Stago Brochure
Stago Brochure
Stago Brochure
Hemostasis Analyzers
The STA® Family of MODELS: AUTOMATED
Hemostasis Analyzers STA-R Evolution® Expert Series: Automation capable, high throughput
STA Compact®: Medium throughput
provides automation of
STA Satellite®: Low throughput
coagulation testing
for a variety of MODELS: SEMI-AUTOMATED
STart®
laboratory situations.
Each system performs FEATURES
Host-query bi-directional interface
clotting, chromogenic Primary tube sampling
and immunoassay Continuous sample access
methodologies in Open reagent system
Reagent and disposable management
random access Reagent level detection
mode. Because all QC management with Levy-Jennings
STA® analyzers use Reagent and sample bar code reader
Auto re-run and auto re-dilute options
the same analysis methods, Programmable and pre-programmed options
and the same reagent Up to 70 on-board reagent capacity
formulations, they offer Capacity of up to 1,000 disposable cuvettes
Multi-constituent controls and calibrator
standardization in
METHODOLOGIES
the laboratory. Clotting – VDS™ Mechanical Clot Detection
Chromogenic – Optical density
Immunological – Optical density
All STA® systems
STA® REAGENT MENU
share the following
PT
characteristics: APTT
Fibrinogen
D-dimer (Quantitative)
Thrombin Time
Reptilase Time
Extrinsic Factors
Intrinsic Factors
Unfractionated Heparin (UFH)
Low Molecular Weight Heparin (LMWH)
Antithrombin (AT) Activity
Protein C Activity (clot-based and chromogenic)
Protein S Activity
Free Protein S Antigen
DRVV Screen and Confirm
VWF Antigen
Plasminogen Activity
Antiplasmin Activity
Fibrin Monomer*
Ribaroxaban*
Lupus Anticoagulants
DRVVT
PTT-LA
Staclot LA
Antithrombin (AT) Antigen
Total Protein S Antigen
Screening Tests......................................................................................................................... 10
Factor Assays............................................................................................................................ 11
Anticoagulants......................................................................................................................... 12
Thrombophilia ........................................................................................................................ 12
Fibrinolysis............................................................................................................................... 16
Primary Hemostasis................................................................................................................. 16
Control Plasmas....................................................................................................................... 17
Calibrators................................................................................................................................ 17
Auxiliary Reagents................................................................................................................... 18
Research Kits........................................................................................................................... 31
Research Components............................................................................................................ 34
Abbreviations.......................................................................................................................... 36
Product Catalog 1
Section.
s
Instruments
CAT. NO. PRODUCT / DESCRIPTION
1
58978 STA-R Evolution® Expert Series Hemostasis System
Automation-Capable, High-Throughput Hemostasis Analyzer
58979 STA-R Evolution® Expert Series Hemostasis System with Cap Piercing
Automation-Capable, High-Throughput Hemostasis Analyzer
Dimensions
Height . . . . . . . . . . . 49.2 inches
Width . . . . . . . . . . . . 50.3 inches
Depth . . . . . . . . . . . . 32.2 inches
Weight . . . . . . . . . . . 564 pounds
Test Selections
200 user definable tests
Samples
215 on-board sample capacity
Primary tube sampling
5 samples per rack
Continuous sample access
LIS Interface
Bi-directional host-query
Automation
Compatible with all major automation vendors
1 Instruments
CAT. NO. PRODUCT / DESCRIPTION
(CONTINUED)
The STA Compact Max® is a fully automated, benchtop hemostasis workstation capable of performing clotting,
chromogenic and immunological assays simultaneously in random access mode. The system’s unique method of
sample management offers moderate throughput and rapid processing of STAT samples without the need to
interrupt current testing. All sample and calibrator dilutions are performed automatically, increasing staff
productivity for laboratories performing moderate-volume routine and specialty coagulation testing.
The STA Compact Max ® takes innovation to the next level by adding state of the art data automation with
the Expert Module software. The combination of VDS methodology and the Expert Module on the STA
Compact Max ® give you complete confidence in the most important part of any analyzer: “The Results”.
