 X 3.785 = 530846 Liters
10. 10 feet deep
11. 528462 or .5 MG
12. 1.166 Gallons X 3.785 = 4.412 Liters
13. 15 cfs
14. 11.49 cfs
15. 1.8
16. .58875 cfs
17. 533 gpm
18. 3.2 ft/sec
19. 46.9 gal
20. .02 kg
21. 94.9 lbs/day
22. $950.12
23. .388 or .39 MGD
24. 6567.75
25. 2 hrs.
26. 4.5 grams
27. 68 F
28. 39F
29. 3.48 gpm/sq.ft.
30. 2.67 gpm/sq.ft.
31. 7.68 lbs
32. 2.231 MG
33. 306.495
34. 532 gpm
35. 3.2 fps
36. 45454.5 people
37. 50.04 lbs
38. 2615.6 cfh
39. 21.61 ft
40. 10.85 bhp
41. 17 ft
42. 2.62 fps
43. .013 or 1.3%
44. 17.7 or 18 trucks
45. 2 fps
46. 5.55 lbs
Math problems with complete solution can be found on the next page.
272
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Math Problems with Complete Solution
Cube Formula
V= (L) (W) (D)
Volume= Length X Width X Depth
Cylinder Formula
V= (.785) (D2) (d)
2. The liquid in a tank weighs 800 pounds, how many gallons are in the tank?
4. Convert a flow rate of 610 gallons per minute to millions of gallons per day.
273
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
6. Now, convert this number to liters per second.
9.17 gal/sec X 3.79 Liters/gal + 34.75 Liter/sec or 34.697
7. A tank is 6 X 15 x 7 and can hold a maximum of ____________ gallons of water.
V= (L) (W) (D) X 7.48 =
9. In Liters?
V= (L) (W) (D) X 7.48 =_________ X 3.785
10. A tank holds 67,320 gallons of water. The length is 60 and the width is 15. How deep is
the tank?
11. The diameter of a tank is 60 and the depth is 25. How many gallons does it hold?
Cylinder Formula
V= (.785) (D2) (d)
.785 X 60 X 60 X 25 X 7.48 =
Or
274
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Math Problems with Complete Solution
Water Treatment Production Math Numbering System
In water treatment, we express our production numbers in Million Gallon numbers. Example
2,000,000 or 2 million gallons would be expressed as 2 MG or 2 MGD.
Hints. A million has six zeros, you can always divide your final number by 1,000,000 or move
the decimal point to the left six places. Example 528,462 would be expressed .56 MGD.
12. The diameter of a tank is 15 Centimeters or cm and the depth is 25 cm, what is the
volume in liters?
13. A channel is 3 feet wide and has water flowing to a depth of 2.5 feet. If the velocity through
the channel is 2 fps or feet per second, what is the cfs flow rate through the channel?
Q=AXV
Q = 15
A= 3 X 2.5 = 7.5
V= 2 fps
Or
Area is 7.5 cubic feet
Velocity is 2 fps
14. A channel is 40 inches wide and has water flowing to a depth of 1.5 ft. If the velocity of the
water is 2.3 fps, what is the cfs flow in the channel? Q = A X V
275
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
15. A channel is 3 feet wide and has a water flow at a velocity of 1.5 fps. If the flow through the
channel is 8.1 cfs, what is the depth of the water?
Q = 8.1 cfs
V = 1.5 fps
A=?
16. The flow through a 6 inch diameter pipe is moving at a velocity of 3 ft/sec. What is the cfs
flow rate through the pipeline?
Q=
A = .785 X .5 X .5 =
V = 3 fps
17. An 8 inch diameter pipe has water flowing at a velocity of 3.4 fps. What is the gpm flow
rate through the pipe?
18. A 6 inch diameter pipe delivers 280 gpm. What is the velocity of flow in the pipe in ft/sec?
Take the water out of the pipe. 280 gpm 7.48 60 sec/min = ________ cfs
Q=
A = .785 X .5 X .5 =
V=
19. A new section of 12 inch diameter pipe is to be disinfected before it is placed in service. If
the length is 2000 feet, how many gallons of 5% NaOCl will be need for a dosage of 200 mg/L?
276
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Cylinder Formula
V= (.785) (D2) (d)
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal if 100% concentrate.
