Harris QCA 8e Experiments
Harris QCA 8e Experiments
Harris QCA 8e Experiments
To Accompany
Quantitative Chemical Analysis, 8th Edition (2010)
Daniel C. Harris
1
25. Measuring Manganese in Steel by Spectrophotometry with Standard Addition 95
26. Measuring Manganese in Steel by Atomic Absorption Using a Calibration Curve 99
27. Properties of an Ion-Exchange Resin 102
28. Analysis of Sulfur in Coal by Ion Chromatography 105
29. Measuring Carbon Monoxide in Automobile Exhaust by Gas Chromatography 107
30. Amino Acid Analysis by Capillary Electrophoresis 109
31. DNA Composition by High-Performance Liquid Chromatography 113
32. Analysis of Analgesic Tablets by High-Performance Liquid Chromatography 116
33. Anion Content of Drinking Water by Capillary Electrophoresis 118
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil 121
2
Experiments
Experiments described here illustrate major analytical techniques described in the textbook,
Quantitative Chemical Analysis. Procedures are organized roughly in the same order as topics in
the text. You are invited to download these instructions and reproduce them freely for use in
your laboratory. References to many additional experiments published in recent years in the
Journal of Chemical Education1 are listed at the web site where you found these experiments.
Some of the experiments refer to the availability of standards or unknowns from Thorn Smith.2
Although these procedures are safe when carried out with reasonable care, all chemical
experiments are potentially hazardous. Any solution that fumes (such as concentrated HCl), and
all nonaqueous solvents, should be handled in a fume hood. Pipetting should never be done by
mouth. Spills on your body should be flooded immediately with water and washed with soap
and water; your instructor should be notified for possible further action. Spills on the benchtop
should be cleaned immediately. Toxic chemicals should not be flushed down the drain. Your
instructor should establish a procedure for disposing of each chemical that you use.
When equipment permits, it is environmentally friendly and economical to reduce the
scale of an experiment. For example, 50-mL burets can be replaced by 10-mL burets at some
loss in analytical precision, but little educational loss. An even smaller scale is possible with
microburets made from 2-mL pipets.3 Micropipets and small volumetric flasks can replace large
glass pipets and large volumetric flasks (again at a sacrifice of precision). With properly chosen
electrodes, potentiometric titrations can be performed on a scale of a few milliliters, instead of
tens of milliliters, by using a syringe or a micropipet to deliver titrant. Instructions here were
written for the commonly available, large-size lab equipment, but your modification to a smaller
scale is encouraged.
1. You can search for experiments by key words in the index of the Journal of Chemical Education at
http://jchemed.chem.wisc.edu/
2. Thorn Smith Inc., www.thornsmithlabs.com. The following analyzed unknowns are available: Al-Mg alloy (for
Al, Mg), Al-Zn alloy (for Al, Zn), Sb ore (for Sb), brasses (for Sn, Cu, Pb, Zn), calcium carbonate (for Ca), cast
iron (for P, Mn, S, Si, C), cement (for Si, Fe, Al, Ca, Mg, S, ignition loss), Cr ore (for Cr), Cu ore (for Cu),
copper oxide (for Cu), ferrous ammonium sulfate (for Fe), Fe ore (for Fe), iron oxide (for Fe), limestone (for
Ca, Mg, Si, ignition loss), magnesium sulfate (for Mg), Mn ore (for Mn), Monel metal (for Si, Cu, Ni), nickel
silver (for Cu, Ni, Zn), nickel oxide (for Ni), phosphate rock (for P), potassium hydrogen phthalate (for H+),
silver alloys (for Ag, Cu, Zn, Ni), soda ash (for Na2CO3), soluble antimony (for Sb), soluble choride, soluble
oxalate, soluble phosphate, soluble sulfate, steels (for C, Mn, P, S, Si, Ni, Cr, Mo), Zn ore (for Zn). Primary
standards are also available: potassium hydrogen phthalate (to standardize NaOH), As2O3 (to standardize I2),
CaCO3 (to standardize EDTA), Fe(NH4)2(SO4)2 (to standardize dichromate or permanganate) , K2Cr2O7 (to
standardize thiosulfate), AgNO3, Na2CO3 (to standardize acid), NaCl (to standardize AgNO3), Na2C2O4 (to
standardize KMnO4).
3. M. M. Singh, C. McGowan, Z. Szafran, and R. M. Pike, J. Chem. Ed. 1998, 75, 371; ibid. 2000, 77, 625.
3
0. Green Analytical Chemistry Quantitative Chemical Analysis
In recent years, it has become a trend to develop items as green, with a perceived
environmental friendliness. The field known as green chemistry can be traced back to the
book Green Chemistry: Theory and Practice5 published in 1998 by Paul Anastas and John
Warner. They defined green chemistry as the use of a set of principles that reduces or
eliminates the use or generation of hazardous substances in the design, manufacture, and
application of chemical products. A key item to notice with this definition is that green
chemistry is a set of principles, that is, a way of thinking about chemistry. It is not a separate
chemical discipline like analytical, organic, or physical. In fact, it is hoped that the current
generation of chemistry students taking this course will have this mode of thinking become so
natural to them that we will no longer have to think about green chemistry, but just
chemistry.
How, then, does analytical chemistry fit into this way of thinking? What is green
analytical chemistry? To answer these questions, we must first reconsider what is analytical
chemistry and what is green chemistry.
During this course, you will learn a series of methods to qualitatively and quantitatively
characterize a sample or chemical system. Knowledge of these methods and the chemical
principles behind them is an asset valued by many industries. On the other hand, analytical
chemists may be viewed as a necessary evil, for example, to analyze samples in order to comply
with Food and Drug Administration or other regulatory agency requirements. Analytical
chemistry is something that is tolerated, but the analysis costs money, rather than adding to a
companys profits. Consider the following example: You work for a detergent manufacturer
and a product development chemist comes into your lab with a bottle of detergent, asking you to
determine the silicone level in this product. While you could easily do what you are told, upon
questioning you find out that the product development chemist really doesnt want to know the
silicone concentration. What he really wants to know is why the product isnt performing the
way it should (maybe it foams too much or doesnt clean effectively) and he thinks its related to
4. This section was contributed by Douglas E. Raynie, Department of Chemistry and Biochemistry, South Dakota
State University, Brookings SD 57007; douglas.raynie@sdstate.edu.
5. P. T. Anastas and J. C. Warner, Green Chemistry: Theory and Practice (New York: Oxford University Press,
1998).
4
0. Green Analytical Chemistry Quantitative Chemical Analysis
the silicone concentration. A good analytical chemist does not merely provide data, but rather
supplies information and knowledge upon which educated decisions can be based.
Analytical chemists are problem solvers. We use our knowledge to become partners with
our customers to answer their questions. In the detergent analysis example, one analytical
chemist might have run the silicone analysis and then several other analyses in order to
eventually solve the problem. But the analytical chemist who was a true scientific partner in the
process understood the problem and used his knowledge of chemistry to develop a more refined
hypothesis and streamline the analyses need to answer the ultimate question more easily. This
role of the analytical chemist was summarized by Prof. Herb Laitinin who editorialized,
Analysis of a sample is not the true aim of analytical chemistrythe real purpose of the
analysis is to solve a problem.6 Development of problem-solving skills comes with a
combination of analytical knowledge and experience. In summary, the analytical chemist is a
problem solver and solving problems involves a means of thinking about chemistry.
Weve defined green chemistry as something that is applied over the entire lifespan of a product.
Hidden within this definition is a combination of environmental and economic concerns. That is,
a product may have environmental benefits, but if it cannot compete in the marketplace, it is
doomed to failure. Green chemistry is guided by the set of 12 principles developed by Anastas
and Warner5 and shown in Table 1.
If green chemistry and concern for the environment are the right things to do, why
havent we been doing this all along? Think about organic chemistry. It isnt always easy to
choose the right reagents to put the correct functional groups in the right places for a complex
synthesis. Now consider that you are working as a product development chemist in industry.
Not only must you synthesize the compound with properties desired by your company, but you
must do it in a manner that can be passed on to a process engineer who can develop the process
with high yield, speed, safety, and minimal cost. Now add environmental concerns on top of all
of that and the lament of a certain amphibian character, Its not easy being green, becomes
more obvious. In summary, green chemistry involves a way of thinking about chemistry in an
environmentally and economically sound manner.
5
0. Green Analytical Chemistry Quantitative Chemical Analysis
1. Prevention
It is better to prevent waste than to treat or clean up waste after it has been created.
2. Atom Economy
Synthetic methods should be designed to maximize the incorporation of all materials used in
the process into the final product.
3. Less Hazardous Chemical Syntheses
Wherever practicable, synthetic methods should be designed to use and generate substances
that possess little or no toxicity to human health and the environment.
4. Designing Safer Chemicals
Chemical products should be designed to effect their desired function while minimizing their
toxicity.
5. Safer Solvents and Auxiliaries
The use of auxiliary substances (e.g., solvents, separation agents, etc.) should be made
unnecessary wherever possible and innocuous when used.
6. Design for Energy Efficiency
Energy requirements of chemical processes should be recognized for their environmental and
economic impacts and should be minimized. If possible, synthetic methods should be
conducted at ambient temperature and pressure.
7. Use of Renewable Feedstocks
A raw material or feedstock should be renewable rather than depleting whenever technically
and economically practicable.
8 Reduce Derivatives
Unnecessary derivatization (use of blocking groups, protection/ deprotection, temporary
modification of physical/chemical processes) should be minimized or avoided if possible,
because such steps require additional reagents and can generate waste.
9. Catalysis
Catalytic reagents (as selective as possible) are superior to stoichiometric reagents.
10. Design for Degradation
Chemical products should be designed so that at the end of their function they break down
into innocuous degradation products and do not persist in the environment.
11. Real-time analysis for Pollution Prevention
Analytical methodologies need to be further developed to allow for real-time, in-process
monitoring and control prior to the formation of hazardous substances.
12. Inherently Safer Chemistry for Accident Prevention
Substances and the form of a substance used in a chemical process should be chosen to
minimize the potential for chemical accidents, including releases, explosions, and fires.
6
0. Green Analytical Chemistry Quantitative Chemical Analysis
Reviewing the previous summary statement, we can correctly guess that green analytical
chemistry is a marriage of thought processes a unique way of thinking about how to do
chemistry. Performing chemical analyses in a green manner does not mean that we must make
compromises to the requisite accuracy, precision, and other analytical demands. Inserting green
values into the laboratory is about several factors related to the 12 green chemistry principles,
including waste, energy, toxicity, and others. For example, the hazard associated with a given
chemical is related to both our exposure to the chemical and the inherent risk possessed by the
chemical. While we can wear personal protective equipment, like safety glasses, lab coats, and
latex gloves, or work in a fume hood, we cannot change the inherent risk associated with a
compound. So perhaps we can change the reagent. Weve been doing this for years. Benzene
and carbon tetrachloride were banished from the lab since the mid-1970s. But our practices must
continue to evolve as our knowledge about chemicals and their inherent risk progresses.
At least half of the 12 principles of green chemistry apply to the analytical laboratory:
Principle 1: Prevent Waste. While the wastes generated in chemical production
overshadow the amount of waste coming from a typical analytical laboratory, individual
analytical procedures may involve as much as one liter of organic solvent to extract the analytes
from the sample. When used in an analytical procedure, even water, which everyone would
agree is an environmentally benign solvent, is converted to wastewater which must be treated
appropriately. So the professional analyst must stay abreast of developments that can minimize
waste generation.
Principle 5: Safer Solvents and Auxiliaries. The inherent risk associated with a chemical
must be considered and alternatives explored. The risk may be toxicological, but may also be
flammability, corrosivity, or other attributes. If alternatives do not exist, appropriate exposure
controls are needed.
Principle 6: Energy Efficiency. Several common analytical procedures can be considered
energy intensive. For example, not only are large amounts of solvents used in extractions, in
most cases the solvent must then be evaporated to concentrate the solutes for analysis.
Instrumental procedures can require high temperatures or have high power demands. Sometimes
trade-offs must be considered. Does it require less energy to keep a drying oven turned on
overnight and maintain a constant temperature or to turn off the oven and require a rapid heat up
just prior to use? If water is used as a nontoxic solvent, do we pay a price in the energy needed
7
0. Green Analytical Chemistry Quantitative Chemical Analysis
to evaporate water compared with many organic solvents? Later, we will present a set of metrics
to judge these compromises.
Principle 8: Reduce Derivatives. Many times chemical derivatives are employed to
enhance the solubility or detectability of sample components. For example, the determination of
fats in foods requires conversion of fatty acids into methyl esters for gas chromatography.
However, technological advances can provide similar analytical results while avoiding the need
for derivatization. For example, modern high-performance liquid chromatography can provide
results equivalent to previous generations of gas chromatography.
Principle 11: Real-time Analysis. This principle is analytical chemistry!!! The field of
process analytical chemistry, involving in-line, on-line, or at-line procedures, is a valuable tool
in chemical processing. By monitoring the creation of a by-product, the poisoning of a catalyst,
reaction pH, or other properties, feedback is provided to allow a reaction or process to stay in
control, avoiding potential process disruptions.
Principle 12: Safer Chemistry. The flammability of solvents, oxidative capability of
reagents, and similar factors should be considered in developing analytical methods.
Several of the experiments in this laboratory manual illustrate green chemistry. For
example, Experiment 11 (Kjeldahl Nitrogen Analysis) uses selenium-coated boiling chips as a
catalyst (Principle 9); Experiment 15 (Preparation and Iodometric Analysis of a High-
Temperature Semiconductor) reminds us that high-temperature superconductors could help us
toward energy sustainability (Principle 6); and Experiments 28 (Analysis of Sulfur in Coal by
Ion Chromatography) and 29 (Measuring Carbon Monoxide in Automobile Exhaust by Gas
Chromatography) illustrate the role of analytical chemistry in pollution prevention (Principles 1
and 11). A new experiment 34, Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon
Peel Oil, demonstrates the potential of new technology (supercritical fluid extraction) to address
solvent alternatives (Principles 1 and 5). We challenge students to discuss your experiments
relative to the 12 green chemistry principles as you write your reports.
Now that weve gotten some idea of what green analytical chemistry is, lets discuss
some specific green analytical considerations. Some review articles7,8,9 present more detailed
discussions of advances in the field of analytical chemistry that exhibit green chemistry
8
0. Green Analytical Chemistry Quantitative Chemical Analysis
attributes. However, general considerations for the practice of green analytical chemistry can be
summarized:
Planning. Proper planning allows the maximum amount of information to be obtained
from the minimal number of analyses. A branch of statistics called Design of Experiments can
be used to guide planning laboratory procedures. The developing field of chemometrics allows
us to uncover relationships between sample sets that might be hidden if conventional thinking is
used.
Sampling. Attention to proper sampling is an often overlooked portion of chemical
analysis, but perhaps the most important step in the entire analysis. A common misconception is
that an analytical method can be made green simply by being performed at the micro-scale.
While this is true, one must take care to ensure that the appropriate (minimum) sample size is
used. The sample must be collected to be statistically representative of the system under study
and homogenized to reduce error.
Direct Analysis. Methods which do not require sample work-up prior to the
measurement step have several advantages, including greenness. Techniques employing ion-
selective electrodes, reflectance spectroscopy, or surface analysis can often provide chemical
information without using additional analytical reagents.
Sample Preparation. Organic extractions and acid digestions generate the greatest
amount of waste (while using hazardous solvents or acids) in many procedures. This field has
received considerable attention in modern times. Acid digestions can be made safer through the
application of microwave irradiation. Alternative solvent processes using water, ionic liquids, or
careful manipulation of heat and energy can greatly enhance the sample preparation process.
Chromatography. Separation of analyte from other sample components is necessary in
most analytical procedures. Chromatography can involve copious amounts of solvents, sorbents,
and other chemicals. Microcolumn chromatography reduces solvent consumption, minimizes
the use of chromatographic sorbents, and provides superior performance.
Data Reduction. Statistical manipulations can mine information from analytical results.
Many times unambiguous compound identification is not needed; rather knowledge of trends is
sufficient.
Field Analysis and Process Analysis. Taking the analysis to the sample generally
provides several green advantages. Near instantaneous feedback can minimize the likelihood of
a process upset. Similarly, the backhoe operator at an environmental clean-up site would like
9
0. Green Analytical Chemistry Quantitative Chemical Analysis
instantaneous notification that the site is clean so she can quit digging, rather than waiting for
results to come back from the laboratory. One contribution of analytical chemistry to the
environmental movement has been the identification of hazards within the environment. Careful
execution of field and process analysis may advance analytical chemistry from an identification
and compliance model to a hazard prevention model.
A good place to start is to compare an analytical method against the 12 principles of green
chemistry. However, keep in mind that compromises are made along the way. One method
might use less solvent, while another is less energy intensive. No procedure is truly green;
rather, one method may be considered greener than another.
One set of metrics used to assess the green profile of a method is associated with the
National Environmental Monitoring Index (NEMI) database (www.nemi.gov). The NEMI
database was compiled by researchers from several federal agencies, the American Chemical
Society Green Chemistry Institute, and others. This free, on-line database lists regulatory and
nonregulatory methods and procedures for analysis of water, sediment, air, and tissues. It
presents information on cost and performance of each method. Presented with each method is a
green profile, developed in collaboration with 25 environmental methods experts from five
regulatory agencies and private labs. An example of this profile is shown in Figure 1 for the
Environmental Protection Agency method for the determination of total water hardness by
EDTA titration (similar to Experiment 12).
The symbol for the green profile is simple, visual, and allows an individual to make a
value judgment against the profile criteria. Heres a description of the symbol criteria:
Hazardous: A method fails this criterion if it uses chemicals in either of two important
databases, the Resource Conservation and Recovery Act D, F, P, or U lists10 or the
10. http://ecfr.gpoaccess.gov/cgi/t/text/textidx?c=ecfr;sid=4990e762d7b81851bef18f82dc851826;rgn=div5;
view=text;node=40%3A25.0.1.1.2;idno=40;cc=ecfr#40:25.0.1.1.2.4.1.2
10
0. Green Analytical Chemistry Quantitative Chemical Analysis
Environmental Protection Agency Toxic Release Inventory.11 About half of the methods in the
NEMI database fail this criterion.
Waste Amount: A method fails this criterion if the amount of waste generated is greater
than 50 grams. This 50 grams includes the mass of sample, as well as all chemicals used in the
procedure, but does not include calibration standards, cleaning (unless significant amounts of
chemicals are stipulated in cleaning steps), and related factors. The waste criterion is perhaps
the most rigorous. When applied to 560 methods on the NEMI database, approximately 2/3
failed this criterion. Failures generally were due to solvent use for organic analysis and mineral
acid use for inorganics.
Corrosive: A method fails this criterion if the pH during the analysis is less than 2 or
greater than 12. The failure rate for this criterion was about 20% for the NEMI methods.
PBT (Persistent, Bioaccumulative, or Toxic): A method fails this criterion if it uses
chemicals considered to be persistent in the environment, bioaccumulative, or toxic as defined
by the EPA Toxic Release Inventory. Only about 5% of the NEMI methods did not meet this
criterion and each of the methods that failed the PBT criterion also failed for hazard. Most
commonly, these methods included lead or mercury compounds.
For the EPA water hardness method (EPA Method 130.2) illustrated in Figure 1, we see
that the method is considered green by hazard and PBT criteria, but not by waste and corrosion
criteria. During the analysis, the pH is less than 2 and 66 grams of waste are generated.
Summary
Both analytical chemistry and green chemistry are based on a way of thinking about how you
perform experiments. Green analytical chemistry is a convergence of these thought processes.
Good analytical chemistry is inherently green chemistry.
For each experiment in this laboratory manual, a green profile is displayed. A suggested
component of your report should be a discussion of why a particular experiment met or failed the
individual green profile criteria. Suggest ways that the experiment may be made greener. If you
follow through with this exercise, these thought processes should become increasingly natural to
you. If you develop this mode of thinking so that it becomes second nature, you will be poised
to take on leadership responsibilities in your generation of professional chemists.
11. http://www.epa.gov/tri/chemical/
11
1. Calibration of Volumetric Glassware Quantitative Chemical Analysis
An important trait of a good analyst is the ability to extract the best possible
data from his or her equipment. For this purpose, it is desirable to calibrate
your own volumetric glassware (burets, pipets, flasks, etc.) to measure the
exact volumes delivered or contained. This experiment also promotes
Green Profile improved technique in handling volumetric glassware.
See Section 0
This procedure tells how to construct a calibration graph such as the one below to convert the
measured volume delivered by a buret to the true volume delivered at 20C.
1. Fill the buret with distilled water and force any air bubbles out the tip. See whether the
buret drains without leaving drops on its walls. If drops are left, clean the buret with soap
and water or soak it with cleaning solution.12 Adjust the meniscus to be at or slightly below
0.00 mL, and touch the buret tip to a beaker to remove the suspended drop of water. Allow
the buret to stand for 5 min while you weigh a 125-mL flask fitted with a rubber stopper.
(Hold the flask with a paper towel to prevent fingerprints from changing its mass.) If the
12. Prepare cleaning solution by dissolving 36 g of ammonium peroxydisulfate, (NH4)2S2O8, in a loosely stoppered
2.2-L (one gallon) bottle of 98 wt% sulfuric acid. Add ammonium peroxydisulfate every few weeks to
maintain the oxidizing strength. EOSULF is an alternative cleaning solution for removing proteins and other
residues from glassware in a biochemistry lab. EOSULF contains the metal binder EDTA and a sulfonate
detergent. It can be safely poured down the drain. [P. L. Manske, T. M. Stimpfel, and E. L. Gershey, J. Chem.
Ed. 1990, 67, A280.]
12
1. Calibration of Volumetric Glassware Quantitative Chemical Analysis
level of the liquid in the buret has changed, tighten the stopcock and repeat the procedure.
Record the level of the liquid.