Dimensions
Height . . . . . . . . . . . 27,75 inches
Width . . . . . . . . . . . 38.18 inches
Depth . . . . . . . . . . . 28.73 inches
Weight . . . . . . . . . . 309 pounds
Test Selections
80 user definable tests
Samples
96 primary sample tubes onboard
- 84 positions for primary tubes
- 12 positions for pediatric tubes
Continuous sample access
True STAT Managment withouthout impact on throughput
ion
Postive barcode identification
LIS Interface
Bi-directional host-query orr Dynamic Download
4
Section.
s
Instruments
CAT. NO. PRODUCT / DESCRIPTION
(CONTINUED) 1
58104 STA Satellite® Hemostasis System
Fully Automated, Low Throughput Hemostasis Analyzer
Dimensions . . .
Height . . . . . . . . . . . 27.4 inches
Width . . . . . . . . . . . 21.1 inches
Depth . . . . . . . . . . . 25. 5 inches
Weight . . . . . . . . . . 72 pounds
Test Selections
80 user definable tests
Samples
20 on-board sample capacity
Primary tube sampling
Removable sample carousel
Continuous sample loading
Positive sample identification
LIS Interface
Bi-directional host-query
Other Features
Light-emitting diode (LED) for colorimetric assays
Internal barcode reader for samples and reagents
Patented viscosity-based detection system for standard VDS™
Mechnical Clot Detection.
Reagent Menu
PT
APTT
Fibrinogen
AT
Heparin (UFH and LMWH)
D-dimer
STA Satellite®
5
Section
1 Instruments
CAT. NO. PRODUCT / DESCRIPTION
(CONTINUED)
®
58230 STart Hemostasis Analyzer
Benchtop Hemostasis Analyzer for Batch Testing
Dimensions
Height . . . . . . . . . . . 4.7 inches
Width . . . . . . . . . . . 16.1 inches
Depth . . . . . . . . . . . 16.5 inches
Weight . . . . . . . . . . 12.5 pounds
Methodology
Clotting – Standard VDS™ Mechanical Clot Detection
Test Selections
17 test selections
Preprogrammed and programmable options
Other Features
Electronically-linked multiple pipettor
for convenience and accuracy
Internal thermal printer
Four independently-timed incubation
stations with audible signal
Lightweight and compact
Reagent Menu
PT
APTT
Fibrinogen
Thrombin Time
Reptilase Time
Extrinsic Factors
Intrinsic Factors
Protein C Activity
Protein S Activity
PTT-LA
Staclot® LA (Lupus Anticoagulants) STart®
6
Section.
s
27457 Rinsing Plate Assay Air Filter (paper filter) 1 each (STA Compact®)
7
Section
CONTENTS
STA-R Evolution®, STA Compact ® and STA Satellite® Disposables and Accessories (continued)
Miscellaneous Parts
8
Section
3 Screening Tests
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
* ISI values for PT reagents are approximations. Actual ISI values are assigned for each lot of PT reagent.
10
Section.
s
Factor Assays
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
4
00722 STA® - Deficient XII 6 x 1 mL vials
Substrate plasma for Factor XII assay by STA® analyzers.
Freeze-dried human plasma lacking Factor XII.
11
Section
5 Anticoagulants
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
Section
6 Thrombophilia
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
Inhibitors
12
Section.
s
Thrombophilia
CAT. NO. PRODUCT / DESCRIPTION
(CONTINUED)
CONTENTS
6
00596 STA® - Stachrom ® AT III 4 x 3 mL vials of Thrombin
Colorimetric assay of Antithrombin 4 x 3 mL vials of Substrate
activity by STA® analyzers. Bovine 4 x 3 mL vials of Thrombin Solvent
thrombin ~11.3 nKat/mL, freeze-dried.
13
Section
6 Thrombophilia
CAT. NO. PRODUCT / DESCRIPTION
(CONTINUED)
CONTENTS
Lupus Anticoagulants
14
Section.
s
00887 F.S. Test Unit 8 x 0.2 mL vials of F.S. Test Unit Reagent
Stat detection of soluble fibrin 8 x 0.2 mL vials of Positive Control
monomer complexes by 8 x 0.2 mL vials of Negative Control
hemagglutination, 32 tests. 10 - Test Cards
s .
