Registered To: Ilham, polban VALVE TRAY RATING DATA

Project Name Date : 23-Dec-2017 Page : 1


Tower Name tw5502 File : polban
Case Name By : Revision :
ZONE
DESCRIPTION
TRAY NUMBER 1 MIN MAX
% OF LOADING 100 40 150
LOADINGS
Vapor Rate kg/hr 56108 22443 84162
Vapor Density kg/m3 17,800 17,800 17,800
Vapor Volume m3/s 0,88 0,35 1,31
Vapor Viscosity cP 0,0113 0,0113 0,0113
Liquid Rate kg/hr 24937 9975 37406
Liquid Density kg/m3 868,00 868,00 868,00
Liquid Volume m3/hr 28,73 11,49 43,09
Surface Tension mN/m 13,00 13,00 13,00
Liquid Viscosity cP 0,148 0,148 0,148

Tray Spacing mm 460,00 460,00 460,00


System Factor 1,00 1,00 1,00
Jet Flood % 35 14 52
Downcomer Flood % 8 3 12
Downcomer Backup mm liq 85,4 73,4 118,8
Downcomer Exit Velocity m/s 0,066 0,026 0,099
Dry Tray Pressure Drop mm liq 35,6 22,9 78,7
Total Tray Pressure Drop mm liq 59,8 47,8 97,1
Total Tray Pressure Drop mm Hg 3,8 3,1 6,2
Cf Active Area m/s 0,04 0,02 0,06
Weir Load m3/h/m 9,0 3,6 13,6
Weir Crest mm liq 12,3 6,7 16,1
Downcomer Backup % (TS+W) 16,7 14,4 23,3
Head Loss Under DC mm liq 0,7 0,1 1,6
DC Residence Time sec 42,9 107,3 28,6
DC Loading m3/hr/m2 44,0 17,6 66,0
Blow Rating % 50 20 76
System Limit % 21 9 32
Turndown % 56 139 37
Unit Reference % 102 41 153
Equation 13 % 35 14 52
WARNINGS: 1,

WARNINGS: 1. Weir load is under design limit. Please contact Koch-Glitsch.

The information contained herein is the confidential and proprietary property of Koch-Glitsch, LP and/or its affiliates ("Koch-Glitsch").
This information and any derivatives thereof are the exclusive property of Koch-Glitsch. This information is believed to be accurate and reliable
but is not to be as implying any warranty or guarantee of performance. The KG-TOWER® Software that generated this report may not be used by
or exported or re-exported to any U.S. embargoed country (currently Cuba, Iran, Syria, Sudan, and North Korea), a national or resident
of such countries, or on the U.S. Treasury Department's list of Specially Designated Nationals. You are solely responsible for compliance
with U.S. economic and trade sanctions. Refer to the License Agreement for additional information.

You might also like