Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Location: Determination of Crack Depth of RCC Sections by Ultrasonic Pulse Meter

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

DETERMINATION OF CRACK DEPTH

OF RCC SECTIONS BY ULTRASONIC


PULSE METER

LOCATION

EQUIPMENT NO.

REFERENCE DESCRIPTION ABRIV UNIT

distance X mm

time cracked tc us

time sound ts us

CALCULATIONS

CONTROLS MANUAL 3.3.8 crack depth d mm


UNIT 11

1113C

MEASURE

200

75

65

58
DETERMINATION OF CRACK DEPTH OF
RCC SECTIONS BY ULTRASONIC PULSE LOCATION
METER

EQUIPMENT NO.

REFERENCE DESCRIPTION ABRIV UNIT

distance X mm

time taken at cracked section tc us

time taken at sound section ts us

CALCULATIONS

velocity at cracked section Vd mm/us

velocity at sound section Vs mm/us

ACI 228.2R EQ 2.7 crack depth d mm

CONTROLS MANUAL 3.3.8 crack depth d mm

crack depth- GOVERNED d mm


UNIT 11

1113C 1113C

MEASURE MEASURE

200 200

75 75

65 65

2.67 2.67

3.08 3.08

27 27

58 58

58 58