15
Section
8 Fibrinolysis
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
Section
9 Primary Hemostasis
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
16
Section.
s
Control Plasmas
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
10
00381 STA® - Quality HNF/UFH - NEW 6 x 1 mL vials of STA ® Quality HNF/UFH 2
Control plasma for assay of unfractionated heparin (UFH) 6 x 1 mL vials of STA ® Quality HNF/UFH 5
®
using the STA Liquid Anti-Xa method on STA analyzers.
12 Auxiliary Reagents
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
00555 Asserachrom
®
Washing Solution 2 x 50 mL
18
Section.
s
Qualiris is an easy to use, web-based system which provides monthly, biannual, and annual reports with quantitative
and qualitative statistics.
Basic Programs
19
Section
As the Hemostasis market matures, it is characterized by consolidation, automation and an overall shortage of medical
technologists - those who perform the actual work in the lab. Specialists have become generalists, and employee
turnover is high. While the laboratory is evolving, the demand for knowledge and expertise is greater than ever.
SAVORTM (Stago Added Value on Request) is an evolution of our current offerings, customized to meet our customers’
requests for tailored training programs, inventory management and other services. In addition to new programs, we
have evaluated our existing training and modified our approach to provide a more “hands-on” experience. Our
objective is for the lead technologist/key operator to leave the program with a higher level of expertise. As always,
premium service and customer satisfaction remain our highest priority as we adapt our offerings to a changing
laboratory environment.
Please use this section of our catalog as a guide to our expanding service and support offerings. Each item includes a
reference catalog number and detailed description. Your Stago Account Manager can provide additional details related
to logistics and pricing.
The Basic Operator Training course is available for the newly designated “lead technologist” or “key operator” of
Stago instruments or when there is a need to have additional personnel (beyond contract specifications) receive the
training.
20
Section.
s
A member of the Stago Training Team will be assigned to visit the laboratory and conduct the Basic Operator Training.
21
Section
Experienced Operator Training is typically conducted by members of the Field Support Group at the customer’s facility.
The course is conducted by a member of the Stago Training Team at the customer’s facility.
22
Section.
s
The nominal fee is to offset the cost of financing inventory, storage for extended periods and multiple shipments.
Requirements include:
- hard copy purchase order with specified quantity
- shipping schedule including beginning and end dates
Lab Automation
The Evolution can be integrated into a lab automation line. To accomplish the connection, a connection kit and/or
additional accessory items may be required. A Stago automation consultant is available to answer questions and
assure a smooth transition.
ITEM# ACCESSORIES
23
Section
The program is customized to meet the needs of the particular audience. The agenda is composed of a lecture component
and hands-on instrument demonstrations. The specific topics are determined by the participants prior to the event.
PACE credits available.
Method Validation
Standard Service. Stago's standard is to provide customers with in-depth training and tools to perform method validation
as part of our new instrument training program. In this case, your Stago Technical Support Specialist is available via
telephone support to review the protocol, answer questions and provide a final data review.
SAVOR Method Validation Service. We realize that some customers, due to staffing shortages and/or convenience, would
prefer to have a Stago Technical Support Specialist on-site to coordinate and perform method validation. In this case,
the Technical Support Specialist will run the tests, collect data, perform data analysis and provide an electronic data
presentation.
ITEM# DESCRIPTION
Lot Conversion
Lot Conversion/Simple Method Validation (usually a single test parameter)
Lot Conversion. We realize that some customers, due to staffing shortages and/or convenience, would prefer to have a
Stago Technical Support Specialist on-site to perform lot conversion. In this case, the Technical Support Specialist will
run the tests, collect data, perform data analysis and provide an electronic data presentation.
Method Validation. A Stago Technical Support Specialist will be on-site at your hospital for one full day to perform
method validation studies. Prior to arrival, the Technical Support Specialist will work with the lead coagulation
technologist/key operator to develop the plan for sample requirements and time management. The Technical
Support Specialist will schedule a time to be present to run samples, generate data and complete the process.
24
Section.
s
Instrument Decommission
A Stago Field Service Engineer will decontaminate your retired coagulation instrument and remove the hard drive in
compliance with regulatory and HIPAA requirements. This program applies to Stago manufactured instruments only
and is performed while the Stago Field Service Engineer in on-site for another reason.