2. Drain approximately 10 mL of water at a rate < 20 mL/min into the weighed flask, and cap it
tightly to prevent evaporation. Allow 30 s for the film of liquid on the walls to descend
before you read the buret. Estimate all readings to the nearest 0.01 mL. Weigh the flask
again to determine the mass of water delivered.
3. Drain the buret from 10 to 20 mL, and measure the mass of water delivered. Repeat the
procedure for 30, 40, and 50 mL. Then do the entire procedure (10, 20, 30, 40, 50 mL) a
second time.
4. Use the table of water density at the end of this experiment to convert the mass of water to
the volume delivered. Repeat any set of duplicate buret corrections that do not agree to
within 0.04 mL. Prepare a calibration graph like the one above, showing the correction
factor at each 10-mL interval.
When draining the buret at 24C, you observe the following values:
To calculate the actual volume delivered when 9.984 g of water is delivered at 24C, use
the conversion factor 1.003 8 mL/g in the table of water density. We find that 9.984 g occupies
(9.984 g)(1.003 8 mL/g) = 10.02 mL. The average correction for both sets of data is +0.045 mL.
13
1. Calibration of Volumetric Glassware Quantitative Chemical Analysis
To obtain the correction for a volume greater than 10 mL, add successive masses of water
collected in the flask. Suppose that the following masses were measured:
0.0310.01 9.984
10.0119.90 9.835
19.9030.06 10.071
Sum 30.03 mL 29.890 g
The total volume of water delivered is (29.890 g)(1.003 8 mL/g) = 30.00 mL. Because the
indicated volume is 30.03 mL, the buret correction at 30 mL is 0.03 mL.
What does this mean? Suppose that the calibration graph shown above applies to your
buret. If you begin a titration at 0.04 mL and end at 29.00 mL, you would deliver 28.96 mL if
the buret were perfect. The calibration graph tells you that the buret delivers 0.03 mL less than
the indicated amount; so only 28.93 mL was actually delivered. To use the calibration curve,
either begin all titrations near 0.00 mL or correct both the initial and the final readings. Use the
calibration curve whenever you use your buret.
Other volumetric glassware can also be calibrated by measuring the mass of water they
contain or deliver. Glass transfer pipets and plastic micropipets can be calibrated by weighing
the water delivered from them. A volumetric flask can be calibrated by weighing it empty and
then weighing it filled to the mark with distilled water. Perform each procedure at least twice.
Compare your results with the tolerances listed in tables in Chapter 2 of the textbook.
14
1. Calibration of Volumetric Glassware Quantitative Chemical Analysis
Density of water
15
2. Gravimetric Determination of Calcium as CaC2O4 . H2O Quantitative Chemical Analysis
Reagents
Procedure
16
2. Gravimetric Determination of Calcium as CaC2O4 . H2O Quantitative Chemical Analysis
cooldown after each cycle).14 You will need to experiment with your oven to find
appropriate heating times.
2. Use a few small portions of unknown to rinse a 25-mL transfer pipet, and discard the
washings. Use a rubber bulb, not your mouth, to provide suction. Transfer exactly 25 mL of
unknown to each of three 250- to 400-mL beakers, and dilute each with ~75 mL of 0.1 M
HCl. Add 5 drops of methyl red indicator solution to each beaker. This indicator is red
below pH 4.8 and yellow above pH 6.0.
3. Add ~25 mL of ammonium oxalate solution to each beaker while stirring with a glass rod.
Remove the rod and rinse it into the beaker with small portions of distilled water. Add ~15 g
of solid urea to each sample, cover it with a watchglass, and boil gently for ~30 min until the
indicator turns yellow.
4. Filter each hot solution through a weighed funnel, using suction (Figure 2-17 in the
textbook). Add ~3 mL of ice-cold water to the beaker, and use a rubber policeman to help
transfer the remaining solid to the funnel. Repeat this procedure with small portions of ice-
cold water until all of the precipitate has been transferred to the funnel. Finally, use two
10-mL portions of ice-cold water to rinse each beaker, and pour the washings over the
precipitate.
5. Dry the precipitate, first with aspirator suction for 1 min, then in an oven at 105C for 12 h.
Bring each filter to constant mass. The product is somewhat hygroscopic, so only one filter
at a time should be removed from the desiccator, and weighings should be done rapidly.
Alternatively, the precipitate can be dried in a microwave oven once for 4 min, followed by
several 2-min periods, with cooling for 15 min before weighing. This drying procedure does
not remove the water of crystallization.
6. Calculate the average molarity of Ca2+ in the unknown solution or the average weight
percent of Ca in the unknown solid. Report the standard deviation and relative standard
deviation (s / x = standard deviation/average).
17
3. Gravimetric Determination of Iron as Fe2O3 Quantitative Chemical Analysis
Base
Fe3+ + (2 + x)H2O FeOOH . xH2O(s) + 3H+
Hydrous ferric oxide
Green Profile
See Section 0 900C
FeOOH . xH2O Fe2O3(s)
The gelatinous hydrous oxide can occlude impurities. Therefore, the initial precipitate is
dissolved in acid and reprecipitated. Because the concentration of impurities is lower during the
second precipitation, occlusion is diminished. Solid unknowns can be prepared from reagent
ferrous ammonium sulfate or purchased from Thorn Smith.2
Procedure
1. Bring three porcelain crucibles and caps to constant mass by heating to redness for 15 min
over a burner (Figure 1). Cool for 30 min in a desiccator and weigh each crucible. Repeat
this procedure until successive weighings agree within 0.3 mg. Be sure that all oxidizable
substances on the entire surface of each crucible have burned off.
15. D. A. Skoog and D. M. West, Fundamentals of Analytical Chemistry, 3d ed. (New York: Holt, Rinehart and
Winston, 1976).
18
3. Gravimetric Determination of Iron as Fe2O3 Quantitative Chemical Analysis
16. Basic reagents should not be stored in glass bottles because they slowly dissolve glass. If ammonia from a
glass bottle is used, it may contain silica particles and should be freshly filtered.
19
3. Gravimetric Determination of Iron as Fe2O3 Quantitative Chemical Analysis
7. Dry the crucible cautiously with a small flame, as shown in Figure 1. The flame should be
directed at the top of the container, and the lid should be off. Avoid spattering. After the
filter paper and precipitate are dry, char the filter paper by increasing the flame temperature.
The crucible should have free access to air to avoid reduction of iron by carbon. (The lid
should be kept handy to smother the crucible if the paper inflames.) Any carbon left on the
crucible or lid should be burned away by directing the burner flame at it. Use tongs to
manipulate the crucible. Finally, ignite the product for 15 min with the full heat of the
burner directed at the base of the crucible where the Fe2O3 is located.
8. Cool the crucible briefly in air and then in a desiccator for 30 min. Weigh the crucible and
the lid, reignite, and bring to constant mass (within 0.3 mg) with repeated heatings.
9. Calculate the weight percent of iron in each sample, the average, the standard deviation, and
the relative standard deviation (s/ x ).
20
4. Penny Statistics Quantitative Chemical Analysis
4. Penny Statistics17
U.S. pennies minted after 1982 have a Zn core with a Cu overlayer. Prior to
1982, pennies were made of brass, with a uniform composition (95 wt% Cu /
5 wt% Zn). In 1982, both the heavier brass coins and the lighter zinc coins
were made. In this experiment, your class will weigh many coins and pool
the data to answer the following questions: (1) Do pennies from different
Green Profile
See Section 0 years have the same mass? (2) Do pennies from different mints have the
same mass? (3) Do the masses follow a Gaussian distribution?
Gathering Data
Each student should collect and weigh enough pennies to the nearest milligram to provide a data
set for the entire class containing 300 to 500 brass coins and a similar number of zinc coins.
Instructions are given for a spreadsheet, but the same operations can be carried out with a
calculator. Compile all the class data in a spreadsheet. Each column should list the masses of
pennies from only one calendar year. Use the spreadsheet sort function to sort each column so
that the lightest mass is at the top of the column and the heaviest is at the bottom. (To sort a
column, click on the column heading to select the entire column, go to the DATA menu, select the
SORT tool, and follow the directions that come up.) There will be two columns for 1982, in
which both types of coins were made. Select a year other than 1982 for which you have many
coins and divide the coins into those made in Denver (with a D beneath the year) and those
minted in Philadelphia (with no mark beneath the year).
Discrepant Data
At the bottom of each column, compute the mean and standard deviation. Retain at least one
extra digit beyond the milligram place to avoid round-off errors in your calculations.
Damaged or corroded coins may have masses different from those of the general
population. Discard grossly discrepant masses lying 4 standard deviations from the mean in
any one year. (For example, if one column has an average mass of 3.000 g and a standard
deviation of 0.030 g, the 4-standard-deviation limit is (4 0.030) = 0.120 g. A mass that is
17. T. H. Richardson, J. Chem. Ed. 1991, 68, 310. In a related experiment, students measure the mass of copper in
the penny as a function of the year of minting: R. J. Stolzberg, J. Chem. Ed. 1998, 75, 1453.
21
4. Penny Statistics Quantitative Chemical Analysis
2.880 or 3.120 g should be discarded.) After rejecting discrepant data, recompute the average
and standard deviation for each column.
Select the two years (1982) in which the zinc coins have the highest and lowest average
masses. For each of the two years, compute the 95% confidence interval. Use the t test to
compare the two mean values at the 95% confidence level. Are the two average masses
significantly different? Try the same for two years of brass coins ( 1982). Try the same for the
one year whose coins you segregated into those from Philadelphia and those from Denver. Do
the two mints produce coins with the same mass?
Distribution of Masses
List the masses of all pennies made in or after 1983 in a single column, sorted from lowest to
highest mass. There should be at least 300 masses listed. Divide the data into 0.01-g intervals
(e.g., 2.480 to 2.489 g) and prepare a bar graph, like that shown in Figure 1. Find the mean (x- ),
median, and standard deviation (s) for all coins in the graph. For random (Gaussian) data, only 3
out of 1 000 measurements should lie outside of x- 3s. Indicate which bars (if any) lie beyond
3s. In Figure 1 two bars at the right are outside of x- 3s.
Prepare a graph like Figure 2 in which the ordinate (y-axis) is the mass of zinc pennies minted
each year since 1982 and the abscissa (x-axis) is the year. For simplicity, let 1982 be year 1,
1983 be year 2, and so on. If the mass of a penny increases systematically from year to year,
then the least-squares line through the data will have a positive slope. If the mass decreases, the
slope will be negative. If the mass is constant, the slope will be 0. Even if the mass is really
constant, your selection of coins is random and the slope is not exactly 0.
We want to know whether the slope is significantly different from zero. Suppose that
you have data for 14 years. Enter all of the data into two columns of the least-squares
spreadsheet in Figure 4-9 in the textbook. Column B (xi) is the year (1 to 14) and column C (yi)
is the mass of each penny. Your table will have several hundred entries. If you are not using a
22
4. Penny Statistics Quantitative Chemical Analysis
95
100
Data for 613 Composite
Pennies (1982-1992)
83
Average = 2.507 g
75
Standard Deviation = 0.031 g
80
Median = 2.506 g
69
65
Calculated Gaussian Curve
Number of Coins
60 Observed Number
48
40
31
29
26
3 Standard
24
Deviation
Limit
18
20
12
10
9
4
4
3
3
1
1
0
2.415
2.425
2.435
2.445
2.455
2.465
2.475
2.485
2.495
2.505
2.515
2.525
2.535
2.545
2.555
2.565
2.575
2.585
2.595
2.605
2.615
Mass (g)
Figure 1. Distribution of penny masses from the years 1982 to 1992 measured in Dan's house
by Jimmy Kusznir and Doug Harris in December 1992.
spreadsheet, just tabulate the average mass for each year. Your table will have only 14 entries.
Calculate the slope (m) and intercept (b) of the best straight line through all points and find the
uncertainties in slope (sm) and intercept (sb).
Use Student's t to find the 95% confidence interval for the slope:
where Students t is for n 2 degrees of freedom. For example, if you have n = 300 pennies,
n 2 = 298, and it would be reasonable to use the value of t (= 1.960) at the bottom of the table
for n = . If the least-squares slope is m sm = 2.78 0.40 mg/year, then the 95% confidence
interval is m tsm = 2.78 (1.960)(0.40) = 2.78 0.78 mg/year.
23
4. Penny Statistics Quantitative Chemical Analysis
2.65
2.60
2.6
2.55
Mass (g)
2.50
2.5
1992
2.45
1982
2.40
2.4
0 2 4 6 8 10 12
Year
Figure 2. Penny mass versus year for 612 coins. Because the slope of the least-squares line is
significantly less than 0, we conclude that the average mass of older pennies is greater than the
average mass of newer pennies.
The 95% confidence interval is 2.78 0.78 = 3.56 to 2.00 mg/year. We are 95%
confident that the true slope is in this range and is, therefore, not 0. We conclude that older zinc
pennies are heavier than newer zinc pennies.
The smooth Gaussian curve superimposed on the data in Figure 1 was calculated from the
formula
24
4. Penny Statistics Quantitative Chemical Analysis
Now we carry out a 2 test (pronounced ki squared) to see if the observed distribution
(the bars in Figure 1) agrees with the Gaussian curve. The statistic 2 is given by
(yobs ycalc)2
2 = ycalc (3)
where yobs is the height of a bar on the chart, ycalc is the ordinate of the Gaussian curve
(Equation 2), and the sum extends over all bars in the graph. Calculations for the data in
Figure 1 are shown in Table 1.
Observed Calculated
number ordinate of
Mass (g) of coins Gaussian curve
(yobs ycalc)2
(x) (yobs) (ycalc) yobs ycalc ycalc
25
4. Penny Statistics Quantitative Chemical Analysis
*Example: The value of 2 from 15 observations is 17.2. This value is less than 23.7 listed for 14 (= 15 1)
degrees of freedom. Because 2 does not exceed the critical value, the observed distribution is consistent with the
theoretical distribution.
At the bottom of Table 1 we see that 2 for all 21 bars is 43.231. In Table 2 we find a
critical value of 31.4 for 20 degrees of freedom (degrees of freedom = one less than number of
categories). Because 2 from Equation 3 exceeds the critical value, we conclude that the
distribution is not Gaussian.
It would be reasonable to omit the smallest bars at the edge of the graph from the
calculation of 2 because these bars contain the fewest observations but make large contributions
to 2. Suppose that we reject bars lying >3 standard deviations from the mean. This removes
the two bars at the right side of Figure 1 which give the last two entries in Table 1. Omitting
these two points gives 2 = 30.277, which is still greater than the critical value of 28.9 for 18
degrees of freedom in Table 2. Our conclusion is that at the 95% confidence level the observed
distribution in Figure 1 is not quite Gaussian. It is possible that exceptionally light coins are
nicked and exceptionally heavy coins are dirty or corroded. You would need to inspect these
coins to verify this hypothesis.
26
4. Penny Statistics Quantitative Chemical Analysis
Gathering data:
1. Attach a table of masses, with one column sorted by mass for each year.
2. Divide 1982 into two columns, one for light (zinc) and one for heavy (brass) pennies.
3. One year should be divided into one column from Denver and one from Philadelphia.
Discrepant data:
1. List the mean (x- ) and standard deviation (s) for each column.
2. Discard data that lie outside of x- 4s and recompute x- and s.
Confidence intervals and t test:
1. For the year 1982 with highest average mass:
95% confidence interval (= x- ts/ n ) = _______________
For the year 1982 with lowest average mass:
95% confidence interval = _______________
Comparison of means with t-test:
tcalculated = __________
ttable = ____________
Is the difference significant? _____________
2. For the year 1982 with highest average mass:
95% confidence interval = _______________
For the year 1982 with lowest average mass:
95% confidence interval = _______________
Comparison of means with t test:
tcalculated = __________
ttable = ____________
Is the difference significant? _____________
3. For Philadelphia versus Denver coins in one year:
Philadelphia 95% confidence interval = _______________
Denver 95% confidence interval = _______________
Comparison of means with t test:
tcalculated = __________
ttable = ____________
Is the difference significant? _____________
27
4. Penny Statistics Quantitative Chemical Analysis
28
5. Statistical Evaluation of Acid-Base Indicators Quantitative Chemical Analysis
This experiment introduces you to the use of indicators and to the statistical
concepts of mean, standard deviation, Q test, and t test. You will compare
the accuracy of different indicators in locating the end point in the titration of
the base tris with hydrochloric acid:
Green Profile
See Section 0
(HOCH2)3CNH2 + H+ (HOCH2)3CNH+3
Tris(hydroxymethyl)aminomethane
tris
Reagents
~0.1 M HCl: Each student needs ~500 mL of unstandardized solution, all from a single batch
that will be analyzed by the whole class.
Tris: Solid, primary standard powder should be available (~4 g/student).
Indicators should be available in dropper bottles:
Bromothymol blue (BB): Dissolve 0.100 g in 16.0 mL 0.010 0 M NaOH and add 225 mL H2O
Methyl red (MR): Dissolve 20 mg in 60 mL of ethanol and add 40 mL H2O
Bromocresol green (BG): Dissolve 0.100 g in 14.3 mL 0.010 0 M NaOH and add 225 mL
H2O
Methyl orange (MO): Dissolve 10 mg in 100 mL H2O
Erythrosine (E): Dissolve 100 mg disodium erythrosine in 100 mL H2O
Color changes to use for the titration of tris with HCl are
BB: blue (pH 7.6) yellow (pH 6.0) (end point is disappearance of green)
MR: yellow (pH 6.0) red (pH 4.8) (end point is disappearance of orange)
BG: blue (pH 5.4) yellow (pH 3.8) (end point is green)
MO: yellow (pH 4.4) red (pH 3.1) (end point is first appearance of orange)
E: red (pH 3.6) orange (pH 2.2) (end point is first appearance of orange)
Procedure
Each student should perform the following procedure with one indicator. Different students
should be assigned different indicators so that at least four students evaluate each indicator.
29
5. Statistical Evaluation of Acid-Base Indicators Quantitative Chemical Analysis
1. Calculate the molecular mass of tris and the mass required to react with 35 mL of 0.10 M
HCl. Weigh this much tris into a 125-mL flask.
2. It is good practice to rinse a buret with a new solution to wash away traces of previous
reagents. Wash your 50-mL buret with three 10-mL portions of 0.1 M HCl and discard the
washings. Tilt and rotate the buret so that the liquid washes the walls, and drain the liquid
through the stopcock. Then fill the buret with 0.1 M HCl to near the 0-mL mark, allow a
minute for the liquid to settle, and record the reading to the nearest 0.01 mL.
3. The first titration will be rapid, to allow you to find the approximate end point of the
titration. Add ~20 mL of HCl from the buret to the flask and swirl to dissolve the tris. Add
24 drops of indicator and titrate with ~1-mL aliquots of HCl to find the end point.
4. From the first titration, calculate how much tris is required to cause each succeeding titration
to require 3540 mL of HCl. Weigh this much tris into a clean flask. Refill your buret to
near 0 mL and record the reading. Repeat the titration in step 3, but use 1 drop at a time near
the end point. When you are very near the end point, use less than a drop at a time. To do
this, carefully suspend a fraction of a drop from the buret tip and touch it to the inside wall of
the flask. Carefully tilt the flask so that the bulk solution overtakes the droplet and then swirl
the flask to mix the solution. Record the total volume of HCl required to reach the end point
to the nearest 0.01 mL. Calculate the true mass of tris with the buoyancy equation 2-1 in the
textbook (density of tris = 1.327 g/mL). Calculate the molarity of HCl.
5. Repeat the titration to obtain at least six accurate measurements of the HCl molarity.
6. Use the Grubbs test in Section 4-6 in the textbook to decide whether any results should be
discarded. Report your retained values, their mean, their standard deviation, and the relative
standard deviation (s/ x ).
Data Analysis
Pool the data from your class to fill in Table 1, which shows two possible results. The quantity
sx is the standard deviation of all results reported by many students. The pooled standard
deviation, sp, is derived from the standard deviations reported by each student. If two students
see the end point differently, each result might be very reproducible, but the reported molarities
will be different. Together, they will generate a large value of sx (because their results are so
different), but a small value of sp (because each one was reproducible).
30
5. Statistical Evaluation of Acid-Base Indicators Quantitative Chemical Analysis
where there is one term in the numerator for each student using that indicator.
Select the pair of indicators giving average HCl molarities that are farthest apart. Use the
t test (Equation 4-8 in the textbook) to decide whether the average molarities are significantly
different from each other at the 95% confidence level. When you calculate the pooled standard
deviation for Equation 4-8, the values of s1 and s2 in Equation 4-9 in the textbook are the values
of sx (not sp) in Table 1.
A condition for using Equations 4-8 and 4-9 is that the standard deviations for the two
sets of measurements should not be significantly different from each other. The F test tells us
whether two standard deviations are significantly different from each other. F is the quotient
of the squares of the standard deviations:
s21
Fcalculated = 2 (1)
s2
We always put the larger standard deviation in the numerator so that F 1. If Fcalculated > Ftable
in Table 2, then the difference is significant.
Use the F test in Equation 1 to decide whether or not the standard deviations for the two
indicators giving the largest difference in mean HCl molarity are significantly different. If they
are significantly different, use Equations 4-8a and 4-9a of the textbook for the t test.
