Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

LV MaxSonar EZ1 Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

® ™

LV-MaxSonar -EZ1
® Data Sheet
LV-MaxSonar -EZ1™ G F C

High Performance N
GND

Sonar Range Finder +5


TX B
®
With 2.5V - 5.5V power the LV-MaxSonar - RX
E

EZ1 provides very short to long-range AN
detection and ranging, in an incredibly PW
brown
dot
® ™
small package. The LV-MaxSonar -EZ1 *BW M
H
D
detects objects from 0-inches to 254-inches L
A
(6.45-meters) and provides sonar range
*Brown dot parts enhanced for low noise chaining
information from 6-inches out to 254-inches
K A 0.785" 19.9 mm H 0.100" 2.54 mm
with 1-inch resolution. Objects from 0- B 0.870" 22.1 mm J 0.645" 16.4 mm
inches to 6-inches range as 6-inches. The C 0.100" 2.54 mm K 0.610" 15.5 mm
D 0.100" 2.54 mm L 0.735" 18.7 mm
interface output formats included are pulse E 0.670" 17.0 mm M 0.065" 1.7 mm
J
width output, analog voltage output, and approximately
F 0.510" 12.6 mm N 0.038" dia. 1.0 mm dia.
G 0.124" dia. 3.1 mm dia. weight, 4.3 grams
serial digital output. actual size
values are nominal

Features Benefits Beam Characteristics


• Continuously variable gain  Very low cost sonar People detection requires high sensitivity, yet a
for beam control and side ranger narrow beam angle requires low sensitivity. The
lobe suppression  Reliable and stable LV-MaxSonar-EZ1 balances the detection of
• Object detection includes range data people with a narrow beam width.
zero range objects  Sensor dead zone Sample results for measured beam patterns are
• 2.5V to 5.5V supply with virtually gone shown below on a 12-inch grid. The detection
2mA typical current draw  Lowest power ranger pattern is shown for;
• Readings can occur up to  Quality beam (A) 0.25-inch diameter dowel, note the narrow beam
every 50mS, (20-Hz rate) characteristics for close small objects,
• Free run operation can  Mounting holes (B) 1-inch diameter dowel, note the long narrow
provided on the detection pattern,
continually measure and
output range information circuit board (C) 3.25-inch diameter rod, note the long controlled
 Very low power detection pattern,
• Triggered operation provides (D) 11-inch wide board moved left to right with
the range reading as desired ranger, excellent for
multiple sensor or the board parallel to the front sensor face and
• All interfaces are active the sensor stationary. This shows
battery based D
simultaneously the sensor’s range capability.
systems
• Serial, 0 to Vcc - 20 ft.
 Can be triggered Note: The displayed beam width of (D) is
• 9600Baud, 81N a function of the specular nature of sonar
externally or
• Analog, (Vcc/512) / inch internally and the shape of the board (i.e.
- 15 ft.
• Pulse width, (147uS/inch)  Sensor reports the
flat mirror like) and should
never be confused with C
• Learns ringdown pattern range reading actual sensor
when commanded to start directly, frees up beam width. B - 10 ft.
ranging user processor 5V
• Designed for protected  Fast measurement 3.3V
indoor environments cycle A - 5 ft.
• Sensor operates at 42KHz  User can choose any
• High output square wave of the three sensor
sensor drive (double Vcc) outputs
beam characteristics are approximate
® Data Sheet Release: 04/26/10, pg. 1
MaxBotix
EZ0
Inc.
MaxBotix, MaxSonar & EZ1 are trademarks of MaxBotix Inc. Email: info@maxbotix.com
LV-EZ1™ • v3.0c • 07/2007 • Copyright 2005 - 2010 Web: www.maxbotix.com
® ™
LV-MaxSonar -EZ1
®
LV-MaxSonar -EZ1 Pin Out
™ Data Sheet, pg. 2
® ™
GND – Return for the DC power supply. GND (& Vcc) must be LV-MaxSonar -EZ1 Circuit
ripple and noise free for best operation. ® ™
The LV-MaxSonar -EZ1 sensor functions using
+5V – Vcc – Operates on 2.5V - 5.5V. Recommended current active components consisting of an LM324, a diode
capability of 3mA for 5V, and 2mA for 3V. array, a PIC16F676, together with a variety of
TX, – When the *BW is open or held low, the TX output delivers passive components.
asynchronous serial with an RS232 format, except voltages are 0-
Vcc. The output is an ASCII capital “R”, followed by three ASCII
character digits representing the range in inches up to a maximum
of 255, followed by a carriage return (ASCII 13). The baud rate is
9600, 8 bits, no parity, with one stop bit. Although the voltage of 0-
Vcc is outside the RS232 standard, most RS232 devices have
sufficient margin to read 0-Vcc serial data. If standard voltage
level RS232 is desired, invert, and connect an RS232 converter
such as a MAX232.
*Brown dot parts: When BW pin is held high the TX output
sends a single pulse, suitable for low noise chaining (no serial data).