85077 Decommission
25
Section
Instrument
86186 Calibrated Automated Thrombogram® Thermo Electron Fluoroskan Ascent Analyzer
The Calibrated Automated Thrombogram ® (CAT) Computer
measures the concentration of thrombin Thrombinoscope Software
generation over time in clotting plasma Operator’s reference manual
using either platelet poor or platelet rich Dongle
plasma. The CAT corrects for substrate Filters: 1 – 390nm, 1– 460nm
consumption, the inner filter effect and
color differences between plasmas by running
a calibrator with every patient sample. The
CAT provides a description of hyper as well
as hypo-activity of the clotting system.
Reagents
86192 Thrombin Calibrator 20 x 16 tests
Corrects for individual differences in color of plasma,
inner filter effect and substrate consumption, which is
necessary for use in parallel with each sample.
Disposables
26
Section
s
01053 ECA Hirudin Control 3 x 2 mL ECA-H Control (0.9 μg/mL - 1.1 μg/mL)
Hirudin Control for ECA-H kit.
01055 ECA Argatroban Control 3 x 2 mL ECA-T Control Argatroban Low (0.4 μg/mL -
Argatroban Control for the ECA-T kit. 0.6 μg/mL)
3 x 2 mL ECA-T Control Argatroban High (1.7 μg/mL -
2.3 μg/mL)
01057 ECA Bivalirudun Control 3 x 2 mL ECA-T Control Bivalirudin 10 μg/mL (8.6 μg/mL -
Bivalirudin Control for the ECA-T kit. 11.4 μg/mL)
27
Section.
s
PLT Gp/Receptors kit allows precise quantitation of GpIIb, GpIbα and GMP140 glycoproteins on
platelet surface, at the resting state and after TRAP (Thrombin Receptor Agonist Peptide) activation
for detection of constitutive thrombopathies, including Glanzmann Thrombasthenia, Bernard Soulier
syndrome, Fechtner syndrome, X-linked thrombocytopenia, and Gray platelet syndrome.
Single color flow cytometric analysis of the GpIIb/IIIa glycoprotein receptor for testing of occupancy
by various anti-GpIIb/IIIa drugs including abciximab (Reopro®), eptifibatide (Integrilin®), or tirofiban
(Aggrastat®).
Single color flow cytometric analysis of the platelet glycoproteins GpIIIa, GpIb and GpIa.
For analysis of a a platelet glycoprotein polymorphism in the HPA system (Human Platelet Antigens).
For standardizing microparticle setup within a given analysis region (0.5-1 μm) and providing setting stability.
For responsive testing of specific platelet ADP receptor (P2Y12) antagonists, including clopidogrel (Plavix®),
prasugrel (Effient®), and ticagrelor (Brilinta®).
For dual color flow cytometric analysis of Platelet Associated Immunoglobulins (PAIg).
Calibration kit for the measurement of platelet glycoprotein expression level or any other human platelet
surface molecules.
For analysis of deficiencies of CD55 and CD59 on the granulocyte surface for the purpose of analyzing
samples from patients suspected of Paroxysmal Nocturnal Haemoglobinuria (PNH).
Calibration kit for the measurement of human leukocyte surface antigen expression level by multiple color analysis.
For analysis of deficiencies of CD55 and CD59 on the red blood cell surface for the purpose of analyzing samples
from patients suspected of Paroxysmal Nocturnal Haemoglobinuria (PNH).
29
Section
30
Section .
s
Section
Research Kits
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
18
(Research Use only, not for diagnostic procedures)
32
Section.
Research Kits (CONTINUED)
(Research Use only, not for diagnostic procedures)
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
18
®
00276 Asserachrom Soluble GPV 3 x 2 Coated Strips
Quantitative determination of 3 x 8 mL vials of Anti-sGPV-Peroxidase
soluble Glycoprotein V by 3 x 8 mL vials of TMB
ELISA method, 96 tests. 3 x 50mL bottles of Dilution Buffer
1 x 50 mL bottle of Washing Solution
3 x 0.5 mL vials of sGPV Calibrator
3 x 0.5 mL vials of sGPV Control
1 Plate Frame; 1 Plate Cover
® ®
00543US STA Liatest FM 6 x 2 mL vials of Buffer
Immuno-turbidimetric assay of Fibrin Monomer by STA® 6 x 4 mL vials of Latex
Monomer by STA ® analyzers. Microlatex particles coated 90 tests
with two different mouse monoclonal anti-human fibrin
monomer antibodies, 90 tests.