31
5. Statistical Evaluation of Acid-Base Indicators Quantitative Chemical Analysis
2 19.0 19.2 19.2 19.3 19.3 19.4 19.4 19.4 19.4 19.4 19.4 19.4 19.5 19.5
3 9.55 9.28 9.12 9.01 8.94 8.89 8.84 8.81 8.79 8.74 8.70 8.66 8.62 8.53
4 6.94 6.59 6.39 6.26 6.16 6.09 6.04 6.00 5.96 5.91 5.86 5.80 5.75 5.63
5 5.79 5.41 5.19 5.05 4.95 4.88 4.82 4.77 4.74 4.68 4.62 4.56 4.50 4.36
6 5.14 4.76 4.53 4.39 4.28 4.21 4.15 4.10 4.06 4.00 3.94 3.87 3.81 3.67
7 4.74 4.35 4.12 3.97 3.87 3.79 3.73 3.68 3.64 3.58 3.51 3.44 3.38 3.23
8 4.46 4.07 3.84 3.69 3.58 3.50 3.44 3.39 3.35 3.28 3.22 3.15 3.08 2.93
9 4.26 3.86 3.63 3.48 3.37 3.29 3.23 3.18 3.14 3.07 3.01 2.94 2.86 2.71
10 4.10 3.71 3.48 3.33 3.22 3.14 3.07 3.02 2.98 2.91 2.84 2.77 2.70 2.54
11 3.98 3.59 3.36 3.20 3.10 3.01 2.95 2.90 2.85 2.79 2.72 2.65 2.57 2.40
12 3.88 3.49 3.26 3.11 3.00 2.91 2.85 2.80 2.75 2.69 2.62 2.54 2.47 2.30
13 3.81 3.41 3.18 3.02 2.92 2.83 2.77 2.71 2.67 2.60 2.53 2.46 2.38 2.21
14 3.74 3.34 3.11 2.96 2.85 2.76 2.70 2.65 2.60 2.53 2.46 2.39 2.31 2.13
15 3.68 3.29 3.06 2.90 2.79 2.71 2.64 2.59 2.54 2.48 2.40 2.33 2.25 2.07
16 3.63 3.24 3.01 2.85 2.74 2.66 2.59 2.54 2.49 2.42 2.35 2.28 2.19 2.01
17 3.59 3.20 2.96 2.81 2.70 2.61 2.55 2.49 2.45 2.38 2.31 2.23 2.15 1.96
18 3.56 3.16 2.93 2.77 2.66 2.58 2.51 2.46 2.41 2.34 2.27 2.19 2.11 1.92
19 3.52 3.13 2.90 2.74 2.63 2.54 2.48 2.42 2.38 2.31 2.23 2.16 2.07 1.88
20 3.49 3.10 2.87 2.71 2.60 2.51 2.45 2.39 2.35 2.28 2.20 2.12 2.04 1.84
30 3.32 2.92 2.69 2.53 2.42 2.33 2.27 2.21 2.16 2.09 2.01 1.93 1.84 1.62
3.00 2.60 2.37 2.21 2.10 2.01 1.94 1.88 1.83 1.75 1.67 1.57 1.46 1.00
32
5. Statistical Evaluation of Acid-Base Indicators Quantitative Chemical Analysis
Select the pair of indicators giving the second most different molarities in Table 1 and
use the t test again to see whether or not this second pair of results is significantly different.
On the basis of the Q test, should any molarity be discarded? If so, which one?
Mean value of retained results:
Standard deviation:
Relative standard deviation (%):
Pooled Class Data
1. Attach your copy of Table 1 with all entries filled in.
2. Compare the two most different molarities in Table 1. (Show your F and t tests and state
your conclusion.)
3. Compare the two second most different molarities in Table 1.
33
6. Preparing Standard Acid and Base Quantitative Chemical Analysis
Reagents
Standardizing NaOH
1. Dry primary standard grade potassium hydrogen phthalate for 1 h at 105C and store
it in a capped bottle in a desiccator.
34
6. Preparing Standard Acid and Base Quantitative Chemical Analysis
2. Boil 1 L of distilled water for 5 min to expel CO2. Pour the water into a polyethylene
bottle, which should be tightly capped whenever possible. Calculate the volume of
50 wt% NaOH needed to prepare 1 L of 0.1 M NaOH. (The density of 50 wt%
NaOH is 1.50 g per milliliter of solution.) Use a graduated cylinder to transfer this
much NaOH to the bottle of water. (CAUTION: 50 wt% NaOH eats people. Flood
any spills on your skin with water.) Mix well and cool the solution to room
temperature (preferably overnight).
3. Weigh four samples of solid potassium hydrogen phthalate and dissolve each in ~25
mL of distilled water in a 125-mL flask. Each sample should contain enough solid to
react with ~25 mL of 0.1 M NaOH. Add 3 drops of phenolphthalein to each flask and
titrate one rapidly to find the end point. The buret should have a loosely fitted cap to
minimize entry of CO2 from the air.
4. Calculate the volume of NaOH required for each of the other three samples and titrate
them carefully. During each titration, periodically tilt and rotate the flask to wash all
liquid from the walls into the bulk solution. Near the end, deliver less than 1 drop of
titrant at a time. To do so, carefully suspend a fraction of a drop from the buret tip,
touch it to the inside wall of the flask, wash it into the bulk solution by careful tilting,
and swirl the solution. The end point is the first appearance of faint pink color that
persists for 15 s. (The color will slowly fade as CO2 from the air dissolves in the
solution.)
), the standard deviation (s), and the percent relative
5. Calculate the average molarity (x
standard deviation (= 100 s/x ). If you were careful, the relative standard deviation
should be < 0.2%.
Standardizing HCl
1. Use the table inside the cover of the textbook to calculate the volume of ~37 wt%
HCl that should be added to 1 L of distilled water to produce 0.1 M HCl and prepare
this solution.
2. Dry primary standard grade sodium carbonate for 1 h at 105C and cool it in a
desiccator.
35
6. Preparing Standard Acid and Base Quantitative Chemical Analysis
3. Weigh four samples, each containing enough Na2CO3 to react with ~25 mL of 0.1 M
HCl and place each in a 125-mL flask. When you are ready to titrate each one,
dissolve it in ~25 mL of distilled water. Add 3 drops of bromocresol green indicator
and titrate one rapidly to a green color to find the approximate end point.
4. Carefully titrate each sample until it turns from blue into green. Then boil the
solution to expel CO2. The color should return to blue. Carefully add HCl from the
buret until the solution turns green again and report the volume of acid at this point.
5. Perform one blank titration of 50 mL of 0.05 M NaCl containing 3 drops of indicator.
Subtract the volume of HCl needed for the blank from that required to titrate
Na2CO3.
6. Calculate the mean HCl molarity, standard deviation, and percent relative standard
deviation.
36
7. Using a pH Electrode for an Acid-Base Titration Quantitative Chemical Analysis
Reagents
Procedure
1. Your instructor will recommend a mass of unknown (58 mmol) for you to weigh
37
7. Using a pH Electrode for an Acid-Base Titration Quantitative Chemical Analysis
accurately and dissolve in distilled water in a 250-mL volumetric flask. Dilute to the
mark and mix well.
2. Following instructions for your particular pH meter, calibrate a meter and glass
electrode, using buffers with pH values near 7 and 4. Rinse the electrode well with
distilled water and blot it dry with a tissue before immersing in any new solution.
3. The first titration is intended to be rough, so that you will know the approximate end
point in the next titration. For the rough titration, pipet 25.0 mL of unknown into a
125-mL flask. If you are titrating an unknown acid, add 3 drops of phenolphthalein
indicator and titrate with standard 0.1 M NaOH to the pink end point, using a 50-mL
buret. If you are titrating an unknown base, add 3 drops of bromocresol green
indicator and titrate with standard 0.1 M HCl to the green end point. Add 0.5 mL of
titrant at a time so that you can estimate the equivalence volume to within 0.5 mL.
Near the end point, the indicator temporarily changes color as titrant is added. If you
recognize this, you can slow down the rate of addition and estimate the end point to
within a few drops.
4. Now comes the careful titration. Pipet 100.0 mL of unknown solution into a 250-mL
beaker containing a magnetic stirring bar. Position the electrode in the liquid so that
the stirring bar will not strike the electrode. If a combination electrode is used, the
small hole near the bottom on the side must be immersed in the solution. This hole is
the salt bridge to the reference electrode. Allow the electrode to equilibrate for 1 min
with stirring and record the pH.
5. Add 1 drop of indicator and begin the titration. The equivalence volume will be four
times greater than it was in step 3. Add ~1.5-mL aliquots of titrant and record the
exact volume, the pH, and the color 30 s after each addition. When you are within 2
mL of the equivalence point, add titrant in 2-drop increments. When you are within 1
mL, add titrant in 1-drop increments. Continue with 1-drop increments until you are
0.5 mL past the equivalence point. The equivalence point has the most rapid change
in pH. Add five more 1.5-mL aliquots of titrant and record the pH after each.
38
7. Using a pH Electrode for an Acid-Base Titration Quantitative Chemical Analysis
Figure 1. Locating the maximum position of the first derivative of a titration curve.
Data Analysis
1. Construct a graph of pH versus titrant volume. Mark on your graph where the
indicator color change(s) was observed.
2. Following the example in Figures 10-5 and 10-6 of the textbook, compute the first
derivative (the slope, pH/V) for each data point within 1 mL of the equivalence
volume. From your graph, estimate the equivalence volume as accurately as you can,
as shown in Figure 1.
3. Following the example in Figure 10-6, compute the second derivative (the slope of
the slope, (slope)/V). Prepare a graph like Figure 10-7 in the textbook and locate
the equivalence volume as accurately as you can.
4. Go back to your graph from step 1 and mark where the indicator color changes were
observed. Compare the indicator end point to the end point estimated from the first
and second derivatives.
5. From the equivalence volume and the mass of unknown, calculate the molecular mass
of the unknown.
39
8. Analysis of a Mixture of Carbonate and Bicarbonate Quantitative Chemical Analysis
HCO3- + H+ H2CO3
Green Profile
See Section 0 CO2-
3 + 2H H2CO3
+
A separate aliquot of unknown is treated with excess standard NaOH to convert HCO3- to
CO2-
3:
HCO3- + OH- CO2-
3 + H2O
Ba2+ + CO2-
3 BaCO3(s)
The excess NaOH is immediately titrated with standard HCl to determine how much
HCO3- was present. From the total alkalinity and bicarbonate concentration, you can
calculate the original carbonate concentration.
Reagents
40
8. Analysis of a Mixture of Carbonate and Bicarbonate Quantitative Chemical Analysis
Procedure
1. Accurately weigh 2.02.5 g of unknown into a 250-mL volumetric flask by weighing the
sample in a capped weighing bottle, delivering some to a funnel in the volumetric flask, and
reweighing the bottle. Continue this process until the desired mass of reagent has been
transferred to the funnel. Rinse the funnel repeatedly with small portions of CO2-free water
to dissolve the sample. Remove the funnel, dilute to the mark, and mix well.
2. Total alkalinity: Pipet a 25.00-mL aliquot of unknown solution into a 250-mL flask and
titrate with standard 0.1 M HCl, using bromocresol green indicator as in Experiment 6 for
standardizing HCl. Repeat this procedure with two more 25.00-mL aliquots.
3. Bicarbonate content: Pipet 25.00 mL of unknown and 50.00 mL of standard 0.1 M NaOH
into a 250-mL flask. Swirl and add 10 mL of 10 wt% BaCl2, using a graduated cylinder.
Swirl again to precipitate BaCO3, add 2 drops of phenolphthalein indicator, and immediately
titrate with standard 0.1 M HCl. Repeat this procedure with two more 25.00-mL samples of
unknown.
4. From the results of step 2, calculate the total alkalinity and its standard deviation. From the
results of step 3, calculate the bicarbonate concentration and its standard deviation. Using
the standard deviations as estimates of uncertainty, calculate the concentration (and
uncertainty) of carbonate in the sample. Express the composition of the solid unknown in a
form such as 63.4 (0.5) wt% K2CO3 and 36.6 (0.2) wt% NaHCO3.
41
9. Analysis of an Acid-Base Titration Curve: The Gran Plot Quantitative Chemical Analysis
Green Profile Using a Gran Plot to Find the End Point of a Titration
See Section 0
A problem with using derivatives to find the end point of a titration is that titration data are least
accurate right near the end point because buffering is minimal and electrode response is sluggish.
A Gran plot uses data from before the end point (typically from 0.8 Ve or 0.9 Ve up to Ve) to
locate the end point.
Consider the titration of a weak acid, HA:
[H+]H+[A-]A-
HA H+ + A- Ka = [HA] HA (1)
Substitution of these values of [A-] and [HA] into the equilibrium constant gives
[H+]H+VbFbA-
Ka = (V F V F )
a a b b HA
42
9. Analysis of an Acid-Base Titration Curve: The Gran Plot Quantitative Chemical Analysis
HA VaFa VbFb
Vb[H+]H+ = - Ka Fb (2)
A
123
10-pH
The term on the left is Vb . 10-pH, because [H+]H+ = 10-pH. The term in parentheses on the
right is
VaFa VbFb VaFa
Fb = Fb Vb = Ve Vb
A graph of Vb . 10-pH versus Vb is called a Gran plot. If HA/A- is constant, the graph is
a straight line with a slope of KaHA/A- and an x-intercept of Ve. Figure 1 shows a Gran plot
for the titration in Figure 10-5 of the textbook. Any units can be used for Vb, but the same units
should be used on both axes. In Figure 1, Vb is expressed in microliters on both axes.
43
9. Analysis of an Acid-Base Titration Curve: The Gran Plot Quantitative Chemical Analysis
The beauty of a Gran plot is that it enables us to use data taken before the end point to
find the end point. The slope of the Gran plot enables us to find Ka. Although we derived the
Gran function for a monoprotic acid, the same plot (Vb . 10-pH versus Vb) applies to polyprotic
acids (such as H6A in Figure 10-5 of the textbook).
The Gran function, Vb . 10-pH, does not actually go to 0, because 10-pH is never 0. The
curve must be extrapolated to find Ve. The reason the function does not reach 0 is that we have
used the approximation that every mole of OH- generates 1 mol of A-, which is not true as Vb
approaches Ve. Only the linear portion of the Gran plot is used.
Another source of curvature in the Gran plot is changing ionic strength, which causes
HA/A- to vary. In Figure 10-5 of the textbook, this variation was avoided by maintaining
nearly constant ionic strength with NaNO3. Even without added salt, the last 1020% of data
before Ve gives a fairly straight line because the quotient HA/A- does not change very much.
The Gran plot in the acidic region gives accurate results even if there is CO2 dissolved in the
strong base titrant. The Gran plot in the basic region can be used to measure CO2 in the strong
base.
For completeness, we note that if weak base, B, is titrated with a strong acid, the Gran
function is
1 B
Va . 10+pH = K . (Ve Va) (4)
a BH+
where Va is the volume of strong acid and Ka is the acid dissociation constant of BH+. A graph
of Va . 10+pH versus Va should be a straight line with a slope of B / (BH+Ka) and an
x-intercept of Ve.
1. Dry about 1.5 g of potassium hydrogen phthalate at 105C for 1 h and cool it in a desiccator
for 20 min. Accurately weigh out ~1.5 g and dissolve it in water in a 250-mL volumetric
flask. Dilute to the mark and mix well.
2. Following the instructions for your particular pH meter, calibrate a meter and glass electrode
using buffers with pH values near 7 and 4. Rinse the electrode well with distilled water and
blot it dry with a tissue before immersing in a solution.
44
9. Analysis of an Acid-Base Titration Curve: The Gran Plot Quantitative Chemical Analysis
3. Pipet 100.0 mL of phthalate solution into a 250-mL beaker containing a magnetic stirring
bar. Position the electrode in the liquid so that the stirring bar will not strike the electrode.
The small hole near the bottom on the side of the combination pH electrode must be
immersed in the solution. This hole is the reference electrode salt bridge. Allow the
electrode to equilibrate for 1 min (with stirring) and record the pH.
4. Add 1 drop of phenolphthalein indicator (recipe in Experiment 7) and titrate the solution with
standard ~0.1 M NaOH. Until you are within 4 mL of the theoretical equivalence point, add
base in ~1.5-mL aliquots, recording the volume and pH 30 s after each addition. Thereafter,
use 0.4-mL aliquots until you are within 1 mL of the equivalence point. After that, add base
1 drop at a time until you have passed the pink end point by a few tenths of a milliliter.
(Record the volume at which the pink color is observed.) Then add five more 1-mL aliquots.
5. Construct a graph of pH versus Vb (volume of added base). Locate the equivalence volume
(Ve) as the point of maximum slope or zero second derivative, as described in Section 10-5.
Compare this with the theoretical and phenolphthalein end points.
1. Construct a Gran plot (a graph of Vb10-pH versus Vb) by using the data collected between
0.9Ve and Ve. Draw a line through the linear portion of this curve and extrapolate it to the
abscissa to find Ve. Use this value of Ve in the calculations below. Compare this value with
those found with phenolphthalein and estimated from the graph of pH versus Vb.
2. Compute the slope of the Gran plot and use Equation 3 to find Ka for potassium hydrogen
phthalate as follows: The slope of the Gran plot is KaHA/A- = KaHP-/P2-. In this
equation, HP- is monohydrogen phthalate (the weak acid) and P2- is phthalate anion (the
weak base). Because the ionic strength changes slightly as the titration proceeds, so also do
the activity coefficients. Calculate the ionic strength at 0.95Ve, and use this average ionic
strength to find the activity coefficients.
Find HP- and P2- at 0.95 Ve in the titration of 100.0 mL of 0.020 0 M potassium hydrogen
phthalate with 0.100 M NaOH.
45
9. Analysis of an Acid-Base Titration Curve: The Gran Plot Quantitative Chemical Analysis
Solution The equivalence point is 20.0 mL, so 0.95Ve, = 19.0 mL. The concentrations of H+
and OH- are negligible compared with those of K+, Na+, HP-, and P2-, whose concentrations are
100 mL
[K+] = 119 mL (0.020 0 M) = 0.016 8 M
Dilution Initial
factor concentration
19 mL
[Na+] = 119 mL (0.100 M) = 0.016 0 M
100 mL
[HP-] = (0.050) 119 mL (0.020 0 M) = 0.000 84 M
Fraction Dilution Initial
remaining factor concentration
100 mL
[P2-] = (0.95) 119 mL (0.020 0 M) = 0.0160 M
= 2 cizi2
1
1
= 2 [ (0.016 8) . 12 + (0.016 0) . 12 + (0.000 84) . 12 + (0.016 0) . 22 ] = 0.048 8 M
To estimate P2- and HP- at = 0.048 8 M, interpolate in Table 7-1. In this table, we find that
the hydrated radius of P2- [phthalate, C6H4(CO -2 )2] is 600 pm. The size of HP- is not listed, but
we will suppose that it is also 600 pm. An ion with charge 2 and a size of 600 pm has = 0.485
at = 0.05 M and = 0.675 at = 0.01 M. Interpolating between these values, we estimate P2-
= 0.49 when = 0.048 8 M. Similarly, we estimate HP- = 0.84 at this same ionic strength.
3. From the measured slope of the Gran plot and the values of HP- and P2-, calculate pKa.
Then choose an experimental point near Ve and one near Ve. Use Equation 1 to find pKa
with each point. (You will have to calculate [P2-], [HP-], P2-, and HP- at each point.)
Compare the average value of pKa from your experiment with pK2 for phthalic acid listed in
the Appendix of the textbook.
46
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
Excel Solver provides tremendous power for curve fitting and solving
equations. Practicing scientists and engineers make frequent use of this
capability, which you will never regret making the effort to learn. Study
Section 10-10 of the textbook before working on this experiment.
We will fit the theoretical titration curve to the potentiometric data
Green Profile
See Section 0 (pH versus volume of titrant) that you obtained in Experiments 7 or 9. The
results of your titration can be plotted in a graph such as Figure 1.
12
Figure 1. pH measured during the titration
10
of acetic acid (HA) with standard NaOH.
8 The objective of Experiment 10 is to fit a
theoretical titration curve to the measured
pH
6
points and extract the concentration of HA
4 and its acid dissociation constant, Ka, from
2
the data.
0 1 2 3 4 5 6 7 8 9 10
Vb (m L)
[H+] [OH-]
A -
Ca
Fraction of titration for CbVb
= CV = (10-13)
weak acid by strong base: a a [H+] [OH-]
1+ Cb
where is the fraction of the way to the end point, Cb is the concentration of standard base, Vb is
the volume of base added at a given point in the titration, Ca is the (unknown) initial
concentration of weak acid, Va is the initial volume of acid being titrated, A- is the fraction of
weak acid in the form A-, [H+] is the concentration of H+ at a point in the titration, and [OH-] is
19. J. Burnett and W. A. Burns, Using a Spreadsheet to Fit Experimental pH Titration Data to a Theoretical
Expression: Estimation of Analyte Concentration and Ka, J. Chem. Ed. 2006, 83, 1190.
47
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
the concentration of OH- at that same point. Equation 10-13 neglects activity coefficients. The
expression for A- is
where Ka is the acid dissociation constant for HA. By finding the curve that best fits the titration
data, we will find the best values of Ca and Ka. You could analyze the titration of a weak base
with standard HCl by modifying Equation 10-14 in the textbook for a strong acid.
Procedure
1. Create a spreadsheet like Figure 2. Type the constants (Cb, Va, etc.) in cells A3:A8. Enter
the known concentration of standard base in cell B3 and the initial volume of HA in cell B4.
Enter 1e-14 for Kw in cell B8. Leave cells B5:B7 blank for the moment
2. Enter experimental volumes of base (Vb,obs) and pH in columns A and B (beginning in cells
A12 and B12 in Figure 2). Prepare a graph of the experimental points, as in Figure 1.
3. Estimate the equivalence volume, Ve. In Figure 1, the steep part of the titration curve is near
Vb = 8 mL. In the spreadsheet, we find the steepest rise in pH between 8.01 and 8.31 mL.
So we can estimate Ve 8.1 mL for this example. (The equivalence point in your titration
will be at some other volume of base.) From the initial volume of acid (Va = 200 mL) and
the concentration of standard base (Cb = 0.4905 M), we can estimate the concentration of
acid:
In Figure 2, we enter the estimated value Ca = 0.019 9 M in cell B5. You will enter the
estimated value of Ca for your titration.
4. For any titration, pH = pKa when Vb = Ve. If Ve 8.1 mL, then Ve 4.05 mL.
Inspecting the data in the spreadsheet, we see that pH 4.85 near Vb 4.05 mL. In Figure 2,
the estimated value of 4.85 for pKa is entered in cell B6. You will enter the estimated pKa
for your titration. The spreadsheet calculates Ka = 10-pKa in cell B7. Eventually, we will use
Excel Solver to find the best values for Ca and pKa to fit the titration data.
