Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Pump Performance Datasheet: Operating Conditions Liquid

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Customer : Pump Performance Datasheet

Project name : Encompass 2.0 - 17.2.2.0

Item number : Default Size : PVM(X)5-16


Service : Stages : 16
Quantity :1 Based on curve number : PVM(X)5-16
Quote number : Date last saved : 23 May 2017 12:45 AM
Operating Conditions Liquid
Flow, rated : 7.90 m3/h Liquid type : Water
Differential head / pressure, rated (requested) : 110.0 m Additional liquid description :
Differential head / pressure, rated (actual) : 110.4 m Solids diameter, max : 0.00 in
Suction pressure, rated / max : 0.00 / 0.00 psi.g Solids concentration, by volume : 0.00 %
NPSH available, rated : Ample Temperature, max : 68.00 deg F
Frequency : 60 Hz Fluid density, rated / max : 1.000 / 1.000 SG
Performance Viscosity, rated : 1.00 cP
Speed, rated : 3500 rpm Vapor pressure, rated : 0.34 psi.a
Impeller diameter, rated : PVM(I/X)5-16 Material
Impeller diameter, maximum : PVM(I/X)5-16 Material selected : Not specified
Impeller diameter, minimum : PVM(I/X)5-16 Pressure Data
Efficiency : 64.20 % Maximum working pressure : 228.5 psi.g
NPSH required / margin required : 19.08 / 0.00 ft Maximum allowable working pressure : 360.0 psi.g
nq (imp. eye flow) / S (imp. eye flow) : 34 / 42 Metric units Maximum allowable suction pressure : N/A
Minimum Continuous Stable Flow : 0.68 m3/h Hydrostatic test pressure : N/A
Head, maximum, rated diameter : 160.9 m Driver & Power Data (@Max density)
Head rise to shutoff : 45.72 %
Driver sizing specification : Maximum power
Flow, best eff. point : 6.97 m3/h
Margin over specification : 0.00 %
Flow ratio, rated / BEP : 113.42 %
Service factor : 1.15 (used)
Diameter ratio (rated / max) : 100.00 %
Power, hydraulic : 3.18 hp
Head ratio (rated dia / max dia) : 100.00 %
Power, rated : 4.96 hp
Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
Power, maximum, rated diameter : 5.18 hp
Selection status : Acceptable
Minimum recommended motor rating : 5.00 hp / 3.73 kW (Fixed)
6.0
Power
Power - hp

4.5

3.0

1.5

0.0

200
Minimum Continuous Stable Flow
Preferred operating region
180
Curve efficiencies are typical. For guaranteed values, contact factory
DN15
160 51 56 60
PVM(I/X)5-16 62 DN20
140 64

DN25
120 64
Head - m

62
100 60
56
80

60

40

20

0
NPSHr - ft

30 NPSHr

15

0
0 1 2 3 4 5 6 7 8 9 10 11 12

Flow - m3/h

AURORA PUMP PHONE: +1-630-859-7000 · FAX:


800 AIRPORT ROAD · NORTH
AURORA, ILLINOIS 60542
WWW.AURORAPUMP.COM