®
00544US STA FM Calibrator 2 x 1 mL vials of calibrator 1
A set of calibrator plasmas intended for calibration of 2 x 1 mL vials of calibrator 2
fibrin monomers present or not present in soluble 2 x 1 mL vials of calibrator 3
complexes by the immunoturbidimetric method. 2 x 1 mL vials of calibrator 4
2 x 1 mL vials of calibrator 5
®
00545US STA FM Control 6 x 1 mL vials of control 1
Two plasmas intended for the quality control of assays 6 x 1 mL vials of control 2
of fibrin monomers present or not present in soluble
complexes by the immunoturbidimetric method
33
Section
18 Research Kits
(Research Use only, not for diagnostic procedures)
®
00704US STA Rivaroxaban Calibrator 3 x 1 mL vials of Calibrator 1
Calibration plasmas for rivaroxaban measurement using 3 x 1 mL vials of Calibrator 2
chromogenic anti-Xa Method 3 x 1 mL vials of Calibrator 3
3 x 1 mL vials of Calibrator 4
®
00706US STA Rivaroxaban Control 3 x 1 mL vials of Control 1
Control plasmas for rivaroxaban measurement using 3 x 1 mL vials of Control 2
chromogenic anti-Xa Method
®
00853 Stachrom PAI 2 x 2 mL vials of Urokinase
Chromogenic assay of plasminogen 2 x 2 mL vials of Plasminogen
activator inhibitor activity, 20 tests. 2 x 2 mL vials of Substrate
2 x 0.5 mL vials of PAI Calibrator 1
2 x 0.5 mL vials of PAI Calibrator 2
2 x 0.5 mL vials of PAI Calibrator 3
Research Kits(cont.)
(Research Use only, not for diagnostic procedures)
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
18
01074 STA Apixaban Control 3 x 1 mL vials of Control 1
3 x 1 mL vials of Control 2
.
01075 STA Apixaban Calibrator 3 x 1 mL vials of calibrator 1
3 x 1 mL vials of calibrator 2
3 x 1 mL vials of calibrator 3
3 x 1 mL vials of calibrator 4
19
1 plate frame
Research Components
(Research Use only, not for diagnostic procedures)
CAT. NO. PRODUCT / DESCRIPTION CONTENTS
Purified Proteins a
00463 Purified Heparin Cofactor II 1 Plasma Equivalent Units (PEU), approx 100 μg
Chromogenic Substrates b
00811 CBS 31.39 (Substrate for Factor Xa) 1 vial, 7.5 μMoles
00820 Aprotinin (Kunitz Protease Inhibitor) 6 vials, each approximately 10 PEU, 1 PEU = 1,800
kallikrein inhibitor units (KIU)
Abbreviations
ABBREVIATION NAME ABBREVIATION NAME
36
Coagulation Cascade
Terms and Conditions of Sale
FOR REAGENTS, DISPOSABLES & ACCESSORIES
Definitions: Sequestering:
Products: Reagents, Disposables and Accessories as defined Reagents to be sequestered (by storing a pre-established
in DSI's Product catalog in force from time to time. quantity of a single lot of Reagent) are determined by DSI based
DSI: Diagnostica Stago, Inc., a Delaware corporation on Customer’s sequestering request. Sequestering will require a
with its principal place of business at Five Century hard copy Purchase Order indicating line item quantity and a
Drive, Parsippany, NJ 07054, the seller of the specified delivery schedule including beginning and end dates.
Products. First delivery of sequestered Reagents cannot be less than 30
Customer: The person or entity purchasing the Products. days from the date of the sequestering request.
38
Main Index
Item Page(s) Item Page(s)
39
Main Index (continued)
Item Page(s) Item Page(s)
40
DIAGNOSTICA STAGO, Inc.
Five Century Drive . Parsippany, N J 07054
800.222.COAG
973.631.1200
973.631.1618 (fax)