48
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
CbVb,calc CaVa
= CaVa Vb,calc = Cb
7. The calculated titration curve is a graph of observed pH versus Vb,calc. We have not yet
optimized the values of Ca and pKa, but we have pretty good estimates that should give a
reasonable fit to the experimental data. To superimpose the calculated titration curve on the
data in Figure 1, click on the graph in your spreadsheet. In Excel 2007, in the Chart Tools
ribbon go to Design and then Select Data. Click Add. Name the new data Calc. The x
values are Vb,calc in column G. The y values are pH in column B. Click OK and the
calculated points appear on the graph. To change the calculated points to a smooth curve,
click on one of the calculated points so they are all highlighted. Select Chart Tools, Format,
Format Selection. For Marker Options, click None to remove the markers. For Line Color,
select Solid Line and give it a color. For Line Style, select a Width of 0.75 points. Click
Close and you should see the smooth calculated curve.
For earlier versions of Excel, go to the Chart menu, select Source Data. Select the Series
tab and click Add. Name the new data Calc. The x values are Vb,calc in column G. The y
values are pH in column B. Click OK and the calculated points appear on the graph. To
change the calculated points to a smooth curve, select the chart symbol of Calc in the legend
of the graph. Double click the chart symbol and the Format Legend Key window appears.
For Line, select Automatic. For Marker, select None. Click OK and you should see the
smooth calculated curve.
49
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
A B C D E F G H I
(wt*residual ) =
2
1 Titration of Acetic Acid with NaOH
+
2 [H ]: C11 = 10^-B11 0.265
-
3 Cb = 0.4905 M [OH ]: D11 = $B$8/C11 = sum(I11:I42)
-
4 Va = 200 mL Alpha(A ): E11 = $B$7/(C11+$B$7)
5 Ca = 0.01990 M Phi: F11 = (E11-(C11-D11)/$B$5)/(1+(C11-D11)/$B$3)
6 pKa = 4.850 Vb,calc: G11 = F11*$B$5*$B$4/$B$3
7 Ka = 1.41E-05 = 10^-B6 Weight: H11 = (B12-B11)/(A12-A11)
2
8 Kw = 1.00E-14 wt*(Vb,obs - Vb,calc) : I11 = H11*(A11-G11)^2
9
2
10 Vb,obs wt*residual =
+ - - 2
11 (mL) pHobs [H ] [OH ] Alpha(A ) Phi Vb,calc Weight wt*(Vb,obs - Vb,calc)
12 0.21 3.48 3.3E-04 3.0E-11 0.041 0.024 0.20 0.80 1.39E-04
13 0.51 3.72 1.9E-04 5.2E-11 0.069 0.059 0.48 0.50 3.89E-04
14 0.81 3.87 1.3E-04 7.4E-11 0.095 0.088 0.71 0.47 4.31E-03
15 1.11 4.01 9.8E-05 1.0E-10 0.126 0.121 0.98 0.47 7.33E-03
16 1.41 4.15 7.1E-05 1.4E-10 0.166 0.163 1.32 0.33 2.66E-03
17 1.71 4.25 5.6E-05 1.8E-10 0.201 0.198 1.61 0.33 3.61E-03
18 2.01 4.35 4.5E-05 2.2E-10 0.240 0.238 1.93 0.23 1.45E-03
19 2.31 4.42 3.8E-05 2.6E-10 0.271 0.269 2.18 0.27 4.34E-03
20 2.61 4.50 3.2E-05 3.2E-10 0.309 0.307 2.49 0.27 3.69E-03
21 2.91 4.58 2.6E-05 3.8E-10 0.349 0.348 2.82 0.30 2.21E-03
22 3.21 4.67 2.1E-05 4.7E-10 0.398 0.397 3.22 0.17 1.44E-05
23 3.51 4.72 1.9E-05 5.2E-10 0.426 0.425 3.45 0.20 8.07E-04
24 3.81 4.78 1.7E-05 6.0E-10 0.460 0.459 3.72 0.23 1.73E-03
25 4.11 4.85 1.4E-05 7.1E-10 0.500 0.499 4.05 0.23 8.06E-04
26 4.41 4.92 1.2E-05 8.3E-10 0.540 0.540 4.38 0.20 2.01E-04
27 4.71 4.98 1.0E-05 9.5E-10 0.574 0.574 4.66 0.23 6.95E-04
28 5.01 5.05 8.9E-06 1.1E-09 0.613 0.613 4.97 0.23 3.48E-04
29 5.31 5.12 7.6E-06 1.3E-09 0.651 0.650 5.28 0.30 3.48E-04
30 5.61 5.21 6.2E-06 1.6E-09 0.696 0.696 5.65 0.27 3.44E-04
31 5.91 5.29 5.1E-06 1.9E-09 0.734 0.733 5.95 0.30 4.96E-04
32 6.21 5.38 4.2E-06 2.4E-09 0.772 0.772 6.26 0.37 1.05E-03
33 6.51 5.49 3.2E-06 3.1E-09 0.814 0.813 6.60 0.40 3.27E-03
34 6.81 5.61 2.5E-06 4.1E-09 0.852 0.852 6.91 0.50 5.18E-03
35 7.11 5.76 1.7E-06 5.8E-09 0.890 0.890 7.22 0.70 9.18E-03
36 7.41 5.97 1.1E-06 9.3E-09 0.929 0.929 7.54 1.03 1.79E-02
37 7.71 6.28 5.2E-07 1.9E-08 0.964 0.964 7.82 3.17 4.06E-02
38 8.01 7.23 5.9E-08 1.7E-07 0.996 0.996 8.08 9.70 4.83E-02
39 8.31 10.14 7.2E-11 1.4E-04 1.000 1.007 8.17 2.37 4.46E-02
40 8.61 10.85 1.4E-11 7.1E-04 1.000 1.037 8.41 1.17 4.44E-02
41 8.91 11.20 6.3E-12 1.6E-03 1.000 1.083 8.79 0.63 9.30E-03
42 9.21 11.39 4.1E-12 2.5E-03 1.000 1.129 9.16 0.50 1.20E-03
43 9.51 11.54 2.9E-12 3.5E-03 1.000 1.183 9.60 0.50 3.68E-03
Figure 2. Initial spreadsheet for fitting Equation 10-13 to experimental points for titration of
HA with standard NaOH.
50
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
A B C D E F G H I
(wt*residual ) =
2
1 Titration of Acetic Acid with NaOH
+
2 [H ]: C11 = 10^-B11 0.240
-
3 Cb = 0.4905 M [OH ]: D11 = $B$8/C11 = sum(I11:I42)
-
4 Va = 200 mL Alpha(A ): E11 = $B$7/(C11+$B$7)
5 Ca = 0.01981 M Phi: F11 = (E11-(C11-D11)/$B$5)/(1+(C11-D11)/$B$3)
6 pKa = 4.840 Vb,calc: G11 = F11*$B$5*$B$4/$B$3
7 Ka = 1.44E-05 = 10^-B6 Weight: H11 = (B12-B11)/(A12-A11)
2
8 Kw = 1.00E-14 wt*(Vb,obs - Vb,calc) : I11 = H11*(A11-G11)^2
9
2
10 Vb,obs wt*residual =
+ - - 2
11 (mL) pHobs [H ] [OH ] Alpha(A ) Phi Vb,calc Weight wt*(Vb,obs - Vb,calc)
12 0.21 3.48 3.3E-04 3.0E-11 0.042 0.025 0.20 0.80 4.57E-05
13 0.51 3.72 1.9E-04 5.2E-11 0.070 0.061 0.49 0.50 1.76E-04
14 0.81 3.87 1.3E-04 7.4E-11 0.097 0.090 0.73 0.47 3.29E-03
15 1.11 4.01 9.8E-05 1.0E-10 0.129 0.124 1.00 0.47 5.64E-03
16 1.41 4.15 7.1E-05 1.4E-10 0.169 0.166 1.34 0.33 1.65E-03
17 1.71 4.25 5.6E-05 1.8E-10 0.204 0.201 1.63 0.33 2.27E-03
18 2.01 4.35 4.5E-05 2.2E-10 0.244 0.242 1.96 0.23 6.99E-04
19 2.31 4.42 3.8E-05 2.6E-10 0.275 0.273 2.21 0.27 2.77E-03
20 2.61 4.50 3.2E-05 3.2E-10 0.314 0.312 2.52 0.27 2.18E-03
21 2.91 4.58 2.6E-05 3.8E-10 0.354 0.353 2.85 0.30 9.96E-04
22 3.21 4.67 2.1E-05 4.7E-10 0.403 0.402 3.25 0.17 2.39E-04
23 3.51 4.72 1.9E-05 5.2E-10 0.431 0.430 3.47 0.20 2.47E-04
24 3.81 4.78 1.7E-05 6.0E-10 0.465 0.464 3.75 0.23 7.91E-04
25 4.11 4.85 1.4E-05 7.1E-10 0.506 0.505 4.08 0.23 2.41E-04
26 4.41 4.92 1.2E-05 8.3E-10 0.546 0.545 4.40 0.20 9.31E-06
27 4.71 4.98 1.0E-05 9.5E-10 0.580 0.579 4.68 0.23 2.34E-04
28 5.01 5.05 8.9E-06 1.1E-09 0.618 0.618 4.99 0.23 8.00E-05
29 5.31 5.12 7.6E-06 1.3E-09 0.656 0.655 5.29 0.30 8.78E-05
30 5.61 5.21 6.2E-06 1.6E-09 0.701 0.700 5.66 0.27 6.23E-04
31 5.91 5.29 5.1E-06 1.9E-09 0.738 0.738 5.96 0.30 7.15E-04
32 6.21 5.38 4.2E-06 2.4E-09 0.776 0.776 6.27 0.37 1.18E-03
33 6.51 5.49 3.2E-06 3.1E-09 0.817 0.817 6.60 0.40 3.08E-03
34 6.81 5.61 2.5E-06 4.1E-09 0.855 0.855 6.90 0.50 4.35E-03
35 7.11 5.76 1.7E-06 5.8E-09 0.893 0.893 7.21 0.70 6.92E-03
36 7.41 5.97 1.1E-06 9.3E-09 0.931 0.931 7.52 1.03 1.24E-02
37 7.71 6.28 5.2E-07 1.9E-08 0.965 0.965 7.79 3.17 2.25E-02
38 8.01 7.23 5.9E-08 1.7E-07 0.996 0.996 8.04 9.70 1.19E-02
39 8.31 10.14 7.2E-11 1.4E-04 1.000 1.007 8.14 2.37 7.14E-02
40 8.61 10.85 1.4E-11 7.1E-04 1.000 1.037 8.38 1.17 6.25E-02
41 8.91 11.20 6.3E-12 1.6E-03 1.000 1.084 8.75 0.63 1.58E-02
42 9.21 11.39 4.1E-12 2.5E-03 1.000 1.130 9.12 0.50 3.67E-03
43 9.51 11.54 2.9E-12 3.5E-03 1.000 1.183 9.56 0.50 1.21E-03
Figure 3. Spreadsheet after executing Solver to optimize the values of Ca and pKa to minimize
the weighted sum of the squares of the residuals in cell I2.
51
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
8. Before finding the best values of Ca and pKa to fit the data, we are going to give each
experimental point a weight in column H. The greater the weight, the more importance we
attach to an experimental point in the least-squares fitting procedure. We could have
weighted all points equally with a weight of 1. An empirical weight that attaches more
significance to points near Ve is the derivative pH / Vb,obs.20 For the first weight in cell
H12, the formula is
This procedure finds a weight for every point except the last one in cell H43, because there is
no data in cells A44 and B44 with which to compute a derivative. For simplicity, assign the
last weight in cell H43 equal to the weight computed in cell H42.
9. In least squares curve fitting, we seek to minimize the sum of squares of the difference
between an observed and a calculated quantity. In your experiment, you measured Vb,obs and
calculated Vb,calc. We want to minimize the sum (Vb,obs Vb,calc)2. To find Ve (and,
therefore Ca) more accurately, we attach higher weights to points near Ve. Therefore, we will
minimize the sum [weight*(Vb,obs Vb,calc)2]. In column I of the spreadsheet compute the
product weight*(Vb,obs Vb,calc)2 for each row. In cell I2, compute the sum of weighted
squares of the residuals:
10. Now we are ready for a least-squares optimization of Ca and pKa to find the theoretical
titration curve that best fits the experimental points. In Excel 2007, in the Data ribbon, select
Solver. (If you dont see Solver in the Analysis section of the ribbon, click the Microsoft
Office button at the top left of the spreadsheet. Click Excel Options and select Add-Ins.
Highlight Solver Add-In, click OK, and Solver is loaded.) In the Data ribbon, click on
Solver. In the Solver window, Set Target Cell $I$2 Equal To Min By Changing Cells
$B$5,$B$6.
20. The weighting function pH / Vb,obs is recommended by Burnett and Burns19 to improve the accuracy of
finding Ve and, hence, Ca. In general, the accuracy of measuring pH is poorest near Ve, so it could be argued
that these points should be given the least weight, not the most weight. However, points near Ve are most
important for finding Ve accurately, so we weight them the highest. The Gran plot in the preceding experiment
is the best way to find Ve without having to rely on less accurate data near Ve.
52
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
Click the Solve button at the upper right. Solver takes a few seconds to vary the quantities
Ca and pKa in cells B5 and B6 to minimize the sum in cell I2. The result is shown in Figure
3. The sum in cell I2 is reduced from 0.428 in Figure 2 to 0.240. The optimum values Ca =
0.01981 M and pKa = 4.840 appear in cells B5 and B6 in Figure 3.
To use Solver in earlier versions of Excel, go to the Tools menu, select Solver, and
follow the same instructions given above. (If you dont see Solver in the Tools menu, select
Add-Ins and click on Solver in the Add-Ins window. Click OK and Solver appears in the
Tools menu.)
11. Superimpose the optimum computed curve on your experimental points to obtain a graph like
Figure 4.
12
Obs
11
Calc
10
Figure 4. Calculated titration
9
curve (smooth line) superimposed
8 on measured points after
optimizing the fit with Solver.
pH
7
6
5
4
3
2
0 1 2 3 4 5 6 7 8 9 10
V b (mL)
53
10. Fitting a Titration Curve with Excel Solver Quantitative Chemical Analysis
Try different starting values of Ca and pKa in cells B5 and B6 to see how well Solver can
optimize two parameters at once. You will find that if the initial values of Ca and pKa are not
close to the correct values, Solver might not be able to find an answer. In this experiment, it
was easy to find values of Ca and pKa that are close to the true values by inspection of the
experimental titration data.
In case you could not find good starting estimates for Ca and pKa, try to optimize one
variable at a time. In the Solver window, Set Target Cell $I$2 Equal To Min By Changing
Cells $B$5. Once Solver has found the best value in cell B5, Set Target Cell $I$2 Equal To
Min By Changing Cells $B$6. With these two individually optimized values in cells B5 and
B6, you can optimize them together by Set Target Cell $I$2 Equal To Min By Changing
Cells $B$5,$B$6.
From this exercise, turn in a graph such as Figure 4 and a spreadsheet such as Figure 3.
Report the optimum values of Ca and pKa that fit your experimental data.
54
11. Kjeldahl Nitrogen Analysis Quantitative Chemical Analysis
Reagents
Digestion
1. Dry your unknown at 105C for 45 min and accurately weigh an amount that will produce
23 mmol of NH3. Place the sample in a dry 500-mL Kjeldahl flask (Figure 10-10 in the
55
11. Kjeldahl Nitrogen Analysis Quantitative Chemical Analysis
textbook), so that as little as possible sticks to the walls. Add 10 g of K2SO4 (to raise the
boiling temperature) and three selenium-coated boiling chips. Pour in 25 mL of 98 wt%
H2SO4, washing down any solid from the walls. (CAUTION: Concentrated H2SO4 eats
people. If you get any on your skin, flood it immediately with water, followed by soap and
water.)
2. In a fume hood, clamp the flask at a 30 angle away from you. Heat gently with a burner
until foaming ceases and the solution becomes homogeneous. Continue boiling gently for an
additional 30 min.
3. Cool the flask for 30 min in the air, and then in an ice bath for 15 min. Slowly, and with
constant stirring, add 50 mL of ice-cold, distilled water. Dissolve any solids that crystallize.
Transfer the liquid to the 500-mL 3-neck distillation flask in Figure 1. Wash the Kjeldahl
flask five times with 10-mL portions of distilled water, and pour the washings into the
distillation flask.
Distillation
1. Set up the apparatus in Figure 1 and tighten the connections well. Pipet 50.00 mL of
standard 0.1 M HCl into the receiving beaker and clamp the funnel in place below the liquid
level.
2. Add 510 drops of phenolphthalein indicator to the three-neck flask in Figure 1 and secure
the stoppers. Pour 60 mL of 50 wt% NaOH into the adding funnel and drip this into the
distillation flask over a period of 1 min until the indicator turns pink. (CAUTION: 50 wt%
NaOH eats people. Flood any spills on your skin with water.) Do not let the last 1 mL
through the stopcock, so that gas cannot escape from the flask. Close the stopcock and heat
the flask gently until two-thirds of the liquid has distilled.
3. Remove the funnel from the receiving beaker before removing the burner from the flask (to
avoid sucking distillate back into the condenser). Rinse the funnel well with distilled water
and catch the rinses in the beaker. Add 6 drops of bromocresol green indicator solution to
the beaker and carefully titrate to the blue end point with standard 0.1 M NaOH. You are
looking for the first appearance of light blue color. (Practice titrations with HCl and NaOH
beforehand to familiarize yourself with the end point.)
4. Calculate the wt% of nitrogen in the unknown.
56
11. Kjeldahl Nitrogen Analysis Quantitative Chemical Analysis
57
12. EDTA Titration of Ca2+ and Mg2+ in Natural Waters Quantitative Chemical Analysis
The most common multivalent metal ions in natural waters are Ca2+ and
Mg2+. In this experiment, we will find the total concentration of metal ions
that can react with EDTA, and we will assume that this equals the
concentration of Ca2+ and Mg2+. In a second experiment, Ca2+ is analyzed
separately after precipitating Mg(OH)2 with strong base.
Green Profile
See Section 0
Reagents
Procedure
1. Dry Na2H2EDTA . 2H2O (FM 372.24) at 80C for 1 h and cool in the desiccator. Accurately
weigh out ~0.6 g and dissolve it with heating in 400 mL of water in a 500-mL volumetric
flask. Cool to room temperature, dilute to the mark, and mix well.
2. Pipet a sample of unknown into a 250-mL flask. A 1.000-mL sample of seawater or a 50.00-
mL sample of tap water is usually reasonable. If you use 1.000 mL of seawater, add 50 mL
of distilled water. To each sample, add 3 mL of pH 10 buffer and 6 drops of Eriochrome
black T indicator. Titrate with EDTA from a 50-mL buret and note when the color changes
58
12. EDTA Titration of Ca2+ and Mg2+ in Natural Waters Quantitative Chemical Analysis
from wine red to blue. Practice finding the end point several times by adding a little tap
water and titrating with more EDTA. Save a solution at the end point to use as a color
comparison for other titrations.
3. Repeat the titration with three samples to find an accurate value of the total Ca2+ + Mg2+
concentration. Perform a blank titration with 50 mL of distilled water and subtract the value
of the blank from each result.
4. For the determination of Ca2+, pipet four samples of unknown into clean flasks (adding 50
mL of distilled water if you use 1.000 mL of seawater). Add 30 drops of 50 wt% NaOH to
each solution and swirl for 2 min to precipitate Mg(OH)2 (which may not be visible). Add
~0.1 g of solid hydroxynaphthol blue to each flask. (This indicator is used because it remains
blue at higher pH than does Eriochrome black T.) Titrate one sample rapidly to find the end
point; practice finding it several times, if necessary.
5. Titrate the other three samples carefully. After reaching the blue end point, allow each
sample to sit for 5 min with occasional swirling so that any Ca(OH)2 precipitate may
redissolve. Then titrate back to the blue end point. (Repeat this procedure if the blue color
turns to red upon standing.) Perform a blank titration with 50 mL of distilled water.
6. Calculate the total concentration of Ca2+ and Mg2+, as well as the individual concentrations
of each ion. Calculate the relative standard deviation of replicate titrations.
59
13. Synthesis and Analysis of Ammonium Decavanadate Exploring Chemical Analysis
The species of aqueous V5+ depend on both pH and concentration (Figure 1).
3 4 4 5 +
VO 4 V2O 7 V4O12 HV10O28 VO2
In strong In strong
base NH +4 , acid
acetic acid,
alcohol
Green Profile
See Section 0
(NH4)6V10O28 . 6H2O
FM 1 173.7
6-
The decavanadate ion (V10 O28 ), which we will isolate in this experiment as the ammonium salt,
consists of 10 VO6 octahedra sharing edges with one another (Figure 2).
21. G. G. Long, R. L. Stanfield, and F. C. Hentz, Jr., J. Chem. Ed. 1979, 56, 195.
60
13. Synthesis and Analysis of Ammonium Decavanadate Exploring Chemical Analysis
Figure 2. Structure of
V10 O6-28 anion, consisting
of VO6 octahedra sharing
edges with one another.
There is a vanadium atom
at the center of each
octahedron.
After preparing this salt, we will determine the vanadium content by a redox titration and
NH +4 by the Kjeldahl method. In the redox titration, V5+ will first be reduced to V4+ with
sulfurous acid and then titrated with standard permanganate.
V10 O6-
28 + H2SO3 VO
2+ + SO
2
Reagents
61
13. Synthesis and Analysis of Ammonium Decavanadate Exploring Chemical Analysis
Synthesis
1. Heat 3.0 g of ammonium metavanadate (NH4VO3) in 100 mL of water with constant stirring
(but not boiling) until most or all of the solid has dissolved. Filter the solution and add 4 mL
of 50 vol% aqueous acetic acid with stirring.