If not, divide the lbs/day by the given %
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal if 100% concentrate.
If not, divide the lbs/day by the given %
0.0117436 MG X 200 mg/L X 8.34 =19.588 lbs/day .05 or 5% = 391.76 lbs 8.34 lb/gal =
46.9 gallons
20. A section of 6 inch diameter pipe is to be filled with water. The length of the pipe is 1320
feet long. How many kilograms of chlorine will be needed for a chlorine dose of 3 mg/L?
Pounds per day formula = Flow X Dose X 8.34 X .454 Grams per pound
21. Determine the chlorinator setting in pounds per 24 hour period to treat a flow of 3.4 MGD
with a chlorine dose of 3.35 mg/L?
Pounds per day formula = Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal
277
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
22. To correct an odor problem, you use chlorine continuously at a dosage of 15 mg/L and a
flow rate of 85 GPM. Approximately how much will odor control cost annually if chlorine is $0.17
per pound?
______ MGD X 15 mg/L X 8.34 lbs/gal X $0.17 per pound X 365 days/year =
.1224 MGD X 15 mg/L X 8.34 lbs/gal X $0.17 per pound X 365 days/year = $950.12
23. A wet well measures 8 feet by 10 feet and 3 feet in depth between the high and low levels.
A pump empties the wet well between the high and low levels 9 times per hour, 24 hours a day.
Neglecting inflow during the pumping cycle, calculate the flow into the pump station in millions of
gallons per day (MGD).
LXWXH
(8 X 10 X 3) = 240 CF X 7.48 gal/cf = 1795.2 X 9 X 24 =387763 gallons/day or rounds
to .388 MGD
24. A sewage treatment plant has a flow of 0.7 MGD and a BOD of 225 mg/L. On the basis of
a national average of 0.2 lbs BOD per capita per day, what is the approximate population
equivalent of the plant?
Population equivalent
(0.7 MGD) (22.5 mg/L) (8.34 Lbs/gal) = 6,567.75 people
0.2 Lbs BOD/Day/Person
25. What is the detention time of a clarifier with a 250,000 gallon capacity if it receives a flow of
3.0 MGD?
278
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
27. Convert 20 degrees Celsius to degrees Fahrenheit.
20 o C X 1.8 + 32 = 68 F
30. A 26 foot wide by 36 foot wide long rapid sand filter treats a flow of 2,500 gallons per minute.
Calculate the filtration rate in gallons per minute per square foot of filter area.
(26 X 36) = 936 Sq. Ft
Chemical Dose
31. A pond has a surface area of 51,500 square feet and the desired dose of a chemical is 6.5
lbs per acre. How many pounds of the chemical will be needed?
32. A pond having a volume of 6.85 acre feet equals how many millions of gallons?
1 acre foot = 325851 X 6.85 =2.231MG
33. Alum is added in a treatment plant process at a concentration of 10.5 mg/L. What should the
setting on the feeder be in pounds per day if the plant is treating 3.5 MGD?
Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal = Pounds per day formula
279
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Q=AV Review
34. An 8 inch diameter pipe has water flowing at a velocity of 3.4 fps. What is the GPM flow rate
through the pipe?
Q = 1.18 CFS x 60 Seconds x 7.48 GAL/CU.FT = 532 GPM
A = .785 X .667 X .667 X 1 = .349 Sq. Ft.
V= 3.4 Feet per second
VXA+Q
Velocity 3.4 fps X .349 Sq.ft = 1.1866 CFS X 60 seconds X 7.48 gal/Cu.ft + 532.5 or 533
35. A 6 inch diameter pipe delivers 280 GPM. What is the velocity of flow in the pipe in Ft/Sec?
Q = .623
A = .785 X.5 X .5 =.196 Sq. Ft.
V = 3.17 Ft/Second
Collections
36. A 24-inch sewer carries an average daily flow of 5 MGD. If the average daily flow per
person from the area served is 110 GPCD (gallons per capita per day), approximately how
many people discharge into the wastewater collection system?
37. Using a dose rate of 5 mg/L, how many pounds of chlorine per day should be used if the
flow rate is 1.2 MGD?
Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal = Pounds per day formula
38. What capacity blower will be required to ventilate a manhole which is 3.5 feet in diameter
and 17 feet deep? The air exchange rate is 16 air changes per hour.