RX – This pin is internally pulled high. The EZ1 will continually
measure range and output if the RX pin is left unconnected or held

high. If held low the EZ1 will stop ranging. Bring high 20uS or
more for range reading.
AN – Outputs analog voltage with a scaling factor of (Vcc/512) per
inch. A supply of 5V yields ~9.8mV/in. and 3.3V yields
~6.4mV/in. The output is buffered and corresponds to the most
recent range data.
PW – This pin outputs a pulse width representation of range. To
calculate distance use the scale factor of 147uS per inch.
BW – *Leave open or hold low for serial output on the TX output.
*Brown dot parts: When BW pin is held high the TX output
sends a pulse (instead of serial data), suitable for low noise chaining.
® ™
LV-MaxSonar -EZ1 Timing Description
® ™
250mS after power-up, the LV-MaxSonar -EZ1 is ready to accept the RX command. If the RX pin is left open or
held high, the sensor will first run a calibration cycle (49mS), and then it will take a range reading (49mS). Therefore, the
® ™
first reading will take ~100mS. Subsequent readings will take 49mS. The LV-MaxSonar -EZ1 checks the RX pin at the
end of every cycle. Range data can be acquired once every 49mS.
® ™
Each 49mS period starts by the RX being high or open, after which the LV-MaxSonar -EZ1 sends thirteen 42KHz
waves, after which the pulse width pin (PW) is set high. When a target is detected the PW pin is pulled low. The PW pin is
high for up to 37.5mS if no target is detected. The remainder of the 49mS time (less 4.7mS) is spent adjusting the analog
voltage to the correct level. When a long distance is measured immediately after a short distance reading, the analog
voltage may not reach the exact level within one read cycle. During the last 4.7mS, the serial data is sent. The LV-
® ™
MaxSonar -EZ1 timing is factory calibrated to one percent at five volts, and in use is better than two percent. In
addition, operation at 3.3V typically causes the objects range, to be reported, one to two percent further than actual.
® ™
LV-MaxSonar -EZ1 General Power-Up Instruction
® ™
Each time after the LV-MaxSonar -EZ1 is powered up, it will calibrate during its first read cycle. The sensor uses this
stored information to range a close object. It is important that objects not be close to the sensor during this calibration
cycle. The best sensitivity is obtained when it is clear for fourteen inches, but good results are common when clear for at
least seven inches. If an object is too close during the calibration cycle, the sensor may then ignore objects at that distance.
® ™
The LV-MaxSonar -EZ1 does not use the calibration data to temperature compensate for range, but instead to
compensate for the sensor ringdown pattern. If the temperature, humidity, or applied voltage changes during operation, the
sensor may require recalibration to reacquire the ringdown pattern. Unless recalibrated, if the temperature increases, the
sensor is more likely to have false close readings. If the temperature decreases, the sensor is more likely to have reduced up
® ™
close sensitivity. To recalibrate the LV-MaxSonar -EZ1 , cycle power, then command a read cycle.
Product / specifications subject to change without notice. For more info visit www.maxbotix.com/MaxSonar-EZ1_FAQ
® Data Sheet Release: 04/26/10, pg. 2
MaxBotix Inc.
MaxBotix, MaxSonar & EZ1 are trademarks of MaxBotix Inc.
Email: info@maxbotix.com
Web: www.maxbotix.com
LV-EZ1™ • v3.0c • 07/2007 • patent 7,679,996

You might also like