2. Add 150 mL of 95% ethanol with stirring and then cool the solution in a refrigerator or ice
bath.
3. After maintaining a temperature of 0l0C for 15 min, filter the orange product with suction
and wash with two 15-mL portions of ice-cold 95% ethanol.
4. Dry the product in the air (protected from dust) for 2 days. Typical yield is 2.02.5 g.
22. R. M. Fowler and H. A. Bright, J. Res. National Bureau of Standards 1935, 15, 493.
62
13. Synthesis and Analysis of Ammonium Decavanadate Exploring Chemical Analysis
Vanadium Analysis
1. Accurately weigh two 0.3-g samples of ammonium decavanadate into 250-mL flasks and
dissolve each in 40 mL of 1.5 M H2SO4 (with warming, if necessary).
2. In a fume hood, add 50 mL of water and 1 g of NaHSO3 to each and dissolve with swirling.
After 5 min, boil the solution gently for 15 min to remove SO2.
3. Titrate the warm solution with standard 0.02 M KMnO4 from a 50-mL buret. The end point
is taken when the yellow color of VO +2 takes on a dark shade (from excess MnO -4 ) that
persists for 15 s.
4. Calculate the average wt% of vanadium in the ammonium decavanadate and compare your
result to the theoretical value.
1. Set up the apparatus in Figure 1 of Experiment 11 and press the stoppers to make airtight
connections. Pipet 50.00 mL of standard 0.1 M HCl into the receiving beaker and clamp the
funnel in place below the liquid level.
2. Transfer 0.6 g of accurately weighed ammonium decavanadate to the three-neck flask and
add 200 mL of water. Add 510 drops of phenolphthalein indicator and secure the stoppers.
Pour 60 mL of 50 wt% NaOH into the adding funnel and drip this into the distillation flask
over a period of 1 min until the indicator turns pink. (Caution: 50 wt% NaOH eats people.
Flood any spills on your skin with water.) Do not let the last 1 mL through the stopcock, so
that gas cannot escape from the flask. Close the stopcock and heat the flask gently until
two-thirds of the liquid has distilled.
3. Remove the funnel from the receiving beaker before removing the burner from the flask (to
avoid sucking distillate back into the condenser). Rinse the funnel well with distilled water
and catch the rinses in the beaker. Add 6 drops of bromocresol green indicator solution to
the beaker and carefully titrate to the blue end point with standard 0. 1 M NaOH. You are
looking for the first appearance of light blue color. (Several practice titrations with HCl and
NaOH will familiarize you with the end point.)
4. Calculate the weight percent of nitrogen in the ammonium decavanadate.
63
14. Iodimetric Titration of Vitamin C Quantitative Chemical Analysis
Ascorbic acid (vitamin C) is a mild reducing agent that reacts rapidly with
triiodide (See Section 15-7). In this experiment, we will generate a known
excess of I3- by the reaction of iodate with iodide (Reaction 15-18), allow the
reaction with ascorbic acid to proceed, and then back titrate the excess I3-
with thiosulfate (Reaction 15-19 and Color Plate 9).
Green Profile
See Section 0
Reagents
64
14. Iodimetric Titration of Vitamin C Quantitative Chemical Analysis
3. Standardize the thiosulfate solution as follows: Pipet 50.00 mL of KIO3 solution into a flask.
Add 2 g of solid KI and 10 mL of 0.5 M H2SO4. Immediately titrate with thiosulfate until
the solution has lost almost all its color (pale yellow). Then add 2 mL of starch indicator and
complete the titration. Repeat the titration with two additional 50.00-mL volumes of KIO3
solution. From the stoichiometries of Reactions 15-18 and 15-19, compute the average
molarity of thiosulfate and the relative standard deviation.
Analysis of Vitamin C
Commercial vitamin C containing 100 mg per tablet can be used. Perform the following analysis
three times, and find the mean value (and relative standard deviation) for the number of
milligrams of vitamin C per tablet.
1. Dissolve two tablets in 60 mL of 0.3 M H2SO4, using a glass rod to help break the solid.
(Some solid binding material will not dissolve.)
2. Add 2 g of solid KI and 50.00 mL of standard KIO3. Then titrate with standard thiosulfate as
above. Add 2 mL of starch indicator just before the end point.
65
15. Preparation and Iodometric Analysis Quantitative Chemical Analysis
of a High-Temperature Superconductor
In this experiment you will determine the oxygen content of yttrium barium
copper oxide (YBa2Cu3Ox). This material is an example of a
nonstoichiometric solid, in which the value of x is variable, but near 7. Some
of the copper in the formula YBa2Cu3O7 is in the unusual high-oxidation
state, Cu3+. This experiment describes the synthesis of YBa2Cu3Ox, (which
Green Profile
See Section 0 can also be purchased) and then gives two alternative procedures to measure
the Cu3+ content. The iodometric method is based on the reactions in Box
15-3 in the textbook. The more elegant citrate-complexed copper titration26 eliminates many
experimental errors associated with the simpler iodometric method and gives more accurate and
precise results.
Preparation of YBa2Cu3Ox
1. Place in a mortar 0.750 g of Y2O3, 2.622 g of BaCO3, and 1.581 g of CuO (atomic ratio
Y:Ba:Cu = 1:2:3). Grind the mixture well with a pestle for 20 min and transfer the powder to
a porcelain crucible or boat. Heat in the air in a furnace at 920930C for 12 h or longer.
Turn off the furnace and allow the sample to cool slowly in the furnace. This slow cooling
step is critical for achieving an oxygen content in the range x = 6.57 in the formula
YBa2Cu3Ox. The crucible may be removed when the temperature is below 100C.
2. Dislodge the black solid mass gently from the crucible and grind it to a fine powder with a
mortar and pestle. It can now be used for this experiment, but better quality material is
produced if the powder is heated again to 920930C and cooled slowly as in step 1. If the
powder from step 1 is green instead of black, raise the temperature of the furnace by 20C
and repeat step 1. The final product must be black, or it is not the correct compound.
25. D. C. Harris, M. E. Hills, and T. A. Hewston, J. Chem. Ed. 1987, 64, 847. Alternative syntheses of
YBa2Cu3Ox are described by C. D. Cogdell, D. G. Wayment, D. J. Casadonte, Jr., and K. A. Kubat-Martin, J.
Chem. Ed. 1995, 72, 840 and P. I. Djurovich and R. J. Watts, J. Chem. Ed. 1993, 70, 497.
26. E. H. Appelman, L. R. Morss, A. M. Kini, U. Geiser, A. Umezawa, G. W. Crabtree, and K. D. Carlson, Inorg.
Chem. 1987, 26, 3237.
66
15. Preparation and Iodometric Analysis Quantitative Chemical Analysis
of a High-Temperature Superconductor
lodometric Analysis
67
15. Preparation and Iodometric Analysis Quantitative Chemical Analysis
of a High-Temperature Superconductor
their explosion hazard.) Boil gently for 10 min, so that Reaction 1 in Box 15-3 goes to
completion. Cool to room temperature, cap with the two-hole-stopperburet assembly, and
begin N2 flow. Dissolve 1.01.5 g of KI in 10 mL of distilled water and immediately add the
solution to the beaker. Titrate rapidly with magnetic stirring as described in step 3. Repeat
this procedure two more times.
5. Superconductor Experiment B. Place an accurately weighed 150- to 200-mg sample of
powdered YBa2Cu3Ox in the titration beaker and begin N2 flow. Dissolve 1.01.5 g of KI in
10 mL of 1.0 M HClO4 and immediately add the solution to the titration beaker. Stir
magnetically for 1 min, so that the Reactions 2 and 3 of Box 15-3 occur. Add 10 mL of
water and rapidly complete the titration. Repeat this procedure two more times.
Calculations
1. Suppose that mass, mA, is analyzed in Experiment A and the volume, VA, of standard
thiosulfate is required for titration. Let the corresponding quantities in Experiment B be mB
and VB. Let the average oxidation state of Cu in the superconductor be 2 + p. Show that p is
given by
VB / mB VA / mA
p =
VA / mA (1)
7 3
x = 2 + 2 (2 + p) (2)
For example, if the superconductor contains one Cu3+ and two Cu2+, the average oxidation
state of copper is 7/3 and the value of p is 1/3. Setting p = 1/3 in Equation 2 gives x = 7.
Equation 1 does not depend on the metal stoichiometry being exactly Y:Ba:Cu 1:2:3, but
Equation 2 does require this exact stoichiometry.
2. Use the average results of Experiments A and B to calculate the values of p and x in
Equations 1 and 2.
3. Suppose that the uncertainty in mass of superconductor analyzed is 1 in the last decimal
place. Calculate the standard deviations for steps 3, 4, and 5 of the iodometric analysis.
68
15. Preparation and Iodometric Analysis Quantitative Chemical Analysis
of a High-Temperature Superconductor
Using these standard deviations as uncertainties in volume, calculate the uncertainties in the
values of p and x in Equations 1 and 2.
This procedure directly measures Cu3+. The sample is first dissolved in a closed container with
4.4 M HBr, in which Cu3+ oxidizes Br- to Br3-:
11 1
Cu3+ + 2 Br- CuBr2- -
4 + 2 Br3 (3)
The solution is transferred to a vessel containing excess I-, excess citrate, and enough NH3 to
neutralize most of the acid. Cu2+ is complexed by citrate and is not further reduced to CuI(s).
(This eliminates the problem in the iodometric titration of performing a titration in the presence
of colored solid.) Br3- from Reaction 3 oxidizes I- to I -3 :
Procedure
69
15. Preparation and Iodometric Analysis Quantitative Chemical Analysis
of a High-Temperature Superconductor
wt% NH3. The exact amount of NH3 should be enough to neutralize all but 1 mmol of acid
present in the sample. When calculating the acid content, remember that each mole of
YBa2Cu3Ox consumes 2x moles of HBr. (You can estimate that x is close to 7.) Wash the
vial with three 1-mL aliquots of 2 M HBr to complete the quantitative transfer to the beaker.
4. Add 0.1 mL of 1 wt% starch solution and titrate with 0.1 M standard Na2S2O3 under a brisk
flow of N2, using a 250-mL Hamilton syringe to deliver titrant. The end point is marked by a
change from dark blue (I2-starch) to the light blue-green of the Cu2+-citrate complex.
5. Run a blank reaction with CuSO4 in place of superconductor. The moles of Cu in the blank
should be the same as the moles of Cu in the superconductor. In a typical experiment, 30 mg
of YBa2Cu3O6.88 required approximately 350 L of Na2S2O3 and the blank required 10 L
of Na2S2O3 If time permits, run two more blanks. Subtract the average blank from the titrant
in step 4.
6. Repeat the analysis with two more samples of superconductor.
Calculations
-
1. From the thiosulfate required to titrate I 3 released in Reaction 4, find the average moles of
Cu3+ per gram of superconductor (1 mol S2O2- 3+
3 = 1 mol Cu ) and the standard deviation for
your three samples.
2. Defining R as (mol Cu3+ )/(g superconductor), show that z in the formula YBa2Cu3O7z is
1 666.20 R
z = 2 15.999 R (5)
where 666.20 is the formula mass of YBa2Cu3O7 and 15.999 4 is the atomic mass of O.
3. Using your average value of R and using its standard deviation as an estimate of uncertainty,
calculate the average value of z and its uncertainty. Find the average value of x and its
uncertainty in the formula YBa2Cu3Ox. If you are really daring, use Equation C-1 in
Appendix C of the textbook for propagation of uncertainty in Equation 5.
70
16. Potentiometric Halide Titration with Ag+ Quantitative Chemical Analysis
Reagents
Unknowns: Each student receives a vial containing 0.220.44 g of KCl plus 0.501.00 g of KI
(weighed accurately). The object is to determine the quantity of each salt in the mixture.
Buffer (pH 2): (6 mL/student) Titrate 1 M H2SO4 with 1 M NaOH to a pH near 2.0.
Silver nitrate: 1.2 g AgNO3/student.
Procedure
1. Pour your unknown carefully into a 50- or 100-mL beaker. Dissolve the solid in ~20 mL of
water and pour the solution into a 100-mL volumetric flask. Rinse the sample vial and
beaker five times with small portions of H2O and transfer the washings to the flask. Dilute to
the mark and mix well.
2. Dry 1.2 g of AgNO3 (FM 169.87) at 105C for 1 h and cool in a dessicator for 30 min with
minimal exposure to light. Some discoloration is normal (and tolerable in this experiment)
but should be minimized. Accurately weigh 1.2 g and dissolve it in a 100-mL volumetric
flask.
3. Set up the apparatus in Figure 26-11 of the textbook. The silver electrode is simply a 3-cm
length of silver wire soldered to copper wire. (Fancier electrodes can be prepared by housing
the connection in a glass tube sealed with epoxy at the lower end. Only the silver should
protrude from the epoxy.) The copper wire is fitted with a jack that goes to the reference
71
16. Potentiometric Halide Titration with Ag+ Quantitative Chemical Analysis
socket of a pH meter. The reference electrode for this titration is a glass pH electrode
connected to its usual socket on the meter. If a combination pH electrode is employed, the
reference jack of the combination electrode is not used. The silver electrode should be taped
to the inside of the 100-mL beaker so that the Ag/Cu junction remains dry for the entire
titration. The stirring bar should not hit either electrode.
4. Pipet 25.00 mL of unknown into the beaker, add 3 mL of pH 2 buffer, and begin magnetic
stirring. Record the initial level of AgNO3 in a 50-mL buret and add ~1 mL of titrant to the
beaker. Turn the pH meter to the millivolt scale and record the volume and voltage. It is
convenient (but is not essential) to set the initial reading to +800 mV by adjusting the meter.
5. Titrate the solution with ~1-mL aliquots until 50 mL of titrant have been added or until you
can see two abrupt voltage changes. You need not allow more than 1530 s for each point.
Record the volume and voltage at each point. Make a graph of millivolts versus milliliters to
find the approximate positions (1 mL) of the two end points.
6. Turn the pH meter to standby, remove the beaker, rinse the electrodes well with distilled
water, and blot them dry with a tissue. (Silver halide adhering to the glass electrode can be
removed by soaking in concentrated sodium thiosulfate solution. This thorough cleaning is
not necessary between steps 6 and 7 in this experiment. The silver halides in the titration
beaker can be saved and converted back to pure AgNO3.28) Clean the beaker and set up the
titration apparatus again. The beaker need not be dry.
7. Perform an accurate titration using 1-drop aliquots near the end points (and 1-mL aliquots
elsewhere). You need not allow more than 30 s per point for equilibration.
8. Prepare a graph of millivolts versus milliliters and locate the end points as in Figure 26-10 of
the textbook. The I- end point is taken as the intersection of the two dashed lines in the inset
of Figure 26-10. The Cl- end point is the inflection point (the steepest point) at the second
break. Calculate milligrams of KI and milligrams of KCl in your solid unknown.
A variation of the preceding procedure could make a class project in environmental analysis.
For example, you could study changes in streams as a function of the season or recent rainfall.
72
16. Potentiometric Halide Titration with Ag+ Quantitative Chemical Analysis
You could study stratification (layering) of water in lakes. The measurement responds to all ions
that precipitate with Ag+, of which Cl- is, by far, the dominant ion in natural waters.
You can use the electrodes in Figure 26-11 of the textbook, or you can construct the
rugged combination electrode shown in Figure 1.29 The indicator electrode in Figure 1 is a bare
silver wire in contact with analyte solution. The inner (reference) chamber of the combination
electrode contains a copper wire dipped into CuSO4 solution. The inner electrode maintains a
constant potential because the concentration of Cu2+ in the solution is constant. The solution
makes electrical contact at the septum, where a piece of thread leaves enough space for solution
to slowly drain from the electrode into the external sample solution.
Procedure
1. Collect water from streams or lakes or from the ocean. To minimize bacterial growth, plastic
jugs should be filled to the top and tightly sealed. Refrigeration is recommended.
29. G. Lisensky and K. Reynolds, J. Chem. Ed. 1991, 68, 334; R. Ramette, Chemical Equilibrium (Reading, MA:
Addison-Wesley, 1981), p. 649.
73
16. Potentiometric Halide Titration with Ag+ Quantitative Chemical Analysis
74
17. Electrogravimetric Analysis of Copper Quantitative Chemical Analysis
Procedure
1. Handle the Pt gauze cathode with a tissue, touching only the thick stem, not the wire gauze.
Immerse the electrode in hot 8 M HNO3 to remove previous deposits, rinse with water and
alcohol, dry at 105C for 5 min, cool for 5 min, and weigh accurately. If the electrode
contains any grease, it can be heated to red heat over a burner after the treatment above.32
2. The sample should contain 0.20.3 g of Cu in 100 mL. Add 3 mL of 98 wt% H2SO4 and
2 mL of freshly boiled 8 M HNO3. Position the cathode so that the top 5 mm are above the
liquid level after magnetic stirring is begun. Adjust the current to 2 A, which should require
34 V. When the blue color of Cu(II) has disappeared, add some distilled water so that new
Pt surface is exposed to the solution. If no further deposition of Cu occurs on the fresh
surface in 15 min at a current of 0.5 A, the electrolysis is complete. If deposition is
observed, continue electrolysis and test the reaction for completeness again.
75
17. Electrogravimetric Analysis of Copper Quantitative Chemical Analysis
3. Without turning off the power, lower the beaker while washing the electrode with a squirt
bottle. Then the current can be turned off. (If current is disconnected before removing the
cathode from the liquid and rinsing off the acid, some Cu could redissolve.) Wash the
cathode gently with water and alcohol, dry at 105C for 3 min, cool in a desiccator for 5 min,
and weigh.
4. Report the mass of Cu in the unknown.
76
18. Polarographic Measurement of an Equilibrium Constant Quantitative Chemical Analysis
In this experiment, you will find the overall formation constant (p) and
stoichiometry for the reaction of oxalate with Pb2+:
2- 2-2 p [Pb(C 2 O 4 ) 2p 2 p ]
Pb2+ + pC2 O4 Pb(C2O4 ) p p =
[Pb 2 + ][C 2 O 24 ] p
Green Profile
See Section 0
where p is a stoichiometry coefficient. We will do this by measuring the
polarographic half-wave potential for solutions containing Pb2+ and various amounts of oxalate.
Polarography is described in Section 16-5 of the textbook. The change of half-wave potential,
E1/2 [= E1/2(observed) E1/2(for Pb2+ without oxalate)] is expected to obey the equation
RT pRT 2-
E1/2 = nF lnp nF ln[C2 O4 ] (1)
where R is the gas constant, F is the Faraday constant, and T is temperature in kelvins. You
should measure the lab temperature at the time of the experiment or use a thermostatically
controlled cell.
An electrode reaction is considered to be reversible when it is fast enough to maintain
equilibrium at the electrode surface. The shape of a reversible polarographic wave is given by
E = E1/2 nF lnI I
RT I
(2)
d
where I is current and Id is diffusion current (the current at the plateau of the wave).
Procedure
1. Pipet 1.00 mL of 0.020 M Pb(NO3)2 into each of five 50-mL volumetric flasks labeled AE
and add 1 drop of 1 wt% Triton X-100 to each. Then add the following solutions and dilute
to the mark with water. The KNO3 may be delivered carefully with a graduated cylinder.
The oxalate should be pipetted.
77
18. Polarographic Measurement of an Equilibrium Constant Quantitative Chemical Analysis
78
19. Coulometric Titration of Cyclohexene with Bromine Quantitative Chemical Analysis
Br2 + (2)
Br
Cyclohexene trans-1,2-Dibromocyclohexane
The initial solution contains an unknown quantity of cyclohexene and a large amount of Br-.
When Reaction 1 has generated just enough Br2 to react with all the cyclohexene, the moles of
electrons liberated in Reaction 1 are equal to twice the moles of Br2 and therefore twice the
moles of cyclohexene.
The reaction is carried out at a constant current with the apparatus in Figure 1. Br2
generated at the Pt anode at the left immediately reacts with cyclohexene. When cyclohexene is
consumed, the concentration of Br2 suddenly rises, signaling the end of the reaction.
The equation relating moles of electrons to the electric current and the time is
I.t
Moles of e- =
Relation between electrons,
F (3)
current, and time:
where I is the current in amperes (= coulombs/s = C/s), t is the time in seconds, and F is the
Faraday constant (96 485 C/mol).
The rise in Br2 concentration is detected by measuring the current between the two
detector electrodes at the right in Figure 1. A voltage of 0.25 V applied between these two
electrodes is not enough to electrolyze any solute, so only a tiny current of <1 A flows through
the microammeter. At the equivalence point, cyclohexene is consumed, [Br2] suddenly
increases, and detector current flows by virtue of the reactions:
79
19. Coulometric Titration of Cyclohexene with Bromine Quantitative Chemical Analysis
In our procedure, enough Br2 is first generated in the absence of cyclohexene to give a
detector current of 20.0 A. When cyclohexene is added, the current decreases to a tiny value
because Br2 is consumed. Br2 is then generated by the coulometric circuit, and the end point is
taken when the detector again reaches 20.0 A. Because the reaction is begun with Br2 present,
impurities that can react with Br2 before analyte is added are eliminated.
The electrolysis current (not to be confused with the detector current) for the
Br2-generating electrodes can be controlled by a hand-operated switch. As the detector current
approaches 20.0 A, you close the switch for shorter and shorter intervals. This practice is
analogous to adding titrant dropwise from a buret near the end of a titration. The switch in the
coulometer circuit serves as a stopcock for addition of Br2 to the reaction.
80
19. Coulometric Titration of Cyclohexene with Bromine Quantitative Chemical Analysis
In Reactions 1 and 2, each mole of cyclohexene requires 1 mol of Br2, which requires 2 mol of
electrons. For 0.014 88 mmol of cyclohexene to react, 0.029 76 mmol of electrons must flow.
From Equation 3,
For this experiment, you can use a commercial coulometer or the circuits in Figure 2.35
Start timing with a stopwatch when the generator switch is closed.
Figure 2. Circuits for coulometric titrations. (a) Generator circuit. (b) Detector circuit.