.785 X 3.5 X 3.5 X 17 X 16 = ____________ CFH
280
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
39. Approximately how many feet of drop are in 455 feet of 8-inch sewer with a 0.0475 ft/ft.
slope?
40. How much brake horsepower is required to meet the following conditions: 250 gpm, total
head = 110 feet? The submersible pump that is being specified is a combined 64% efficient?
41. How wide is a trench at ground surface if a sewer trench is 2 feet wide at the bottom, 10
feet deep and the sides have been sloped at a 4/5 horizontal to 1 vertical (3/4:1) ratio?
42. A float arrives in a manhole 550 feet down stream three minutes and thirty seconds from its
release point. What is the velocity in ft/sec.?
Velocity ft/sec = distance time
Or
550 ft
210 sec
281
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
43. A new sewer line plan calls out a 0.6% slope of the line. An elevation reading of 108.8 feet
at the manhole discharge and an elevation of 106.2 feet at a distance of 200 feet from the
manhole are recorded. What is the existing slope of the line that has been installed?
44. A triangular pile of spoil is 12 feet high and 12 feet wide at the base. The pile is 60' long. If
the dump truck hauls 9 cubic yards of dirt, how many truck loads will it take to remove all of the
spoil?
Given the base and the height of a triangle, we can find the area. Given the area and either the base
or the height of a triangle, we can find the other dimension. The formula for area of a triangle is:
45. A red dye is poured into an upstream manhole connected to a 12 inch sewer. The dye first
appears in a manhole 400 feet downstream 3 minutes later. After 3 minutes and 40 seconds the
dye disappears. Estimate the flow velocity in feet per second?
282
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
46. Calculate the total dosage in pounds of a chemical. Assume the sewer is completely filled
with the concentration. Pipe diameter: 18 inches, Pipe length: 420 feet, Dose: 120 mg/L.
First .785 (1.5) (1.5) 420 X 7.48 =5549 convert to MGD .005549
Second
Flow (MGD) X Dose (mg/L) X 8.34 lbs/gal = Pounds per day formula =
.005549 X 120 X 8.34 = 5.55 lbs
283
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
284
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
References
"A High-Quality Digital X-Y Plotter Designed for Reliability, Flexibility and Low Cost". Hewlett-
Packard Journal. http://www.hpl.hp.com/hpjournal/pdfs/IssuePDFs/1979-02.pdf. Retrieved 9
February 2012.
"A.O.Smith: The AC's and DC's of Electric Motors" (PDF).
http://www.aosmithmotors.com/uploadedFiles/AC-DC%20manual.pdf. Retrieved 2009-12-07.
"Cobham plc :: Aerospace and Security, Aerospace Communications, Annemasse".
Cobham.com. 2011-02-13. http://www.cobham.com/about-cobham/aerospace-and-
security/about-us/aerospace-communications/annemasse.aspx.
"Encyclopdia Britannica, "Galileo Ferraris"".
http://www.britannica.com/EBchecked/topic/204963/Galileo-Ferraris.
"Frequently Asked Slip Ring Questions". Moog.com. 2009-06-23.
http://www.moog.com/products/slip-rings/slip-rings-faq-s/. Retrieved 2011-09-02.
"Galileo Ferraris". http://profiles.incredible-people.com/galileo-ferraris/.
"how slip rings work". Uea-inc.com. http://www.uea-inc.com/products/slip-rings/how-they-
work.aspx.
"Slip Ring Connector - SenRing Electronics". Senring.com. http://www.senring.com/hnr67.html.
Alan Hendrickson, Colin Buckhurst Mechanical design for the stage Focal Press, 2008 ISBN 0-
240-80631-X, page 379 with an illustration of pancake and drum-type slip rings.
B. R. Pelly, "Thyristor Phase-Controlled Converters and Cycloconverters: Operation, Control,
and Performance" (New York: John Wiley, 1971).
Bakshi U.A. and Bakshi V.U. Basics of Electrical Engineering. Technical Publications Pune. 2008.
Bakshi U.A., Godse and Bakshi M.V. Electrical Machines and Electronics. Technical Publications
Pune, 2009.
