GE Power

F-class Enhanced Compressor


Inspections and Maintenance
Enhancement Benefits Maintenance Removed
• The enhanced compressor system provides for increased Occasional Maintenance Pkg1 Pkg2 Pkg3 Pkg4 Pkg5
robustness and damage tolerance RO UT Inspections — X X X X
— Increased design margins/durability – reduced risks from RO LE Mold Inspection† — X X X X
unobserved/unmitigated degradation effects RO LE Blending — X X X X
— Increased reliability/availability through reduced unplanned RO Replacements — X X X X
and emergent maintenance RO Periodic NDT† — X X X X
— No intended or resultant performance impacts RO Trip Grinding — X X X X
R1 Trip Grinding — — X X X
• Reduced unplanned maintenance, depending on selected package FWD Stator Replacements — — X X X
— R0 replacements (inlet jacking/removal) Aft Stator Periodic BI† — — — X X
— Forward stator replacements (casing/rotor removal) Aft Stator Replacement — — — X X
— Aft stator replacements/patch ring repairs (casing/rotor removal) Aft Stator Patch Ring — — — X X
— R0/R1 tip grinding/blend repairs (casing removal) R1 UT Inspections — — — — X
— Degradation/damage repairs (casing removal, sometimes † Fleet leader inspections may apply.
rotor removal/rebuild)

• Reduced emergent work maintenance/operating restrictions, Fleet Leader Inspections


depending on selected package • Some special inspections beyond the standard shall continue for
— R0 erosion mold inspections (TIL 1603) units undergoing enhancement during the introductory period
— R0 wet operation restrictions (TIL 1603) (approximately the first 30 units receiving packages 2-5)
— R0 erosion blend repairs (TIL 1603) — R0 erosion molds at annual intervals up to first CI – no
— R0/R1 UT inspections (TIL 1638) blending requirement, no operational restrictions
— R0/R1 NDT inspections (TIL 1509) — R0 NDT per TIL 1509 following first year of enhanced
— Aft stator recurrent borescope inspections operation (12 months) – no blending requirement, no
— Stator shim migration/pinning (TIL 1562) operational restrictions
— Aft stator borescope inspections for any unit previously
Standard Inspections experiencing S14-S16 rocking, approximately six months
• Baseline inspections apply to both standard and enhanced post-enhancement
compressors

• The baseline standard for compressor inspections is described Validation Fleet Leaders
in GER-3620 • 6 engineering-identified units applying pre-/early production
— Visual/borescope inspection (annual for most units) enhancement (with or without special instrumentation)
— Major inspection (MI) interval inspections/measurements • These units will be subject to additional inspections/testing
(opening, exposed, closing)
— Unit-specific or condition-based inspections/maintenance

• Inlet system inspections and compressor inlet visual inspections


should be standard practice when accessible. Annual R0 leading
edge mold inspections are a best practice to assist the operator
in monitoring the effects of the compressor inlet air stream. To learn more about this offering, contact your GE sales
representative or visit powergen.gepower.com.

Copyright ©2016 General Electric Company. All rights reserved.


GEA17900B (02/2016) fact sheet