35. A constant-current circuit for coulometer generator electrodes is given by J. Swim, E. Earps, L. M. Reed, and
D. Paul, J. Chem. Ed. 1996, 73, 679. An operational amplifier circuit for the detector and a circuit for
controlled-potential coulometry are given by E. Grimsrud and J. Amend, J. Chem. Ed. 1979, 56, 131.
81
19. Coulometric Titration of Cyclohexene with Bromine Quantitative Chemical Analysis
Procedure
1. The electrolyte is a 60:26:14 (vol/vol/vol) mixture of acetic acid, methanol, and water. The
solution contains 0.15 M KBr and 0.1 g of mercuric acetate per 100 mL. (The latter
catalyzes the reaction between Br2 and cyclohexene.) The electrodes should be covered with
electrolyte. Begin vigorous magnetic stirring (without spattering) and adjust the voltage of
the detector circuit to 0.25 V.
2. Generate Br2 with the generator circuit until the detector current is 20.0 A. The generator
current should be ~510 mA.
3. Pipet 25 mL of unknown (containing 15 mg of cyclohexene in methanol) into the flask and
set the clock or coulometer to 0. The detector current should drop to near 0 because the
cyclohexene consumes the Br2.
4. Turn the generator circuit on and begin timing. While the reaction is in progress, measure
the voltage (E) across the precision resistor (R = 100.0 0.1 ) to find the exact current (I)
flowing through the cell (I = E/R). Continue the electrolysis until the detector current rises
to 20.0 A. Then stop the coulometer and record the time.
5. Repeat the procedure two more times and find the average molarity (and relative standard
deviation) of cyclohexene.
6. When you are finished, be sure all switches are off. Soak the generator electrodes in 8 M
HNO3 to dissolve Hg that is deposited during the electrolysis.
82
20. Spectrophotometric Determination of Iron in Vitamin Tablets Quantitative Chemical Analysis
Hydroquinone Quinone
`` FM 110.11
N N
3 + Fe2+ Fe2+
N N
3
o-Phenanthroline max = 510 nm
FM 180.21 Red complex
Reagents
Hydroquinone: (20 mL/student) Freshly prepared solution containing 10 g/L in distilled water.
Store in an amber bottle.
Trisodium citrate: (20 mL/student) 25 g/L Na2citrate . 2H2O (FM 294.10) in distilled water.
o-Phenanthroline: (25 mL/student) Dissolve 2.5 g in 100 mL of ethanol and add 900 mL of
distilled water. Store in an amber bottle.
6 M HCl: (25 mL/student) Dilute 124 mL of 37 wt% HCl up to 250 mL with distilled water.
Standard Fe (40 g Fe/mL): (35 mL/student) Dissolve 0.281 g of reagent-grade
Fe(NH4)2(SO4)2 . 6H2O (FM 392.14) in distilled water in a 1-L volumetric flask containing
1 mL of 98 wt% H2SO4.
Procedure
1. Place one tablet of the iron-containing vitamin in a 125-mL flask or 100-mL beaker and boil
gently (in a fume hood) with 25 mL of 6 M HCl for 15 min. Filter the solution directly into a
83
20. Spectrophotometric Determination of Iron in Vitamin Tablets Quantitative Chemical Analysis
100-mL volumetric flask. Wash the beaker and filter several times with small portions of
water to complete a quantitative transfer. Allow the solution to cool, dilute to the mark and
mix well. Dilute 5.00 mL of this solution to 100.0 mL in a fresh volumetric flask. If the
label indicates that the tablet contains <15 mg of Fe, use 10.00 mL instead of 5.00 mL.
2. Pipet 10.00 mL of standard Fe solution into a beaker and measure the pH (with pH paper or a
glass electrode). Add sodium citrate solution 1 drop at a time until a pH of ~3.5 is reached.
Count the drops needed. (It will require about 30 drops.)
3. Pipet a fresh 10.00-mL aliquot of Fe standard into a 100-mL volumetric flask and add the
same number of drops of citrate solution as required in step 2. Add 2.00 mL of
hydroquinone solution and 3.00 mL of o-phenanthroline solution, dilute to the mark with
water, and mix well.
4. Prepare three more solutions from 5.00, 2.00, and 1.00 mL of Fe standard and prepare a
blank containing no Fe. Use sodium citrate solution in proportion to the volume of Fe
solution. (If 10 mL of Fe requires 30 drops of citrate solution, 5 mL of Fe requires 15 drops
of citrate solution.)
5. Determine how many drops of citrate solution are needed to bring 10.00 mL of the iron tablet
solution from step 1 to pH 3.5. This will require about 3.5 or 7 mL of citrate, depending on
whether 5 or 10 mL of unknown was diluted in the second part of step 1.
6. Transfer 10.00 mL of solution from step 1 to a 100-mL volumetric flask. Add the required
amount of citrate solution determined in step 5. Then add 2.00 mL of hydroquinone solution
and 3.0 mL of o-phenanthroline solution. Dilute to the mark and mix well.
7. Allow the solutions to stand for at least 10 min. Then measure the absorbance of each
solution at 510 nm in a 1-cm cell. (The color is stable, so all solutions may be prepared and
all the absorbances measured at once.) Use distilled water in the reference cuvet and subtract
the absorbance of the blank from the absorbance of the Fe standards.
8. Make a graph of absorbance versus micrograms of Fe in the standards. Find the slope and
intercept (and standard deviations) by the method of least squares. Calculate the molarity of
+ 2
Fe(o-phenanthroline)3 in each solution and find the average molar absorptivity ( in Beer's
law) from the four absorbances. (Remember that all the iron has been converted to the
phenanthroline complex.)
9. Using the calibration curve, find the number of milligrams of Fe in the tablet. Use Equation
4-27 in the textbook to find the uncertainty in the number of milligrams of Fe.
84
21. Microscale Spectrophotometric Measurement of Iron by Standard Addition Quantitative Chemical Analysis
Procedure
1. Fill a clean porcelain crucible with 6 M HCl in the hood and allow it to stand for 1 h to
remove traces of iron from previous use. Rinse well with distilled water and dry. After
weighing the empty crucible, add 56 g of finely chopped food sample and weigh again to
obtain the mass of food. (Some foods, like frozen peas, should not be chopped because they
will lose their normal liquid content.)
2. This step could require 3 h, during which you can be doing other lab work. Carefully heat
the crucible with a Bunsen burner in a hood (Experiment 3, Figure 1). Use a low, flame to
dry the sample, being careful to avoid spattering. Increase the flame temperature to char the
sample. Keep the crucible lid and tongs nearby. If the sample bursts into flames, use tongs
to place the lid on the crucible to smother the flame. After charring, use the hottest possible
flame to ignite the black solid, converting it to white ash. The bottom of crucible should be
red hot during ignition. Continue ignition until all traces of black disappear.
85
21. Microscale Spectrophotometric Measurement of Iron by Standard Addition Quantitative Chemical Analysis
3. After cooling the crucible to room temperature, add 10.00 mL of 2.0 M HCl by pipet and
swirl gently for 5 min to dissolve the ash. Filter the mixture through a small filter and collect
the filtrate in a vial or small flask. You need to recover >8 mL for the analysis.
4. Weigh 0.71 g of trisodium citrate dehydrate into each of four 10-mL volumetric flasks.
Using a 2-mL volumetric pipet or a 1-mL micropipet, add 2.00 mL of ash solution to each
flask. Add 4 mL of distilled water and swirl to dissolve the citrate. The solution will have a
pH near 3.6. Using a micropipet, add 0.20 mL of hydroquinone solution and 0.30 mL of
phenanthroline solution to each flask.
5. Label the volumetric flasks 0 through 3. Add no Fe standard to flask 0. Using a micropipet,
add 0.250 mL of Fe standard to flask 1. Add 0.500 mL of Fe standard to flask 2 and 0.750
mL to flask 3. The four flasks now contain 0, 1, 2, and 3 g Fe/mL, in addition to Fe from
the food. Dilute each to the mark with distilled water, mix well, and allow 15 min to develop
full color.
6. Prepare a blank by mixing 0.71 g of trisodium citrate dehydrate, 2.00 mL of 2.0 M HCl, 0.20
mL of hydroquinone solution, 0.30 mL of phenanthroline solution and diluting to 10 mL.
The blank does not require a volumetric flask.
7. Measure the absorbance of each solution at 512 nm in a 1-cm cell with distilled water in the
reference cell. Before each measurement, remove all liquid from the cuvet with a Pasteur
pipet. Then use ~1 mL of your next solution (delivered with a clean, dry Pasteur pipet) to
wash the cuvet. Remove and discard the washing. Repeat the washing once more with fresh
solution and discard the washing. Finally, add your new solution to the cuvet for measuring
absorbance.
8. Subtract the absorbance of the blank from each reading and make a graph like that in Figure
5-6 in the textbook to find the Fe content of the unknown solution. Calculate the wt% of Fe
in the food. Use Equation 5-10 in the textbook to estimate the uncertainty in the wt% of Fe
in the food.
86
22. Spectrophotometric Measurement of an Equilibrium Constant Quantitative Chemical Analysis
Green Profile
I2 + N I2 N
See Section 0
Iodine-pyridine
complex
Both I2 and I2.pyridine absorb visible radiation, but pyridine is colorless. Analysis of the
spectral changes associated with variation of pyridine concentration (with a constant total
concentration of iodine) will allow us to evaluate K for the reaction. The experiment is best
performed with a recording spectrophotometer, but single-wavelength measurements can be
used.
Procedure
All operations should be carried out in a fume hood, including pouring solutions into and out of
the spectrophotometer cell. Only a capped cuvette containing the solution whose spectrum is to
be measured should be taken from the hood. Do not spill solvent on your hands or breathe the
vapors. Used solutions should be discarded in a waste container in the hood, not down the drain.
38. For literature values of the equilibrium constant for the reaction between I2 and pyridine, see S. S. Barton and
R. H. Pottier, J. Chem. Soc. Perkin Trans. II 1984, 731.
87
22. Spectrophotometric Measurement of an Equilibrium Constant Quantitative Chemical Analysis
3. Using glass or quartz cells, record a baseline between 350 and 600 nm with solvent in both
the sample and the reference cells. Subtract the absorbance of the baseline from all future
absorbances. If possible, record all spectra, including the baseline, on one sheet of chart
paper. (If a fixed-wavelength instrument is used, first find the positions of the two
absorbance maxima in solution E. Then make all measurements at these two wavelengths.)
4. Record the spectrum of each solution AF or measure the absorbance at each maximum if a
fixed-wavelength instrument is used.
Data Analysis
1. Measure the absorbance at the wavelengths of the two maxima in each spectrum. Be sure to
subtract the absorbance of the blank from each.
2. The analysis of this problem follows that of Reaction 18-10 in the textbook, in which P is
iodine and X is pyridine. As a first approximation, assume that the concentration of free
pyridine equals the total concentration of pyridine in the solution (because [pyridine] >>
[I2]). Prepare a graph of A/[free pyridine] versus A (a Scatchard plot), using the
absorbance at the I2.pyridine maximum.
3. From the slope of the graph, find the equilibrium constant by using Equation 18-16. From
the intercept, find (= PX X).
4. Now refine the values of K and . Use to find PX. Then use the absorbance at the
wavelength of the I2 . pyridine maximum to find the concentration of bound and free pyridine
in each solution. Make a new graph of A /[free pyridine] versus A, using the new values
of [free pyridine]. Find a new value of K and . If justified, perform another cycle of
refinement.
88
22. Spectrophotometric Measurement of an Equilibrium Constant Quantitative Chemical Analysis
5. Using the values of free pyridine concentration from your last refinement and the values of
absorbance at the I2 maximum, prepare another Scatchard plot and see if you get the same
value of K.
6. Explain why an isosbestic point is observed in this experiment.
89
23. Spectrophotometric Analysis of a Mixture Quantitative Chemical Analysis
O CH3
Green Profile H3C N
See Section 0 N
CO2H
O N N
CH3
Caffeine Benzoic acid (pKa = 4.20)
FM 182.18 FM 122.12
All solutions will contain 0.010 M HCl, so the sodium benzoate is protonated to make benzoic
acid. Caffeine has no appreciable basicity, so it is neutral at pH 2.
1.6
All solutions contain 0.010 M HCl
1.4
Figure 1. Ultraviolet
1.2
absorption of benzoic
acid, caffeine, and a
1.0 Benzoic acid 1:50 dilution of
8.74 mg/L
Mountain Dew soft
Absorbance
0.8
drink. All solutions
contain 0.010 M HCl.
Mountain Dew soda
1:50 dilution
0.6 Caffeine
10.88 mg/L
0.4
0.2
0.0
200 220 240 260 280 300
Wavelength nm)
39. V. L. McDevitt, A. Rodriquez and K. R. Williams, J. Chem. Ed. 1998, 75, 625.
90
23. Spectrophotometric Analysis of a Mixture Quantitative Chemical Analysis
We restrict ourselves to non-diet soft drinks because the sugar substitute aspartame in
diet soda has some ultraviolet absorbance that slightly interferes in the present experiment. We
also avoid darkly colored drinks because the colorants have ultraviolet absorbance. Mountain
Dew, Mello Yello, and, probably, other lightly colored drinks are suitable for this experiment.
There is undoubtedly some ultraviolet absorbance from colorants in these beverages that
contributes systematic error to this experiment.
The procedure we describe includes the construction of calibration curves. The
experiment could be shortened by recording just one spectrum of caffeine (20 mg/L) and one of
benzoic acid (10 mg/L) and assuming that Beer's law is obeyed. The experiment could be
expanded to use high-performance liquid chromatography (HPLC) and/or capillary
electrophoresis to obtain independent measurements of caffeine and benzoic acid (and aspartame
in diet drinks).39
Reagents
Stock solutions: An accurately known solution containing ~100 mg benzoic acid/L in water and
another containing ~200 mg caffeine/L should be available.
0.10 M HCl: Dilute 8.2 mL of 37 wt% HCl to 1 L.
Procedure
91
23. Spectrophotometric Analysis of a Mixture Quantitative Chemical Analysis
absorbance for benzoic acid (') and the wavelength for the peak absorbance of caffeine ('').
Measure the absorbance of each standard at both wavelengths and subtract the baseline
absorbance (if your instrument does not do this automatically). Prepare a calibration graph
of absorbance versus concentration (M) for each compound at each of the two wavelengths.
Each graph should go through 0. The least-squares slope of the graph is the molar
absorptivity at that wavelength.
4. Unknowns: Measure the ultraviolet absorption spectrum of the 2:100 and 4:100 dilutions of
the soft drink. With the absorbance at the wavelengths ' and '', use Equation 18-6 in the
textbook to find the concentrations of benzoic acid and caffeine in the original soft drink.
Report results from both dilute solutions.
5. Synthetic unknown: If your instructor chooses, measure the spectrum of a synthetic,
unknown mixture of benzoic acid and caffeine prepared by the instructor. Use Equation 18-6
in the textbook to find the concentration of each component in the synthetic unknown.
92
24. Mn2+ Standardization by EDTA Titration Quantitative Chemical Analysis
Green Profile
See Section 0
Reagents
Procedure
1. Standard 0.005 M EDTA: Dry Na2H2EDTA . 2H2O (FM 372.25) at 80C for 1 h and cool in
a desiccator. Accurately weigh out ~0.93 g and dissolve it with heating in 400 mL of
distilled water in a 500-mL volumetric flask. Cool to room temperature, dilute to the mark,
and mix well.
2. Mn2+ stock solution: Prepare a solution containing ~1.0 mg Mn/mL (~0.018 M) by
dissolving ~0.77 g MnSO4.H2O (FM 169.01) in a clean plastic screw cap bottle with 250 mL
water delivered from a graduated cylinder. Masses and volumes need not be accurate
because you will standardize this solution.
3. Rinse a clean 50-mL pipet several times with small volumes of Mn2+ stock solution and
discard the washings into a chemical waste container. Then pipet 50.00 mL of Mn2+ stock
solution into a 250-mL volumetric flask. Add 0.80 g of solid hydroxylamine hydrochloride
40. Adapted from San Jose State University Laboratory Manual for a curriculum described by S. P. Perone,
J. Pesek, C. Stone, and P. Englert, J. Chem. Ed. 1998, 75, 1444.
93
24. Mn2+ Standardization by EDTA Titration Quantitative Chemical Analysis
to the flask, and swirl to dissolve the solid. Add ~150 mL of water and swirl to mix the
contents. Dilute to the mark with water, place the cap firmly in place, and invert 20 times to
mix the solution. This solution contains ~0.0036 M Mn2+. The reducing agent,
hydroxylamine, maintains manganese in the +2 state.
4. Rinse a 50-mL pipet several times with small volumes of the diluted Mn2+ solution from step
3. Pipet 50 mL of the diluted Mn2+ solution into a 250-mL Erlenmeyer flask Add 10 mL of
pH 9.7 buffer (by graduated cylinder), and add 3-5 drops of calmagite indicator. The pH of
the solution will be near 9.2. Titrate with standard EDTA from a 50-mL buret and note the
end point when the color changes from wine red to blue.
5. Repeat step 4 twice more to obtain a total of three replicate titrations. The Erlenmeyer flask
must be clean, but it need not be dry for each new titration.
6. From the molarity and volume of standard EDTA required for titration, calculate the molarity
and standard deviation of the original ~0.018 M MnSO4 stock solution. Express your answer
with an appropriate number of significant digits.
94
25. Measuring Mn in Steel by Spectrophotometric Standard Addition Quantitative Chemical Analysis
Green Profile
permanganate ion, whose absorbance is measured with a spectrophotometer:
See Section 0
2Mn2+ + 5IO4- + 3H2O 2MnO + 5IO3- + 6H+
Periodate Permanganate Iodate
(colorless) (colorless) (violet) (colorless)
max 525 nm
Steel is an alloy of iron that typically contains ~0.5 wt% Mn plus numerous other
elements. When steel is dissolved in hot nitric acid, the iron is converted to Fe(III).
Spectrophotometric interference in the measurement of MnO4- by Fe(III) is minimized by adding
H3PO4 to form a nearly colorless complex with Fe(III). Interference by most other colored
impurities is eliminated by subtracting the absorbance of a reagent blank from that of the
unknown. Appreciable Cr in the steel will interfere with the present procedure. Carbon from the
steel is eliminated by oxidation with peroxydisulfate (S2O2-
8 ):
C(s) + 2S2O2-
8 + 2H2O CO2(g) + 4SO2-
4 + 4H+
Reagents
3 M Nitric acid: (150 mL/student) Dilute 190 mL of 70 wt% HNO3 to 1 L with water.
0.05 M Nitric acid: (300 mL/student) Dilute 3.2 mL of 70 wt% HNO3 to 1 L with water.
Ammonium hydrogen sulfite: (0.5 mL/student) 45 wt% NH4HSO3 in water.
Potassium periodate (KIO4): 1.5 g/student.
Unknowns: Steel, ~2 g/student. Analyzed samples are available from Thorn Smith.2
41. Adapted from San Jose State University Laboratory Manual for a curriculum described by S. P. Perone, J.
Pesek, C. Stone, and P. Englert, J. Chem. Ed. 1998, 75, 1444.
95
25. Measuring Mn in Steel by Spectrophotometric Standard Addition Quantitative Chemical Analysis
Procedure
1. Steel can be used as received or, if it appears to be coated with oil or grease, it should be
rinsed with acetone and dried at 110C for 5 min, and cooled in a desiccator.
2. Weigh duplicate samples of steel to the nearest 0.1 mg into 250 mL beakers. The mass of
steel should be chosen to contain ~2-4 mg of Mn. For example, if the steel contains 0.5 wt%
Mn, a 0.6-g sample will contain 3 mg of Mn. Your instructor should give you guidance on
how much steel to use.
3. Dissolve each steel sample separately in 50 mL of 3 M HNO3 by gently boiling in the hood,
while covered with a watchglass. If undissolved particles remain, stop boiling after 1 h.
Replace the HNO3 as it evaporates.
4. Standard Mn2+ (~0.1 mg Mn/mL): While the steel is dissolving, pipet 10.00 mL of standard
Mn2+ (~1 mg Mn/mL) from Experiment 24 into a 100-mL volumetric flask, dilute to the
mark with water, and mix well. You will use this solution in Experiments 25 and 26. Keep
it stoppered, and wrap the stopper with Parafilm or tape to minimize evaporation.
5. Cool the beakers from step 3 for 5 min. Then carefully add ~1.0 g of (NH4)2S2O8 or
K2S2O8 and boil for 15 min to oxidize carbon to CO2.
6. If traces of pink color (MnO4- ) or brown precipitate (MnO2) are observed, add 6 drops of 45
wt% NH4HSO3 and boil for 5 min to reduce all manganese to Mn(II):
2MnO4- + 5HSO3-
+ H+ 2Mn2+ + 5SO2-
4 + 3H2O
MnO2(s) + HSO3- + H+ Mn2+ + SO2-
4 + H2O
(The purpose of removing colored species at this time is that the solution from step 6 is
eventually going to serve as a colorimetric reagent blank.)
7. After cooling the solutions to near room temperature, filter each solution quantitatively
through #41 filter paper into a 250-mL volumetric flask. (If gelatinous precipitate is present,
use #42 filter paper.) To complete a quantitative transfer, wash the beaker many times
with small volumes of hot 0.05 M HNO3 and pass the washings through the filter to wash
liquid from the precipitate into the volumetric flask. Finally, allow the volumetric flasks to
cool to room temperature, dilute to the mark with water, and mix well.
8. Transfer ~100 mL of solution from each 250-mL volumetric flask to clean, dry Erlenmeyer
flasks and stopper the flasks tightly. Label these solutions A and B and save them for atomic
96
25. Measuring Mn in Steel by Spectrophotometric Standard Addition Quantitative Chemical Analysis
absorption analysis in Experiment 26. To help prevent evaporation, it is a good idea to seal
around the stoppers with a few layers of Parafilm or tape.