Bedford, B. D.; Hoft, R. G. et al. (1964). Principles of Inverter Circuits. New York: John Wiley &
Sons, Inc.. ISBN 0-471-06134-4. (Inverter circuits are used for variable-frequency motor speed
control)
Bishop, Robert H., Ed. The Mechatronics Handbook, ISAThe Instrumentation, Systems and
Automation Society, CRC Press, 2002.
Briere D. and Traverse, P. (1993) Airbus A320/A330/A340 Electrical Flight Controls: A Family
of Fault-Tolerant Systems Proc. FTCS, pp. 616623.
Brumbach Michael E. Industrial Electricity. Thomason Delmar Learning, 2005.
Cyril W. Lander, Power Electronics 3rd Edition, McGraw Hill International UK Limited, London
1993 ISBN 0-07-707714-8 Chapter 98 Slip Ring Induction Motor Control
Deshpande, M.V. Electric Motors: Application and Control. PHI Learning Private Ltd., 2010.
Deshpande, M.V. Electric Motors: Application and Control. PHI Learning Private Ltd., 2010.
Donald G. Fink and H. Wayne Beaty, Standard Handbook for Electrical Engineers, Eleventh
Edition, McGraw-Hill, New York, 1978, ISBN 0-07-020974-X.
Edwin J. Houston and Arthur Kennelly, Recent Types of Dynamo-Electric Machinery, copyright
American Technical Book Company 1897, published by P.F. Collier and Sons New York, 1902
Electric motors use 60% of china's electric energy, for example
Electricity and magnetism, translated from the French of Amde Guillemin. Rev. and ed. by
Silvanus P. Thompson. London, MacMillan, 1891
Faraday, Michael (1844). Experimental Researches in Electricity. 2. See plate 4.
Fitzgerald/Kingsley/Kusko (Fitzgerald/Kingsley/Umans in later years), Electric Machinery,
classic text for junior and senior electrical engineering students. Originally published in 1952,
6th edition published in 2002.
285
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Ganot's Physics, 14th Edition, N.Y., 1893 translated by Atkinson, pp. 907 and 908. (Section
899, and Figure 888).
Garrison, Ervan G., "A history of engineering and technology". CRC Press, 1998. ISBN 0-8493-
9810-X, 9780849398100. Retrieved May 7, 2009.
Gee, William (2004). "Sturgeon, William (17831850)". Oxford Dictionary of National Biography.
Oxford, England: Oxford University Press. doi:10.1093/ref:odnb/26748.
Gill, Paul. Electrical Power Equipment Maintenance and Testing. CRC Press: Taylor & Francis
Group, 2009.
Herman, Stephen L. Electric Motor Control. 9th ed. Delmar Cengage Learning, 2010.
Herman, Stephen L. Industrial Motor Control. 6th ed. Delmar Cengage Learning, 2010.
http://books.google.it/books?id=CxQdC6xPFSwC&pg=PA45&lpg=PA45&dq=GALILEO+FERRA
RIS+AC+MOTOR+INVENTION&source=web&ots=jjeS-hcv2T&sig=cYbNfNNeVwvMIhR-
JCP8uReedRU&hl=it&sa=X&oi=book_result&resnum=1&ct=result#v=onepage&q&f=false.
http://www.circuitcellar.com/ Motor Comparison, Circuit Cellar Magazine, July 2008, Issue 216,
Bachiochi, p.78 (Table edited in Wikipedia, May 2011)
http://www.daytronic.com/products/trans/t-magpickup.htm
http://www.electronicsweekly.com/Articles/2010/08/13/46377/dyson-vacuums-104000rpm-
brushless-dc-technology.htm
http://www.frankfurt.matav.hu/angol/magytud.htm
http://www.mpoweruk.com/history.htm
http://www.mpoweruk.com/timeline.htm
http://www.physics.umd.edu/lecdem/services/demos/demosk4/k4-21.gif
http://www.traveltohungary.com/english/articles/article.php?id=135
Hughes, Austin. Electric Motors and Drives: fundamentals, types and applications. 3rd ed. Linacre
House, 2006.
Irwin, David J., Ed. The Industrial Electronics Handbook. CRC Press: IEEE Press, 1997.
Jiles, David. Introduction to Magnetism and Magnetic Materials. CRC Press: Taylor Francis
Group, 1998.