9. Carry out the following spectrophotometric analysis with one of the unknown steel solutions
prepared in step 7:
a. Pipet 25.00 mL of liquid from the 250-mL volumetric flask in step 7 into each of three
clean, dry 100-mL beakers designated blank, unknown, and standard addition.
Add 5 mL of 85 wt% H3PO4 (from a graduated cylinder) into each beaker. Then add
standard Mn2+ (0.1 mg/mL from step 4, delivered by pipet) and solid KIO4 as follows:
Volume of Mass of
Beaker Mn2+ (mL) KIO4 (g)
Blank 0 0
Unknown 0 0.4
Standard addition 5.00 0.4
b. Boil the unknown and standard addition beakers gently for 5 min to oxidize Mn2+ to
MnO4- . Continue boiling, if necessary, until the KIO4 dissolves.
c. Quantitatively transfer the contents of each of the three beakers into 50-mL volumetric
flasks. Wash each beaker many times with small portions of water and transfer the water
to the corresponding volumetric flask. Dilute each flask to the mark with water and mix
well.
d. Fill one 1.000-cm-pathlength cuvet with unknown solution and another cuvet with blank
solution. It is always a good idea to rinse the cuvet a few times with small quantities of
the solution to be measured and discard the rinses.
e. Measure the absorbance of the unknown at 525 nm with blank solution in the reference
cuvet. For best results, measure the absorbance at several wavelengths to locate the
maximum absorbance. Use this wavelength for subsequent measurements.
f. Measure the absorbance of the standard addition with the blank solution in the reference
cuvet. The absorbance of the standard addition will be ~0.45 absorbance units greater
than the absorbance of the unknown (based on adding ~0.50 mg of standard Mn2+ to the
unknown).
10. Repeat step 9 with the other unknown steel solution from step 7.
97
25. Measuring Mn in Steel by Spectrophotometric Standard Addition Quantitative Chemical Analysis
Data Analysis
1. From the known concentration of the Mn standard in step 4, calculate the concentration of
added Mn in the 50-mL volumetric flask containing the standard addition.
2. All of the Mn2+ is converted to MnO4- in step 9. From the difference between the absorbance
of the standard addition and the unknown, calculate the molar absorptivity of MnO4- .
Compute the average molar absorptivity from steps 9 and 10.
3. From the absorbance of each unknown and the average molar absorptivity of MnO4- ,
calculate the concentration of MnO4- in each 50-mL unknown solution.
4. Calculate the weight percent of Mn in each unknown steel sample and the percent relative
range of your results:
98
26. Measuring Mn in Steel by Atomic Absorption with a Calibration Curve Quantitative Chemical Analysis
Reagents
0.05 M Nitric acid: (600 mL/student) Dilute 3.2 mL of 70 wt% HNO3 to 1 L with water.
Unknown steel: Solutions A and B from step 8 of Experiment 25.
Standard manganese: ~0.1 mg Mn/mL from step 4 of Experiment 25. This concentration
corresponds to ~100 g/mL = ~100 ppm.
Calibration Curve
1. Prepare standard solutions containing ~1, 2, 3, 4 and 5 ppm Mn (= g Mn/mL). Use your
standard solution containing ~100 ppm Mn from step 4 of Experiment 25. Pipet 1.00 mL of
the standard into a 100-mL volumetric flask and dilute to 100 mL with 0.05 M HNO3 to
prepare a 1-ppm standard. Similarly, pipet 2.00, 3.00, 4.00, and 5.00 mL into the other flasks
and dilute each to 100 mL with 0.05 M HNO3. Calculate the concentration of Mn in g/mL
in each standard. (The purpose of the HNO3 is to provide H+ ions to compete with Mn2+
ions for binding sites on the glass surface. Without excess acid, some fraction of metal ions
from a dilute solution can be lost to the glass surface. To avoid adding impurity metal ions,
we use a dilute solution of the purest available acid.)
2. Measure the atomic absorption signal from each of the five standards in step 1. Use a Mn
hollow cathode lamp and a wavelength of 279.48 nm. Measure each standard three times.
42. Adapted from San Jose State University Laboratory Manual for a curriculum described by S. P. Perone, J.
Pesek, C. Stone, and P. Englert, J. Chem. Ed. 1998, 75, 1444.
99
26. Measuring Mn in Steel by Atomic Absorption with a Calibration Curve Quantitative Chemical Analysis
3. Measure the atomic absorption signal from a blank (0.05 M HNO3). We will use this signal
later to estimate the detection limit from Mn. For this purpose, measure a blank seven
separate times and compute the mean and standard deviation of the seven measurements.
1. Immediately after measuring the points on the calibration curve, measure the atomic
absorption signal from unknown steel solutions A and B from step 8 of Experiment 25.
Measure the absorption of each solution three times. (If the signals from A and B do not lie
in the calibration range, dilute them as necessary so that they do lie in the calibration range.
Dilutions must be done accurately with volumetric pipets and volumetric flasks.)
Data Analysis
1. Make a calibration graph showing the blank plus 5 standards (7 blank readings and 3 5 =
15 standard readings, for a total of n = 22 points). Compute the least-squares slope and
intercept and their standard deviations (Section 4-7 of the textbook) and show the least-
squares line on the graph. Express the equation of the calibration curve in the form y (sy) =
[m (sm)]x + [b (sb)], where y is the atomic absorbance signal and x is the concentration of
Mn in ppm.
2. Use the mean value of the three readings for each unknown to calculate the concentration of
Mn solutions A and B.
3. Calculate the uncertainty in Mn concentration in each unknown from Equation 4-27 in the
textbook. Because you have measured each unknown three times, the first term in the radical
in Equation 4-27 should be 1/3. In Equation 4-27, there are 22 values of xi for the points on
the standard curve.
4. From the Mn concentrations (and uncertainties) in solutions A and B, calculate the wt% Mn
(and its uncertainty) in the two replicate steel samples.
5. The uncertainty in wt% Mn is the standard deviation. Find the 95% confidence interval for
wt% Mn in each of the two steel samples that you analyzed. For example, suppose that you
find the wt% of Mn in steel to be 0.433, with a standard deviation of 0.011. (The subscripted
digits are not significant but are retained to avoid round-off errors.) The standard deviation
100
26. Measuring Mn in Steel by Atomic Absorption with a Calibration Curve Quantitative Chemical Analysis
was derived from three replicate measurements of one solution of dissolved steel. The
equation for confidence interval is = x- ts/ n , where is the true mean, x- is the
measured mean, s is the standard deviation, n is the number of measurements (3 in this case)
and t is Student's t for 95% confidence and n 1 = 2 degrees of freedom. In Table 4-2 of the
textbook we find t = 4.303. Therefore the 95% confidence interval is 0.433 ts/ n = 0.433
(4.303)(0.011)/ 3 = 0.433 0.027.
6. Use the t test (Equation 4-8 in the textbook) to compare the two atomic absorption results to
each other. Are they significantly different at the 95% confidence level?
7. Use the mean wt% Mn for the two samples and the pooled standard deviation (Equation 4-9
in the textbook) to estimate a 95% confidence interval around the mean value. Does the
mean spectrophotometric value for wt% Mn from Experiment 25 lie within the 95%
confidence interval for the atomic absorption results? (We cannot use the t test to compare
Experiments 25 and 26 because we do not have enough samples in Experiment 25 to find a
standard deviation. Otherwise, we would use the t test.)
8. Detection limit: The detection limit of an analytical method is the minimum concentration of
analyte that can be reliably distinguished from 0. Different statistical criteria for the word
reliably lead to different definitions of detection limit. If you have measured points on a
calibration curve, one common definition of detection limit is
y- B + 3sB
Detection limit (ppm) = m
where y- B is the mean atomic absorbance reading for the blank, sB is the standard deviation
for the blank, and m is the least-squares slope of the calibration curve (absorbance/ppm). In
this experiment you measured a blank solution seven times. Use the mean and standard
deviation from these seven readings to calculate the detection limit. (If you subtracted the
mean value of the blank from each absorbance reading when you constructed the standard
curve, then y- B = 0.)
101
27. Properties of an Ion-Exchange Resin Quantitative Chemical Analysis
In the first part of the experiment, known quantities of NaCl, Fe(NO3)3, and NaOH will be
passed through the resin in the H+ form. The H+ released by each cation will be measured by
titration with NaOH.
In the second part, we will analyze a sample of impure vanadyl sulfate (VOSO4.2H2O). As
supplied commercially, this salt contains VOSO4, H2SO4, and H2O. A solution will be prepared
from a known mass of reagent. The VO2+ content can be assayed spectrophotometrically, and
the total cation (VO2+ and H+) content can be assayed by ion exchange. Together, these
measurements enable us to establish the quantities of VOSO4, H2SO4, and H2O in the sample.
Reagents
0.3 M NaCl: A bottle containing 510 mL per student, with an accurately known concentration.
0.1 M Fe(NO3)3 . 6H2O: A bottle containing 510 mL per student, with an accurately known
concentration.
VOSO4: The commonly available grade (usually designated purified) is used for this
experiment. Students can make their own solutions and measure the absorbance at 750 nm,
43. Part of this experiment is taken from M. W. Olson and J. M. Crawford, J. Chem. Ed. 1975, 52, 546.
102
27. Properties of an Ion-Exchange Resin Quantitative Chemical Analysis
or a bottle of stock solution (25 mL per student) can be supplied. The stock should contain
8 g/L (accurately weighed) and be labeled with the absorbance.
0.02 M NaOH: Each student should prepare an accurate 1/5 dilution of standard 0.1 M NaOH.
Phenolphthalein indicator: Dissolve 50 mg of the indicator in 50 mL of ethanol and add
50 mL H2O.
Procedure
1. Prepare a chromatography column from a 0.7-cm diameter 15-cm length of glass tubing,
fitted at the bottom with a cork having a small hole that serves as the outlet. Place a small
ball of glass wool above the cork to retain the resin. Use a small glass rod to plug the outlet
and shut off the column. (Alternatively, an inexpensive column such as 0.7 15 cm Econo-
Column from Bio-Rad Laboratories44 works well in this experiment.) Fill the column with
water, close it off, and test for leaks. Then drain the water until 2 cm remains and close the
column again.
2. Make a slurry of 1.1 g of Bio-Rad Dowex 50W-X2 (100/200 mesh) cation-exchange resin in
5 mL of water and pour it into the column (Figure 1). If the resin cannot be poured all at
once, allow some to settle, remove the supernatant liquid with a pipet, and pour in the rest of
the resin. If the column is stored between laboratory periods, it should be upright, capped,
and contain water above the level of the resin. (When the experiment is finished, the resin
can be collected, washed with 1 M HCl and water, and reused.)
3. The general procedure for analysis of a sample is as follows:
a. Generate the H+-saturated resin by passing ~10 mL of 1 M HCl through the column.
Apply the liquid sample to the glass wall so as not to disturb the resin.
b. Wash the column with ~15 mL of water. Use the first few milliliters to wash the glass
walls and allow the water to soak into the resin before continuing the washing. (Unlike
most other chromatography resins, the one used in this experiment retains water when
allowed to run dry. Ordinarily, you must not let liquid fall below the top of the solid
phase in a chromatography column.)
c. Place a clean 125-mL flask under the outlet and pipet the sample onto the column.
103
27. Properties of an Ion-Exchange Resin Quantitative Chemical Analysis
Glass rod
Slurry of
solid Figure 1. Pouring a slurry
Slurry
phase and of stationary phase into a
poured
solvent chromatography column.
down wall
of column
Solvent in
bottom of
column
before slurry
Porous disk
is poured
Outlet
clamped
shut
d. After the reagent has soaked in, wash it through with 10 mL of H2O, collecting all eluate.
e. Add 3 drops of phenolphthalein to the flask and titrate with standard 0.02 M NaOH.
4. Analyze 2.000-mL aliquots of 0.3 M NaCl and 0.1 M Fe(NO3)3, following the procedures in
step 3. Calculate the theoretical volume of NaOH needed for each titration. If you do not
come within 2% of this volume, repeat the analysis.
5. Pass 10.0 mL of your 0.02 M NaOH through the column as in step 3, and analyze the eluate.
Explain what you observe.
6. Analyze 10.00 mL of VOSO4 solution as described in step 3.
7. Using the molar absorptivity of vanadyl ion ( = 18.0 M-1.cm-1 at 750 nm) and the results of
step 6, express the composition of the vanadyl sulfate in the form
(VOSO4)1.00(H2SO4)x(H2O)y.
104
28. Analysis of Sulfur in Coal by Ion Chromatography Quantitative Chemical Analysis
Reagents
Coal: 1g/student. Coal can be obtained from electric power companies and some heavy
industries. Coal is also available as a Standard Reference Material.46
Flux: 4 g/student. 67 wt% MgO/33 wt% Na2CO3.
6 M HCl: 25 mL/student.
Phenolphthalein indicator: Dissolve 50 mg of solid indicator in 50 mL of ethanol and
add 50 mL H2O.
Ammonium sulfate: Solid reagent for preparing standards.
Procedure
1. Grind the coal to a fine powder with a mortar and pestle. Mix 1 g of coal (accurately
weighed) with ~3 g of flux in a porcelain crucible. Mix thoroughly with a spatula and tap
the crucible to pack the powder. Gently cover the mixture with ~1g of additional flux.
Cover the crucible and place it in a muffle furnace. Then turn on the furnace and set the
temperature to 800 C and leave the sample in the furnace at 800 C overnight. The reaction
105
28. Analysis of Sulfur in Coal by Ion Chromatography Quantitative Chemical Analysis
is over when all black particles have disappeared. A burner can be used in place of the
furnace, but the burner should not be left unattended overnight.
2. After cooling to room temperature, place the crucible into a 150-mL beaker and add 100 mL
of distilled water. Heat the beaker on a hot plate to just below boiling for 20 min to dissolve
as much solid as possible. Pour the liquid through filter paper in a conical funnel directly
into a 250-mL volumetric flask. Wash the crucible and beaker three times with 25-mL
portions of distilled water and pour the washings through the filter. Add 5 drops of
phenolphthalein indicator to the flask and neutralize with 6 M HCl until the pink color
disappears. Dilute to 250 mL and mix well.
3. Pipet 25.00 mL of sulfate solution from the 250-mL volumetric flask in step 2 into a
100-mL volumetric flask and dilute to volume to prepare a fourfold dilution for ion
chromatography. Inject a sample of this solution into an ion chromatograph47 to be sure
that the concentration is in a reasonable range for analysis. More or less dilution may be
necessary. Prepare the correct dilution for your equipment.
4. Assuming that the coal contains 3 wt% sulfur, calculate the concentration of SO2-
4 in the
solution in step 3. Using ammonium sulfate and appropriate volumetric glassware, prepare
five standards containing 0.1, 0.5, 1.0, 1.5, and 2.0 times the calculated concentration of
SO2-
4 in the unknown.
5. Analyze all solutions by ion chromatography. Prepare a calibration curve from the
standards, plotting peak area versus SO2-
4 concentration. Use the least-squares fit to find the
concentration of SO2-
4 in the unknown. Calculate the wt% of S in the coal.
47. For example, chromatography can be done with 25-50 L of sample on a 4-mm-diameter 250-mm-long
Dionex Ionpac AS5 analytical column and an AG5 guard column using 2.2 mM Na2CO3/2.8 mM NaHCO3
eluent at 2.0 mL/min with ion suppression. SO2
4 is eluted near 6 min and is detected by its conductivity on a
full-scale setting of 30 microsiemens. Many combinations of column and eluent are suitable for this analysis.
106
29. Measuring CO in Automobile Exhaust by Gas Chromatography Quantitative Chemical Analysis
Reagents
Reagents
1. Attach with heavy tape a heat-resistant hose to the exhaust pipe of a car. (Caution: Avoid
breathing the exhaust.) Use the free end of the hose to collect exhaust in a heavy-walled,
0.5-L plastic zipper-type bag from the grocery. Flush the bag well with exhaust before
sealing it tightly. Allow the contents to come to room temperature for analysis.
2. Inject a 1-mL sample of air into the gas chromatograph by using a gas-tight syringe and
adjust the temperature and/or flow rate if necessary so that N2 is eluted within 2 min. You
should see peaks for O2 and N2.
107
29. Measuring CO in Automobile Exhaust by Gas Chromatography Quantitative Chemical Analysis
3. Inject 1.00-mL of standard 1 vol% CO in N2. One way to obtain gas from a lecture bottle is
to attach a hose to the tank (in a hood) with a serum stopper on a glass tube at the end of the
hose (Figure 1). Place a needle in the serum stopper and slowly bleed gas from the tank to
flush the hose. Insert a gas-tight syringe into the serum stopper, remove the vent needle, and
slowly withdraw gas into the syringe. Then close the tank to prevent pressure buildup in the
tubing. When you inject the standard into the chromatograph, you should see a peak for CO
with about three times the retention time of N2. Adjust the detector attenuation so the CO
peak is near full scale. Reinject the standard twice and measure the peak area each time.
Figure 1. Collecting a sample of standard gas mixture from a lecture bottle. Remove the vent
needle when withdrawing gas into the syringe. Do not open the tank valve so much that the
connections pop open. (CAUTION: Handle CO only in a hood.)
4. Inject two 1.00-mL samples of auto exhaust and measure the peak area each time. Compute
the vol% of CO in the unknown from its average peak area:
108
30. Amino Acid Analysis by Capillary Electrophoresis Quantitative Chemical Analysis
In this experiment you will hydrolyze a protein with HCl to break the
protein into its component amino acids. After the addition of an internal
standard, the amino acids and the internal standard will be derivatized
(chemically converted) to a form that absorbs light strongly at 420 nm.
Green Profile
See Section 0 CN
O CN-
+ H2NCHRCO2- N CHRCO2-
O
The mixture will then be separated by capillary electrophoresis, and the quantity of each
component will be measured relative to that of the internal standard. The goal is to find the
relative number of each amino acid in the protein.
Reagents
Protein: 6 mg/student. Use a pure protein such as lysozyme or cytochrome c. The amino acid
content should be available in the literature for you to compare with your results.51
6 M HCI: Dilute 124 mL of concentrated (37 wt%) HCl up to 250 mL with distilled water.
0.05 M NaOH: Dissolve 0.50 g of NaOH (FM 40.00) in 250 mL of distilled water.
1.5 M NH3: Dilute 26 mL of 28 wt% NH3 up to 250 mL with distilled water.
10 mM KCN: Dissolve 16 mg of KCN (FM 65.12) in 25 mL of distilled water.
S10T7H1G12A12(E2Q3)Y3(D8N13)V6M2I6L8F3R11K6C8W8P2
(R. E. Canfield and A. K. Liu, J. Biol. Chem. 1965, 240, 2000; D. C. Philips, Scientific American, May 1966.)
For horse cytochrome c, the composition is
S0T10H3G12A6(E9Q3)Y4(D3N5)V3M2I6L6F4R2Kl9C2W1P4
(E. Margoliash and A. Schejter, Adv. Protein Chem. 1966, 21, 114.) Both proteins are available from
www.sigmaaldrich.com.
109
30. Amino Acid Analysis by Capillary Electrophoresis Quantitative Chemical Analysis
Borate buffer (pH 9.0): To prepare 20 mM buffer, dissolve 0.19 g of sodium tetraborate
(Na2B4O7 . 10H2O, FM 381.37) in 70 mL of distilled water. Using a pH electrode, adjust
the pH to 9.0 with 0.3 M HCl (a 1:20 dilution of 6 M HCl with distilled water) and dilute to
100 mL with distilled water.
Run buffer (20 mM borate50 mM sodium dodecyl sulfate, pH 9.0): Prepare this as you
prepared borate buffer but add 1.44 g of CH3(CH2)11OSO3Na (FM 288.38) prior to adjusting
the pH with HCl.
Amino acids: Prepare 100 mL of standard solution containing all 15 of the amino acids in Figure
1, each at a concentration near 2.5 mM in a solvent of 0.05 M NaOH. Table 9-1in the
textbook gives molecular masses of amino acids.
110
30. Amino Acid Analysis by Capillary Electrophoresis Quantitative Chemical Analysis
1. Fit a rubber septum onto a glass tube (17 55 mm) that is sealed at one end and evacuate it
through a needle. Dissolve 6 mg of protein in 0.5 mL of 6 M HCl in a small vial. Purge the
solution with N2 for 1 min to remove O2 and immediately transfer the liquid by syringe into
the evacuated tube. Add 0.5 mL of fresh HCl to the vial, purge, and transfer again into the
tube. Heat the part of the glass tube containing the liquid at 100l10C in an oil bath for
18-24 h, preferably behind a shield.
2. After cooling, remove the septum and transfer the liquid to a 25-mL round-bottom flask.
Evaporate the solution to dryness with gentle heat and suction from a water aspirator. Use a
trap like that in Figure 2-17 in the textbook whenever you use an aspirator. Rinse the
hydrolysis tube with 1 mL of distilled water, add it to the flask, and evaporate to dryness
again. Dissolve the residue in 1.0 mL of 0.05 M NaOH and filter it through a 0.45-m pore
size syringe filter. The total concentration of all amino acids in this solution is ~50 mM.
Derivatization
3. Using a micropipet, place 345 L of 20 mM borate buffer into a small screw-cap vial. Add
10 L of the standard amino acid solution. Then add 10 L of 5 mM -aminoadipic acid
(the internal standard), 90 L of 10 mM KCN, and 75 L of 10 mM naphthalene-2,3-dicar-
boxaldehyde. The fluorescent yellow-green color of the amino acid-NDA product should
appear within minutes. After 25 min, add 25 L of 1.5 M NH3 to react with excess NDA.
Wait 15 min before electrophoresis.
4. Place 345 L of 20 mM borate buffer (pH 9.0) into a small screw-cap vial. Add 10 L of the
hydrolyzed protein solution in 0.05 M NaOH from step 2. Then add 10 L of 5 mM
-aminoadipic acid (the internal standard), 60 L of 10 mM KCN, and 50 L of 10 mM
naphthalene-2,3-dicarboxaldehyde. After 25 min, add 25 L of 1.5 M NH3 to react with
111
30. Amino Acid Analysis by Capillary Electrophoresis Quantitative Chemical Analysis
excess NDA. After 15 min, begin electrophoresis. (Precise timing reduces variations
between the standard and the unknown.)
5. (Caution: Electrophoresis uses a dangerously high voltage of 20-24 kV. Be sure to follow all
safety procedures.) Electrophoresis is conducted with a 50-m-inner-diameter uncoated
silica capillary and spectrophotometric detection at 420 nm. Precondition the column by
injecting 30 L of 0.1 M NaOH and flushing 15 min later with 30 L each of distilled water
and then run buffer. The column should be reconditioned in the same manner after every 3-4
runs.
6. Inject 3 nL of standard amino acid mixture from step 3. The electropherogram should look
similar to Figure 1. Measure the area of each peak (or the height, if you do not have a
computer for measurement of area). Repeat the injection and measure the areas again.
7. Find the quotient
for each amino acid in the standard mixture. (Use peak heights if area is not available.)
Prepare a table showing the relative areas for each peak in each injection of standard and find
the average quotient for each amino acid from both runs.
8. Inject 3 nL of derivatized, hydrolyzed protein from step 4 and measure the same quotient as
measured in step 7. Repeat the injection and find the average quotient from both injections.
9. You know the concentration of internal standard in the protein hydrolysate from the volume
and concentration of internal standard used in step 4. Find the concentration of each amino
acid in the protein hydrolysate by using Equation 5-11 in the textbook.
10. Find the mole ratio of amino acids in the protein. If there were no experimental error, you
could divide all concentrations by the lowest one. Because the lowest concentration has a
large relative error, pick an amino acid with two or three times the concentration of the least
concentrated amino acid. Define this concentration to be exactly 2 or 3. Then compute the
molarities of other amino acids relative to the chosen amino acid. Your result is a formula
such as S10.6T6.6H0.82G12.5A11.2E5.3Y3D19.8V6.1M2.2I5.7(L + F)11.5.
112
31. DNA Composition by High-Performance Liquid Chromatography Quantitative Chemical Analysis
H
O N NH2 O N O
O OH
P O N O
H2 O3 POCH2 N
HO O
Cytosine
HO HO
Deoxyribose
N NH2 N O
O O
H2 O3 POCH2 N H2 O3 POCH2 N
N N
N N
HO HO NH2
113
31. DNA Composition by High-Performance Liquid Chromatography Quantitative Chemical Analysis
Reagents
Standard nucleotide solution: The standard should contain accurately weighed quantities of the
nucleotide monophosphates53 at concentrations of ~20 mM. The molecular masses of the free
acids are C - 307.2, T - 322.2, A - 331.2, G - 347.2. Place the required quantities of the solid
acids in a 5-mL volumetric flask and add 2 mL of water and 1.6 mL of 0.10 M NaOH (2 mol
NaOH per mol of nucleotide). Dissolve the solid, dilute to the mark with water, mix well, and
store the standard in a refrigerator. (The volume of the standard changes when it is cooled, but
this is not important. Only the relative concentrations of nucleotides in the standard are
important in this experiment.)
Hydrolyzed DNA: The volumes of DNA and nuclease P1 solutions should be the minimum
required for the number of people doing the experiment. Prepare a solution containing 1
mg/mL of calf thymus (or other) DNA.53 Dissociate the DNA into single strands by heating at
100C for 10 min and then cooling immediately on ice. Prepare nuclease P153 at a final
concentration of 5 units/mL54 in 50 mM sodium acetate buffer (pH 5.3) containing 0.6 mM
ZnCl2. Mix 20 L of DNA solution with 20 L of nuclease solution in a small vial with a
conical bottom. Heat the vial at 50C for 1 h and analyze it immediately or store it in the
refrigerator.
HPLC Eluent: Prepare 0.010 M potassium phosphate buffer by dissolving 0.010 mol K2HPO4
in 800 mL of water, titrating with ~1 M HCl to pH 7.2, and diluting to 1.00 L.
Chromatography
53. www.sigmaaldrich.com
54. For nuclease P1, one unit is defined as the amount that will liberate 1.0 mol of acid soluble nucleotides from
yeast ribonucleic acid per min at pH 5.3 at 37C. The commercial preparation has at least 200 units/mg of
nuclease P1.
114
31. DNA Composition by High-Performance Liquid Chromatography Quantitative Chemical Analysis
preferably by computer integration. Alternatively, you can estimate peak area from the
formula: area of Gaussian peak = 1.064 peak height w1/2, where w1/2 is the width at half-
height. Express the areas of C, T, and A relative to the area of G, which we will define as
1.000. Repeat the procedure with a second injection and measure the relative areas. List the
relative peak areas in each run and the average of the two runs.
3. Inject 10 L of hydrolyzed DNA and measure the relative areas of the peaks. Repeat the
process a second time. List the relative areas in each run and the average of the two runs.
Calculations
1. From the average peak areas of the two standard runs, find the response factors for C, T, and
A relative to G. For example, the response factor for C is obtained from the equation
area of C area of G
= F
concentration of C concentration of G
AC AG
= F [G]
[C]
There will be similar equations for T, and A. We are using G as the internal standard.
2. From the average peak areas of the two injections of hydrolyzed DNA, find the relative
concentrations [C]/[G], [T]/[G], and [A]/[G] by using the response factors from the standard
mixture. What is the theoretical value of [C]/[G]? What is the theoretical relationship
between [T]/[G] and [A]/[G]?
3. Find the fraction of nucleotides that are C + G by evaluating the expression
[C] [G]
[G] + [G]
Fraction [C] + [G]
of C + G: [C] + [G] + [A] + [T] = [C] [G] [A] [T]
[G] + [G] + [G] + [G]
For calf thymus DNA, the literature value of the fraction of C + G is 0.42.
115
32. Analysis of Analgesic Tablets by High-Performance Liquid Chromatography Quantitative Chemical Analysis
OH
O CH3 CO 2H
H3C N
N O O
O N N CH3
H3C NH
CH 3
O
Caffeine Aspirin Acetaminophen
(acetylsalicylic acid)
Reagents
HPLC solvent: Organic solvents should be handled in a fume hood. All solvents in this
experiment should be HPLC-grade. Mix 110 mL of acetonitrile, 4.0 mL of triethylamine, and
4.0 mL of acetic acid in a 2-L volumetric flask and dilute to the mark with HPLC-grade water.
Filter through a 0.45-m filter and store in a tightly capped amber bottle.
Caffeine stock solution (100 g/mL): Dissolve 1.000 g of caffeine in 50 mL of HPLC solvent in
a 100-mL volumetric flask with gentle heating (in the hood). Cool to room temperature and
dilute to the mark with HPLC solvent. Dilute 10.00 mL to 100 mL with HPLC solvent in a
volumetric flask to obtain 1 000 g/mL. Dilute once again to obtain 100 g/mL.
Acetaminophen and aspirin samples: Prepare two solutions, each containing one of the analytes
at a concentration of ~50 g/mL in HPLC solvent. Filter through 0.22 m nylon syringe
filters and store in capped amber bottles.
116
32. Analysis of Analgesic Tablets by High-Performance Liquid Chromatography Quantitative Chemical Analysis
Procedure
1. Caffeine quantitative analysis standards: Dilute the 100 g/mL stock solution down to 50,
10, and 5 g/mL with HPLC solvent. Filter ~3 mL of each solution through a 0.22-m
syringe filter into a capped vial. Filter ~3 mL of the 100 g/mL solution into a fourth vial.
2. Sample preparation: Grind the analgesic tablet into a fine powder with a clean mortar and
pestle. Dissolve ~0.5 g (weighed accurately) in 50 mL of HPLC solvent with gentle
heating. Cool to room temperature and dilute to volume with HPLC solvent. Dilute 10.00
mL of this solution to 100 mL with HPLC solvent in a volumetric flask. Filter ~3 mL of the
dilute solution through a 0.22-m syringe filter into a capped vial.
3. Chromatography conditions: Use a 2.1-mm-diameter 10-cm-long C18-silica column with
5-m particle size and ultraviolet detection at 254 nm. With a flow rate of 1.5 mL/min, each
run is complete in 4 min.
4. Calibration curve: Inject 10 L of each of the caffeine standards (5, 10, 50, and 100
g/mL) into the HPLC and measure the peak area. Repeat this process twice more and use
the average areas from the three runs to construct a calibration curve of area versus
concentration. Compute the least-squares slope and intercept for the line through points.
5. Qualitative analysis: Record a chromatogram of 10 L of the analgesic tablet solution.
Then mix 2 drops of the tablet solution with 2 drops of 50 g/mL caffeine solution in a test
tube or vial. Inject 10 L of the mixture into the chromatograph and observe which peak
grows. Repeat the process again by adding 50 g/mL acetaminophen and 50 g/mL aspirin
and identify which peaks in the analgesic are acetaminophen and aspirin.
6. Quantitative analysis: Inject 10 L of the analgesic tablet solution and measure the area of
the caffeine peak. Repeat this process twice more and take the average from three
injections. Using your calibration graph, determine the concentration of caffeine in the
solution and the weight percent of caffeine in the original tablet.
117
33. Anion Content of Drinking Water by Capillary Electrophoresis Quantitative Chemical Analysis
Chloride, sulfate, and nitrate are the major anions in fresh water. Fluoride
is a minor species added to some drinking water at a level near 1.6 ppm to
help prevent tooth decay. In this experiment, you will measure the three
major anions by capillary electrophoresis. Possible class projects are to
compare water from different sources (homes, lakes, rivers, ocean) and
Green Profile
See Section 0 various bottled drinking waters.
Your equipment should be similar to that in Figure 25-22 in the
textbook. Convenient capillary dimensions are a diameter of 75 m and a length of 40 cm from
the inlet to the detector (total length = 50 cm). Because the anions have little ultraviolet
absorbance at wavelengths above 200 nm, we add chromate anion (CrO2-
4 ) to the buffer and use
indirect ultraviolet detection at 254 nm. The principle of indirect detection is explained in
Figure 25-35.
One other significant condition for a successful separation in this experiment is to reduce
the electroosmotic flow rate to permit a better separation of the anions based on their different
electrophoretic mobilities. At pH 8, electroosmotic flow is so fast that the anions are swept from
the injector to the detector too quickly to be separated well from one another. To reduce the
electroosmotic flow, we could lower the pH to protonate some of the O- groups on the wall.
Alternatively, what we do in this experiment is to add the cationic surfactant tetradecyl-
+
(trimethyl)ammonium ion, CH3(CH2)13N(CH3)3, which is attracted to the O- groups on the
wall and partially neutralizes the negative charge of the wall. This cationic surfactant is
abbreviated OFM+, for osmotic flow modifier.
Reagents
56. S. Demay, A. Martin-Girardequ, and M.-F. Gonnord, J. Chem. Ed. 1999, 76, 812.
57. 100 mM tetradecyl(trimethyl)ammonium hydroxide (Catalog number WAT049387) is available from
www.waters.com. The surfactant trade name is Osmotic Flow Modifier, abbreviated OFM+OH.
118
33. Anion Content of Drinking Water by Capillary Electrophoresis Quantitative Chemical Analysis
HPLC-grade H2O. Place a pH electrode in the solution and add solid boric acid (H3BO3)
(with magnetic stirring) to reduce the pH to 8.0. Dilute to 1.00 L with HPLC-grade H2O, mix
well, filter through a 0.45-m filter, and store in the refrigerator in a tightly capped plastic
bottle. Degas prior to use.
Quantitative standards: Prepare one stock solution containing 1 000 ppm Cl-, 1 000 ppm NO3- ,
and 1 000 ppm SO2-
4 by dissolving the following salts in 1.000 L of HPLC-grade H2O: 2.103
g KCl (FM 74.55), 1.631 g KNO3 (FM 101.10), and 1.814 g K2SO4 (FM 174.26).
(Concentration refers to the mass of the anion. For example, 1 000 ppm sulfate means 1 000
g of SO2-
4 per mL of solution, not 1 000 g of K2SO4.) Dilute the stock solution with
HPLC-grade H2O to make standards with concentrations of 2, 5, 10, 20, 50, and 100 ppm of
the anions. Store the solutions in tightly capped plastic bottles.
Standards for qualitative analysis: Prepare four separate 1.00-L solutions, each containing just
one anion at a concentration of ~50 ppm. To do this, dissolve ~0.105 g KCl, ~0.082 g KNO3,
~0.091 g K2SO4, or ~0.153 g KF (FM 58.10) in 1.00 L.
Procedure
0. CAUTION: Electrophoresis uses a dangerously high voltage. Be sure to follow all safety
procedures for the instrument.
1. When preparing a capillary for its first use, wash through 1 M NaOH for 15 min, followed
by 0.1 M NaOH for 15 min, followed by run buffer for 15 min. In this experiment, wash the
column with run buffer for 1 min between sample injections.
2. Identify the peaks: Inject a 50 ppm mixture of Cl-, NO3- , and SO2-
4 by applying a pressure
of 0.3 bar for 5 s. Then insert the sample end of the capillary back in run buffer and perform
a separation for 5 min at 10 kV with the capillary thermostatted near 25C. The voltage
should be positive at the injector and negative at the detector. The detector should be set at
254 nm. After the run, wash the column with run buffer for 1 min. Mix the 50 ppm anion
mixture with an equal volume of 50 ppm Cl- and run an electropherogram of the mixture.
The Cl- peak should be twice the size it was in the first run. Repeat the procedure with
additions of NO3- , SO2- -
4 , and F . This process tells you which peak belongs to each anion
and where to look for F- in drinking water.
119
33. Anion Content of Drinking Water by Capillary Electrophoresis Quantitative Chemical Analysis
3. Calibration curves: Inject each of the standard mixtures from lowest concentration to
highest concentration (2, 5, 10, 20, 50, and 100 ppm) and measure the area of each peak in
each run. Repeat the sequence twice more and use the average peak area at each
concentration to construct a calibration curve for each anion. Find the least-squares straight
line to fit the graph of area versus concentration for each anion.
4. Unknowns: Make three replicate injections of each unknown water sample and measure the
areas of the peaks. Use the average area of each peak and the calibration curves to find the
concentrations of the anions in the water. If you analyze any saltwater samples, they should
be diluted by a factor of 100 with HPLC-grade water to bring the anion concentrations down
to the range of fresh waters.
120
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil Quantitative Chemical Analysis
58 Adapted from L. C. McKenzie, J. E. Thompson, R. Sullivan, and J. E. Hutchison, Green Chem. 2004, 6, 355.
59 Experiment contributed by Douglas E. Raynie, Department of Chemistry and Biochemistry, South Dakota State
University, Brookings SD 57007; douglas.raynie@sdstate.edu.
121
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil Quantitative Chemical Analysis
Figure 1. Phase
diagram for CO2.
A supercritical fluid might act as a liquid solvent to dissolve solutes, yet maintains
viscosity and diffusion properties similar to those of a gas. Supercritical CO2 has advantages for
extracting essential oils from flowers, fruit rind, and other products. Supercritical CO2 is
nonflammable, relatively nontoxic, and readily available. To perform a supercritical extraction,
an instrument is needed to heat and pressurize CO2 above its critical point (31C and 74 bar).
To mimic a true supercritical fluid extraction, we will use liquid CO2, which has
properties similar to the supercritical fluid. Dry Ice sublimes at atmospheric pressure and
temperatures above 78C. If CO2 is sealed in a vessel during sublimation, the pressure in the
vessel increases. After the temperature and pressure have increased sufficiently, liquid CO2
forms. We can exploit the ease of CO2 liquefaction to extract essential oils from citrus rind.
60 Instead of lemon peel, you may chose to use orange peel. Orange oil will be about 95% D-limonene, which is
sufficiently pure to characterize by infrared spectroscoy and nuclear magnetic resonance.
122
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil Quantitative Chemical Analysis
500-mL plastic graduated cylinder or wide-mouth polycarbonate jar: one per student.
Alternatively, construct a watertight cylinder from a 30-cm-long clear plastic tube with a 25-
mm diameter and 3-mm wall thickness cemented to a flat plastic base with silicone calk.
Filter paper: one 1.5-cm-diameter circle of Whatman #1 filter paper per student
Thermometer: Several students can share a single thermometer to measure water at 4050C.
Forceps: Several students can share a single pair of forceps capable of reaching into the cylinder
to remove the centrifuge tube.
Tweezers: Several students can share a single pair.
Pasteur pipet: One per student.
Safety Precautions
0. Pressure generated during this experiment creates a risk of flying plastic centrifuge caps and
rupture of plastic vessels. The source for this procedure58 reports that caps blew off in 4% of
all experiments, so you can EXPECT this to happen in your laboratory. Under no
circumstance should vessels other than the recommended ones be used..
1. Do not use any glass in this experiment. Substitution of glass centrifuge tubes or graduated
cylinders could result in serious injuries if shattering should occur.
2. Always wear eye protection.
3. Use gloves when handling dry ice. Contact with dry ice can damage your skin.
4. Do not liquefy CO2 more than 5 times in the same centrifuge tube. After repeated
liquefaction, the tube may become brittle and rupture.
Procedure
0. Read safety precautions and the entire procedure before beginning the experiment.
1. Verify that the cap fits tightly on the centrifuge tube. If the cap does not stop turning when
you screw it down, try a different cap or different tube. Unscrew the cap and put it aside.
2. Following Figure 2, coil the copper wire into 3 circles on one end and leave the other end
straight. The coils should fit into the centrifuge tube and rest above the tapered section of the
tube. The straight section of wire should be contained within the tube when the cap is
screwed on. Place a small circle of filter paper between the coils so that the filter paper will
support the solid to be extracted. Insert the coil with its filter paper into the centrifuge tube.
123
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil Quantitative Chemical Analysis
Coiled Circle of
wire filter paper Wire and filter
supported Add orange Add crushed
paper in plastic
in coil or lemon rind Dry Ice and
centrifuge tube cap tightly
Suspend tube in plastic
cylinder of water
3. Add ~2.5 g of grated lemon peel to the tube, but do not pack tightly. The peel should rest on
the filter paper. During extraction, liquid CO2 must penetrate the loosely packed peel and
reach the bottom tip of the centrifuge tube.
4. Fill the 500-mL plastic cylinder or wide-mouth polycarbonate water bottle one-half to two-
thirds full of warm tap water at 40-50C. Do not heat the cylinder or add hot water at any
time later in the experiment, or the cap can blow off the centrifuge tube during the extraction.
5. Wearing gloves and using a scoop or small beaker, fill the centrifuge tube with crushed Dry
Ice. Tap the tube on the lab bench and add more Dry Ice to fill the tube. Take the cap that
you have already tested for a tight fit and screw it tight. If the seal is not tight, try a different
cap or, if necessary, start again with a different tube and cap.
6. Place the centrifuge tube with the tapered end down into the cylinder or plastic jar of warm
water. Sublimation of Dry Ice will build high pressure inside the tube and liquid CO2 will
appear in about 15 seconds. Even though the cap is tight, gas will escape through the
threads.
7. View the boiling CO2 in the centrifuge tube from the side of the cylinder. Do not look into
the top of the cylinder. If the cap blows, it will fly straight up and hit you in the face.
8. If liquid CO2 does not appear within a minute, the seal is not tight enough to maintain
sufficient pressure in the centrifuge tube. Take the tube out of the cylinder with forceps,
124
34. Green Chemistry: Liquid Carbon Dioxide Extraction of Lemon Peel Oil Quantitative Chemical Analysis
tighten the cap, and place it back in the warm water. If liquid CO2 does not appear after
several attempts to tighten the cap, try a different cap. If necessary, begin again with a fresh
combination of tube and cap. 61
9. When the cap is tight, liquid will appear in the tube and gas will slowly escape through the
threads. Slowly rotate the cylinder so that the cold centrifuge tube does not freeze to the
cylinder wall. Do not remove the centrifuge tube from the cylinder while liquid CO2 is
present. The cylinder protects you in case the pressurized centrifuge tube explodes.
10. Liquid CO2 in the centrifuge tube boils vigorously and extracts essential oil from the lemon
peel. After a few minutes, CO2 will have escaped from the tube and no liquid will be left.
Approximately 0.1 mL of pale yellow oil should be visible at the bottom of the centrifuge
tube. If the tube is packed too tightly with lemon peel, liquid CO2 cannot reach the tip of the
tube and extracted oil will not collect at the tip.
11. When no liquid CO2 is left in the centrifuge tube, remove the tube from the cylinder with
forceps and unscrew the cap slightly to allow the remaining pressure to escape. After all
pressure has been released, it is safe to remove the cap. Using tweezers, carefully pull the
wire from the tube to remove the lemon peel.
12. Transfer the extracted oil by Pasteur pipet into a gas chromatography autosampler vial and
dilute with methanol. Use gas chromatographymass spectrometry to compare your extract
to a commercial sample of lemon oil. We recommend a DB-5 or other 5% phenyl, nonpolar
column with a 10C/min temperature gradient. Extracted lemon oil will have about six major
components.
13. As part of your lab report, identify the major peaks in the chromatogram from their mass
spectra. Perform a literature search on supercritical fluid extraction. (a) Find one reference
to the use of supercritical fluid extraction in the flavor and fragrance industry. (b) Aside
from essential oils, what types of compounds are commonly extracted via supercritical fluid
extraction? (c) Identify a vendor of supercritical fluid extraction equipment.62
61 In some cases, CO2 might not liquefy or no extract is visible. If the centrifuge tube is rinsed with a small amount
of methanol, enough extract to be observed via gas chromatographymass spectrometry is usually obtained.
62 Instructors: The University of Oregon Greener Education Materials for Chemists database
(http://greenchem.uoregon.edu/Pages/Overview.php?CategoryIDString=&FullTextSearchKeywords=orange&C
ategoriesToSearch=&NumberOfMainCategories=7&AnyAll=Any&ID=85) contains comments from people
who have used this experiment and allows you to add comments from your experience.
125