John N. Chiasson, Modeling and High Performance Control of Electric Machines, Wiley-IEEE
Press, New York, 2005, ISBN 0-471-68449-X.
Kuphaldt, Tony R. (20002006). "Chapter 13 AC MOTORS". Lessons In Electric Circuits
Volume II. http://www.ibiblio.org/obp/electricCircuits/AC/AC_13.html. Retrieved 2006-04-11.
Laughton M.A. and Warne, D.F., Eds. Electrical Engineers Reference Book. 16th ed. Elsevier
Science, 2003.
linear Electric Machines- A Personal View - Eric R. Laithwaite, Proceedings of the IEEE, Vol. 63,
No. 2, February 1975 page 250
Miller, Rex and Mark R. Miller, Industrial Electricity and Motor Controls. McGraw Hill, 2008.
Nature 53. (printed in 1896) page: 516
Neidhfer, Gerhard. [http://www.ieee.org/organizations/pes/public/2007/sep/peshistory.html
"Early Three-Phase Power Winner in the development of polyphase ac"].
http://www.ieee.org/organizations/pes/public/2007/sep/peshistory.html.
North, David. (2000) "Finding Common Ground in Envelope Protection Systems". Aviation
Week & Space Technology, Aug 28, pp. 6668.
Pansini, Anthony, J (1989). Basic of Electric Motors. Pennwell Publishing Company. p. 45. ISBN
0-13-060070-9.
Patrick, Dale R. and Fardo, Stephen W. Electrical Distribution Systems. 2nd ed. The Fairmont
Press, 2009.
Patrick, Dale R. and Stephen W. Fardo. Rotating Electrical Machines and Power Systems. 2nd
ed. The Fairmont Press, 1997.
286
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
Patrick, Dale R; Fardo, Stephen W., Rotating Electrical Machines and Power Systems (2nd
Edition)1997 Fairmont Press, Inc. ISBN 978-0-88173-239-9 chapter 11
Peter W. Fortescue, John Stark, Graham Swinerd Spacecraft systems engineering John Wiley
and Sons, 2003 ISBN 0-470-85102-3
Rajput R.K. Basic Electrical and Electronics Engineering. Laxmi Publications Ltd., 2007.
Resenblat & Frienman DC and AC machinery
Schoenherr, Steven F. (2001), "Loudspeaker History". Recording Technology History. Retrieved
2010-03-13.
Shanefield D. J., Industrial Electronics for Engineers, Chemists, and Technicians, William
Andrew Publishing, Norwich, NY, 2001.
Singh,Yaduvir Dr. and Verma M. Fundamentals of Electrical Engineering. University Science
Press, 2010.
Sivanagaraju S., Reddy and Prasad. Power Semiconductor Drives. PHI Learning Private Ltd.,
2009.
Slow Speed Torque Drive Units
Subrahmanyam, V., Electric Drives: Concepts and Applications. 2nd ed. Tata McGraw Hill, 2011.
The Goodness of Small Contemporary Permanent Magnet Electric Machines - D J Patterson,
C W Brice, R A Dougal, D Kovuri
Tokai University Unveils 100W DC Motor with 96% Efficiency
http://techon.nikkeibp.co.jp/english/NEWS_EN/20090403/168295/
Toliyat, Hamid A. and Kliman G.B. Handbook of Electric Motors. Marcel Dekker, Inc., 2004.
US Department of Energy indicates over half US electricity generation is used by electric motors
Wayne Saslow. Electricity, Magnetism and Light. Thomson Learning Inc., 2002.
287
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com
We welcome you to complete the assignment in Microsoft Word. You can
easily find the assignment at www.abctlc.com. Once complete, just simply
fax or e-mail the answer key along with the registration page to us and allow
two weeks for grading. Once we grade it, we will mail a certificate of
completion to you.
Call us if you need any help. If you need your certificate back within 48
hours, you may be asked to pay a rush service fee of $50.00.
You can download the assignment in Microsoft Word from TLCs website
under the Assignment Page. www.abctlc.com
You will have 90 days in order to successfully complete this assignment with
a score of 70% or better. If you need any assistance, please contact TLCs
Student Services. Once you are finished, please mail, e-mail or fax your
answer sheet along with your registration form.
288
Hydraulic Principles Course 9/1/2016 (866) 557-1746 www.ABCTLC.com